HomeMy WebLinkAboutIMPALA REDEVELOPMENT - FDP230001 - CORRESPONDENCE - STAFF'S PROJECT COMMENTS  Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6689 970.224.6134 ‑ fax fcgov.com/developmentreview April 05, 2023 Nichole Rex HOUSING CATALYST 1715 W MOUNTAIN AVE Fort Collins, CO 805212359 RE: Impala Redevelopment, FDP230001, Round Number 3 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of Impala Redevelopment. If you have questions about any comments, you may contact the individual commenter or direct your questions through your Development Review Coordinator, Brandy Bethurem Harras via phone at 970‑416‑2744 or via email at bbethuremharras@fcgov.com. Comment Summary: Department: Development Review Coordinator Contact: Brandy Bethurem Harras, 970‑416‑2744, bbethuremharras@fcgov.com Topic: General Comment Number: 1 01/31/2023: INFORMATION: I will be your primary point of contact throughout the development review and permitting process. If you have any questions, need additional meetings with the project reviewers, or need assistance throughout the process, please let me know and I can assist you and your team. Please include me in all email correspondence with other reviewers and keep me informed of any phone conversations. Thank you! Comment Number: 2 01/31/2023: SUBMITTAL: As part of your resubmittal, you will respond to the comments provided in this letter. This letter is provided to you in Microsoft Word format. Please use this document to insert responses to each comment for your submittal, using a different font color. When replying to the comment letter please be detailed in your responses, as all comments should be thoroughly addressed. Comments requiring action should NOT have a response such as noted or acknowledged. You will need to provide references to specific project plans, pages, reports, or explanations of why comments have not been addressed [when applicable]. Comment Number: 3 01/31/2023: SUBMITTAL: Please follow the Electronic Submittal Requirements and File Naming Standards found at https://www.fcgov.com/developmentreview/files/electronic submittal requirements and file naming standards_v1_8 1 19.pdf?1566857888. File names should begin with the file type, followed by the project information, and round number. Example: UTILITY PLANS_PROJECT NAME_PDP_Rd2.pdf File type acronyms maybe appropriate to avoid extremely long file names. Example: TIS for Traffic Impact Study, ECS for Ecological Characterization Study. Reach out to me if you would like a list of suggested names. *Please disregard any references to paper copies, flash drives, or CDs. Comment Number: 4 01/31/2023: SUBMITTAL: All plans should be saved as optimized/flattened PDFs to reduce file size and remove layers. Per the Electronic Submittal Requirements AutoCAD SHX attributes need to be removed from the PDF’s. AutoCAD turns drawing text into comments that appear in the PDF plan set, and these must be removed prior to submittal as they can cause issues with the PDF file. The default setting is "1" ("on") in AutoCAD. To change the setting and remove this feature, type "EPDFSHX" (version 2016.1) or “PDFSHX (version 2017 and newer) in the command line and enter "0". Read this article at Autodesk.com for more on this topic: https://knowledge.autodesk.com/support/autocad/troubleshooting/caas/sfdcarti cles/sfdcarticles/Drawing‑text‑appears‑as‑Comments‑in‑a‑PDF‑created‑by‑Aut oCAD.html Comment Number: 5 01/31/2023: SUBMITTAL: Resubmittals are accepted any day of the week, with Wednesday at noon being the cut‑off for routing the same week. When you are preparing to resubmit your plans, please notify me with an expected submittal date with as much advanced notice as possible. Comment Number: 6 01/31/2023: INFORMATION: Please resubmit within 180 days, approximately 6 months, to avoid the expiration of your project. Comment Number: 8 01/31/2023: FOR FINAL APPROVAL: All "For Final Approval / For Approval" comments need to be addressed and resolved prior to moving forward with the final documents and recording of this project. I will provide a recording checklist and process information when we are closer to this step. Comment Number: 9 01/31/2023: INFORMATION: LUC 2.211 Lapse, Term of Vested Right: Within a maximum of three (3) years following the approval of a final plan or other site‑specific development plan, the applicant must undertake, install and complete all engineering improvements (water, sewer, streets, curb, gutter, streetlights, fire hydrants and storm drainage) in accordance with city codes, rules and regulations. The period of time shall constitute the "term of the vested property right." Failure to undertake and complete such engineering improvements within the term of the vested property right shall cause a forfeiture of the vested property right and shall require resubmission of all materials and reapproval of the same to be processed as required by this Code. All dedications as contained on the final plat shall remain valid unless vacated in accordance with law. Department: Engineering Development Review Contact: Tim Dinger, , tdinger@fcgov.com Topic: General Comment Number: 1 02/27/2023: FOR DEVELOPMENT AGREEMENT ‑ UPDATED: We need the lender information to complete the first draft of the development agreement. Please provide that as soon as possible, and email to your DRC. 01/19/2023: FOR DEVELOPMENT AGREEMENT: The Development Agreement information form has "Julie J. Brewen" listed as the both the individual that is signing the DA for the developers, as well as in the attest field. The person who is attesting to Julie's signature must be a different person than Julie, who is signing the DA for the developer. Please revise the DA info form to have a different person in the attest field. In the meantime, we will begin drafting the development agreement. We intend on providing the first draft of the DA around the same time as we provide FDP round 2 comments Comment Number: 3 03/06/2023: FOR ROW VACATION ‑ UPDATED: The ROW vacation forms are under review. We will update you as we start the vacation process through City Council. 01/25/2023: FOR ROW VACATION: The ROW Vacation forms should be accompanied by a letter of request. The letter of request should include a short (1 paragraph) description about what you are proposing to vacate, and justification as to why the vacation is necessary. It should also include your contact information. Please visit https://www.fcgov.com/engineering/files/row‑vacation‑process_2022.pdf?1646 783322 for more information on the ROW vacation process. Department: Stormwater Engineering Contact: Stephen Agenbroad, , sagenbroad@fcgov.com Topic: General Comment Number: 5 03/31/2023: FOR FINAL APPROVAL ‑ UPDATED: Please show the irrigation lateral on the storm water profile for Storm Drain 1. 03/10/2023: FOR FINAL APPROVAL: The irrigation lateral is being located on March 15th. Further information will be included in the final draft letter. 01/31/2023: FOR FINAL APPROVAL: The irrigation lateral on the southern portion needs further discussion. Comment Number: 13 03/31/2023: FOR FINAL APPROVAL: In the forebay detail, please show that the forebay has been moved out of the rain garden media or that a stable soil (#57 rock or native soil) is located under the forebay to prevent any possible settling from occurring. In addition, please lower the relief notch so that it is flush with the curb of the forebay, and make sure the curb is flush with the rain garden media. Department: Water‑Wastewater Engineering Contact: Stephen Agenbroad, , sagenbroad@fcgov.com Topic: General Comment Number: 1 03/31/2023: FOR FINAL APPROVAL ‑ UPDATED: Please submit the AWWA Manual M22 calcs as PDFs for filing purposes. 03/10/2023: FOR FINAL APPROVAL‑UNRESOLVED: 01/31/2023: FOR FINAL APPROVAL: Please also include AWWA M22 meter sizing calculations for additional reference. The IPC calculations can also be included but the city requires AWWA M22 calculations be used when determining meter sizing. Comment Number: 6 03/31/2023: FOR FINAL APPROVAL: Based on the AWWA water meter spreadsheets, it appears that Building A requires at least a 1.5‑inch meter. The utility plans show building A only having a 1‑inch meter. Please update the utility plans to match the meter sizing. In addition, please submit the water meter sizing tables as PDFs for the next submittal. Comment Number: 7 04/03/2023: INFORMATION ONLY The city would suggest that the fire line does not run under the stairs that lead up to the concrete patio. This is to ensure clear access in the case that the fire line ever needed maintenance in the future. Department: Light And Power Contact: Austin Kreager, 970‑224‑6152, akreager@fcgov.com Topic: General Comment Number: 1 04/05/2023: FOR DCP: Thank you for submitting the revised C‑1 Forms. On Building D, the maximum conductor size allowed for connection into our single‑phase transformer is 350 kcmil. Please revise the C‑1 Form and One‑Line Diagram accordingly. 03/14/2023: FOR APPROVAL: Thank you for submitting the C‑1 forms. I can't seem to find the one‑line diagrams in your submittal though. Can you please send those directly to me? Thank you 02/01/2023: FOR APPROVAL: Multi family buildings and duplexes are treated as customer owned services; therefore a C‑1 form and one line diagram must be filled out and submitted to Light & Power Engineering for each NEW building. All secondary electric service work is the responsibility of the developer and their electrical consultant or contractor. A C‑1 form can be found here: https://www.fcgov.com/utilities/business/builders‑and‑developers/development‑f orms‑guidelines‑regulations Comment Number: 2 02/01/2023: INFORMATION: Light & Power will need AutoCAD files of the site plan, utility plans, and landscape drawings once plans are approved. Comment Number: 3 02/01/2023: INFORMATION: Electric capacity fees, development fees, building site charges and any system modification charges necessary to feed the site will apply to this development. Please contact me to discuss development fees or visit the following website for an estimate of charges and fees related to this project: http://www.fcgov.com/utilities/business/builders‑and‑developers/plant‑investmen t‑development‑fees Comment Number: 5 04/05/2023: FOR DCP: Thank you for submitting the revised C‑1 Forms. On Building D, the maximum conductor size allowed for connection into our single‑phase transformer is 350 kcmil. Please revise the C‑1 Form and One‑Line Diagram accordingly. 03/14/2023: FOR APPROVAL: The submitted C‑1 form shows three phase power being required for Building D. Three phase power will not be available for that building coming from the power source that was discussed During PDP. please coordinate with me offline so that I can better understand why your power needs are higher than I had anticipated. Department: Park Planning Contact: Missy Nelson, , mnelson@fcgov.com Topic: General Comment Number: 1 01/18/2023: INFORMATION: Both Park Planning & Development and Parks department comments will be provided by Missy Nelson | mnelson@fcgov.com Comment Number: 3 04/04/2023: FOR FINAL APPROVAL: Thanks for the update, when information is available, please show pipeline location on final plan sets. 03/14/2023: FOR HEARING ‑ UPDATED: There have been delays in locating the pipe. New Crew Chief are scheduled to deploy camera truck to locate 8am on 3/15/23. Once located, please show on landscape and utility plans. 02/03/2023: Pipe location will need to be established prior to approval of proposed storm line easement. Parks has it scheduled for Tuesday 2/7 and I will contact applicant with the information as soon as I get it. Department: Technical Services Contact: Jeff County, 970‑221‑6588, jcounty@fcgov.com Topic: Building Elevations Comment Number: 3 04/04/2023: FOR FINAL APPROVAL‑UNRESOLVED: Please change the title to match the other plan sets. Topic: Construction Drawings Comment Number: 8 04/04/2023: FOR FINAL APPROVAL‑UNRESOLVED: All Benchmark Statements must match on all sheets. Topic: Plat Comment Number: 1 04/04/2023: FOR FINAL APPROVAL‑UPDATED: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. If you have any specific questions about the redlines, please contact John Von Nieda at 970‑221‑6565 or HYPERLINK "mailto:jvonnieda@fcgov.com" jvonnieda@fcgov.com Department: Forestry Contact: Carrie Tomlinson, , ctomlinson@fcgov.com Topic: General Comment Number: 4 04/03/2023: FOR RECORDING: Please exchange the horse chestnut for another species from the recommended list emailed to you. No resubmittal or quick check is necessary for this Department: Historic Preservation Contact: Jim Bertolini, 970‑416‑4250, jbertolini@fcgov.com Topic: General Comment Number: 1 02/06/2023: FOR BUILDING PERMIT: Plan appears consistent with recommendations from PDP. As noted during PDP, a Plan of Protection must be submitted along with the Building Permit application for the six‑plex on Mulberry, documenting plan for protecting the Landmark (Ricketts Farmhouse) at 2300 W Mulberry St. during construction, including equipment plan, materials storage, and contact info for on‑site team. Department: Environmental Planning Contact: Scott Benton, (970)416‑4290, sbenton@fcgov.com Topic: General Comment Number: 5 04/04/2023: INFORMATION: This project requires a substantial amount of tree removal, thus the songbird nesting survey to satisfy Migratory Bird Treaty Act and City LUC requirements will be a substantial effort if tree removal occurs during the nesting season (Feb 1 ‑ July 31). Depending on project timing, this survey could be tied to DCP.