HomeMy WebLinkAboutBLOOM FILING FOUR - PDP230003 - SUBMITTAL DOCUMENTS - ROUND 3 - ALTERNATIVE COMPLIANCE REQUEST (3)
4025 Automation Way, Suite B2 | Fort Collins, CO 80525 | 970-698-6046 | www.Civilworxeng.com
May 29, 2023
Brad Buckman
Director of Engineering Department
281 North College Avenue
Fort Collins, CO. 80525
RE: Bloom 4th Filing – Larimer County Urban Area Street Standards Variance Request
Dear Mr. Buckman,
Variance Request: Northeast entrance - spacing from arterial intersection.
Issue Identification:
The Bloom 4th filing development includes access to Greenfields Drive, a designated 2-lane
arterial road, in two locations along the east property line. These two access drives were
provided to allow for connectivity through the site based off the City of Fort Collins land use
code guidelines and requirements. Due to a conflict between LCUASS standards for intersection
spacing along arterials and “Street Pattern and Connectivity Standards” (3.6.3(c)) found within
the Fort Collins Land Use Code and the Mulberry & Greenfields PUD Master Plan, a variance for
this access is required. The northern access, which is closest to the intersection of International
Boulevard and Greenfields Drive, deviates slightly from the Larimer County Urban Area Street
Standards (LCUASS) Chapter 9 Section 2.4 and reference Table 7-3 required spacing of 460 lineal
feet (measured from the centerline of the intersection to the centerline of the access). This
variance request is being made to accommodate site sizing and spacing limitations as well as to
allow the site to meet City and PUD standards which require site access every 660 feet.
Proposed Alternate Design:
The northeastern access off Greenfields Drive into the Bloom 4th filing development is proposed
to be located 420 lineal feet south of the intersection of Greenfields Drive and International
Boulevard (see exhibit A attached).
Justification:
Between the requirements set forth by the PUD and the LCUASS Standards, two site accesses
along Greenfields Drive are required for the Bloom 4th Filing site. However, the frontage length
for the site does not allow both intersections to meet the 460-foot spacing requirement. The
southern access was locked in by the access across Greenfields Drive and thus the northern
access would need to be the one to vary from the criteria. Its location was selected to support
traffic flow through the site while meeting the intent of the spacing requirement.
Generally, the requested variance is reasonable due to the anticipated traffic patterns and long-
term loading on Greenfields Drive. Specifically, the access will support inbound and outbound
traffic for the northern half of Bloom Filing 4 and a lesser amount of traffic from Filing 3 to the
east. Due to the proposed grid of streets and connectivity, it is anticipated that fewer than 50
peak hour trips would be observed at this access. The access has exceptional sight distance in
2
both directions and the left-out movement, which would be most affected by access spacing, is
anticipated to be a very low volume movement. Short and long-range analysis of International
Boulevard and Greenfields Drive shows that the northbound approach is unlikely to ever block
this intersection. The forecasted trips to this access as well as the overall traffic studies conclude
that no safety or operational concerns are anticipated with the approval of this variance.
It should also be noted that during meetings with City Staff it was represented that a deviation
from the “Street Pattern and Connectivity Standards” in the PUD was unlikely to be supported
by City Staff and direction was given to pursue this variance from LCUASS standards.
There is no foreseen adverse impact on capital and maintenance costs relating to this variance
request. This variance is not foreseen to be detrimental to the public health, safety, and welfare
nor reduce the design life of the improvement. However It is understood that the City reserves
the right at any time to restrict this access to a right-in/right-out if it becomes an operational or
safety issue or if intersection improvements call for the installation of medians along Greenfields
Drive.
SINCERELY,
Justin C. Beckner, PE
CivilWorx, LLC
423'
B
0 50'100'
SCALE: 1" = 50'
25'GREENFIELDS DRIVE4025 Automation Way
Suite B2
Fort Collins, CO 80525
(970) 698-6046
CivilWorxeng.com
BLOOM 4TH FILING
EXHIBIT A - NORTH ACCESS VARIANCE
FORT COLLINS, CO.5/17/2023
INTERNATIONAL BOULEVARD
CENTERLINE OF NORTHERN BLOOM 4TH FILING ACCESS
CENTERLINE OF INTERNATIONAL BOULEVARD