Loading...
HomeMy WebLinkAbout611 LAPORTE AVE - CARRIAGE HOUSE - FDP230018 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS7.176.84 7.577.797.58WSV WSV WSV WSV WSV WSV WSV WSV WSV WSV WSV WSV WSV SSVSSVSSVWSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVSSVS E E E E E E GGGGGGXXXXXXXXXXXXXXXXXXX X X X OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUVAULTCABLECABLEVAULTF.O.CSV.P.SSSSSSSSSSSSSSSSSSSSSSSS12" W12" W12" W12" W12" W12" WWSV WSV WSV WSV WSV WSV WSV EEEEEEEEEEEEEESSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSV SSVSSVSSVSSVSSVSSVSSV SSV (7.87)(7.79)(7.80)(7.82)(7.73)(7 . 7 8 )(7.23)(7.41)(6.14)(6.16)6. 2 2 6.247.247.237.287.11(7.18)7.44 7.717.947.747. 5 8 7.617. 9 1 6. 5 8 (7.36)7.28(7.34)7.32(7.47)7.847.84FFE=8.298.298.128.128.267.84 7.93 7.977.677.817.748.288.288.28 8.288.208.2 8 8.21 8.047.64???7.137.917.867.747.957.737.507.3 97.26(7.60)(7. 4 4 )(7.56)(7.78)(7.94)(7.97)(8.01)7.667.34(7.30)(7.35)(7.24)7.19(7.73)(7.67)(7.35)7.31(8.11)7.49(7.55)(7.55)(7. 5 8 )(7.57)7.508.128.127.6%0.5%7.0%1.9%7. 3 % 0.7% 8" DROP IN GRATE INLET ON RISER PIPE INV EL.=6.53 7.5 LF 4" STRM @ 0.50% 9" SQUARE YARD DRAIN INLET INV EL.=6.42 2' CURB CUT AND SIDEWALK CHASE PER FOCO DETAIL 6.5 LF. 4" ROOF LEADER 7.5 LF 4" ROOF LEADER 7.5 LF 4" ROOF LEADER 6.5 LF 4" ROOF LEADER 1.8%1.8%1.4%1.6%3.7%2 . 9%2.5%3.0%6.6%3.6% 1.5% 3. 0 %2.2%2. 2 % 5.3% 1.7 %0.7%0 . 7%8.0%5.1%15.2%1.2% 4. 3 % 1.5 %8:16:12.0%2.0%2.0%6.0% 0.8% 2.0% FFE=8.28 9" SQUARE YARD DRAIN INLET INV EL.=6.32 4" DROP IN GRATE INLET INV EL.=6.61 6" C/O INV EL.= 6.39 45° BEND W/ 6" C/O INV EL= 6.29 (7.70)(9.24)(7.67)(7.55)7.29 7.377.19DAYLIGHT 6" PIPE INTO 3' LONG HEADWALL 6" MIN THICKNESS #4 REBAR 2.5" CLEAR ALL WAYS. FOOTER MIN 18" BELOW GRADE 2 4 .9%5.6%4.1%4.1%2.1%3 . 3%2.1%(7. 3 0 ) (7. 3 6 )7.907.617.57REGRADE AND REPLACE GRAVEL PARKING7.73GARAGE 1" DEPTH PAN IN DRIVEWAY @1' FROM GRAVEL GRADE 1' INSIDE PROPERTY LINE TO DRAIN 7. 2 8 7. 2 1 7.07 7. 2 9 7. 3 4 7. 1 9 7.85 2.8%10.3%115 LF. 4" PVC SANITARY SERVICE @ 2% MIN 96 L.F. 3/4" UNDERGROUND GRADE PEX WATER SERVICE @ MIN 4' BURY S00°23'30"W 167.47'S89°50'29"E 60.14'N00°22'53"E 167.46' TAP EXISTING SERVICE 4" TAP EX. MAIN ABANDON EX. TAP PER FOCO REQ.15.5'N89°49'38"W 60.12'5'10'REGRADE AND REPLACE FLAGSTONE 6" C/O INV. EL=6.48 4" C/O 102 LF 6" STRM @ 0.20% 24 LF 6" STRM@ 0.20%LAPORTE AVEALLEYEXISTING BUILDING COVERED SLAB ENCLOSED BUILDING 4' WALK 12.09'6.83'27.42'22.62'23 LF 4" STRM @ 0.20% 8 LF 4" STRM @ 0.20% 4" SANITARY CLEANOUT 4" WYE W/ 2X SANITARY CLEANOUT (EACH WAY) CONNECT ELECTRIC TO METER AND PANEL (DESIGN BY OTHERS) CONNECT TO GAS (DESIGN BY OTHERS) 36 LF 4" STRM @ 0.20% 10.5 LF 4" STORM @ 0.20% 43 LF 4" STORM @ 0.20% REMOVE SAN SERVICE AS NEEDED 17.32'30.37'4' WALK EXISTING TREE LOCATIONS. PROTECT WHERE POSSIBLE 1.0% 4" PVC MITERED DRAIN w/ HDPE GRATE INV EL.=6.58 4" DROP IN GRATE INLET INV EL.=6.58 SheetLOT 4, BLOCK 271 SUBDVISIOIONNOT FOR CONSTRUCTIONREVIEW SETof 1611 LAPORTE, FORT COLLINS1 SITE DEVELOPMENT PLANCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet01010 10 20 30 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.ALL STORM (STRM) IS DUAL WALL HDPE OR PVC W/ CORRESPONDING SOIL TIGHT FITTINGS AND BENDS. USE WYE AND EXTENSION FOR ALL STRM CLEANOUTS. ALL BENDS AND WYES 45°. 6.USE SCREENED AUTO-CLEAN ADS DOWNSPOUT ADAPTORS AT ALL ROOF DRAIN CONNECTIONS. 7.INSTALL TRACER WIRE WITH ALL UNDERGROUND PIPE INSTALLATIONS 8.USE STANDARD CITY OF FORT COLLINS UTILITY STANDARDS AND SPECIFICATIONS FOR ALL WATER AND SEWER MATERIALS . NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK