Loading...
HomeMy WebLinkAboutSIT AND STAY DOG BAR - FDP230005 - SUBMITTAL DOCUMENTS - ROUND 2 - SITE PLANDRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Alex Garvert Layout: Cover Printed On: 6/21/2023 11:25 AM File Name: Cover Page.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. Katy Thompson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Patrik Duncan e. prduncan67@gmail.com p. 970.413.9559 ENGINEER LANDSCAPE ARCHITECT OLSSON ENGINEERING David Pendleton 1880 Fall River Drive, Suite 200 Loveland, CO 80538 p. 970.461.7733 VFLA ARCHITECTURE + INTERIORS Chris Aronson 419 Canyon Avenue, Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER ARCHITECT 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com COVER FDP SUBMITTAL SIT AND STAY DOG BAR 05 04 FDP ROUND 2 PERMIT SET 06/21/2023 02/28/2023 02/15/2023FDP ROUND 103 08/24/2022PDP ROUND 202 09/22/2021PDP ROUND 101 FORT COLLINS, CO RL AG R21-026 L1 OF 5 NORTH SIT AND STAY DOG BAR FINAL DEVELOPMENT PLAN VICINITY MAPLAND USE CHART EXISTING ZONING SERVICE COMMERCIAL (CS) GROSS AREA (SF)% BUILDING COVERAGE 12,814 11.57 DRIVES AND PARKING 30,241 27.31 OPEN SPACE AND LANDSCAPE 53,660 48.46 HARDSCAPE 14,007 12.65 TOTAL GROSS COVERAGE 110,722.00 SF (2.54 AC)100.00 AREA COVERAGE NET AREA (SF)% BUILDING COVERAGE 12,814 11.57 DRIVES AND PARKING 30,241 27.31 OPEN SPACE AND LANDSCAPE 53,660 48.46 HARDSCAPE (WALKS & PLAZAS)14,007 12.65 TOTAL NET COVERAGE 110,722.00 SF (2.54 AC)100.00 LOT 3, COUNTRY CLUB CORNERS SIXTH FILING, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. LEGAL DESCRIPTION* REQUIRED SPACES FOR RESTAURANT USE ARE CALCULATED AS FOLLOWED: RESTAURANT FLOOR AREA = 3,644 SF RESTAURANT PARKING STANDARD: 5 / 1,000 SF 3,644 SF / 1,000 SF = 3.64 X 5 = 18.22 **NO PARKING REQUIREMENT LISTED FOR DOG KENNEL USE DOG KENNEL FLOOR AREA = 9,171 SF 43 SPACES / 9,171 SF = .0047 X 1,000 SF = 4.7 SPACES PROVIDED / 1,000 SF PARKING BASED ON PROJECTED DEMAND *** INCLUDES 3 (THREE) VAN ACCESSIBLE PARKING STALL PROJECT PARKING PROVIDED REQUIRED* OFF-STREET PARKING 58 19ACCESSIBLE PARKING***4 -VAN ACCESSIBLE 3 TOTAL 62 19 BUILDING HEIGHT MAXIMUM HEIGHT STORIES PRIMARY STRUCTURE 26'-7"1 SATELLITE BAR 13'-6"1 STAGE STRUCTURE 17'-0"1 SITE PLAN NOTES 1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3.REFER TO THE UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 8.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11.THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL AND LANDSCAPE MAINTENANCE ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 12.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 13.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND Revised November 12, 2015 3 LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 14.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. OWNER (SIGNED)Date THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME WITNESS MY HAND AND OFFICIAL SEAL. NOTARY PUBLIC ADDRESS THIS DAY OF MY COMMISSION EXPIRES: AS . (PRINT NAME) 20 .A.D., BY THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER'S CERTIFICATE Director Signature PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS ________ DAY OF ________, 20__. SCALE: NTS BICYCLE PARKING PROVIDED REQUIRED BICYCLE SPACES RESTAURANT *4 4 DOG KENNEL **6 0 TOTAL 10 4 * REQUIRED BICYCLE PARKING SPACES ARE CALCULATED AS FOLLOWED: RESTAURANT FLOOR AREA = 3,644 SF RESTAURANT PARKING STANDARD: 1 / 1,000 SF 3,644 SF / 1,000 SF = 3.644 X 1 = 3.644 **NO BICYCLE PARKING REQUIREMENT LISTED FOR DOG KENNEL USE DOG KENNEL FLOOR AREA = 9,171 SF 6 SPACES / 9,171 SF X 2,000 SF = 1.3 SPACES PROVIDED / 2,000 SF PARKING BASED ON PROJECTED DEMAND FLOOR AREA RATIO BUILDING AREA (SF)12,814 LOT AREA (SF)110,722 FLOOR AREA RATIO 0.12 Sheet Number Sheet Title L1 Cover L2 Site Plan L3 Site Plan Details L4 Landscape & Tree Mitigation L5 Landscape Notes & Details SHEET INDEX G SXXXXXXXXX XX XXXXXXXXXXXXXX 7 L3 X X XXX7 L3 15 13 10 4 6 14 XXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X XXXXXXXXX7 L3 EXISTING PRIVATE DRIVE (30') UNLEASHED ZONE EXISTING BUILDING DOG KENNEL RESTAURANT & BAR UNLEASHED ZONE PRIVATE PARTY UNLEASHED ZONE 8" CURB BORDER 10'-0" DRAINAGE ESMT 10'-0" DRAINAGE ESMT 7' CHAIN LINK FENCE GATE WITH PANIC HARDWARE EXISTING PRIVATE DRIVE (30') EXISTING PRIVATE DRIVE (30') 10'-0" SIDEWALK 30'-0" 9'-0"9'-0" 5'-0" 9'-0" 29'-10" 7'-0" SIDEWALK 9'-0" 18'-0" 9'-0"9'-0" 5'-0" 40'-5" 191'-1" 105'-9" 6'-0" CONCRETE WALK 5'-0" 9'-0" 6'-0" 30'-0" ACCESS, UTILITY, AND DRAINAGE ESMT. 5'-0" 7' CHAIN LINK FENCE GATE WITH PANIC HARDWARE 6'-0" CONCRETE WALK RAISED STAGE (FUTURE PHASE) TRASH ENCLOSURE LOCATION SATELLITE BAR AND RESTROOMS (FUTURE PHASE) BIKE PARKING (10 SPACES) GREASE INTERCEPTOR WATER METER PROPERTY BOUNDARY RAISED PATIO OUTDOOR KENNELS RAMP DOG VESTIBULE STAGE STRUCTURE (FUTURE PHASE) PROPERTY BOUNDARY PROPOSED BUILDING 12,814 SQUARE FEET WALK RAMP LEASHED AREA HANDICAP SIGN, TYP. 42" RAILING RE: ARCH 4' SPLIT RAIL FENCE LARGE DOG OUTDOOR PLAY AREA SMALL DOG OUTDOOR PLAY AREA LANDING MOVEABLE SEATING AND TABLES (FUTURE PHASE) UNLEASHED ZONE ACCESS STAIR MAINTENANCE ACCESS GATE DOG TIMEOUT VESTIBULE PRIVATE PARTY PATIO TRANSFORMER PRIMARY ENTRANCE EMPLOYEE ENTRANCE STAFF PATIO MAINTENANCE GATE ROOF LINE (FUTURE PHASE) IRRIGATION METER BENCHES (2) KENNELS FIRE ACCESS SIGN FIRE ACCESS SIGN FIRE ACCESS SIGN FIRE ACCESS SIGN 9'-0" 17'-0" 7' CHAIN LINK FENCE GATE WITH PANIC HARDWARE TRASH AND RECYCLE RECPTACLE FDC CONNETION POINT 17'-0"17'-0" 30'-0" ACCESS, UTILITY, AND DRAINAGE ESMT. 10'-0" UTILITY ESMT 9'-0" STORM TECH CHAMBERS RE: CIVIL 67'-6" DRAINAGE ESMT 95'-0"DRAINAGEESMT60'-0" DRAINAGE ESMT 29'-0" DRAINAGE ESMT LAWN HYDRANT LAWN HYDRANT TRENCH DRAIN X X UD W G SS P-UG X SD = PROPOSED 7' VINYL COATED CHAINLINK FENCE = PROPOSED 7' VINYL FENCE = PROPOSED RAILING = PROPOSED 5' SPLIT RAIL FENCE = PROPERTY BOUNDARY = STORMWATER UTILITY = WATER UTILITY = GAS UTILITY = SANITARY SEWER UTILITY = ELECTRIC UTILITY = UNDER DRAIN = SETBACK = RIGHT OF WAY = PROPOSED GRADING SS G E W FO P-UG G = EXISTING UNDERGROUND POWER UTILITY = EXISTING LIGHT POLE = EXISTING GAS UTILITY = PROPOSED STORMWATER INLET = PROPOSED SIGN = PROPOSED MANHOLE = EXISTING SANITARY SEWER = EXISTING GAS LINE = EXISTING ELECTRIC LINE = EXISTING WATER LINE = EXISTING FIBER OPTIC LINE = EXISTING STORMWATER UTILITY = EXISTING TOPOGRAPHY CONCRETE DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Alex Garvert Layout: 1 Site Plan Printed On: 6/21/2023 11:25 AM File Name: 1 Site Plan.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Katy Thompson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Patrik Duncan e. prduncan67@gmail.com p. 970.413.9559 LANDSCAPE ARCHITECT VFLA ARCHITECTURE + INTERIORS Chris Aronson 419 Canyon Avenue, Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER ARCHITECT ENGINEER OLSSON ENGINEERING David Pendleton 1880 Fall River Drive, Suite 200 Loveland, CO 80538 p. 970.461.7733 SITE PLAN FDP SUBMITTAL SIT AND STAY DOG BAR 05 04 FDP ROUND 2 PERMIT SET 06/21/2023 02/28/2023 02/15/2023FDP ROUND 103 08/24/2022PDP ROUND 202 09/22/2021PDP ROUND 101 FORT COLLINS, CO RL AG R21-026 L2 OF 5 NORTH 0 10 20 40 SCALE: 1"=20'-0" LEGEND NOTE: MOVEABLE SITE FURNISHINGS ARE CONCEPTUAL AND ARE SUBJECT TO CHANGE OR BE REMOVED DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Alex Garvert Layout: Site Plan Details Printed On: 6/21/2023 11:25 AM File Name: 1 Site Plan.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Katy Thompson 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 Patrik Duncan e. prduncan67@gmail.com p. 970.413.9559 LANDSCAPE ARCHITECT VFLA ARCHITECTURE + INTERIORS Chris Aronson 419 Canyon Avenue, Suite 200 Fort Collins, CO 80521 p. 970.224.1191 OWNER ARCHITECT ENGINEER OLSSON ENGINEERING David Pendleton 1880 Fall River Drive, Suite 200 Loveland, CO 80538 p. 970.461.7733 SITE PLAN DETAILS FDP SUBMITTAL SIT AND STAY DOG BAR 05 04 FDP ROUND 2 PERMIT SET 06/21/2023 02/28/2023 02/15/2023FDP ROUND 103 08/24/2022PDP ROUND 202 09/22/2021PDP ROUND 101 FORT COLLINS, CO RL AG R21-026 L3 OF 5 7' VINYL FENCE AND GATE NTS1 OP-SI1-04 541 2 [1384mm] 32 [813mm] 2 [51mm] 28 [711mm] Ø12 [Ø305mm] Ø5 [Ø127mm] Ø235 8 [Ø600mm] Ø235 8 [Ø600mm] TRASH AND RECYCLE RECEPTACLE NTS SITE PRODUCT: TRASH AND RECYCLE RECEPTACLE: KEYSTONE RIDGE HARMONY DUAL RECYCLE/LITTER RECEPTACLE, HIII-32DRT, 32 GAL, GLOSS BLACK, SURFACE MOUNT. PHONE: 724-284-1213 4 OP-PMF-32 71 73 1/2 73 33 21/3223 13/16 BENCH NTS SITE PRODUCT: BENCH: KEYSTONE RIDGE BESSEMER BENCH WITH BACK, 72" BE26, BLACK COAT, SURFACE MOUNT. PHONE: 724-284-1213 5 OP-PMF-33 7' VINYL COATED CHAIN LINK NOT TO SCALE TOP RAIL NOTES: 1)CHAIN LINK SHALL BE VINYL COATED BLACK OR OTHER DARK COLOR 2)SEE PLANS FOR GATE LOCATIONS POST 7'-0" BURY POST IN CONCRETE FOOTING OP-SI1-11 6 5 STALL LOOP BIKE RACK NOT TO SCALE 2" SCH. 40 STEEL PIPE NOTES: 1.INSTALL BIKE RACKS ACCORDING TO MANUFACTURER'S RECOMMENDATIONS 2.OWNER OR OWNER'S REP TO SELECT COLOR AND FINISH 3.SEE SITE AND LANDSCAPE PLANS FOR BIKE RACK LOCATIONS CONCRETE PAD SURFACE MOUNT ELEVATION VIEW PLAN VIEW 3 OP-SI1-12 7' CHAIN LINK FENCE GATE WITH PANIC HARDWARE 1/2" = 1'-0" POST TOP OF RAIL 7'-0" PANIC HARWARE SHALL BE LOCATED ON DOG PARK SIDE OF FENCE GATE. (SEE NOTES BELOW) NOTES: PANIC HARDWARE -MANUFACTURER: GREAT FENCE -MODEL: PANIC BAR KIT -COLOR: BLACK 1'-6" PLATE 4'-0" GATE 3'-0" 7 OP-SI1-14 8' - 0" 1'-0" 30" MIN. 3" MIN 5' SPLIT RAIL FENCE 3/8" = 1'-0" 1 2 3 7 4" MINIMUM CLEARNACE 6 22 3 5 NOTE: ALL WOOD TO BE WESTERN RED CEDAR. APPLY TWO COATS OF APPROVED EXTERIOR SEMI-TRANSPARENT OIL STAIN TO WOOD - DIAMOND VOGEL AG-SERIES GRAIN STAIN OR APPROVED EQUAL. 30" MIN. 8 4X4 POST1 2X4 HORIZONTAL SLAT2 4" X 4" WIRE MESH3 4 X 4 GATE POST. SEE PLAN FOR LAYOUT5 BOERBOL STANDARD WRAP HINGE (BLACK), TYP. INSTALLED PER MANUFACTURERS RECOMMENDATIONS6 CONCRETE FOOTING FOR EACH POST, TYP.7 BOERBOL HEAVY-DUTY GATE LATCH (BLACK), INSTALLED PER MANUFACTURERS RECOMMENDATION. LATCH FOR GATE SHOULD FACE THE INSIDE OF THE HOLDING AREA 8 3" 3" 3" 5'-0" 2 OP-SI1-31