Loading...
HomeMy WebLinkAboutKUM & GO #0951 - FDP230009 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (4)PROJECTLOCATIONE SHEET NUMBER:CPM: SDM: RDM:03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT 1459 Grand AvenueDes Moines, Iowa50309P: 515-226-0128F: 515-223-9873DATE:TCDGBSCALL 811 SEVENTY-TWO HOURS PRIOR TODIGGING, GRADING OR EXCAVATING FOR THEMARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013 Know what'sbelow.before you dig.CallRwww.olsson.comTEL 303.237.2072 1525 Raleigh St. Suite 400 Denver, CO 80204 DATE REVISION DESCRIPTION OF 40VICINITY MAPNOT TO SCALEBASIS OF BEARINGS:ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, ASMONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND ACONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56"EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRALZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGSCONTAINED HEREIN RELATIVE THERETO.FLOOD ZONE:1. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YEAR SPRINGCREEK FLOODPLAIN.2. DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS ANDPAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTIONACTIVITY (CURB & GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKINGLOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRINGCREEK FLOODPLAIN LIMITS AS DELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIESWITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORTCOLLINS MUNICIPAL CODE.PROJECT TEAM:AGENCY CONTACTS:OWNER/DEVELOPER/APPLICANT:KUM & GO L.L.C.1459 GRAND AVENUEDES MOINES, IA 50309CONTACT: DAN GARNEAUPH: (515) 226.0128E: DAN.GARNEAU@KUMANDGO.COMENGINEER:OLSSON, INC.1880 FALL RIVER DRIVE, SUITE 200LOVELAND, CO 80538CONTACT: ERICA MORTONPH: (970) 635.3744E: EMORTON@OLSSON.COMLANDSCAPE ARCHITECT:GEOTECHNICAL ENGINEER:OLSSON, INC.5180 SMITH ROAD, UNIT FDENVER, CO 80216CONTACT: MICHAEL FLANAGANPH:(303) 237.2072E: MFLANAGAN@OLSSON.COMSURVEYOR:OLSSON, INC.5180 SMITH ROAD, UNIT FDENVER, CO 80216CONTACT: NIC SCHRADERPH: (303) 374.3114E: NSCHRADER@OLSSON.COMSANITARY SEWER:TELEPHONE:GAS:XCEL ENERGY1901 E. HORSETOOTH ROADFT. COLLINS, COCONTACT: PAT KREAGERE: PAT.KREAGER@XCELENERGY.COMCOMCAST COMMERCIAL INTERNET1-855-205-6962ACCESS AND ROADHEALTH DEPARTMENT:LARIMER COUNTY HEALTH DEPARTMENT200 PERIDOT AVENUELOVELAND, CO 80537PH: (970) 498.6700FIRE DEPARTMENT:ELECTRIC:CITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: DAN MOGENPH: (970) 305.5989E: DMOGEN@FCGOV.COMPOUDRE FIRE AUTHORITYCONTACT: MARCUS GLASGOWPH: (970) 416.2869E: MARCUS.GLASGOW@POUDRE-FIRE.ORGBUILDING PERMIT:CITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: RUSSELL HOVLANDPH: (910) 416.2341E: RHOVLAND@FCGOV.COMWATER:CITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: STEVE GILCHRISTPH: (970) 224.6175E: SGILCHRIST@FCGOV.COMSTORM SEWER:CITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: ROB IRISHPH: (970) 224.6167E: RIRISH@FCGOV.COMPLANNING DEPARTMENT:CITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: BRANDY BETHUREM HARRASPH: (970) 416.2274E: BBETHUREMHARRAS@FCGOV.COMOLSSON, INC.7878 N. 16TH STREET, SUITE 105 PHOENIX, AZ85020CONTACT: AMY SCHWENNERPH: (602) 748.1000E: ASCHWENNER@OLSSON.COMCITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: DAN MOGENE: (970) 305.5989PH: DMOGEN@FCGOV.COMLOT 5 SITE DATASTORE TYPEMARKETPLACE BISTROCANOPY / DISPENSER ARRANGEMENT4 DISPENSERS(SINGLE)TYPE OF USECONVENIENCE STOREWITH FUELHEIGHTBUILDING19'-6"PARAPET20'-0"BLADE22'-6"FUEL CANOPY20'-6"GROSS FLOOR AREA3,946 SFGROSS CANOPY AREA2,592 SFGROSS LOT AREA40,012 SF 0.919 ACBUILDING COVERAGE3,946 SF (9.9%)LANDSCAPE COVERAGE9,971 (24.9%)PARKING/DRIVE/SIDEWALK COVERAGE26,095 SF (65.2%)BICYCLE PARKING2 SPACESTOTAL EMPLOYEES16-18EMPLOYEES PER SHIFT3-5HOURS OF OPERTAION5AM-11PM MON-FRI6AM-10PM SAT-SUNREQUIRED PARKINGSTANDARD8 MIN - 16 MAXADA1TOTAL8 MIN - 16 MAXPARKING RATIO = 1 STALL/200 SFPROVIDED PARKINGSTANDARD15ADA1TOTAL16PARKING RATIO = 1 STALL/247 SFZONING INFORMATIONCURRENT: NEIGHBORHOOD COMMERCIAL DISTRICT (N-C)MINIMUM LOT AREAMINIMUM LOT WIDTHSITE AREA PER UNITFRONT YARD SETBACK NORTH (FEET)15'LEFT SIDE YARD SETBACK WEST (FEET)5'RIGHT SIDE YARD SETBACK EAST (FEET)15'REAR YARD SETBACK SOUTH (FEET)5'MAXIMUM HEIGHT (FEET)NONE SPECIFIEDMAXIMUM BUILDING COVERAGE (SF)5,000 SFMAXIMUM IMPERVIOUS COVERAGE94%FLOOR AREA RATIONONE SPECIFIEDCONFIDENTIAL DOCUMENT:INFORMATION CONTAINED IN THIS DOCUMENT ISPROPRIETARY TO KUM & GO, L.C. AND SHALL NOTBE DISTRIBUTED.COVER SHEET E. PROSPECT RDS. LEMAY AVE WHERE & MEANS MORE.UTILITY PLANS FORSTORE #0951LOT 5, EAST ACRES949 E. PROSPECT ROAD FORT COLLINS, COLEGAL DESCRIPTION:LOT 5, EAST ACRES, BEING A PORTION OF THE NORTHEAST QUARTER OF SECTION 24, TOWNSHIP 7NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OFCOLORADOThese plans have been reviewed by the Local Entity forconcept only. The review does not imply responsibility bythe reviewing department, the Local Entity Engineer, orthe Local Entity for accuracy and correctness of thecalculations. Furthermore, the review does not imply thatquantities of items on the plans are the final quantitiesrequired. The review shall not be construed in any reasonas acceptance of financial responsibility by the LocalEntity for additional quantities of items shown that may berequired during the construction phase.REFERENCE REPORT OF GEOTECHNICAL EXPLORATION PREPARED BY OLSSON ON 6/24/2021VARIANCE REQUESTS1.APPLICANT HEREBY REQUESTS TO INSTALL A 40 FT WIDEDRIVEWAY WHERE 36 FT IS THE STANDARD.City of Fort Collins, ColoradoUTILITY PLAN APPROVALAPPROVED:APPROVED:APPROVED:APPROVED:APPROVED:APPROVED:Approved SheetsApproved SheetsApproved SheetsApproved SheetsApproved SheetsApproved SheetsDateDateDateDateDateDateEnvironmental Planner,Traffic Operations,Park Planning and Development,Stormwater Utility,Water & Wastewater Utility,City Engineer,FLOOD ZONE NOTE:DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAYALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTIONACTIVITY (CURB & GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKINGLOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRINGCREEK FLOOD PLAIN LIMITS AS DELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIESWITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORTCOLLINS MUNICIPAL CODE.SHEET INDEXSheet N u m be r Sheet Titl e1C0.0COVER SHEET2C0.1GENERAL NOTES3C0.2CITY GENERAL NOTES4C0.3ALTA NSPS LAND TITLE SURVEY5C0.4ALTA NSPS LAND TITLE SURVEY6C0.5DEMOLITION PLAN7C1.0PROJECT PLAN8C2.1GRADING PLAN9C2.2DETAILED GRADING PLAN10C2.3STORM SWER PLAN11C2.4STORM SEWER DETAILS12C2.5STORM SEWER DETAILS13C2.6DRAINAGE DETAILS14C2.7PH. 1 EROSION CONTROL PLAN15C2.8PH. 2 EROSION CONTROL PLAN16C2.9PH. 3 & 4 EROSION CONTROL PLAN17C2.10STD. EROSION CONTROL NOTES18C2.11EROSION CONTROL DETAILS19C2.12EROSION CONTROL DETAILS20C3.1UTILITY SERVICE PLAN21C3.2UTILITY DETAILS22C3.3UTILITY DETAILS23C4.1HORIZONTAL CONTROL PLAN24C4.2DETAILED HORIZONTAL CONTROLPLAN25C4.3HORIZONTAL CONTROL POINTTABLES26C4.4FLOWLINE PLAN & PROFILE27C4.5SIGNAGE AND STRIPING PLAN28C4.6ADA PLAN29C4.7PAVING DETAILS30C4.8PAVING DETAILS31C4.9PAVING DETAILS32C4.10SIGNAGE & SITE DETAILS33C5.0TRAFFIC SIGNAL PLAN34L1.0TREE REMOVAL PLAN35L1.1FINAL LANDSCAPE PLAN36L1.2HYDROZONE PLAN37L1.3LANDSCAPE DETAILS38I1.1FINAL IRRIGATION PLAN39I1.2IRRIGATION DETAILS 140I1.3IRRIGATION DETAILS 2BENCHMARKS:PROJECT BENCHMARK: NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88)SITE BENCHMARK: CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88)ELEVATIONS BROUGHT TO THE SITE VIA GPS OBSERVATIONS USING THE TRIMBLE VRS NETWORK"I hereby affirm that these final construction plans wereprepared under my supervision, in accordance with allapplicable City of Fort Collins and State of ColoradoStandards and statutes, respectively; and that I am fullyresponsible for the accuracy of all design, revisions, andrecord conditions that I noted on these plans."DATEENGINEERC0.01CITY OF FORT COLLINS281 N COLLEGE AVEFORT COLLINS, CO 80522CONTACT: DAN MOGENE: (970) 305.5989PH: DMOGEN@FCGOV.COM4/04/2023Does not match the required format.See written comments.SpellingThis project is being replatted, and should be"KUM & GO 951 SUBDIVISION".Should match the Subdivision Plat. SHEET NUMBER:CPM: SDM: RDM:03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT 1459 Grand AvenueDes Moines, Iowa50309P: 515-226-0128F: 515-223-9873DATE:TCDGBSCALL 811 SEVENTY-TWO HOURS PRIOR TODIGGING, GRADING OR EXCAVATING FOR THEMARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013 Know what'sbelow.before you dig.CallRwww.olsson.comTEL 303.237.2072 1525 Raleigh St. Suite 400 Denver, CO 80204 DATE REVISION DESCRIPTION OF 40GENERAL NOTES1.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF PUBLIC IMPROVEMENTS SHALL MEET OR EXCEEDTHE STANDARDS AND SPECIFICATIONS SET FORTH IN THE LARIMER COUNTY URBAN AREA STREETSTANDARDS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEENTHESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE MOST RESTRICTIVESTANDARD SHALL APPLY. ALL WORK SHALL BE INSPECTED AND APPROVED BY THE LOCAL ENTITY.2.ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAIDSTANDARD, UNLESS SPECIFICALLY STATED OTHERWISE.3.THESE PUBLIC IMPROVEMENT CONSTRUCTION PLANS SHALL BE VALID FOR A PERIOD OF THREE YEARSFROM THE DATE OF APPROVAL BY THE LOCAL ENTITY ENGINEER. USE OF THESE PLANS AFTER THEEXPIRATION DATE WILL REQUIRE A NEW REVIEW AND APPROVAL PROCESS BY THE LOCAL ENTITY PRIOR TOCOMMENCEMENT OF ANY WORK SHOWN IN THESE PLANS.4.THE ENGINEER WHO HAS PREPARED THESE PLANS, BY EXECUTION AND/OR SEAL HEREOF, DOES HEREBYAFFIRM RESPONSIBILITY TO THE LOCAL ENTITY, AS BENEFICIARY OF SAID ENGINEER’S WORK,FOR ANYERRORS AND OMISSIONS CONTAINED IN THESE PLANS, AND APPROVAL OF THESE PLANS BY THE LOCALENTITY ENGINEER SHALL NOT RELIEVE THE ENGINEER WHO HAS PREPARED THESE PLANS OF ALL SUCHRESPONSIBILITY. FURTHER, TO THE EXTENT PERMITTED BY LAW, THE ENGINEER HEREBY AGREES TO HOLDHARMLESS AND INDEMNIFY THE LOCAL ENTITY, AND ITS OFFICERS AND EMPLOYEES, FROM AND AGAINSTALL LIABILITIES, CLAIMS, AND DEMANDS WHICH MAY ARISE FROM ANY ERRORS AND OMISSIONS CONTAINEDIN THESE PLANS.5.ALL SANITARY SEWER, STORM SEWER, AND WATER LINE CONSTRUCTION, AS WELL AS POWER AND OTHER“DRY” UTILITY INSTALLATIONS, SHALL CONFORM TO THE LOCAL ENTITY STANDARDS AND SPECIFICATIONSCURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL ENTITY ENGINEER.6.THE TYPE, SIZE, LOCATION AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATEWHEN SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER TO VERIFY THEEXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK BEFORECOMMENCING NEW CONSTRUCTION. THE DEVELOPER SHALL BE RESPONSIBLE FOR UNKNOWNUNDERGROUND UTILITIES.7.THE ENGINEER SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) AT1-800-922-1987, AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING EXCAVATION OR GRADING, TO HAVE ALLREGISTERED UTILITY LOCATIONS MARKED. OTHER UNREGISTERED UTILITY ENTITIES (I.E. DITCH / IRRIGATIONCOMPANY) ARE TO BE LOCATED BY CONTACTING THE RESPECTIVE REPRESENTATIVE. UTILITY SERVICELATERALS ARE ALSO TO BE LOCATED PRIOR TO BEGINNING EXCAVATION OR GRADING. IT SHALL BE THERESPONSIBILITY OF THE DEVELOPER TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THEPROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.8.THE DEVELOPER SHALL BE RESPONSIBLE FOR PROTECTING ALL UTILITIES DURING CONSTRUCTION AND FORCOORDINATING WITH THE APPROPRIATE UTILITY COMPANY FOR ANY UTILITY CROSSINGS REQUIRED.9.IF A CONFLICT EXISTS BETWEEN EXISTING AND PROPOSED UTILITIES AND/OR A DESIGN MODIFICATION ISREQUIRED, THE DEVELOPER SHALL COORDINATE WITH THE ENGINEER TO MODIFY THE DESIGNMODIFICATION(S) MUST BE APPROVED BY THE LOCAL ENTITY PRIOR TO BEGINNING CONSTRUCTION.10.THE DEVELOPER SHALL COORDINATE AND COOPERATE WITH THE LOCAL ENTITY, AND ALL UTILITYCOMPANIES INVOLVED, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION AND WITH AMINIMUM DISRUPTION OF SERVICE. THE DEVELOPER SHALL BE RESPONSIBLE FOR CONTACTING, INADVANCE, ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE AS WELL AS THE UTILITYCOMPANIES.11.NO WORK MAY COMMENCE WITHIN ANY PUBLIC STORM WATER, SANITARY SEWER OR POTABLE WATERSYSTEM UNTIL THE DEVELOPER NOTIFIES THE UTILITY PROVIDER. NOTIFICATION SHALL BE A MINIMUM OF 2WORKING DAYS PRIOR TO COMMENCEMENT OF ANY WORK. AT THE DISCRETION OF THE WATER UTILITYPROVIDER, A PRE-CONSTRUCTION MEETING MAY BE REQUIRED PRIOR TO COMMENCEMENT OF ANY WORK.12.THE DEVELOPER SHALL SEQUENCE INSTALLATION OF UTILITIES IN SUCH A MANNER AS TO MINIMIZEPOTENTIAL UTILITY CONFLICTS. IN GENERAL, STORM SEWER AND SANITARY SEWER SHOULD BECONSTRUCTED PRIOR TO INSTALLATION OF THE WATER LINES AND DRY UTILITIES.13.THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESSOTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY.14.A STATE CONSTRUCTION DEWATERING WASTEWATER DISCHARGE PERMIT IS REQUIRED IF DEWATERING ISREQUIRED IN ORDER TO INSTALL UTILITIES OR WATER IS DISCHARGED INTO A STORM SEWER, CHANNEL,IRRIGATION DITCH OR ANY WATERS OF THE UNITED STATES.15.THE DEVELOPER SHALL COMPLY WITH ALL TERMS AND CONDITIONS OF THE COLORADO PERMIT FOR STORMWATER DISCHARGE (CONTACT COLORADO DEPARTMENT OF HEALTH, WATER QUALITY CONTROL DIVISION,(303) 692-3590), THE STORM WATER MANAGEMENT PLAN, AND THE EROSION CONTROL PLAN.16.THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGE FACILITIESLOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THERESPONSIBILITY OF THE PROPERTY OWNER(S).17.PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE LOCAL ENTITY, CERTIFICATION OF THE DRAINAGEFACILITIES, BY A REGISTERED ENGINEER, MUST BE SUBMITTED TO AND APPROVED BY THE STORMWATERUTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITY DEPARTMENT ATLEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FOR SINGLE FAMILY UNITS.FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITYDEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDING PERMITS IN EXCESS OFTHOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT.18.THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES OR INJURIES SUSTAINED IN THISDEVELOPMENT AS A RESULT OF GROUNDWATER SEEPAGE, WHETHER RESULTING FROM GROUNDWATERFLOODING, STRUCTURAL DAMAGE OR OTHER DAMAGE UNLESS SUCH DAMAGE OR INJURIES ARE SUSTAINEDAS A RESULT OF THE LOCAL ENTITY FAILURE TO PROPERLY MAINTAIN ITS WATER, WASTEWATER, AND/ORSTORM DRAINAGE FACILITIES IN THE DEVELOPMENT.19.ALL RECOMMENDATIONS OF THE FINAL DRAINAGE REPORT FOR THE PROJECT SHALL BE FOLLOWED ANDIMPLEMENTED.20.TEMPORARY EROSION CONTROL DURING CONSTRUCTION SHALL BE PROVIDED AS SHOWN ON THE EROSIONCONTROL PLAN. ALL EROSION CONTROL MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THEDEVELOPER, UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS IS STABILIZED WITH HARD SURFACE ORLANDSCAPING.21.THE DEVELOPER SHALL BE RESPONSIBLE FOR INSURING THAT NO MUD OR DEBRIS SHALL BE TRACKEDONTO THE EXISTING PUBLIC STREET SYSTEM. MUD AND DEBRIS MUST BE REMOVED WITHIN 24 HOURS BY ANAPPROPRIATE MECHANICAL METHOD (I.E. MACHINE BROOM SWEEP, LIGHT DUTY FRONT-END LOADER, ETC.)OR AS APPROVED BY THE LOCAL ENTITY STREET INSPECTOR.22.NO WORK MAY COMMENCE WITHIN ANY IMPROVED OR UNIMPROVED PUBLIC RIGHT-OF-WAY UNTIL ARIGHT-OF-WAY PERMIT OR DEVELOPMENT CONSTRUCTION PERMIT IS OBTAINED, IF APPLICABLE.23.THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FOR ALL APPLICABLEAGENCIES PRIOR TO COMMENCEMENT OF CONSTRUCTION. THE DEVELOPER SHALL NOTIFY THE LOCALENTITY ENGINEERING INSPECTOR (FORT COLLINS - 221-6605) AND THE LOCAL ENTITY EROSION CONTROLINSPECTOR (FORT COLLINS – 221-6700) AT LEAST 2 WORKING DAYS PRIOR TO THE START OF ANY EARTHDISTURBING ACTIVITY, OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS. IF THE LOCAL ENTITYENGINEER IS NOT AVAILABLE AFTER PROPER NOTICE OF CONSTRUCTION ACTIVITY HAS BEEN PROVIDED,THE DEVELOPER MAY COMMENCE WORK IN THE ENGINEER ABSENCE. HOWEVER, THE LOCAL ENTITYRESERVES THE RIGHT NOT TO ACCEPT THE IMPROVEMENT IF SUBSEQUENT TESTING REVEALS ANIMPROPER INSTALLATION.24.THE DEVELOPER SHALL BE RESPONSIBLE FOR OBTAINING SOILS TESTS WITHIN THE PUBLIC RIGHTOF-WAYAFTER RIGHT OF WAY GRADING AND ALL UTILITY TRENCH WORK IS COMPLETE AND PRIOR TO THEPLACEMENT OF CURB, GUTTER, SIDEWALK AND PAVEMENT. IF THE FINAL SOILS/PAVEMENT DESIGN REPORTDOES NOT CORRESPOND WITH THE RESULTS OF THE ORIGINAL GEOTECHNICAL REPORT, THE DEVELOPERSHALL BE RESPONSIBLE FOR A RE-DESIGN OF THE SUBJECT PAVEMENT SECTION OR, THE DEVELOPER MAYUSE THE LOCAL ENTITY’S DEFAULT PAVEMENT THICKNESS SECTION(S). REGARDLESS OF THE OPTION USED,ALL FINAL SOILS/PAVEMENT DESIGN REPORTS SHALL BE PREPARED BY A LICENSED PROFESSIONALENGINEER. THE FINAL REPORT SHALL BE SUBMITTED TO THE INSPECTOR A MINIMUM OF 10 WORKING DAYSPRIOR TO PLACEMENT OF BASE AND ASPHALT. PLACEMENT OF CURB, GUTTER, SIDEWALK, BASE ANDASPHALT SHALL NOT OCCUR UNTIL THE LOCAL ENTITY ENGINEER APPROVES THE FINAL REPORT.25.THE CONTRACTOR SHALL HIRE A LICENSED ENGINEER OR LAND SURVEYOR TO SURVEY THE CONSTRUCTEDELEVATIONS OF THE STREET SUBGRADE AND THE GUTTER FLOWLINE AT ALL INTERSECTIONS, INLETS, ANDOTHER LOCATIONS REQUESTED BY THE LOCAL ENTITY INSPECTOR. THE ENGINEER OR SURVEYOR MUSTCERTIFY IN A LETTER TO THE LOCAL ENTITY THAT THESE ELEVATIONS CONFORM TO THE APPROVED PLANSAND SPECIFICATIONS. ANY DEVIATIONS SHALL BE NOTED IN THE LETTER AND THEN RESOLVED WITH THELOCAL ENTITY BEFORE INSTALLATION OF BASE COURSE OR ASPHALT WILL BE ALLOWED ON THE STREETS.26.26. ALL UTILITY INSTALLATIONS WITHIN OR ACROSS THE ROADBED OF NEW RESIDENTIAL ROADS MUST BECOMPLETED PRIOR TO THE FINAL STAGES OF ROAD CONSTRUCTION. FOR THE PURPOSES OF THESESTANDARDS, ANY WORK EXCEPT C/G ABOVE THE SUBGRADE IS CONSIDERED FINAL STAGE WORK. ALLSERVICE LINES MUST BE STUBBED TO THE PROPERTY LINES AND MARKED SO AS TO REDUCE THEEXCAVATION NECESSARY FOR BUILDING CONNECTIONS.27.PORTIONS OF LARIMER COUNTY ARE WITHIN OVERLAY DISTRICTS. THE LARIMER COUNTY FLOODPLAINRESOLUTION SHOULD BE REFERRED TO FOR ADDITIONAL CRITERIA FOR ROADS WITHIN THESE DISTRICTS.28.ALL ROAD CONSTRUCTION IN AREAS DESIGNATED AS WILD FIRE HAZARD AREAS SHALL BE DONE INACCORDANCE WITH THE CONSTRUCTION CRITERIA AS ESTABLISHED IN THE WILD FIRE HAZARD AREAMITIGATION REGULATIONS IN FORCE AT THE TIME OF FINAL PLAT APPROVAL.29.PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION, THE CONTRACTOR SHALL CONTACT THE LOCALENTITY FORESTER TO SCHEDULE A SITE INSPECTION FOR ANY TREE REMOVAL REQUIRING A PERMIT.30.THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO,EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. REFER TO OSHA PUBLICATION2226, EXCAVATING AND TRENCHING.31.THE DEVELOPER SHALL SUBMIT A CONSTRUCTION TRAFFIC CONTROL PLAN, IN ACCORDANCE WITH MUTCD,TO THE APPROPRIATE RIGHT-OF-WAY AUTHORITY. (LOCAL ENTITY, COUNTY OR STATE), FOR APPROVAL,PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN, OR AFFECTING, THE RIGHT-OF-WAY. THE DEVELOPERSHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BYTHE CONSTRUCTION ACTIVITIES.32.PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION THAT WILL AFFECT TRAFFIC SIGNS OF ANY TYPE,THE CONTRACTOR SHALL CONTACT LOCAL ENTITY TRAFFIC OPERATIONS DEPARTMENT, WHO WILLTEMPORARILY REMOVE OR RELOCATE THE SIGN AT NO COST TO THE CONTRACTOR; HOWEVER, IF THECONTRACTOR MOVES THE TRAFFIC SIGN THEN THE CONTRACTOR WILL BE CHARGED FOR THE LABOR,MATERIALS AND EQUIPMENT TO REINSTALL THE SIGN AS NEEDED.33.THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR THE INITIAL INSTALLATION OF TRAFFIC SIGNING ANDSTRIPING FOR THE DEVELOPMENT RELATED TO THE DEVELOPMENT’S LOCAL STREET OPERATIONS. INADDITION, THE DEVELOPER IS RESPONSIBLE FOR ALL COSTS FOR TRAFFIC SIGNING AND STRIPING RELATEDTO DIRECTING TRAFFIC ACCESS TO AND FROM THE DEVELOPMENT.34.THERE SHALL BE NO SITE CONSTRUCTION ACTIVITIES ON SATURDAYS, UNLESS SPECIFICALLY APPROVED BYTHE LOCAL ENTITY ENGINEER, AND NO SITE CONSTRUCTION ACTIVITIES ON SUNDAYS OR HOLIDAYS, UNLESSTHERE IS PRIOR WRITTEN APPROVAL BY THE LOCAL ENTITY.35.THE DEVELOPER IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THECOMPLETION OF THE INTENDED IMPROVEMENTS, SHOWN ON THESE DRAWINGS, OR DESIGNATED TO BEPROVIDED, INSTALLED, OR CONSTRUCTED, UNLESS SPECIFICALLY NOTED OTHERWISE.36.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. IF PERTINENTDIMENSIONS ARE NOT SHOWN, CONTACT THE DESIGNER FOR CLARIFICATION, AND ANNOTATE THEDIMENSION ON THE AS-BUILT RECORD DRAWINGS.37.THE DEVELOPER SHALL HAVE, ONSITE AT ALL TIMES, ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE(1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND A COPY OF ANY PERMITS ANDEXTENSION AGREEMENTS NEEDED FOR THE JOB. 38. IF, DURING THE CONSTRUCTION PROCESS,CONDITIONS ARE ENCOUNTERED WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THEPLANS OR SPECIFICATIONS, THE DEVELOPER SHALL CONTACT THE DESIGNER AND THE LOCAL ENTITYENGINEER IMMEDIATELY.39.THE DEVELOPER SHALL BE RESPONSIBLE FOR RECORDING AS-BUILT INFORMATION ON A SET OF RECORDDRAWINGS KEPT ON THE CONSTRUCTION SITE, AND AVAILABLE TO THE LOCAL ENTITY’S INSPECTOR AT ALLTIMES. UPON COMPLETION OF THE WORK, THE CONTRACTOR(S) SHALL SUBMIT RECORD DRAWINGS TO THELOCAL ENTITY ENGINEER.40.THE DESIGNER SHALL PROVIDE, IN THIS LOCATION ON THE PLAN, THE LOCATION AND DESCRIPTION OF THENEAREST SURVEY BENCHMARKS (2) FOR THE PROJECT AS WELL AS THE BASIS OF BEARINGS. THEINFORMATION SHALL BE AS FOLLOWS:BENCHMARKS—LOCAL ENTITY SURVEY.NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88)CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88)41.ALL STATIONING IS BASED ON FLOWLINE OF ROADWAYS UNLESS OTHERWISE NOTED.42.DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS EXISTINGFENCES, TREES, STREETS, SIDEWALKS, CURBS AND GUTTERS, LANDSCAPING, STRUCTURES, ANDIMPROVEMENTS DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BEREPLACED OR RESTORED IN LIKE KIND AT THE DEVELOPER’S EXPENSE, UNLESS OTHERWISE INDICATED ONTHESE PLANS, PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THEISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.43.WHEN AN EXISTING ASPHALT STREET MUST BE CUT, THE STREET MUST BE RESTORED TO A CONDITIONEQUAL TO OR BETTER THAN ITS ORIGINAL CONDITION. THE EXISTING STREET CONDITION SHALL BEDOCUMENTED BY THE LOCAL ENTITY CONSTRUCTION INSPECTOR BEFORE ANY CUTS ARE MADE. PATCHINGSHALL BE DONE IN ACCORDANCE WITH THE LOCAL ENTITY STREET REPAIR STANDARDS. THE FINISHEDPATCH SHALL BLEND IN SMOOTHLY INTO THE EXISTING SURFACE. ALL LARGE PATCHES SHALL BE PAVEDWITH AN ASPHALT LAY-DOWN MACHINE. IN STREETS WHERE MORE THAN ONE CUT IS MADE, AN OVERLAY OFTHE ENTIRE STREET WIDTH, INCLUDING THE PATCHED AREA, MAY BE REQUIRED. THE DETERMINATION OFNEED FOR A COMPLETE OVERLAY SHALL BE MADE BY THE LOCAL ENTITY ENGINEER AND/OR THE LOCALENTITY INSPECTOR AT THE TIME THE CUTS ARE MADE.44.UPON COMPLETION OF CONSTRUCTION, THE SITE SHALL BE CLEANED AND RESTORED TO A CONDITIONEQUAL TO, OR BETTER THAN, THAT WHICH EXISTED BEFORE CONSTRUCTION, OR TO THE GRADES ANDCONDITION AS REQUIRED BY THESE PLANS.45.STANDARD HANDICAP RAMPS ARE TO BE CONSTRUCTED AT ALL CURB RETURNS AND AT ALL “T”INTERSECTIONS.46.AFTER ACCEPTANCE BY THE LOCAL ENTITY, PUBLIC IMPROVEMENTS DEPICTED IN THESE PLANS SHALL BEGUARANTEED TO BE FREE FROM MATERIAL AND WORKMANSHIP DEFECTS FOR A MINIMUM PERIOD OF TWOYEARS FROM THE DATE OF ACCEPTANCE.47.THE LOCAL ENTITY SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF ROADWAY AND APPURTENANTIMPROVEMENTS, INCLUDING STORM DRAINAGE STRUCTURES AND PIPES, FOR THE FOLLOWING PRIVATESTREETS:N/A48.APPROVED VARIANCES ARE LISTED AS FOLLOWS: 40' DRIVEWAY WIDTHSITE PLAN NOTES1.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORMDRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.2.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OFALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.3.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THEPLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGESTO THE PLANS.4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROMADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISHSUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OFTHE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS ANDPLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES.5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS APHASING PLAN IS SHOWN WITH THESE PLANS.6.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARPCUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.7.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVEDBY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESSA SPECIFIC VARIANCE IS GRANTED BY THE CITY.8.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUSTPROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM.9.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED.10.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSABLE RAMPS MUST BEPROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKINGSPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALLACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN1:48 CROSS SLOPE.11.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFICCIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THE PROPERTYOWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALLADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS.12.DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALLBE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINALPLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER.13.THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREETSIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT.14.PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVECOVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCEDHAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING,SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHESLINES (IF LOCATED IN BACK YARDS), ODOR-CONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OFREQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS.15.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THISPROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'SEXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OFTHE FIRST CERTIFICATE OF OCCUPANCY.16.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIALPRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODEOFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRELANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBITTHE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED INA CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TOPROVIDE ADEQUATE VISIBILITY.17.PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THECITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESSTHE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALLBUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATIONPLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THEPROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND.WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLICWAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.STREET TREE NOTES1.A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ONTHIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONESBETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVETHE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITYOF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING ORRELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY.2.CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACHPHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVALOF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE.3.STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITYCODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORTCOLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTEDBY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR.4.THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINALMAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALLSTREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLECONDITION PRIOR TO ACCEPTANCE.5.SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TOACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS ANDSTREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE.QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TOMEET SEPARATION STANDARDS.TREE PROTECTION NOTES1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFERZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL.2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER AFOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THEDISTURBANCE.3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS.TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OFFORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTINGTREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT,SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUCK OR ONE-HALF (12) OF THEDRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT,MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE.5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OFEQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS,SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREEWITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LANDCLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF" RATHER THANERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAYBE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYINGRIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEINGCLEARED.8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRINGEXCAVATION DEEPER THAN SIC (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEMOF PROTECTED EXISTING TREES AT A MINIUMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGERDISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREEDIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW:9.ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD SEASON (FEB1-JULY 31) ORCONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA.GENERAL LANDSCAPE NOTES1.PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OFNORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THEAMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OREQUIVALENT.2.IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREASSHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWEDAND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OFA BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATIONSYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH ANAUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BYTHE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATERREQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. IRRIGATION SYSTEMS TO BE TURNED OVER TO THECITY PARKS DEPARTMENT FOR MAINTENANCE MUST BE APPROVED BY THE PARKS MANAGER AND MEETPARKS IRRIGATION STANDARDS. DESIGN REVIEW SHALL OCCUR DURING UTILITIES DEPARTMENTIRRIGATION REVIEW PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND CONSTRUCTION OBSERVATIONAND INSPECTION BY PARKS SHALL BE INCORPORATED INTO THE CONSTRUCTION PROCESS.3.TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTIONACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING.4.SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITYCODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BETHOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BETHOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6)INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDSOF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THEISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THECITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THESOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132.5.INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUNDHORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHYGROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BESECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OFOCCUPANCY FOR ANY BUILDING IN SUCH PHASE.6.MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPEELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAMEMANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER ORSUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULARMAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BEMAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH ASFENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLYSOUND CONDITION.7.REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLYREPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS.8.THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES:40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES.4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES4 FEET BETWEEN TREES AND GAS LINES9.ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYSAND ALLEYS PER LUC 3.2.1(D)(2)(A).10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA ASSPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24"SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OFDECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCESWITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF ANOPEN DESIGN.11.THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THEPROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICTWITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN.12.MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIREDBY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUSTBE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDEDIN THE PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANTSPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION.13.ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES.NATURAL AREA BUFFER NOTES1.STANDARDS FOR PROTECTION DURING CONSTRUCTION - THE DIRECTOR SHALL ESTABLISH A "LIMITS OFDEVELOPMENT" ("LOD") LINE(S) TO ESTABLISH THE BOUNDARY OF THE PROJECT OUTSIDE OF WHICH NOLAND DISTURBANCE ACTIVITIES WILL OCCUR DURING THE CONSTRUCTION OF THE PROJECT.2.SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE BUFFER ZONE.3.CONSTRUCTION SHALL BE ORGANIZED AND TIMED TO MINIMIZE THE DISTURBANCE OF SENSITIVE SPECIESOCCUPYING OR USING ON-SITE AND ADJACENT NATURAL HABITATS OR FEATURES.4.CONSTRUCTION OF BARRIER FENCING SHALL BE PROVIDED AT THE LIMITS OF THE DEVELOPMENT DURINGCONSTRUCTION.FLOODPLAIN AND FLOODWAY NOTES1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YEAR SPRING CREEKFLOODPLAIN.2.DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALLAPPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (CURB &GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRING CREEK FLOODPLAIN LIMITS ASDELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECTTO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.3.CONSTRUCTION OF RESIDENTIAL STRUCTURES IS NOT ALLOWED IN THE 100 YEAR FLOODWAY.4.RESIDENTIAL STRUCTURES ARE ALLOWED IN THE 100 YEAR HIGH RISK FLOOD FRINGE PROVIDED THEY MEETALL ELEVATION REQUIREMENTS OF CHAPTER 10 OF THE CITY MUNICIPAL CODE.5.NON-STRUCTURAL DEVELOPMENT (FENCES, DETENTION PONDS, HARD SURFACE PATHS, FILL, DRIVEWAYS,PARKING AREA, VEGETATION, ETC.) IS ALLOWED WITHIN THE 100 YEAR FLOODWAY, PROVIDED THEDEVELOPMENT WILL NOT CAUSE A RISE IN THE BASE FLOOD ELEVATION OR A CHANGE TO THE FLOODWAYOR FLOOD FRINGE BOUNDARIES. NON-STRUCTURAL DEVELOPMENT IS NOT RESTRICTED IN THE FLOODFRINGE.STORM DRAINAGE NOTES1.THE CITY OF FORT COLLINS SHALL NOT BE RESPONSIBLE FOR THE MAINTENANCE OF STORM DRAINAGEFACILITIES LOCATED ON PRIVATE PROPERTY. MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THERESPONSIBILITY OF THE PROPERTY OWNER(S).2.ALL RECOMMENDATIONS OF THE FINAL DRAINAGE AND EROSION CONTROL STUDY (NAME OF THE STUDYAND DATE) BY (ENGINEERING FIRM) SHALL BE FOLLOWED AND IMPLEMENTED.3.PRIOR TO FINAL INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS, CERTIFICATION OF THEDRAINAGE FACILITIES, BY A REGISTERED ENGINEER, MUST BY SUBMITTED TO AND APPROVED BY THESTORMWATER UTILITY DEPARTMENT. CERTIFICATION SHALL BE SUBMITTED TO THE STORMWATER UTILITYDEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF A CERTIFICATE OF OCCUPANCY FORSINGLE FAMILY UNITS. FOR COMMERCIAL PROPERTIES, CERTIFICATION SHALL BY SUBMITTED TO THESTORMWATER UTILITY DEPARTMENT AT LEAST TWO WEEKS PRIOR TO THE RELEASE OF ANY BUILDINGPERMITS IN EXCESS OF THOSE ALLOWED PRIOR TO CERTIFICATION PER THE DEVELOPMENT AGREEMENT.4.SEE CITY OF FORT COLLINS STORMWATER CRITERIA MANUAL – APPENDIX F CONSTRUCTION CONTROLMEASURES STANDARD NOTES AND STANDARD EROSION CONTROL NOTES.WATERLINE NOTES1.THE MINIMUM COVER OVER WATER LINES IS 4.5 FEET AND THE MAXIMUM COVER IS 5.5 FEET UNLESSOTHERWISE NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY.CONFIDENTIAL DOCUMENT:INFORMATION CONTAINED IN THIS DOCUMENT ISPROPRIETARY TO KUM & GO, L.C. AND SHALL NOTBE DISTRIBUTED.CITY GENERAL NOTESC0.23TREE DIAMETER OR BREAST HEIGHT (INCHES)AUGER DISTANCE FROM FACE OF TREE (FT)0-213-425-9510-141015-1912OVER19154/04/2023Does not match therequired format. Seewritten comments. C0.3 4 OF 40 03/03/2023 PARCEL No. 9724135000 OWNER: N/A -DUNLAP PARCEL 2- PARCEL No. 9724105001 ADDRESS: 949 E PROSPECT ROAD OWNERS: DUNLAP RICHARD W CITY ZONING: N-C FLOOD ZONE X 1.46 Acres (63,549 sq.ft.) Gross 1.20 Acres (52,347 sq.ft.) Net* Prospect Road (70' Right-of-Way Width) -35MPH Speed Limit- -SUBJECT PROPERTY- LOT 5, EAST ACRES PARCEL No. 9724106004 OWNER: MATLOCK JAMES J -DUNLAP PARCEL 1- PARCEL No. 9724106017 ADDRESS: 947 E PROSPECT ROAD OWNERS: DUNLAP RICHARD W AND PAMELA S CITY ZONING: N-C FLOOD ZONE X -CITY OF FORT COLLINS PARCEL- PARCEL No. 9724106905 ADDRESS: 945 E PROSPECT ROAD OWNERS: CITY OF FORT COLLINS CITY ZONING: N-C FLOOD ZONE X & AE -DUNLAP PARCEL 3- PARCEL No. 9724106016 ADDRESS: 1607 S LEMAY AVENUE OWNERS: DUNLAP RICHARD W CITY ZONING: N-C FLOOD ZONE X & AE PARCEL No. 9724132000 OWNER: N/A PARCEL No. 9724106006 OWNER: RHT LLC PARCEL No. 9724106030 OWNER: RHT LLC PARCEL No.8719233006 OWNER: PARK CENTRAL OWNERS ASSN PARCEL No.8719233001 OWNER: BRUNNER KENTON H (1/2) PARCEL No. 8718332004 OWNER: SURGERY CENTER OF FORT COLLINS LLCPARCEL No. 9713408192 OWNER: PRD PROPERTIES LLCPARCEL No. 9713408193 OWNER: PLAUT JOSETTE M Lake StreetLemay Avenue(Right-of-Way Width Varries)-35MPH Speed Limit-REVISIONSDATEREVISION DESCRIPTIONSHEET NUMBER: CPM: SDM: RDR: 11/24/2020#951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT ST, FORT COLLINS6400 Westown Parkway West Des Moines, Iowa 50266 P: 515-226-0128 F: 515-223-9873 DATE: ROBERT FIEBIG III RYAN HALDER DAN GARNEAU CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. before you dig.CallR ALTA/NSPS LAND TITLE SURVEY1 OF 2 ALTA/NSPS LAND TITLE SURVEY KUM & GO #951 Lot 5, East Acres, Being a Portion of the Northeast Quarter of Section 24, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado VICINITY MAP LEGEND PROSPECT ROAD LEMAY AVENUESTUART STREET PIT K I N S T R E E T RI V E R S I D E S T R E E T ELIZABETH STREET 4/04/2023 Text Over Text C0.4 5 OF 40 03/03/2023 Prospect Road (70' Right-of-Way Width) -35MPH Speed Limit-Lake StreetD D A A D C D D C A AA A A B BB C B B C A A C B D B D D B D D C C A AB B C B B B A A B A D A D D D D D D DD D C D B AB B A A B C A C B C B B B Lemay Avenue(Right-of-Way Width Varries)-35MPH Speed Limit-REVISIONSDATEREVISION DESCRIPTIONSHEET NUMBER: KG PROJECT TEAM: 6400 Westown Parkway West Des Moines, Iowa 50266 P: 515-226-0128 F: 515-223-9873 DATE: CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. before you dig.CallR ALTA/NSPS LAND TITLE SURVEY KUM & GO #951 Lot 5, East Acres, Being a Portion of the Northeast Quarter of Section 24, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado LEGEND DETAIL B 11/24/2020#951 - FORT COLLINS, CO949 E PROSPECT ST, FORT COLLINSALTA/NSPS LAND TITLE SURVEY2 OF 2 DETAIL A CPM: SDM: RDR:ROBERT FIEBIG III RYAN HALDER DAN GARNEAU 4/04/2023 Text Over Text VAN 11 E PROSPECT RD S LEMAY AVE2 3 T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 SECTION 1 4945 4950 4955 4960 4965 4970 4975 4945 4950 4955 4960 4965 4970 4975 0+00 1+00 1+20.16 SECTION 2 4945 4950 4955 4960 4965 4970 4975 4945 4950 4955 4960 4965 4970 4975 0+00 1+00 1+31.34DOCUMENT REVISION DATE: JULY 2013EXISTING PROPERTY LINE BASIS OF BEARING: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO.PROJECT PLANPROPERTY BOUNDARY PROPOSED SETBACK LINE EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER ADA ACCESSIBLE ROUTE COLORED CONCRETE PAVEMENT PROPOSED INTEGRAL CURB PARKING COUNT GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURESTORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR PROPOSED BOLLARD PROPOSED TRANSFORMER SIGHT TRIANGLE GUY WIRE POWER POLE LEGEND GRATED STORM INLET SAWCUT LINE SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 FLAG NOTES: NOT USED PROPOSED 7' MONUMENT SIGN, OWNER SUPPLIED & CONTRACTOR INSTALLED (SEE DETAIL SHEET C4.7) PROPOSED DUO-GARD APEX BIKE SHELTER WITH (3) U-STYLE BIKE RACKS SPACED 30" APART (SEE DETAIL SHEET C4.7) PROPOSED 15' X 25' TRASH ENCLOSURE WITH NICHIHA (SEE ARCHITECTURAL PLANS FOR DETAILS) PROPOSED AIR MACHINE ON 4' X 4' PAD (SEE DETAIL SHEET C4.5) PROPOSED 4" BUILDING SIDEWALK (SEE SHEET C4.6) PROPOSED INTEGRAL CURB (SEE SHEET C4.5) PROPOSED ZERO CURB WITH BOLLARDS, 5' SPACING (TYP) (SEE SHEET C4.5) PROPOSED ADA RAMP (SEE SHEET C4.5) PROPOSED FIRE HYDRANT (SEE SHEET C3.1) PROPOSED PORTLAND CEMENT CONCRETE PAVEMENT (SEE SHEET C4.1) PROPOSED UNDERGROUND DETENTION PAINT CURB ALONG FRONT OF TANKS YELLOW PROPOSED SITE SIDEWALK PROPANE CAGE (SEE SHEET C4.9) ICE MERCHANDISE FIREWOOD MISCELLANEOUS MERCHANDISE PROPOSED 4'X8' TREE GRATE PROPOSED RIGHT TURN LANE (SEE SHEETS C4.4 & C4.5) PROPOSED CITY CURB & GUTTER (SEE SHEETS C4.4 & C4.5) 10' PROPOSED SIDEWALK/BIKE LANE (SEE SHEETS C4.1) PROPOSED FULL MOVEMENT ACCESS 100-YEAR SPRING CREEK FLOODPLAIN EXISTING LOT FOR CITY HISTORICAL HOUSE TO REMAIN CONNECT TO EXISTING CURB & GUTTER CONNECT TO EXISTING SIDEWALK SIGHT DISTANCE TRIANGLE LENGTH PER PLAN REMOTE FILL LIDS (SEE PETRO PLANS FOR DETAILS) PROPOSED 6" ROLLOVER CURB (SEE SHEET C4.5) 12' X 60' DELIVERY VEHICLE LOADING ZONE (SEE SHEET C4.1) PROPOSED ELECTRIC TRANSFORMER WITH BOLLARDS (SEE SHEET C3.1) TRANSITIONS FROM ROLLOVER TO VERTICAL CURB IN 3' SAWCUT LINE, CONTRACTOR TO SAWCUT EXISTING ASPHALT TO A CLEAN STRAIGHT EDGE PROPOSED SITE LIGHT POLE (SEE SHEET C3.1) PROPOSED 8'X30' BUS STOP PAD PROPOSED FIRE LANE SIGN (SEE SHEET C4.10) PROPOSED DRAINAGE EASEMENT PROPOSED SCREENWALL (SEE SHEET L1.3) PROPOSED 2' CURB CUT PROPOSED FENCE (SEE SHEET L1.3) PROPOSED ELECTRIC VEHICLE (EV) CHARGING STALL PROPOSED 2'x3' PAD FOR EV DUAL PLUG LEVEL 1 CHARGER W/ BOLLARDS NOTES: 1.FIRE LANES SHALL BE DESIGNED AS A FLAT, HARD, ALL WEATHER DRIVING SURFACE CAPABLE OF SUPPORTING 40 TONS. C1.0 7 4/04/2023 **All circled are line over text.** T EV EV VAN T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 FLOOD ZONE: 1. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YEAR SPRING CREEK FLOODPLAIN. 2. DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (CURB & GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRING CREEK FLOODPLAIN LIMITS AS DELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. BENCHMARKS: PROJECT BENCHMARK: NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) SITE BENCHMARK: CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) ELEVATIONS BROUGHT TO THE SITE VIA GPS OBSERVATIONS USING THE TRIMBLE VRS NETWORK GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE NOTE: NOTES: 1.ALL POINTS REFER TO TOP BACK OF CURB UNLESS OTHERWISE NOTED. 2.TOP OF ISLAND TO BE 2" ABOVE HIGHEST ELEVATION OF SURROUNDING PAVEMENT - TYP. (SEE PETROLEUM PLANS) 3.THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100 YEAR STORM. THE LOWEST OPENING ELEVATIONS SHOWN ARE AT LEAST ONE FOOT ABOVE THE 100 YEAR STORM ELEVATION OF ADJACENT STREETS, CHANNELS, DITCHES, SWALES, OR OTHER DRAINAGE FACILITIES. MINIMUM FINISHED FLOOR ELEVATIONS ABOVE 100-YEAR WATER SURFACE IN STREETS, CHANNELS, DITCHES, SWALES, OR OTHER DRAINAGE FACILITIES, AS ILLUSTRATED BY A FINAL GRADING PLAN ARE TO BE SHOWN. 4.ON SITE STORM STRUCTURE INSERTION POINTS REFERENCE TOP OF GRATE OR SOLID COVER ELEVATION AT CENTER OF GRATE OR SOLID COVER. 5.FOR ROAD DESIGN, SEE SHEETS C4.4 & C4.5 GRADING PLANLOD LEGEND TC=TOP BACK OF CURB TS=TOP OF SLAB SW=SIDEWALK ME=MATCH EXISTING FG=FINISHED GRADE FFE=FINISHED FLOOR ELEVATION FL=FLOWLINE RIM=RIM TI= TOP OF INLET TG = TOP OF GRATE C2.1 8 4/04/2023 Does not match the required format. See written comments. **All circled are line over text.** E V SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 FLOOD ZONE: 1. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YEAR SPRING CREEK FLOODPLAIN. 2. DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (CURB & GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRING CREEK FLOODPLAIN LIMITS AS DELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. PARKING COUNT GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE NOTE: DETAIL 1 SCALE: 1"=5'DETAILED GRADING PLANLOD LIMITS OF DISTURBANCE PROPOSED PROPERTY LINE EXISTING CURB AND GUTTER GRADE BREAK COLORED CONCRETE PAVEMENT PROPOSED INTEGRAL CURB LEGEND EXISTING BOUNDARY SWALE FLOWLINE NOTES: 1.ALL POINTS REFER TO TOP BACK OF CURB UNLESS OTHERWISE NOTED. 2.ALL UNDERGROUND TANK LIDS IN DRIVE SHALL BE PLACED 1" ABOVE SURROUNDING PAVEMENT. ELEVATIONS PROVIDED AT THE UNDERGROUND TANK LIDS REFERENCE THE TOP OF PAVEMENT. 3.INSTALL CONCRETE STEPS, EACH STEP SHALL BE 12" RUN AND 7" RISE. ALL ST SPOTS ARE AT THE TOP OF THE STAIR. 4.STORM INLETS WITHIN RIGHT-OF-WAY REFERENCE POINTS MATCH TOP OF INLET BOX. DETAIL 2 SCALE: 1"=5' DETAIL 3 SCALE: 1"=5' TC=TOP BACK OF CURB TS=TOP OF SLAB SW=SIDEWALK ME=MATCH EXISTING FG=FINISHED GRADE FFE=FINISHED FLOOR ELEVATION FL=FLOWLINE RIM=RIM TI= TOP OF INLET TG = TOP OF GRATE BENCHMARKS: PROJECT BENCHMARK: NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) SITE BENCHMARK: CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) ELEVATIONS BROUGHT TO THE SITE VIA GPS OBSERVATIONS USING THE TRIMBLE VRS NETWORK C2.2 9 4/04/2023 Does not match the required format. See written comments. **All circled are line over text.** VAN 11 S LEMAY AVE2 3 T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 T EV EV E V STORM STRUCTURE TABLESTORM PIPE TABLE DOCUMENT REVISION DATE: JULY 2013SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 STORM SWER PLANEXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR LIMITS OF DISTURBANCELOD PROPOSED STORM SEWER EXISTING STORM SEWER LEGEND: EXISTING BOUNDARY PROPOSED PROPERTY LINE EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER COLORED CONCRETE PAVEMENT PROPOSED INTEGRAL CURB ROAD CENTERLINE GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE BREAK IN GRADE NOTE: FLOOD ZONE: BENCHMARKS: PROJECT BENCHMARK - NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) 1. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YEAR SPRING CREEK FLOODPLAIN. 2. DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (CURB & GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRING CREEK FLOODPLAIN LIMITS AS DELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. NOTES: 1.REFERENCE POINTS FOR STRUCTURES ARE AS FOLLOWS: ·CENTER OF LID FOR MANHOLES/CLEANOUTS ·CENTER OF INLET FACE AT TOP OF CURB FOR CURB INLETS ·CENTER OF INLET GRATE FOR GRATED INLETS ·CENTER AT INVERT OF INCOMING PIPE TO FLARED END SECTION 2.STORM SEWER PIPE LENGTHS ARE MEASURED AS FOLLOWS: ·CENTER OF MANHOLES/CLEANOUTS ·INSIDE WALL OF CURB INLET ·CENTER OF GRATE INLET ·LENGTHS LISTED ARE 2D MEASUREMENTS 3.ALL PROPOSED DRAINAGE STRUCTURES AND PIPES ON THIS SITE ARE PRIVATELY OWNED AND MAINTAINED. DRAINAGE STRUCTURES AND PIPES BECOME PUBLICLY OWNED ONCE THEY CONNECT TO THE EXISTING MANHOLE. 4.ALL PROPOSED PIPES ARE HDPE, EXCEPT AS NOTED. 5.ALL PROPOSED ONSITE INLETS ARE TO BE EQUIPPED WITH FLEXSTORM INSERTS (SEE SHEET C2.6) FLAG NOTES: INSTALL STORM SEWER PIPE; LENGTH SIZE AND SLOPE PER TABLE INSTALL NYLOPLAST 12" DRAIN BASIN w/ TRAFFIC RATED SOLID LID, SEE DETAIL SHEET C2.4 INSTALL NYLOPLAST 2X3 CURB INLET WITH HIGH FLOW GRATE AND FLEXSTORM FILTER BAGS. SEE DETAIL SHEET C2.6 INSTALL STORMTECH OUTLET STRUCTURE (SEE SHEET C2.5) CONNECT TO CANOPY DOWNSPOUT, SEE DETAIL SHEET C2.4 CONNECT TO BUILDING DOWNSPOUT, SEE ARCHITECTURAL PLANS FOR DOWNSPOUT LOCATIONS INSTALL 45° STORM SEWER BEND INSTALL 90° STORM SEWER BEND INSTALL 8" INSERTA TEE INSTALL 6" INSERTA TEE INSTALL STORMTECH INLET STRUCTURE (SEE SHEET C2.5) INSTALL PRIVATE UNDERGROUND DETENTION FACILITY (SEE SHEET C2.5) CONNECT TO EXISTING MANHOLE, GROUT AND SEAL CONNECTION INSTALL ADS 8" DURASLOT VARIABLE HEIGHT SLOTTED DRAIN. LENGTH, SLOPE, TOP OF GRATE ELEVATIONS, & INVERTS PER PLAN (SEE SHEET C2.6) INSTALL NYLOPLAST 8" DRAIN BASIN w/ LANDSCAPE DOME GRATE AND SNOUT, SEE DETAIL SHEET C2.6 INSTALL 48" MANHOLE INSTALL NYLOPLAST 15" DRAIN BASIN w/ TRAFFIC RATED SOLID LID, SEE DETAIL SHEET C2.4 100-YEAR SPRING CREEK FLOODPLAIN EXISTING STORM INLET TO BE PROTECTED IN PLACE INSTALL TRAFFIC RATED CLEANOUT INSTALL 5' CDOT TYPE R INLET (SEE SHEET C2.4) PROPOSED DRAINAGE EASEMENT PROPOSED SPILL CONTAINMENT STRUCTURE (SEE SHEET C2.6) SPILL CONTAINMENT STRUCTURE VALVE (SEE SHEET C2.6) INSTALL REINFORCED CONCRETE STORM SEWER PIPE; LENGTH SIZE AND SLOPE PER TABLE C2.3 10 4/04/2023 Spelling Does not match the required format. See written comments. SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSF SFSFSFSF SFSFSF100-YEAR SPRING CREEK FLOODPLAIN 100-YEAR SPRING CREEK FLOODPLAINLOD LODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODSHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 PH. 1 EROSION CONTROL PLANNOTE: EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR LEGEND: PROPERTY BOUNDARY EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER COLORED CONCRETE PAVEMENT PROPOSED INTEGRAL CURB PARKING COUNT GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE EXISTING LOT LINE ROAD CENTERLINE LOD LIMITS OF DISTURBANCE PROPOSED STORM SEWERSDSD EXISTING STORM SEWERSDSD INSTALL VEHICLE TRACKING PAD, PER DETAIL, SEE SHEET C2.11 INSTALL SILT FENCE, PER SILT FENCE DETAIL, SEE SHEET C2.11 SF INSTALL INLET PROTECTION, PER DETAIL, SEE SHEET C2.12 EROSION CONTROL NOTES: 1) ALL STREET, SANITARY SEWER, STORM SEWER AND WATER CONSTRUCTION SHALL CONFORM TO CITY STANDARDS AND SPECIFICATIONS CURRENT AT DATE OF EXECUTION OF THE DEVELOPMENT AGREEMENT PERTAINING TO THIS DEVELOPMENT. ANY CONSTRUCTION OCCURRING THREE YEARS AFTER THE EXECUTION OF THE DEVELOPMENT AGREEMENT SHALL REQUIRE RE-EXAMINATION OF THE PLANS BY THE DIRECTOR WHO MAY REQUIRE THAT THEY BE MADE TO CONFORM TO STANDARDS AND SPECIFICATIONS CURRENT AT THAT TIME. 2) THE TYPE, SIZE, LOCATION, AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE AS SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING UNKNOWN UNDERGROUND UTILITIES. 3) THESE PLANS HAVE BEEN REVIEWED BY THE CITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE CITY ENGINEER, OR THE CITY FOR ACCURACY OR CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT THE QUANTITIES OF THE ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE CITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. 4) MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNERS. 5) IF FILL OR DREDGED MATERIAL IS DISCHARGED INTO WATERS OF THE UNITED STATES, A USACE 404 PERMIT IS REQUIRED. 6) IF CONSTRUCTION AFFECTS ANY COLORADO HIGHWAY, A COLORADO DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY PERMIT IS REQUIRED. 7) DOWNSTREAM INLETS AT 1629 S. LEMAY AVE. MUST BE PROTECTED WITH ROCK SOCK INLET BMP'S. 8) CONTRACTOR TO ENSURE ROCK SOCK INLET BMP'S ON ARTERIAL STREETS DO NOT BLOCK VEHICLE TRAVEL LANES. 9) NO TRACKING OF DEBRIS OR SEDIMENT SHALL BE ALLOWED ON CITY STREETS, IF ANY TRACKING DOES OCCUR IT SHALL BE CLEANED IMMEDIATELY BY THE CONTRACTOR. INSTALL WATTLES, PER DETAIL, SEE SHEET C2.12 CONSTRUCTION & EROSION CONTROL SCHEDULE: 1.SILT FENCE SHALL BE INSTALLED IN THE PROPOSED LOCATIONS FOR PERIMETER CONTROL. 2.EROSION CONTROL SHALL BE INSPECTED AND MAINTAINED UNTIL FINAL GRADING, LANDSCAPING, AND STABILIZATION IS ACHIEVED. ONCE FINAL STABILIZATION HAD BEEN ACHIEVED, TEMPORARY SEDIMENT CONTROLS SHALL BE REMOVED. 3.ALL EROSION CONTROL MEASURES TO BE INSTALLED PER DETAILS AND SPECIFICATIONS SHOWN WITHIN THESE PLANS AND THE STORMWATER MANAGEMENT PLAN (SWMP) REPORT. 4.ALL DISTURBED AREAS NOT COVERED BY PAVEMENT OR SEED/MULCH SHALL BE PERMANENTLY LANDSCAPED ACCORDING TO THE LANDSCAPE PLAN. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THIS PLAN THROUGHOUT CONSTRUCTION AND PERFORMING INSPECTIONS/MAINTENANCE PER THE CDPHE PERMIT, UNTIL SUCH TIME THE PERMIT IS CLOSED. CONSTRUCTION SEQUENCE CHART: SITE INFORMATION TOTAL DISTURBED AREA 1.35 AC TOTAL ON-SITE DISTURBED AREA 0.92 AC TOTAL OFF-SITE DISTURBED AREA 0.43 AC TOTAL STAGING/STORAGE AREA STABILIZED STAGING AREA: 2,910.93 SF STOCKPILE MANAGEMENT AREA: 1,020.13 SF ESTIMATED % EXPOSED 100% ESTIMATED % VEGETATIVE 30% SOIL INFORMATION HYDROLOGIC SOIL GROUP C: NUNN CLAY AND SATANA LOAM WITH SHORT PASTURED/LAWN AND GRASSES WITH SHRUBS AND TREES GOUNDWATER DEPTH HIGHEST RECORDED DEPTH FROM EXISTING GRADE: 7.1' LOWEST RECORDED DEPTH FROM EXISTING GRADE: 13.7 NUMBER OF PHASES 3 PHASES TOTAL VOLUME OF IMPORT/EXPORT 1,692.5 CUBIC YARDS OF FILL STEEPEST SLOPE 4:1 RECEIVING WATERS SPRING CREEK 100 YEAR RUNOFF COEFFICIENT (AFTER CONSTRUCTION)C2 = 0.77 C100 = 0.96 SURFACE COVERAGE (AFTER CONSTRUCTION) PAVEMENT AREA = 40,040.47 SF ROOF AREA = 6,658 SF LANDSCAPE AREA = 11,988 SF (REFER TO LANDSCAPE PLAN BREAKDOWN OF SOD/SEED) OWNER/DEVELOPER/APPLICANT: ENGINEER: THE OWNER WILL COMPLY WITH THE REQUIREMENTS OF THE EROSION AND STORMWATER QUALITY CONTROL PLAN INCLUDING TEMPORARY BMP INSPECTION REQUIREMENTS AND FINAL STABILIZATION REQUIREMENTS. I ACKNOWLEDGE THE RESPONSIBILITY TO DETERMINE WHETHER THE CONSTRUCTION ACTIVITIES ON THESE PLANS REQUIRE COLORADO DISCHARGE PERMIT SYSTEM (CDPS) PERMITTING FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. DEVELOPER/OWNER SIGNATURE: ______________________________________ NAME OF DEVELOPER/OWNER: RYAN HALDER DATE: _____________ DBA: KUM & GO, L.C. PHONE: 515.457.6232 TITLE: SITE DEVELOPMENT MANAGER EMAIL: RYAN.HALDER@KUMANDGO.COM ADDRESS: 1459 GRAND AVEUNE, DES MOINES, IA 50309 FAX: 515.226.1595 DEVELOPER/OWNER'S STATEMENT THIS EROSION AND STORMWATER QUALITY CONTROL/GRADING PLAN WAS PREPARED UNDER MY DIRECTION AND SUPERVISION AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. IF SUCH WORK IS PERFORMED IN ACCORDANCE WITH THE GRADING AND EROSION CONTROL PLAN, THE WORK WILL NOT BECOME A HAZARD TO LIFE AND LIMB, ENDANGER PROPERTY, OR ADVERSELY AFFECT THE SAFETY, USE, OR STABILITY OF A PUBLIC WAY, DRAINAGE CHANNEL, OR OTHER PROPERTY. SIGNATURE: _________________________________ DATE: ________ PRINTED NAME: ______________________________ ENGINEER'S STATEMENT SWMP ADMINISTRATOR OLSSON, INC. 1880 FALL RIVER DRIVE, SUITE 200 LOVELAND, CO 80538 CONTACT: ERICA MORTON PH:(970) 635.3700 E:EMORTON@OLSSON.COM KUM & GO 1904, L.L.C. 1459 GRAND AVENUE DES MOINES, IA 50309 CONTACT: DAN GARNEAU PH: (515)226.0128 E: DAN.GARNEAU@KUMANDGO.COM SAME INFO AS OWNER/DEVELOPER/APPLICANT BASIS OF BEARINGS: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. BENCHMARKS: PROJECT BENCHMARK: NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) SITE BENCHMARK: CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) ELEVATIONS BROUGHT TO THE SITE VIA GPS OBSERVATIONS USING THE TRIMBLE VRS NETWORK C2.7 14 4/04/2023 **All circled are line over text.** Does not match the required format. See written comments. T EV EV E V SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSF SFSFSFSF SFSFSFSF SF SF SF S F SFSF100-YEAR SPRING CREEK FLOODPLAIN 100-YEAR SPRING CREEK FLOODPLAINLOD LODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODSHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 PH. 2 EROSION CONTROL PLANNOTE: EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR LEGEND: PROPERTY BOUNDARY EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER COLORED CONCRETE PAVEMENT PROPOSED INTEGRAL CURB PARKING COUNT GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE EXISTING LOT LINE ROAD CENTERLINE LOD LIMITS OF DISTURBANCE PROPOSED STORM SEWERSDSD EXISTING STORM SEWERSDSD INSTALL VEHICLE TRACKING PAD, PER DETAIL, SEE SHEET C2.11 INSTALL SILT FENCE, PER SILT FENCE DETAIL, SEE SHEET C2.11 SF INSTALL 35' x 100' STABILIZED STAGING AREA PER DETAIL, SEE SHEET C2.11 INSTALL CONCRETE WASHOUT AREA PER DETAIL, SEE SHEET C2.12 INSTALL INLET PROTECTION, PER DETAIL, SEE SHEET C2.12 EROSION CONTROL NOTES: 1) ALL STREET, SANITARY SEWER, STORM SEWER AND WATER CONSTRUCTION SHALL CONFORM TO CITY STANDARDS AND SPECIFICATIONS CURRENT AT DATE OF EXECUTION OF THE DEVELOPMENT AGREEMENT PERTAINING TO THIS DEVELOPMENT. ANY CONSTRUCTION OCCURRING THREE YEARS AFTER THE EXECUTION OF THE DEVELOPMENT AGREEMENT SHALL REQUIRE RE-EXAMINATION OF THE PLANS BY THE DIRECTOR WHO MAY REQUIRE THAT THEY BE MADE TO CONFORM TO STANDARDS AND SPECIFICATIONS CURRENT AT THAT TIME. 2) THE TYPE, SIZE, LOCATION, AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE AS SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING UNKNOWN UNDERGROUND UTILITIES. 3) THESE PLANS HAVE BEEN REVIEWED BY THE CITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE CITY ENGINEER, OR THE CITY FOR ACCURACY OR CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT THE QUANTITIES OF THE ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE CITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. 4) MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNERS. 5) IF FILL OR DREDGED MATERIAL IS DISCHARGED INTO WATERS OF THE UNITED STATES, A USACE 404 PERMIT IS REQUIRED. 6) IF CONSTRUCTION AFFECTS ANY COLORADO HIGHWAY, A COLORADO DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY PERMIT IS REQUIRED. 7) DOWNSTREAM INLETS AT 1629 S. LEMAY AVE. MUST BE PROTECTED WITH ROCK SOCK INLET BMP'S. 8) PROVIDE TEMPORARY SEEDING AND MULCHING IN ALL AREAS UNTIL PHASES 3 AND 4 ARE CONSTRUCTED. INSTALL WATTLES, PER DETAIL, SEE SHEET C2.12 INSTALL INLET PROTECTION, PER DETAIL, SEE SHEET C2.12 CONSTRUCTION & EROSION CONTROL SCHEDULE: 1.SILT FENCE SHALL BE INSTALLED IN THE PROPOSED LOCATIONS FOR PERIMETER CONTROL. 2.EROSION CONTROL SHALL BE INSPECTED AND MAINTAINED UNTIL FINAL GRADING, LANDSCAPING, AND STABILIZATION IS ACHIEVED. ONCE FINAL STABILIZATION HAD BEEN ACHIEVED, TEMPORARY SEDIMENT CONTROLS SHALL BE REMOVED. 3.ALL EROSION CONTROL MEASURES TO BE INSTALLED PER DETAILS AND SPECIFICATIONS SHOWN WITHIN THESE PLANS AND THE STORMWATER MANAGEMENT PLAN (SWMP) REPORT. 4.ALL DISTURBED AREAS NOT COVERED BY PAVEMENT OR SEED/MULCH SHALL BE PERMANENTLY LANDSCAPED ACCORDING TO THE LANDSCAPE PLAN. 5.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THIS PLAN THROUGHOUT CONSTRUCTION AND PERFORMING INSPECTIONS/MAINTENANCE PER THE CDPHE PERMIT, UNTIL SUCH TIME THE PERMIT IS CLOSED. INSTALL TEMPORARY SEED AND MULCH INSTALL STOCKPILE MANAGEMENT MEASURES, PER SHEET C2.11 CONSTRUCTION SEQUENCE CHART: SITE INFORMATION TOTAL DISTURBED AREA 1.35 AC TOTAL ON-SITE DISTURBED AREA 0.92 AC TOTAL OFF-SITE DISTURBED AREA 0.43 AC TOTAL STAGING/STORAGE AREA STABILIZED STAGING AREA: 2,910.93 SF STOCKPILE MANAGEMENT AREA: 1,020.13 SF ESTIMATED % EXPOSED 100% ESTIMATED % VEGETATIVE 30% SOIL INFORMATION HYDROLOGIC SOIL GROUP C: NUNN CLAY AND SATANA LOAM WITH SHORT PASTURED/LAWN AND GRASSES WITH SHRUBS AND TREES GOUNDWATER DEPTH HIGHEST RECORDED DEPTH FROM EXISTING GRADE: 7.1' LOWEST RECORDED DEPTH FROM EXISTING GRADE: 13.7' NUMBER OF PHASES 3 PHASES TOTAL VOLUME OF IMPORT/EXPORT 1,692.5 CUBIC YARDS OF FILL STEEPEST SLOPE 4:1 RECEIVING WATERS SPRING CREEK 100 YEAR RUNOFF COEFFICIENT (AFTER CONSTRUCTION)C2 = 0.77 C100 = 0.96 SURFACE COVERAGE (AFTER CONSTRUCTION) PAVEMENT AREA = 40,040.47 SF ROOF AREA = 6,658 SF LANDSCAPE AREA = 11,988 SF (REFER TO LANDSCAPE PLAN BREAKDOWN OF SOD/SEED) OWNER/DEVELOPER/APPLICANT: ENGINEER: THE OWNER WILL COMPLY WITH THE REQUIREMENTS OF THE EROSION AND STORMWATER QUALITY CONTROL PLAN INCLUDING TEMPORARY BMP INSPECTION REQUIREMENTS AND FINAL STABILIZATION REQUIREMENTS. I ACKNOWLEDGE THE RESPONSIBILITY TO DETERMINE WHETHER THE CONSTRUCTION ACTIVITIES ON THESE PLANS REQUIRE COLORADO DISCHARGE PERMIT SYSTEM (CDPS) PERMITTING FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. DEVELOPER/OWNER SIGNATURE: ______________________________________ NAME OF DEVELOPER/OWNER: RYAN HALDER DATE: _____________ DBA: KUM & GO, L.C. PHONE: 515.457.6232 TITLE: SITE DEVELOPMENT MANAGER EMAIL: RYAN.HALDER@KUMANDGO.COM ADDRESS: 1459 GRAND AVEUNE, DES MOINES, IA 50309 FAX: 515.226.1595 DEVELOPER/OWNER'S STATEMENT THIS EROSION AND STORMWATER QUALITY CONTROL/GRADING PLAN WAS PREPARED UNDER MY DIRECTION AND SUPERVISION AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. IF SUCH WORK IS PERFORMED IN ACCORDANCE WITH THE GRADING AND EROSION CONTROL PLAN, THE WORK WILL NOT BECOME A HAZARD TO LIFE AND LIMB, ENDANGER PROPERTY, OR ADVERSELY AFFECT THE SAFETY, USE, OR STABILITY OF A PUBLIC WAY, DRAINAGE CHANNEL, OR OTHER PROPERTY. SIGNATURE: _________________________________ DATE: ________ PRINTED NAME: ______________________________ ENGINEER'S STATEMENT SWMP ADMINISTRATOR OLSSON, INC. 1880 FALL RIVER DRIVE, SUITE 200 LOVELAND, CO 80538 CONTACT: ERICA MORTON PH:(970) 635.3700 E:EMORTON@OLSSON.COM KUM & GO 1904, L.L.C. 1459 GRAND AVENUE DES MOINES, IA 50309 CONTACT: DAN GARNEAU PH: (515)226.0128 E: DAN.GARNEAU@KUMANDGO.COM SAME INFO AS OWNER/DEVELOPER/APPLICANT BASIS OF BEARINGS: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. BENCHMARKS: PROJECT BENCHMARK: NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) SITE BENCHMARK: CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) ELEVATIONS BROUGHT TO THE SITE VIA GPS OBSERVATIONS USING THE TRIMBLE VRS NETWORK C2.8 15 4/04/2023 **All circled are line over text.** Does not match the required format. See written comments. VAN 11 E PROSPECT RD S LEMAY AVE2 3 T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 T EV EV E V SFSFSF100-YEAR SPRING CREEK FLOODPLAIN UNDERGROUND WATER QUALITY TREATMENT SYSTEM (STORM TECH) 100-YEAR SPRING CREEK FLOODPLAINLOD LODLOD LODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLODSHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 PH. 3 & 4 EROSION CONTROL PLANNOTE: EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED MINOR CONTOUR LEGEND: PROPERTY BOUNDARY EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER COLORED CONCRETE PAVEMENT PROPOSED INTEGRAL CURB PARKING COUNT GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE VEGETATION SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE EXISTING LOT LINE ROAD CENTERLINE LOD LIMITS OF DISTURBANCE PROPOSED STORM SEWERSDSD EXISTING STORM SEWERSDSD OWNER/DEVELOPER/APPLICANT: ENGINEER: THE OWNER WILL COMPLY WITH THE REQUIREMENTS OF THE EROSION AND STORMWATER QUALITY CONTROL PLAN INCLUDING TEMPORARY BMP INSPECTION REQUIREMENTS AND FINAL STABILIZATION REQUIREMENTS. I ACKNOWLEDGE THE RESPONSIBILITY TO DETERMINE WHETHER THE CONSTRUCTION ACTIVITIES ON THESE PLANS REQUIRE COLORADO DISCHARGE PERMIT SYSTEM (CDPS) PERMITTING FOR STORMWATER DISCHARGES ASSOCIATED WITH CONSTRUCTION ACTIVITY. DEVELOPER/OWNER SIGNATURE: ______________________________________ NAME OF DEVELOPER/OWNER: RYAN HALDER DATE: _____________ DBA: KUM & GO, L.C. PHONE: 515.457.6232 TITLE: SITE DEVELOPMENT MANAGER EMAIL: RYAN.HALDER@KUMANDGO.COM ADDRESS: 1459 GRAND AVEUNE, DES MOINES, IA 50309 FAX: 515.226.1595 DEVELOPER/OWNER'S STATEMENT THIS EROSION AND STORMWATER QUALITY CONTROL/GRADING PLAN WAS PREPARED UNDER MY DIRECTION AND SUPERVISION AND IS CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. IF SUCH WORK IS PERFORMED IN ACCORDANCE WITH THE GRADING AND EROSION CONTROL PLAN, THE WORK WILL NOT BECOME A HAZARD TO LIFE AND LIMB, ENDANGER PROPERTY, OR ADVERSELY AFFECT THE SAFETY, USE, OR STABILITY OF A PUBLIC WAY, DRAINAGE CHANNEL, OR OTHER PROPERTY. SIGNATURE: _________________________________ DATE: ________ PRINTED NAME: ______________________________ EROSION CONTROL NOTES: ENGINEER'S STATEMENT SWMP ADMINISTRATOR OLSSON, INC. 1880 FALL RIVER DRIVE, SUITE 200 LOVELAND, CO 80538 CONTACT: ERICA MORTON PH:(970) 635.3700 E:EMORTON@OLSSON.COM KUM & GO 1904, L.L.C. 1459 GRAND AVENUE DES MOINES, IA 50309 CONTACT: DAN GARNEAU PH: (515)226.0128 E: DAN.GARNEAU@KUMANDGO.COM SAME INFO AS OWNER/DEVELOPER/APPLICANT CONSTRUCTION & EROSION CONTROL SCHEDULE: BASIS OF BEARINGS: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. 1.SITE GRADING SHALL BE COMPLETED AND FOLLOWED UP BY UTILITY AND PAVING CONSTRUCTION ALONG WITH REDISTRIBUTION OF STRIPPINGS. IF UTILITY AND PAVING CONSTRUCTION IS DELAYED, TEMPORARY COVER CROP SHALL BE SEEDED. 2.ONCE STORM SEWER IS FINISHED, INLET PROTECTION SHALL BE INSTALLED. 3.EROSION CONTROL SHALL BE INSPECTED AND MAINTAINED UNTIL FINAL GRADING, LANDSCAPING, AND STABILIZATION IS ACHIEVED. ONCE FINAL STABILIZATION HAD BEEN ACHIEVED, TEMPORARY SEDIMENT CONTROLS SHALL BE REMOVED. 4.ALL EROSION CONTROL MEASURES TO BE INSTALLED PER DETAILS AND SPECIFICATIONS SHOWN WITHIN THESE PLANS AND THE STORMWATER MANAGEMENT PLAN (SWMP) REPORT. 5.ALL DISTURBED AREAS NOT COVERED BY PAVEMENT OR SEED/MULCH SHALL BE PERMANENTLY LANDSCAPED ACCORDING TO THE LANDSCAPE PLAN. 6.CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THIS PLAN THROUGHOUT CONSTRUCTION AND PERFORMING INSPECTIONS/MAINTENANCE PER THE CDPHE PERMIT, UNTIL SUCH TIME THE PERMIT IS CLOSED. 1) ALL STREET, SANITARY SEWER, STORM SEWER AND WATER CONSTRUCTION SHALL CONFORM TO CITY STANDARDS AND SPECIFICATIONS CURRENT AT DATE OF EXECUTION OF THE DEVELOPMENT AGREEMENT PERTAINING TO THIS DEVELOPMENT. ANY CONSTRUCTION OCCURRING THREE YEARS AFTER THE EXECUTION OF THE DEVELOPMENT AGREEMENT SHALL REQUIRE RE-EXAMINATION OF THE PLANS BY THE DIRECTOR WHO MAY REQUIRE THAT THEY BE MADE TO CONFORM TO STANDARDS AND SPECIFICATIONS CURRENT AT THAT TIME. 2) THE TYPE, SIZE, LOCATION, AND NUMBER OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE AS SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE AND LOCATION OF ALL UNDERGROUND UTILITIES ALONG THE ROUTE OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING UNKNOWN UNDERGROUND UTILITIES. 3) THESE PLANS HAVE BEEN REVIEWED BY THE CITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE REVIEWING DEPARTMENT, THE CITY ENGINEER, OR THE CITY FOR ACCURACY OR CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT THE QUANTITIES OF THE ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE CITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. 4) MAINTENANCE OF ONSITE DRAINAGE FACILITIES SHALL BE THE RESPONSIBILITY OF THE PROPERTY OWNERS. 5) IF FILL OR DREDGED MATERIAL IS DISCHARGED INTO WATERS OF THE UNITED STATES, A USACE 404 PERMIT IS REQUIRED. 6) IF CONSTRUCTION AFFECTS ANY COLORADO HIGHWAY, A COLORADO DEPARTMENT OF TRANSPORTATION RIGHT-OF-WAY PERMIT IS REQUIRED. 7) DOWNSTREAM INLETS AT 1629 S. LEMAY AVE. MUST BE PROTECTED WITH ROCK SOCK INLET BMP'S. 8) UNDERGROUND WATER QUALITY TREATMENT SHALL BE DONE AS PART OF THE LAST SEQUENCE IN CONSTRUCTION TO MINIMIZE SEDIMENTATION POTENTIAL. 9) FINAL SITE STABILIZATION SHALL BE DONE IN ACCORDANCE WITH THE APPROVED LANDSCAPE PLAN FOR THIS PROPERTY. FINAL STABILIZATION TO BE ROCK MULCH AND TURF GRASS, INSTALLED PER LANDSCAPING SPECIFICATIONS. SEE SHEET L1.1 CONSTRUCTION SEQUENCE CHART: SITE INFORMATION TOTAL DISTURBED AREA 1.35 AC TOTAL ON-SITE DISTURBED AREA 0.92 AC TOTAL OFF-SITE DISTURBED AREA 0.43 AC TOTAL STAGING/STORAGE AREA STABILIZED STAGING AREA: 2,910.93 SF STOCKPILE MANAGEMENT AREA: 1,020.13 SF ESTIMATED % EXPOSED 100% ESTIMATED % VEGETATIVE 30% SOIL INFORMATION HYDROLOGIC SOIL GROUP C: NUNN CLAY AND SATANA LOAM WITH SHORT PASTURED/LAWN AND GRASSES WITH SHRUBS AND TREES GOUNDWATER DEPTH HIGHEST RECORDED DEPTH FROM EXISTING GRADE: 7.1' LOWEST RECORDED DEPTH FROM EXISTING GRADE: 13.7' NUMBER OF PHASES 3 PHASES TOTAL VOLUME OF IMPORT/EXPORT 1,692.5 CUBIC YARDS OF FILL STEEPEST SLOPE 4:1 RECEIVING WATERS SPRING CREEK 100 YEAR RUNOFF COEFFICIENT (AFTER CONSTRUCTION)C2 = 0.77 C100 = 0.96 SURFACE COVERAGE (AFTER CONSTRUCTION) PAVEMENT AREA = 40,040.47 SF ROOF AREA = 6,658 SF LANDSCAPE AREA = 11,988 SF (REFER TO LANDSCAPE PLAN BREAKDOWN OF SOD/SEED) BENCHMARKS: PROJECT BENCHMARK: NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) SITE BENCHMARK: CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) ELEVATIONS BROUGHT TO THE SITE VIA GPS OBSERVATIONS USING THE TRIMBLE VRS NETWORK C2.9 16 4/04/2023 Does not match the required format. See written comments. **All circled are line over text.** VAN E PROSPECT RD S LEMAY AVET SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 T EV EV E V 1.PROPOSED TRANSFORMER PAD AREA TO BE EXCAVATED, PREPARED AND POLE FOR C/T AND METER SET BY CONTRACTOR, PAD & TRANSFORMER TO BE INSTALLED BY LIGHT & POWER. CONTRACTOR SHALL TRENCH & INSTALL CONDUIT BETWEEN POINT OF CONNECTION & TRANSFORMER & INSTALL POLE FOR C/T AND METER, ELECTRICAL CONTRACTOR SHALL PULL CONDUCTORS. 2.ALL PROPOSED SITE LIGHTING WILL CONSIST OF FULL CUT-OFF DESIGN, SEE MEP PLANS FOR SITE LIGHTING ELECTRICAL PLAN AND POLE BASE DETAIL. DISTANCE FROM CENTER OF POLE TO BACK OF CURB = 4' UNLESS NOTED OTHERWISE. 3.CONTRACTOR SHALL MAINTAIN MINIMUM 18" VERTICAL SEPARATION AT ALL UTILITY CROSSINGS, UNLESS NOTED OTHERWISE. 4.ALL PROPOSED DOMESTIC WATER SERVICE PIPING SHALL BE TYPE K COPPER UNLESS NOTED OTHERWISE. 5.ALL PROPOSED SANITARY SEWER SERVICE PIPING SHALL BE PVC SDR35 UNLESS NOTED OTHERWISE. 6.ALL PROPOSED DRY UTILITY CONDUIT PIPING SHALL BE PVC SCH40 UNLESS NOTED OTHERWISE. 7.PROPOSED 1000 GALLON GREASE INTERCEPTOR WITH SAMPLE PORT, WATERTIGHT TRAFFIC RATED LIDS, AND 2-WAY 4" CLEANOUTS AT INLET AND OUTLET OF INTERCEPTOR, SEE SHEET C3.2 FOR DETAIL. 8.ALL PROPOSED SANITARY SERVICE CLEANOUTS (CO) SHALL HAVE WATER TIGHT LIDS. 9.CONTRACTOR SHALL COORDINATE FLOW TESTING OF PROPOSED FIRE HYDRANT WITH CITY OF FORT COLLINS PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY. 10.CONTRACTOR SHALL COORDINATE INSTALLATION OF PRIMARY POWER WITH LIGHT & POWER UPON CONSTRUCTION KICKOFF. 11.CONTRACTOR TO PATCH & REPLACE ASPHALT IN-KIND FOR ALL UTILITY STREET CUTS. 12.CONTRACTOR TO VERIFY EXISTING INVERT OF EXISTING 6" STEEL SANITARY SERVICE & REPORT TO ENGINEER WITH ANY DISCREPANCY IN DESIGN TIE ELEVATION. 13.CITY OF FORT COLLINS POWER DEPARTMENT WILL SET A NEW VAULT ON THE SE CORNER OF LEMAY & PROSPECT AND WILL DIRECTIONAL BORE A CONDUIT AND WIRE UNDER LEMAY AND WILL SET TRANSFORMER. PRIVATE UTILITY NOTES: NOTE: CO CLEANOUT SS SANITARY SEWER BOP BOTTOM OF PIPE TOP TOP OF PIPE UGE UNDERGROUND ELECTRICEXISTING WATER LINE EXISTING SANITARY SEWER EXISTING UNDERGROUND POWER EXISTING STORM SEWER EXISTING GAS LINE EXISTING OVERHEAD POWER EXISTING FIBER OPTIC LINE PROPOSED BOUNDARY EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED INTEGRAL CURB LEGEND GAS METER WATER VALVE CONTROL POINT FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE STORM SEWER STRUCTURE SIGN GREASE INTERCEPTOR LID PROPOSED BOLLARD PROPOSED TRANSFORMER GUY WIRE POWER POLE UTILITY SERVICE PLANSHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) BENCHMARKS: C3.1 20 CROSSING TABLE #1 PRO ELECTRIC BOP = 4948.15 PRO STORM TOP =4946.58 CLEAR = 1'-7" #2 PRO FIBER BOP = 4946.80 PRO ELECTRIC TOP = 4946.30 CLEAR = 0'-6" #3 PRO ELECTRIC BOP = 4947.60 PRO STORM TOP = 4946.91 CLEAR = 0'-8" #4 PRO ELECTRIC BOP = 4946.10 PRO STORM TOP = 4944.78 CLEAR = 1'-4" #5 PRO SANITARY BOP = 4947.31 PRO IRRIGATION TOP = 4945.81 CLEAR = 1'-5" #6 PRO SANITARY BOP = 4946.96 PRO WATER TOP = 4945.46 CLEAR = 1'-5" #7 PRO ELECTRIC BOP = 4947.17 PRO IRRIGATION TOP =4945.17 CLEAR = 2'-0" #8 PRO ELECTRIC BOP = 4947.22 PRO WATER TOP = 4945.22 CLEAR = 2'-0" #9 PRO ELECTRIC BOP = 4946.85 PRO SANITARY TOP = 4941.77 CLEAR = 5'-1" #10 EX STORM BOP = 4942.57 PRO SEWER TOP = 4941.44 CLEAR = 1'-2" #11 EX GAS BOP = 4945.98 PRO SANITARY TOP = 4941.37 CLEAR = 4'-7" #12 EX WATER BOP = 4944.23 PRO SANITARY TOP = 4941.24 CLEAR = 3'-0" *DRY UTILITIES WITHOUT BURY DEPTH ARE ASSUMED AT AN APPROX. 3' DEPTH *EXISTING WATER UTILITIES WITHOUT BURY DEPTH ASSUMED AT A DEPTH OF 5'-6" *CAUTION CROSSING: UNKNOWN DEPTH OF UTILITY, MAINTAIN 1'-6" VERTICAL SEPARATION MINIMUM *FOR CROSSINGS 11 & 12 EXISTING GRADE ELEVATION IS ASSUMED BASED ON GUTTER ELEVATION AND 2% STANDARD ROADWAY CROSS SLOPE 4/04/2023 Does not match the required format. See written comments. VAN 11 E PROSPECT RD S LEMAY AVE2 3 T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 4945 4950 4955 4960 4945 4950 4955 4960 -0+25 0+00 1+00 2+00 3+00 4+00 5+00 5+75 -0.52% -0.74% -2.01% -0.63%-0.58%-0.50% -1.22%-0.74%0.04% -0.70%1.23% -0.81% BASIS OF BEARING: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO.FLOWLINE PLAN & PROFILESHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 C4.4 26 4/04/2023 **All circled are line over text.** VAN 11 S LEMAY AVE2 3 T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1DOCUMENT REVISION DATE: JULY 2013ADA PLANPROPERTY BOUNDARY EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED INTEGRAL CURB ADA PATH OF TRAVEL AT 5'-0" WID, 2% MAX. CROSS SLOPE; 5% MAX. RUNNING SLOPE. AREAS WILL BE FIELD VERIFIED BY OWNER. AREAS OUT OF COMPLIANCE WILL BE REMOVED AND REPLACED BY THE CONTRACTOR AT NO COST TO KUM & GO. (SEE PAVING PLAN FOR DETAILS.) ADA LANDING AREA, 2% MAX. SLOPE IN ALL DIRECTIONS. AREAS WILL BE FIELD VERIFIED BY OWNER. AREAS OUT OF COMPLIANCE WILL BE REMOVED AND REPLACED BY THE CONTRACTOR AT NO COST TO KUM & GO. (SEE PAVING PLAN FOR DETAILS.) ADA RAMPS, AREA INDICATES A 2% MAX. CROSS SLOPE AND 1:12 MAX. RUNNING SLOPE. RAMP SIDE SLOPES SHALL NOT EXCEED 1:10 MAX. FOR BUILDING SIDEWALK RAMPS. AREAS WILL BE FIELD VERIFIED BY OWNER. AREAS OUT OF COMPLIANCE WILL BE REMOVED AND REPLACED BY THE CONTRACTOR AT NO EXPENSE TO KUM &GO. (SEE PAVING PLAN FOR DETAILS.) 5' X 5' LANDING AREA, 1% MAX. 5' X 5' RAMP LANDING AREA, 2% MAX. GENERAL NOTES: 1.CHANGES TO THE ADA COMPLIANCE PLAN MUST FOLLOW THE RFI PROCESS PRIOR TO FIELD CHANGES INCLUDING CHANGES REQUESTED BY GOVERNING AUTHORITIES. 2.REFER TO GRADING PLAN FOR SPOT ELEVATIONS. CLARIFICATION OR REQUEST FOR ADDITIONAL INFORMATION MUST FOLLOW THE RFI PROCESS. 3.SIDEWALK REPLACEMENT MUST MEET THE CURRENT FEDERAL ADA REQUIREMENTS. 4.SEALANT WITHIN JOINTS MUST NOT EXCEED 1 4" MAX. DEPTH OF PROJECTION FOR INSTALLATION IN ADA ROUTES. SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 C4.6 28 4/04/2023 **All circled are line over text.** DOCUMENT REVISION DATE: JULY 2013PAVING DETAILSNOTES: 1. ALL ACCESSIBLE STALL PAVEMENT MARKINGS SHALL BE 4" WIDE YELLOW STRIPES. 2. ACCESSIBLE AISLE SHALL BE 8' WIDE FOR VANS. 3. ACCESSIBLE PARKING AREA SURFACE SHALL NOT EXCEED 2% SLOPE IN ANY DIRECTION. 4. A SIGN MUST MARK ACCESSIBLE PARKING. THE SYMBOL ON THE PAVEMENT IS NOT ADEQUATE. 8'8'9' PROPOSED ADA VAN ACCESSIBLE STALL SYMBOL PROPOSED ADA STALL BOLLARD-MOUNTED ADA SIGN 1. 5% 2. 0% M A X . 1. 5% 2'-6" O.C. YELLOW STRIPING, 45° CROSS HATCHMA X . VAN 19 ' NOTE: THIS ILLUSTRATION IS NOT TO SCALE AND IS INTENDED TO REPRESENT A CONCEPTUAL IMAGE OF THE BUILDING. 2. 5 'MA X . ( A N Y D I R E C T I O N ) 8'8'9' 8'4.5' 8' 4. 5 ' SOLID BLUE BACKGROUND 3" WHITE PAINT 4" WHITE BORDER SLOPE GUTTER TO MATCH SLOPE OF ADJACENT PAVEMENT 6"6"R1/4" R2" R2" REF. PAVEMENT DETAILS FOR THICKNESS NOTE: START PLACEMENT OF BOLLARDS BASED OFF CENTERLINE OF MAIN ENTRY. VAN 2.5' 5' TYP CL PLAN VIEW ISOLATION JOINT SAW CUT CONSTRUCTION JOINT 40' TYP. 30' MIN.ENTRANCE THROAT DEPTHPROPOSED APPROACH 3' (UNLESS OTHERWISE NOTED ON PLANS) HEAVY BROOM FINISHED CONCRETE (SEE DETAIL L - SHEET C4.6) CURB R2' R2' EXTEND 1' BEYOND CURB RETURN EDGE OF ROLLOVER TO BE FLUSH WITH EDGES OF SIDEWALK 3' TRANSITION (TYP) ROLLOVER CURB SLOPE GUTTER TO MATCH SLOPE OF ADJACENT PAVEMENT R9" R4" 3"11" REF. PAVEMENT DETAILS FOR THICKNESS 6"3' UNLESS NOTED OTHERWISE 4" INTEGRAL COLORED CONCRETE 4" MIN ASTM D448 #57 STONE OR APPROVED ALTERNATIVE PROPOSED SUBGRADE CONSTRUCTION JOINT WITH 12" #4 DOWELS @ 24" O.C. PER SPECIFICATIONS DEPTH TO MATCH THAT OF ADJACENT CONCRETE SECTION JOINT SEALING MATERIAL PAVING DETAILSSHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 C4.8 30 4/04/2023 **All circled are line over text.** E V E PROSPECT RD S LEMAY AVEE PROSPECT RDS LEMAY AVEDOCUMENT REVISION DATE: JULY 2013FLAG NOTES: EXISTING TRAFFIC SIGNAL AND MAST ARM EXISTING UNDERGROUND TRAFFIC SIGNAL CABINET ADA RAMPS EXISTING ABOVE GROUND TRAFFIC SIGNAL CABINET EXISTING STORM STRUCTURE EXISTING STORM LINE EXISTING WATER LINE EXISTING UNDERGROUND ELECTRIC LINE EXISTING FIBER OPTIC LINE EXISTING GAS LINE PROPOSED PEDESTRIAN CROSSING BUTTON PROPOSED TRAFFIC SIGNAL AND MAST ARM PROPOSED UNDERGROUND TRAFFIC SIGNAL CABINET PROPOSED UNDERGROUND ELECTRIC LINE, COORDINATE WITH LOCAL PROVIDER, LENGTH PER PLAN EXISTING PROPERTY LINE SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 TRAFFIC SIGNAL PLANPROPERTY BOUNDARY EXISTING CURB AND GUTTER PROPOSED CURB AND GUTTER PROPOSED INTEGRAL CURB GAS METER WATER VALVE FIRE HYDRANT LIGHT POLE TRAFFIC SIGNAL ARM FIBER OPTIC MANHOLE SANITARY SEWER STRUCTURE SIGN POWER POLE LEGEND EXISTING WATER LINE EXISTING SANITARY SEWER EXISTING UNDERGROUND POWER EXISTING STORM SEWER EXISTING GAS LINE EXISTING OVERHEAD POWER EXISTING FIBER OPTIC LINE EXISTING UNDERGROUND TRAFFIC BOX EXISTING ABOVE GROUND TRAFFIC CABINET NOTE: 1.ALL EXISTING TRAFFIC SIGNALS ARE TO REMAIN AND ARE TO BE PROTECTED IN PLACE. C5.0 33 4/04/2023 **All circled are line over text.** T EV EV E V VAN 11 S LEMAY AVE2 3 T SQUARE FOOTAGE: 4,066 BISTRO-RP-2021V1 3 - AT 2 - SS 2 - AT 2 - GD 3 - SS 2 - QS 1 - UA 3 - PP 489 sf - TL 870 sf - TL 591 sf - TL 1,200 sf - TL 169 sf - TL 6,392 sf - RM 86 sf - RM 284 sf - RM 873 sf - RM 778 sf - RM 4 - EC 3 - KF 3 - DK 6 - LP 4 - CJ 13 - KF 3 - CF 7 - EC 6 - RW 3 - LP 1 - PM 2 - CJ 6 - LP 3 - LP11 - LV 2 - PM3 - CF 12 - KF 4 - EC 2 - SMO 2 - PM 5 - SV 3 - EC 3 - DK 6 - LP 19 - KF 2 - CF 4 - SMO 5 - CJ 9 - CJ 8 - CB 3 - SMO 4 - LP 8 - KF 179 sf - RM 6 - CJ 3 - CF4 - KF PLANT SCHEDULE DOCUMENT REVISION DATE: JULY 2013LEGEND L1.1 FINAL LANDSCAPE PLANTREE REMOVAL NOTE: NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. THE SURVEY SHALL BE SENT TO THE CITY ENVIRONMENTAL PLANNER. IF ACTIVE NESTS ARE FOUND, THE CITY WILL COORDINATE WITH RELEVANT STATE AND FEDERAL REPRESENTATIVES TO DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. LANDSCAPE-UTILITY SEPARATION: NO TREES SHALL BE PLANTED WITHIN 10 FEET OF WATER AND SEWER MAINS OR WITHIN 6 FEET OF SERVICE LINES. NO SHRUBS SHALL BE PLANTED WITHIN 4 FEET OF WATER AND SEWER MAINS OR SERVICE LINES. 35 A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. NOTES: TREES SHOULD BE PLANTED WITH THE ROOT FLAIR AN INCH OR TWO ABOVE FINAL GRADE. IN ADDITION TO THIS, TREES NEED TO BE MULCHED WITH A MULCH RING THAT IS 4-6' IN DIAMETER AND 2-4" DEEP. CRITICAL ROOT ZONE (CRZ) IS ASSUMED TO BE A MINIMUM OF 24" BELOW GRADE FOR ALL TREES. CRZ IS SHOWN ON PLAN AT 12" DIA PER 1" TRUNK CALIPER. PLANT SCHEDULE TABLE NOTES: "CODE PQ/XQ" IN THE TABLE REFERS TO THE PROPOSED QUANTITY/EXISTING QUANTITY OF THE SPECIFIC PLANTING. SHEET NUMBER: CPM: SDM: RDM: 03/03/2023#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 40 FLAG NOTES: 4/04/2023 Mask Text