HomeMy WebLinkAboutKUM & GO #0951 - FDP230009 - SUBMITTAL DOCUMENTS - ROUND 2 - SUPPORTING DOCUMENTATIONUTILITY TRANSFORMER 208Y/120V 3Ø 4W GROUND BUS NEUTRAL BUS TO BUILDING FOOTING (UFER) TO WATER SERVICE TO ABOVE GROUND METAL PIPING TO STRUCTURAL STEEL TELEPHONE BOARD (TTB) TO GROUND BAR AT MAIN TO GROUND ROD(S) IG BUS PNLBD P1225PNLBD P2224PNLBD P3224PNLBD F124PNLBD MDPPNLBD RPA541531532043P 200A NEMA 3R 200A PROTOCOL AM 3P 150A NEMA 3R 200A 3P 150A NEMA 3R 200A RTU-1M RTU-2M 1004TG0G1200G1200G1200G200G150MBJ MBJ 3P 1000A NEMA 3R 1000AS1004BUILDING LOAD SUMMARY (MDP) BUILDING OCCUPANCY: STORE BUILDING SQUARE FOOTAGE: 6000 SERVICE VOLTAGE: 208Y/120 V LOAD TYPE CONNECTED LOAD DEMAND FACTOR NEC DEMAND EXISTING LOAD (E) 0 VA 100% 0 VA COOLING (C) 0 VA 0% 0 VA HEATING (H) 97994 VA 100% 97994 VA LIGHTING (L) (PER NEC-220) 18000 VA 125% 22500 VA RECEPTACLES (R) 14128 VA 85% 12064 VA MOTORS (M) 894 VA 100% 894 VA SUPPLEMENTAL HEAT (U) 24000 VA 100% 24000 VA MISC EQUIP (Z) 42637 VA 100% 42637 VA REFRIGERATION (F) 65185 VA 100% 65185 VA SIGNAGE (S) 5701 VA 125% 7126 VA KITCHEN (K) 32888 VA 65% 21377 VA LARGEST MOTOR 1200 VA 125% 1500 VA SHOW WINDOW (W) 9300 VA 125% 11625 VA TRACK LIGHTING 0 VA 100% 0 VA TOTAL LOAD 311927 VA 306902 TOTAL AMPACITY 866 AMPS 852 SERVICE AMPACITY AMPS 1000 SPARE CAPACITY AMPS 148 UTILITY TRANSFORMER DESIGN CRITERIA: PAD MOUNT UTILITY TRANSFORMER SECONDARY VOLTAGE: 208Y/120V 3PH, 4W FOR PURPOSES OF DESIGN A VALUE OF 22,030 AMPS SHORT CIRCUIT CURRENT IS CONSIDERED AT THE SERVICE ENTRANCE. VALUE PROVIDED BY ROB IRISH OF CITY OF FORT COLLINS. ELECTRICAL SERVICE NOTE: UTILITY COMPANY : CITY OF FORT COLLINS UTILITY CONTACT: ROB IRISH UTILITY PHONE: 970-224-6167 F5 F6 F7F8F9F4F11F10 EO2EO4 C RK1 CURRENT LIMITING RK1 CURRENT LIMITING POWERWALL MANUFACTUERER INSTALLED EO1 F1 F3 M UTILITY METER CT CABINET NEMA 3R EO5 ST EO6 F2 SE RATED EO3 EO10 S F S F S F 6 E3.0 FUEL PUMP CONTROLS PETRO CONDUITS 5' - 0" ELECTRICAL GUTTER BY PETROLEUM VENDOR FINISHED FLOOR HOUSEKEEPING PAD BY ELECTRICAL CONTRACTOR CONTRACTOR TO PLACE PLACACARD ON PANELS STATING: "CAUTION -ENGINEERED SERIES COMBINATION SYSTEM RATED 65,000 AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED." 3' - 9" REFRIGERATION REMOTE PANEL RPA LIGHTING CONTACTORS PROVIDE (2) 1" CONDUITS TO ROOFTOP PROTOCOL REFRIGERATION SYSTEM FOR CONTROL WIRING PROVIDE (1) 2" CONDUIT FOR LOW VOLTAGE CABLE. CONDUIT SHALL ENTER AT TOP RIGHT SIDE OF THE CABINET.1' - 1"HOUSEKEEPING PAD BY ELECTRICAL CONTRACTOR FROM ADJACENT WALL 1' - 3" MDP 3' - 6" FINISHED FLOOR HOUSEKEEPING PAD BY ELECTRICAL CONTRACTOR BRANCH MOUNTED MAIN. FURNISH WITH ENERGY REDUCTION MAINTENANCE SETTING MONITORING PNL F PNL P3 PNL F CONT 125A (1) DUPLEX AND (1) QUAD RECEPTACLE ON SIDE BY E-WALL VENDOR PNL P1 PNL P2 3' - 6" PROVIDE (2) 2" CONDUITS TO DATA RACK FOR LOW VOLTAGE CABLES. PROVIDE (2) 2" CONDUITS FOR INCOMING TELEPHONE SERVICE. PROVIDE (1) 1" CONDUIT FOR IRRIGATION CONTROL CABLES LANDSCAPE IRRIGATION CONTROLLER TELEPHONE DEMARC DOUBLE DUPLEX RECEPTACLES PER PLANS (TYPICAL OF 2) PROVIDE PLYWOOD BACKBOARD FOR TELEPHONE EQUIPMENT FINISHED FLOOR SOIL OR SAND FILL GROUND ROD(S) 3/4" x 8'-0" MIN REMOVABLE BOLTED/SECURED COVER -LABELED "GROUND". USE SATURATED FELT PAPER AROUND COVER WHEN POURING CONCRETE. TRAFFIC AREAS: PROVIDE POLYMER CONCRETE BOX AND COLLAR RING OR APPROVED ALTERNATE MATERIAL. REMOVABLE COVER SHALL BE REINFORCED CONCRETE, STEEL, CAST IRON OR APPROVED ALTERNATE MATERIAL. BOX, RING AND COVER SHALL HAVE A MINIMUM H-20 LOAD RATING AND SHALL BE SUITABLE FOR LOCATION. PROVIDE LOW-RESISTIVITY, GROUND-ENHANCING BACKFILL MATERIAL AS NEEDED FOR HIGH GROUND RESISTIVITY OR IF RECOMMENDED BY THE ELECTRODE MANUFACTURER. FINISHED GRADE (PAVED) NON-TRAFFIC AREAS: PROVIDE PROVIDE HIGH DENSITY POLYETHYLENE OR APPROVED ALTERNATE MATERIAL. BOX, RING AND COVER SHALL HAVE A MINIMUM ANSI 77 TIER 8 LOAD RATING AND SHALL BE SUITABLE FOR LOCATION. GROUNDING ELECTRODE CONDUCTOR 1'-0" MIN FINISHED GRADE (GRASS)1'-0"4"GROUNDING ELECTRODE CONDUCTOR (IF APPLICABLE) GROUND ROD CLAMP OR EXOTHERMIC WELD 4" MIN FAXTEL Sheet No. This drawing was prepared for use on a specific site contemporaneously with its issue date and it is not suitable for use on a different project site or at a later time. Use of this drawing for reference or example on another project requires the services of properly licensed architects and engineers. Reproduction of this drawing for reuse on another project is not authorized and may be contrary to the law. BRR Original printed on recycled paper Copyright Notice Project No. Sheet Title Issues & Revisions ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com Tel: 913-262-9095 Fax: 913-262-9044 Drawn by: Professional Seal Project Manager: Document date: Checked By: Project Phase Project Name Project Address TREVOR TYSON HOLCOMB WWW.HENDERSONENGINEERS.COM 2/27/2023 1:13:08 PMELECTRICAL ONE-LINE AND SCHEDULES E3.0 63109510 02/28/23 JC DC/AH PROTO RIGHT GLAZING AH KUM & GO 949 E Prospect Rd. Fort Collins, CO #0951 DEAN W. CHANDLER2150004674 2150004674 8345 LENEXA DRIVE, SUITE 300 LENEXA, KS 66214 913.742.5000 913.742.5001 NTS1ONE-LINE DIAGRAM EO1 SURGE SUPPRESSION DEVICE (SPD) IS FURNISHED WITH POWERWALL. SPD SHALL BE INTERNALLY MOUNTED. REFER TO SPECIFICATIONS FOR REQUIREMENTS. EO2 ROUTE ISOLATED GROUND CONDUCTOR FOR PANELBOARD P1 TO MAIN SERVICE GROUND GROUNDING POINT. EO3 FUEL DISPENSER PANELBOARD AND MAIN CONTACTOR ARE FURNISHED AND INSTALLED IN POWERWALL. COORDINATE ALL REQUIREMENTS FOR INSTALLATION WITH FUEL CONTRACTOR. EO4 REFRIGERATION REMOTE PANEL A (RPA) FURNISHED BY REFRIGERATION SUPPLIER AND INSTALLED BY ELECTRICAL CONTRACTOR. EO5 #4/0 AWG EXOTHERMICALLY WELDED TO BUILDING STEEL AND BONDED TO THE INCOMING METAL WATER PIPING PER N.E.C. GROUNDING (ART. 250), LOCAL UTILITY REQUIREMENTS, AND PER LOCAL AUTHORITY. PROVIDE BONDING JUMPER IN "MAIN SERVICE DISCONNECT SWITCH". SIZED IN ACCORDANCE WITH N.E.C. ARTICLE 250-30. SEE GROUNDING ELECTRODE DETAIL, THIS SHEET. EO6 ELECTRICAL POWER-WALL FURNISHED BY OWNER. EO10 INSTALL FEEDERS UNDERSLAB. COORDINATE ROUTING W ITH OTHER TRADES PRIOR TO INSTALLATION. ONE-LINE PLAN NOTES FEEDER TAG FEEDER DESCRIPTION 54 (4)#8, (1)#10G, 3/4" C 124 (4)#1, (1)#6G, 1-1/2" C 153 (3)#1/0, (1)#6G, 1-1/2" C 204 (4)#3/0, (1)#6G, 2" C 224 (4)#4/0, (1)#4G, 2-1/2" C 225 (4)#4/0, (1)#4G, (1)#4 IG, 2-1/2" C 1004 (3) 3" C, EACH W/ (4)-400kcmil, (1)#2/0G G150 #6 COPPER GROUND, 3/4” C G200 #4 COPPER GROUND, 3/4” C G1200 #3/0 COPPER GROUND, 3/4” C MBJ MAIN BONDING JUMPER, #4/0 S103 (3)#3, 1-1/4" C S1004 (3) 3" C, EACH W/ (4)-400kcmil TG0 #1/0 cu ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN/THWN-2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. CIRCUIT SCHEDULE: ELECTRICAL ONE-LINE GENERAL NOTES 1.ALL ELECTRICAL PANELBOARDS SHALL BE MANUFACTURED BY SQUARE D. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2.ELECTRICAL POWERWALL FURNISHED BY OWNER. CONTACT DAVE ROACH, CD CONTROLS, 706-356-0325, DAVEROACH@CDCONTROLS.COM FOR COORDINATION PRIOR TO ROUGH-IN. 3. THE POWERWALL IS PART OF A NATIONAL RECOGNIZED TEST LABORATORY LISTED BREAKER RATED SYSTEM THAT REQUIRES THE DOWN STREAM BREAKERS TO BE TESTED WITH THE POWERWALL AS A COMPLETE SERIES RATED LISTED SYSTEM. THE MANUFACTURER WILL PROVIDE SPECIFIC BREAKER TYPES (CATALOG NUMBERS) TO COMPLY WITH THE TESTS FOR A SERIES RATED SYSTEM. ANY REPLACEMENT BREAKERS SUPPLIED SHALL MATCH EXISTING TYPES (CATALOG NUMBERS) SUPPLIED BY THE ORIGINAL SYSTEM MANUFACTURER. FAILURE TO SUPPLY THE CORRECT BREAKERS WILL VOID THE SERIES RATED SYSTEM RATING OF THE COMPLETE ELECTRICAL SYSTEM. 4. CIRCUIT BREAKERS RATED 1200A OR HIGHER SHALL HAVE APPROPRIATE DOCUMENTATION AND METHOD TO REDUCE CLEARING TIME IN ORDER TO REDUCE ARC FLASH ENERGY PER CODE. PROVIDE ELECTRONIC TRIP UNIT WITH INSTANTANEOUS TRIP AND ENERGY-REDUCING MAINTENANCE SWITCH WITH LOCAL STATUS INDICATOR FOR COMPLIANCE. PROVIDE PROVISIONS TO INTERFACE WITH OWNER ALARM/MONITORING SYSTEM TO INDICATE MAINTENANCE SWITCH STATUS. 1/2" = 1'-0"3 MECH/ELEC ROOM ELEVATION 1 1/2" = 1'-0"4 RPA PANEL ELEVATION 1/2" = 1'-0"2 MECH/ELEC ROOM ELEVATION 11 RTU-2 3 3 18660 M CU 1 Set(s) of 1 AWG 7293 -- 208 60 0.85 136 0.000160 0.000057 0.554811 1.278 0.44 8190 -1.13% -2.58% 11 10 RTU-1 3 3 18660 M CU 1 Set(s) of 1 AWG 7293 -- 208 90 0.85 136 0.000160 0.000057 0.554811 1.918 0.34 6396 -1.69% -3.15% 10 9 Protocol A 3 3 18660 M CU 1 Set(s) of 3/0 AWG 12844 -- 208 65 0.9 153 0.000079 0.000052 0.451027 0.786 0.56 10446 -0.78% -2.23% 9 8 Panelboard RPA 3 3 18660 M CU 1 Set(s) of 8 AWG 1557 -- 208 20 0.9 40 0.000780 0.000065 0.451027 1.996 0.33 6228 -0.49% -1.94% 8 7 Panelboard F 3 3 18660 M CU 1 Set(s) of 1 AWG 7293 -- 208 8 0.9 61 0.000160 0.000057 0.451027 0.170 0.85 15943 -0.07% -1.52% 7 6 Panelboard P3 3 3 18660 M CU 1 Set(s) of 4/0 AWG 15082 -- 208 6 0.9 191 0.000063 0.000051 0.451027 0.062 0.94 17574 -0.08% -1.53% 6 5 Panelboard P2 3 3 18660 M CU 1 Set(s) of 4/0 AWG 15082 -- 208 6 0.9 137 0.000063 0.000051 0.451027 0.062 0.94 17574 -0.05% -1.51% 5 4 Panelboard P1 3 3 18660 M CU 1 Set(s) of 4/0 AWG 15082 -- 208 8 0.9 132 0.000063 0.000051 0.451027 0.082 0.92 17239 -0.07% -1.52% 4 3 Panelboard MDP 2 3 19229 M CU 4 Set(s) of 350 kcmil 19704 -- 208 15 0.9 1161 0.000039 0.000050 0.451027 0.030 0.97 18660 -0.21% -1.45% 3 2 Disconnect Switch 1 3 23338 NM CU 4 Set(s) of 350 kcmil 22737 -- 208 100 0.9 1161 0.000038 0.000040 0.451027 0.214 0.82 19229 -1.25% -1.25% 2 Motor Contribution 218 The connected full load motor amps (includes compressors) on the system 1 Utility Service Point 22,030 at the secondary of the utility transformer Source Isc + 6X Motor Contribution = 23338 1 (Radians) Conduit Type/ TX Material Quantity of Parallel Sets and Bus/ Phase & Neutral Size Resistance (R) Reactance (X) Arccos (pf)Type Degree Rise kVA New Xfmr Z Existing Xfmr Z Secondary Voltage Tap Setting Fault Point (F#) Bus/Feeder Description Source (Fault Point) Phase Source Isc (amps) Feeder Conductor 'C' Value Busway 'C' Value L-L Voltage (E) Circuit Length (L) Load Power Factor (pf) Circuit Load (Amperage) Conductor Transformer f M Fault Current (amps) Voltage Drop (%VD) Cumulative Voltage Drop (%VD) Fault Point (F#) System Voltage: 208Y/120V - 3 phase NM - Non Magnetic Conduit, M - Magnetic Conduit, FB - Feeder Busway, PB - Plug-in Busway, TX - Transformer Feeder Types = C ="C" Factor from Bussman table where "C" = 1 / impedance per linear foot L = Length of circuit E = Line to line volts X= reactances in ohms per LF Vs=Secondary voltage R=resistance in ohms per LF IS= Secondary short circuit current %VD CUM= Cumulative Voltage Drop from Fault Point 1 to Fault Point # Vp = Primary voltage IP = Primary short circuit current C x E 100,000 x KVA ISC (2) = short circuit current at fault point 2 Feeder: f (1Ø)= 2 x L x Isc XFMR: f (1Ø)= IP(sca)x Vp x %Z %VD= ((R x cos(arccos(pf)) + X x sin(arccos(pf))) x 2 x L/# x I) / E ISC (1) = short circuit current at fault point 1 C x E 100,000 x KVA Vs VOLTAGE DROP (1Ø): ISC (2) = ISC(1) x M(1)M= 1/(1+f) Feeder: f (3Ø) = 1.732 x L x Isc XFMR: f (3Ø) = IP(sca)x Vp x 1.73 x %Z IS(sca)= Vp x M x IP(sca)%VD= ((R x cos(arccos(pf)) + X x sin (arccos(pf))) x L/# x I x 1.73) / E The following calculations are based on the "Point-by-Point" method where:VOLTAGE DROP (3Ø): Distances are for calculation purposes only and shall not be used for contractor takeoffs nor bidding - Contractor shall notify Engineer of any field condition that results in a change of 10% or greater circuit distance Short-Circuit and Voltage Drop Calculations 1/2" = 1'-0"5 TELEPHONE ELEVATION 12" = 1'-0"6 GROUNDING TEST WELL INSTALLATION NO. DATE DESCRIPTION 02/27/2023