HomeMy WebLinkAboutSIT AND STAY DOG BAR - FDP230005 - SUBMITTAL DOCUMENTS - ROUND 2 - SUPPORTING DOCUMENTATION WORD\DATA\FORMS\C-1.DOC REV.February 28, 2023 COMMERCIAL SERVICE INFORMATION FORM (C-1) City of Ft. Collins Electric Utility  700 Wood St.  P.O. Box 580  Ft. Collins, CO 80522 (970)221-6700 or fax (970)221-6619 Service voltages available are (not all voltages are available at all locations):  120/240 V. 1 phase, 3 wire  120/208 V. 3 phase, 4 wire  120/208 V. 1 phase, 3 wire (network)  277/480 V. 3 phase, 4 wire  Primary 13,200 V. Grd Y /7620  120/240 V. 3 phase, 4 wire (special utility permission required) Any meter exceeding 200 Amps will require CT’s. For CT’d meters, Light and Power will provide the meter socket and CT’s to the electrical contractor. CT’s cannot be placed in the transformer, but may be located in a building mounted cabinet (provided by owner) or in the owner’s switchgear. In no case, can meters be mounted on the transformer. All commercial services must include the following to be provided and installed by owner: • If CT’d metering, one - 1” conduit from the CT location to the electric meter. • For all 3 phase and/or over 200 amp meters, the owner is encouraged to install a 1” conduit from the meter socket to the phone room for meter reading purposes. As an alternative, the Utility may install a cellular or other communication system at the meter and add a monthly fee (appx. $40.00) to the electric bill. +Please complete the following completely and legibly: Date Submitted: 02.28.23 Voltage Requested: 120/208  1 phase OR  3 phase Building Main (not fuse) Size: 1200 Amps Number of Conduits: 4 Size of Conduits: 4” Number of Cables: 16 Size of Cables:#500 MCM Aluminum Electric Heat:  Yes ____6.0_____kW  No Business Name: Site Address: Owners Name: Mail Address: City: State & Zip: Phone: General Contractor: _________________________________ Individual: _________________________________________ Mail Address: ______________________________________ City: ______________________________________________ State & Zip: ________________________________________ Phone: ____________________________________________ Electrical Contractor: ________________________________ Mail Address: ______________________________________ City: ______________________________________________ State & Zip: ________________________________________ Phone: ____________________________________________ Firm: ______________________________________________ Number of CT’d meters: 1 at 1200 Amps each Number of Self-Contained meters: at Amps each Largest Motor: 1/2 H.P. 1 Phase 3/4 H.P. 3 Phase Will any generating system (including photo-voltaics) be installed?  Yes (contact utility for requirements)  No If Yes, this will be for:  emergency service  parallel generation Will a fire pump be installed? □ Yes □ No Form Completed by: Name: Randy J. Bremmer Company: APS, Inc. Mail Address: 7726 Park Ridge Circle City: Fort Collins State & Zip: Colorado 80528 Phone: (970) 206-0269 For Office Use Only Transformer Size: ____________________kVA Fault Current at Transformer: _______________________Amps 1st 50% - Control # _______________ Paid Date: _____________ 2nd 50% - Control # ______________ Paid Date: _____________ 100% Const./Energize - Cont. # _________ Paid: _____________ A.T.E. Date: _____________________ Engineering Approval by: ______________ Date: _____________ Metering Approval by: ________________ Date: _____________