Loading...
HomeMy WebLinkAboutJEROME STREET STATION - FDP230006 - SUBMITTAL DOCUMENTS - ROUND 4 - SITE PLANDRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: COVER SHEET Printed On: 7/26/2023 10:50 AM File Name: COVER.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER COVER SHEET FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 1 OF 32 JEROME STREET STATION FINAL DEVELOPMENT PLAN SITE PLAN NOTES 1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6.A MODIFICATION REQUEST FOR INCREASED LENGTH OF A MAJOR WALKWAY SPINE LUC 3.5.2(D) IS ATTACHED WITH THIS SITE PLAN. 7.A MODIFICATION REQUEST FOR STREET FACING FACADES LUC 3.5.2(D)(2) IS ATTACHED WITH THIS SITE PLAN . 8.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 9.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 10.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 11.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 12.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 13.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 14.DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER. 15.THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT OR HOME OWNER'S ASSOCIATION (HOA) IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 16.PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 17.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 18.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND Revised November 12, 2015 3 LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 19.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. 20.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100 YEAR AND 500 YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. 21.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES, SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK, LANDSCAPING, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS. 22.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED USE STRUCTURES IS PROHIBITED IN THE POUDRE RIVER 100 YEAR FLOODPLAIN. 23.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER PERMANENT OR TEMPORARY IS PROHIBITED IN THE YEAR FLOODPLAIN. 24.AT RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100 YEAR FLOODPLAIN. 25.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE ISSUED FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A LOMR IS APPROVED THROUGH FEMA. IT IS AT OUR OWN RISK THAT WE CONTINUE THROUGH THE PLANNING PROCESS. 26.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 27.AS THIS IS PART OF THE REGIONAL TRAIL SYSTEM, THE CITY IS RESPONSIBLE FOR THE LONG-TERM MAINTENANCE OF THE COMMUNITY TRAIL WITHIN THE DEVELOPMENT. MAINTENANCE CONSISTS OF SNOW PLOWING OF THE PAVED SURFACE, OCCASIONAL SEASONAL MOWING 23' ADJACENT TO THE TRAIL SURFACE, REPAIRING/REPLACING SURFACE DAMAGE OF THE TRAIL. ALL OTHER LANDSCAPING MAINTENANCE WITHIN THE EASEMENT IS THE RESPONSIBILITY OF THE UNDERLYING PROPERTY OWNER. LANDSCAPING SHALL BE DESIGNED IN ACCORDANCE WITH ALL APPLICABLE CITY CODES AND PLEASE COORDINATE WITH THE CITY'S PARKS DEPARTMENT. SPRAY IRRIGATION, IF REQUIRED, SHALL BE DESIGNED AND MAINTAINED TO AVOID SPRAY ON THE TRAIL. NORTH SCALE: 1" = 1200' SITE E. SUNIGA ROADN. COLLEGE AVE.N. COLLEGE AVE.W. MOUNTAIN AVE. LAPORTE AVE. CONIFER ST. E. VINE DR.S. LEMAY AVE.S. LEMAY AVE.W. WILLOX LN.W. WILLOX LN. VICINITY MAP Director Signature PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS ________ DAY OF ________, 20__. LEGAL DESCRIPTION OWNER (SIGNED)Date THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME WITNESS MY HAND AND OFFICIAL SEAL. NOTARY PUBLIC ADDRESS THIS DAY OF MY COMMISSION EXPIRES: AS . (PRINT NAME) 20 .A.D., BY THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER'S CERTIFICATION DWELLING UNIT BREAKDOWN UNIT TYPE:DWELLING UNITS % (DU) SINGLE FAMILY ATTACHED 66 100 TOTAL 66 100.00 BICYCLE PARKING PROVIDED BICYCLE SPACES LOCATED IN GARAGE 198 GROSS / NET GROSS AREA 310,871 SF (7.137 AC) TOTAL DWELLING UNITS 66 GROSS DENSITY 9.25 DU/AC EXISTING ZONING COMMUNITY COMMERCIAL - NORTH COLLEGE DISTRICT (C-C-N) SERVICE COMMERCIAL (S-C) GROSS AREA (SF)% BUILDING COVERAGE 82,205 26.44 DRIVES AND PARKING (EXCLUDES PUBLIC ROW)40,415 13.00 OPEN SPACE AND LANDSCAPE (EXCLUDES PUBLIC ROW)143,113 46.04 HARDSCAPE (EXCLUDES PUBLIC ROW)45,138 14.52 TOTAL GROSS COVERAGE 310,871.00 SF (7.14 AC)100.00 DENSITY AREA COVERAGE LAND USE CHART PROJECT PARKING PROVIDED REQUIRED OFF STREET PARKING 25 132ACCESSIBLE ACCESS PARKING 2* -VAN ACCESSBLE ACCESSIBLE PARKING 1 SINGLE FAMILY ATTACHED GARAGE PARKING 132 TOTAL 160 * INCLUDES ONE (1) VAN ACCESSIBLE PARKING STALL BUILDING BREAKDOWN MODEL TYPE APPLICABLE BUILDING # ON SITE PLAN DWELLING UNITS PER BUILDING 1-BEDROOM UNITS PER BUILDING 2-BEDROOM UNITS PER BUILDING 3-BEDROOM UNITS PER BUILDING TOTAL BEDS PER BUILDING TOTAL NUMBER OF BUILDINGS TOTAL DWELLING UNITS TOTAL BEDS BUILDING HEIGHT # OF STORIES 4-PLEX A 3, 12 4 0 0 4 12 2 8 24 33'-10 1/2"2 4-PLEX B 2 4 0 0 4 12 2 8 24 33'-10 5/8"2 5-PLEX A 4 5 0 0 5 15 1 5 15 36'-8 3/8"2 5-PLEX B 5 5 0 0 5 15 1 5 15 36'-8 3/8"2 5-PLEX C 9 5 0 0 5 15 1 5 15 36'-8 3/8"2 6-PLEX A 1, 10 6 0 0 6 18 1 6 18 36'-8 3/8"2 6-PLEX B 7 6 0 0 6 18 2 12 36 33'-10 1/2"2 7-PLEX B 8 7 0 0 7 21 1 7 21 37'-2"2 7-PLEX A 6, 11 7 0 0 7 21 2 14 42 36'-8 3/8"2 13 70 210 BEING A REPLAT OF BLOCK 1 & TRACT JJJ, OLD TOWN NORTH, AND LOT 2, BLOCK 1, WILL SUBDIVISION, LOCATED IN THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. Sheet Number Sheet Title 1 COVER SHEET 2 OVERALL SITE PLAN 3 SITE PLAN ENLARGEMENT 4 SITE PLAN ENLARGEMENT 5 SITE PLAN ENLARGEMENT 6 SITE PLAN ENLARGEMENT 7 NATURAL HABITAT BUFFER ZONE PLAN 8 OVERALL LANDSCAPE PLAN 9 LANDSCAPE PLAN ENLARGEMENT 10 LANDSCAPE PLAN ENLARGEMENT 11 LANDSCAPE PLAN ENLARGEMENT 12 LANDSCAPE PLAN ENLARGEMENT 13 LANDSCAPE NOTES AND DETAILS 14 LANDSCAPE NOTES AND DETAILS 15 TREE MITIGATION PLAN 16 TREE MITIGATION NOTES 17 BUILDING TYPE 1 ELEVATIONS 18 BUILDING TYPE 1 PERSPECTIVE 19 BUILDING TYPE 2 ELEVATIONS 20 BUILDING TYPE 2 PERSPECTIVE 21 BUILDING TYPE 3 ELEVATIONS 22 BUILDING TYPE 3 PERSPECTIVE 23 BUILDING TYPE 4 ELEVATIONS 24 BUILDING TYPE 4 PERSPECTIVE 25 BUILDING TYPE 5 ELEVATIONS 26 BUILDING TYPE 5 PERSPECTIVE 27 BUILDING TYPE 6 ELEVATIONS 28 BUILDING TYPE 6 PERSPECTIVE 29 BUILDING TYPE 7 ELEVATIONS 30 BUILDING TYPE 7 PERSPECTIVE 31 BUILDING TYPE 8 ELEVATIONS 32 BUILDING TYPE 8 PERSPECTIVE E1.00 ELECTRICAL SITE LIGHTING REGULATIONS E1.01 ELECTRICAL SITE LIGHTING AREAS & ALLOWANCES E1.02 ELECTRICAL SITE LIGHTING PLAN E1.03 ELECTRICAL SITE LIGHTING PHOTOMETRIC PLAN E1.03N ELECTRICAL NORTH SITE LIGHTING PHOTOMETRIC PLAN E1.03S ELECTRICAL SOUTH SITE LIGHTING PHOTOMETRIC PLAN E1.04 ELECTRICAL SITE LIGHTING CUT SHEETS SHEET INDEX *ALL DWELLING UNITS ARE 3-BEDROOMS G G GGGEEEEEEEEEEEEEEEEEEEEEE E E E E E E E E E E UD G G G G G GEE E E E E E UD UD UDE E G G G E E W WWWWWWSSSSS WWWWWWWWWWWWWWWWWWWWWW W SSSSSSSSSSSSSSSSSSSSSSSSSSWW W WWW WWWWWWWWWWS SSSSS SSSS SSS SSSSS S S SSSSSWWWWWWWWWWWWWWS SSSSWSSSWWWWWWW GGE B BBBB BBBBB B BBBBBBBBBBB BB BBBBBB BBBBBBBBBBBB BBBBBBBBBBBBBBBB BBBBB BBBBBBBBBVAULTELEC VAULT CABLE VAULTELEC VAULT ELEC VAULT CABLE TRAFFIC VAULT VAULTELEC HY DVAULTCABLE VAULT ELEC VAULTELEC VAULT CABLE VAULT ELEC VAULT CABLE VAULT ELEC VAULT CABLE VAULT ELEC VAULTELECHYDCONTROL IRR CONTROLIRR CONTROLIRR CONTROL IRR CONTROL IRR CONTROLIRRCONTROLIRR CONTROLIRR CONTROL IRR S S S S S / / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXWWWWWWWWWWWW EEWWW WWWWWW W W WW EEEEEEGGGGGGGGGGGGGGGG SSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS VAULTELEC HY DS CONTROL IRR CONTROLIRR GASEE EEEEFOFOFOFOFOFOGGGWWWWXGSSSSGS S SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHUOHUOHUWGGGGGGGGGGGGGGGG G E E E ELID MHE / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GASSSSSSSSSSSSSSSSSSSSSS 8 6 4 7 BUILDING 1 (6-PLEX) BUILDING 2 (4-PLEX) BUILDING 4 (5-PLEX) BUILDING 5 (5-PLEX) BUILDING 6 (7-PLEX) BUILDING 7 (6-PLEX) BUILDING 8 (7-PLEX) BUILDING 9 (5-PLEX) BUILDING 10 (6-PLEX) BUILDING 11 (7-PLEX) BUILDING 12 (4-PLEX) BUILDING 3 (4-PLEX) B BBBB BBBBB B BBBBBBBBBBB BB BBBBBB BBBBBBBBBBBB BBBBBBBBBBBBBBBB BBBBB BBBBBBBBBJEROME STREETSUNIGA ROAD CAJETAN ST PASC A L S T N. COLLEGE AVEPARCEL NUMBER: 9701300025 ZONING: CS PARCEL NUMBER: 9701316001 ZONING: CS PARCEL NUMBER: 9701316002 ZONING: CS JEROME STREET LAKE CAN A L CAJETAN ST PUBLIC ALLEY BUILDING 1 (6-PLEX) BUILDING 2 (4-PLEX) BUILDING 4 (5-PLEX) BUILDING 5 (5-PLEX) BUILDING 6 (7-PLEX) BUILDING 7 (6-PLEX) BUILDING 8 (7-PLEX) BUILDING 9 (5-PLEX) BUILDING 10 (6-PLEX) BUILDING 11 (7-PLEX) BUILDING 12 (4-PLEX) BUILDING 3 (4-PLEX)JEROME STREETSUNIGA ROAD CAJET A N S T PASCAL STN. COLLEGE AVEJEROME STREET PUBLIC ALLEY CAJETAN ST E. VIE DRIVEN. COLLEGE AVEN. COLLEGE AVESUNIGA ROAD E. VIE DRIVE BLONDEL ST.OSIAND E R S T .BLUE SPRUCE DR.G SS E E W x x UE AE EAE DE G SS E E W WSV WSV # GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY EXISTING TREES TO REMAIN EXISTING FENCE PROPOSED FENCE LEGEND FEMA 500 YR FLOODPLAIN FEMA 100 YR FLOODPLAIN UTILITY EASEMENT ACCESS EASEMENT EMERGENCY ACCESS EASEMENT DRAINAGE EASEMENT EXISTING GAS UTILITY EXISTING STORM DRAIN UTILITY EXISTING SANITARY SEWER UTILITY EXISTINGUNDERGROUND ELECTRIC UTILITY EXISTING WATER LINE UTILITY PARKING COUNT EASEMENT RIGHT OF WAY LINE PROPERTY LINE EXISTING TOPOGRAPHY FIRE SERVICE UTILITY CONCRETE WEIR / SITE WALLS SITE LIGHTING, TYP. SITE SIGNAGE, TYP. FURNISHINGS BY OWNER BBBLANDSCAPE BOULDERS, TYP. CRUSHER FINES 10,238 SF CONCRETE 11,740 SF DRIVES AND PARKING 40,415 SF ENHANCED PAVEMENT 12,095 SF REGIONAL TRAIL 1,689 SF DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: 2 OVERALL SITE PLAN Printed On: 7/26/2023 10:50 AM File Name: 2 OVERALL SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com OVERALL SITE PLAN FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 2 OF 32 NORTH 0 25 50 100 SCALE: 1"=50'-0" SHEET 3 SHEET 4 SHEET 5 SHEET 6 MATCH LINE SEE SHEET 3 MATCH LINE SEE SHEET 4 MATCH LINE SEE SHEET 4 MATCH LINE SEE SHEET 5 MATCH LINE SEE SHEET 5MATCH LINE SEE SHEET 6CONTEXT PLAN PASCAL STREET JEROME STREETCOLLEGE AVE. (US 287)SCALE: 1" = 200'-0" G G G G G GGGGGGGE E EEEEEEEEEEEEEEEEEEEEEE E E E E E E E E E E W WWWWSSSSS WWWWWWWWWWWWW W SSSSSSSSSSSSSSSSWW S SWWWWW EE E BBBBBVAULT ELEC VAULT CABLE VAULT ELEC VAULT ELEC VAULT CABLE TRAFFIC VAULT VAULT ELEC HY DVAULT CABLE VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR S D D S S / / / / / / / // / / / / / / // / / / / / / /XXX/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXX XXXXXXXXXXXXXWWWWWWWWWWWW W EEWWW W W WWWWWWW WWWWWWWWWWWWWWWW W W W W W W W W W W W WWEEEEEEEEEEEEEEEE EEGGGGGGGGGGGG G G G SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSS SS GGGGGGGGGGGG G G G 6 4 R10'-0"R10'-0" R25'-0"BBBBB17'-0" 7'-6" 4'-0" 9'-0" 15'-0" UE 26'-0"14'-0" 9'-0" 17'-0" 35'-10" 32'-0" 9'-0" UE 36'-10" 20'-0" EAE, DE, & UE 30'-1" 22'-0" 33'-1" 34'-8" 9'-0" UE 5'-0" WALK 15'-0" WALK AND UTILITY MAINTENANCE PATH 10'-0" MAJOR WALKWAY SPINE 5'-0" WALK 5'-0" WALK 5'-0" TYP. 5'-0" TYP. 10'-0" WALK 25'-0" SEWER LINE EASEMENT 25'-0" SEWER LINE EASEMENT 9'-0" UE 20'-0" EAE, DE, & UE20'-0" 7'-8"5'-0" 3 14 PRIVACY FENCE SITE WALLS 1 14 PROPERTY BOUNDARY 500-YEAR FLOODPLAIN 100-YEAR FLOODPLAIN PROPERTY BOUNDARY FIRE HYDRANT, TYP. TRANSFORMER, TYP. LOT LINE, TYP. FIRE HYDRANT, TYP. TRANSFORMER, TYP. LANDSCAPE BOULDERS, TYP.SITE FURNISHINGS, TYP. BUILT-IN BENCH SYSTEM, TYP. SITE SIGNAGE, TYP. TRANSFORMER, TYP.JEROME STREETSUNIGA ROAD BUILDING 1 (6-PLEX) BUILDING 2 (4-PLEX) BUILDING 3 (4-PLEX) BUILDING 4 (5-PLEX) BUILDING 5 (5-PLEX)PRIVATE ALLEYCAJETAN ST METAL SCREEN, TYP. G SS E E W x x UE AE EAE DE G SS E E W WSV WSV # GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY EXISTING TREES TO REMAIN EXISTING FENCE PROPOSED FENCE LEGEND FEMA 500 YR FLOODPLAIN FEMA 100 YR FLOODPLAIN UTILITY EASEMENT ACCESS EASEMENT EMERGENCY ACCESS EASEMENT DRAINAGE EASEMENT EXISTING GAS UTILITY EXISTING STORM DRAIN UTILITY EXISTING SANITARY SEWER UTILITY EXISTINGUNDERGROUND ELECTRIC UTILITY EXISTING WATER LINE UTILITY PARKING COUNT EASEMENT RIGHT OF WAY LINE PROPERTY LINE EXISTING TOPOGRAPHY FIRE SERVICE UTILITY CONCRETE WEIR / SITE WALLS SITE LIGHTING, TYP. SITE SIGNAGE, TYP. FURNISHINGS BY OWNER BBBLANDSCAPE BOULDERS, TYP. CRUSHER FINES 10,238 SF CONCRETE 11,740 SF DRIVES AND PARKING 40,415 SF ENHANCED PAVEMENT 12,095 SF REGIONAL TRAIL 1,689 SF DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: 3 SITE PLAN ENLARGEMENT Printed On: 7/26/2023 10:50 AM File Name: 2 OVERALL SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com SITE PLAN ENLARGEMENT FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 3 OF 32 NORTH 0 10 20 40 SCALE: 1"=20'-0" MATCH LINE, SEE SHEET 4 EEEEEEEEEEEEEEEEEEEE E E E E E E E E E EE E E E E E UD UD UDUDUDG G G G G G G G G E E E EWW WWWWWWWWWSSSSSSSSSSSWWWWWSSSSSW SSSWWWGGGGGGB BB B B B B B BBBBBBB BBB BB BBBBBB BBBBBBBBBBBBBBVAULT ELEC VAULT CABLE VAULT ELEC VAULT CABLE HY DS S/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /W W WWWWWWWWWWWWWWWWWWEEGGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGGGGGGGGGGGGGGGGGG7 R339'-5" B BB B B B B B BBBBBBB BBB BB BBBBBB BBBBBBBBBBBBBB5'-0" WALK 34'-10" 33'-0" 5'-0" WALK 17'-0" 9'-0" 20'-0" EAE, DE & UE 20'-0" EAE, DE, & UE 5'-6" 5'-0" TYP.26'-0" 5'-0" WALK 15'-0" WALK 25'-0" SEWER LINE EASEMENT 29'-2" 9'-0" UE 21'-1" 11'-10" 9'-0" UE 30'-0"20'-0" 9'-0" 17'-0" 35'-1" 42'-5" 25'-0" UE, DE & MAINTENANCE EASEMENT 5'-0" WALK 3 14 PRIVACY FENCE 1 14 SITE WALLS PROPERTY BOUNDARY 500-YEAR FLOODPLAIN 100-YEAR FLOODPLAIN PROPERTY BOUNDARY 500-YEAR FLOODPLAIN TRANSFORMER, TYP. CRUSHER FINES PATH EXISTING HYDRANT LOT LINE, TYP. BUILT-IN BENCH SYSTEM, TYP. SITE FURNISHINGS, TYP. LANDSCAPE BOULDERS, TYP. SITE SIGNAGE, TYP.JEROME STREETBUILDING 6 (7-PLEX) BUILDING 7 (6-PLEX) BUILDING 8 (7-PLEX) BUILDING 9 (5-PLEX) DRAINAGE AREA (RAIN GARDEN)PRIVATE ALLEYPRIVATE ALLEYG SS E E W x x UE AE EAE DE G SS E E W WSV WSV # GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY EXISTING TREES TO REMAIN EXISTING FENCE PROPOSED FENCE LEGEND FEMA 500 YR FLOODPLAIN FEMA 100 YR FLOODPLAIN UTILITY EASEMENT ACCESS EASEMENT EMERGENCY ACCESS EASEMENT DRAINAGE EASEMENT EXISTING GAS UTILITY EXISTING STORM DRAIN UTILITY EXISTING SANITARY SEWER UTILITY EXISTINGUNDERGROUND ELECTRIC UTILITY EXISTING WATER LINE UTILITY PARKING COUNT EASEMENT RIGHT OF WAY LINE PROPERTY LINE EXISTING TOPOGRAPHY FIRE SERVICE UTILITY CONCRETE WEIR / SITE WALLS SITE LIGHTING, TYP. SITE SIGNAGE, TYP. FURNISHINGS BY OWNER BBBLANDSCAPE BOULDERS, TYP. CRUSHER FINES 10,238 SF CONCRETE 11,740 SF DRIVES AND PARKING 40,415 SF ENHANCED PAVEMENT 12,095 SF REGIONAL TRAIL 1,689 SF DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: 4 SITE PLAN ENLARGEMENT Printed On: 7/26/2023 10:50 AM File Name: 2 OVERALL SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com SITE PLAN ENLARGEMENT FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 4 OF 32 NORTH 0 10 20 40 SCALE: 1"=20'-0" MATCH LINE, SEE SHEET 5 MATCH LINE, SEE SHEET 3 MATCH LINE, SEE SHEET 6 EEEEEEEEEEEEEEEEEE UD UD UD UD UD UDGG G G G G G G G G G G G G G G GEEEE E E E E E E E E E E E E E E E UD UD E E W WWW WWWWS SSSS SSS SSS S S SSSSWWWWWWWWWW SGGEGB BBBBBBBBBBBBBB BB BBB BBBB BB BBBVAULT CABLE VAULT ELEC VAULT ELECWWWWWW WE EGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGAS WWXXGGGS S S S GGGS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWWGGGGGGGGGGGGG G G GAS R25'-0" R25'-0" B BBBBBBBBBBBBBB BB BBB BBBB BB BBB9'-0" UE 15'-0" CRUSHER FINES TRAIL 10'-0" CRUSHER FINES TRAIL LAKE CANAL COMPANY EASEMENT EXISTING 30'-0" GAS LINE EASEMENT 24'-9" EXISTING 30'-0" UE & DE 30'-0" SEWER LINE EASEMENT 5'-0" TYP. 5'-0" TYP. 23'-3" 20'-0" EAE, DE, & UE 8'-0" 8'-0" 44'-0" R.O.W. 34'-6" 15'-0" 8'-0" WALK 1 14 SITE WALLS TRANSFORMER, TYP. REQUIRED NATURAL HABITAT BUFFER PROPOSED NATURAL HABITAT BUFFER SEE NHBZ PLAN SHEET 7 UTILITY, DRAINAGE, ACCESS & MAINTENANCE EASEMENT PROPERTY BOUNDARY PROPERTY BOUNDARY 100-YEAR FLOODPLAIN 100-YEAR FLOODPLAIN LOT LINE, TYP. LAKE CANAL TOP OF SLOPE AND EDGE OF RIPARIAN FOREST CANOPY TRAIL CONNECTION LANDSCAPE BOULDERS, TYP. SITE SIGNAGE, TYP.JEROME STREET BUILDING 9 (5-PLEX) BUILDING 9 (5-PLEX) BUILDING 11 (7-PLEX) BUILDING 12 (4-PLEX) LAKE CANAL LAKE CA N A L PUBLIC ALLEY SITE LIGHTING, TYP. SITE LIGHTING, TYP. 10' WIDE REGIONAL TRAIL SEGMENT CONCRETE COLOR: YOSEMITE BROWN. RE: CIVIL PLANS FOR SUBGRADE AND DESIGN. CONNECTION TO POWERHOUSE II TRAIL SEGMENT 6" RAISED CURB, TYP. FURNISHINGS BY OWNER METAL SCREEN METAL SCREEN, TYP. METAL SCREEN TREE GRATE TREE GRATE G SS E E W x x UE AE EAE DE G SS E E W WSV WSV # GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY EXISTING TREES TO REMAIN EXISTING FENCE PROPOSED FENCE LEGEND FEMA 500 YR FLOODPLAIN FEMA 100 YR FLOODPLAIN UTILITY EASEMENT ACCESS EASEMENT EMERGENCY ACCESS EASEMENT DRAINAGE EASEMENT EXISTING GAS UTILITY EXISTING STORM DRAIN UTILITY EXISTING SANITARY SEWER UTILITY EXISTINGUNDERGROUND ELECTRIC UTILITY EXISTING WATER LINE UTILITY PARKING COUNT EASEMENT RIGHT OF WAY LINE PROPERTY LINE EXISTING TOPOGRAPHY FIRE SERVICE UTILITY CONCRETE WEIR / SITE WALLS SITE LIGHTING, TYP. SITE SIGNAGE, TYP. FURNISHINGS BY OWNER BBBLANDSCAPE BOULDERS, TYP. CRUSHER FINES 10,238 SF CONCRETE 11,740 SF DRIVES AND PARKING 40,415 SF ENHANCED PAVEMENT 12,095 SF REGIONAL TRAIL 1,689 SF DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: 5 SITE PLAN ENLARGEMENT Printed On: 7/26/2023 10:50 AM File Name: 2 OVERALL SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com SITE PLAN ENLARGEMENT FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 5 OF 32 NORTH 0 10 20 40 SCALE: 1"=20'-0" MATCH LINE, SEE SHEET 4 MATCH LINE, SEE SHEET 6MATCH LINE, SEE SHEET 6MATCH LINE, SEE SHEET 4 8'-0" WALK E E E E E E E E E E EEEE E E E WWWWWWSSSSSSGVAULT ELEC HY DD CONTROL IRR CONTROL IRR EEEEEEEEEEEEFOFOFOFOFOFOFOFOFOFOFOFOFOGGGGGGGWWWWWWWSOHUOHUOHUOHUOHUOHUOHUOHUOHUE E E E E E E E EEELID MHEEEEGGFO / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /OHUOHUSSSSSSSSSSSSSSSSSS8 19'-0" 6'-6" 9'-0" 8'-0" WALK LAKE CANAL COMPANY EASEMENT 15'-0" CRUSHER FINES TRAIL 8'-0" WALK 30'-0" UE 44'-0" R.O.W. PROPERTY BOUNDARY FIRE HYDRANT, TYP. PROPERTY BOUNDARY 100-YEAR FLOODPLAIN REQUIRED NATURAL HABITAT BUFFER PROPOSED NATURAL HABITAT BUFFER SEE NHBZ PLAN SHEET 7 100-YEAR FLOODPLAIN EXISTING PRIVATE ALLEY ACCESS EASEMENT ON ABUTTING PROPERTY TO BE RENOVATED AND CONNECTED TO THE PUBLIC ALLEY IN THIS PLAN, AS PART OF THIS DEVELOPMENT. EXISTING DRIVE TO BE REPAIRED AS NEEDED - FINAL EXTENTS TO BE VERIFIED IN FIELD. LOT LINE, TYP. LAKE CANAL TOP OF SLOPE AND EDGE OF RIPARIAN FOREST CANOPY FUTURE PEDESTRIAN CONNECTION TO COLLEGE TO BE EXTENDED BY OTHERS.TRANSFORMER, TYP. LAKE CANAL BUILDING 10 (6-PLEX)N. COLLEGE AVENUEPUBLIC A L L E Y SITE LIGHTING, TYP. METAL SCREEN, TYP. TREE GRATE G SS E E W x x UE AE EAE DE G SS E E W WSV WSV # GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY EXISTING TREES TO REMAIN EXISTING FENCE PROPOSED FENCE LEGEND FEMA 500 YR FLOODPLAIN FEMA 100 YR FLOODPLAIN UTILITY EASEMENT ACCESS EASEMENT EMERGENCY ACCESS EASEMENT DRAINAGE EASEMENT EXISTING GAS UTILITY EXISTING STORM DRAIN UTILITY EXISTING SANITARY SEWER UTILITY EXISTINGUNDERGROUND ELECTRIC UTILITY EXISTING WATER LINE UTILITY PARKING COUNT EASEMENT RIGHT OF WAY LINE PROPERTY LINE EXISTING TOPOGRAPHY FIRE SERVICE UTILITY CONCRETE WEIR / SITE WALLS SITE LIGHTING, TYP. SITE SIGNAGE, TYP. FURNISHINGS BY OWNER BBBLANDSCAPE BOULDERS, TYP. CRUSHER FINES 10,238 SF CONCRETE 11,740 SF DRIVES AND PARKING 40,415 SF ENHANCED PAVEMENT 12,095 SF REGIONAL TRAIL 1,689 SF DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: 6 SITE PLAN ENLARGEMENT Printed On: 7/26/2023 10:50 AM File Name: 2 OVERALL SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com SITE PLAN ENLARGEMENT FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 6 OF 32 NORTH 0 10 20 40 SCALE: 1"=20'-0"MATCH LINE, SEE SHEET 6MATCH LINE, SEE SHEET 6 EEEEEEEEEE E E E E UD UD G G G G G G G GEE E E E E E E E UD E E W WWW WWWWWWWWWWSSSSS SSSS SSS SSSSS S S SSSSWWWWWWWWWW SSGBBBBBBBBBBBBBBB BBB BB BBB BBB BBBVAULT CABLE VAULT ELEC VAULT ELECHYDD D DW WWW EGGGGGGSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSS GAS GS S SSSSGS S SSSSSSSSSSSSSSSSSOHUOHUOHUOHUFESWWGGGGGGG G E E E EMH / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /F E SF E S FES GASOHUSSSSSSSSSS8 BUILDING 9 (5-PLEX) BUILDING 10 (6-PLEX) BUILDING 11 (7-PLEX) BUILDING 12 (4-PLEX) 100-YEAR FLOODPLAIN PROPOSED NATURAL HABITAT BUFFER REQUIRED NATURAL HABITAT BUFFER REQUIRED NATURAL HABITAT BUFFER PROPERTY BOUNDARY 100-YEAR FLOODPLAIN TOP OF POND BBBBBBBBBBBBBBB BBB BB BBB BBB BBB1 14 SITE WALLS 50' OFFSET FROM CANOPY AS OBSERVED ON SITE AND VIA AERIAL IMAGERY (PER WALK W/ ENVIRONMENTAL PLANNING) 50' OFFSET FROM TOP OF SLOPE FROM LAKE CANAL DITCH WHERE NO SIGNIFICANT VEGETATION EXISTS 2 14 METAL SCREEN 2 14 METAL SCREEN, TYP. 2 14 METAL SCREEN, TYP. 2 14 METAL SCREEN 4 14 TREE GRATE 4 14 TREE GRATE 4 14 TREE GRATE PASC A L S T JEROME STREET LAKE CA N A L PUBLIC ALLEY 50'-0" 50'-0" 50'-0" 50'-0"EEEEEEEEEE E E E E UD UD G G G G G G G GEE E E E E E E E UD E E W WWW WWWWWWWWWWSSSSS SSSS SSS SSSSS S S SSSSWWWWWWWWWW SSGBBBBBBBBBBBBBBB BBB BB BBBBBB BBBVAULT CABLE VAULT ELEC VAULT ELECHYDD D DW WWW EGGGGGGSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSS GAS GS S SSSSGS S SSSSSSSSSSSSSSSSSOHUOHUOHUOHUFESWWGGGGGGG G E E E EMH / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /F E SF E SFE SGASOHUSSSSSSSSSS8 BUILDING 9 (5-PLEX) BUILDING 10 (6-PLEX) BUILDING 11 (7-PLEX) BUILDING 12 (4-PLEX) 100-YEAR FLOODPLAIN PROPOSED NATURAL HABITAT BUFFER REQUIRED NATURAL HABITAT BUFFER REQUIRED NATURAL HABITAT BUFFER PROPERTY BOUNDARY 100-YEAR FLOODPLAIN 112'-11" 30'-3" TOP OF POND BBBBBBBBBBBBBBB BBB BB BBBBBB BBB1 14 SITE WALLS 2 14 METAL SCREEN 2 14 METAL SCREEN, TYP. 2 14 METAL SCREEN, TYP. 2 14 METAL SCREEN 4 14 TREE GRATE 4 14 TREE GRATE 4 14 TREE GRATE PASC A L S T JEROME STREET LAKE CA N A L PUBLIC ALLEY SYMBOL DESCRIPTION QTY REQUIRED NATURAL HABITAT BUFFER ZONE 62,494 SF LEGEND PROVIDED NATURAL HABITAT BUFFER ZONE 80,840 SF ADDITIONAL BUFFER: (S.F BUFFER ABOVE REQUIRED) 18,246 SF TOTAL REQUIRED NHBZ 62,494 SF TOTAL PROVIDED NHBZ 80,840 SF 100% 129% 29% DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Lindsay Oliver Layout: NATURAL HABITAT BUFFER ZONE PLAN Printed On: 7/26/2023 10:50 AM File Name: 2 OVERALL SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. KLARA ROSSOUW 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 BLACK TIMBER LAND COMPANY 417 JEFFERSON STREET Fort Collins, CO 80524 ENGINEER LAND PLANNER/ LANDSCAPE ARCHITECT NORTHERN ENGINEERING ANDY REESE 301 N. HOWES, SUITE 1 Fort Collins, CO 80521 p. 970.221.4158 OWNER 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com NATURAL HABITAT BUFFER ZONE PLAN FDP SUBMITTAL JEROME STREET STATION ---- ---- 04 ---- ---- FDP RD4 SUBMITTAL ---- ---- 07.26.2023 06.07.2023FDP RD3 SUBMITTAL03 04.12.2023FDP RD2 SUBMITTAL02 02.22.2023FDP RD1 SUBMITTAL01 FORT COLLINS, CO SC, KR AG, LO R21-051 7 OF 32 NORTH 0 20 40 80 SCALE: 1"=40'-0" NATURAL AREA BUFFER NOTES 1.STANDARDS FOR PROTECTION DURING CONSTRUCTION - THE DIRECTOR SHALL ESTABLISH A "LIMITS OF DEVELOPMENT" ("LOD") LINE(S) TO ESTABLISH THE BOUNDARY OF THE PROJECT OUTSIDE OF WHICH NO LAND DISTURBANCE ACTIVITIES WILL OCCUR DURING THE CONSTRUCTION OF THE PROJECT. 2.SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER ZONE. 3.CONSTRUCTION SHALL BE ORGANIZED AND TIMED TO MINIMIZE THE DISTURBANCE OF SENSITIVE SPECIES OCCUPYING OR USING ON-SITE AND ADJACENT NATURAL HABITATS OR FEATURES. 4.CONSTRUCTION OF BARRIER FENCING SHALL BE PROVIDED AT THE LIMITS OF THE DEVELOPMENT DURING CONSTRUCTION. NATURAL AREA BUFFER ZONE (NHBZ) SUMMARY THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. NATURAL HABITAT BUFFER ZONE MINIMUM PROPOSED BUFFER DISTANCE.30'-3" MAXIMUM PROPOSED BUFFER DISTANCE.173'-8" AVERAGE BUFFER DISTANCE.88'-4"