Loading...
HomeMy WebLinkAboutMOUNTAIN'S EDGE (FORMERLY 2430 OVERLAND TRAIL - RESIDENTIAL) - PDP - PDP160045 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEW• • FOrt Collins � February 05, 2016 970.221.6750 970.224.6134 - fax fcgov.com Kristin Turner TB Group 444 Mountain Ave. Berthoud, CO 80513 Re: 2430 Overland Trail - Residential � Community Development and Neighbofiood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 •,.. � r� � � "" . � ��� ,- - ' �escription of project: This is a request to construct single-family antl two-family dwellings or single family attachetl dwellings at 2430 Overland Trail (parcel #9721300003) located at the northeast corner of Overland Trail and West Drake Road. The proposed P.D.P. would inclutle 21 two-family or single family attached tlwellings antl 61 single-family homes. The development would include a small private park. Bluegrass Drive woultl be extentled west through to Overland Trail. The site is not currently within City limits and would require Annexation and Initial Zoning into the L-M-N zone per the City's Structure Plan Map. As proposed, the project would be subject to Atlministrative Review (Type One). Please see the following summary of comments regarding the project request referenced above. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications antl additions to these comments may be made at the time of formal review of this project. If you have any questions regarding these comments or the next steps in the review process, you may contact the individual commenter or direct your questions through the Project Planner, Ted Shepard, at 970-221-6343 or tshepard@fcgov.com. Comment Summary: Department: Zoning Contact: Gary Lopez, 970-416-2338, glopez(c�fcgov.com 1. The structure plan indicates that the property would be a Low-Density Mixetl-Use zoning designation. The proposed housing is permitted though please note your tlesignation of tluplex lots below. RESPONSE: Acknowledged. 2. The property requires platting. RESPONSE: Acknowletlged. N 2 •• 3. Duplex lots are 2 dwelling units on a single fee-simple lot. If attached housing is to go to the narrower lots these may be single family attached housing meaning each dwelling is on it's own fee-simple lot. If that is the case please identify these as single family attached dwellings and not duplex lots. RESPONSE: Acknowledged. Department: Water-Wastewater Engineering Contact: Heather McDowell, 970-224-6065, hmcdowell(a�fcqov.com 1. There is an existing 20-inch DIP water main in Overland Trail and a 16-inch DIP main in Drake Road. There is a 6-inch main in Bluegrass Drive that is stubbetl at the property line. This project will be required to connect into that water main in Bluegrass Drive and loop through the site with a secondary connection in either Overland or Drake. RESPONSE: The proposed waterline will connect to the Bluegrass stub and connect to the 20" waterline in Overland Trail. 2. There is an existing 8-inch PVC sanitary sewer main that terminates in a manhole near the southeast corner of this site. There is also an 8-inch sanitary sewer main that terminates in a manhole near the west end of Bluegrass Drive. RESPONSE: The proposed sewer will connect to the Bluegrass manhole. 3. The water conservation stantlartls for lantlscape and irrigation will apply. Information on these requirements can be found at: http:l/www.fcqov.comistandartls RESPONSE: Acknowledged. 4. Development fees and water rights will be due at building permit. RESPONSE: Acknowletlgetl. Department: Traffic Operations Contaci: Martina Wilkinson, 970-221-6887, mwilkinson(a�fcqov.com 1. The anticipated traffic volume from this development meets the threshold for neetling a Traffic Impact Study. Please have your traffic engineer contact me to scope the study. RESPONSE: Acknowledged. 2. Work with the engineering department on necessary frontage improvements to Overland. RESPONSE: Acknowledged. 3. Circulation looks good and the connection to the east will be very nice. RESPONSE: Acknowledged. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlama(�.fcqov.com 1. The site disturbs more than 10,000 sq-ft, therefore Erosion antl Sediment Control 2 • • � •• Materials need to be submitted at the latest by final material submittal. The erosion control requirements are in the Stormwater Design Criteria under the Amendments of Volume 3 Chapter 7 Section 1.3.3. wuuw.fcgov.com/erosion Please submit; Erosion Control Plan, Erosion Control Report, and an Escrow / Security Calculation. If you need clarification concerning the erosion control section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam(a�fcqov.com RESPONSE: Acknowledged. 2. A drainage report and construction plans are required antl they must be prepared by a Professional Engineer registered in the State of Colorado. The drainage report must be prepared in accordance with the Fort Collins Stormwater Criteria Manual. RESPONSE: A drainage report and plan is provided with this submittal. 3. This property is situated in two major tlrainage basins. Canal Importation Basin is located on the northerly half of the site and Spring Creek Basin is located on the southerly half. The design of this site must conform to those master drainage basin requirements as well the Fort Collins Stormwater Criteria Manual. RESPONSE: The drainage plan conforms to the standards for each basin. 4. As a part of the Spring Creek Drainage Basin Master Plan, there is a regional detention basin planned for the west sitle of Overland Trail. Eventual implementation of this basin may reduce flows tlown Dixon Creek, but because the timing of this improvement is unknown, existing-condition flows shoultl be planned for. RESPONSE: Acknowledged. 5. Onsite detention is required for the runoff volume difference between the 100-year developed inflow rate and the 2-year historic release rate. If the tleveloped stormwater tlesign for this site proposes a tlrainage basin transfer, the 2-year historic release rate from each basin will still be upheld. For instance, if you propose to route all stormwater southerly into the Spring Creek Basin, the 2-year historic release rate from that basin will stiil be required and you wouldn't be allowed a larger release from this basin even if you had zero release in the Canal Importation Basin. RESPONSE: A drainage basin transfer is proposed for this site. The release rates will conform to the 2-yr historic for each basin. 6. Stormwater outfall/tie-in options for this site appear to be the following: a. In the Canal Importation Basin, there is a City owned and maintained drainage channel in the Brown's Farm 3rd Subdivision (Brown's Channel). It is located approximately 650' east of the northeast corner of the property. Connection of the channel from its existing terminus to this project site would require an easement from the drive-in movie theatre property. RESPONSE: The tlrainage plan proposes release to both statetl outfall points. b. In the Spring Creek Basin, Dixon Creek runs through the property and outfalls into an existing 18" storm pipe that goes under Drake Road. RESPONSE: Acknowledged. 7. Fifty percent of the site runoff is requiretl to be treated using the standard water quality treatment as described in the Fort Collins Stormwater Manual, Volume 3-Best Management Practices (BMPs). (http:l/www.fcgov.com/utilitieslbusiness/builders-and-developers/development-forms-gui delines-regulationslstormwater-criteria) Extentletl tletention is the usual methotl selected for water quality treatment; however the use of any of the BMPs is encouraged. 3 •• • • RESPONSE: Rain gardens and extended detention are proposetl for this site. Low Impact Development (LID) requirements are mandatory on all new or redeveloping property in the City of Fort Collins. This includes sites required to be brought into compliance with the Land Use Cotle. LID is to provide a higher degree of water quality treatment for 75% of all newly added or modified impervious areas. RESPONSE: 74% of new impervious area is proposetl to be treated through rain gardens, grass buffers, grass channels with infiltration sections. 9. Standard operating procedures (SOPs) for all onsite drainage facilities (including LID systems) will be included as part of the Development Agreement. More information antl links can be found at: http:l/www.fcgov.com/utilitieslwhat-we-do/stormwater/stormwater-q uality/low-impact-dev elopement RESPONSE: Acknowledged. 10. Per Colorado Revised Statute §37-92-602 (8) effective August 5, 2015, criteria regarding detention drain time will apply to this project. As part of the drainage design, the engineer will be requiretl to show compliance with this statute using a standard spreadsheet (available on request) that will need to be included in the drainage report. Upon completion of the project, the engineer will also be required to upload the approved spreadsheet onto the Statewide Compliance Portal. This will apply to any volume based stormwater storage, inclutling extentled detention basins and bio-retention cells. RESPONSE: Acknowletlged. 11. There is a final site inspection required when the project construction is complete and the maintenance is handed over to an HOA or another maintenance organization. RESPONSE: Acknowledged. 12. The 2016 city wide Stormwater development fee (PIF) is $8,2171acre for new impervious area over 350 sq.-ft., and there is a$1,045.00/acre review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found at: http://wuvw.fcgov.comlutilities/business/builders-and-developerslplant-investment-develo pment-fees or contact Jean Pakech at 221-6375 for questions on fees. There is also an erosion control escrow required before the Development Construction permit is issued. The amount of the escrow is determined by the design engineer, and is based on the site tlisturbance area, cost of the measures, or a minimum amount in accordance with the Fort Collins Stormwater Manual. RESPONSE: Acknowledged. Department: Fire Authority Contact: Jim Lynxwiler, 970-416•2869, iynxwiler ,poudre-fire.orq i��Li��:�•�111J�� A fire hydrant is required within 400' on any resitlential home as well as on 800' centers. This condition will be required within the residential subdivision, and an additional hytlrant will be required along Overlantl Trail to correct a hydrant separation deficiency there. Code language provided below. 4 • • �� > IFC 508.1 and Appendix B: RESIDENTIAL REQUIREMENTS: Within the Urban Growth Area, hydrants to provide 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. RESPONSE: Acknowledged. 2. FIRE LANES Fire access is required to within 150' of all exterior portions of each residence and meet current cotle requirements for dead-end roads. Code language provided below. CUL-DE-SACS > FCLUC 3.6.2(B): Cul-de-sacs are permitted only if they do not exceed 660 feet in length and have a turnaround at the end with a minimum outsitle turning radius of 50 feet (100 foot diameter). RESPONSE: Acknowledged. Department: Environmental Planning Contact: Kelly Kimple, 970-416-2401, kkimple(a�fcqov.com 1. An Ecological Characterization Study is required by Section 3.4.1 (D)(1) as the site possesses characteristics that support its inclusion on the natural habitat and features inventory map, including Dixon Creek and native upland plains shrubland. The ECS shoultl adtlresses the tlevelopment plan's tlesign in terms of ineeting General Standartl 3.4.1 (C), as well as items (a) through (I) untler 3.4.1 (D)(1). Please contact me if you woultl like to discuss the scope antl requirements of the ECS further. Also note that the Ecological Characterization Study is tlue a minimum of 10 days prior to the PDP submittal. The ECS should also address 3.4.1 (F)(2) � Connections: If the development site contains existing natural habitats or features that connect to other off-site natural habitats or features (Pine Ridge Natural Area), to the maximum extent feasible the development plan shall preserve such natural connections. If natural habitats or features lie adjacent to (meaning in the region immediately round about) the development site, but such natural habitats or features are not presently connectetl across the development site, then the development plan shall, to the extent reasonably feasible, provide such connection. Such connections shall be designed and constructed to allow for the continuance of existing wildlife movement between natural habitats or features and to enhance the opportunity for the establishment of new connections between areas for the movement of wildlife. RESPONSE: Acknowledged. 2. Please note the buffer zone standard of 50' for naturalized storm drainage channels and isolated patches of native shrubland, as identified in Section 3.4.1(E) of the Land Use Code, as you proceed with your site design process. Furthermore, within the buffer zone, according to Article 3.4.1(E)(1)(g), the City has the ability to determine if the existing landscaping within the buffer zone is incompatible with the purposes of the buffer zone. RESPONSE: Acknowletlged. 3. With respect to lighting, the City of Fort Collins Land Use Code, in Article 3.2.4(D)(6) �� 6 � • requires that "natural areas and natural features shall be protected from light spillage from off site sources." Thus, lighting from the parking areas or other site amenities shall not spill over to the buffer areas. In regard to LED light fixtures, cooler color temperatures are harsher at night and cause more disruption to circadian rhythms for both humans and wildlife. Please consitler a warmer color temperature (3000K or less) for your LED light fixtures. Please also consitler fixtures with dimming capabilities so that light levels can be adjusted as needed. RESPONSE: Acknowledged. 4. With respect to lantlscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(3), requires that you use low-water-use plants and grasses in your landscaping or re-lantlscaping and reduce bluegrass lawns as much as possible. Native landscaping is encouraged as well. RESPONSE: Acknowletlged. 5. The applicant should make note of Article 3.2.1(C) that requires developments to submit a landscape and tree protection plan, and if receiving water service from the City, an irrigation plan, that: "...(4) protects significant trees, natural systems, and habitat, and (5) enhances the pedestrian environment". Note that a significant tree is defined as a tree having DBH (Diameter at Breast Height) of six inches or more. If any of the trees within this site have a DBH of greater than six inches, a review of the trees shall be contlucted with Tim Buchanan, City Forester (970-221-6361 or tbuchanan@fcgov.com) to determine the status of the existing trees and any mitigation requirements that could result from the proposed development. RESPONSE; Acknowledgetl. 6. Our city has an established identity as a forward-thinking community that cares about the quality of life it offers its citizens and has many sustainability programs and goals that may benefit your project. Of particular interest may be the: 1. Green Builtling Program: http:l/www.fcgov.com/enviro/green-building.php, contact Tony Raeker at 970-416-4238 or traeker@fcgov.com 2. Solar Energy: http:l/www.fcgov.com/utilities/resitlential/renewables/solar-contractors-resources, contact Norm Weaver at 970-416-2312 or nweaver@fcgov.com 3. Urban Agriculture: http://www.fcgov.comldevelopmentreviewlurbanagriculture.php 4. Nature in the City Strategic Plan: fcgov.com/planning/natureinthecity/? key=advanceplanning/natureinthecity/, contact Justin Scharton at 970-221-6213 or jscharton@fcgov.com Please consider the City's sustainability goals and ways for your tlevelopment to engage with these efforts. RESPONSE: Acknowledged. Department: Engineering Development Review Contact: Marc Ragasa, 970.221.6603, mraqasa ,�fcqov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are tlue at the time of [� • • � •• building permit. Please contact Matt Baker at 224-6108 if you have any questions. RESPONSE: Acknowledgetl. 2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see: http://www.fcqov.com/enqineerinq/dev-review.php RESPONSE: Acknowietlged. 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyetl, tlamagetl or removed due to construction of this project, shall be replaced or restoretl to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. RESPONSE: Acknowledged. 4. All public sidewalk, tlriveways antl ramps existing or proposed atljacent or within the site neetls to meet ADA standards. If they currently tlo not, they will need to be reconstructed so that they tlo meet current ADA standards as a part of this project. RESPONSE: Acknowledged. 5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Stantlartls (LCUASS). They are available online at: http://www.larimer.orq/enqineerinq/GMARtlStds/UrbanSt.htm RESPONSE: Acknowledged. 6. This project is responsible for dedicating any right-of-way antl easements that are necessary or required by the City for this project. This shall also inclutle the standartl utility easements that are to be provided behind the right-of-way (15 foot along an arterial antl 9 foot along all other street classifications). Drake Road and Overland Trail would both require the 15' easements, while ail the intemal streets will require the 9' easement. RESPONSE: Easements are provided as stated above. 7. Utility plans will be required and a Development Agreement will be recorded once the project is finalized. RESPONSE: Acknowletlgetl. 8. The project will be required to connect to and extend Bluegrass Drive west to Overlantl Trail. RESPONSE: The extension of Bluegrass is providetl with these plans. 9. A street connectionlstub will be needed to the property to the north. RESPONSE: A stub has been provided. 10. A reimbursement for the Drake Road frontage is due for this project. If paid in 2016 the amount due is $220 per liner foot of frontage, due at the time of the first building permit. RESPONSE: Acknowledged. 11. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. RESPONSE: Acknowletlged. 12. In accordance with Section 24-95 of the City Code, the Developer is responsible for 7 •• 8 � • constructing the local portion of public street atljacent to the property prior to the issuance of the first building permit. Improvements to Overland Trail (classified as a 4 lane arterial) will be required at the time of development of the property. Curb, gutter antl sidewalks will need to be constructed in their ultimate location. RESPONSE: Ultimate improvements along Overland Trail are provitled with this proposal. 13. All roadways servicing the duplex units would be private tlrives. RESPONSE: Acknowletlged. 14. Depending on the TIS for the property, additional improvements may be neetled on Overlantl Trail (center turn lane, right turn lane, etc.). The intersection of Drake Road and Overland Trail will also need to be looked at to determine what sort of pedestrian ramp is needed. RESPONSE: A right turn lane and left turn lane into the project is provided with this proposal. 15. A utility coordination meeting on this site is suggested. Utility coordination meetings if requested are typically scheduled after the preliminary submittal of the project, but can be scheduled prior to submittal upon request. Please provitle a site plan with preliminary utility layout for routing with the meeting notice. If you are interested in having a utility coordination meeting, please contact the development review engineer for scheduling. RESPONSE: Acknowledged. 16. Refer to LCUASS Table 7-3 for driveway spacing requirements. It appears the driveways for the homes on Bluegrass off of Overland Trail won't meet the minimum spacing requirements. Also, verify that the access to the site (Bluegrass Drive) meets the spacing requirements. RESPONSE: Spacing for private driveways has been reviewed antl seems to be in compliance with the standards. 17. All fences, barriers, posts or other encroachments within the public right-of-way are only permitted upon approval of an encroachment permit. Applications for encroachment permits shall be matle to Engineering Department for review and approval prior to installation. Encroachment items shall not be shown on the site plan as they may not be approvetl, need to be modified or moved, or if the permit is revoked then the site/ landscape plan is in non-compliance. RESPONSE: No encroachments are plannetl with this proposal. 18. Any rain gardens within the right-of-way cannot be used to treat the development/ site storm runoff. We can look at the use of rain gartlens to treat street flows — the design standards for these are still in development. RESPONSE: No rain gartlens are planned within the right of way. 19. Bike parking requiretl for the project cannot be placetl within the right-of-way and if placed just behind the right-of-way need to be placetl so that when bikes are parked they do not extend into the right-of-way. RESPONSE: Acknowledged. 20. In regards to construction of this site, the public right-of-way shall not be used for staging or storage of materials or equipment associated with the Development, nor shall it be used for parking by any contractors, subcontractors, or other personnel working for or hired by the Developer to construct the Development. The Developer will neetl to find a • • Q � location(s) on private property to accommodate any necessary Staging and/or parking needs associated with the completion of the Development. Information on the location(s) of these areas will be required to be provided to the City as a part of the Development Construction Permit application. RESPONSE: Acknowtedged. Department: Electric Engineering Contact: Todd Vedder, 970-224-6152, tvedder a(�.fcqov.com New tlevelopment and system modification charges may apply. A link to our online electric fee estimator is below. http:l/www.fcgov.comlutilities/business/builders-and-developers/plant-investment-tlevelo pment-feeslelectric-development-fee-esti mator?id=3 RESPONSE: Acknowletlged. 2. Currently there is single phase power on the southwest and centrai eastern part of the development. RESPONSE: Acknowledged. 3. Please contact Light & Power Engineering Department if you have any questions at 970.221.6700. Please reference our Electric Construction, Policies Practices & Procedures to ensure requirements and policies are met. httq:llwww.fcqov.com/utilities/business/builtlers-and-developers RESPONSE: Acknowletlged. 4. Transformer and metering locations will need to be coordinatetl with Light & Power. It is recommended to have the electric meters gained on one side (opposite of gas) for the duplexes. Transformers will need to be within 10' on drive over surface and have an 8' frontal and 3' sidelrear clearance to include landscaping. RESPONSE: Acknowletlged. 5. Secondary services for duplexes will be responsible of developer/electrician to install. Light & Power will provide service to the transformer antl first secondary box (if applicable). RESPONSE: Acknowletlged. 6. Streetlights will need to be placed along public streets. A 40 feet separation on both sides of the light is required between shatletl trees antl streetlights. A 15 feet separation on both sides of the light is required between ornamental trees and streetlights. RESPONSE: Acknowledged. Department: Building Inspection Contact: Sarah Carter, 970-416-2748, scartera(�.fcqov.com 1. Please schedule a pre-submittal meeting for this project. Pre-Submittal meetings assist the designerlbuilder by assuring, early on in the tlesign, that the new commercial or multi-family projects are on track to complying with all of the atlopted City cotles and �7 � 10 • • Standards listed below. The proposed project should be in the early to mid-design stage for this meeting to be effective. Applicants of new commercial or multi-family projects should call 416-2748 to schedule a pre-submittal meeting. Applicants shoultl be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. RESPONSE: Acknowledged. 2. Construction shall comply with the following atlopted codes as amended: 2012 International Building Code (IBC) 2012 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) 2012 International Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International Plumbing Code (IPC) as amended by the State of Colorado 2014 National Electrical Code (NEC) as amendetl by the State of Colorado Fort Collins has amendments to most of the codes listed above. See the fcgov.com/building web page to view them. RESPONSE: Acknowledged. 3. Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC. 2. Multi-family and Condominiums 3 stories max: 2012 IECC residential chapter. 3. Commercial and Multi-family 4 stories and taller: 2012 IECC commercial chapter. RESPONSE: Acknowledged. Planning Services Contact: Ted Shepar�, 970-221-6343, tsheparda(�.fcqov.com 1. The parcef will need to be annexed into the City. Per the City's Structure Plan Map, the zoning will be L-M-N, Low Density Mixed-Use Neighborhood. The Annexation and Zoning procedure requires an Initiating Resolution by City Council, followetl by a recommendation by the Planning and Zoning Board, followed by two readings by City Council. This process takes approximately four months. While, to a degree, the A& Z process may run concurrently with the P.D.P., the A& Z process must be completetl prior to a public hearing on the P.D.P. RESPONSE: This property has been annexed into the City. 2. The Conceptual Review application tloes not make it clear as to exactly what is meant by the term �duplex.� In the L-M-N zone, the proposetl use could either of the following: Dwelling, two-family shall mean a�welling containing two (2) dwelling units, or Dwelling, single-family attached shall mean a single-family dwelling attached to one (1) or more dwellings or buildings, with each dwelling located on its own separate lot. Please clarify. (Please note that the Land Use Code does not contain the terms duplex or townhome.) 10 � • �� � 3. The proposed land uses and density are permitted under L-M-N zoning subject to review by the Administrative Hearing Officer (Type One Review). RESPONSE: Acknowledgetl. 4. Although land uses that are permitted per the Administrative Hearing process are not required to have neighborhood information meeting, staff recommends that a neighborhood meeting be held so that residents of the Brown Farm become aware that Bluegrass Drive will be extended west to intersect with Overland Trail. RESPONSE: Acknowledgetl. 5. Please note that the alleys will be privately ownetl and not dedicatetl to the City of Fort Collins as public right-of-way and should be labeled as such. RESPONSE: Acknowledged. 6. All public streets will be required to feature street trees at no greater than 40-foot intervals to be planted in the parkway. Please contact Light and Power to get a preliminary design of the street light locations as street trees must be kept at least 40-feet from public roatlway lighting. In order to not have an 80-foot gap, ornamental trees may be placed to within 15 feet of a public street light. Note that this requirement inclutles all internal streets as well as Overland Trail and West Drake Road. RESPONSE: Acknowledged. 7. Staff recommends that the common area streetscaping along Overland Trail and West Drake Road be planted in a dense manner, with a series of undulating earthen berms, in order to attenuate the road noise associated with arterial street traffic. RESPONSE: Dense planting including evergreen trees has been provitled along Overiantl Trail. Due to the amount of slope from Overland Trail moving east, undulating berms is not possible north of Dixon Creek. Berming will be provided south of Dixon Creek. 8. Regarding the eight lots in the cul-de-sac south of Dixon Creek, there needs to be a break between the side lots lines of two lots in order to provide a bike/petlestrian connection to the public sidewalk of either Overland Trail or West Drake Road. RESPONSE: Residential south of Dixon Creek has been removed from the current layout. 9. The same comment applies to the northwest area of the project where a connecting walkway from the intemal streets to Overland Trail will be required. RESPONSE: Pedestrian connections have been provided in the NW corner out to Overland Trail. 10. Where the 11 single family lots back onto the Dixon Creek private park, and for the eight cul-de-sac lots, there needs to be uniform treatment of the rear property lines for consistency. RESPONSE: The layout has been revised. We believe this comment is no longer applicable. 11. In the northeast corner, there is a pie-shaped lot that does not e�entl to the limits of the project boundary. This leaves an awkward triangle that appears to be inaccessible except to owners of the subject lot. If this is to be a stormwater detention pond, then access needs to be provided for maintenance. RESPONSE: Additional space has been provitled in the NE corner for detention and it has been labeled accordingly. 12. Is it possible to save any existing trees? Note that any existing tree that is proposed to be removed must be evaluatetl by the City Forester per Section 3.2.1(F) antl mitigated per the value of the tree(s). 11 � 12 • • RESPONSE: A tree inventory and mitigation plan will be providetl for review. It is unlikely that the existing trees can be saved. 13. Please note that the park proposed for the southeast area will be private and should be designated and labeled as such. RESPONSE: Acknowledgetl. 14. Please work with the U.S. Postal Service in advance as to the best locations for the cluster boxes otherwise they may be placed in an area that is unexpected. RESPONSE: We will do that. 15. Where the private alleys terminate at the east and west property lines, there needs to be a solid screen to block headlights. RESPONSE: Acknowledged. Either a solid screen or evergreen landscape screen will be provided. 16. In order to comply with Section 3.5.2, please a typical building envelope layout for both housing types that shows compliance with all minimum setback requirements. The Lot Typicals can also show the street tree locations. RESPONSE: Can you provide additional information on what is required, Should a typical building envelope be providetl for single family housing, townhomes or both? 17. Please be aware of the garage door standards so that garages do not dominate the streetscape. Where single family lots atljoin two streets or private alleys, please consitler side or rear-loading the garages. RESPONSE: Acknowiedged. 18. Where tlrainage conveyances are used to tlirect stormwater, please consitler natural characteristics versus concrete pans. RESPONSE: Acknowledged. 19. The applicant is encouraged to install soft paths to provide access to the private park. RESPONSE: Acknowledged. 20. Three new street names will be neetletl. Be sure that new names are not duplicates (or phonetic sound-alikes) of any existing street within the local 911 calling area which includes Larimer County. Street names shoultl be reflective of the local vernacular in order to create a sense of place and be relatively easy to pronounce and spell. Please refer to www.larimer.orglstreets to check for duplicates. RESPONSE: Acknowledged. 21. Per the documents submitted, and by averaging the two length and two width dimensions, the parcel is size is 20.85 acres. In the L-M-N zone district, Section 4.5(D)(2) requires a mix of housing types such that three housing types are required on parcels containing 20 acres or more. There are ten housing types to choose from but a single housing type must not constitute more than 80% or less than 5% of the total number of dwelling units. RESPONSE: ihe property is 18.5 acres. Two housing types have been provided. 22. The L-M-N zone requires that 90% of the dwellings in the project be within one-third of a mile to either a public park or a neighborhood park. If the park is private, it must be at least one acre and comply with the other stantlards in Section 4.5(D)(6). 23. The requirement to provide a local street stub to the north property line is found in Section 3.6.3(F) -"Utilization and Provision of Sub-Arterial Street Connections to antl From Adjacent Developments and Developable Parcels." RESPONSE: A street stub to the northern property line has been providetl. 12 � • 13 �• 24. Regarding the applicant's question about the use of Private Drives or Street-Like Private Drives, please note that Section 3.6.2(N) states that: Private drives shall not be permitted if by plan or circumstance such drives would, in the judgement of the City Engineer, attract through traffic in such volumes as to render such drives necessary as connections between developments, neighborhoods or other origins and destinations outside of the development plan. Staff interprets this standard in such a way as to require that the necessary street stub to the north be dedicated as a public street. RESPONSE: Per conversations with Ted Sheppard and Engineering, Bluegrass Drive and the North/South Street (connecting to the northern property) will be public streets. All other streets will be private alley's. 25. With Bluegrass Drive being an extension of a public street, and with the street stub to the north required being a public street, it would seem awkward to atlminister and maintain any of the remaining internal streets as private drives. RESPONSE: Per conversations with Ted Sheppard and Engineering, Bluegrass Drive and the NorthlSouth Street (connecting to the northern property) will be public streets. All other streets will be private alley's. 26. Regarding the applicant's question about the feasibility of replacing the single family dwellings with either two family dwellings or single family attached dwellings, please note that greater the divergence between the proposed project antl the existing neighborhootl (with regard to housing types, lot sizes, density, etc.), the greater the need to comply with the compatibility standards fountl in Section 3.5.1, particularly along the east property line. 27. Minimum required parking for two family dwellings and single family attached dwellings is subject to the ratios fountl in Section 3.2.2(K)(1)(a). These ratios are based on the number of bedrooms per unit, not just on per unit basis. RESPONSE: Acknowledgetl. 28. If the project becomes more dominated by two family dwellings and single family attachetl tlwellings, then the applicant is encouraged to provide pockets of guest parking spaces that are equally distributed throughout the project. Pre-Submittal Meetings for Building Permits Pre-Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi-family proiects are on track to complying with all of the adopted City codes and Standards listed below. The proposetl project should be in the early to mid-design stage for this meeting to be effective and is typically scheduletl after the Current Planning conceptual review meeting. Applicants of new commercial or multi-familv proiects are advised to call 970-416-2341 to schedule a pre-submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss cotle issues of occupancy, square footage antl type of construction being proposed. Construction shall complv with the followinq adopted codes as amended: 2012 International Building Code (IBC) 20121nternational Residential Code (IRC) 13 •� 14 • � 2012 /nternationa/ Energy Conservation Code (IECC) 2012 /nternational Mechanical Code (IMC) 2012 International Fuel Gas Code (IFGC) 2012 International P/umbing Code (1PC) as amended by the State of Colorado 2014 National Elecfrical Code (NEC) as amended by the State of Coloratlo Accessibilitv: State Law CRS 9-5 & ICCIANSI A117.1-2009. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Desiqn: Category B. Climate Zone: Zone 5. Enerqv Cotle Use 1. Single Family; Duplex; Townhomes: 2012 IRC Chapter 11 or 2012 IECC Chapter 4 2. Multi-family antl Contlominiums 3 stories max: 2012 IECC Chapter 4 Resitlential Provisions. 3. Commercial and Multi-family 4 stories and taller: 20121ECC Chapter 4 Commercial Provisions. Fort Collins Amendments effective starting 2/17/2014. A copy of these requirements can be obtained at the Building Office or contact the above phone number. RESPONSE: Acknowledged. 14