HomeMy WebLinkAboutRIDGEWOOD HILLS AMENDMENT TRACT B - MA210028 - SUBMITTAL DOCUMENTS - ROUND 3 - LANDSCAPE PLAN (2)SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI
HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV 5` RADIUS 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV 8` RADIUS 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV 10` RADIUS 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV 12` RADIUS 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV 15` RADIUS 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV 17` RADIUS 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER PROS-06-PRS30-CV ADJUSTABLE ARC 30
TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH
FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL.
HUNTER MP CORNER PROS-06-PRS40-CV 40
TURF ROTATOR, 6" (15.24CM) POP-UP WITH FACTORY
INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40
PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY.
T=TURQUOISE ADJ ARC 45-105.
HUNTER MP1000 PROS-06-PRS40-CV 40
TURF ROTATOR, 6" (15.24 CM) POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR
NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210,
L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC.
HUNTER MP2000 PROS-06-PRS40-CV 40
TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY
INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40
PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY.
K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270,
R=RED 360 ARC.
HUNTER MP3000 PROS-06-PRS40-CV 40
TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY
INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40
PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY.
B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270,
A=GRAY 360 ARC.
HUNTER MP3500 PROS-06-PRS40-CV 40
TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED
CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP
ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN
ADJUSTABLE ARC, 90-210.
HUNTER MP800SR PROS-06-PRS40-CV 40
TURF ROTATOR, 6.0" POP-UP WITH CHECK VALVE,
PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR
NOZZLE ON PRS40 BODY. ADJ=ORANGE AND GRAY ( ARC
90-210), 360=LIME GREEN AND GRAY (ARC 360)
SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS
HUNTER I-20-04-SS 45 2.5 35'
TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE.
HUNTER I-20-04-SS 45 4 40'
TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE.
HUNTER I-20-04-SS 45 6 43'
TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE.
STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD
NOZZLE.
T
M L O
K G R
B Y A
IRRIGATION SCHEDULE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
RAIN BIRD XCZ-PRB-100-COM
MEDIUM PLUS FLOW DRIP CONTROL KIT FOR
COMMERCIAL APPLICATIONS. FLOW RANGE 3GPM TO
20GPM.
RAIN BIRD MDCFCAP
DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING
COUPLER.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER ICV-G: 1" PLASTIC ELECTRIC REMOTE CONTROL
VALVES (SIZE AS DESIGNATED).
QUICK COUPLER VALVE ASSEMBLY
HUNTER HQ-5RC: VALVE WITH YELLOW RUBBER COVER,
RED BRASS AND STAINLESS STEEL, WITH 1" NPT INLET,
1-PIECE BODY.
MATCO-NORCA 514TX
1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID
WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE
PIPE.
MASTER VALVE ASSEMBLY
BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS
MASTER VALVE THAT PROVIDES DIRTY WATER
PROTECTION. SIZE TO MATCH POC
WILKINS 375B
REDUCED PRESSURE BACKFLOW PREVENTER WITH BLOW
OUT/FLUSH FITTING. REINFORCED NYLON HOUSING AND
CAST BRONZE BALL VALVES. SIZED TO MATCH TAP &
METER (RE: POC NOTE).
PEDESTAL MOUNT
HUNTER PED-SS-A2C-75D-SS & A2C-WIFI:75-STATION
DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL
PEDESTAL. INCLUDES A2C WI-FI NETWORKING MODULE
FOR ACC2 CONTROLLER.
PEDESTAL MOUNT
HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER
CONTROLLER IN AN OUTDOOR STAINLESS STEEL
PEDESTAL. INSTALL WIRELESS RAIN SENSOR AND SOLAR
SYNC
PEDESTAL MOUNT 2-WIRE CONTROLLER
HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER
CONTROLLER IN AN OUTDOOR STAINLESS STEEL
PEDESTAL. INSTALL WIRELESS RAIN SENSOR AND SOLAR
SYNC
CREATIVE SENSOR TECHNOLOGY FSI-T
1-INCH PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS,
CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER
ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL
OUTPUT. FLOW RANGE: .86-52 GPM.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL
TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED
ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE.
PLANTING BED DRIP IRRIGATION LATERAL LINE:3/4-INCH
BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO
SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART.
NATIVE PLANTING DRIP IRRIGATION LATERAL LINE: 3/4-INCH \
BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO
TREE RINGS, NETAFIM INLINE DRIP TUBING MODEL
TLCV6-18, AND SINGLE OUTLET EMITTERS FOR SHRUBS
PER ADJACENT EMITTER CHART
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
1.25-INCH UNLESS OTHERWISE NOTED.
PIPE SLEEVE: PVC CLASS 200 SDR 21
TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. REFER TO
SPECIFICATIONS.
A
A
A
INSTALLATION GENERAL NOTES
1. DESIGN ASSUMES A REQUIRED MINIMUM DYNAMIC PRESSURE FOR THE
IRRIGATION SYSTEM (NOT OBTAINED) OF 73 PSI, AT A MAXIMUM FLOW OF 18 GPM
AT THE 1-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON
SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S
REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED
ABOVE.
1.1. IRRIGATION IS CONNECTED DOWNSTREAM OF THE 1-INCH DOMESTIC
METER FEEDING THE CLUBHOUSE AS INDICATED. IRRIGATION IS DESIGNED
TO UTILIZE ONLY 18 GPM.
1.2. IF PRESSURE IS TESTED LOWER THAN STATED ABOVE, BOOSTER PUMP
MAY BE REQUIRED.
2. ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES,
WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN
FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS.
3. CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED
TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED
CONTROLLER MAP.
4. CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND
INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO
CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR
TO CONSTRUCTION.
4.1. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED
ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER
ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS,
QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE
ADJUSTMENT KEYS.
4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS
PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT,
TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE
RCV DIAPHRAGM, ETC.
5. COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION ("811-CALL BEFORE YOU DIG") .
6. IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS
AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S
REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED
WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN
THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS.
7. ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.)
SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN
THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING
AREAS FOR CLARITY.
8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING
MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE.
COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS
WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE
MATERIAL CANNOT BE RELOCATED, ADDITIONAL SPRINKLERS MAY BE
REQUIRED.
9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS.
10. CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED
AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE
CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL
CONTACT IRRIGATION DESIGNER FOR APPROVAL.
11. CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR
TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING
SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS
ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE
CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES.
ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE
SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE
IRRIGATION CONTRACTOR.
12. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL
ELECTRIC UTILITY CODES.
13. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A
SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED
SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED
SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT
PIPE SIZE NOTED IN THE LEGEND.
13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH
MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG.
STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS.
14. TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES
TO BE ROUTED WITH MAINLINE.
14.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED
ON PLANS
15. TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL
ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN
NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM.
16. VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.
17. NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE
SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT
INTENDED TO OPERATE BEYOND ESTABLISHMENT.
18. NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE,
VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING
FOUNDATION.
SYMBOL DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE DOMESTIC WATER TAP AND METER AT THE
APPROXIMATE LOCATION SHOWN (REFER TO CIVIL PLANS FOR
EXACT LOCATION). INSTALL BACKFLOW PREVENTION UNIT,
MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED.
VERIFY EXACT LOCATION OF POC WITH OWNER`S
REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO
CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER
NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW
SHALL BE TESTED UPON INSTALLATION AND ANNUALLY
THEREAFTER.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW BEHIND PLANT
MATERIAL WHERE APPLICABLE. FINAL LOCATION TO BE APPROVED
BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE INSTALLED
PER NATIONAL ELECTRIC CODE.
IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL
IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY
IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE
SLEEVED.
MAINLINE, SPRINKLER LATERAL, AND/OR DRIP LATERAL SHOWN
SLEEVED TOGETHER IS FOR CLARITY ONLY. CONTRACTOR SHALL
INSTALL MAINLINE, CONTROL WIRES, AND LATERAL LINES IN
SEPARATE SLEEVES.
1
2
3
4
REFERENCE NOTES SCHEDULE
EMITTER SCHEDULE
PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL
FLOW
GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH
PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH
1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH
5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH
TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH
TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A
NOTES:
1. MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB
BEDS.
2. NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS.
SHEET OF
IR1.0
41
NORTH
TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
PROJECT NUMBER:
DATE:
PHASE:
www.tfgdesign.com
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT.
IRRIGATION LEGEND
AND NOTES
OCTOBER 28, 2022 2ND SUBMITTAL
111-2001FC
DEC 29, 2020
MINOR
AMENDMENT
Bill TimmM. Timm Development
233 Carillo Street
Santa Barbara, California 93101
805.963.0358
btimm@mtimm.com
design@tfgdesign.com
RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY0 15 30 60
MAY 20, 2023 3RD SUBMITTAL
T
R
I
A
N
G
L
E
D
R
I
V
E
AVONDALE ROADPOC
TAP AND METER SIZE: 1-INCH
AVAILABLE FLOW: 18 GPM
REQUIRED PRESSURE: 73 PSI
CONTROLLER
120 VAC POWER REQUIRED
1
ADOMESTIC
METER
4
A6
181"
A7
181"
A9
161"A11
181"
A12
171"
A13
181"
A14
131"
A15
111"
A16
171"
A17
181"
A19
181"
A20
151"
A21
51"
A22
181"
A25
181"
A27
171"
A28
181"
A29
181"
A30
181"
A31
181"
A32
181"
A34
181"A35
181"
A36
171"A37
16.31"
A39
151"
A40
141"
A41
131"
A43
181"
A45
181"
A46
181"
A47
181"
A48
171"
A51
Drip1"
A52
Drip1"
A53
Drip1"
A54
Drip1"
A55
Drip1"
A56
Drip1"
A58
16N1"
A59
18N1"
A64
18N1"
A65
16N1"
A66
16N1"
2
A4
51"
A8
91"
A10
181"
A18
181"
A23
91"
A24
171"
A26
181"
A33
181"
A38
171"
A42
15.81"
A44
161"
A63
141"
A62
181"
A1
171"
A2
181"
A3
151"
A50
Drip1"
A69
18N1"
A70
16N1"
A60
5N1"
A57
18N1"
A61
18N1"
A49
Drip1"
A67
18N1"
3
A5
181"
SHEET OF
IR1.1
42
NORTH
TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
PROJECT NUMBER:
DATE:
PHASE:
www.tfgdesign.com
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT.
IRRIGATION PLAN
111-2001FC
DEC 29, 2020
MINOR
AMENDMENT
Bill TimmM. Timm Development
233 Carillo Street
Santa Barbara, California 93101
805.963.0358
btimm@mtimm.com
design@tfgdesign.com
RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY0 15 30 60
OCTOBER 28, 2022 2ND SUBMITTAL
MAY 20, 2023 3RD SUBMITTAL
SHEET OF
IR2.1
43
TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
PROJECT NUMBER:
DATE:
PHASE:
www.tfgdesign.com
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT.
IRRIGATION DETAILS
111-2001FC
DEC 29, 2020
MINOR
AMENDMENT
Bill TimmM. Timm Development
233 Carillo Street
Santa Barbara, California 93101
805.963.0358
btimm@mtimm.com
design@tfgdesign.com
RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY1 1/2" = 1'-0"
ISOLATION GATE VALVE3 328406.33-01
1 1/2" = 1'-0"
REMOTE CONTROL TURF VALVE W/DECODER
328406.13-065 3" = 1'-0"
6-INCH POP-UP SPRAY6 328403.13-02
1 1/2" = 1'-0"
MASTER VALVE/FLOW SENSOR ON DECODER
328406.23-112
3" = 1'-0"
GEAR-DRIVEN ROTOR ASSEMBLY7 328403.16-01
3" = 1'-0"
DRIP EMITTER AT 1/4" TUBING
SINGLE-OUTLET EMITTER.
1/2" POLY DRIP TUBING.
EMITTER.
TIE-DOWN STAKE AT
TOP OF MULCH ELEVATION.
1/4" DISTRIBUTION TUBING.
1/4" TUBING STAKE.
DIFFUSER BUG CAP.
FX-IR-FX-EMIT-039 N.T.S.
TREE RING IN NATIVE SEED APPLICATIONS
NETAFIM TECHLINE CV INLINE DRIP TUBING:
MODEL TLCV6-18
TIE DOWN STAKE, (QTY. AS REQUIRED)
TREE TRUNK
NOTE:
1. CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN NATIVE AREAS 2-3" BELOW GRADE IF MULCH IS NOT
PRESENT. IF MULCH IS PRESENT, LAY TUBING ON FINISHED GRADE BELOW MULCH.
2. DIAMETER OF DRIPLINE RINGS ARE DEPENDENT ON TREE CANOPY SIZE AND SHALL BE ADJUSTED IN THE
FIELD PER CONTRACTOR. SUGGESTED PLACEMENT OF 2' DIAMETER AND 3' DIAMETER AROUND TREE.
3. SHRUBS IN NATIVE SHALL UTILIZE SINGLE OUTLET EMITTERS.
TEE FITTING INSERT AND PVC THREADED
1-INCH CLASS 200 PVC SDR 21 PIPE
INSERT ELBOW FITTINGS WITH STAINLESS
STEEL SCREW CLAMPS
FLUSH CAP (1 of 2)
11 328413.56-12
1" = 1'-0"
RP BACKFLOW W/ ENCLOSURE W/DRAIN
COVER SIZE + 6"
328409.46-081
1 1/2" = 1'-0"
QUICK COUPLING VALVE IN BOX4 328406.43-02
1 1/2" = 1'-0"
DRIP FLUSH CAP ASSEMBLY
6" DIAMETER CARSON VALVE BOX.
COIL 18" TO 24" OF DRIP TUBING IN THE
BOX.
REMOVABLE FLUSH CAP PER
LEGEND.
ABOVE GRADE DRIP
TUBING.
4" THICK LAYER OF WASHED
GRAVEL. THE BOX SHALL REST
UPON THE ROCK BED. DO NOT
EXTEND GRAVEL INTO BOX.
1. LOCATE FLUSH CAP ASSEMBLY AT THE END OF EACH DRIP LINE.
2. ENSURE THAT THE COILED DRIP TUBING IS OF SUFFICIENT LENGTH TO
COMPLETELY EXTEND OUT OF THE VALVE BOX WHEN FLUSHING.
328413.49-06.101 1/2" = 1'-0"
1" DRIP VALVE/FILTER/REGULATOR W/DECODER
SxT TEE W/ 2" NIPPLE AT
MAINLINE.
SCH. 80 RISER.
PRESSURE REGULATOR AS
SPECIFIED.
PVC TRUE UNION BALL
VALVE.
CARSON 1419-T PLASTIC VALVE
BOX. STAMP STATION NO.
FILTER AS SPECIFIED.
RCV AS SPECIFIED.DEPTH PER SPECS3" MIN.TWO-WIRE DECODER
PER MANUFACTURER
TWO-WIRE CONTROL
CABLE PER
MANUFACTURER
328413.76-248
OCTOBER 28, 2022 2ND SUBMITTAL
MAY 20, 2023 3RD SUBMITTAL
SHEET OF
IR2.2
44
TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
PROJECT NUMBER:
DATE:
PHASE:
www.tfgdesign.com
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT.
IRRIGATION DETAILS
111-2001FC
DEC 29, 2020
MINOR
AMENDMENT
Bill TimmM. Timm Development
233 Carillo Street
Santa Barbara, California 93101
805.963.0358
btimm@mtimm.com
design@tfgdesign.com
RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTYSLEEVE AT ROAD
1 1/2" = 1'-0"328409.76-2015TYPICAL SLEEVE
N.T.S.
24" min.
12" min
4"-6" MIN.
4"-6" MIN.
36"
14 328409.76-21
N.T.S
TYPICAL TRENCH DETAIL
NOTES:
1. SLEEVE ALL PIPE AND WIRE SEPARATELY.
2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. "SNAKE"
UNSLEEVED PLASTIC PIPE IN TRENCH. PROVIDE A MIN. OF 2" CLEARANCE TO
SIDE OF TRENCH AND BETWEEN PIPES.
3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE
REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20"
LOOP AT ALL CHANGES OF DIRECTION OVER 30 DEGREES.
328409.76-1616
N.T.S.
TYPICAL DECODER GROUND AT VALVE
GROUND WIRE OF DECODER CONNECTED
TO GROUND ROD USING BRASS CLAMP
2-WIRE COMMUNICATION PATH
BLUE WIRES TO 2-WIRE COMMUNICATION PATH
FINISH GRADE
SURGE ARRESTOR: PER CONTROLLER
MANUFACTURER
DBY CONNECTORS
WHITE WIRES TO SOLENOID
VALVE BOX
DECODER: PER CONTROLLER MANUFACTURE
CHRISTY ID TAG: MARK WITH STATION NO.
EXPANSION COILS
BRASS CLAMP
SOLENOID
VALVE BOX EXTENSION (LENGTH AS
REQUIRED)
3/4" WASHED GRAVEL
NOTES: WIRES MUST EXTEND 12" ABOVE VALVE BOX FOR SERVICE.
5/8" DIA. X 8'-0" COPPER CLAD GROUND ROD,
DRIVEN INTO GROUND WITH TOP OF ROD
MINIMUM OF 6" BELOW GRADE.SEE
MANUFACTURER'S SPECIFICATIONS FOR
COMPLETE GROUNDING INFORMATION.
12 1 1/2" = 1'-0"
SURGE DECODER ON TWO-WIRE PATH
FINISH GRADE OR
TOP OF MULCH
GROUNDING ROD:
10 OHMS OR LESS
GREEN/YELLOW WIRE FROM
SURGE DECODER TO
GROUNDING ROD BRASS
CLAMPS (1 OF 2)
DB SERIES WIRE
CONNECTOR (1 OF 2)
LINE SURGE PROTECTOR,
PER CONTROLLER
MANUFACTURER
TWO-WIRE CABLE
3-INCH MINIMUM DEPTH
OF 3/4-INCH WASHED
GRAVEL
BRICK (1 OF 2)
CARSON 910-T
VALVE BOX.
13 328409.16-25
N.T.S.
PEDESTAL MOUNT CONTROLLER17 32 8409.16-03
OCTOBER 28, 2022 2ND SUBMITTAL
MAY 20, 2023 3RD SUBMITTAL