Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS AMENDMENT TRACT B - MA210028 - SUBMITTAL DOCUMENTS - ROUND 3 - LANDSCAPE PLAN (2)SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI HUNTER PROS-06-PRS30-CV 5` STRIP SPRAY 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV 5` RADIUS 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV 8` RADIUS 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV 10` RADIUS 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV 12` RADIUS 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV 15` RADIUS 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV 17` RADIUS 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER PROS-06-PRS30-CV ADJUSTABLE ARC 30 TURF SPRAY, 30 PSI REGULATED 6.0" POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED WIPER SEAL WITH UV RESISTANT MATERIAL. HUNTER MP CORNER PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. T=TURQUOISE ADJ ARC 45-105. HUNTER MP1000 PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24 CM) POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. M=MAROON ADJ ARC 90 TO 210, L=LIGHT BLUE 210 TO 270 ARC, O=OLIVE 360 ARC. HUNTER MP2000 PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270, R=RED 360 ARC. HUNTER MP3000 PROS-06-PRS40-CV 40 TURF ROTATOR, 6" (15.24 CM) POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270, A=GRAY 360 ARC. HUNTER MP3500 PROS-06-PRS40-CV 40 TURF ROTATOR, 6.0" POP-UP WITH FACTORY INSTALLED CHECK VALVE, PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40 BODY. LB=LIGHT BROWN ADJUSTABLE ARC, 90-210. HUNTER MP800SR PROS-06-PRS40-CV 40 TURF ROTATOR, 6.0" POP-UP WITH CHECK VALVE, PRESSURE REGULATED TO 40 PSI (2.76 BAR), MP ROTATOR NOZZLE ON PRS40 BODY. ADJ=ORANGE AND GRAY ( ARC 90-210), 360=LIME GREEN AND GRAY (ARC 360) SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS HUNTER I-20-04-SS 45 2.5 35' TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. HUNTER I-20-04-SS 45 4 40' TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. HUNTER I-20-04-SS 45 6 43' TURF ROTOR, 4.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE. T M L O K G R B Y A IRRIGATION SCHEDULE SYMBOL MANUFACTURER/MODEL/DESCRIPTION RAIN BIRD XCZ-PRB-100-COM MEDIUM PLUS FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. FLOW RANGE 3GPM TO 20GPM. RAIN BIRD MDCFCAP DRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTING COUPLER. SYMBOL MANUFACTURER/MODEL/DESCRIPTION REMOTE CONTROL VALVE ASSEMBLY HUNTER ICV-G: 1" PLASTIC ELECTRIC REMOTE CONTROL VALVES (SIZE AS DESIGNATED). QUICK COUPLER VALVE ASSEMBLY HUNTER HQ-5RC: VALVE WITH YELLOW RUBBER COVER, RED BRASS AND STAINLESS STEEL, WITH 1" NPT INLET, 1-PIECE BODY. MATCO-NORCA 514TX 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE. MASTER VALVE ASSEMBLY BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER VALVE THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO MATCH POC WILKINS 375B REDUCED PRESSURE BACKFLOW PREVENTER WITH BLOW OUT/FLUSH FITTING. REINFORCED NYLON HOUSING AND CAST BRONZE BALL VALVES. SIZED TO MATCH TAP & METER (RE: POC NOTE). PEDESTAL MOUNT HUNTER PED-SS-A2C-75D-SS & A2C-WIFI:75-STATION DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL. INCLUDES A2C WI-FI NETWORKING MODULE FOR ACC2 CONTROLLER. PEDESTAL MOUNT HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL. INSTALL WIRELESS RAIN SENSOR AND SOLAR SYNC PEDESTAL MOUNT 2-WIRE CONTROLLER HUNTER PED-SS-A2C-75D-SS:75-STATION DECODER CONTROLLER IN AN OUTDOOR STAINLESS STEEL PEDESTAL. INSTALL WIRELESS RAIN SENSOR AND SOLAR SYNC CREATIVE SENSOR TECHNOLOGY FSI-T 1-INCH PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT. FLOW RANGE: .86-52 GPM. IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21 PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 1" IN SIZE. PLANTING BED DRIP IRRIGATION LATERAL LINE:3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART. NATIVE PLANTING DRIP IRRIGATION LATERAL LINE: 3/4-INCH \ BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO TREE RINGS, NETAFIM INLINE DRIP TUBING MODEL TLCV6-18, AND SINGLE OUTLET EMITTERS FOR SHRUBS PER ADJACENT EMITTER CHART IRRIGATION MAINLINE: PVC CLASS 200 SDR 21 1.25-INCH UNLESS OTHERWISE NOTED. PIPE SLEEVE: PVC CLASS 200 SDR 21 TYPICAL PIPE SLEEVE FOR IRRIGATION PIPE. REFER TO SPECIFICATIONS. A A A INSTALLATION GENERAL NOTES 1. DESIGN ASSUMES A REQUIRED MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION SYSTEM (NOT OBTAINED) OF 73 PSI, AT A MAXIMUM FLOW OF 18 GPM AT THE 1-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE. 1.1. IRRIGATION IS CONNECTED DOWNSTREAM OF THE 1-INCH DOMESTIC METER FEEDING THE CLUBHOUSE AS INDICATED. IRRIGATION IS DESIGNED TO UTILIZE ONLY 18 GPM. 1.2. IF PRESSURE IS TESTED LOWER THAN STATED ABOVE, BOOSTER PUMP MAY BE REQUIRED. 2. ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS. 3. CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP. 4. CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION. 4.1. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS. 4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM, ETC. 5. COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION ("811-CALL BEFORE YOU DIG") . 6. IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS. 7. ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY. 8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED, ADDITIONAL SPRINKLERS MAY BE REQUIRED. 9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS. 10. CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION DESIGNER FOR APPROVAL. 11. CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR. 12. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL ELECTRIC UTILITY CODES. 13. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND. 13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS. 14. TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE WIRES TO BE ROUTED WITH MAINLINE. 14.1.TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED ON PLANS 15. TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM. 16. VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM. 17. NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND ESTABLISHMENT. 18. NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION. SYMBOL DESCRIPTION THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE DOWNSTREAM OF THE DOMESTIC WATER TAP AND METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION UNIT, MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW SHALL BE TESTED UPON INSTALLATION AND ANNUALLY THEREAFTER. PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER`S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE, AND SCREENED FROM VIEW BEHIND PLANT MATERIAL WHERE APPLICABLE. FINAL LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE. CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE. IRRIGATION SHOWN IN HARDSCAPE FOR CLARITY ONLY. ALL IRRIGATION SHALL BE INSTALLED IN LANDSCAPED AREA. ANY IRRIGATION TO BE INSTALLED UNDER HARDSCAPE SHALL BE SLEEVED. MAINLINE, SPRINKLER LATERAL, AND/OR DRIP LATERAL SHOWN SLEEVED TOGETHER IS FOR CLARITY ONLY. CONTRACTOR SHALL INSTALL MAINLINE, CONTROL WIRES, AND LATERAL LINES IN SEPARATE SLEEVES. 1 2 3 4 REFERENCE NOTES SCHEDULE EMITTER SCHEDULE PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH 1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH 5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A NOTES: 1. MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB BEDS. 2. NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS. SHEET OF IR1.0 41 NORTH TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. IRRIGATION LEGEND AND NOTES OCTOBER 28, 2022 2ND SUBMITTAL 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY0 15 30 60 MAY 20, 2023 3RD SUBMITTAL T R I A N G L E D R I V E AVONDALE ROADPOC TAP AND METER SIZE: 1-INCH AVAILABLE FLOW: 18 GPM REQUIRED PRESSURE: 73 PSI CONTROLLER 120 VAC POWER REQUIRED 1 ADOMESTIC METER 4 A6 181" A7 181" A9 161"A11 181" A12 171" A13 181" A14 131" A15 111" A16 171" A17 181" A19 181" A20 151" A21 51" A22 181" A25 181" A27 171" A28 181" A29 181" A30 181" A31 181" A32 181" A34 181"A35 181" A36 171"A37 16.31" A39 151" A40 141" A41 131" A43 181" A45 181" A46 181" A47 181" A48 171" A51 Drip1" A52 Drip1" A53 Drip1" A54 Drip1" A55 Drip1" A56 Drip1" A58 16N1" A59 18N1" A64 18N1" A65 16N1" A66 16N1" 2 A4 51" A8 91" A10 181" A18 181" A23 91" A24 171" A26 181" A33 181" A38 171" A42 15.81" A44 161" A63 141" A62 181" A1 171" A2 181" A3 151" A50 Drip1" A69 18N1" A70 16N1" A60 5N1" A57 18N1" A61 18N1" A49 Drip1" A67 18N1" 3 A5 181" SHEET OF IR1.1 42 NORTH TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. IRRIGATION PLAN 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY0 15 30 60 OCTOBER 28, 2022 2ND SUBMITTAL MAY 20, 2023 3RD SUBMITTAL SHEET OF IR2.1 43 TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. IRRIGATION DETAILS 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTY1 1/2" = 1'-0" ISOLATION GATE VALVE3 328406.33-01 1 1/2" = 1'-0" REMOTE CONTROL TURF VALVE W/DECODER 328406.13-065 3" = 1'-0" 6-INCH POP-UP SPRAY6 328403.13-02 1 1/2" = 1'-0" MASTER VALVE/FLOW SENSOR ON DECODER 328406.23-112 3" = 1'-0" GEAR-DRIVEN ROTOR ASSEMBLY7 328403.16-01 3" = 1'-0" DRIP EMITTER AT 1/4" TUBING SINGLE-OUTLET EMITTER. 1/2" POLY DRIP TUBING. EMITTER. TIE-DOWN STAKE AT TOP OF MULCH ELEVATION. 1/4" DISTRIBUTION TUBING. 1/4" TUBING STAKE. DIFFUSER BUG CAP. FX-IR-FX-EMIT-039 N.T.S. TREE RING IN NATIVE SEED APPLICATIONS NETAFIM TECHLINE CV INLINE DRIP TUBING: MODEL TLCV6-18 TIE DOWN STAKE, (QTY. AS REQUIRED) TREE TRUNK NOTE: 1. CONTRACTOR SHALL INSTALL ALL DRIP TUBING IN NATIVE AREAS 2-3" BELOW GRADE IF MULCH IS NOT PRESENT. IF MULCH IS PRESENT, LAY TUBING ON FINISHED GRADE BELOW MULCH. 2. DIAMETER OF DRIPLINE RINGS ARE DEPENDENT ON TREE CANOPY SIZE AND SHALL BE ADJUSTED IN THE FIELD PER CONTRACTOR. SUGGESTED PLACEMENT OF 2' DIAMETER AND 3' DIAMETER AROUND TREE. 3. SHRUBS IN NATIVE SHALL UTILIZE SINGLE OUTLET EMITTERS. TEE FITTING INSERT AND PVC THREADED 1-INCH CLASS 200 PVC SDR 21 PIPE INSERT ELBOW FITTINGS WITH STAINLESS STEEL SCREW CLAMPS FLUSH CAP (1 of 2) 11 328413.56-12 1" = 1'-0" RP BACKFLOW W/ ENCLOSURE W/DRAIN COVER SIZE + 6" 328409.46-081 1 1/2" = 1'-0" QUICK COUPLING VALVE IN BOX4 328406.43-02 1 1/2" = 1'-0" DRIP FLUSH CAP ASSEMBLY 6" DIAMETER CARSON VALVE BOX. COIL 18" TO 24" OF DRIP TUBING IN THE BOX. REMOVABLE FLUSH CAP PER LEGEND. ABOVE GRADE DRIP TUBING. 4" THICK LAYER OF WASHED GRAVEL. THE BOX SHALL REST UPON THE ROCK BED. DO NOT EXTEND GRAVEL INTO BOX. 1. LOCATE FLUSH CAP ASSEMBLY AT THE END OF EACH DRIP LINE. 2. ENSURE THAT THE COILED DRIP TUBING IS OF SUFFICIENT LENGTH TO COMPLETELY EXTEND OUT OF THE VALVE BOX WHEN FLUSHING. 328413.49-06.101 1/2" = 1'-0" 1" DRIP VALVE/FILTER/REGULATOR W/DECODER SxT TEE W/ 2" NIPPLE AT MAINLINE. SCH. 80 RISER. PRESSURE REGULATOR AS SPECIFIED. PVC TRUE UNION BALL VALVE. CARSON 1419-T PLASTIC VALVE BOX. STAMP STATION NO. FILTER AS SPECIFIED. RCV AS SPECIFIED.DEPTH PER SPECS3" MIN.TWO-WIRE DECODER PER MANUFACTURER TWO-WIRE CONTROL CABLE PER MANUFACTURER 328413.76-248 OCTOBER 28, 2022 2ND SUBMITTAL MAY 20, 2023 3RD SUBMITTAL SHEET OF IR2.2 44 TFG Design, LLCP.O. Box 178Loveland CO 80539(970) 669.3737 SHEET NUMBER: SHEET TITLE: REVISIONS: PROJECT INFORMATION: OWNER: PROJECT NUMBER: DATE: PHASE: www.tfgdesign.com THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS ANDSHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THEFRONTERRA GROUP AND SHALL NOT BE REPRODUCED,PUBLISHED OR USED IN ANY WAY WITHOUT THEPERMISSION OF THE LANDSCAPE ARCHITECT. IRRIGATION DETAILS 111-2001FC DEC 29, 2020 MINOR AMENDMENT Bill TimmM. Timm Development 233 Carillo Street Santa Barbara, California 93101 805.963.0358 btimm@mtimm.com design@tfgdesign.com RIDGEWOOD HILLSFIFTH FILINGMINOR AMENDMENTAVONDALE RD & TRIANGLE DRFORT COLLINS, COLORADO LARIMER COUNTY COUNTYSLEEVE AT ROAD 1 1/2" = 1'-0"328409.76-2015TYPICAL SLEEVE N.T.S. 24" min. 12" min 4"-6" MIN. 4"-6" MIN. 36" 14 328409.76-21 N.T.S TYPICAL TRENCH DETAIL NOTES: 1. SLEEVE ALL PIPE AND WIRE SEPARATELY. 2. ALL PIPE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. "SNAKE" UNSLEEVED PLASTIC PIPE IN TRENCH. PROVIDE A MIN. OF 2" CLEARANCE TO SIDE OF TRENCH AND BETWEEN PIPES. 3. ALL 120-V WIRING SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL CODE REQUIREMENTS. TAPE AND BUNDLE 24-V WIRE EVERY 10' AND PROVIDE LOOSE 20" LOOP AT ALL CHANGES OF DIRECTION OVER 30 DEGREES. 328409.76-1616 N.T.S. TYPICAL DECODER GROUND AT VALVE GROUND WIRE OF DECODER CONNECTED TO GROUND ROD USING BRASS CLAMP 2-WIRE COMMUNICATION PATH BLUE WIRES TO 2-WIRE COMMUNICATION PATH FINISH GRADE SURGE ARRESTOR: PER CONTROLLER MANUFACTURER DBY CONNECTORS WHITE WIRES TO SOLENOID VALVE BOX DECODER: PER CONTROLLER MANUFACTURE CHRISTY ID TAG: MARK WITH STATION NO. EXPANSION COILS BRASS CLAMP SOLENOID VALVE BOX EXTENSION (LENGTH AS REQUIRED) 3/4" WASHED GRAVEL NOTES: WIRES MUST EXTEND 12" ABOVE VALVE BOX FOR SERVICE. 5/8" DIA. X 8'-0" COPPER CLAD GROUND ROD, DRIVEN INTO GROUND WITH TOP OF ROD MINIMUM OF 6" BELOW GRADE.SEE MANUFACTURER'S SPECIFICATIONS FOR COMPLETE GROUNDING INFORMATION. 12 1 1/2" = 1'-0" SURGE DECODER ON TWO-WIRE PATH FINISH GRADE OR TOP OF MULCH GROUNDING ROD: 10 OHMS OR LESS GREEN/YELLOW WIRE FROM SURGE DECODER TO GROUNDING ROD BRASS CLAMPS (1 OF 2) DB SERIES WIRE CONNECTOR (1 OF 2) LINE SURGE PROTECTOR, PER CONTROLLER MANUFACTURER TWO-WIRE CABLE 3-INCH MINIMUM DEPTH OF 3/4-INCH WASHED GRAVEL BRICK (1 OF 2) CARSON 910-T VALVE BOX. 13 328409.16-25 N.T.S. PEDESTAL MOUNT CONTROLLER17 32 8409.16-03 OCTOBER 28, 2022 2ND SUBMITTAL MAY 20, 2023 3RD SUBMITTAL