HomeMy WebLinkAboutHARMONY MARKET PUD, 6TH FILING, RED ROBIN - PRELIMINARY & FINAL - 54-87T - CORRESPONDENCE - STAFF'S PROJECT COMMENTSCommW Planning and EnvironmentArvices
Planning Department
City of Fort Collins
gagman
April 22, 1994
Mr. Craig Cahen -
CS Architects
7555 East Hamden Avenue, Suite 525
Denver, CO 80231
Dear Craig:
Staff has reviewed the request for- Red Robin at Harmony Market
P.U.D., Preliminary and Final, being the Sixth Filing of Harmony
Market. The following comments are offered:
1. The Transportation Department is interested in a further
evaluation of the issues relating to the geometrics regarding the
recommended double left turn lanes at the Harmony/Boardwalk
intersection. Also, the traffic study needs to clarify the traffic
generation on the Saturday noon peak as well as the weekday peaks.
It is recommended that a representative from John Aldridge and
Associates contact Tom Vosburg of the City's Transportation
Department to discuss these issues.
2. The traffic study recommends introducing a new curb cut on
Boardwalk to allow direct vehicular access to the front of Sams and
Builders Square. This new curb cut will not be allowed. Although
this solution may be "common" and "popular" in other centers, it is
in direct contrast to one of the primary design objectives of this
shopping center as envisioned at its inception.
3. The City's Light and Power Department needs to be contacted
regarding the location of the electrical transformer. It will be
recalled from Conceptual Review that the location of the
transformer is critical in that it must not be visible from public
roadways, yet must be accessible (within 10 feet), from one side
only, by hard surface. The transformer must be screened.
Screening may either be a solid enclosure, with gates, that meets
the clearance specifications of Light and Power. Or, screening may
be by landscape materials. Please indicate the location of the
transformer on both the Site Plan and Landscape Plan.
4. On the plat, the control monument at the northeast corner of
Section One is not as shown on the plat.
5. The site shall be accessible to persons with disabilities in
accordance with Uniform Building code Section 3103 and U.B.C.
281 North College Avenue • P.O. Box 580 • Fort Collins, CO 80522-0580 • (303) 221-6750
r
Appendix Section 3106. The plans should indicate designated and
marked accessible routes between building and public way and
accessible parking and building. Provide parking and. signs per
Appendix Section 3107. Four handicap parking spaces are required
in accordance with U.B.C. Appendix 3107 and Table A-31-A.
6. Since the building exceeds 5,000 square feet in area, an
automatic fire suppression system is required in accordance with
Sections 3802, U.B.C. as amended by the City of Fort Collins.
7. .There is a discrepancy between the Site and Landscape Plans on
the location of the sidewalk along Harmony Road,. .Please verify the
location. If the location is on the southerly portion of the
landscaped area, then there should be a sidewalk connection from
Red Robin parking lot. If the walk is on the northerly portion,
and separated from Red Robin by the berm, then no sidewalk
connection will be necessary. Also, the landscape plan should
indicate the existing berm along Harmony Road.
8. The light standard detail should state that the fixtures are
to match the style of the existing poles.within the center. The
City is concerned that the center be as unified as possible despite
different developers on the various parcels. (Steeles's fixtures
do not match due to an oversight by the architect/builder. We are
concerned that there not be a third style introduced.)
9. The light standard note should delete references to metal
halide as a light source. During the deliberations of Harmony
Market as community/regional shopping center, the surrounding
neighborhoods have expressed a strong concern about light
pollution. In order to minimize over -illumination, and due to the
proximity of single family homes to the north, light sources should
be as soft as possible.
1.0. Please note that the standard parking stall depth in Fort
Collins is 19 feet, not 18 feet. A stall may be reduced to 17 feet
if the front of the vehicle overhangs a landscaped area, or a
sidewalk with a minimum width of six feet.
11. The landscape plan looks terrific. Please note, however, that
there are two trees within a landscape island that are not keyed to
the legend. We believe these to be Skyline Honey Locust. Also,
there are two trees along Boardwalk keyed as "PA" and we believe
these to be "APA", Autumn Purple Ash. Please verify the type and
location of deciduous canopy trees as the quantities on the plan do
not match the quantities in the legend.
12. Please verify the quantity of Spring Snow Crabs. The Plan
indicates four "SSC" which are labeled as three "SSC" between the
structure and Boardwalk Drive. It appears that the legend may be
short one deciduous ornamental tree.
0
13. Please add this standard note to the Landscape.Plan:
"All landscaping to be installed priorto issuance of a
Certificate of. Occupancy or secured with an irrevocable letter
of credit, performance bond, or escrow in the amount of 125%
of the landscape materials."
14. The Architectural Elevations indicate the use of red neon
tubing along the perimeter of the roof line. This is considered to
be an excessive use of lighting as an element of advertising, not
as an element of quality architecture. Such tubing is out of
character with both the existing structures within the center and
the vision for the balance of the center. Neon tubing is not a
feature that will be allowed to be introduced to the center.
Please delete red neon tubing from the Architectural Elevations.
15. Staff is concerned that the building lacks brick banding to
tie into the architectural theme of the center. The lower four
foot band should be brick, not a light earth tone synthetic stucco.
It will be recalled from Conceptual Review that one of the City's
major concerns is that there be unifying architectural elements to
tie the pads to the anchors. Please note that.19T Bank is using
brick as the primary exterior material.
16. It would be helpful to describe more fully what is meant by
"light" and "medium" earth tones. Would this be light brown and
dark, reddish brown?
17. On the northwest and southwest elevations, it appears that the
red batten seam metal roof is to be illuminated by light fixtures.
Staff is very concerned about introducing decorative exterior
lighting on such a colorful reflective surface. It must be
emphasized that the planning approval process for Harmony Market
was extremely controversial (being appealed to City Council). The
public acceptance is based on upgraded design features not found in
most centers. A key element in neighborhood compatibility is
lighting. (Please note the lowered light poles on the perimeter of
Sams and the subdued building lighting.) Staff is reluctant to
allow purely additional decorative lighting. It is suggested that
the red seam metal roof is a sufficient attraction that can stand
on its own, without direct lighting. Perhaps a more creative
solution can be found that meets the needs reduced lighting and the
needs of Red Robin.
18. Please indicate the material of the patio screen wall.
19. Please be aware that signage on the P.U.D. is for illustrative
purposes. Sign permits will be issued based on the Sign Code.
20. Are there any bike racks? Staff recommends that bike racks be
provided for both customers and employees. Racks should be
visible, well illuminated, and permanently anchored to concrete
and not interfere with pedestrian walks.
21. Staff applauds the strong pedestrian linkage to the balance of
the center. This is a creative solution to a problem that is not
typically addressed in a functional and attractive manner in most
centers.
22. The following minor comments apply to the Site Plan:
A. Please indicate the location of the site on the vicinity map.
B. Under "Site Data," please indicate the percentage of the total
of the building, landscaped, and hard surface areas.
C. The plat indicates that the owner is Oak Farm, Inc. The Site
Plan indicates G.T. Land. We believe the plat to be correct.
D. The Notarial Statement is usually located directly under the
owner's signature.
E. Please correct the spelling in the Planning and Zoning Board
approval block.
F. Please add the surrounding zoning and land uses.
G. Please indicate the loading zone and/or service entry.
23. Please add the following standard notes to the Site Plan.:
A. Refer to Utility Plans for location of utilities and detention
areas.
B. Building will conform to the minimum Colorado Energy Code
Requirements.
C. Sidewalks and ramps will conform to City Standards.
D. All rooftop mechanical equipment will be'totally screened by
the rooftop parapet wall.
E. The trash enclosure will• mounted on concrete, and be
constructed of synthetic stucco to match the building. one
side shall be a solid screen gate.
F. Bicycle racks will be permanently anchored to concrete and
will not interfere with pedestrian sidewalks
G. Restaurant to be provided with an exterior grease trap as per
the specifications of the City of Fort Collins Wastewater
Utility.
24. It appears that the P.U.D. is set of four sheets, not six.
Please label sheet one of four, etc.
This concludes Staff comments at this time. Other comments may be
forthcoming from the Planning Department' other departments or
agencies during the review process. In order to stay on schedule,
please note the following deadlines for the May 23, 1994 Planning
and Zoning Board hearing:
Plan revisions (three sets) are due May 4, 1994.
P.M.T.'s, 10 prints (folded) colored renderings are due May 16th.
As always, please feel free to call our office to discuss these
comments or to set up an appointment to discuss the issues in
depth.
Sincerely:
ce
4
Ted Shepard
Senior Planner
xc: Kerrie Ashbeck, Civil Engineer