Loading...
HomeMy WebLinkAboutCROWNE AT SUNIGA - PDP230007 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (3)12'' W 12'' W 12'' W 12'' W 12'' W 12'' W 60'' W 60'' W 60'' W 60'' W 60'' W T42'' W 42'' W 42'' W 42'' W 42'' W 42'' W 42'' W 42'' W 42'' W 4'' UD 4'' UD 4'' UD 4'' UD 4'' UD8'' SS8'' SS10'' SS 10'' SS 10'' SS 10'' SS 8'' SS 8'' SS 8'' SS 8'' SS 8'' SS 8'' SS 8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W8'' W 8'' W 8'' W 8'' W 8'' W F F F F F F8'' SS8'' SS8'' SS8'' SS8'' SS 8'' SS UGE UGE UGE UGEUGEUGEUGEUGEUGEUGEUGEUGEUGE UGE UGEUGEUGEUGEUGE UGEUGEUGEUGEUGEUGEUGEUGEUGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGE UGEUGEUGE8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UD8'' UDW 60" W EE EEE E EEEEEEEE24" W24" W24" W24" W24" W24" W24" W24" W24" W24" W24" W60" W 60" W 60" W 60" W 60" W10" W10" W10" W10" W10" W10" W10" W10" W10" W10" W10" WFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOD D D D D D D D D D15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSS 18" SS18" SS18" SS18" SS18" SS18" SS18" SS18" SS18" SSUD UD UD UD UD UD UD UD UD UD UDMONITORI N G W E L L TRAFFIC R A T E D 8" SS 8" SS 8" SS 8" SS 8" SS8" SS 8" SS 8" SS 8" SS 8" W 8" W 8" W 8" W8" W 8" W 8" W8" W8" W8" W8" W 8" W 8" W 8" W 8" W8" W 8" W 8" W 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" W 8" W 8" W 8" W 8" W 8" WWWWSSS SSSWF FFFTFTFTFTFTFTFF W 8" W 8" W 8" W WFS8" W DFC NORTH FIELD LLC 981 LINDENMEIER ROAD EAST SUNIGA ROAD NO R TH L EM A Y A V E N U E GRAHAM JOHN C / GINGER L 1100 E VINE DRIVE 9TH STREETEX-INLET RIM = 4951.07 BOTTOM OF BOX = 4937.43 EX-STRM MH RIM = 4952.17 INV IN = 4942.96 (S) INV OUT = 4942.91 (N) EX-STRM MH RIM = 4953.11 BOTTOM OF BOX = 4942.18 EX-INLET GRATE = 4947.87 INV IN = 4942.06 (N) INV OUT = 4941.86 (S) EXISTING MANHOLE RISER A3 RIM = 4950.62 BOTTOM OF BOX = 4941.50 EXISTING 2" VERTICAL PIPE STMH INV IN = 4941.48 (W) INV OUT = 4941.28 (S) EX-INLET RIM = 4946.67 INV IN = 4941.87 (S) INV OUT = 4941.24 (N) EX-INLET RIM = 4946.75 INV OUT = 4941.81 (E) 125' ROW 15' SLOPE & UTILITY EASEMENT (REC. #20180037021) 15' SLOPE & UTILITY EASEMENT (REC. #20180037021) EX-INLET EXISTING CENTURY LINK FIBER-OPTIC UNDERGROUND LINE EXISTING FIRE HYDRANT 30' UTILITY & DRAINAGE EASEMENT (REC. #20200000602) GREELEY WATER LINE EASEMENT (WIDTH VARIES) (REC. #20080062293) 50' DRAINAGE & UTILITY EASEMENT (REC #20190075879 & #20180037022) EXISTING GREELEY 60" STEEL WATER LINE EXISTING AIR RELEASE VALVE 500-YEAR FLOODPLAIN BUILDING 1000 BUILDING 2000 BUILDING 3000 BUILDING 4000 BUILDING 5000 BUILDING 6000 DOG PARK CONNECT TO EX-SSMH RIM = 4953.71 INV IN = 4947.36 (N) INV OUT = 4947.27 (S) EX-SSMH RIM = 4952.70 INV IN = 4947.11 (N) INV OUT = 4947.01 (S) EX-SSMH RIM = 4953.53 INV IN = 4948.36 (W) INV IN = 4947.38 (N) INV OUT = 4947.38 (S) EXISTING NECCO BACKBONE STORM LINE A4 EX-SSMH RIM = 4954.03 INV IN = 4948.61 (W) NV IN = 4947.74 (N) INV OUT = 4947.74 (S) APPROXIMATELY 19.21 LF OF EXITING 15" PVC SANITARY SEWER @ 0.10% AREA INLET (TYP.) STORM DRAIN (TYP.) STORM DRAIN (TYP.) STORM DRAIN MANHOLE (TYP.) STORM DRAIN MANHOLE (TYP.) 30' UTILITY EASEMENT WATER QUALITY BASIN w/ WEIR FIRE SERVICE (TYP.) WATER SERVICE (TYP.) SANITARY SERVICE (TYP.) SANITARY SEWER MANHOLE (TYP.) CONNECT TO EXISTING 10" ELCO WATER LINE CONNECT TO EXISTING 15" SANITARY SEWER INSTALL MANHOLE STORM DRAIN (TYP.) WATER METER (TYP.) ELECTRICAL TRANSFORMER (TYP.) EXISTING CITY OF FORT COLLINS 24" PVC WATER MAINEXISTING ELCO 10" PVC WATER MAIN EXISTING FIRE HYDRANT FIRE HYDRANT (TYP.) EXISTING NECCO BACKBONE STORM LINE A1 12'x4' RCBC @ 0.21% STORMTECH MC-7200 SYSTEM 63 ISOLATOR CHAMBERS & 441 DETENTION CHAMBERS 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT 26' D, A, U, EA EASEMENT D, A, U, EA EASEMENT DRAINAGE EASEMENT (WIDTH VARIES)205.3 LF 18" PVC @ 0.11%569.8 LF 18" PVC @ 0.03%382.0 LF 15" CLAY @ 0.13%217.5 LF 15" CLAY @ 0.11%EX-SSMH RIM=4952.65 INV IN=4946.90 (N) INV IN=4947.48 (W) 8" INV OUT=4946.80 (S) EX-STRM MH RIM = 4951.44 INV IN = 4943.74 (N) INV OUT = 4943.54 (S) WATER SERVICE (TYP.)WATER METER (TYP.) SANITARY SERVICE (TYP.) SANITARY SERVICE (TYP.) STORM DRAIN FOR ROOF LEADER CONNECTIONS FIRE HYDRANT (TYP.) 2.48' ADDITIONAL ROW 2.48' ADDITIONAL ROW 10' MIN. SEPARATION 10' MIN. SEPARATION AREA INLET (TYP.) ELECTRICAL TRANSFORMER (TYP.) STORM DRAIN FOR ROOF LEADER CONNECTIONS STORM DRAIN FOR ROOF LEADER CONNECTIONS 15' SLOPE & UTILITY EASEMENT (REC. #20180037021) STORM DRAIN FOR ROOF LEADER CONNECTIONS SheetCROWNE AT SUNIGAThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 9 OU1 OVERALL UTILITY PLAN6 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 8" SS NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER DISTRICT, WATER DISTRIBUTION SYSTEM DESIGN CRITERIA MANUAL, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 2" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE 8" W EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV TF EXISTING FIBER-OPTIC PEDESTAL PROPOSED TRANSFORMER EXCLUSIVE PERMANENT ELCO WATER LINE EASEMENT (REC. #20080070035) (WIDTH VARIES)