HomeMy WebLinkAboutJEROME STREET STATION - FDP230006 - DOCUMENT MARKUPS - ROUND 3 - UTILITY PLANS (2)VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
TRAFFIC
VAULT
VAULT
ELEC
HY DVAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELECHYDHYDHYDCONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
V.P.
V.P.
S
S
D
D
S
S
S
D
D
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXWWWWWWWWWWWW EEWWWWWWWWE EGGGGGGGGGGGGGGGG
SSSSSSSSSSSSSSSSSSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SS
VAULT
ELEC
HY DD
S
CONTROL
IRR
CONTROL
IRR
GAS
XXXXXXXXXXXXXEEEEEFOFOFOFOFOGGGWWXXSSS
S
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHUOHUOHUWGGGGGGGGGGGGGGGG
G
E
E
E ELID
MHE
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXGASSSSSSSSSSSSSSSSSSSSSS
E E E E E
D
ALL KINDS INVESTMENTS,
910 N COLLEGE AVE
REMOVE EXISTING 8' CONCRETE PAN
REMOVE & REPLACE
EXISTING 8' CONCRETE PAN
REMOVE & REPLACE
EXISTING PEDESTRIAN RAMP
REMOVE & REPLACE
EXISTING PEDESTRIAN RAMP
REMOVE & REPLACE
EXISTING PEDESTRIAN RAMP
REMOVE & REPLACE
EXISTING PEDESTRIAN RAMP
REMOVE EXISTING BLOW OFF HYDRANT
CLOSE VALVE AT CONNECTION IN STREET
REMOVE EXISTING BLOW OFF HYDRANT
REMOVE EXISTING 3' CONCRETE
TRICKLE CHANNEL
EXISTING TREE
TO REMAIN (TYP.)
REMOVE EXISTING METAL POSTS (TYP.)
REMOVE EXISTING GRAVEL ROAD
EXISTING SIGN
EXISTING FES
EXISTING 18" RCP
EX-STORM MH
RIM=4964.97
INV OUT=4960.75 (S)
EXISTING FES
EX-STORM MH
RIM=4965.35
EX-STORM MH
RIM=4965.34
EX-STORM MH
RIM=4965.18
INV OUT=4961.45 (S)
24" RCP
EX-STORM MH
RIM=4970.03
INV=4959.43 (W, E)
EX-STORM MH
RIM=4970.54
INV=4958.66 (W, E)
EXISTING 36" RCP (STORM)
EX-CHAIN LINK
FENCE
EX-SAN MH
RIM=4968.77
INV IN=4960.95 (E)
INV OUT=4960.87 (S)
EX-SAN MH
RIM=4967.69
INV IN=4959.99 (N)
INV OUT=4959.82 (S)
EX-SAN MH
RIM=4966.47
INV=4958.78 (N, E, SE)
EX-SAN MH
RIM=4963.95
INV IN=4956.53 (N)
INV IN=4956.25 (W)
INV OUT=4955.75 (S)
EX-SAN MH
RIM=4964.48
INV IN=4957.66 (N)
INV OUT=4957.48 (E)
EX-SAN MH
RIM=4965.40
INV=4958.74 (N, S)
EX-SAN MH
RIM=4966.71
INV=4960.03 (W, S)
EXISTING SAN MH
RIM=4964.63
INV IN=4957.59 (NW, E)
INV OUT=4957.42 (S)
EX-SAN MH
RIM=4964.02
INV IN=4958.97 (N)
INV OUT=4957.74 (S)
LOT 1, BLOCK 1,
WILL
SUBDIVISION
EX-30' UTILITY & DRAINAGE
EASEMENTNORTH COLLEGE AVENUE(PUBLIC R.O.W. VARIES)EXISTING 24" SANITARY PVC
EXISTING 15'
UTILITY EASEMENT
EXISTING FIRE HYDRANT
BOWL FORT COLLINS LLC,
830 N COLLEGE AVE
LAND W PROPERTIES
742 N COLLEGE AVE
EXISTING STREET
LIGHT (TYP.)
EXISTING 8" WATER LINE
EXISTING GAS LINE
EXISTING FIRE HYDRANT
EXISTING ELECTRICAL VAULT (TYP.)
EXISTING 9'
UTILITY EASEMENT
EXISTING 30' GAS
LINE EASEMENT
LAKE CANAL COMPANY EASEMENT
PER PLAT OF OLD TOWN NORTH
50'
-
EXISTING UNDERGROUND
ELECTRIC UTILITY
EXISTING TREE
TO REMAIN (TYP.)
EXISTING 8" WATER LINE
VACATE EXISTING TEMPORARY EMERGENCY
ACCESS EASEMENT (WIDTH VARIES)
TEMPORARY TURN-AROUND EASEMENT
PER PLAT OF OLD TOWN NORTH
TO BE VACATED
REMOVE EXISTING
CONCRETE PAD
& STORM INLETS
EX-STORM LINE
REMOVE EX-CHAIN
LINK FENCE
30' UTILITY EASEMENT
PER WILL SUBDIVISION
VACATE EXISTING 20' TEMPORARY
EMERGENCY ACCESS EASEMENT
EXISTING SIDEWALK AND
CHASE TO REMAIN
CONTRACTOR TO ENSURE EXISTING
SANITARY LINE REMAINS UNDAMAGED
DURING REMOVAL OF TREES IN THIS AREA
TRACT JJJ
TO BE VACATED
LAKE CANAL EASEMENT PER
PLAT OF OLD TOWN NORTH
REMOVE EXISTING VERTICAL PIPE
100 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN
500 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
NHBZ-BOUNDARY LINE
76'
ROW
DEAD TREES TO BE REMOVED
EXISTING 9'
UTILITY EASEMENT
EXISTING 9'
UTILITY EASEMENT
EXISTING 9'
UTILITY EASEMENT
20' DRAINAGE
EASEMENT
REMOVE & REPLACE
EXISTING CURB & GUTTER
REMOVE & REPLACE
EXISTING CURB & GUTTER
5'±
5'
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
EX1 DEMOLITION PLANEXISTING CONDITIONS &4
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
NOTES:
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
EXISTING CABLE CTV
EXISTING FIBER OPTIC FO
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE.
4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
6.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ.
EXISTING OVERHEAD UTILITY OHE
ORIGINAL FIELD SURVEY:
NORTHERN ENGINEERING
PROJECT NO. 1124-005
DATE: JUNE 16, 2020
EXISTING GRAVEL (TO BE REMOVED)
EXISTING CONCRETE (TO BE DEMOED)
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
NHBZ-BOUNDARY LINE
EXISTING STORM SEWER SS
B
BBBBBB
B
B
B
B
B BBBBBBB
BBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBBB BBBBBVAULT
CABLE
VAULT
CABLE
VAULT
CABLE
VAULT
CABLE
VAULT
CABLE
VAULT
CABLE
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXCONTROL
IRR
CONTROL
IRR
GASFOFO
FOFOFOOHUOHUOHU/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GAS
24'
-
BOWL FORT COLLINS LLC
830 N COLLEGE AVE
LAND W PROPERTIES
742 N COLLEGE AVE
76'
ROW
50'
-15' SIDEWALK30' EMERGENCY ACCESS
& UTILITY EASEMENT
5' SIDEWALK20'
-
EXISTING 30' UTILITY
& DRAINAGE EASEMENT
PROPOSED 30' SEWER
LINE EASEMENT
LAKE CANAL COMPANY EASEMENT
PER PLAT OF OLD TOWN NORTH
EXISTING 10'
DRAINAGE EASEMENT
LAKE CANAL EASEMENT PER
PLAT OF OLD TOWN NORTH
EXISTING 30' GAS
LINE EASEMENT
26' -
8' SIDEWALK
8' SIDEWALK
15' CRUSHER FINES TRAIL
5' SIDE
W
A
L
K
5' SIDEWALK
15' ACCESS/SIDEWALK
5' SIDE
W
A
L
K
5' SIDEWALK 5' SIDEWALK
5' SIDEWALK 5' SIDEWALK
5' SIDEWALK
20'
-
20' EMERGENCY ACCESS
& UTILITY EASEMENT
EMERGENCY ACCESS
& UTILITY EASEMENT
(WIDTH VARIES)
UTILITY & MAINTENANCE
EASEMENT (WIDTH VARIES)
26' EMERGENCY
ACCESS EASEMENT PEDESTRIAN WALKWAYBUILDING 1
5' SIDEWALKNORTH COLLEGE AVENUE(PUBLIC R.O.W. VARIES)100 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN100 YR FLOODPLAIN
100 YR FLOODPLAIN
PROPOSED 25'
UTILITY EASEMENT
15' ACCESS/SIDEWALK
6' UTILITY EASEMENT
6' UTILITY EASEMENT
EXISTING 15'
DRAINAGE
EASEMENT
EXISTING 30'
UTILITY EASEMENT
9'
UTILITY
EASEMENT
12' TR
A
V
E
L
L
A
N
E
12' TR
A
V
E
L
L
A
N
E
44' ROW 5' SIDEWALK
BUILDING 2 BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7
BUILDING 8
BUILDING 9
BUILDING 10
BUILDING 11
BUILDING 12
TRACT A
TRACT A
TRACT B
TRACT B
PROPOSED 25'
UTILITY EASEMENT
EXISTING 15'
UTILITY EASEMENT
20' DRAINAGE
EASEMENT
PUBLIC ACCESS
EASEMENT
(WIDTH VARIES)
PASCA
L
S
T
R
E
E
T JEROME STREET
OSIANDER
STREET
CAJETAN
STREET
PASCA
L
STREE
T
8' PAN
8' PAN
PEDESTRIAN
RAMPS (TYP.)
PEDESTRIAN RAMP
PROJECT BOUNDARY
PEDESTRIAN
RAMP (TYP.)
PEDESTRIAN RAMP
PROPOSED SIDEWALK
CHASE
PROPOSED
SIDEWALK CHASE
PROPOSED SIDEWALK
CHASE
PROPOSED DRIVEOVER
CURB & GUTTER
PROPOSED DRIVEOVER
CURB & GUTTER
PROPOSED DRIVEOVER
CURB & GUTTER
PROPOSED DRIVEOVER
CURB & GUTTER
PROPOSED DRIVEOVER
CURB & GUTTER
PROPOSED
1' CONCRETE
CHASE
PROPOSED
CURB CUT
PROPOSED 10'
WALK (TYP.)
PROPOSED 5' WALK
(TYP.)
1
2
2
2
2
2
2
2
2
1
PROPOSED 10'
WALK (TYP.)
PROPOSED SIDEWALK
CHASEPROPOSED SIDEWALK
CHASE
2
2
2
TYPE-III BARRICADE
(OR OTHER PERMANENT
TYPE, BY OWNER)
TYPE-III BARRICADE
PARKING STALL STRIPING (TYP.)
4" WHITE STRIPE AS PER LCUASS STANDARDS
PARKING STALL STRIPING (TYP.)
4" WHITE STRIPE AS PER LCUASS STANDARDS
PROPOSED 2' CURB CUT
& CONCRETE CHASE
1
3
5' SIDEWALK
4
PROPOSED 2' CURB CUT
& CONCRETE CHASE
PROPOSED 2' CURB CUT
& CONCRETE CHASE
PROPOSED 2' CURB CUT
& CONCRETE CHASE
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
PV1 PAVING PLAN5
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
EASEMENT LINE
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER THE CITY OF FORT COLLINS STANDARDS AND
PROJECT SPECIFICATION MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL
REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET
STANDARDS REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO LARIMER COUNTY URBAN AREA STREET STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED
IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
7.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
/ / / / / / / /PROPOSED EDGE OF PAVEMENT
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
CONCRETE PAVING
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
CRUSHER FINES TRAIL
PROPOSED LOT LINE
PROPOSED ROW
EXISTING EASEMENT LINE
1 2
SIGNS:
P0TS
FIRE
LANE
NO
PARKING
BY ORDER OF THE
FIRE MARSHAL
STANDARD
FIRE LANE SIGN DETAIL
18"
2"
1 1/2"
3/4"
12"
(FORT COLLINS ONLY)
NOTE:
INCLUDE "PRIVATELY MAINTAINED"
STREET NAME SIGN AT CAJETAN
STREET ENTRANCE; STANDARD
STREET NAME SIGN AT PASCAL
RESERVED
PARKING
3
VAN-
ACCESSIBLE
RESERVED
PARKING
4
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
TRAFFIC
VAULT
VAULT
ELEC
HY DVAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELECHYDCONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
S
D
D
S
S
S
D
D
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXWWWWWWWWWWWW EEWWWWWWWWE EGGGGGGGGGGGGGGGG
SSSSSSSSSSSSSSSSSSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SS
VAULT
ELEC
HY DD
S
CONTROL
IRR
CONTROL
IRR
GASEE
EEEFOFOFOFOFOGGGWWSSS
S
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHUOHUOHUWGGGGGGGGGGGGGGGG
G
E
E
E ELID
MHE
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GASSSSSSSSSSSSSSSSSSSSSS
E E E E E
D
B
BBBBBB
B
B
B
B
B BBBBBBB
BBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBBB BBBBBG G GGEEEEEEEEEEEEEEEEEEEEEEE
E E E E
E
E
E
E
E E
E
UDGG G G G
G
GEEE
E
E
E
E
E
UD
UD
UDGGE E
G
G
E
E
NEW MANHOLE IN EXISTING
SANITARY LINE
SANITARY SEWER
MANHOLE (TYP.)
EXISTING SANITARY SEWER
24'
FL-FL
CONNECT TO EXISTING SANITARY MHNORTH COLLEGE AVENUEEXISTING 15'
UTILITY EASEMENT
EXISTING 9'
UTILITY EASEMENT
EXISTING 30' GAS
LINE EASEMENT
LAKE CANAL COMPANY EASEMENT
PER PLAT OF OLD TOWN NORTH
LAKE CANAL EASEMENT PER
PLAT OF OLD TOWN NORTH
PROPOSED
GAS LINE
CONNECTION
(NORTH)
PROPOSED UNDERGROUND
ELECTRICAL UTILITY
EXISTING 8" WATER LINE
EXISTING FIRE HYDRANT
PROPOSED ELECTRICAL
TRANSFORMER (TYP.)
NEW MH/SANITARY PIPE FLOWS
EAST, CONNECTS TO EXISTING
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED FIRE HYDRANT
20'
FL-FL
20'
FL-FL
26'
FL-FL
EXISTING STORM
DRAIN
PROPOSED
CURB CUTPROPOSED RAIN GARDEN
& UNDERDRAIN
EXISTING GAS LINE
PROPOSED RAIN
GARDEN & UNDERDRAIN
PROPOSED RAIN GARDEN
& UNDERDRAIN
CONNECT TO EXISTING
WATER LINE
CONNECT TO EXISTING
WATER MAIN
CONNECT TO EXISTING
WATER MAIN
SCOUR-STOP
PROTECTION
20' EMERGENCY
ACCESS EASEMENT
26' EMERGENCY
ACCESS EASEMENT
100 YR FLOODPLAIN
500 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
100 YR FLOODPLAIN 500 YR FLOODPLAIN
PROPOSED
DETENTION
POND 1
EXISTING 30' UTILITY
& DRAINAGE EASEMENT
PROPOSED 30' SEWER
LINE EASEMENT
PROPOSED 25'
UTILITY EASEMENT
5' UTILITY
EASEMENT
EXISTING 15'
DRAINAGE
EASEMENT
EXISTING 30'
UTILITY EASEMENT
ELECTRIC SERVICES EXTENDING FROM
TRANSFORMERS TO BE PRIVATE (TYP.)
PROPOSED
BLOWOFF
HYDRANT
44'
ROW
76'
ROW
50'
FL-FL
BY OTHERS
SANITARY SEWER
PROPOSED
GAS LINE
BUILDING 1
BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7
BUILDING 8
BUILDING 9
BUILDING 10
BUILDING 11
BUILDING 12
TRACT A
TRACT A
TRACT B
TRACT B
ALL KINDS INVESTMENTS,
910 N COLLEGE AVE
BOWL FORT COLLINS LLC
830 N COLLEGE AVE
LAND W PROPERTIES
742 N COLLEGE AVE
PROPOSED CULVERT
WATER LINE A
SEE SHEET WT1
STORM DRAIN A
SEE SHEET ST1
SANITARY SEWER A4
SEE SHEET SS2
SANITARY SEWER A
SEE SHEET SS1
SANITARY SEWER A4
SEE SHEET SS2
SANITARY SEWER A4
SEE SHEET SS2
SANITARY SEWER A4-5
SEE SHEET SS3
WATER LINE C
SEE SHEET WT2
WATER LINE B
SEE SHEET WT2
PROPOSED
DETENTION
POND 2
20' DRAINAGE
EASEMENT
20' EMERGENCY
ACCESS EASEMENT
PROPOSED CULVERT
PROPOSED CULVERT
PROPOSED
CULVERT (TYP)
PASCA
L
S
T
R
E
E
T JEROME STREET
EAST SUNIGA ROAD
OSIANDER
STREET
CAJETAN
STREET
PASCA
L
STREE
T
PUBLIC ACCESS
EASEMENT
(WIDTH VARIES)
PROPOSED CURB CUT &
CONCRETE CHASE
PROPOSED CURB CUT &
CONCRETE CHASE
PROPOSED CURB CUT &
CONCRETE CHASE
PROPOSED CURB CUT &
CONCRETE CHASE
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
OU1 OVERALL UTILITY PLAN6
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
NOTES:
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES
WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO
MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS
SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL
DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES
WATER AND WASTEWATER DESIGN CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE
COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.GANGED WATER SERVICE CONNECTION AND STOP VALVE AT MAIN CONNECTION
SHALL BE 1-1/2". ALL WATER SERVICES SHALL BE 1" UNLESS OTHERWISE NOTED.
12.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100 YEAR
AND 500 YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE.
13.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES,
SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK,
LANDSCAPING, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE
PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS.
14.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED USE STRUCTURES IS PROHIBITED IN
THE POUDRE RIVER 100YEAR FLOODPLAIN.
15.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER
PERMANENT OR TEMPORARY IS PROHIBITED IN THE 100YEAR FLOODPLAIN.
16.AT RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND
GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100YEAR
FLOODPLAIN.
17.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT
COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE
ISSUED FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A
LOMR IS APPROVED THROUGH FEMA. IT IS AT OUR OWN RISK THAT WE CONTINUE
THROUGH THE PLANNING PROCESS.
18.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ.
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
PROPOSED TRANSFORMER
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
FPROPOSED FIRE SERVICE
UDPROPOSED UNDERDRAIN
EXISTING TELEPHONE PEDESTAL
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
TRAFFIC
VAULT
VAULT
ELEC
HY DVAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
C.O.H2OCONTROL
IRR
CONTROL
IRR
C.O.
C.O.C.O.CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
S
D
D
S
S
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX
XXXXXXXXWWWWWWWW
WWWWWWEEWW
WWWWWWWWWWWWW W
W
W W W W W W
W WEEE
EGGGGGGGGGGGGGGG G G
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SS SS
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
GGGGGGGGGGGGGGG G G
SSSSSSSSSSSSSSS
E E E E E E E E
EBBBBBG G G GGGGE
EEEEEEEEEEEEEEEEEEEEGEEE E
E E E E E E
EE
E
E
E
E
E
E
GG G
G
G
E
E
E
E E
W
WWWWWWSSSSS
WWWWWWWWWWWWWWWWWW W
SSSSSSSSSSSSSSSSSSSSSSSWW S
SWWWSSSSSWWWWWWWW
EXISTING 15'
UTILITY EASEMENT
50'
FL-FL
EXISTING 9'
UTILITY EASEMENT
ALL KINDS INVESTMENTS,
910 N COLLEGE AVE
BOWL FORT COLLINS LLC
830 N COLLEGE AVE
CONNECT TO EXISTING 8" WATER MAIN
CONNECT
TO EXISTING 8" WATER LINE
EX-STORM MH
RIM=4970.54
INV=4958.66 (W, E)
EXISTING 36" RCP STORM LINE
EX-SSMH
RIM=4968.77
INV IN=4960.95 (E)
INV OUT=4960.87 (S)
EX-SAN MH
RIM=4966.71
INV=4960.03 (W, S)
EXISTING 24"
SANITARY PVC
EXISTING 8" WATER LINE
PROPOSED ELECTRICAL
TRANSFORMER (TYP.)
PROPOSED WATER
SERVICE (TYP.)
PROPOSED SANITARY
SEWER SERVICE (TYP.)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
PROPOSED 25'
UTILITY EASEMENT
EXISTING 20' SEWER
LINE EASEMENT
76'
ROW
PROPOSED ELECTRIC SERVICE EXTENDING
FROM TRANSFORMER BOX PRIVATE (TYP.)
BUILDING 1
BUILDING 2
BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7
CURB STOP (TYP)
GANGED WATER SERVICE CONNECTION
STOP VALVE AT MAIN CONNECTION
& EACH CONNECTION EXTERIOR TO HOUSE (TYP.)
TRACT A
SANITARY SEWER A4
SEE SHEET SS2
SANITARY SEWER A4-5
SEE SHEET SS3
WATER LINE B
SEE SHEET WT2
WATER LINE B
SEE SHEET WT2
PROPOSED FH
PROPOSED FH
SANITARY SEWER A4
SEE SHEET SS2
SSMH A4-2
SSMH A4-3
SSMH A4-4
SSMH A4-5 SSMH A4-5ESSMH A4-5W
JEROME STREET
EAST SUNIGA ROAD
OSIANDER
STREET
CAJETAN
STREET
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
U1 UTILITY PLAN7
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
NOTES:
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
FPROPOSED FIRE SERVICE
UDPROPOSED UNDERDRAIN
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES
WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO
MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS
SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL
DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES
WATER AND WASTEWATER DESIGN CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE
COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.GANGED WATER SERVICE CONNECTION AND STOP VALVE AT MAIN CONNECTION
SHALL BE 1-1/2". ALL WATER SERVICES SHALL BE 1" UNLESS OTHERWISE NOTED.
12.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100 YEAR
AND 500 YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE.
13.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES,
SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK,
LANDSCAPING, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE
PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS.
14.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED USE STRUCTURES IS PROHIBITED IN
THE POUDRE RIVER 100YEAR FLOODPLAIN.
15.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER
PERMANENT OR TEMPORARY IS PROHIBITED IN THE 100YEAR FLOODPLAIN.
16.AT RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND
GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100YEAR
FLOODPLAIN.
17.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT
COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE
ISSUED FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A
LOMR IS APPROVED THROUGH FEMA. IT IS AT OUR OWN RISK THAT WE CONTINUE
THROUGH THE PLANNING PROCESS.
18.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ.
PROPOSED TRANSFORMER
EXISTING TELEPHONE PEDESTAL
U1
U2
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
KEYMAPN. COLLEGE AVENUECAJETA
N
S
T
.JEROME STREETE. VINE DRIVE
VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELECHYDS
S
D
D
D/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /WWWWWWWWWWWWWW EGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
S
GAS
WXGGSSSSSSGGS
S
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHUOHUOHUOHUOHUOHUWWWGGGGGGGGGGGGGGGGGG
G
E
EEMH/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GASOHUSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSD
B
BBBB
BB
B
B
B
B
BBBBBBBB
BBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBB
BBBBBBEEEEEEEEEEEEEEEEEEEEEGEE
EE
E
E
E
E
E
G
UD UD UD UDGG
G G G G G G G
G
G
G
EEEEE
E
E
E
E
E
E
E
E
E
UD
UD
UD
UD
UDUDGGGGE E E
G G
G
G
E
EWW
WWWWWWWWSSSSSSSSSSW WWW
WWWWWWWWWWSSSSS
SSSS
SSS
SSSSS S
S
SSSSWWWWWWWWWWWWWS SSSSWSSSWWW26'
FL-FL
EXISTING 9'
UTILITY EASEMENT
EXISTING 30' GAS
LINE EASEMENT
LAKE CANAL COMPANY EASEMENT
PER PLAT OF OLD TOWN NORTH
LAKE CANAL EASEMENT PER
PLAT OF OLD TOWN NORTH
BOWL FORT COLLINS LLC
830 N COLLEGE AVE
PROPOSED
POND
CONNECT
TO EXISTING 8" WATER MAIN
11.25° BEND (W)
N:134908.72
E:195609.34
SSMH A3
SSMH A2
SSMH A
SSMH A1
SSMH A5
EXISTING SANITARY SEWER
EXISTING
STORM FES
AND PIPING
EXISTING STORM LINE
EXISTING 18" RCP
24" RCP
EX-SAN MH
RIM=4963.95
INV IN=4956.53 (N)
INV IN=4956.25 (W)
INV OUT=4955.75 (S)
SAN MH
RIM=4964.63
INV IN=4957.59 (NW, E)
INV OUT=4957.42 (S)
EXISTING FIRE HYDRANT
EXISTING STREET
LIGHT (TYP.)
EXISTING 8" WATER LINE
EXISTING UNDERGROUND
ELECTRIC UTILITY
PROPOSED TRANSFORMER (TYP.)
PROPOSED CULVERT
1-1/2" IRRIGATION
WATER SERVICE
AND METER
PROPOSED RAIN GARDEN
& UNDERDRAIN
PROPOSED RAIN GARDEN
& UNDERDRAIN
PROPOSED WATER
SERVICE (TYP.)
CONCRETE
WEIR
CONCRETE
WEIR
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
PROPOSED RAIN GARDEN
& UNDERDRAIN
EXISTING 30' UTILITY
& DRAINAGE EASEMENT
PROPOSED 30' SEWER
LINE EASEMENT
EXISTING 10'
DRAINAGE EASEMENT
PROPOSED 25'
UTILITY EASEMENT
5' UTILITY
EASEMENT
EXISTING 20' SEWER
LINE EASEMENT
EXISTING 20' SEWER
LINE EASEMENT
EXISTING 15'
DRAINAGE
EASEMENT
EXISTING 30'
UTILITY EASEMENT
PROPOSED SANITARY SEWER
BY OTHERS
CONCRETE
WEIR
EXISTING STORM LINE
BUILDING 6
BUILDING 7
BUILDING 8
BUILDING 9
BUILDING 10
BUILDING 11
BUILDING 12
TRACT A
TRACT B
TRACT B
WATER LINE A
SEE SHEET WT1
STORM DRAIN A
SEE SHEET ST1
SANITARY SEWER A4
SEE SHEET SS2
SANITARY SEWER A
SEE SHEET SS1
SANITARY SEWER A
SEE SHEET SS1
PROPOSED FH
PROPOSED
POND
EXISTING INLET
SCOUR-STOP
PROTECTION
SSMH A4
SSMH A4-1
SSMH A4-2
SSMH A4-3
GANGED WATER SERVICE CONNECTION
CORP STOP VALVE AT MAIN CONNECTION
& EACH CONNECTION EXTERIOR TO HOUSE (TYP.)
SSMH EX(24'')-1
PROPOSED STREET
LIGHT (TYP.)
PROPOSED CULVERT
PROPOSED CULVERT
PROPOSED CULVERT
PASCA
L
S
T
R
E
E
T JEROME STREET
PASCA
L
STREE
T
PUBLIC ACCESS
EASEMENT
(WIDTH VARIES)
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
U2 UTILITY PLAN8
NORTH
( IN FEET )
1 inch = ft.
Feet03030
30
60 90
KEYMAPN. COLLEGE AVENUECAJETA
N
S
T
.JEROME STREETE. VINE DRIVE
NOTES:
EXISTING LOT LINE
EASEMENT LINE
SPROPOSED SEWER SERVICE
WPROPOSED WATER SERVICE
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
G
T
EXISTING STORM SEWER
EXISTING TELEPHONE
EXISTING GAS
EXISTING SANITARY SEWER
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPERTY BOUNDARY
PROPOSED STREET LIGHT
W
SS
PROPOSED LOT LINE
PROPOSED ROW
EXISTING ROW
EXISTING CABLE CTV
FPROPOSED FIRE SERVICE
UDPROPOSED UNDERDRAIN
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES
WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO
MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS
SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL
DEFLECTIONS.
3.ALL SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES
WATER AND WASTEWATER DESIGN CRITERIA MANUAL, LATEST EDITION.
4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
5.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5.5' WATER LINE
COVER FROM FINISHED GRADE TO TOP OF PIPE.
6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS
SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND
ARE SUBJECT TO CHANGE IN THE FIELD.
7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL
SANITARY SEWER MAINS, WATER MAINS & SERVICES.
8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS.
10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 1 4"
BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO
PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
11.GANGED WATER SERVICE CONNECTION AND STOP VALVE AT MAIN CONNECTION
SHALL BE 1-1/2". ALL WATER SERVICES SHALL BE 1" UNLESS OTHERWISE NOTED.
12.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100 YEAR
AND 500 YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE.
13.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES,
SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK,
LANDSCAPING, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE
PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS.
14.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED USE STRUCTURES IS PROHIBITED IN
THE POUDRE RIVER 100YEAR FLOODPLAIN.
15.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER
PERMANENT OR TEMPORARY IS PROHIBITED IN THE 100YEAR FLOODPLAIN.
16.AT RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND
GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100YEAR
FLOODPLAIN.
17.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT
COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE
ISSUED FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A
LOMR IS APPROVED THROUGH FEMA. IT IS AT OUR OWN RISK THAT WE CONTINUE
THROUGH THE PLANNING PROCESS.
18.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ.
PROPOSED TRANSFORMER
EXISTING TELEPHONE PEDESTAL
U1
U2
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
B
BBBBBB
B
B
B
B
B BBBBBBB
BBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBBB BBBBBVAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
TRAFFIC
VAULT
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
S
S
D
D
S
S
S
D
D
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXVAULT
ELEC
D
S
CONTROL
IRR
CONTROL
IRR
GASFOFO
FOFOFOS
S
SOHUOHUOHULID
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GAS
S
D
UD
UD
UD
UDB
BBBBBB
B
B
B
B
B BBBBBBB
BBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBBB BBBBBALL KINDS INVESTMENTS,
910 N COLLEGE AVE
NORTH COLLEGE AVENUEBOWL FORT COLLINS LLC
830 N COLLEGE AVE
LAND W PROPERTIES
742 N COLLEGE AVE
DETENTION
POND 2
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
500 YR FLOODPLAIN
(CURRENT EFFECTIVE)
100 YR FLOODPLAIN
(CURRENT EFFECTIVE)
BUILDING 1
BUILDING 2 BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7
BUILDING 8
BUILDING 9
BUILDING 10
BUILDING 11
BUILDING 12
TRACT A
TRACT B
TRACT B
PASCA
L
S
T
R
E
E
T
DETENTION
POND 1
JEROME STREET
OSIANDER
STREET
CAJETAN
STREET
PASCA
L
STREE
T
EXISTING 3-18" RCP
STORM LINES
PROPOSED SIDEWALK
CHASE (TYP.)
PROPOSED
CURB CUT
PROPOSED CHASE
RAIN GARDEN 1
SEE SHEET RG1
RAIN GARDEN 2
SEE SHEET RG1
RAIN GARDEN 3
SEE SHEET RG2
SWALE SECTIONS
SWALE SUMMARY TABLE
A1A1
A2A2
A3A3
A4
A4
A6
A6
A5A5
EAST SUNIGA ROAD
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
OG1 OVERALL GRADING PLAN15
NORTH
( IN FEET )
1 inch = ft.
Feet05050
50
100 150
KEYMAPN. COLLEGE AVENUECAJETA
N
S
T
.JEROME STREETE. VINE DRIVE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED SPOT ELEVATION
PROPOSED SLOPES
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS,
UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION.
3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR
BENCHMARK REFERENCES.
4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS.
5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH
DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE,
GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL
MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS
AND PLOT PLAN DESIGN SHALL BEET FHA GRADING GUIDELINES AND BUILDING
CODE REQUIREMENTS.
6.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100-YEAR AND
500-YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE FLOODPLAIN
MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL
CODE.
7.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES, SIDEWALK
OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK, LANDSCAPING,
ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT, THE
APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS.
8.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED-USE STRUCTURES IS PROHIBITED IN
THE POUDRE RIVER 100-YEAR FLOODPLAIN.
9.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER PERMANENT
OR TEMPORARY IS PROHIBITED IN THE 100-YEAR FLOODPLAIN.
10.AT-RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND
GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE
100-YEARFLOODPLAIN.
11.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT
COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE ISSUED
FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A LOMR IS
APPROVED THROUGH FEMA. IT IS AT OUR OWN RISK THAT WE CONTINUE THROUGH
THE PLANNING PROCESS.
12.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ
13.ADA VISITABLE UNITS INCLUDE ALL UNITS IN BUILDINGS 3, 5, 7, 8, 10, 11, AND 12.
NOTES:
PROPOSED STORM INLET
2.0%
(47.45
)
EXISTING SPOT ELEVATION
EXISTING LOT LINE
PROPOSED CONCRETE
CROSS PAN (TYP.)
33.43
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPOSED RIGHT OF WAY
LEGEND:
PROPOSED GRADE BREAK
PROPOSED STORM SEWER UD
G1
G2
SWALE SECTIONS
SWALE SUMMARY TABLE
SWALE ID MIN D MIN TW S1 (n:1)BW S2 (n:1)Q
A1 - A1 0.54 12.44 3.0 1.0 8.0 3.29
A2 - A2 0.79 11.32 4.0 1.0 4.0 6.58
A3 - A3 0.36 13.76 11.0 0.0 5.0 1.12
A4 - A4 0.62 6.72 3.0 0.0 3.0 3.04
A5 - A5 0.54 15.60 9.0 0.0 6.0 5.47
A6 - A6 0.77 25.40 4.0 0.0 16.0 15.00
B
BBBB
BB
B
B
B
B
BB BBBBBBBBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BB
BBBB
BBBVAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
TRAFFIC
VAULT
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC VAULT
CABLE
VAULT
ELEC
VAULT
CABLE
VAULT
ELEC
VAULT
ELEC
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRRD
D
D
D
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXEEEEVAULT
ELEC
D
CONTROL
IRR
CONTROL
IRR
GASEE
EEFOFOFOFOOHUOHUOHUE
E
E ELID
MHE
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GAS
E E E E E
D
UD
UD
UD
UD1.43 ac.
A
0.34 ac.
B
0.42 ac.
C1
1.12 ac.
C2
0.31 ac.
D
0.97 ac.
E1
0.29 ac.
E2
0.80 ac.
F
0.69 ac.
G
0.67 ac.
H
0.75 ac.
J1
0.17 ac.
J2
0.01 ac.
J
0.06 ac.
K
0.03 ac.
I 26'
-
EXISTING 30' UTILITY
& DRAINAGE EASEMENT
LAKE CANAL EASEMENT PER
PLAT OF OLD TOWN NORTH
EXISTING 30' GAS
LINE EASEMENT
LAKE CANAL COMPANY EASEMENT
PER PLAT OF OLD TOWN NORTHNORTH COLLEGE AVENUE(PUBLIC R.O.W. VARIES)100 YR FLOODPLAIN
100 YR FLOODPLAIN
500 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
j1
g
h
k
d
c2
b
j
f
a
e1
j2
i
c1
e2
BUILDING 1
BUILDING 2 BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7
BUILDING 8
BUILDING 9
BUILDING 10
BUILDING 11 BUILDING 12
TRACT A
TRACT A
TRACT B
TRACT B
PROPOSED 30' SEWER
LINE EASEMENT
PROPOSED 25'
UTILITY EASEMENT
PROPOSED 25'
UTILITY EASEMENT
EXISTING 15'
UTILITY EASEMENT
20' DRAINAGE
EASEMENT
EROSION
CONTROL BLANKET
EROSION
CONTROL BLANKET
EROSION
CONTROL BLANKET
PROJECT BOUNDARY
PROPOSED STORM LINE
PROPOSED STORM LINE
EXISTING STORM
DRAIN
SCOUR-STOP
(TYP.)
PROPOSED
1' CHANNEL (TYP.)
PROPOSED CURB CUT
A1
PROPOSED
RAIN GARDEN 1
PROPOSED
RAIN GARDEN 2
EXISTING CONCRETE CULVERT
CONCRETE
WEIR
CONCRETE
WEIR
PROPOSED
RAIN GARDEN 3
CONCRETE
WEIR
DETENTION POND 1
MAXIMUM RELEASE RATE=14.0 CFS
TOTAL VOLUME REQ'D = 0.07 AC-FT
TOTAL VOLUME PROVIDED= 0.07 AC-FT
100-YR WSEL=4964.56
DETENTION POND 2
MAXIMUM RELEASE RATE=19.36 CFS
TOTAL VOLUME REQ'D = 0.41 AC-FT
TOTAL VOLUME PROVIDED= 0.41 AC-FT
100-YR WSEL=4964.00
PROPOSED SIDEWALK
CHASE C1a
PROPOSED
SIDEWALK CHASE C2a
PROPOSED SIDEWALK
CHASE C1b
PROPOSED CULVERT
X' WALK (TYP)
PROPOSED CULVERT
PROPOSED CULVERT
X' WALK (TYP)
CONCRETE
WEIR
PROPOSED SIDEWALK
CHASE F1a
PROPOSED SIDEWALK
CHASE F1b
PROPOSED CULVERT
PROPOSED CULVERT
SCOUR-STOP 4'x4'
SCOUR-STOP 4'x4'
SCOUR-STOP 4'x4'
SCOUR-STOP 4'x4'
DR1DRAINAGE EXHIBIT34
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
A
DESIGN POINT
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
11
NOTES:
1.REFER TO THE FINAL DRAINAGE REPORT, DATED APRIL 11, 2023 FOR ADDITIONAL
INFORMATION.
2.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100 YEAR
AND 500 YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE
FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE.
3.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES,
SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK,
LANDSCAPING, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE
PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS.
4.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED USE STRUCTURES IS PROHIBITED
IN THE POUDRE RIVER 100_YEAR FLOODPLAIN.
5.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER
PERMANENT OR TEMPORARY IS PROHIBITED IN THE 100 YEAR FLOODPLAIN.
6.AT_RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND
GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100 YEAR
FLOODPLAIN.
7.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT
COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE
ISSUED FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL
A LOMR IS APPROVED THROUGH FEMA. IT IS AT APPLICANTS OWN RISK THAT THEY
CONTINUE THROUGH THE PLANNING PROCESS.
8.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NHBZ.
A
LEGEND:
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
UDPROPOSED UNDERDRAINC2C100Q2
(cfs)
Q100
(cfs)
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRR
CONTROL
IRRD
D
D
D
D
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXVAULT
ELEC
VAULT
ELEC
D
CONTROL
IRR
CONTROL
IRR
GAS
M FOFOFOFOFOEOHUOHU OHU OHUSSSSSSOHUOHUOHULID
MH
/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /GAS
D
??
1235
930
B
BBBB
BB
B
B
B
B
BBBBBBBBBBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBBBBBBBBUD
UD
UD
UDB
BBBB
BB
B
B
B
B
BBBBBBBBBBB
BB
BBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBB
BB
BBB
BBBBBBBBB4964.
2
3
(
N
A
V
D
8
8
)
ALL KINDS
INVESTMENTS,
910 N COLLEGE AVE,
BOWL FORT
COLLINS LLC
830 N COLLEGE AVE,
LAND W
PROPERTIES
742 N COLLEGE AVE
100 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN500 YR FLOODPLAIN100 YR FLOODPLAIN500 YR FLOODPLAIN
100 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
500 YR FLOODPLAIN
NHBZ - BOUNDARY LINE
500 YR FLOODPLAIN
500 YR FLOODPLAIN
FFE=68.00
FFE=67.28
FFE=69.47
FFE=68.64
FFE=69.06
FFE=68.91
FFE=68.92
FFE=69.70
FFE=69.95
FFE=71.29 FFE=71.50
FFE=72.22
BUILDING 1
BUILDING 2 BUILDING 3
BUILDING 4
BUILDING 5
BUILDING 6
BUILDING 7
BUILDING 8
BUILDING 9
BUILDING 10
BUILDING 11
BUILDING 124964.18 (NAV
D88)4966.1 (NAVD88)FP1FLOODPLAIN EXHIBIT35
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
SheetJEROME STREET STATIONNOT FOR CONSTRUCTIONREVIEW SETof 35
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
Original Field Survey:
Northern Engineering
Project No. 1124-005
Date: June 16, 2020
LEGEND:
PROPOSED CONTOUR
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPOSED STORM INLET
PROPOSED CONCRETE
CROSS PAN (TYP.)
PEDESTRIAN ACCESS RAMPS
PROPERTY BOUNDARY
NOTES:
FIELD SURVEY BY:
BENCHMARKS:
CROSS-SECTION (CSU CLOMR) 2446
5000ELEVATION NGVD 88
BASE FLOOD ELEVATION (CSU CLOMR)
100-YR FLOODPLAIN - (PER CSU CLOMR)
MINIMUM FINISHED FLOOR ELEVATION
(FFE) = C (FFE VARIES, SEE PLAN)
BASE FLOOD ELEVATION
(BFE) = A
MINIMUM MECH./ELEC. EQUIPMENT
ELEVATION = B
BASE FLOOD ELEVATION
(BFE) = A
24"
MIN.24"
MIN.
MECH. /
ELEC.
EQUIPMENT
FLOOD ELEVATION DETAIL
NTS
SLAB-ON-GRADE
NHBZ - BOUNDARY LINE
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100-YEAR AND 500-YEAR
POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE
SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES, SIDEWALK OR CURB &
GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK, LANDSCAPING, ETC.) MUST BE PRECEDED BY
AN APPROVED FLOODPLAIN USE PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND
APPROVED PLANS.
3.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED-USE STRUCTURES IS PROHIBITED IN THE POUDRE
RIVER 100-YEAR FLOODPLAIN.
4.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER PERMANENT OR
TEMPORARY IS PROHIBITED IN THE 100-YEAR FLOODPLAIN.
5.AT-RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND GOVERNMENT
SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN.
6.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT COMPLY WITH
THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE ISSUED FOR RESIDENTIAL
STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A LOMR IS APPROVED THROUGH FEMA. IT IS
AT APPLICANTS OWN RISK THAT THEY CONTINUE THROUGH THE PLANNING PROCESS.
7.REFER TO THE FINAL DRAINAGE REPORT, DATED APRIL 11, 2023 FOR ADDITIONAL INFORMATION.
PROJECT DATUM: NAVD88
CITY OF FORT COLLINS BENCHMARK 1-00
ON A CATCH BASIN AT THE SOUTHEAST CORNER OF VINE DR. AND COLLEGE AVE.
ELEV.=4968.74
CITY OF FORT COLLINS BENCHMARK 3-13
APPROX.40 FT SOUTH OF THE LINDEN ST. BRIDGE OVER THE POUDRE RIVER,
ON THE WEST SIDE OF LINDEN ST. , ON A STORM INLET.
ELEV.=4962.27
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR
VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.18'
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE WEST LINE LINE OF THE SOUTHWEST QUARTER
OF SECTION 1-7-69 AS BEARING SOUTH 00° 38' 34" WEST (ASSUMED BEARING)
AND MONUMENTED AS SHOWN ON PLAT.