HomeMy WebLinkAboutFISCHER PROPERTIES - FDP230010 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLAN (2)SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI
HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 8` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 10` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER PROS-06-PRS30-CV 15` RADIUS
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
30
HUNTER RZWS-18-CV
18IN. LONG RZWS WITH INSTALLED NO BUBBLER. INSTALL
WITH CHECK VALVE, 1/2IN. SWING JOINT FOR CONNECTION
TO 1/2IN. PIPE. INSTALL WITH RAINBIRD XB-05PC EMITTER
PER DETAILS.
30
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
RAIN BIRD XCZ-100-PRB-COM
WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL
APPLICATIONS. 1" BALL VALVE WITH 1" PESB VALVE AND 1"
PRESSURE REGULATING 40PSI QUICK-CHECK BASKET
FILTER. 0.3 GPM-20 GPM
DRIP FLUSH VALVE
3/4" PVC BALL VALVE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER ICV-G-FS: 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC
REMOTE CONTROL VALVES, GLOBE CONFIGURATION, WITH
NPT THREADED INLET/OUTLET, FOR
COMMERCIAL/MUNICIPAL USE. WITH FILTER SENTRY.
QUICK COUPLER ASSEMBLY
RAIN BIRD 5-RC: 1" BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING,
THERMOPLASTIC RUBBER COVER, AND 1-PIECE BODY.
ISOLATION GATE VALVE ASSEMBLY
MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL
PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE
AS MAINLINE PIPE.
MASTER VALVE ASSEMBLY
BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER
VALVE THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO
MATCH POC
REDUCED PRESSURE BACKFLOW PREVENTER
FEBCO 825YA: SIZED TO MATCH POC METER SIZE. REDUCED
PRESSURE BACKFLOW PREVENTER IN STRONG BOX
SBBC-30AL: LOW PROFILE BACKFLOW ENCLOSURE, WITH
MARINE GRADE ALUMINUM. 30"L, 30"H, 16.25"W (76.2CM L,
76.2CM H, 41.275CM W).
PEDESTAL MOUNT TRADITIONAL
HUNTER A2C-2400-SS: 24-STATION CONTROLLER WITH TWO
(2) A2M-600 MODULES IN AN OUTDOOR STAINLESS STEEL
WALL MOUNT ENCLOSURE. INSTALL WIRELESS RAIN
SENSOR AND SOLAR SYNC
PEDESTAL MOUNT TRADITIONAL
HUNTER A2C-2400-SS: 24-STATION CONTROLLER WITH TWO
(2) A2M-600 MODULES IN AN OUTDOOR STAINLESS STEEL
WALL MOUNT ENCLOSURE. INSTALL WIRELESS RAIN
SENSOR AND SOLAR SYNC
CREATIVE SENSOR TECHNOLOGY FSI-T
1" PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM
MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER
ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL
OUTPUT. FLOW RANGE: .86-52 GPM.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL
TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED
ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE.
IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION
LATERAL LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE
PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER
CHART.
IRRIGATION LATERAL LINE: NATIVE PLANTING DRIP
IRRIGATION LATERAL LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE
PIPE TO TREE RINGS, NETAFIM INLINE DRIP TUBING
MODEL TLCV6-18, AND SINGLE OUTLET EMITTERS FOR
SHRUBS PER ADJACENT EMITTER CHART
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
X-INCH UNLESS OTHERWISE NOTED
PIPE SLEEVE: PVC SCHEDULE 40
INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE
PIPE OR WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE
BUNDLES SHALL SHARE THE SAME SLEEVE.
A
B
IRRIGATION_SCHEDULE INSTALLATION GENERAL NOTES
1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION
SYSTEM (PER CITY OR ENGINEER / NOT OBTAINED) OF XX PSI, AT A MAXIMUM PEAK FLOW
OF 10 GPM AT THE 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW
ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S
REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE.
2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE
POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK
SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS.
3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE
INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP.
4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND
INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR
CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION.
4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED
ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND
BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE
VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS.
4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS
PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF
EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM,
ETC.
5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION ("811-CALL BEFORE YOU DIG") .
6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND
PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR
GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF
THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED
DESIGN, DETAILS, OR SPECIFICATIONS.
7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE
INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION
COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY.
8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND
ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION
OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO
SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL
SPRINKLERS MAY BE REQUIRED.
8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE
AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE
ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN
WITHIN THE 3'-5' RANGE NOTED ABOVE.
9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS.
10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA
CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE
REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION
DESIGNER FOR APPROVAL.
11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO
CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL
BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH
PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE
INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES
BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE
HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR.
12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL
ELECTRIC UTILITY CODES.
13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF
UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED
PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE
SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND.
13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG
IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND
MAY NOT BE THE LARGEST SIZE ON PLANS.
14.INSTALL THREE (3) #14 AWG CONTROL WIRES FROM CONTROLLER LOCATION TO
EACH DEAD-END OF MAINLINE FOR USE AS SPARES INCASE OF CONTROL WIRE FAILURE.
COIL 3 FEET OF WIRE IN VALVE BOX.
15.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR
TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS
ARE IRRIGATED ON DRIP SYSTEM.
16.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.
17.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT
UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND
ESTABLISHMENT.
18.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES,
AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION.
EMITTER SCHEDULE
PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW
GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH
PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH
1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH
5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH
TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH
TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A
NOTES:
1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB
BEDS.
2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS.
SYMBOL DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE DEDICATED IRRIGATION WATER TAP AND
METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL
PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION
UNIT, MASTER VALVE, AND FLOW SENSOR ASSEMBLY AS
INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S
REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO
CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER
NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW
SHALL BE TESTED UPON INSTALLATION AND ANNUALLY
THEREAFTER.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY
WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL
LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE.
CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE.
1
2
REFERENCE NOTES SCHEDULE
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR1.0 Printed On: 9/6/2023 11:57 AM File Name: IR-FISCHER PROPERTY.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
IRRIGATION LEGEND
AND NOTES
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR1.0
NORTH
0 10 20 40
SCALE: 1"=20'-0"
/ / / / / / / // / / / / / / // / / / / / / /W W W W W W W W W W W W W W W W UDUDUDUDSS
WWWWWWWWWWWWWW
WWWW
WWWW
WWW
WWW
S
S
SSS
SSSSWHY DSS SS
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRRCONTROL
IRRCONTROL
IRRCONTROL
IRR
W
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHUOHUOHU OHU
E
SS SS SS
SSSSSSSSSSSSSSSSW
E
E
EEEEGGGGGGGGGGGGGGGGGW
FO FO FO
W
S
POC NO.1
TAP & METER SIZE: 3/4-INCH
PEAK DEMAND: 10 GPM
AVAILABLE PRESSURE: X PSI
-OR-
REQUIRED PRESSURE: X PSI
CONTROLLER 'A'
120 VAC POWER REQUIRED
1
2
(3)3"
DRIVEDEL MAR STREETM
A
(3)3"(3)3"
(3)3"(3)3"
(3)3"
(3)3"
(2)2"
(2)2"
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR1.1 Printed On: 9/6/2023 11:57 AM File Name: IR-FISCHER PROPERTY.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
IRRIGATION PLAN
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR1.1
NORTH
0 10 20 40
SCALE: 1"=20'-0"MATCHLINE - SEE SHEET IR1.2
WWWWUDUDUD UD UD UD UD UD UD UD
SS
SS
GAS
WSG G G GGGGGGWWWWNYLO
PLASTDO NOT
PO
LL
UT
EDRAIN
S
TOWATERW
AYS
DO NO
T
P
OL
L
UT
E
DR
A
IN
S
TO
W
A
TE
RW
AY
S NYLOPL
AS
T
D
U
CT
I
LE
I
RO
NNYLO
PLASTDO NOT
PO
LL
UT
E
DRA
I
NS
T
OWATERW
AYS
DO NOT
PO
L
LU
TE
D
R
AI
N
S
T
O
WA
T
ER
WA
YS NYLOPL
AS
T
D
U
CT
I
LE
I
RO
N
DS
DS
DS
DS
DS
DS
DS DS
DS
DS
DS DS
DS
DS
DS
DS
DS DS
DS DS DS DS
DS
DS
DS
DS
DS
DS
DS
DS
DSDS
DS
DS
DS
DS
DS
DS
DS
DS
NYLOPLASTDO NOT POLLUTEDRAIN
S
T
O
WATE
R
W
A
Y
S
DO NO
T
P
O
L
L
U
T
E
D
R
A
I
N
S
T
O
W
A
T
E
R
W
A
Y
S
NYLOP
L
A
S
T
D
U
C
T
I
L
E
I
R
O
N WWWWWWFW S
OW S
OW S
OWS
OW S
OWS
OWS
OW
D
D
D
D
D
ST
S SS SSSS
STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS
T
S
T
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTSTGGGGGGGGGGGEEEEEEEEEEEEEEEOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
E
E
E
E
E E E
WW
W W W W W W
W W
W W
WWWWWWWWWWWWWWWWWWWWWWWEEWE
E
E
E
E E E E E E
G
G
G
G
G
G G G G G G G G G G G G G
FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOE E E E E E E E E E E E
E
E E EEEWC S
W
W
W
D
D
C SCS
FO
FO
FO FO
FOFOM
B
POC NO.2
TAP & METER SIZE: 3/4-INCH
PEAK DEMAND: 10 GPM
AVAILABLE PRESSURE: X PSI
-OR-
REQUIRED PRESSURE: X PSI
CONTROLLER 'B'
120 VAC POWER REQUIRED
1
2
(3)3"
(3)3"
(2)2"
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR1.2 Printed On: 9/6/2023 11:57 AM File Name: IR-FISCHER PROPERTY.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
IRRIGATION PLAN
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR1.2
NORTH
0 10 20 40
SCALE: 1"=20'-0"MATCHLINE - SEE SHEET IR1.1
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR2.1 Printed On: 9/6/2023 11:57 AM File Name: IR-FISCHER PROPERTY.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
IRRIGATION DETAILS
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR2.1
NORTH
0 10 20 40
SCALE: 1"=20'-0"
MASTER VALVE
ASSEMBLY2 ISOLATION GATE VALVE
ASSEMBLY4
QUICK COUPLING VALVE
ASSEMBLY5 REMOTE CONTROL TURF
VALVE ASSEMBLY6 6-INCH GEAR-DRIVEN
ROTOR ASSEMBLY7 6-INCH POP-UP SPRAY
SPRINKLER ASSEMBLY8
FLOW SENSOR
ASSEMBLY3BACKFLOW PREVENTION
UNIT1
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR2.2 Printed On: 9/6/2023 11:57 AM File Name: IR-FISCHER PROPERTY.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
Erik Fischer
125 S. Howes St. Suite 900
Fort Collins, CO 80521
p. 970.372.6396
ENGINEER
ARCHITECT
LAND PLANNER / LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Danny Weber
301 N. Howes Street, Suite 100
Fort Collins, CO 80521
p. 970.221.6789
VFLA ARCHITECTURE + INTERIORS
Jeff Fleischer
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.1191
OWNER
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
1 FDP 03/15/23
2 FDP 09/06/23
IRRIGATION DETAILS
DESIGN
DEVELOPMENT
FISCHER PROPERTIES
FORT COLLINS, CO
TEAM
MLP
R16-057.1
IR2.2
NORTH
0 10 20 40
SCALE: 1"=20'-0"
REMOTE CONTROL DRIP
VALVE ASSEMBLY9 SINGLE OUTLET EMITTER
ASSEMBLY10
TYPICAL TRENCHING
DETAIL15
DRIP FLUSH CAP
ASSEMBLY12
TYPICAL SLEEVING
DETAIL14
24" min.
INLINE DRIP PIPE ASSEMBLY
FOR TREES IN NATIVE 11
PEDESTAL MOUNT CONTROLLER
ASSEMBLY13
A