Loading...
HomeMy WebLinkAboutPROSPECT SPORTS CLUB - PDP230009 - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORT (2) Soilogic, Inc. 3522 Draft Horse Court • Loveland, CO 80538 • (970) 535-6144 December 27, 2022 RB+B Architects, Inc. 315 E. Mountain Avenue, Suite 100 Fort Collins, Colorado 80524 Attn: Ms. Rebecca Spears Re: Water-Soluble Sulfate Testing Report Prospect Properties Basketball Facility Lot 5, Prospect Park East, P.U.D. 1601 Sharp Point Drive, Fort Collins, Colorado Soilogic # 22-1426 Ms. Spears: Soilogic Inc. (Soilogic) has received results of subcontracted water-soluble sulfate (WSS) testing completed for the referenced project. Results of the completed laboratory tests and associated geotechnical engineering recommendations are included with this report. Water-soluble sulfates (WSS) tests were completed by a subcontracted laboratory on two (2) representative samples of the subgrade soils which will likely be in contact with structural concrete. The sulfate concentrations measured in the samples varied from 0.0676 to 0.1942 percent by weight in soil. ACI rates the measured concentrations as being a negligible to moderate risk of concrete sulfate attack. For moderate sulfate exposure, ACI recommends the use of Type II cement, a maximum water cement ratio of 0.50 and minimum compressive strength of 4,000 psi for concrete members in contact with corrosive soils/water. Utilizing the proper cement type and water/cement ratio outlined above will not eliminate the potential for sulfate attack. Even concrete mixes utilizing Type V cement for ‘severe’ environments will deteriorate eventually under sulfate attack. Limiting the permeability of the concrete and good concrete consolidation and curing procedures are more important than cement type to reduce this risk. Air entrained structural concrete is recommended because these admixtures will reduce the mix water/cement ratio and resulting concrete permeability. Establishing a maximum water/cement ratio of 0.45 for structural concrete could also be considered to further increase sulfate resistance. Water-Soluble Sulfate Testing Report Prospect Properties Basketball Facility - Lot 5, Prospect Park East, P.U.D. 1601 Sharp Point Drive, Fort Collins, Colorado Soilogic # 22-1426 2 Foundation concrete should be designed in accordance with the provisions of the ACI Design Manual, Section 318, Chapter 4. We appreciate the opportunity to be of service to you on this project. If you have any questions concerning the enclosed information or if we can provide any further assistance, please do not hesitate to contact us. Very Truly Yours, Soilogic, Inc. Reviewed by: Darrel DiCarlo, P.E. Alec Kaljian, P.E. Senior Project Engineer Project Engineer 12/27/2022 12/27/2022