Loading...
HomeMy WebLinkAboutWORTHINGTON STORAGE - FDP220016 - SUBMITTAL DOCUMENTS - ROUND 3 - PHOTOMETRIC PLANPROPERTY LINE 0.1 0.2 0.1 0.2 0.4 0.3 0.1 0.7 0.4 0.0 0.0 0.7 0.4 0.0 0.0 0.0 0.7 0.4 0.0 0.0 0.0 0.7 0.4 0.0 0.0 0.0 0.5 0.3 0.0 0.0 0.0 0.4 0.3 0.0 0.0 0.0 0.5 0.3 0.0 0.0 0.5 0.4 0.0 0.6 0.4 0.0 0.0 0.6 0.0 0.0 0.5 0.0 0.0 0.5 0.1 0.1 0.5 0.0 0.1 0.9 0.6 0.0 0.0 0.9 0.5 0.0 0.1 0.4 0.0 0.1 0.6 0.4 0.0 0.1 0.6 0.4 0.1 0.5 0.2 0.1 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.1 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 1.5 1.6 2.1 2.8 2.5 1.4 3.3 3.4 2.2 1.3 4.5 3.7 2.1 1.0 1.8 3.5 3.7 1.1 0.7 0.8 1.4 1.9 2.7 1.0 0.8 1.1 1.1 0.7 1.8 1.9 1.7 1.3 1.6 1.7 1.0 0.7 1.6 1.8 1.6 1.5 1.7 1.2 1.0 0.7 1.9 1.9 1.9 1.8 1.8 1.7 1.3 1.1 1.5 1.9 1.5 1.8 1.8 1.5 1.3 1.0 1.4 1.7 1.8 1.8 1.6 1.7 1.2 0.7 1.7 1.8 1.8 1.7 2.0 1.4 1.1 0.7 0.3 0.6 1.2 1.3 2.1 1.8 1.3 1.1 0.9 0.1 0.2 0.4 0.6 1.9 1.9 1.8 1.3 1.0 0.1 0.2 0.4 1.5 1.5 1.8 1.4 1.3 0.1 0.3 1.1 4.0 7.1 1.7 1.8 1.8 1.0 0.7 0.1 0.2 0.7 1.8 4.1 1.6 1.7 1.2 0.9 0.6 0.1 0.2 0.4 1.1 1.6 1.8 1.6 1.4 1.0 0.7 0.1 0.2 0.4 0.6 1.2 1.6 1.9 1.7 1.2 0.6 0.3 0.1 0.3 0.6 1.1 1.4 1.3 1.2 1.5 0.8 0.3 0.1 1.5 1.9 1.9 1.6 0.8 0.4 0.2 1.2 1.6 2.0 1.4 0.1 1.3 1.9 1.6 1.5 1.6 1.5 1.4 1.6 1.2 1.6 1.6 1.6 1.6 1.8 1.9 1.3 1.7 2.2 1.5 2.0 1.8 0.2 1.3 1.7 1.5 1.3 1.8 1.1 1.3 1.3 1.6 4.6 2.5 1.0 1.2 1.5 2.0 2.4 2.6 2.1 0.6 1.2 1.7 2.3 2.4 2.7 2.6 1.8 1.4 0.2 0.5 0.9 1.8 2.6 2.9 2.5 2.5 1.8 0.1 0.2 0.5 1.1 2.2 1.9 1.9 2.2 0.3 0.6 1.2 1.7 1.2 0.2 0.5 0.8 T S1 MH: 20 S1 MH: 20 S1 MH: 20 S1 MH: 10 S3 MH: 20 S1 MH: 10 S1 MH: 10 ES1 MH: 8 S1 MH: 10 S1 MH: 10 S1 MH: 15 Luminaire Schedule Symbol Qty Label Arrangement Total Lamp Lumens LLF Description 9 EDGE-4M-E_EDITABLE SINGLE 7311 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires 1 AFF_FCT SINGLE N.A.0.900 AFF FCT 1 EDGE-4M-E_EDITABLE_1 SINGLE 11638 0.900 For use with Series E EDGE, 228, 304 and LEDway Luminaires Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min 10' Beyond Illuminance Fc 0.12 0.9 0.0 N.A.N.A. entry drive Illuminance Fc 0.20 0.2 0.2 1.00 1.00 entry drive_1 Illuminance Fc 1.45 7.1 0.1 14.50 71.00 ELECTRICAL PHOTOMETRIC SITE PLAN REVISIONSCONSULTING ENGINEERSCONTRACTOR3/8/2023 3:54:44 PMJOB NO: PE : STRUCTURAL:ELECTRICAL:PLUMBING:MECHANICAL:HENDERSON ENGINEERS, INC.8311 West Sunset Road, Suite 240Las Vegas, NV. 89113(P) 702.365.3522CIVIL:999 18th ST., STE. 2110DENVER, CO 75206(P) (303) 801-1767WWW.ARCOMURRAY.COMSELF STORAGE PROJECT for:Ft. Collins, ColoradoDATE : THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF IT IS NOT TO BE USED FOR PURPOSES. LICENSE #LICENSE #LICENSE # DEAN W. CHANDLER 54612 CONSTRUCTION PRELIMINARY SUBMITTAL REV1: 03/08/2023 SCALE: 1/32"=1'-0" PHOTOMETRIC SITE PLAN1 3/4" RNC NO SCALE POLE BASE DETAIL2 5/8" X 8' DRIVEN GROUND ROD WITH #6 CU. GROUND BONDED TO POLE GROUNDING LUG AND TO GROUND ROD ELECTRICAL CIRCUIT TO LIGHT POLE. REFER TO SITE PLAN AND PANELBOARD SCHEDULES FOR SIZES OF CONDUITS AND CONDUCTORS RNC (TYP) LINE OF GRADE OR PAVING ANCHOR BOLTS, PER MANUFACTURER GROUT POLE BASE PLATE BOND ELECTRICAL EQUIPMENT GROUNDING CONDUCTOR RUN WITH CIRCUIT TO LIGHT POLE GROUNDING LUG. HANDHOLE WITH REMOVABLE COVER AS SPECIFIED LIGHT POLE. RE: LIGHT FIXTURE SCHEDULE FOR TYPE. OPTIONS AND ACCESSORIES AS SPECIFIED. RE: LIGHT FIXTURE SCHEDULE FOR NUMBER AND TYPE OF HEADS AND CONFIGURATION Y3 Y2 Y1 REINFORCED CONCRETE FOUNDATION. SIZE AND TYPE AS REQUIRED TO MEET SITE CONDITIONS X Y1 Y3 Y2 TABLE OF DIMENSIONS* REFER TO LIGHT FIXTURE SCHEDULE FOR POLE HEIGHT 1/4 OF POLE HEIGHT Y1 *NOTE: ALL DIMENSIONS ARE APPROXIMATE AND ARE SHOWN FOR REFERENCE ONLY. POLE FOUNDATION SHALL BE DESIGNED AND SEALED BY A PROFESSIONAL STRUCTURAL OR CIVIL ENGINEER LICENSED IN THE PROJECT STATE AND SUBMITTED AS PART OF THE SUBMITTAL PROCESS. POLE HEIGHT < 16' = 1'-6" POLE HEIGHT > 16' = 2'-0" VEHICULAR AREAS - 3'-0" NON-VEHICULAR AREAS - 0'-6" X ALL EXTERIOR SITE LIGHTING SHALL BE PER CITY OF FORT COLLINS STANDARDS, LATEST EDITION (SECTION 3.2.4 - EXTERIOR SITE LIGHTING). 1 1 1 1 1 1 1 1 1 1 1 1 1 15 of 17 04/21/2023WORTHINGTON STORAGE16 OF 18 ELECTRICAL CUTSHEETS REVISIONSCONSULTING ENGINEERSCONTRACTOR6/21/2022 4:15:39 PMJOB NO: PE : STRUCTURAL:ELECTRICAL:PLUMBING:MECHANICAL:HENDERSON ENGINEERS, INC.8311 West Sunset Road, Suite 240Las Vegas, NV. 89113(P) 702.365.3522CIVIL:999 18th ST., STE. 2110DENVER, CO 75206(P) (303) 801-1767WWW.ARCOMURRAY.COMSELF STORAGE PROJECT for:Ft. Collins, ColoradoDATE : DEAN W. CHANDLERS1 ES1 ES1 S2 S3 16 of 17 04/21/2023WORTHINGTON STORAGE17 OF 18 ELECTRICAL PRELIMINARY ONE-LINE DIAGRAM REVISIONSCONSULTING ENGINEERSCONTRACTOR6/21/2022 4:15:49 PMJOB NO: PE : STRUCTURAL:ELECTRICAL:PLUMBING:MECHANICAL:HENDERSON ENGINEERS, INC.8311 West Sunset Road, Suite 240Las Vegas, NV. 89113(P) 702.365.3522CIVIL:999 18th ST., STE. 2110DENVER, CO 75206(P) (303) 801-1767WWW.ARCOMURRAY.COMSELF STORAGE PROJECT for:Ft. Collins, ColoradoDATE : DEAN W. CHANDLERSCALE: NONE PRELIMINARY ONE-LINE DIAGRAM1 TX-1 75 KVA 480V- 208Y/120V T224G2123MDP ELEC ROOM 600 AMPS 480Y/277V 3Ø 4W BRACED AT 42000 A.I.C.104100A 3P 125A 3P PANEL LP1 PANEL P1 PANEL P2 (4x) 3P SPACE 125A 3P PANEL M1124 113110A 3P CPT R 200AS 3P 110AF ELEV 1 CONT PANEL 40 ELEVATOR ST H 113M 224AS604M GROUND BUS NEUTRAL BUS TO GROUND ROD(S) TO BUILDING FOOTING (UFER) TO WATER SERVICE TO ABOVE GROUND METAL PIPING TO STRUCTURAL STEEL TELEPHONE BOARD (TTB) TO GROUND BAR AT MAIN G6G4G20G20G20TG6G30 G30 UTILITY METER NEW PAD MOUNTED UTILITY TRANSFORMER 300KVA, 480Y/277V, 3Ø, 4W SECONDARY CT CABINET NEMA 3R D-MDP 600A 3P NEMA 3R A604FROM UTILITY MAIN SERVICE DISCONNECT SWITCH FEEDER SCHEDULE: SIZES ARE BASED ON COPPER (CU) THHN/THWN-2 INSULATION, UNO. NUMBER DESIGNATIONS PRECEDED BY "A" INDICATE THAT THE SIZE IS BASED ON ALUMINUM (AL) WIRE. AL CONDUCTOR SIZES ARE BASED ON XHHW-2 INSULATION, UNO. ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATIONS, UNO. CONDUIT SIZES SHOWN ARE APPROPRIATE FOR SCHEDULE 40 PVC, EMT, GRS, IMC AND RMC; ADJUST SIZE AS NEEDED FOR OTHER RACEWAY TYPES. FOR ANY OTHER CONDITIONS MODIFY SIZES PER CODE. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. 104 100A, (4)#3, (1)#8G, 1-1/4" C 113 110A, (3)#2, (1)#6G, 1-1/4" C 123 125A, (3)#1, (1)#6G, 1-1/4" C 124 125A, (4)#1, (1)#6G, 1-1/2" C 224 225A, (4)#4/0, (1)#4G, 2" C A604 600A, (2) 3" C, EACH W/ (4)-500kcmil, (1)#2/0G AS604 600A, (2) 3" C, EACH W/ (4)-500kcmil G2 GND, #2 COPPER GROUND, 3/4" C G20 GND, #2/0 COPPER GROUND, 3/4" C G30 GND, #3/0 COPPER GROUND, 1" C G4 GND, #4 COPPER GROUND, 3/4" C G6 GND, #6 COPPER GROUND, 3/4" C T224 225A, (4)#4/0, (1)#2 SSBJ, 2-1/2" C TG6 #6 cu, Less than 13' 17 of 17 04/21/2023WORTHINGTON STORAGE18 OF 18