Loading...
HomeMy WebLinkAboutSTANFORD SENIOR LIVING - FDP210017 - PLANS - SITE, LANDSCAPE & ELEVATIONS PLANSDRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: COVER Printed On: 4/19/2023 9:42 AM File Name: 0 COVER.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 ESL Fort Collins LLC Hunter MacLeod 1550 Market St, Suite 200 Denver, CO 80202 OWNER/APPLICANT 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com COVER FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 C OF 7 STANFORD SENIOR LIVING FINAL DEVELOPMENT PLAN Director Signature PLANNING CERTIFICATE APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE CITY OF FORT COLLINS, COLORADO ON THIS ________ DAY OF ________, 20__. VICINITY MAP OWNER (SIGNED)Date THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME WITNESS MY HAND AND OFFICIAL SEAL. NOTARY PUBLIC ADDRESS THIS DAY OF MY COMMISSION EXPIRES: AS . (PRINT NAME) 20 .A.D., BY THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS OF THE REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN. OWNER'S CERTIFICATE SCALE: 1":500' LAND USE CHART PARKING REQUIREMENTS REQUIRED* PARKING (.33 / BED + 1 PER 2 EMPLOYEES ON MAJOR SHIFT MAX.) PROVIDED** LONG-TERM CARE FACILITY 0 MIN. - 69 MAX. 32 WITHIN THE GARAGE (INCLUDES 2 HC SPACES) AND 94 SURFACE SPACES (INCLUDES 4 HC SPACES) NOTES: *ASSUMES 35 EMPLOYEES ON A NORMAL MAJOR SHIFT AND 158 BEDS **THERE IS AN EXISTING 100 SPACE PARKING LOT LOCATED ON THIS PROPERTY WHICH IS CURRENTLY DESIGNATED AS COMMON AREA PARKING PER THE DECLARATION OF EASEMENTS, COVENANTS AND CONDITIONS. THIS PROPERTY WILL BE DISCHARGED FROM THE COMMON AREA, AS AGREED UPON, AT THE START OF CONSTRUCTION. EXISTING ZONING GENERAL COMMERCIAL (C-G) GROSS AREA (SF)% BUILDING COVERAGE 40,125 24.30 DRIVES AND PARKING (EXCLUDES PUBLIC ROW)47,032 28.49 OPEN SPACE AND LANDSCAPE (EXCLUDES PUBLIC ROW)47,888 29.01 HARDSCAPE (EXCLUDES PUBLIC ROW)13,104 7.94 PUBLIC STREET RIGHT-OF-WAY 16943 10.26 HARDSCAPE 1,880 DRIVES AND PARKING 12,478 LANDSCAPE 2,585 TOTAL GROSS COVERAGE 165,092.00 SF (3.79 AC)100.00 AREA COVERAGE NET AREA (SF)% BUILDING COVERAGE 40,125 27.08 DRIVES AND PARKING 47,032 31.75 OPEN SPACE AND LANDSCAPE 47,888 32.32 HARDSCAPE (WALKS & PLAZAS)13,104 8.85 TOTAL NET COVERAGE 148,149.00 SF (3.40 AC)100.00 SITE HORSETOOTH RD STANFORD STE MONROE DR.COLLEGE AVE (287)PETERSON STMMN MEDIUM DENSITY MIXED USE NEIGHBORHOOD DISTRICT CG GENERAL COMMERCIAL DISTRICT BICYCLE PARKING REQUIRED PROVIDED RESIDENTIAL PARKING SPACES 158 10 ALL ENCLOSED BUILDING HEIGHT CODE ALLOWED MAXIMUM STORIES*PROVIDED STORIES CODE HEIGHT (25' PER STORY MAX.)PROVIDED HEIGHT 7 STORIES 4 STORIES 20' MIN. - 175' MAX.VARIES, 49'-0" - 70'-0" MAX. A tract of land located in the Northwest Quarter of Section 2, Township 6 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado, and being more particularly described as follows: (PARCEL I) A PART OF LOT 3, STRACHAN SUBDIVISION, THIRD FILING, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, WHICH BEGINS AT A POINT WHICH BEARS N 85° 18' 00" E, A DISTANCE OF 58.78 FEET AND AGAIN N 89° 45' 30" E, A DISTANCE OF 192.00 FEET, AND AGAIN N 44° 45' 30" E, A DISTANCE OF 312.00 FEET AND AGAIN S 45° 14' 30" E, A DISTANCE OF 115.25 FEET, AND AGAIN S 48° 48' 34" E, A DISTANCE OF 49.58 FEET FROM THE SW CORNER OF LOT 2 OF THE STRACHAN SUBDIVISION, THIRD FILING AND RUN THENCE ALONG THE ARC OF A 398.41 FOOT RADIUS CURVE TO THE LEFT, A DISTANCE OF 236.29 FEET, THE LONG CHORD OF WHICH BEARS S 71° 18' 34" E, A DISTANCE OF 258.53 FEET; THENCE N 89° 45' 30" E, A DISTANCE OF 214.00 FEET; THENCE ALONG THE ARC OF A 15.00 FEET RADIUS CURVE TO THE RIGHT, A DISTANCE OF 23.56 FEET, THE LONG CHORD OF WHICH BEARS S 45° 14' 30" E A DISTANCE OF 21.21 FEET TO A POINT ON THE WEST RIGHT OF WAY LINE OF STANFORD ROAD; THENCE ALONG SAID RIGHT OF WAY LINE S 00° 14' 30" E, A DISTANCE OF 175.05 FEET, AND AGAIN ALONG THE ARC OF A 298.80 FOOT RADIUS CURVE TO THE RIGHT, A DISTANCE OF 198.17 FEET, THE LONG CHORD OF WHICH BEARS S 18° 45' 30" W, A DISTANCE OF 194.56 FEET, AND AGAIN ALONG THE ARC OF A 376.80 FOOT RADIUS CURVE TO THE LEFT, A DISTANCE OF 14.91 FEET, THE LONG CHORD OF WHICH BEARS S 36° 37' 30" W, A DISTANCE OF 14.91 FEET; THENCE N 53° 45' 30" W, A DISTANCE OF 141.48 FEET; THENCE S 44° 45' 30" W, A DISTANCE OF 260.46 FEET; THENCE S 89° 45' 30" W, A DISTANCE OF 24.83 FEET; THENCE N 45° 14' 30" W, A DISTANCE OF 142.44 FEET; THENCE N 44° 45' 30" E, A DISTANCE OF 278.02 FEET; THENCE N 21° 11' 34" W, A DISTANCE OF 87.60 FEET; THENCE N 45° 14' 30" W, A DISTANCE OF 96.53 FEET; THENCE N 44° 45' 30" E, A DISTANCE OF 23.53 FEET; THENCE N 45° 14' 30" W, A DISTANCE OF 92.94 FEET; THENCE S 89° 45' 30' W, A DISTANCE OF 35.04 FEET; THENCE N 00° 11' 47" E, A DISTANCE OF 23.92 FEET; THENCE ALONG THE ARC OF A 14.32 FOOT RADIUS CURVE TO THE RIGHT, A DISTANCE OF 9.62 FEET, THE LONG CHORD OF WHICH BEARS N 19° 26' 55" E A DISTANCE OF 9.44 FEET; THENCE N 38° 42' 03" E, A DISTANCE OF 9.52 FEET TO THE POINT OF BEGINNING; EXCEPT THAT PORTION CONVEYED IN DEED RECORDED NOVEMBER 20, 2012 AT RECEPTION NO. 20120082646 AND A PORTION OF TRACT NINE, THE FOOTHILLS FASHION MALL EXPANSION, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT WHICH BEARS N 89° 45' 30" E, 199.36 FEET AND AGAIN S 67° 44' 30" E, 268.90 FEET AND AGAIN S 45° 14' 30" E, 129.24 FEET AND AGAIN S 48° 48' 33" E, 49.58 FEET FROM THE EAST RADIUS POINT AT THE NW CORNER OF LOT 2, STRACHAN SUBDIVISION THIRD FILING AND RUN THENCE ALONG THE ARC OF A 398.41 FOOT RADIUS CURVE TO THE LEFT A DISTANCE OF 263.30 FEET, THE LONG CHORD OF WHICH BEARS S 71° 18' 34" E, 258.53 FEET; THENCE N 89° 45' 30" E 214.00 FEET; THENCE ALONG THE ARC OF A 15.00 FOOT RADIUS CURVE TO THE RIGHT A DISTANCE OF 23.56 FEET, THE LONG CHORD OF WHICH BEARS S 45° 14' 30" E, 21.21 FEET TO A POINT ON THE WEST LINE OF STANFORD ROAD; THENCE N 00° 14' 30" W, 49.00 FEET ALONG THE SAID WEST LINE; THENCE S 89° 45' 30" W, 229.09 FEET; THENCE ALONG THE ARC OF A 364.41 FOOT RADIUS CURVE TO THE RIGHT A DISTANCE OF 240.19 FEET, THE LONG CHORD OF WHICH BEARS N 71° 21' 49" W, 235.87 FEET; THENCE S 38° 42' 03" W, 34.01 FEET TO THE POINT OF BEGINNING. TOGEHTER WITH (PARCEL II) A PORTION OF LOT 3, STRACHAN SUBDIVISION, THIRD FILING, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE SW CORNER OF LOT 2, STRACHAN SUBDIVISION, THIRD FILING; THENCE N 85° 18' 00" E, ALONG THE SOUTH LINE OF SAID LOT 2 A DISTANCE OF 58.78 FEET; THENCE N 89° 45' 30" E, ALONG THE SOUTH LINE OF LOT 2, A DISTANCE OF 192.00 FEET; THENCE N 44° 45' 30" E, ALONG, THEN LEAVING THE EAST LINE OF SAID LOT 2, A DISTANCE OF 312.00 FEET; THENCE S 45° 14' 30" E, A DISTANCE OF 115.25 FEET; THENCE S 48° 48' 34" E, A DISTANCE OF 49.58 FEET; THENCE ALONG THE ARC OF A 398.41 FOOT RADIUS CURVE TO THE LEFT, A DISTANCE OF 263.29 FEET, THE LONG CHORD OF WHICH BEARS S 71° 18' 34" E, A DISTANCE OF 258.53 FEET; THENCE N 89° 45' 30" E, A DISTANCE OF 214.00 FEET; THENCE ALONG THE ARC OF A 15.00 FOOT RADIUS CURVE TO THE RIGHT A DISTANCE OF 23.56 FEET, THE LONG CHORD OF WHICH BEARS S 45° 14' 30" E, A DISTANCE OF 21.21 FEET TO A POINT ON THE WEST RIGHT OF WAY LINE OF STANFORD ROAD AND THE EAST LINE OF LOT 3, STRACHAN SUBDIVISION, THIRD FILING; THENCE ALONG SAID WEST RIGHT OF WAY LINE AND SAID EAST LOT LINE, S 00° 14' 30" E, A DISTANCE OF 175.05 FEET; THENCE LEAVING SAID EAST LOT LINE ALONG SAID WEST RIGHT OF WAY LINE AND THE ARC OF A 298.80 FOOT RADIUS CURVE TO THE RIGHT, A DISTANCE OF 198.17 FEET, THE LONG CHORD OF WHICH BEARS S 18° 45' 30" W, A DISTANCE OF 194.56 FEET TO THE POINT OF BEGINNING; THENCE CONTINUE ALONG SAID WEST RIGHT OF WAY LINE AND THE ARC OF A 376.80 FOOT RADIUS CURVE TO THE LEFT, A DISTANCE OF 14.91 FEET, THE LONG CHORD OF WHICH BEARS S 36° 37' 30" W, A DISTANCE OF 14.91 FEET; THENCE LEAVING SAID WEST RIGHT OF WAY LINE N 53° 45' 30" W, A DISTANCE OF 141.48 FEET; THENCE S 44° 45' 30" W, A DISTANCE OF 260.46 FEET; THENCE S 89° 45' 30" W, A DISTANCE OF 24.83 FEET; THENCE N 45° 14' 30" W, A DISTANCE OF 142.44 FEET; THENCE N 44° 45' 30" E, A DISTANCE OF 278.02 FEET; THENCE N 21° 11' 34" W, A DISTANCE OF 16.88 FEET; THENCE N 79° 18' 37" E, A DISTANCE OF 9.19 FEET; THENCE S 45° 17' 43" E, A DISTANCE OF 158.86 FEET; THENCE S 53° 17' 53" E, A DISTANCE OF 150.64 FEET TO THE POINT OF BEGINNING. containing 165,237 square feet or 3.793 acres, more or less. LEGAL DESCRIPTION SITE PLAN NOTES 1.THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2.REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3.REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4.ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5.ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6.AN ALTERNATIVE COMPLIANCE REQUEST FOR LAND USE CODE SECTION 3.2.2(K)(2) NON-RESIDENTIAL PARKING WAS APPROVED TO EXCEED THE MAXIMUM PARKING AND ALLOW 133 PARKING SPACES. 7.AN ALTERNATIVE COMPLIANCE REQUEST FOR LAND USE CODE SECTION 3.2.2(C)(4)(b) BICYCLE PARKING WAS APPROVED TO ALLOW 10 BICYCLE PARKING STALLS INSTEAD OF THE ONE SPACE PER BED AS REQUIRED. 8.ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 9.SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 10.FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 11.ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 12.ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 13.COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THE PROPERTY OWNER OR OWNER'S ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 14.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 15.FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND Revised November 12, 2015 3 LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. *ADDITIONAL STORIES ARE PERMITTED IN CERTAIN CASES PER LUC DIVISION 3.10.5(F)1 SHEET INDEX Sheet Number Sheet Title C COVER L1 TREE INVENTORY L2 SITE PLANL3 LANDSCAPE PLANL4 LANDSCAPE DETAILS RL RESIDENTIAL LOW DENSITY DISTRICT FOOTHILLS MALL BOLTZ MIDDLE SCHOOL STREET TREE NOTES 1.A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2.CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. 3.STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4.THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5.SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. L5 L6 COURTYARDS TREE PROTECTION DETAILS ARCHITECTURAL SHEETS Sheet Number Sheet Title A1 EXTERIOR ELEVATIONS A2 A3 DIGITAL MATERIAL BOARDA4 ELEVATION DETAILSA5 SHADOW STUDYA6 EXTERIOR ELEVATIONS PERSPECTIVE VIEWS P1.0 PHOTOMETRIC SITE PLAN P1.1 PHOTOMETRIC SITE PLAN CUT SHEETS ST S T S T STS T ST STS T S T S T ST S T S T S T S TSTSTSTSTST G CTVW W WWWWWWWWWWWWWWWWWWH YDW SS SS SS SS SS SS SS SS SS SS SS SS SS F O F O FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFOFOFOFOFOFOTTT T T T T T T T T T T VAULT ELEC D S SSSSSSDSTSTSTSTSTSTSTSTSTST VAULTCABLEx x x x xx x x x x x xxxx x x xx x xx xx x 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 48 47 46 34 35 36 37 43 42 41 44 45 38 39 40 STANFORD ROADMONROE DRIVE (PRIVATE STREET) GRAVEL PATH GRAVEL PATH EXISTING ATTACHED SIDEWALK FORT COLLINS MARRIOTT ON-STREET PARKING AREA EXISTING FENCE TO REMAIN 17'-0" 17'-0" 17'-0" DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: TREE INVENTORY Printed On: 4/19/2023 9:42 AM File Name: 1 TREE INVENTORY.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 ESL Fort Collins LLC Hunter MacLeod 1550 Market St, Suite 200 Denver, CO 80202 OWNER/APPLICANT TREE INVENTORY FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 NORTH 0 15 30 60 SCALE: 1"=30'-0" A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. FO G SD SS T UE W FIBER OPTIC UTILITY GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY TELEPHONE UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY VAULT ELEC T G ELEC EXISTING TREES STREET LIGHT FIRE HYDRANT TRANSFORMER ELECTRIC BOX ELECTRIC VAULT TELEPHONE PEDESTAL EXISTING SIGN INLET GRATE GAS METER x EXISTING FENCE LEGEND "NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. THE SURVEY SHALL BE SENT TO THE CITY ENVIRONMENTAL PLANNER. IF ACTIVE NESTS ARE FOUND, THE CITY WILL COORDINATE WITH RELEVANT STATE AND FEDERAL REPRESENTATIVES TO DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY." 1) REQUIRED TREE SIZES AND METHOD OF TRANSPLANT: CANOPY SHADE TREE: 2.0” CALIPER BALLED AND BURLAPPED EVERGREEN TREE: 6.0' HEIGHT BALLED AND BURLAPPED ORNAMENTAL TREE: 1.5” CALIPER BALLED AND BURLAPPED 2) REQUIRED MITIGATION TREE SIZES: CANOPY SHADE TREE: 2.0” CALIPER BALLED AND BURLAPPED EVERGREEN TREE: 8.0' HEIGHT BALLED AND BURLAPPED ORNAMENTAL TREE: 2.0” CALIPER BALLED AND BURLAPPED 3) TREE PROTECTION FENCE MAIN BE REMOVED TEMPORARILY AS NEEDED. TRUNK PROTECTION SHALL REMAIN IN PLACE. L1 OF 7 EXISTING TREES TO BE REMOVED x TREE PROTECTION FENCE NOTES #TYPE DBH CONDITION MITIGATION VALUE NOTES PRESERVE REMOVE REASON FOR REMOVAL NORTH SIDE OF SITE 1 HONEY LOCUST 21"FAIR +3 FORESTRY RECOMMENDS TO PRESERVE X 2 HONEY LOCUST 12"FAIR 1.5 PRUNE X 3 GREEN ASH 14"FAIR 1.5 X 4 3 STEM GREEN ASH 6-8"FAIR-1 X 5 3 STEM GREEN ASH 14"FAIR 1.5 X 6 HAWTHORN 11"FAIR 1.5 X ELECTRICAL TRANSFORMER 7 HAWTHORN 8"FAIR -1 X TRASH ENCLOSURE 8 HAWTHORN 8"FAIR 1 X 9 HAWTHORN 7"FAIR 1 X 10 HAWTHORN 15"FAIR 2 X 11 HAWTHORN 16"FAIR 2 X 12 HAWTHORN 13"FAIR 1.5 X 13 HAWTHORN 17"FAIR 2 X 14 HAWTHORN 17"FAIR 2 X 15 GREEN ASH 20"FAIR 2.5 X 16 AUSTRUAN PINE 21"FAIR 3 X 17 GREEN ASH 17"FAIR -2 X 18 AUSTRIAN PINE 23"FAIR 3 X 19 GREEN ASH 16"FAIR 2.5 X 20 AUSTRIAN PINE 26"FAIR -2.5 X 21 AUSTRIAN PINE 0 DEAD X 22 SPRUCE 21"FAIR +2.5 X 23 AUSTRIAN PINE 20"FAIR 2.5 X 24 PINE 10"FAIR +1.5 X PARKING LOT 25 GREEN ASH 13"FAIR 1.5 X 26 HAWTHORN 8"FAIR 1 X 27 HAWTHORN 10"FAIR 1 X 28 SPRUCE 16"FAIR +2 X 29 SPRUCE 16"FAIR 2 X 30 SPRUCE 16"FAIR 1.5 X 31 HAWTHORN 11'FAIR 1 X STORM DRAIN PIPE 32 HAWTHORN 10 FAIR 1 X ACCESSIBLE RAMP 33 GREEN ASH 13"FAIR 1.5 X 34 GREEN ASH 10"FAIR -1 X 35 GREEN ASH 9"FAIR -1 X 36 GREEN ASH 9"FAIR-1 X 37 GREEN ASH 7"FAIR -1 X 38 GREEN ASH 12"FAIR -1.5 X 39 GREEN ASH 11"FAIR-1.5 X 40 GREEN ASH 8"FAIR-1 X 41 GREEN ASH 10"FAIR -1.5 X 42 GREEN ASH 13"FAIR 1.5 X 43 GREEN ASH 9"FAIR -1.5 X 44 CRABAPPLE 8"POOR 1 X 45 CRABAPPLE 11"FAIR -1 X 46 GREEN ASH 6"POOR 1 X 47 GREEN ASH 8"FAIR -1 X 48 GREEN ASH 8"FAIR -1 X TOTAL TREES TO BE MITIGATED 4.5 TREE INVENTORY CHART DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: TREE PROTECTION DETAILS Printed On: 4/19/2023 9:43 AM File Name: 2 TREE PROTECTION DETAILS.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 TREE PROTECTION DETAILS FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 L2 OF 7 NORTH 0 05 10 20 SCALE: 1"=10'-0" TREE PROTECTION FENCE SCALE: NTS LOWER CANOPY - CONTACT THE CITY FORESTER IF POTENTIAL FOR DAMAGE EXISTS AND/OR IF PRUNING, INCLUDING BUT NOT LIMITED TO CLEARANCE FOR BUILDING(S) AND/OR CONSTRUCTION SCAFFOLDING, IS NEEDED. CHAIN LINK FENCE (OPTIONAL) NOTES 1.DAMAGE TO PROTECTED TREES IS SUBJECT TO PENALTY PER CITY ORDINANCE. 2.TREE PROTECTION SHALL BE INSTALLED PRIOR TO COMMENCEMENT OF DEMOLITION/CONSTRUCTION ACTIVITIES AND MAY ONLY BE REMOVED TEMPORARILY IF TRUNK PROTECTION IS INSTALLED. IT SHALL REMAIN IN PLACE UNTIL CERTIFICATE OF OCCUPANCY IS ISSUED. 3.NO MATERIALS, DEBRIS, EQUIPMENT, OR SITE AMENITIES SHALL BE STORED WITHIN THE TREE PROTECTION FENCE. 4.WHILE TREE PROTECTION FENCING IS IN PLACE, TREES SHALL BE DEEP-ROOT WATERED AT AN INTERVAL OF ONCE PER WEEK WHEN TEMPERATURES ARE AT OR ABOVE 50-DEGREES F. TREES SHALL BE WATERED AT THE RATE OF 10 GALLONS PER INCH CALIPER. 5.TREE PROTECTION FENCING SHALL BE "ORANGE PLASTIC SAFETY FENCING," MIN. 48" IN HEIGHT, TOP SECURED TO METAL T-POSTS WITH 12-GAUGE WIRE WOVEN THROUGH TOP OF FENCING FOR ENTIRE LENGTH. -HEAVY DUTY T-POSTS SHALL BE PLACED SO THAT WIRE & FENCE ARE TAUT. -CHAIN LINK FENCING IS RECOMMENDED. 6. TRUNK PROTECTION IS REQUIRED IF CONSTRUCTION OCCURS WITHIN TEN FEET OR LESS OF TRUNK. CONSTRUCTION INSIDE CRITICAL ROOT ZONE IS ONLY PERMITTED WHEN EQUIPMENT IS OPERATED EXCLUSIVELY ON EXISTING HARDSCAPE, AND NO SOIL COMPACTION TAKES PLACE. DBH X 12" OR AS APPROVED METAL "T" POST TRUNK PROTECTION CRITICAL ROOT ZONE DETAIL-FILE 1 TREE PROTECTION NOTES TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. TREE MITIGATION SUMMARY TABLE TREE MITIGATION NOTES 1.SHOULD DISCREPANCIES BE FOUND BETWEEN THE QUANTITIES LISTED IN THE PLANT TABLE AND THE QUANTITIES GRAPHICALLY SHOWN ON THE LANDSCAPE PLANS, THEN THE QUANTITIES SHOWN BY GRAPHIC SYMBOLS ON THE LANDSCAPE PLANS SHALL CONTROL 2.ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR A NESTING SURVEY WILL BE CONDUCTED BY A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST PRIOR TO TREE REMOVAL TO ENSURE THAT NO ACTIVE NESTS ARE PRESENT. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. MITIGATION TREES REQUIRED MITIGATION TREES PROVIDED MITIGATION SHRUBS REQUIRED MITIGATION SHRUBS PROVIDED 4.5 5 0 0 *TREE MITIGATION LOCATIONS CAN BE FOUND ON THE LANDSCAPE PLAN AND LANDSCAPE PLAN (L4 ). MITIGATION TREES ARE LOCATED WITH AN "M" (SEE PLAN LEGENDS FOR ICON). TYPE MINIMUM SIZE CANOPY SHADE TREE 2.0" CALIPER AND BALLED AND BURLAPPED EVERGREEN TREE 8.0" HEIGHT AND BALLED AND BURLAPPED ORNAMENTAL TREE 2.0" CALIPER AND BALLED AND BURLAPPED MITIGATION TREE SIZE CHART A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. TFVAULTCABLEVAULTELECELECVAULTVAULTELECUD UDEEEEEEE E TTT T G G G GUDUD UD U D U D E E ETFE E E ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST S T S T S T S T EEEEEEEEEEEEEEEEE E E E EEEEEEEEEE E E E E E E EGGCTVCTVWWW WWWWWWWWWWWWWWWWWH YDWSS SS SS SS SS SS SS SS SS SS SS SS FO FO FO FO FO FO FO FO FO FO FO FOFO FO FO FO FOFOFOFOFOFOFOFOFOFOFOFOFOFOT T T T T T TTTTTT T VAUL T ELE C D SSSSSSSSSSDSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T S T S T S T S T S T S T STST EEEEEEEEEEE E E E EEEEE E ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST S T S T S T S T EEEEEEEEEEEEEEEEE E E E EEEEEEEEEE E E E E E E EGGCTVCTVWWW WWWWWWWWWWWWWWWWWH YDWSS SS SS SS SS SS SS SS SS SS SS SS FO FO FO FO FO FO FO FO FO FO FO FOFO FO FO FO FOFOFOFOFOFOFOFOFOFOFOFOFOFOT T T T T T TTTTTT T VAUL T ELE C D SSSSSSSSSSDSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T S T S T S T S T S T S T STST EEEEEEEEEEE E E E EEEEE E 94 34 FOFOFOFOFOFOFOFOFOFOFOFO FOFO FO SS SS SS SS D VAULTELECVAULTELE C ELECT SVAULTF.O.W W W W UDEEEEEEEEEEEGGGGGGGGGGG GG TTWWWWWWWWWWWWWWWWWWW W WW W WW WGGGEEE10 01 HARDSCAPE SYMBOL DESCRIPTION QTY DETAIL CONCRETE 8,946 SF 20 SITE DEVELOPMENT SYMBOL DESCRIPTION QTY DETAIL DRIVES AND PARKING 13,032 SF REFERENCE NOTES SCHEDULE EXISTING DRIVEWAY S T A N FO R D RO A D ( 7 8 ' ROW ) MON R O E D RI V E (PRI V AT E ST R E ET) PRIVATE COURTYARD (4243 SF) DROP-OFF LANE MAIN ENTRY PARKING SPACES IN GARAGE BELOW SERVICE DRIVE EXISTING TREES TO REMAIN 6'-6" EXISTING 6'-0" SIDEWALK TO REMAIN EXISTING LIGHT POLES TO REMAIN, TYP. 37'-0" RAMP, REF. CIVIL, TYP. PARKING SPACES RAMP, REF. CIVIL, TYP. LANDSCAPE ISLANDS TO REMAIN, TYP. PATIO REF. CIVIL FOR UNDERGROUND STORM CHAMBERS BICYCLE PARKING SPACES IN GARAGE 6' TALL FENCE ON WALL BUILDING OVERHANG, TYP. EXISTING ROW DEDICATED ROW AT BACK OF WALK EXISTING CURB CYCLE APARTMENTS ASPENLEAF APARTMENTS FORT COLLINS MARRIOTT GARAGE ACCESS ACCESS TO COURTYARD, TYP. TRASH AND RECYCLING ENCLOSURE SUBTERRANEAN GARAGE LIMITS EXTENTS OF TWO-STORY ROOF 30'-0" ELECTRICAL TRANSFORMERS ROOFTOP TERRACE AND GARDEN BEDS LIT BOLLARDS, BEGA, LED GARDEN AND PATHWAY BOLLARD - 77265, BRONZE COLOR 8'-0" TREE LAWN BUILDING COLUMN DRAINAGE EASEMENT EMERGENCY ACCESS EASEMENT MONUMENT SIGN 4-STORY BUILDING LONG-TERM CARE FACILITY 18'-0" 30'-0" STAIRS 5' WIDE SIDEWALK 8' WIDE TREE LAWN PRIVATE COURTYARD (7172 SF) EV VILLAGE CO-OP BOULDERS SET IN SLOPE EVEVEV LOCATION OF FUTURE EV PEDESTALS 01 HARDSCAPE SYMBOL DESCRIPTION QTY DETAIL CONCRETE 8,946 SF 20 SITE DEVELOPMENT SYMBOL DESCRIPTION QTY DETAIL DRIVES AND PARKING 13,032 SF DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: SITE PLAN Printed On: 4/19/2023 9:43 AM File Name: 2 SITE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 ESL Fort Collins LLC Hunter MacLeod 1550 Market St, Suite 200 Denver, CO 80202 OWNER/APPLICANT SITE PLAN FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 L3 OF 7 NORTH 0 15 30 60 SCALE: 1"=30'-0" FO G SD SS T UE W FIBER OPTIC UTILITY GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY TELEPHONE UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY VAULT ELEC T G ELEC EXISITING TREES TO REMAIN (SEE INVENTORY AND MITIGATION PLAN, SHEET L1) STREET LIGHT FIRE HYDRANT TRANSFORMER ELECTRIC BOX ELECTRIC VAULT TELEPHONE PEDESTAL EXISTING SIGN INLET GRATE GAS METER x EXISTING FENCE PROPOSED FENCE LEGEND A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. NOTE: CONTRACTOR TO VERIFY QUANTITIES FOR ALL BID ITEMS EV ELECTRIC VEHICLE-READY PARKING STALL TFVAULTCABLEVAULTELECELECVAULTVAULTELECUD UDEEEEEEE E TTT T G G G GUDUD UD UDU D E E ETFE E E STSTSTSTSTSTSTSTSTSTSTSTS T S T S T S T EEEEEEEEEEEEEEEEE E E E EEEEEEEEE E E E E E E EG CTVWWW WWWWWWWWWWWWWWWWWH YDWSS SS SS SS SS SS SS SS SS SS SS FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFOFOFOFOFOFOFOT T T T T T TTTTTT T VAULTELECDSSSSSSSSSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T S T S T S T S T S T S T EEEEEEEEEEE E E E EEE EEESTSTSTSTSTSTSTSTSTSTSTSTS T S T S T S T EEEEEEEEEEEEEEEEE E E E EEEEEEEEE E E E E E E EG CTVWWW WWWWWWWWWWWWWWWWWH YDWSS SS SS SS SS SS SS SS SS SS SS FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFOFOFOFOFOFOFOT T T T T T TTTTTT T VAULTELECDSSSSSSSSSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T S T S T S T S T S T S T EEEEEEEEEEE E E E EEE EEE94 3 - UFR 5 - MA 3 - NWL 8 - AVS BGB - 20 NWL - 5 MA - 5 RFO - 17 AAC - 6 6 - PMB 3 - UFR 8 - RTA HME - 5 CSA - 10 HME - 5 CDI - 4 MSP - 1 PPA - 1 CDI - 6 CSA - 5 3 - QSS 3 - GAT 3 - ACP RFO - 9 MA - 3 NWL - 7 15 - BGB 13 - RTA 2 - GDE 5 - MA 6 - NWL 8 - AVS 5 - MA UFR - 1 RFO - 5 AMO - 7 PPA - 2 ACP - 2 MA - 3 CSA - 4 HME - 3 6 - NWL ACP - 3 NWL - 5 NWL - 6 2 - CDI 8 - HME 6 - CDI 12 - HME 5 - JSU 4 - CAI 4 - PMB 5 - RTA 3 - PMB 4 - JSU 7 - CSI 9 - RTA 6 - PMB 16 - AAC 3 - PES 5 - CSI 6 - BGB 7 - AMO 5 - RFO 6 - CDI 6 - MA 14 - BGB 12 - AMO 8 - DB 5 - JS SHEET L6 SHEET L6 SHEET L6 13 - RFO 3 - MRB 7 - RMS 9 - NWL 8 - RFO 4 - ACP 22 - RFO 2 - COP 3 - JSS 4 - HME 3 - CAI 9 - RMS 6 - NWL 8 - MA 4 - HME 25 - RTA 5 - CAI 1 - COP 9 - AVS 4 - CSA 2 - PPA 14 - MA 3 - ACP 1 - MSP 6 - RMS 4 - CSA 3 - ATH 3 - AMO 17 - AMO EXISTING PARKING SPACES M M EXISTING DRIVEWAY S T A N FO R D RO A D ( 7 8 ' ROW ) MON R O E D RI V E (PRI V AT E ST R E ET) DROP-OFF LANE MAIN ENTRY SERVICE DRIVE M BUILDING OVERHANG, TYP. EXISTING TREES TO REMAIN EXISTING CURB RAMP, REF. CIVIL, TYP. RAMP, REF. CIVIL, TYP. LANDSCAPE ISLANDS TO REMAIN, TYP. EXISTING FENCE 5' DETACHED WALK 6' ATTACHED WALK EXISTING TREES M M INSTALL TURF TO LIMITS OF DISTURBANCE LIGHT POLE, TYP. TRANSFORMERS TRASH ENCLOSURE MONUMENT SIGN REFERENCE ARCHITECTURAL PATIO ALUMINUM DOGIPOT PET STATION #1003-L LOCATION OF FUTURE EV PEDESTALS TREES COMMON NAME ATH HOT WINGS MAPLE COP PRAIRIE SENTINEL HACKBERRY GAT SKYLINE HONEY LOCUST GDE SEEDLESS KENTUCKY COFFEETREE JSS ROCKY MOUNTAIN JUNIPER MSP SPRING SNOW CRAB APPLE MRB RED BARRON CRAB APPLE PPA BAKERI SPRUCE PB BRISTLECONE PINE PES PINYON PINE PT QUAKING ASPEN QSS SHUMARD RED OAK SRE JAPANESE LILAC TREE UFR FRONTIER ELM SHRUBS COMMON NAME AO STANDING OVATION SERVICEBERRY ACP PANCHITO MANZANITA BTA CRIMSON PYGMY BARBERRY BT ORANGE ROCKET JAPANESE BARBERRY BM GREEN TOWER COMMON BOXWOOD CM MOUNTAIN MAHOGANY CAI IVORY HALO VARIEGATED DOGWOOD CSA ARCTIC FIRE RED TWIG DOGWOOD CSI ISANTI RED TWIG DOGWOOD CDI SPREADING COTONEASTER DBB BRIGGS MOONLIGHT DAPHNE DB CAROL MACKIE DAPHNE EC CHOLLIPO JAPANESE EUONYMUS HME ENDLESS SUMMER HYDRANGEA JSU BUFFALO JUNIPER JS MEDORA JUNIPER MA COMPACT OREGON GRAPE MRE CREEPING COLORADO HOLLY PMB BIG TUNA MUGO PINE RC CUNNINGHAM'S WHITE RHODODENDRON RTA SKUNKBUSH SUMAC RMS MORDEN SUNRISE SHRUB ROSE ORNAMENTAL GRASSES COMMON NAME BGB BLONDE AMBITION GRAMA GRASS CAK FEATHER REED GRASS IR JAPANESE BLOOD GRASS PERENNIALS COMMON NAME AMO MOONSHINE YARROW AAC CORONADO HYSSOP AC2 NODDING ONION AC ROCKY MOUNTAIN COLUMBINE AVS SEAFOAM SAGE EPU PURPLE CONEFLOWER GO SWEET WOODRUFF HP PALACE PURPLE CREVICE ALUMROOT HSS VARIEGATED CORAL BELLS MO LEMON BALM NWL WALKERS LOW CATMINT RFO BLACK-EYED SUSAN 02 LANDSCAPE MATERIAL SYMBOL DESCRIPTION STEEL EDGER 01 HARDSCAPE SYMBOL DESCRIPTION CONCRETE 02 LANDSCAPE MATERIAL SYMBOL DESCRIPTION IRRIGATED TURF COBBLE MULCH RIVER COBBLE WOOD MULCH 20 SITE DEVELOPMENT SYMBOL DESCRIPTION DRIVES AND PARKING DECIDUOUS CANOPY TREES DECIDUOUS ORNAMENTAL TREES EVERGREEN TREES EXISTING DECIDUOUS TREES EXISTING EVERGREEN TREES EVERGREEN SHRUBS TREE FOR MITIGATION DECIDUOUS CANOPY TREES DECIDUOUS ORNAMENTAL TREES EVERGREEN TREES EXISTING DECIDUOUS TREES EXISTING EVERGREEN TREES EVERGREEN SHRUBS TREE FOR MITIGATION DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: LANDSCAPE PLAN Printed On: 4/19/2023 9:43 AM File Name: 3 LANDSCAPE PLAN.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 LANDSCAPE PLAN FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 L4 OF 7 NORTH 0 15 30 60 SCALE: 1"=30'-0" PLANT MATERIAL LEGEND LANDSCAPE MATERIAL LEGEND PLANT SYMBOL LEGEND A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. SEE SHEET L5 FOR FULL PLANT SCHEDULE FO G SD SS T UE W FIBER OPTIC UTILITY GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY TELEPHONE UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY x EXISTING FENCE PROPOSED FENCE UFR TREES QTY BOTANICAL / COMMON NAME CONT CAL SIZE % DIVERSITY ATH 4 ACER TATARICUM `HOT WINGS` / HOT WINGS MAPLE B & B 2"8% COP 3 CELTIS OCCIDENTALIS `PRAIRIE SENTINEL` / PRAIRIE SENTINEL HACKBERRY B & B 2.5"6% GAT 3 GLEDITSIA TRIACANTHOS `SKYLINE` / SKYLINE HONEY LOCUST B & B 2.5"6% GDE 2 GYMNOCLADUS DIOICA `ESPRESSO` / SEEDLESS KENTUCKY COFFEETREE B & B 2.5"4% JSS 3 JUNIPERUS SCOPULORUM / ROCKY MOUNTAIN JUNIPER B & B 6` HT 6% MSP 2 MALUS `SPRING SNOW` / SPRING SNOW CRAB APPLE B & B 2"4% MRB 3 MALUS X `RED BARRON` / RED BARRON CRAB APPLE B & B 2"6% PPA 5 PICEA PUNGENS `BAKERI` / BAKERI SPRUCE B & B 6` HT 10% PB 2 PINUS ARISTATA / BRISTLECONE PINE B & B 6` HT.4% PES 3 PINUS EDULIS / PINYON PINE B & B 6` HT 6% PT 3 POPULUS TREMULOIDES / QUAKING ASPEN B & B 2"6% QSS 3 QUERCUS SHUMARDII / SHUMARD RED OAK B & B 2.5"6% SRE 5 SYRINGA RETICULATA / JAPANESE LILAC TREE B & B 2"CAL 10% UFR 7 ULMUS `FRONTIER` / FRONTIER ELM B & B 2.5"15% 48 TOTAL TREES SHRUBS QTY BOTANICAL / COMMON NAME SIZE HYDROZONE AO 3 AMELANCHIER ALNIFOLIA 'OBELISK' TM / STANDING OVATION SERVICEBERRY 5 GAL ACP 15 ARCTOSTAPHYLOS X COLORADOENSIS `PANCHITO` / PANCHITO MANZANITA 5 GAL BTA 6 BERBERIS THUNBERGII `CRIMSON PYGMY` / CRIMSON PYGMY BARBERRY 5 GAL BT 14 BERBERIS THUNBERGII 'ORANGE ROCKET' / ORANGE ROCKET JAPANESE BARBERRY 5 GAL BM 20 BUXUS SEMPERVIRENS 'MONRUE' TM / GREEN TOWER COMMON BOXWOOD 5 GAL CM 5 CERCOCARPUS MONTANUS MONTANUS / MOUNTAIN MAHOGANY 5 GAL CAI 12 CORNUS ALBA `IVORY HALO` / IVORY HALO VARIEGATED DOGWOOD 5 GAL CSA 27 CORNUS SERICEA `ARCHTIC FIRE` / ARCTIC FIRE RED TWIG DOGWOOD 5 GAL CSI 12 CORNUS SERICEA `ISANTI` / ISANTI RED TWIG DOGWOOD 5 GAL CDI 24 COTONEASTER DIVARICATUS / SPREADING COTONEASTER 5 GAL DBB 24 DAPHNE X BURKWOODII 'BRIGGS MOONLIGHT' / BRIGGS MOONLIGHT DAPHNE 5 GAL DB 20 DAPHNE X BURKWOODII 'CAROL MACKIE' / CAROL MACKIE DAPHNE 5 GAL EC 5 EUONYMUS JAPONICUS 'CHOLLIPO' / CHOLLIPO JAPANESE EUONYMUS 5 GAL HME 41 HYDRANGEA MACROPHYLLA `ENDLESS SUMMER` / ENDLESS SUMMER HYDRANGEA 5 GAL JSU 9 JUNIPERUS SABINA `BUFFALO` / BUFFALO JUNIPER 5 GAL JS 5 JUNIPERUS SCOPULORUM 'MEDORA' / MEDORA JUNIPER 5 GAL MA 54 MAHONIA AQUIFOLIUM 'COMPACTA' / COMPACT OREGON GRAPE 5 GAL MRE 16 MAHONIA REPENS / CREEPING COLORADO HOLLY 5 GAL PMB 30 PINUS MUGO `BIG TUNA` / BIG TUNA MUGO PINE 10 GAL - RC 3 RHODODENDRON X 'CUNNINGHAM'S WHITE' / CUNNINGHAM'S WHITE RHODODENDRON 1 GAL RTA 60 RHUS TRILOBATA `GRO LOW` / SKUNKBUSH SUMAC 5 GAL RMS 22 ROSA SHRUB `MORDEN SUNRISE` / MORDEN SUNRISE SHRUB ROSE 5 GAL 427 TOTAL SHRUBS ORNAMENTAL GRASSES QTY BOTANICAL / COMMON NAME SIZE HYDROZONE BGB 70 BOUTELOUA GRACILIS `BLONDE AMBITION` / BLONDE AMBITION GRAMA GRASS 1 GAL CAK 60 CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER` / FEATHER REED GRASS 1 GAL IR 69 IMPERATA CYLINDRICA 'RED BARON' / JAPANESE BLOOD GRASS 1 GAL 199 PERENNIALS QTY BOTANICAL / COMMON NAME SIZE HYDROZONE AMO 51 ACHILLEA X `MOONSHINE` / MOONSHINE YARROW 1 GAL AAC 37 AGASTACHE AURANTIACA `CORONADO` / CORONADO HYSSOP 1 GAL AC2 36 ALLIUM CERNUUM / NODDING ONION 4" POT AC 26 AQUILEGIA CAERULEA / ROCKY MOUNTAIN COLUMBINE 1 GAL AVS 25 ARTEMISIA VERSICOLOR `SEA FOAM` / SEAFOAM SAGE 1 GAL EPU 5 ECHINACEA PURPUREA / PURPLE CONEFLOWER 1 GAL GO 28 GALIUM ODORATUM / SWEET WOODRUFF 1 GAL HP 9 HEUCHERA MICRANTHA 'PALACE PURPLE' / PALACE PURPLE CREVICE ALUMROOT 1 GAL HSS 18 HEUCHERA SANGUINEA `SNOW ANGEL` / VARIEGATED CORAL BELLS 1 GAL MO 10 MELISSA OFFICINALIS / LEMON BALM 4" POT NWL 53 NEPETA X FAASSENII `WALKERS LOW` / WALKERS LOW CATMINT 1 GAL RFO 79 RUDBECKIA FULGIDA `GOLDSTURM` / BLACK-EYED SUSAN 1 GAL 377 DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: LANDSCAPE DETAILS Printed On: 4/19/2023 9:43 AM File Name: 4 LANDSCAPE DETAILS.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 ESL Fort Collins LLC Hunter MacLeod 1550 Market St, Suite 200 Denver, CO 80202 OWNER/APPLICANT LANDSCAPE DETAILS FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 L5 OF 7 PR E V A I L I NG W I ND PLAN VIEW - THREE STAKES TREE PLANTING DETAIL - STEEL POSTS SCALE: NTS ROUND TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. (OMIT IN TURF AREAS) NOTES: SET S0 THAT TOP OF ROOT 1-2" HIGHER THAN FINISHED GRADE MARK NORTH SIDE OF TREE IN NURSERY AND ROTATE TREE TO FACE NORTH AT THE SITE WHENEVER POSSIBLE 2 STRAND 12 GAUGE GAL. WIRE (TWIST TO TIGHTEN) & GROMMETED NYLON STRAPS STEEL T-POSTS DRIVEN (MIN. 24") FIRMLY INTO UNDISTURBED SOIL OUTSIDE OF PLANTING HOLE BEFORE BACKFILLING STAKE ABOVE FIRST BRANCHES OR AS NECESSARY FOR FIRM SUPPORT BACKFILL WITH BLEND OF EXISTING SOIL AND A MAXIMUM 20% (BY VOL.) ORGANIC MATERIAL PLACE FIRMLY BUT DON'T TAMP OR COMPACT AROUND ROOT BALL. WATER WATER THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. REMOVE ALL WIRE, TWINE BURLAP, MESH AND CONTAINERS FROM ENTIRE ROOT BALL AND TRUNK 3" DEEP MULCH RING PLACED A MINIMUM OF 6' IN DIAMETER. 1" MULCH OVER ROOT BALL. DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK 3 X BALL DIA. BOTTOM OF ROOT BALL RESTS ON EXISTING OR RECOMPACTED SOIL SCARIFY SIDES OF HOLE LEAVING 1:1 SLOPE 1 L-PL2-PLA-12 STAKING NOTES: STAKE TREES PER FOLLOWING SCHEDULE, THEN REMOVE AT END OF FIRST GROWING SEASON AS FOLLOWS: 1 1/2" CALIPER SIZE - MIN. 1 STAKE ON SIDE OF PREVAILING WIND. (GENERALLY N.W. SIDE) 1 1/2" - 3" CALIPER SIZE - MIN. 2 STAKES - ONE ON N.W. SIDE, ONE ON S.W. SIDE 3" CALIPER SIZE AND LARGER - 3 STAKES PER DIAGRAM WIRE OR CABLE SHALL BE MIN. 12 GAUGE, TIGHTEN ONLY ENOUGH TO KEEP FROM SLIPPING. ALLOW FOR SOME TRUNK MOVEMENT. NYLON STRAPS SHALL BE LONG ENOUGH TO ACCOMMODATE 1 1/2" OF GROWTH AND BUFFER ALL BRANCHES FROM WIRE GUYING PLAN PLANT SO THAT TOP OF ROOT BALL IS 2" HIGHER THAN FINISHED GRADE GROMMETED NYLON STRAPS GALVANIZED WIRE TWIST TO TIGHTEN 6' STEEL T-POSTS (SEE SCHEDULE) DRIVEN (MIN. 24") FIRMLY INTO UNDISTURBED SOIL OUTSIDE ROOTBALL. SCARIFY SIDES OF PLANTING HOLE LEAVING 1:1 SLOPE BACKFILL WITH BLEND OF EXISTING SOIL AND A MAXIMUM 20% (BY VOL.) ORGANIC MATERIAL TAMP SOIL AROUND ROOT BALL W/ FOOT PRESSURE SO THAT IT DOESN'T SHIFT. WATER THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE TREE. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. PRUNING NOTES: DO NOT HEAVILY PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS AND BROKEN BRANCHES. SOME INTERIOR TWIGS AND LATERAL BRANCHES MAY BE PRUNED. HOWEVER, DO NOT REMOVE THE TERMINAL BUDS OF BRANCHES THAT EXTEND TO THE EDGE OF THE CROWN 3 X BALL DIA. P R E V A I L ING W IN D 3" DEEP MULCH RING PLACED A MINIMUM OF 6' IN DIAMETER. DO NOT PLACE MULCH IN CONTACT WITH TREE TRUNK ROUND-TOPPED SOIL BERM 4" HIGH X 8" WIDE ABOVE ROOT BALL SURFACE SHALL BE CONSTRUCTED AROUND THE ROOT BALL. BERM SHALL BEGIN AT ROOT BALL PERIPHERY. (OMIT IN TURF AREAS) CONIFER TREE PLANTING DETAIL - STEEL POSTS SCALE: NTS REMOVE ALL WIRE, TWINE BURLAP, MESH AND CONTAINERS FROM ENTIRE ROOT BALL AND TRUNK 2 L-PL2-PLA-01 PRUNING NOTES: DO NOT HEAVILY PRUNE SHRUB AT PLANTING. PRUNE ONLY DEAD OR BROKEN BRANCHES. IF FORM IS COMPROMISED BY PRUNING, REPLACE SHRUB PLACEMENT NOTES: ·SET SHRUB PLUMB. SPACE PLANTS, AND PLACE FOR BEST EFFECT ·SET TOP OF ROOTBALL 1-2" HIGHER THAN ADJACENT GRADE SCARIFY SIDES AND USE 1:1 SLOPE 3" DEEP MULCH RING 3' IN DIA. PLACE ON GEOTEXTILE WEED BARRIER. 1" OF MULCH ON TOP OF ROOT BALL REMOVE CONTAINER (INCLUDING FIBER CONTAINERS), BASKETS, WIRE, ETC. FROM THE ROOT BALL. BREAK UP ENCIRCLING ROOTS WITH SHARP KNIFE OR SPADE. SPLIT BOTTOM OF ROOT BALL. PLACE ON UNDISTURBED SOIL TO PREVENT SETTLEMENT. PRIOR TO MULCHING, LIGHTLY TAMP SOIL AROUND THE ROOT BALL IN 6" LIFTS TO BRACE SHRUB. DO NOT OVER COMPACT. WHEN THE PLANTING HOLE HAS BEEN BACKFILLED, POUR WATER AROUND THE ROOT BALL TO SETTLE THE SOIL. BACKFILL WITH BLEND OF EXISTING SOIL AND A MAX. 20% (BY VOL.) ORGANIC MATERIAL. WATER THOROUGHLY TO SETTLE AND REMOVE AIR POCKETS 2 X BALL DIA. 4" HIGH WATER SAUCER SHRUB PLANTING DETAIL SCALE: NTS 3 L-PL2-PLA-14 1.PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT. 2.IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. 3.TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4.SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOROUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5.INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6.MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7.REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8.THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS 15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES 4 FEET BETWEEN TREES AND GAS LINES 9.ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). 10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN. 11.THE DEVELOPER SHALL ENSURE THAT THE FINAL LANDSCAPE PLAN IS COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN. 12.MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION. 13.ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES. 14.IRRIGATED TURF SHALL BE RYIZOMATOUS 90-10 FESCUE BLEND BY TURF MASTER, LLC OR APPROVED EQUAL. 15.EDGING BETWEEN GRASS AND SHRUB BEDS SHALL BE 18" X 4" ROLLED TOP STEEL SET LEVEL WITH TOP OF SOD OR APPROVED EQUAL. 16.THE DEVELOPER SHALL ENSURE THAT THE FINAL LANDSCAPE PLAN COMPLIES WITH IFC 317, ESTABLISHED MAINTENANCE PLAN, THE INSTALLATION OF IRRIGATION, AND THE ONGOING REMOVAL OF DEAD FOLIAGE. GENERAL LANDSCAPE NOTES HYDROZONE AREA (SF)WATER NEEDED (GALLONS/SF)ANNUAL WATER USE (GALLONS) HIGH 19797.00 18 356,346.00 MODERATE 15310.00 10 153,100.00 LOW 0.00 3 0.00 VERY LOW 960.00 0 0.00 TOTAL 36,067 14.1250 509,446 ANNUAL WATER USE NOT TO EXCEED 15 GAL./SF. AVERAGE OVER THE SITE WATER USE TABLE A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 8' PRIVACY FENCE001.FENCE WILL BE COMPOSITE OR PAINTED/STAINED WOOD WITH HORIZONTAL OR VERTICAL SLATS. FINISH COLOR OF FENCE IS INTENDED TO COMPLIMENT THE SIDING MATERIAL ON THE BUILDING, HOWEVER, MAY NOT BE AN EXACT MATCH. 2.FENCE IS LOCATED ON THE WALL AROUND THE PERIMETER OF THE MEMORY CARE GARDEN AS SHOWN ON PLANS. 3.SEE GRADING PLAN FOR WALL HEIGHT. PER CITY OF FORT COLLINS 3.2.1(D)3 PROPOSED PLAN MUST HAVE A SPECIES DIVERSITY OF (10-19 TREES > 50%, 20-39 TREES > 33%, 40-59 TREES > 25%, 60+ TREES > 15%). OF THE 84 TOTAL TREES SURVEYED AND PROPOSED ON SITE, NO SPECIES MAY HAVE MORE THAN 12 QUANTITY. UD UD UD UDUD UD UDUD UD U D UDU D U D UDU D U D UDEEEEEEEFOFO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFOTTTTTTTTTT T EEEEEEEEEEEEEEEEEEEEEEEEFOFO FO FO FO FO FO FO FO FOFOFOFOFOFOFOFOTTTTTTTTTT T EEEEEEEEEEEEEEEEE8 - HSS 8 - BM 5 - AMO 4 - BGB 5 - EPU 3 - BTA 5 - AAC 5 - BGB 3 - MO 5 - DBB 6 - MRE 8 - GO 3 - DB 5 - MRE 6 - HP 7 - BM 3 - DB 6 - GO 5 - MRE 6 - GO 5 - BM 2 - PB 3 - AO 1 - SRE 5 - DBB 7 - MO 3 - BGB 3 - AAC 3 - BGB 3 - BTA 6 - DB 10 - HSS 1 - SRE 8 - GO 3 - RC 3 - HP 15 - CAK S T A N FO R D RO A D ORNAMENTAL METAL FENCE, SEE SHEET L5 S T A N FO R D RO A D MON R OE D RIVE LEAF TOWER BRASS BOLLARD LIGHT, VOLTLIGHTING.COM RE: ELEC. EMERGENCY EGRESS GATE AND STEPS STEPS AND RAILING RE: ARCH RETAINING WALL WITH 6' FENCE SEE CIVIL FOR GRADES STANDARD GRAY CONCRETE SAWCUT SCORE JOINTS, MEDIUM BROOM FINISH (3) RAISED GARDEN BEDS GG 5'-0" 5'-0" 24'-0" 5'-0"FOFOFOFOEEFOFOFOFOEE3 - CAK 3 - CAK 3 - CAK4 - CAK 8 - CAK 8 - CAK8 - CAK 8 - CAK UPUP RAISED GARDEN BEDS 140 GAL. GARDEN TOOL STORAGE. RUBBERMAID OR APPROVED EQUAL. WOOD PAVER RE: ARCH ALL FURNITURE BY OWNER DOOR FLUSH PLANTER W / WATERPROOF LINER. PLANTERWORX OR APPROVED EQUAL. PROVIDE HOSE BIB FOR HAND WATERING 5 - EC 1 - ATH 6 - DBB 3 - PT 12 - AC2 5 - PMB 4 - DBB 5 - CM 10 - AC 7 - IR 5 - PMB 4 - DBB 24 - AC2 3 - SRE 3 - BT 16 - AC 7 - AAC 2 - BT 1 - PMB 3 - BT 6 - BT 19 - IR 5 - IR 3 - IR 9 - IR 14 - IR 6 - IR 6 - IR BUILDING OVERHANG, TYP. HENRI STUDIO EQUILIBRIA OUTDOOR FOUNTAIN, HAYNEEDLE.COM PERGOLA SEATING AT STUCCO GARDEN WALL ACCESS TO COURTYARD, TYP. STONE VENEER GAS FIRE PIT SEATING AT STUCCO GARDEN WALL IRRIGATED TURF LEAF TOWER BRASS BOLLARD LIGHT, VOLTLIGHTING.COM ACCESS TO COURTYARD, TYP. BBQ COUNTER STANDARD GRAY CONCRETE SAWCUT SCORE JOINTS, MEDIUM BROOM FINISH 01 HARDSCAPE SYMBOL DESCRIPTION CONCRETE 02 LANDSCAPE MATERIAL SYMBOL DESCRIPTION IRRIGATED TURF COBBLE MULCH RIVER COBBLE TREES COMMON NAME ATH HOT WINGS MAPLE COP PRAIRIE SENTINEL HACKBERRY GAT SKYLINE HONEY LOCUST GDE SEEDLESS KENTUCKY COFFEETREE JSS ROCKY MOUNTAIN JUNIPER MSP SPRING SNOW CRAB APPLE MRB RED BARRON CRAB APPLE PPA BAKERI SPRUCE PB BRISTLECONE PINE PES PINYON PINE PT QUAKING ASPEN QSS SHUMARD RED OAK SRE JAPANESE LILAC TREE UFR FRONTIER ELM SHRUBS COMMON NAME AO STANDING OVATION SERVICEBERRY ACP PANCHITO MANZANITA BTA CRIMSON PYGMY BARBERRY BT ORANGE ROCKET JAPANESE BARBERRY BM GREEN TOWER COMMON BOXWOOD CM MOUNTAIN MAHOGANY CAI IVORY HALO VARIEGATED DOGWOOD CSA ARCTIC FIRE RED TWIG DOGWOOD CSI ISANTI RED TWIG DOGWOOD CDI SPREADING COTONEASTER DBB BRIGGS MOONLIGHT DAPHNE DB CAROL MACKIE DAPHNE EC CHOLLIPO JAPANESE EUONYMUS HME ENDLESS SUMMER HYDRANGEA JSU BUFFALO JUNIPER JS MEDORA JUNIPER MA COMPACT OREGON GRAPE MRE CREEPING COLORADO HOLLY PMB BIG TUNA MUGO PINE RC CUNNINGHAM'S WHITE RHODODENDRON RTA SKUNKBUSH SUMAC RMS MORDEN SUNRISE SHRUB ROSE ORNAMENTAL GRASSES COMMON NAME BGB BLONDE AMBITION GRAMA GRASS CAK FEATHER REED GRASS IR JAPANESE BLOOD GRASS PERENNIALS COMMON NAME AMO MOONSHINE YARROW AAC CORONADO HYSSOP AC2 NODDING ONION AC ROCKY MOUNTAIN COLUMBINE AVS SEAFOAM SAGE EPU PURPLE CONEFLOWER GO SWEET WOODRUFF HP PALACE PURPLE CREVICE ALUMROOT HSS VARIEGATED CORAL BELLS MO LEMON BALM NWL WALKERS LOW CATMINT RFO BLACK-EYED SUSAN DRAWING NUMBER: ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No.DESCRIPTION DATE REVISIONS No.DESCRIPTION DATE Plotted By: Katy Thompson Layout: COURTYARDS Printed On: 4/19/2023 9:43 AM File Name: COURTYARDS.dwgORIGINAL SIZE 24X36 ENTI T L E M E N T DRA WI N G S NOT F O R CON S T R U C TI O N 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com RIPLEY DESIGN INC. Stephanie Hansen, PLA 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 ENGINEER ARCHITECT PLANNER / LANDSCAPE ARCHITECT NORTHERN ENGINEERING Stephanie Thomas 301 N. Howes St. #100 Fort Collins, CO 80521 p. 970.221.4158 VAUGHT FRYE LARSON ARCHITECTS Bo Evans 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.1191 ESL Fort Collins LLC Hunter MacLeod 1550 Market St, Suite 200 Denver, CO 80202 OWNER/APPLICANT COURTYARDS FDP SUBMITTAL STANFORD SENIOR LIVING 4/19/2023CITY COMMENTS1 04 DD 7/20/2021 7/14/2021FDP03 2/4/2021SD02 12/23/2020PDP01 FORT COLLINS, CO KR,KT NV,EC,SH R20-025 L6 OF 7 NORTH 0 5 10 20 SCALE: 1"=10'-0" FO G SD SS T UE W FIBER OPTIC UTILITY GAS UTILITY STORM DRAIN UTILITY SANITARY SEWER UTILITY TELEPHONE UTILITY UNDERGROUND ELECTRIC UTILITY WATER LINE UTILITY PROPERTY BOUNDARY VAULT ELEC T G ELEC EXISITING TREES TO REMAIN (SEE INVENTORY AND MITIGATION PLAN, SHEET L1) STREET LIGHT FIRE HYDRANT TRANSFORMER ELECTRIC BOX ELECTRIC VAULT TELEPHONE PEDESTAL EXISTING SIGN INLET GRATE GAS METER x EXISTING FENCE PROPOSED FENCE LEGEND MEMORY CARE GARDEN COURTYARD ROOF TOP GARDEN STREET LIGHT PLANT MATERIAL LEGEND STUCCO 2 CEMENTITIOUS SIDING SPLIT FACE CMU STUCCO 1 ALUMINUM STOREFRONT ALUMINUM STOREFRONT VINYL WINDOW STUCCO 2 STUCCO 1STEEL RAILING CEMENTITIOUS SIDING PREFINISHED METAL WALL CAP STUCCO REVEAL SITE WALL AND FENCE BEYOND STUCCO BANDING PREFINISHED METAL FASCIA MONROE AVE. 147' - 8 1/2" 149' - 6" MECHANICAL SCREEN BEYOND -EMBOSSED METAL PANEL ROOF ACCESS STAIR TOWER STEEL SUNSHADE MECHANICAL LOUVER BASEMENT LEVEL 90' - 0" FIRST FLOOR LEVEL 111' - 11 1/2" SECOND FLOOR LEVEL THIRD FLOOR LEVEL 134' - 6 1/2" FOURTH FLOOR LEVEL LAMBSTONGUE65' - 6"STEEL BALCONY AND RAILING 123' - 3" 100' - 0" 155' - 6" RECESSED SPLIT FACE CMU BANDING 1. ALL EXTERIOR WALL MOUNTED LIGHTS TO BE FULL CUT-OFF, TYP EXTERIOR ELEVATION GENERAL NOTES EXTERIOR FINISH SCHEDULE STUCCO 1 COLOR LIGHT GREY STUCCO 2 COLOR DARK GREY STONE COLOR TAN CEMENTITIOUS SIDING DARK BROWN TRIM DARK GREY & LIGHT GREY SPLIT FACE CMU DARK GREY STEEL SUNSHADES DARK GREY STOREFRONT FRAME BLACK BALCONY RAILING BLACK GARAGE ENTRY ALUMINUM STOREFRONT ALUMINUM STOREFRONT CEMENTITIOUS SIDING MANUFACTURED STONE VENEER STUCCO 2 STUCCO 1 WALL MOUNTED LIGHT FIXTURE SPLIT FACE CMU MECHANICAL LOUVER CEMENTITIOUS SIDING PREFINISHED METAL WALL CAP STEEL RAILING STEEL SUNSHADE STEEL SUNSHADE VINYL WINDOW MANUFACTURED STONE SILL MANUFACTURED STONE ACCENT TRIM, TYP SPLIT FACE CMU PORTE COCHERE STUCCO REVEAL MECHANICAL SCREEN - EMBOSSED METAL PANEL MECHANICAL SCREEN - EMBOSSED METAL PANEL ADDRESS NUMBERS 147' - 8 1/2" ROOF ACCESS STAIR TOWER MECHANICAL SCREEN BEYOND - EMBOSSED METAL PANEL STUCCO BANDINGMECHANICAL VENT VINYL WINDOW STUCCO 1 PREFINISHED METAL FASCIA PRECAST CONCRETE HEADER MANUFACTURED STONE ACCENT TRIM CEMENTITIOUS SIDING ALUMINUM STOREFRONT RECESSED SPLIT FACE CMU BANDINGRECESSED SPLIT FACE CMU BANDING 100' - 0" FIRST FLOOR LEVEL BRAKE METAL ACCENT PRECAST CONCRETE SILL FDC 10X2 STEEL TUBE, PAINTED LAMBSTONGUE 148' - 2" 149' - 6" 149' - 6" STUCCO REVEAL155' - 6" 158' - 7" PREFINISHED METAL WALL CAP STUCCO BANDING STEEL SUNSHADE CEMENTITIOUS SIDING STUCCO 1 STUCCO 2 149' - 6" LOW SITE WALL SITE FENCE STEEL RAILING 100' - 0" MECHANICAL VENT 147' - 8 1/2" 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S OWNER: UNITED PROPERTIES CONTRACTOR: BRINKMAN CONSTRUCTION MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ADONAI PROFESSIONAL SERVICES, INC.4/18/2023 5:48:51 PM4/18/2023 5:48:51 PMAutodesk Docs://Stanford Senior Living (Gallery at Fort Collins)/STANFORD_Main Building_ARCH_v2022.rvtA1 EXTERIOR ELEVATIONS STANFORD SENIOR LIVING FORT COLLINS, CO FDP PLANNING SUBMITTAL 2020-35 SCALE:1/16" = 1'-0"2 PLANNING ELEVATION -EAST SCALE:1/16" = 1'-0"1 PLANNING ELEVATION -SOUTH SCALE:1/16" = 1'-0"3 PLANNING ELEVATION -NORTHEAST SCALE:4 PERSPECTIVE VIEW -SOUTHEAST CORNER PLANNING SUBMITTAL 1 12-23-2020 PLANNING RESUBMITTAL 1 03-31-2021 PLANNING SUBMITTAL 2 04-28-2021 FDP PLANNING SUBMITTAL 07-14-2021 FDP PLANNING SUBMITTAL 09-08-2021 FDP PLANNING SUBMITTAL 3 12-02-2022 FDP PLANNING SUBMITTAL 6 03-15-2023 FDP PLANNING SUBMITTAL 7 04-19-2023 CEMENTITIOUS SIDING STUCCO 1 STUCCO 2 ALUMINUM STOREFRONT PREFINISHED METAL WALL CAP STEEL SUNSHADE STUCCO BANDING VINYL WINDOW 149' - 6" 100' - 0" EXTERIOR EXIT STAIR STEEL RAILING 147' - 8 1/2" 155' - 6" PTD BOLLARD 1. ALL EXTERIOR WALL MOUNTED LIGHTS TO BE FULL CUT-OFF, TYP EXTERIOR ELEVATION GENERAL NOTES EXTERIOR FINISH SCHEDULE STUCCO 1 COLOR LIGHT GREY STUCCO 2 COLOR DARK GREY STONE COLOR TAN CEMENTITIOUS SIDING DARK BROWN TRIM DARK GREY & LIGHT GREY SPLIT FACE CMU DARK GREY STEEL SUNSHADES DARK GREY STOREFRONT FRAME BLACK BALCONY RAILING BLACK STUCCO BANDING STUCCO 1 STUCCO 2 STEEL SUNSHADE STUCCO REVEAL STEEL RAILING CEMENTITIOUS SIDING ALUMINUM STOREFRONT ENTRY MECHANICAL VENT STUCCO 2 STUCCO BANDING STUCCO 1 147' - 8 1/2" 100' - 0" SPLIT FACE CMU STEEL SUNSHADE VINYL WINDOW CEMENTITIOUS SIDING ALUMINUM STOREFRONT PREFINISHED METAL WALL CAP ROOF ACCESS STAIR TOWER ROOF ACCESS STAIR TOWER VINYL WINDOW 147' - 8 1/2"148' - 6"149' - 6" EXTERIOR EXIT STAIR BEYOND LAMBSTONGUE 155' - 6"155' - 6" RECESSED SPLIT FACE CMU BANDING STUCCO 1 STUCCO 2 PREFINISHED METAL WALL CAP STEEL SUNSHADE CEMENTITIOUS SIDINGMECHANICAL VENTVINYL WINDOW STUCCO BANDING STUCCO REVEAL 100' - 0" 149' - 6"149' - 6"148' - 6" STEEL RAILING 147' - 8 1/2" SITE WALL AND FENCE BEYOND 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S OWNER: UNITED PROPERTIES CONTRACTOR: BRINKMAN CONSTRUCTION MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ADONAI PROFESSIONAL SERVICES, INC.4/18/2023 5:49:42 PM4/18/2023 5:49:42 PMAutodesk Docs://Stanford Senior Living (Gallery at Fort Collins)/STANFORD_Main Building_ARCH_v2022.rvtA2 EXTERIOR ELEVATIONS STANFORD SENIOR LIVING FORT COLLINS, CO FDP PLANNING SUBMITTAL 2020-35 SCALE:1/16" = 1'-0"2 PLANNING ELEVATION -WEST SCALE:1/16" = 1'-0"1 PLANNING ELEVATION -NORTH SCALE:1/16" = 1'-0"3 PLANNING ELEVATION -NORTHWEST SCALE:4 PERPSECTIVE VIEW -NORTHWEST CORNER PLANNING SUBMITTAL 1 12-23-2020 PLANNING RESUBMITTAL 1 03-31-2021 PLANNING SUBMITTAL 2 04-28-2021 FDP PLANNING SUBMITTAL 07-14-2021 FDP PLANNING SUBMITTAL 09-08-2021 FDP PLANNING SUBMITTAL 3 12-02-2022 FDP PLANNING SUBMITTAL 6 03-15-2023 FDP PLANNING SUBMITTAL 7 04-19-2023 A37 A3 3 A3 4 A3 8 20' - 0"STEEL DOORS, PAINT DARK GREY 8" SPLIT FACE CMU, DARK GREY CONCRETE PAD 28' - 0" SLOPE GENERATOR CONTINUOUS STEEL ANGLE, PAINT BLACK 6 YARD DUMPSTER, TYP. 95 GALLON RECEPTACLE, TYP. SPLIT FACE CMU, DARK GREY PREFINISHED METAL WALL CAP, BLACK 108' - 2 1/2" RECESSED SPLIT FACE CMU BANDING 108' - 2 1/2" SPLIT FACE CMU, DARK GREY PREFINISHED METAL WALL CAP, BLACK STEEL DOOR, PAINTED BLACK RECESSED SPLIT FACE CMU BANDING SPLIT FACE CMU 108' - 2 1/2" PREFINISHED METAL WALL CAP, BLACK RECESSED SPLIT FACE CMU BANDING SPLIT FACE CMU -DARK GREY STEEL DOORS, PAINT DARK GREY 108' - 2 1/2" RECESSED SPLIT FACE CMU BANDING 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S OWNER: UNITED PROPERTIES CONTRACTOR: BRINKMAN CONSTRUCTION MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ADONAI PROFESSIONAL SERVICES, INC.4/18/2023 5:50:47 PM4/18/2023 5:50:47 PMAutodesk Docs://Stanford Senior Living (Gallery at Fort Collins)/STANFORD_Main Building_ARCH_v2022.rvtA3 PERSPECTIVE VIEWS STANFORD SENIOR LIVING FORT COLLINS, CO FDP PLANNING SUBMITTAL 2020-35 SCALE:1 PERSPECTIVE VIEW -SOUTHWEST SCALE:2 PERSPECTIVE VIEW -NORTHEAST SCALE:5 PERSPECTIVE VIEW -PORTE COCHERE SCALE:1/8" = 1'-0"6 ENLARGED PLAN -TRASH ENCLOSURE FDP SCALE:1/8" = 1'-0"4 TRASH ENCLOSURE ELEVATION WEST SCALE:1/8" = 1'-0"3 TRASH ENCLOSURE ELEVATION SOUTH SCALE:1/8" = 1'-0"8 TRASH ENCLOSURE ELEVATION NORTH SCALE:1/8" = 1'-0"7 TRASH ENCLOSURE ELEVATION EAST PLANNING SUBMITTAL 1 12-23-2020 PLANNING RESUBMITTAL 1 03-31-2021 PLANNING SUBMITTAL 2 04-28-2021 FDP PLANNING SUBMITTAL 07-14-2021 FDP PLANNING SUBMITTAL 09-08-2021 FDP PLANNING SUBMITTAL 3 12-02-2022 FDP PLANNING SUBMITTAL 6 03-15-2023 FDP PLANNING SUBMITTAL 7 04-19-2023 DIGITAL MATERIAL BOARD LEGEND STUCCO TEXTURE CEMENTITIOUS LAP SIDING CEMENTITOUS SIDING COLOR DARK BROWNSTUCCO 2 COLOR (DARK GREY)STUCCO 1 COLOR (LIGHT GREY) STOREFRONT FRAME VINYL WINDOW FRAMESYNTHENTIC STONE FRAME COLOR (BLACK)FRAME COLOR (DARK TAN) STEEL SUNDHADES SPLIT FACE CMU CEMENTITIOUS SHIPLAP SIDING CEMENTITOUS SIDING COLOR DARK BROWN METAL SCREEN AT GARAGE OPENINGS (BLACK) FRAME COLOR (BLACK) 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S OWNER: UNITED PROPERTIES CONTRACTOR: BRINKMAN CONSTRUCTION MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ADONAI PROFESSIONAL SERVICES, INC.4/18/2023 5:51:39 PM4/18/2023 5:51:39 PMAutodesk Docs://Stanford Senior Living (Gallery at Fort Collins)/STANFORD_Main Building_ARCH_v2022.rvtA4 DIGITAL MATERIAL BOARD STANFORD SENIOR LIVING FORT COLLINS, CO FDP PLANNING SUBMITTAL 2020-35 MANUFACTURED STONE SPLIT FACE CMU SHIP LAP SIDING STUCCO COLOR 1 STUCCO COLOR 2 GAURDRAIL ROOF TOP PATIO STUCCO COLOR 2 CEMENTITIOUS SIDING MANUFACTURED STONE VINYL WINDOW STOREFRONT ASSEMBLY STUCCO COLOR 2PORTE COCHERE SHIP LAP SIDING SUNSHADE PLANNING SUBMITTAL 1 12-23-2020 PLANNING RESUBMITTAL 1 03-31-2021 PLANNING SUBMITTAL 2 04-28-2021 FDP PLANNING SUBMITTAL 07-14-2021 FDP PLANNING SUBMITTAL 09-08-2021 FDP PLANNING SUBMITTAL 3 12-02-2022 FDP PLANNING SUBMITTAL 6 03-15-2023 FDP PLANNING SUBMITTAL 7 04-19-2023 MANUFACTURED STONE VENEER PRECAST CONCRETE SILL RECESSED SPLIT FACE CMU ALUMINUM STOREFRONT MANUFACTURED STONE ACCENT TRIM MANUFACTURED STONE ACCENT TRIM STUCCO SPLIT FACE CMU PRE CAST HEADER METAL FRAME W/ MESH SCREENS VINYL WINDOW CEMENTITIOUS SIDING MANUFACTURED STONE VENEER PRECAST CONCRETE SILL RECESSED SPLIT FACE CMU ALUMINUM STOREFRONT MANUFACTURED STONE ACCENT TRIM MANUFACTURED STONE ACCENT TRIM STUCCO SPLIT FACE CMU STUCCO 2 VINYL WINDOW CEMENTITIOUS SIDING STUCCO 2 STUCCO 1 VINYL WINDOW STUCCO REVEAL MANUFACTURED STONE VENEER PRECAST CONCRETE SILL RECESSED SPLIT FACE CMU SPLIT FACE CMU PRECAST CONCRETE HEADER ALUMINUM STOREFRONT RECESSED SPLIT FACE CMU STUCCO BAND STUCCO VINYL WINDOW CEMENTITIOUS SIDING 5 A5 3 A5 6 A5 4 A5 4 A5 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S OWNER: UNITED PROPERTIES CONTRACTOR: BRINKMAN CONSTRUCTION MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ADONAI PROFESSIONAL SERVICES, INC.4/18/2023 5:52:58 PM4/18/2023 5:52:58 PMAutodesk Docs://Stanford Senior Living (Gallery at Fort Collins)/STANFORD_Main Building_ARCH_v2022.rvtA5 ELEVATION DETAILS STANFORD SENIOR LIVING FORT COLLINS, CO FDP PLANNING SUBMITTAL 2020-35 SCALE:1 AXON SOUTH SCALE:3 WINDOW DETAIL AT FIRST FLOOR LEVEL SCALE:4 WINDOW AXON AT RESIDENTIAL UNIT SCALE:5 WINDOW DETAIL AT RESIDENTIAL UNIT SCALE:6 WINDOW DETAIL AT GARAGE LEVEL SCALE:2 AXON NORTH PLANNING SUBMITTAL 1 12-23-2020 PLANNING RESUBMITTAL 1 03-31-2021 PLANNING SUBMITTAL 2 04-28-2021 FDP PLANNING SUBMITTAL 07-14-2021 FDP PLANNING SUBMITTAL 09-08-2021 FDP PLANNING SUBMITTAL 3 12-02-2022 FDP PLANNING SUBMITTAL 6 03-15-2023 FDP PLANNING SUBMITTAL 7 04-19-2023 MONROE DR STANFORD RD CYCLE APARTMENTS MARRIOTT HOTEL PARKING LOT MONROE DR STANFORD RD CYCLE APARTMENTS MARRIOTT HOTEL PARKING LOT MONROE DR STANFORD RD CYCLE APARTMENTS MARRIOTT HOTEL PARKING LOT MONROE DR STANFORD RD CYCLE APARTMENTS MARRIOTT HOTEL PARKING LOT MONROE DR STANFORD RD CYCLE APARTMENTS MARRIOTT HOTEL PARKING LOT MONROE DR STANFORD RD CYCLE APARTMENTS MARRIOTT HOTEL PARKING LOT L.U.C. CODE SECTION 3.2.3 -SOLAR ACCESS, ORIENTATION, SHADING Project Summary The proposed project is a four-story senior housing facility located at the southwest corner of Monroe Dr and Stanford Road. The existing vacant lot is located in the CG (General Commercial) Zone District and the Transit-Oriented Development Overlay Zone. A shadow study is provided as required for any building over 40 feet tall. The fourth floor roof line is at 56 feet above the ground plane along Monroe Drive and 66 feet above the southern parking lot. The site’s topography slopes to create a walk-out basement condition on the south side of the property. The shadow study is summarized in the following paragraphs. Per LUC code section 3.2.3 (E), the 25 foot wall comparison is not required because the property is located in the Transit Overlay District. Study Overview A shadow study was performed on the proposed four-story senior housing facility. The shadows were generated using a computer modeling program called Revit Architecture. Per code section 3.2.3(A), a study must be done on December 21 to demonstrate the longest shadow day of the year (winter solstice). We included June 21st is our study as well to show the shortest day of the year (Summer Solstice). This allowed the shadow study to look at the longest and shortest shadow days of the year. We also looked at three times for each day; 9am, noon, and 3pm. This allowed the study to look at the change of the shadows throughout the day. Conclusion June 21 June 21 is the longest day of the year and the sun is the highest in the sky. This creates the shortest shadows. Our graphics show that the shadows barely reach off of the property all day long. The shadows do not affect the Cycle Apartments or adjacent Marriot Hotel. December 21 On December 21, the longest shadow day of the year, the shadows of the building reach across Monroe Drive to the Cycle Apartments property at 9am, noon, and 3pm, however the shadows do not reach the buildings. Even though, the shadows are the longest on this day, the number of affected buildings has not increased. This is a result of the site's location and relation to Monroe Drive and Stanford Road. In final summary, the shadow study shows that the proposed building allows sunlight to the adjacent buildings throughout all times of the year. The shadows do reach the Cycle Apartment, Marriot Hotel or Aspen Leaf Apartments on the longest shadow day of the year. SHADOW STUDY SUMMARY 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. COPYRIGHT: SHEET ISSUANCES DESCRIPTION DATE A R C H I T E C T U R E + I N T E R I O R S OWNER: UNITED PROPERTIES CONTRACTOR: BRINKMAN CONSTRUCTION MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL ELECTRICAL ENGINEER: ADONAI PROFESSIONAL SERVICES, INC.4/18/2023 5:54:13 PM4/18/2023 5:54:13 PMAutodesk Docs://Stanford Senior Living (Gallery at Fort Collins)/STANFORD_Main Building_ARCH_v2022.rvtA6 SHADOW STUDY STANFORD SENIOR LIVING FORT COLLINS, CO FDP PLANNING SUBMITTAL 2020-35SUMMER SOLSTICE JUNE 21 WINTER SOLSTICE DECEMBER 21 SCALE: 6 SHADOW STUDY -SUMMER 9AM SCALE: 5 SHADOW STUDY -SUMMER NOON SCALE: 4 SHADOW STUDY -SUMMER 3PM SCALE: 3 SHADOW STUDY -WINTER 9AM SCALE: 2 SHADOW STUDY -WINTER NOON SCALE: 1 SHADOW STUDY -WINTER 3PM PROJECT NORTH PLANNING SUBMITTAL 1 12-23-2020 PLANNING RESUBMITTAL 1 03-31-2021 PLANNING SUBMITTAL 2 04-28-2021 FDP PLANNING SUBMITTAL 07-14-2021 FDP PLANNING SUBMITTAL 09-08-2021 FDP PLANNING SUBMITTAL 3 12-02-2022 FDP PLANNING SUBMITTAL 6 03-15-2023 FDP PLANNING SUBMITTAL 7 04-19-2023 WV H YDW WVWVD CC CC CC CC CC CC CC CC D1 D1 D1 D1 D1 D1 D1 D1 D1 HH HH D1 D1 D1 D1 D1 D D SS HH D D HH HH HH HH HH HH HH HH HH HH HH HH HH HH HH GG GG GG CC CCCC CC CC CC SS2 x 4 P1.0 PHOTOMETRIC SITE PLAN DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: COPYRIGHT: 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON NOT FO R C O N S T R U C T I O N FOR R E F E R E N C E O N L Y A R C H I T E C T U R E + I N T E R I O R S VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. SHEET ISSUANCES DESCRIPTION DATE CIVIL ENGINEER: NORTHERN ENGINEERING SERVICES LANDSCAPE ARCHITECT: RIPLEY DESIGN INC. STRUCTURAL ENGINEER: RAKER RHODES ENGINEERING, LLC MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL SERVICES LLC ELECTRICAL ENGINEER: APS, INC INTERIOR DESIGN: BANKO DESIGN FOOD SERVICE & LAUNDRY: 3PM DESIGN CONSULTANTS STANFORD SENIOR LIVING FORT COLLINS, CO FDP Submittal APS 221-20 FDP Submittal 09/08/2021 FDP Submittal 12/02/2022 FDP Submittal 04/19/2023 P1.1 PHOTOMETRIC SITE PLAN CUT-SHEETS DRAWING NUMBER: PROJECT NUMBER: SEAL: IN ASSOCIATION WITH: COPYRIGHT: 419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191 108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710 www.VFLA.com Strength in design. Strength in partnership. Strength in community. VAUGHT FRYE LARSON ARONSON NOT FO R C O N S T R U C T I O N FOR R E F E R E N C E O N L Y A R C H I T E C T U R E + I N T E R I O R S VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC. THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED OR COPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA. SHEET ISSUANCES DESCRIPTION DATE CIVIL ENGINEER: NORTHERN ENGINEERING SERVICES LANDSCAPE ARCHITECT: RIPLEY DESIGN INC. STRUCTURAL ENGINEER: RAKER RHODES ENGINEERING, LLC MECHANICAL & PLUMBING ENGINEER: INTEGRATED MECHANICAL SERVICES LLC ELECTRICAL ENGINEER: APS, INC INTERIOR DESIGN: BANKO DESIGN FOOD SERVICE & LAUNDRY: 3PM DESIGN CONSULTANTS STANFORD SENIOR LIVING FORT COLLINS, CO FDP Submittal APS 221-20 FDP Submittal 09/08/2021 FDP Submittal 12/02/2022 FDP Submittal 04/19/2023 6 7 TYPE HH 3 5 TYPE SS TYPE CC TYPE SS2 4 TYPE GG12TYPE D1TYPE D