Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS AMENDMENT TRACT B - MA210028 - SUBMITTAL DOCUMENTS - ROUND 3 - ARCHITECTURAL DETAILSAVONDALE ROADBUILDING 'A' 6 UNIT BUILDING 'B' 6 UNIT UNIT 'L' 1,160 S.F. UNIT 'B' 1,035 S.F. TYPE 'B' UNITOX OXUNIT 'B2' 1,061 S.F. TYPE 'B' UNIT UNIT 'L' 1,160 S.F.1HR1HR 1HR 1HR 1HR 1HR1HR1HR1HR1HR1HR1HROX 1HROX1HR1HR1HRUNIT 'B' 1,035 S.F. UNIT 'B2' 1,061 S.F. TFG Design, LLCP.O. BoxLoveland CO 80539(970) 669.3737 SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER:DRAWN BY: saraZ:\Shared\Projects\111 Owen Consulting\111-2001FC Ridgewood Hills North\AutoCAD\111-2001FC Ridgewood Hills Tract B MA - 02\DWG\Exhibits\EX2.0 FLOOR PLANS.dwgFILE LOCATION:5/31/2023 9:19 AMPLOT DATE:PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. EX2.0 1 ADDRESSING PLANS 20221028 20230530 2ND SUBMITTAL - NO CLUBHOUSE 3RD SUBMITTAL 111-2001FC JULY 20, 2021 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com david@fronterra.design RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTYNORTH 0 SCALE:1" = 30' 15' 30'60'90' RIDGEWOOD HILLS BUILDINGS 'A' AND 'B' FLOOR PLANS 6-UNIT MAIN AND SECOND FLOOR PLANS SCALE: NTS AVONDALE ROAD ADDRESSES 7350 7374 Building A Units Building B Units A-101 B-101 A-102 B-102 A-103 B-103 A-104 B-104 A-201 B-201 A-202 B-202 A-101 / B-101 A-104 / B-104 A-102 / B-102 A-103 / B-103 A-201 / B-201 A-202 / B-202 NOTE: SUITE IDENTIFIERS ON THE EXTERIOR OF THE BUILDINGS SHALL BE A MINIMUM HEIGHT OF 4" WITH A MINIMUM 1/2" STROKE. SUITE IDENTIFIERS ON THE INTERIOR OF THE BUILDINGS SHALL BE A MINIMUM HEIGHT OF 2" WITH A MINIMUM 1/4" STROKE. ADDRESSES SHALL BE PROVIDED ON EACH SIDE OF THE BUILDING WHICH FRONTS A FIRE LANE AND EACH SIDE ADJACENT TO ANOTHER STREET. ADDRESSING SHALL MATCH THE ADDRESSING OF THE EXISTING RIDGEWOOD HILLS COMPLEX. EXTERIOR SIGNAGE INTERIOR SIGNAGE 3 OVERALL MAIN FLOOR PLAN SCALE: NTS OVERALL 2ND FLOOR PLAN T R I A N G L E D R I V E BUILDING 'C' 8 UNIT BUILDING 'D' 8 UNIT BUILDING 'E' 8 UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'D' 1,197 S.F. UNIT 'D' 1,197 S.F. UNIT 'D' 1,197 S.F. UNIT 'D' 1,197 S.F. TFG Design, LLCP.O. BoxLoveland CO 80539(970) 669.3737 SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER:DRAWN BY: saraZ:\Shared\Projects\111 Owen Consulting\111-2001FC Ridgewood Hills North\AutoCAD\111-2001FC Ridgewood Hills Tract B MA - 02\DWG\Exhibits\EX2.1 FLOOR PLANS.dwgFILE LOCATION:5/31/2023 9:19 AMPLOT DATE:PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. EX2.1 ADDRESSING PLANS 20221028 20230530 2ND SUBMITTAL - NO CLUBHOUSE 3RD SUBMITTAL 111-2001FC JULY 20, 2021 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com david@fronterra.design RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY0 SCALE:1" = 30' 15' 30'60'90' RIDGEWOOD HILLS BUILDINGS 'C' AND 'D' FLOOR PLANS 8-UNIT MAIN AND SECOND FLOOR PLANS C-101 / D-101 C-103 / D-103 C-102 / D-102 C-104 / D-104 C-201 / D-201 C-203 / D-203 C-202 / D-202 C-204 / D-204 TRIANGLE DRIVE ADDRESSES 419 413 Building C Units Building D Units C-101 D-101 C-102 D-102 C-103 D-103 C-104 D-104 C-201 D-201 C-202 D-202 C-203 D-203 C-204 D-204 NOTE: SUITE IDENTIFIERS ON THE EXTERIOR OF THE BUILDINGS SHALL BE A MINIMUM HEIGHT OF 4" WITH A MINIMUM 1/2" STROKE. SUITE IDENTIFIERS ON THE INTERIOR OF THE BUILDINGS SHALL BE A MINIMUM HEIGHT OF 2" WITH A MINIMUM 1/4" STROKE. ADDRESSES SHALL BE PROVIDED ON EACH SIDE OF THE BUILDING WHICH FRONTS A FIRE LANE AND EACH SIDE ADJACENT TO ANOTHER STREET. ADDRESSING SHALL MATCH THE ADDRESSING OF THE EXISTING RIDGEWOOD HILLS COMPLEX. EXTERIOR SIGNAGE INTERIOR SIGNAGE 2 NORTH 3 SCALE: NTS OVERALL 2ND FLOOR PLAN SCALE: NTS OVERALL MAIN FLOOR PLAN BUILDING 'E' 8 UNIT BUILDING 'F' 6 UNIT WOO DR O W DRIVE UNIT 'L' 1,160 S.F. UNIT 'B' 1,035 S.F. TYPE 'B' UNITOX OXUNIT 'B2' 1,061 S.F. TYPE 'B' UNIT UNIT 'L' 1,160 S.F.OXOXUNIT 'B' 1,035 S.F. UNIT 'B2' 1,061 S.F. UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'A' 1,279 S.F. TYPE 'B' UNIT UNIT 'D' 1,197 S.F. UNIT 'D' 1,197 S.F. UNIT 'D' 1,197 S.F. UNIT 'D' 1,197 S.F. TFG Design, LLCP.O. BoxLoveland CO 80539(970) 669.3737 SHEET OF SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER:DRAWN BY: saraZ:\Shared\Projects\111 Owen Consulting\111-2001FC Ridgewood Hills North\AutoCAD\111-2001FC Ridgewood Hills Tract B MA - 02\DWG\Exhibits\L2.2 FLOOR PLANS.dwgFILE LOCATION:5/31/2023 9:19 AMPLOT DATE:PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. EX2.2 ADDRESSING PLANS 20221028 20230530 2ND SUBMITTAL - NO CLUBHOUSE 3RD SUBMITTAL 111-2001FC JULY 20, 2021 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com david@fronterra.design RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY0 SCALE:1" = 30' 15' 30'60'90' RIDGEWOOD HILLS BUILDINGS 'E' AND 'F' FLOOR PLANS 8-UNIT AND 6-UNIT MAIN AND SECOND FLOOR PLANS TRIANGLE DRIVE ADDRESSES 401 339 Building E Units Building F Units E-101 F-101 E-102 F-102 E-103 F-103 E-104 F-104 E-201 F-201 E-202 F-202 E-203 E-204F-101 F-102 F-103 F-104 F-202 F-201 E-101 E-102 E-103 E-104 E-201 E-202 E-203 E-204 NOTE: SUITE IDENTIFIERS ON THE EXTERIOR OF THE BUILDINGS SHALL BE A MINIMUM HEIGHT OF 4" WITH A MINIMUM 1/2" STROKE. SUITE IDENTIFIERS ON THE INTERIOR OF THE BUILDINGS SHALL BE A MINIMUM HEIGHT OF 2" WITH A MINIMUM 1/4" STROKE. ADDRESSES SHALL BE PROVIDED ON EACH SIDE OF THE BUILDING WHICH FRONTS A FIRE LANE AND EACH SIDE ADJACENT TO ANOTHER STREET. ADDRESSING SHALL MATCH THE ADDRESSING OF THE EXISTING RIDGEWOOD HILLS COMPLEX. EXTERIOR SIGNAGE INTERIOR SIGNAGE 3 NORTH 3 SCALE: NTS BUILDING 'E' - MAIN FLOOR PLAN SCALE: NTS BUILDING 'E' - 2ND FLOOR PLAN SCALE: NTS BUILDING 'F' - MAIN FLOOR PLAN SCALE: NTS BUILDING 'F' - 2ND FLOOR PLAN