HomeMy WebLinkAboutOASIS ON OLIVE - PDP - PDP180003 - CORRESPONDENCE - STAFF'S PROJECT COMMENTSCity of M;� Foft Collins April 13, 2018 Oasis Development 231 S Howes St Fort Collins, CO 80521 RE; Oasis on Olive, PDP180003, Round Number 1 Community Development and Neighborhood services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov. com/developmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project.. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Pete Wray, at 970=221-6754 or pwray@fcgov.com. Comment Summary: Department: Engineering Development Review Contact: Katie Andrews, 970-221-6601, kandrews(a-)-fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/09/201.8 04/09/2018: Please clarify what's happening with the two drive approaches— does 2' curb typical existing mean vertical or rollover? The driveways should. be brought up to current LCUASS standards and designed and reconstructed in accordance with detail 706.1 (or 707.1 if the traffic warrants a high -volume drive). Comment Number: 2 Comment Originated: 04/09/2018 04/09/2018` The minimum width for a private drive approach is 24 feet — a variance would be required to allow for the reduced width. Comment Number: 3 Comment Originated: 04./09/2018 04/09./2018: If you do not wish to dedicate the standard utility easements, please provide a variance request in accordance with 1.9.4 of the LCUASS. Comment Number: 4 Comment Originated: 04/09/2018 04/09/2018: The diagonal chase is not a standard design nor is it ideal for this area from the City's perspective. We'd like to work with you on the chase design in this area, there are some locations around the City where the drain directly abuts the drive approach a good example is 619 S College Ave. Comment Number: 5 Comment Originated: 04/09/2018 04/09/2018: It appears that a portion of the fence is being left in the ROW frontage — an encroachment permit would need to be approved in order for this to remain. Comment Number: 6 Comment Originated: 04/09/2018 04/09/2018: 1 did not notice signage for the entrance only/exit only — this is a critical part of the access/drive design, please include a proposal for this with the next submittal. It might be beneficial to include this information in the variance request for the reduced -width driveway as well. Page 1 of 10 Comment Number: 7 Comment Originated: 04/11/2018 04/11/2018: Covered chase drains have been approved in the past in the City. Please include a design for review with your next submittal or provide an exhibit directly to me for a quick review prior to the next submittal. Department: Environmental Planning Contact: Rebecca Everette, 910-416-2626, reveretteOfcgov.com Topic: General Comment Number: 1 Comment Originated: 04/09/2018 04/09/2018: LANDSCAPE PLAN: At the time of Final Plan, please provide detailed species, quantities and planting locations for all shrubs, perennials and grasses, including species for the turf areas and rain gardens. Comment Number: 2 Comment Originated: 04/09/2018 04/09/2018: Thank you for selecting 3000K, full cutoff light fixtures for this project. Comment Number: 3 Comment Originated: 04/09/2018 04/09/2018: Environmental Planning is ready for hearing. Department: Forestry Contact: Molly Roche, , mroche(a)fcaov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 04/10/2018 04/10/2018: There appears to be existing trees on -site.. Please schedule an on -site meeting with City Forestry to obtain tree inventory and mitigation information. All existing trees should be retained and protected to the extent reasonably feasible; Comment Number: 2 Comment Originated: 04/10/2018 04/10/2018: Will the new driveway installation require any grading? Please note that the Ash tree adjacent to the proposed driveway is planned to receive treatment for Emerald Ash Borer by City Forestry.. Comment Number: 3 Comment Originated: 04/10/2018 4/9/2018: Three of the Ash trees shown on landscape plans will not be treated for Emerald Ash Borer by City Forestry. This means that they will be removed within the next couple years. City Forestry would like to discuss a few planting management options with the developer: 1) Developer remove and replace (3) Ash trees within the right-of-way at time of project approval. Replace Ash trees with approved species from the City of Fort Collins Street Tree list. 2) City Forestry remove and replace (3) Ash trees within the right-of-way. Replacement trees to be included in the Ash Replacement Program — paid for and planted by City Forestry. 3) Consider `shadow -planting' between existing Ash trees. This will allow new trees to start establishing before the Ash are removed. I am throwing out these options so that landscape updates coincide with site improvements. It will benefit the development to establish new trees now instead of later. Page 2 of 10 Comment Number: 4 Comment Originated: 04/10/2018 04/10/2018 Please include any proposed landscaping, including trees, on the landscape plan and provide a plant legend to detail quantity, species, size, method of transplant, and species diversity (see LUC 12.1). Comment Number: 6 Comment Originated: 04/10/2018 04/10/2018t There appears to be areas of the site that could benefit from additional trees (east side of parcel). Please consider ornamentals, upright species, or smaller evergreen plants to this area and others where feasible. Department: Historic Preservation Contact: Karen McWilliams, 970-224-6078, kmcwilliams(a-fcaov.com Topic: General Comment Number: 1 Comment Originated: 04/06/2018 04/06/2018: The project is subject to land Use Code Section 3.4.7, Historic and Cultural Resources. This Section is intended to ensure that, to the maximum extent. feasible, new construction is designed to respect the historic character of the site and any historic properties in the surrounding neighborhood. Comment Number: 2 Comment Originated; 04/06/2018 04/06/2018: At its March work session the LPC identified the Area of Adjacency for the historic review of this project. Designated Fort Collins Landmarks within this area are 231 S. Howes Street, the Humphry=Davis House, and 223 South Howes Street, the Dealy-Goode House. Properties with a non -binding determination of individual eligibility are 227 S. Howes Street, 316 West Olive Street, and the Old Town professional Center Building at 315 West Oak/211 W. Canyon Avenue. Comment Number: 3 Comment Originated, 04/06/2018 04/06/2018: The project was discussed at a Conceptual Review by the LPC on March 21, 2018, and is scheduled to return to the LPC on May 16, 2018. Upon completion of its review, the LPC will provide a recommendation on the project to the PBZ. At this meeting, the LPC requested additional information to be provided by the applicant; which staff has made the applicant aware of. Comment Number: 4 Comment Originated: 04/06/2018 04/06/2018: The applicant has indicated that the design will change from that shown on the submittal and presented to the LPC. Historic Preservation staff will provide comments on the design compliance with applicable standards when the revised plans are submitted. Department: Light And Power Contact: Clint Reetz, 970-221-6326, creetz(a-)fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/06/2018 04/06/2018: Currently single phase power is serving the existing property. Any upgrades or changes to the existing electric infrastructure will incur system modification charges. Comment Number: 2 Comment Originated: 04/06/2018 04/06/2018: Developer will be responsible for supplying and installing electric service from the transformer to the multi -family units. Page 3 of 10 Comment Number: 3 Comment Originated: 04/06/2018 04/06/2018: Transformer locations will need to be coordinated with Light & Power. Transformers must be placed within 10 ft of a drivable surface for installation and maintenance purposes. The transformer must also have a front clearance of 10 ft and side/rear clearance of 3 ft minimum. Comment Number: 4 Comment Originated: 04/06/2018 04/06/2018: Meter locations for multi -family attached units will need to be coordinated with Light and Power Engineering. Each unit will need its own meter, it is recommended that the meters be located in one common area. Comment Number: 5 Comment Originated: 04/06/2018 04/06/2018: Please contact Light & Power Engineering if you have any questions call me directly at 970-221-6326. Please reference our policies, development charge processes, and use our fee estimator at http //WwW.fcgov.com/utilities/business/builders-and-developers. Comment Number: 6 Comment Originated: 04/13/2018 04/13/2018: Per a discussion had at PDP where the possibility of an existing transformer on the site may need to be moved, after a site visit it looks like no conflict exists. Department: PFA Contact: Andrew Rosen, , arosen(a-fcgov.com Topic: General Page 4 of 10 Comment Number: 1 Comment Originated: 04/05/2018 04-11-2018 UPDATE The project owner requested clarification on whether an NFPA 13 or 13R sprinkler system would be required. From the provided documentation, this appears to be a multi -family project which will require a full NFPA 13 system. If it can be shown that these are individually owned homes with a lot line between each, then a 13R may be allowed if there is a 2hr vertical and horizontal separation between units. Please contact the Fort Collins building department for further information. 04-10-2018 UPDATE The project team stated that the building was at grade level and that the 29ft 10in height was taken from true ground level. 04/05/2018: AUTOMATED FIRE SPRINKLER SYSTEM This building will require an approved NFPA 13 automated fire sprinkler system. This typically requires a 6" supply line and the plan shall be provided to PFA for approval under separate permit. Please contact PFA at 970-416-2891 with any fire sprinkler questions. Code language follows: GROUP S-2 AUTOMATIC SPRINKLER SYSTEM REQUIREMENTS > IFC 903.2.10: An automatic sprinkler system shall be provided throughout buildings classified as enclosed parking garages (Group &2 occupancy) in accordance with IBC 406.6 OR where located beneath other groups. BALCONIES AND DECKS > IFC 903.3.1.2.1: Sprinkler protection shall be provided for exterior balconies, decks, and ground floor patios of dwelling units where the building_ is of Type V construction. FDC The FDC should be located where it is easily visible and accessed from Olive street. This location will require PFA approval. Code language follows: >IFC 912.2: Fire department connections shall be located on the street side of the building, fully visible and recognizable from the street or nearest point of fire department vehicle access. The location of the FDC shall be approved by PFA. Comment Number: 2 Comment Originated: 04/05/2018 04/05/2018: ADDRESSING/WAYFINDING To assist with prompt emergency response, an overall addressing and wayfinding plan will be required that involves the whole building; the two towers and the single unit. The street address and number should be clearly visible from Olive street. Signage shall be affixed to the elevation facing Olive to indicate the appropriate accessway to each unit. KNOX BOXES If garage doors, security gates or access doors into the towers are required to be opened to gain entrance into the garages or towers, then each one will be designed with an approved Knox Key Switch or other approved access mechanism. The overall access plan should be submitted to PFA for approval. Page 5 of 10 Comment Number: 3 Comment. Originated: 04/05/2018 04/05/2018: PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM TEST > IFC 510 & 110.3.2: New & existing buildings require a fire department, emergency communication system evaluation after the core/shell but prior to final build out. For the purposes of this section, fire walls shall not be used to define separate buildings.. Where adequate radio coverage cannot be established within a building, public=safety radio amplification systems shall be designed and installed in accordance with criteria established by the Poudre Fire Authority. Comment Number: 4 Comment Originated: 04/05/2018 04/05/2018' ACCESS >Access is required to within 150ft of all exterior portions of the building. On the provided site plan dated 3-14-2018, this criteria has been met by measuring from Olive St and Canyon Ave. Comment Number: 5 Comment Originated: 04/05/2018 04/05/2018: HYDRANT A hydrant is required within 300ft of the building. This criteria appears to be met by the hydrant on Olive St. However it is the project team's responsibility to verify volume and pressure. Department: Planning Services Contact: Pete Wray, 970-2.21-6764, pwray(cDfcgov.com. Topic: Building Elevations Comment Number: 9 Comment Originated: 04/10/2018 04/10/2018: Add color to elevations or on separate sheet with material color legend to match call outs.. If these exist by Architect, then use if they match elevations. Are there any roof chimney or FP vents used in units? Comment Number: 10 Comment Originated: 04/10/2018 04/10/2018; Refer to Historic Preservation staff and LPC comments for building design compatibility requirements. Topic: General Comment Number: 7 Comment Originated: 04/10/2018 04/10/2018: Utility Plans. Label all sheet title blocks and on plans correct address of 310 W Olive, not 312 typ. all sheets. Comment Number: 8 Comment Originated: 04/10/2018 04/10/2018: Utility Plan shows new site wall Sheet 3 in front of garage on Olive Street. Need to show on all other plans including detail of this design. Comment Number: 11 Comment Originated: 04/10/2018 04/10/2018: PDP R2 Review. If staff determines this PDP is ready for P & Z Board hearing in May during the staff review meeting on April 11, 1 will need a revised plan set (same as LPC plan set) submitted by May 2 for packet. Prior this this date, please confirm with Katie Andrews Engineering comments are addressed in revised plan set, including any variances as identified in her comments. If they are not addressed and she determines this project is not ready for hearing, it will be deferred to June meeting with the Board. Page 6 of 10 Topic: Landscape Plans Comment Number, 4 Comment Originated: 04/10/2018 04/10/2018: See site plan redline notes for ex. tree on Olive, and ex. metal fence. Comment Number: 6 Comment Originated: 04/10/2018 04/10/2018: Please add foundation planting on garage wall facing Olive Street, see redline. Add some additional taller planting in foundation strip at base of stair tower to soften tall wall. Comment Number: 6 Comment. Originated: 04/10/2018 04/10/2018: Sheet LS-2. Add planting legend, and details of all landscape materials such as cobble mulch, LID rain garden planters, fencing, other? Topic: Site Plan Comment Number: 1 Comment Originated: 04/10/2018 04/10/2018: Fencing: Label existing metal fence column if maintaining this with removal of remainder of fence. Add labels for new 6' cedar fence in all locations. New site wall shown on Utility Plan Sheet 3 in front of garage on Olive St. needs to be shown on all plans. Need detail of this design. Comment Number: 2 Comment Originated: 04/10/2018 04/10/2018: Site Plan Legend: Add parking calculation for existing standard (Required spaces), then compare to TOD Overlay calculations. Comment Number: 3 Comment Originated: 04/10/2018 04/10/2018- Exist. Ash tree on Olive label either retaining or removal. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, jschlam(o�fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 03/30/2018 03/30/2018: The site disturbs more than 10,000 sq. ft. and therefore Erosion and Sediment Control Materials need to be submitted. (the lot is --9700 SF but the off lot. work with curb gutters and utilities installations put this project about-11,000 SF) The erosion control requirements can be located in the Stormwater Design Criteria under -the Amendments of Volume 3 Chapter 7 Section 1.3.3. a copy of the erosion control requirements can be found at www.fcgov.com/eroison. The Erosion Control Materials will need to be submitted at time of the first round of FDP. If you need clarification concerning the Erosion Control Material Requirements or Comments presented above please contact myself. Jesse Schlam (970) 224-6015 jschlam@fcgov.com Contact! Mark Taylor, 970-416-2494, mtaylor(cD_fcgov.com Topic: Drainage Report Comment Number: 2 Comment Originated: 04/09/2018 04/09/2018: Please describe portions of the site as being in the City's Old Town Basin and indicate the presence of the City -regulated 100-year floodplain, as well as the FEMA Map Panel number and the date of the City's Master Plan. Also, include a copy of the FEMA Map Panel with the site location noted in red. Page 7 of 10 Comment Number: 3 Comment Originated: 04/09/2018 04/09/2018: The second half of the paragraph CITY FLOODPLAIN/FLOODWAY should be changed. The building it not in the floodplain, so there is no need for an RFPE, a minimum elevation of the building, for venting to be provided, or any sort of hold on the certificate of occupancy. Any grading in the floodway, utility cuts, or driveway changes will need a floodplain use permit and a no -rise certification. Topic: Floodplain Comment Number: 5 Comment Originated: 04/09/2018 04/09/2.018: On Sheets 4 and 5 of the Utility Plans, please add a. note that any utility work in the floodway must be preceded by a floodplain use permit and no -rise certification. Comment Number: 6 Comment Originated: 04/09/2018 04/09/2018: On Sheets 4 and 5 of the. Utility Plans, please add a note stating that storage of equipment and materials is not allowed within the floodway. Comment Number: 7 Comment Originated: 04/09/2018 04/09/2018: On Sheet 5 of the Utility Plans, an RFPE is listed with XS #3164. Since the building is not in the floodplain, this elevation is not relevant and does not need to be included. Topic: Site Plan Comment Number: 4 Comment Originated: 04/09/2018 04/09/2018: Please show and label the current effective City -regulated 100-year floodplain and floodway boundaries. Contact: Wes Lamarque, 970-416-2418, wlamaraue(a)-fcgov.com Topic: General Comment Number: 8 04/10/2018: The LID concept meets City Criteria. Department: Technical Services Contact: Jeff County, 970-221-6588, icountv(aD_fcaov.com Topic: Building Elevations Comment Originated: 04/10/2018 Comment Number: 2 Comment Originated: 04/06/2018 04/06/2018: There are line over text issues. See redlines. Comment Number: 3 Comment Originated: 041/06/2018 04/06/2018: There is text that needs to be masked. Mask all text in hatched areas. See redlines. Topic: Construction Drawings Comment Number: 4 Comment Originated: 04/06/2018 04/06/2018: Please add the Lot, Block, and Subdivision of this project to the sub -title on sheet 1. Comment Number: 5 Comment Originated: 04/06/2018 04/06/2018: Please revise the Benchmark Statement as marked. See redlines. Comment Number: 6 Comment Originated: 04/06/2018 04/061.2018: Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See redlines. Page 8 of 10 Comment Number: 7 Comment Originated: 04/06/2018 04/06/2018: There are line over text issues. See redlines. Topic; Landscape Plans Comment Number: 1 Comment Originated: 04/06/2018 04/06/2018: There are line over text issues. See redlines. Department: Traffic Operation Contact: Tim Tuttle, , TTUTTLE(&fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/09/2018 04/09/2018: The distance from the new diagonal parking on Canyon to the driveway should be 5 ft. Comment Number, 2 Comment Originated: 04/09/2018 04/09/2018: Please show the location of any new or relocated signs. Comment Number: 3 Comment. Originated: 04/09/2018 04/09/2018: Signing and striping redlines will be provided at the Staff Review meeting. Department: Water Conservation Contact: Eric Olson, 970-221-6704, eolson(&fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/10/2018 04/10/2018: A landscape plan shall contain accurate and identifiable hydrozones, including a water budget chart that shows the total annual water use, which shall not exceed fifteen (15) gallons per square foot over the site. If you have questions contact Eric Olson at eolson@fcgov.com or 970-221-6704. . Comment Number: 2 Comment Originated: 04/10/2018 04/10/2018: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson., at 221-6704 or eolson@fcgov,com Department: Water -Wastewater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue(a)-fcgov.com Topic: General Comment Number: 1 Comment Originated: 04/10/2018 04/10/2018: The water service does not meet City distance requirements form other improvements and will need to be relocated. Comment Number: 2 Comment Originated: 04/10/2018 04/10/2018: Please draw the water meter pit per scale. A 2-inch meter pit requires a 4-foot manhole. Department: Zoning Contact: Missy Nelson, , mnelson(aD-fcgov.com Topic: General Page 9 of 10 Comment Number: 1 Comment Originated: 04/09/2018 04/09/2018: The correct address is 310 W. Olive St (I confirmed this with our GIS department). Please correct on all documents for next rounds submittal. GIS contact: Email: gis@fcgov.com Phone: 970.416.2483 Comment Number: 2 Comment Originated: 04/09/2018 04/09/2018: What is your exiting plan for garage bay/parking space number 8? Is there an interior pedestrian access? Also, for the car to then exit, will they have to open the other garage to go through and exit? I have a feeling they won't do so and will just exit through the entrance. Pedestrian access to and from parking garage? Comment Number: 3 Comment Originated: 04/09/2018 04/09/2018: All rooftop mechanical equipment shall be screened from public view from both above and below by integrating it into building and roof design to the maximum extent feasible. Where will the mechanical equipment be located? In addition, conduit, meters, vents and other equipment attached to the building or protruding from the roof shall be painted to match surrounding building surfaces. Please make sure there's a note on the site plan. Comment Number: 4 Comment Originated: 04/09/2018 04/09/2018: Please add drive aisle dimensions. Comment Number: 6 Comment Originated: 04/09/2018 04/09/2018: A full landscape plan will need to be submitted at Final. Comment Number: 6 Comment Originated: 04/11/2018 04/1112018: LUC 3.2.2The 1 handicap parking space shall be designated as van -accessible and must be a minimum of 8 feet wide and adjoin a minimum 8 foot wide access aisle. Page 10 of 10