Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
IMPALA REDEVELOPMENT - FDP230001 - SUBMITTAL DOCUMENTS - ROUND 3 - SUPPORTING DOCUMENTATION (7)
Project Number Building address or number Residential or Non-Residential Pressure Zone at Project Fixture Value Number of Subtotal Fixture or Appliance (at 60 psi) Fixtures Fixture Value Toilet (tank) 4 20 80 Toilet (flush valve) 35 0 Urinal (wall or stall) 16 0 Urinal (flush valve) 35 0 Bidet 2 0 Shower (single head) 2.5 20 50 Sink (lavatory) 1.5 28 42 Kitchen Sink 2.2 16 35.2 Utility Sink 4 0 Dishwasher 2 16 32 Bathtub 8 18 144 Clothes Washer 6 16 96 Hose connections (with 50 ft of hose) 1/2 in. 5 6 30 5/8 in. 9 0 3/4 in. 12 0 Miscellaneous Bedpan washers 10 0 Drinking fountains 2 0 Dental units 2 0 Combined Fixture Value 509.2 Demand (gpm) 46 Pressure Adjustment Factor 0.9 Total Adjusted demand (gpm) 41.4 Preliminary Demand Size 1 1/2" Velocity (fps) 7.5 Required Meter Size 1-1/2" Review by: Approved by: Water Demand Estimate and Meter Sizing Using Fixture Values (Based on AWWA M22 Manual, Second Edition) Impala Redevelopment Building B