Loading...
HomeMy WebLinkAboutIMPALA REDEVELOPMENT - FDP230001 - DOCUMENT MARKUPS - ROUND 3 - UTILITY PLANSWEST MULBERRY STREET SOUTH TAFT HILL ROADC 100COVER SHEET 1 Original Field Survery: Northern Engineering Project No. 370-005 Date: December 28, 2021 Additional Field Survey: Northern Engineering Project No. 370-005 Date: March 17, 2022 FEBRUARY 2023 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH Project Datum: NAVD88 Benchmark 25-97 At the Southwest corner of Mulberry St. and Taft Hill Rd., on a concrete traffic signal base. Elevation = 5071.25 Benchmark 24-97 On a concrete headwall pipe in Rogers Park. South of the parking area of Rogers Park (150 feet South of large barn) 2500 block of Mulberry St. Elevation = 5102.71 Please Note: this plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (prior City of Fort Collins datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins datum) = NAVD88 - 3.17' Basis of Bearings The South line of the Southeast Quarter of Section 9, Township 7 North, Range 69 West of the 6th P.M. bearing North 88°51'30", as shown on ALTA. PROJECT BENCHMARKS: IMPALA REDEVELOPMENT PROJECT TEAM: Housing Catalyst Nichole Rex, Senior Project Manager 1715 W. Mountain Avenue Fort Collins, CO 80521 (970) 416-2910 Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER GEOTECHNICAL ENGINEER CTL | Thompson, Inc. Trace Krausse, EI 400 N Link Ln Fort Collins, CO 80524 (970) 206-9455 SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 9, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO (306 & 400 IMPALA CIRCLE) FIELD SURVEY BY: Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE SURVEYOR 1 C 100 COVER SHEET 2 C 101 GENERAL & CONSTRUCTION NOTES 3-5 C 102 - C 104 EXISTING CONDITIONS & DEMOLITION PLAN 6-8 C 200 - C 202 CIVIL SITE PLAN UTILITY SHEETS 9 C 300 OVERALL UTILITY PLAN 10-12 C 301 - C 303 UTILITY PLAN STORM DRAIN PROFILE SHEETS 13 C 310 STORM DRAIN 1 PLAN & PROFILE 14 C 311 STORM DRAIN 2 PLAN & PROFILE 15 C 312 STORM DRAINS 2-2 & 2-4 PLAN & PROFILE GRADING SHEETS 16 C 400 OVERALL GRADING PLAN 17-19 C 401 - C 403 GRADING PLAN DETAIL SHEETS 20 C 500 WATER DETAILS 21 C 501 SANITARY DETAILS 22-24 C 502-C 504 DRAINAGE DETAILS 25-26 C 505-C 506 SITE DETAILS DRAINAGE SHEETS 27 C 600 PRE-CONSTRUCTION EROSION CONTROL PLAN 28 C 601 DURING CONSTRUCTION EROSION CONTROL PLAN 29 C 602 POST-CONSTRUCTION EROSION CONTROL PLAN 30 C 603 EROSION CONTROL DETAILS 31 C 610 HISTORIC DRAINAGE EXHIBIT 32 C 611 DEVELOPED DRAINAGE EXHIBIT UTILITY PLANS CTL | Thompson Preliminary Geotechnical Investigation 306 and 400 Impala Circle Fort Collins, Colorado CTL|Thompson Project No. FC10389-115 Date: June 3, 2022 SUBSURFACE EXPLORATION BY: E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 LAPORTE AVENUE PROJECT LOCATION Ripley Design, Inc. Russ Lee, President 419 Canyon Avenue, Suite 200 Fort Collins, CO. 80521 (970) 224-5828 APPROVED: CITY ENGINEER:APPROVED SHEETS DATE WATER & WASTEWATER UTILITY:APPROVED SHEETS DATE STORMWATER UTILITY:APPROVED SHEETS DATE PARK PLANNING AND DEVELOPMENT:APPROVED SHEETS DATE TRAFFIC OPERATIONS:APPROVED SHEETS DATE ENVIRONMENTAL PLANNER:APPROVED SHEETS DATE City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R A. GENERAL NOTES 1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19.All recommendations of the Final Drainage Report, dated February 22, 2023 by Northern Engineering shall be followed and implemented. 20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 Benchmark 25-97 At the Southwest corner of Mulberry St. and Taft Hill Rd., on a concrete traffic signal base. Elevation = 5071.25 Benchmark 24-97 On a concrete headwall pipe in Rogers Park. South of the parking area of Rogers Park (150 feet South of large barn) 2500 block of Mulberry St. Elevation = 5102.71 Please Note: this plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (prior City of Fort Collins datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins datum) = NAVD88 - 3.17' Basis of Bearings The South line of the Southeast Quarter of Section 9, Township 7 North, Range 69 West of the 6th P.M. bearing North 88°51'30", as shown on ALTA. 41.All stationing is based on centerline of roadways unless otherwise noted. 42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48.Approved Variances are listed as follows (to be updated upon approval): CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16.For additional information see separate Stormwater Management Plan / Erosion Control Report for Impala Redevelopment. B. Street Improvement Notes 1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5.All lane lines for concrete pavement should be epoxy paint. 6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10.All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12.The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13.Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2.All recommendations of the Final Drainage Report, dated February 22, 2023 by Northern Engineering shall be followed and implemented. 3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1.All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3.Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4.HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City Water Detail 11A. F. Floodplain Notes 1.Portions of this property are located in the City regulated 100-year Canal Importation Floodplain/Floodway. Any development within the floodplain must comply with the safety regulations of Chapter 10 of City Municipal Code. The Contractor shall obtain a Floodplain Use Permit from the City of Fort Collins and pay all applicable floodplain use permit fees prior to commencing any construction activity (building of structures, grading, fill, detention ponds, bike paths, parking lots, utilities, landscaped areas, flood control channels, etc.) within the City of Fort Collins floodplain limits as delineated on the Final Subdivision Plat 2.“Any construction activities, nonstructural development (bridges, sidewalks, culverts, vegetation, curbcuts, grading, etc.) in the regulatory floodway must be preceded by a NoRise Certification, which must be prepared by a professional engineer licensed in the State of Colorado. 3.No storage of materials or equipment shall be allowed in the floodway, whether temporary (during construction) or permanent. 4.Any pedestrian bridges in the floodway that are not able to pass the 100 year flow are required to be “breakaway” and tethered. INFILL AND REDEVELOPMENT NOTE A.Despite everyone's best efforts, it is impossible to fully display subsurface information prior to excavation. This is especially true in areas of infill and redevelopment. Unknown subsurface conditions can have cost and schedule implications. Prior to finalizing contract terms, it is strongly recommended that the Owner and General Contractor have a candid discussion to formulate a strategy for dealing with such circumstances when they arise. The process and procures should be in place prior to excavation. Allowances and contingencies can address the cost implications, but additional measures are required to deal with scheduling and factors impacting sequence of work. The Architect, Engineer(s), and Construction Surveyor should be made aware of the protocol for dealing with such unknown subsurface conditions prior to starting work. C 101CONSTRUCTION NOTES GENERAL & 2 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EEEE E E EEEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCT V CTV CTVCTVCTVCTVCTVCTV CTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCT V CTV CTV CTVCTVCTV EEEEEEEE E E E 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WW W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W EEE E EEEEEEEEEEEEEEE E EEEEEEEEEG G G G G G G G G G G G G GGG G GGGG G GG G G GGGGGGGGGGGGGGGGGGGGGGGGGGGGGCTV CTV CTV CTV CTV CTV CTV CT V CT V E E E E E E E EEEEEEECTVCTVCTVCTVCTVEEE6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" WCTV CTV CTV CTV CTVCTV CTV CTV CTVCTVEE E E EE E E E EE E E E E E E E E E VAULT ELEC ELEC VAULT ELEC C T C CT S S HYDHY DVAULT ELEC VAULT ELEC CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC C VAULT ELEC X X XXXXX X X X XXXXXXXX X XXXXXXXXXX XXXX XX X XXXXX X X XXXXX X X X X X X X G G G G G G G G G G G E E E E E E E E E E G G ST GGGGG G G G G G G G G XXXXXXXXXXXXE E8" SS8" SS8" SS8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS WW WW WWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW WWWWWWWWWWWWWWWWWWWW WW WWWWWWWWWW WWWWWWWWWW WWWWXXW S S FO 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W X X X X X X XGGGGGGGGGFOFO FOFOFOFOFOFOFOFOFOFOTTTTTTTTTTTTT T G G IMPALA CIRCLE SOUTH IMPALA DRIVEEXISTING 8' CONCRETE PAN TO BE REMOVED EXISTING 31" DRIVE-OVER CURB & GUTTER W/ ATTACHED SIDEWALK TO BE REMOVED (TYP.) EXISTING 31" DRIVE-OVER CURB & GUTTER TO BE REMOVED (TYP.) EXISTING 10' CONCRETE PAN TO BE REMOVED EXISTING SANITARY SEWER MANHOLE TO BE REMOVED EXISTING BUILDING TO BE REMOVED (TYP.) EXISTING 31" DRIVE-OVER CURB & GUTTER W/ ATTACHED SIDEWALK TO BE REMOVED (TYP.) EXISTING 3 4" WATER SERVICE TO BE ABANDONED AT MAIN (TYP.) EXISTING ELECTRIC METER TO BE REMOVED (TYP.) EXISTING GAS METER TO BE REMOVED (TYP.) EXISTING SANITARY SEWER MANHOLE TO BE REMOVED EXISTING TRANSFORMER TO BE REMOVED EXISTING FENCE TO BE REMOVED (TYP.) EXISTING GROUNDED ELECTRIC AND CABLE TO BE REMOVED EXISTING PEDESTRIAN RAMP TO BE REMOVED EXISTING LIGHT POLE TO BE REMOVED (TYP.) EXISTING FIRE HYDRANT TO BE REMOVED EXISTING TREE TO BE REMOVED (TYP.) EXISTING CONCRETE PATIO TO BE REMOVED (TYP.) EXISTING CONCRETE DRIVEWAY TO BE REMOVED (TYP.) ±20 LF EXISTING 10" RCP STORM DRAIN TO BE REMOVED EXISTING DRAINAGE HEADWALL TO BE REMOVED EXISTING CONCRETE FOREBAY WITH PAN TO BE REMOVED EXISTING PLAYGROUND AREA TO BE REMOVED EXISTING PLAYGROUND AREA TO BE REMOVED ±52 LF DRIVEWAY APPROACH TO BE REMOVED EXISTING PEDESTRIAN RAMP TO BE REMOVED EXISTING 8' CONCRETE PAN TO BE REMOVED EXISTING 31" DRIVE-OVER CURB & GUTTER W/ ATTACHED SIDEWALK TO BE REMOVED (TYP.) EXISTING SANITARY SEWER MANHOLES TO REMAIN EXISTING 8" SANITARY SEWER EXISTING 16" WATER MAIN EXISTING 6" WATER MAIN TO REMAIN EXISTING BUILDING TO BE REMOVED (TYP.) PROPOSED SAWCUT (TYP.) ±19 LF DRIVEWAY APPROACH TO BE REMOVED ±20 LF DRIVEWAY APPROACH TO BE REMOVED PROPOSED SAWCUT (TYP.) EXISTING BUILDINGS TO REMAIN (TYP.) EXISTING 31" DRIVE-OVER CURB & GUTTER TO BE REMOVED (TYP.) EXISTING 49' ROW TO BE VACATED BY PLAT EXISTING 49' ROW TO BE VACATED BY PLAT EXISTING 8" SANITARY SEWER TO BE REMOVED EXISTING 8" SANITARY SEWER TO BE REMOVED EXISTING 3 4" WATER SERVICE TO BE ABANDONED AT MAIN (TYP.) EXISTING 3 4" WATER SERVICE TO BE ABANDONED AT MAIN (TYP.) EXISTING 49' ROW TO BE VACATED BY PLAT EXISTING 3 4" WATER SERVICE TO BE ABANDONED AT MAIN (TYP.) PROPOSED SAWCUT (TYP.) EXISTING FIRE HYDRANT TO REMAIN EXISTING 20' SANITARY SEWER EASEMENT TO BE VACATED BY PLAT EXISTING 1' OUTLOT TO BE VACATED BY PLAT EXISTING 1' OUTLOT TO BE VACATED BY PLAT EXISTING 1' OUTLOT TO BE VACATED BY PLAT EXISTING 3 4" WATER SERVICE TO BE ABANDONED AT MAIN (TYP.) EXISTING 2' CONCRETE PAN TO BE REMOVED EXISTING 8' SIDEWALK & RAMP TO BE REMOVED EXISTING FIRE HYDRANT TO BE REMOVED EXISTING 6' SIDEWALK EXISTING 6' SIDEWALK EXISTING 8" SANITARY SEWER EXISTING 6" WATER MAIN OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT EXISTING 10' MTN. STATES TELEPHONE & TELEGRAPH CO. EASEMENT (BOOK 1676, PAGE 134) TO BE VACATED BY PLAT EXISTING 6' UTILITY EASEMENT TO BE VACATED BY PLAT OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. ±24' FL-FL (TYP.) IMPALA CIRCLE ±38 LF FENCE TO BE REMOVED EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) EXISTING STRIPING TO REMAIN EXISTING SPEED HUMP W/ STRIPING TO REMAIN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 C 102DEMOLITION PLAN EXISTING CONDITIONS & 3 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.ALL PUBLIC SIDEWALKS, DRIVEWAYS, AND RAMPS, EXISTING OR PROPOSED, ADJACENT OR WITHIN THE SITE, SHALL MEET ADA STANDARDS OR BE RECONSTRUCTED TO CONFORM TO CURRENT ADA STANDARDS AS A PART OF THIS PROJECT. 7.CONTRACTOR SHALL COORDINATE WITH TRAFFIC CONTROL STAFF TO ENSURE UTILITY INSTALLATIONS WITHIN IMPALA DRIVE DO NOT IMPEDE SCHOOL AND NEIGHBORHOOD ACCESS. 8.SEE LANDSCAPING PLANS SHEETS L600 - L601 FOR DETAILED TREE MITIGATION INVENTORY AND DBH DIMENSIONS. EXISTING OVERHEAD UTILITY OHE ORIGINAL FIELD SURVEY: NORTHERN ENGINEERING PROJECT NO. 370-005 DATE: DECEMBER 28, 2021 ADDITIONAL FIELD SURVEY: NORTHERN ENGINEERING PROJECT NO. 370-005 DATE: MARCH 17, 2022 ASPHALT REMOVAL ASPHALT PATCH CONCRETE REMOVAL KEYMAP C 102 C 103 C 104 MATCH LINE - SEE SHEET C 103 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: 6" W 6" W 6" W6" W6" W6" W6" W6" WEEG G GGG G GGGG G GG G G G G G G GGGGGGCTV CTV CTV CT V CT V E E E E EEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVEEE6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W G GGGGGGGGGGG GGGGGGGGGGGGGCTV CTV CTV CTV CTVCTV CTV CTV CTVCTV C T V CTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV CTV CTV CTVCTVCTVCTV CTVCTVCTVCTV CTVCTV CTV C T V CTVCTVCTV CTV CTVCTVCTVCTVCTVCTV CTV CTV CTV CTVCTV CTV CTVCTVCTVEE E E EE E E E E E E E EEEEEEEEEEEEEEE E E E E EEE E E EEEEEEEE EEEE E E E E E E E E E E EEEEEEEEEEEE E E E E E E EEE E E CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC CT C C CABLE C TC T C C C T C VAULT ELEC X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXW W W WW WXXXXX XXXXXXS W W G G G G G G G G G G GGGXE E E E E E E E E E E GGGG G GG8" SS 8" SS 8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSWWWW WWWWXXXXXXXX X X X X X X X X X X X X X X X X6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECEXISTING 10' CONCRETE PAN TO BE REMOVED EXISTING GROUNDED ELECTRIC AND CABLE TO BE REMOVED EXISTING PEDESTRIAN RAMP TO BE REMOVED EXISTING SANITARY SEWER MANHOLES TO REMAIN ±32 LF 30" VERTICAL CURB & GUTTER, SIDEWALK, AND RAMP TO BE REMOVED EXISTING HEADWALL & OVERFLOW WEIR TO REMAIN ±39 LF 2' CONCRETE PAN TO BE REMOVED PROPOSED SAWCUT (TYP.) PROPOSED SAWCUT (TYP.) EXISTING BUILDINGS TO REMAIN (TYP.) EXISTING 8" SANITARY SEWER TO BE REMOVED EXISTING FIRE HYDRANT TO REMAIN EXISTING 20' SANITARY SEWER EASEMENT TO BE VACATED BY PLAT EXISTING 1' OUTLOT TO BE VACATED BY PLAT EXISTING 2' CONCRETE PAN TO BE REMOVED EXISTING 2' CONCRETE PAN TO REMAIN EXISTING 6' SIDEWALK EXISTING 6' SIDEWALK EXI STI N G 6' SI D E W AL K EXISTING 20' SANITARY SEWER EASEMENT TO BE VACATED BY PLAT EXISTING STRIPING TO REMAIN EXISTING STRIPING TO REMAIN EXISTING 15' UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING 20' DRAINAGE & UTILTY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING 8" SANITARY SEWER EXISTING 8" SANITARY SEWER EXISTING 6" WATER MAIN OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER:BAILEY, MICHAEL2213 WOODFORD CT.OWNER:HAUAN, JAMES P/PATRICIA A2212 WOODFORD CT.OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. EXISTING 6' UTILITY EASEMENT TO BE VACATED BY PLAT EXISTING STORM DRAIN TO BE CAPPED AT HEADWALL OWNER: VILLAGES, LTD. 400 IMPALA CIR. ±24' FL-FL (TYP.) IMPALA CIRCLE ±90 LF 30" VERTICAL CURB & GUTTER ISLAND TO BE REMOVED EXISTING STRIPING TO BE REMOVED EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) REMOVE BUSHES FROM EXISTING CUL-DE-SAC ISLAND CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 C 103DEMOLITION PLAN EXISTING CONDITIONS & 4 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.ALL PUBLIC SIDEWALKS, DRIVEWAYS, AND RAMPS, EXISTING OR PROPOSED, ADJACENT OR WITHIN THE SITE, SHALL MEET ADA STANDARDS OR BE RECONSTRUCTED TO CONFORM TO CURRENT ADA STANDARDS AS A PART OF THIS PROJECT. 7.CONTRACTOR SHALL COORDINATE WITH TRAFFIC CONTROL STAFF TO ENSURE UTILITY INSTALLATIONS WITHIN IMPALA DRIVE DO NOT IMPEDE SCHOOL AND NEIGHBORHOOD ACCESS. 8.SEE LANDSCAPING PLANS SHEETS L600 - L601 FOR DETAILED TREE MITIGATION INVENTORY AND DBH DIMENSIONS. EXISTING OVERHEAD UTILITY OHE ORIGINAL FIELD SURVEY: NORTHERN ENGINEERING PROJECT NO. 370-005 DATE: DECEMBER 28, 2021 ADDITIONAL FIELD SURVEY: NORTHERN ENGINEERING PROJECT NO. 370-005 DATE: MARCH 17, 2022 ASPHALT REMOVAL ASPHALT PATCH CONCRETE REMOVAL KEYMAP C 102 C 103 C 104 MATCH LINE - SEE SHEET C 104 MATCH LINE - SEE SHEET C 102 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVGGGGGGGG G G G G GGGGGGGCTVCTVCTV CTVCTVCTVCTV CTVCTVCTVCTVCTV CTVCTVCTVCTVCTV CTV CTV CTV CTVCTV CTV CTVCTVCTVEEE E E EEEEEEE EE E E E E EEEEEEEE E E EEE E E XXXXXX X XXXXXXXXGGGGGGGGGGG XXXXXXCABLE C TC C T C HYDVAULT F.O.XXXXXXXXXXXXXXXXXXXXXXG G G G G G E E E E E GGGGG S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSIRR IRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR C D SS D 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTCTVCTVCTVCTVCTVCTVCTVCTVCTVGGGGGGGGGGFOFOFOFOFOFOFOFOFOFOFOFO FOEEEEE E 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECW W SS SS SS WEST MULBERRY STREET EXISTING 30" VERTICAL CURB & GUTTER W/ ATTACHED SIDEWALK TO BE REMOVED EXISTING 2' SIDEWALK CULVERT TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING TREE TO REMAIN EXISTING 5' CONCRETE TRAIL TO BE REMOVED ±32 LF 30" VERTICAL CURB & GUTTER, SIDEWALK, AND RAMP TO BE REMOVED PROPOSED SAWCUT (TYP.) PROPOSED SAWCUT (TYP.) EXISTING BUILDING TO REMAIN (TYP.) EXISTING 2' CONCRETE PAN TO REMAIN EXI STI N G 6' SI D E W AL K EXISTING 20' SANITARY SEWER EASEMENT TO BE VACATED BY PLAT EXISTING STRIPING TO REMAIN EXISTING GAS LINE TO BE RELOCATED EXISTING 15' UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING 20' DRAINAGE & UTILTY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT DRIVEWAY APPROACH TO BE REMOVED EXISTING 18" VERTICAL CURB & GUTTER TO REMAIN EXISTING 10" SANITARY SEWER EXISTING 8" WATER MAIN EXISTING 36" STORM DRAIN EXISTING 15" STORM DRAIN TO REMAIN EXISTING SANITARY SERVICE TO BE REMOVED (APPROX.) EXISTING WATER SERVICE TO BE REMOVED (APPROX.) EXISTING 8" SANITARY SEWER EXISTING 6" WATER MAIN EXISTING 8" SANITARY SEWER EXISTING FIRE HYDRANT TO REMAIN PROPOSED SAWCUT (TYP.) OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. OWNER: VILLAGES, LTD. 400 IMPALA CIR. EXISTING 18" CLAY IRRIGATION LINE TO REMAIN (APPROX.) OWNED BY CITY OF FORT COLLINS PARKS DEPARTMENT EXISTING HEADWALL & OVERFLOW WEIR TO REMAIN EXISTING GROUNDED ELECTRIC AND FIBER OPTIC TO REMAIN EXISTING 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT FOR REFERENCE: REPLACEMENT OF IRRIGATION LATERAL BY CITY OF FORT COLLINS PARKS DEPT. POSSIBLE DURING CONSTRUCTION CONTRACTOR TO COORDINATE WITH CITY OF FORT COLLINS EXISTING 40' ACCESS, UTILITY, & DRAINAGE EASEMENT REC. NO. 20100011476 TO REMAIN ±90 LF 30" VERTICAL CURB & GUTTER ISLAND TO BE REMOVED EXISTING STRIPING TO BE REMOVED EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING EASEMENT EXCLUSION TO BE VACATED EXISTING EASEMENT EXCLUSION EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT EXISTING 3 4" WATER SERVICE TO BE ABANDONED AT MAIN (TYP.) UTILITY EASEMENT REC. NO. 90665430 TO BE VACATED BY PLAT 15' ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 TO BE VACATED BY PLAT INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) REMOVE BUSHES FROM EXISTING CUL-DE-SAC ISLAND EXISTING 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 C 104DEMOLITION PLAN EXISTING CONDITIONS & 5 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.ALL PUBLIC SIDEWALKS, DRIVEWAYS, AND RAMPS, EXISTING OR PROPOSED, ADJACENT OR WITHIN THE SITE, SHALL MEET ADA STANDARDS OR BE RECONSTRUCTED TO CONFORM TO CURRENT ADA STANDARDS AS A PART OF THIS PROJECT. 7.CONTRACTOR SHALL COORDINATE WITH TRAFFIC CONTROL STAFF TO ENSURE UTILITY INSTALLATIONS WITHIN IMPALA DRIVE DO NOT IMPEDE SCHOOL AND NEIGHBORHOOD ACCESS. 8.SEE LANDSCAPING PLANS SHEETS L600 - L601 FOR DETAILED TREE MITIGATION INVENTORY AND DBH DIMENSIONS. EXISTING OVERHEAD UTILITY OHE ORIGINAL FIELD SURVEY: NORTHERN ENGINEERING PROJECT NO. 370-005 DATE: DECEMBER 28, 2021 ADDITIONAL FIELD SURVEY: NORTHERN ENGINEERING PROJECT NO. 370-005 DATE: MARCH 17, 2022 ASPHALT REMOVAL ASPHALT PATCH CONCRETE REMOVAL KEYMAP C 102 C 103 C 104 MATCH LINE - SEE SHEET C 103 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: C CCCCCCCCCCCCCC C C C C C CC XXXXXXXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXX X 4 4 6 6 4 44 N:130065.51 E:182625.45 N:130064.72 E:182697.26 N:129913.35 E:182623.74 N:129912.57 E:182695.74 N:129892.35 E:182758.98 N:130063.84 E:182760.94 N:130063.02 E:182832.19 N:129861.34 E:182625.58 N:129807.82 E:182628.97 N:129804.19 E:182788.83 N:129859.58 E:182780.44 7' SIDEWALK 6' SIDEWALK 7' SIDEWALK8' S IDEWALK 5' SIDEWALK6' SIDEWALK6' SIDEWALK8.5' SIDEWALKN:129891.54 E:182830.23 IMPALA CIRCLE SOUTH IMPALA DRIVE6' SIDEWALK 5' SIDEWALKEXISTING 6' SIDEWALK EXISTING 6' SIDEWALK OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT IMPALA CIRCLE5' SIDEWALKOWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. 3' CRUSHER FINES 3 1 1 6' DECORATIVE CONCRETE CROSSING 3 3 3 P P P D D D EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION 22 1 2 2 2 22 2 2 1 4 1 PROPOSED TRASH ENCLOSURE PROPOSED TRASH ENCLOSURE RAIN GARDEN BIOMEDIA AREA PROPOSED 3' CONCRETE RUNDOWN W/ FOREBAY PROPOSED SAWCUT (TYP.) PROPOSED SAWCUT (TYP.) PROPOSED SAWCUT (TYP.) 1 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT ±31' FL-FL (TYP.) ±23' FL-FL (TYP.) 8.5' (TYP.) 9' (TYP.) 9' 9' (TYP.) 18' (TYP.) 18' (TYP.) 9' (TYP.) 18' (TYP.) 9' (TYP.) 9' (TYP.)18' (TYP.) 9'9' (TYP.) 18' (TYP.) 8' (TYP.) 15' (TYP.) 8' (TYP.)15' (TYP.) 20' FL-FL 18'8.5' (TYP.)18' 23' (TYP.)7' (TYP.) 18' (TYP.) PUBLIC ACCESS EASEMENT (WIDTH VARIES) 15' (TYP.) 8' (TYP.) ADA RAMP W/ HANDRAILS 1 1 9' (TYP.) 18' (TYP.) 9' (TYP.) 18' (TYP.) 9' (TYP.) 18' (TYP.) 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 4 6 PROPOSED STRIPING (TYP.) 5 EXISTING 30" DRIVE-OVER CURB & GUTTER TIE IN TO EXISTING 8' SIDEWALK 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 18' WIDE OVERFLOW WEIR 2 EASEMENT EXCLUSION8.5' SIDEWALK±4.5' GRAVEL PATH ADA RAMP W/ HANDRAILS ADA RAMP W/ HANDRAILS PROPOSED ROCK WALL STEPS 3A 3A 2R 2L 2 1 1 PROPOSED 31" DRIVE-OVER CURB & GUTTER PROPOSED SIGN "PRIVATE DRIVE NOT A THROUGH STREET" PROPOSED SIGN "PRIVATE DRIVE NOT A THROUGH STREET" 2 2 CONTRACTOR TO RESTORE ALL SHARED LANE STRIPING ON SOUTH IMPALA DRIVE R52' R25' R25' R25' R25' R3'R3'R3' R3' R3' R2' R3' R3'R3'R3' 8.5' PROPOSED FIRE DEPARTMENT WAYFINDING SIGN 15' 12' 12' R25' R25' 15' 3 6' DECORATIVE CONCRETE CROSSING INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) 10' ACCESS TO POUDRE SCHOOL SPORTS FIELDS ±4.5' GRAVEL PATH D D D PROPOSED PRIVATE STREET LIGHT (TYP.) PROPOSED PRIVATE STREET LIGHT (TYP.) 1 1 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 201 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. 7.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK. 8.ATTACHED WALK WIDTHS ARE FROM FLOWLINES. 9.SINGLE POINT CURB TRANSITIONS ARE 6'. 10.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION. 11.ALL CURB & GUTTER CALLS ARE FLOWLINE UNLESS OTHERWISE NOTED. 12.ALL FIRE LANES SHALL BE PAVED AS FLAT ALL-WEATHER DRIVING SURFACE CAPABLE OF SUPPORTING 40 TONS. 13.ALL PUBLIC SIDEWALKS, DRIVEWAYS, AND RAMPS, EXISTING OR PROPOSED, ADJACENT OR WITHIN THE SITE, SHALL MEET ADA STANDARDS OR BE RECONSTRUCTED TO CONFORM TO CURRENT ADA STANDARDS AS A PART OF THIS PROJECT. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE / / / / / / / /PROPOSED EDGE OF PAVEMENT PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: PARKING ASPHALT PAVING PRIVATE CONCRETE FLATWORK SITE SIGN LEGEND SIGNAGE NOTE: 1.SIGN LOCATIONS SHOWN ARE APPROXIMATE. FINAL LOCATION MAY VARY. 2.ADDITIONAL SIGNS FOR 3A CONFIGURATION ARE TO BE ORIENTED PERPENDICULAR TO R1-1 SIGN FOR VISIBILITY OF TRAFFIC APPROACHING FROM OTHER DIRECTIONS. MAY REQUIRE INSTALLATION OF IDENTICAL SIGNS ON BOTH SIDES OF POST. RESERVED PARKING 2 P D C 2 4 5 6 18" VERTICAL INFLOW CURB & GUTTER 18" VERTICAL OUTFALL CURB & GUTTER PARALLEL ACCESS RAMP DIRECTIONAL ACCESS RAMP COMBINATION ACCESS RAMP X' CONCRETE PAN PUBLIC CONCRETE PAVING PRIVATE CONCRETE PAVING P FIRE LANE 1' SIDEWALK CHASE 2' SIDEWALK CHASE X 2' CONCRETE TRICKLE PAN 1 1 P0TS DRIVE AISLE ASPHALT PAVING ASPHALT PATCH 74' SIDEWALK CULVERT 330" VERTICAL CURB & GUTTER GRAVEL SIDEWALK P0TS Sample 2400 PRIVATELY MAINTAINED St NO OUTLET P FIRE LANE P FIRE LANE 2L 2R 43A3 KEYMAP C 200CIVIL SITE PLAN 6 C 200 C 201 C 202 X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X6 6 N:129891.54 E:182830.23 5' SIDEWALKEXISTING 6' SIDEWALK EXISTING 6' SIDEWALK EXI STI N G 6' SI D E W AL K OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/PATRICIA A 2212 WOODFORD CT. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. OWNER: VILLAGES, LTD. 400 IMPALA CIR. IMPALA CIRCLE5' SIDEWALK3' CRUSHER FINES 3' C R U S H E R FI N E S 3 6' DECORATIVE CONCRETE CROSSING 1 2 2 1 PROPOSED TRASH ENCLOSURE RAIN GARDEN BIOMEDIA AREA PROPOSED 3' CONCRETE RUNDOWN W/ FOREBAY EXISTING 2' CONCRETE PAN EXISTING STRIPING TO REMAIN PROPOSED SAWCUT (TYP.) ±23' FL-FL (TYP.) 9' (TYP.) 18' (TYP.) 9' (TYP.) 20' FL-FL PROPOSED BOULDER WALL EXISTING SIDEWALK CULVERT EXISTING HEADWALL & OVERFLOW WEIR EXISTING 30" VERTICAL CURB & GUTTER 6 6 PROPOSED STRIPING (TYP.) 5 PROPOSED 6" VERTICAL CURB 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED STRIPING (TYP.) PROPOSED 18' WIDE OVERFLOW WEIR ISLAND TO BE PAVED FLUSH WITH EXISTING CUL-DE-SAC PROPOSED 31" DRIVE-OVER CURB & GUTTER PAINT RED EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSIONEASEMENT EXCLUSION8.5' SIDEWALK±4.5' GRAVEL PATH 2L 2 R38' 18' 2 2 2 R3' R2' R3' PROPOSED FIRE DEPARTMENT WAYFINDING SIGN 15' 12' R25' R25' 3 6' DECORATIVE CONCRETE CROSSING INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) D D D PROPOSED PRIVATE STREET LIGHT (TYP.) NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 202 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. 7.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK. 8.ATTACHED WALK WIDTHS ARE FROM FLOWLINES. 9.SINGLE POINT CURB TRANSITIONS ARE 6'. 10.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION. 11.ALL CURB & GUTTER CALLS ARE FLOWLINE UNLESS OTHERWISE NOTED. 12.ALL FIRE LANES SHALL BE PAVED AS FLAT ALL-WEATHER DRIVING SURFACE CAPABLE OF SUPPORTING 40 TONS. 13.ALL PUBLIC SIDEWALKS, DRIVEWAYS, AND RAMPS, EXISTING OR PROPOSED, ADJACENT OR WITHIN THE SITE, SHALL MEET ADA STANDARDS OR BE RECONSTRUCTED TO CONFORM TO CURRENT ADA STANDARDS AS A PART OF THIS PROJECT. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE / / / / / / / /PROPOSED EDGE OF PAVEMENT PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: PARKING ASPHALT PAVING PRIVATE CONCRETE FLATWORK SITE SIGN LEGEND SIGNAGE NOTE: 1.SIGN LOCATIONS SHOWN ARE APPROXIMATE. FINAL LOCATION MAY VARY. 2.ADDITIONAL SIGNS FOR 3A CONFIGURATION ARE TO BE ORIENTED PERPENDICULAR TO R1-1 SIGN FOR VISIBILITY OF TRAFFIC APPROACHING FROM OTHER DIRECTIONS. MAY REQUIRE INSTALLATION OF IDENTICAL SIGNS ON BOTH SIDES OF POST. RESERVED PARKING 2 P D C 2 4 5 6 18" VERTICAL INFLOW CURB & GUTTER 18" VERTICAL OUTFALL CURB & GUTTER PARALLEL ACCESS RAMP DIRECTIONAL ACCESS RAMP COMBINATION ACCESS RAMP X' CONCRETE PAN PUBLIC CONCRETE PAVING PRIVATE CONCRETE PAVING P FIRE LANE 1' SIDEWALK CHASE 2' SIDEWALK CHASE X 2' CONCRETE TRICKLE PAN 1 1 P0TS DRIVE AISLE ASPHALT PAVING ASPHALT PATCH 74' SIDEWALK CULVERT 330" VERTICAL CURB & GUTTER GRAVEL SIDEWALK P0TS Sample 2400 PRIVATELY MAINTAINED St NO OUTLET P FIRE LANE P FIRE LANE 2L 2R 43A3 KEYMAP C 201CIVIL SITE PLAN 7 MATCH LINE - SEE SHEET C 200 C 200 C 201 C 202 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CCCCCXXXXXXXXXXXXXXXXXXXXXXXXXXXX975085 (NAVD88)5084 (NAVD88)5083 (NAVD88)5082 (NAVD88)4 N:129345.42 E:183120.97 N:129344.09 E:183189.96 N:129272.86 E:183188.59N:129274.19 E:183119.60 WEST MULBERRY STREET 5' SIDEWALK6' SIDEWALKEXI STI N G 6' SI D E W AL K OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR.OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. PROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED 15' ACCESS RAMP EASEMENT EXCLUSION 2 EXISTING 2' CONCRETE PAN EXISTING STRIPING TO REMAIN EXISTING 18" VERTICAL CURB & GUTTER PROPOSED 3' SIDEWALK CULVERT PROPOSED SAWCUT (TYP.) PROPOSED SAWCUT (TYP.) PROPOSED TYPE 1 DRIVEWAY APPROACH (PER LCUASS) 3 18' (TYP.) 8.5' (TYP.) 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT EXISTING HEADWALL & OVERFLOW WEIR TIE IN TO EXISTING 5' SIDEWALK EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING 2' CONCRETE PAN PROPOSED STRIPING (TYP.) EXISTING 30" VERTICAL CURB & GUTTER 5 8' (TYP.) 8'6'CONCRETE TRAIL6'CONCRETE TRAILPROPOSED SIGN "PRIVATE DRIVE NOT A THROUGH STREET" 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED STRIPING (TYP.) PROPOSED NON-LOCKING REMOVABLE BOLLARDS PROPOSED NON-LOCKING REMOVABLE BOLLARD P ISLAND TO BE PAVED FLUSH WITH EXISTING CUL-DE-SAC PROPOSED 31" DRIVE-OVER CURB & GUTTER PAINT RED PROPOSED 31" DRIVE-OVER CURB & GUTTER PAINT RED EASEMENT EXCLUSIONEASEMENT EXCLUSION EXISTING 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT R38' 18' 1 1 4 4 2 2 PROPOSED STRIPING (TYP.) R49' R49' R8' R25' R15' 3A 1 INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR HIGH-RISK FLOOD FRINGE 5083 (NAVD88)5084 (NAVD88)5085 (NAVD88)X-SEC #2303 - 5085.14' (NAVD88)X-SEC #1983 - 5081.71' (NAVD88)NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 201 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. 7.CURVES AND LINES ARE MEASURED AT FLOWLINE, CENTERLINE OR EDGE OF WALK. 8.ATTACHED WALK WIDTHS ARE FROM FLOWLINES. 9.SINGLE POINT CURB TRANSITIONS ARE 6'. 10.SIGN PLACEMENT SHALL BE PER THE LATEST EDITION OF MUTCD REGARDLESS OF PLAN LOCATION. 11.ALL CURB & GUTTER CALLS ARE FLOWLINE UNLESS OTHERWISE NOTED. 12.ALL FIRE LANES SHALL BE PAVED AS FLAT ALL-WEATHER DRIVING SURFACE CAPABLE OF SUPPORTING 40 TONS. 13.ALL PUBLIC SIDEWALKS, DRIVEWAYS, AND RAMPS, EXISTING OR PROPOSED, ADJACENT OR WITHIN THE SITE, SHALL MEET ADA STANDARDS OR BE RECONSTRUCTED TO CONFORM TO CURRENT ADA STANDARDS AS A PART OF THIS PROJECT. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE / / / / / / / /PROPOSED EDGE OF PAVEMENT PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: PARKING ASPHALT PAVING PRIVATE CONCRETE FLATWORK SITE SIGN LEGEND SIGNAGE NOTE: 1.SIGN LOCATIONS SHOWN ARE APPROXIMATE. FINAL LOCATION MAY VARY. 2.ADDITIONAL SIGNS FOR 3A CONFIGURATION ARE TO BE ORIENTED PERPENDICULAR TO R1-1 SIGN FOR VISIBILITY OF TRAFFIC APPROACHING FROM OTHER DIRECTIONS. MAY REQUIRE INSTALLATION OF IDENTICAL SIGNS ON BOTH SIDES OF POST. RESERVED PARKING 2 P D C 2 4 5 6 18" VERTICAL INFLOW CURB & GUTTER 18" VERTICAL OUTFALL CURB & GUTTER PARALLEL ACCESS RAMP DIRECTIONAL ACCESS RAMP COMBINATION ACCESS RAMP X' CONCRETE PAN PUBLIC CONCRETE PAVING PRIVATE CONCRETE PAVING P FIRE LANE 1' SIDEWALK CHASE 2' SIDEWALK CHASE X 2' CONCRETE TRICKLE PAN 1 1 P0TS DRIVE AISLE ASPHALT PAVING ASPHALT PATCH 74' SIDEWALK CULVERT 330" VERTICAL CURB & GUTTER GRAVEL SIDEWALK P0TS Sample 2400 PRIVATELY MAINTAINED St NO OUTLET P FIRE LANE P FIRE LANE 2L 2R 43A3 KEYMAP C 202CIVIL SITE PLAN 8 C 200 C 201 C 202 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 6Ŕ W 6" W 6" W 6" W6" W6" W6" W6" W 6" W 6" W EEEEE EEEGGG G G GGGGEE CTVCTVCTVCTVCTVCTVCTVE6" W 6" W 6" W GGGGG G GGGGGCTV CTVCTV CTV CTV CTVCTVCTVCTV CTVCTVCTVCTV CTVCTVCTVCTV CTV CTV CTVE EE E EEEE EE E E EEEE E E E EEEEE E EE GXXVAULT ELEC VAULT ELEC CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC CT C C CABLE C TC T C C C T C VAULT ELEC H YDVAULT F.O. X X X X X X XXXXXXXXXXXW WXX XXXXS W W G G G G G G G G G G G GXXXXE E E E E E E E E E E E 8" SS 8" SS 8" SS S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSIRRIRRIRR IRR IRR IRR IRR IRR W C S S S FO D D SS D S 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STST16Ŕ W16" W16" W16" W16" W16" W16" W16" W 16" W 16" W 16" W 16" W XXX X X X X X XXCTV CTV CTVGGGFOFOFOFOTTTTTGGG FO FOFOFOEE 8Ŕ W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECXXXXXXW FUDSWTT T E G GSGGGWFEEEEETSIRSWFF F IRIMPALA CIRCLE SOUTH IMPALA DRIVEWEST MULBERRY STREET IMPALA CIRCLE EXISTING 8" SANITARY SEWER EXISTING 16" WATER EXISTING 6" WATER EXISTING GAS LINE EXISTING 8" SANITARY SEWER EXISTING 15" STORM DRAIN EXISTING 36" STORM DRAIN EXISTING 8" WATER EXISTING 10" SANITARY SEWER PROPOSED SANITARY SEWER SERVICE (TYP.) PROPOSED WATER & FIRE SERVICES EXISTING 2' CONCRETE PAN 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' FL-FL PROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED 2' CONCRETE PAN EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION RAIN GARDEN 1 BIOMEDIA AREA ±31' FL-FL (TYP.) EXISTING 8" SANITARY SEWER EXISTING 6" WATER PROPOSED GAS LINE RELOCATION PROPOSED UNDERDRAIN PROPOSED POND OUTLET STRUCTURE PROPOSED WATER METER (TYP.) PROPOSED FIRE SERVICE (TYP.) PROPOSED SANITARY SERVICE (TYP.) EXISTING 2' CONCRETE PAN 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 3' CONCRETE RUNDOWN W/ FOREBAY PROPOSED 3' SIDEWALK CULVERT OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/ PATRICIA A 2212 WOODFORD CT. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. OLIVE STREET 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT EXISTING 18" CLAY IRRIGATION LINE (APPROX.) OWNED BY CITY OF FORT COLLINS PARKS DEPARTMENT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED 3' SIDEWALK CULVERT EXISTING HEADWALL & OVERFLOW WEIR PROPOSED BOULDER WALL BLANKET UTILITY & DRAINAGE EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 18' WIDE OVERFLOW WEIR PROPOSED SAWCUT (TYP.) EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION PROPOSED IRRIGATION TAP DETENTION POND 1 DETENTION POND 2 STORM DRAIN 1 SEE SHEET C 310 STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2-2 SEE SHEET C 312 STORM DRAIN 2-4 SEE SHEET C 312 NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 300OVERALL UTILITY PLAN 9 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP C 301 C 302 C 303 6Ŕ W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W EEEEEEEEEEE E EEEEEEEEEG G GGGG G GG G G GGGGGGGGGGEEEEEEE CTVCTVCTVCTVCTVEEE6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" WCTV CTV CTV CTV CTVCTV CTV CTV CTVCTVEE E E EE E E E EE E E E E E E E E E VAULT ELEC VAULT ELEC CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC C VAULT ELEC X X X X X X X G GXXXXXXXXXXXE E8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS W S S FO 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W X X X X X X XGGGGGGGGGFOFO FOFOFOFOFOFOFOFOFOFOTTTTTTTTTTTTT T G G XXXXXXXXXXXXXXXW FUD UD UD UDSWTT T G E E E G G G GGSIRRIR E EG G G GSW FF F IMPALA CIRCLE SOUTH IMPALA DRIVE26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' FL-FL 7' SIDEWALK 6' SIDEWALK 7' SIDEWALK8' S IDEWALK 5' SIDEWALK6' SIDEWALK6' SIDEWALK8.5' SIDEWALK5' SIDEWALKEASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION PROPOSED UNDERDRAIN PROPOSED 2" WATER METER PIT UPSIZE SERVICE TO 2.5" 5' AFTER METER PIT PROPOSED FIRE SERVICE (TYP.) EXISTING 8" SANITARY SEWER EXISTING 16" WATER EXISTING 8" SANITARY SEWER EXISTING 6" WATER PROPOSED 2' CONCRETE PAN EXISTING ELECTRIC LINES (TYP.) EXISTING 6' CONCRETE PAN EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING 8" SANITARY SEWER EXISTING SANITARY SEWER MANHOLE (TYP.) EXISTING 6" WATER EXISTING FIRE HYDRANT EXISTING FIBER OPTIC LINE EXISTING 16" WATER ±31' FL-FL (TYP.) ±24' FL-FL (TYP.)IMPALA CIRCLE PROPOSED AREA DRAIN (TYP.) PROPOSED AREA DRAIN (TYP.)5' SIDEWALKEXISTING CABLE TV LINE (TYP.) PROPOSED 1" WATER METER PIT EXISTING 6" WATER PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PUBLIC ACCESS EASEMENT (WIDTH VARIES) 3' CONCRETE TRAIL 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT RAIN GARDEN 1 BIOMEDIA AREA OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. PROPOSED FIRE SERVICE LINE (TYP.) 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 18' WIDE OVERFLOW WEIR PROPOSED TRANSFORMER (TYP.) EASEMENT EXCLUSION PROPOSED IRRIGATION TAP 8.5' SIDEWALKSAN SERVICE B INV. OUT=5088.76 (W) FG=5094.82 42.09 LF 6" PVC @ 5.00% SVC. CONNECTION B INV. IN=5085.99 (N) INV. IN=5086.66 (E) INV. OUT=5085.99 (S) FG=5094.12 SAN SERVICE A INV. OUT=5086.59 (E) FG=5091.93 89.75 LF 4" PVC @ 9.50% EXSSMH A INV. OUT=5077.48 (N) FG=5088.36 SVC. CONNECTION C INV. IN=5077.71 (N) INV. IN=5077.04 (W) INV. OUT=5077.04 (E) FG=5088.10 86.52 LF 6" PVC @ 6.00% SAN CLEANOUT C-1 INV. IN=5082.90 (W) INV. OUT=5082.90 (S) FG=5088.99 57.72 LF 6" PVC @ 6.00% SAN SERVICE C INV. OUT=5086.36 (E) FG=5091.62 82.34 LF 4" PERFORATED PVC @ 0.50% 13.13 LF 12" HDPE @ 0.50% FES 1-1 INV. IN=5084.82 (W) FG=5084.82 CLEANOUT 1-3 INV. OUT=5085.30 (E) FG=5086.40 INLET 1-2 (12" DOME BASIN) INV. IN=5084.88 (W) INV. OUT=5084.88 (E) FG=5087.40 PROPOSED 1" WATER SERVICE PROPOSED 2.5" WATER SERVICE STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2-2 SEE SHEET C 312 STORM DRAIN 2-4 SEE SHEET C 312 INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) ROTATE EXISTING MANHOLE CONE SUCH THAT RIM AVOIDS ADA RAMP GRADE BREAK. IF MANHOLE RISER IS CONCENTRIC, REPLACE WITH ECCENTRIC RISER. PROPOSED PRIVATE STREET LIGHT (TYP.) SVC. CONNECTION A INV. IN=5077.40 (S) INV. IN=5078.07 (W) FG=5088.32 6' SIDEWALK PROPOSED 2" WATER METER PIT UPSIZE SERVICE TO 2.5" 5' AFTER METER PIT NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE SHEET C 302 C 301UTILITY PLAN 10 C 301 C 302 C 303 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: 6" W 6" W 6" W6" W6" W6" W6" W6" WG G GGGG G GG G G G G G G GEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVEEE6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W G GGGGGGGGGGG GGGGGGGGGGGGGCTV CTV CTV CTV CTVCTV CTV CTV CTVCTV C T V CTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV CTV CTV CTVCTVCTVCTV CTVCTVCTVCTV CTVCTV CTV C T V CTVCTVCTV CTV CTVCTVCTVCTVCTVCTV CTV CTV CTV CTVCTV CTV CTVCTVCTVEE E E EE E E E E E E E EEEEEEEEEEEEEEE E E E E EEE E E EEEEEEEE EEEE E E E E E E E E E E EEEEEEEEEEEE E E E E E E EEE E E CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC CT C C CABLE C TC T C C C T C VAULT ELEC X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXW W W WW WXXXXX XXXXXXS W W G G G G G G G G G GXE E E E E E E E E E E GGGG G GG8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSXXXXXXXX X X X X X X X X X X X X X X X X6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECUD UD UD UD T EEEEE G G G26' FL-FL PROPOSED 2' CONCRETE PAN 5' SIDEWALKPROPOSED UNDERDRAIN PROPOSED POND OUTLET STRUCTURE PROPOSED 2" WATER METER PIT UPSIZE SERVICE TO 2.5" 5' AFTER METER PIT EXISTING 8" SANITARY SEWER EXISTING CONCRETE PAN EXISTING 8" SANITARY SEWER PROPOSED 2' CONCRETE PAN EXISTING 6" WATER EXISTING 8" SANITARY SEWER EXISTING ELECTRIC LINES (TYP.)EXISTING GAS LINE (TYP.) EXISTING BUILDINGS (TYP.) EXISTING 6' CONCRETE PAN EXISTING FIRE HYDRANT EXISTING 2' CONCRETE PAN EXISTING CABLE TV LINE (TYP.) ±24' FL-FL (TYP.)IMPALA CIRCLE5' SIDEWALKEXISTING CABLE TV LINE (TYP.) EXISTING CABLE TV LINE (TYP.) 3' CONCRETE TRAIL 3' C O N C R E T E T R AI L PROPOSED BOULDER WALL DETENTION POND 1 RAIN GARDEN 1 BIOMEDIA AREA EXISTING SIDEWALK CULVERT EXISTING HEADWALL & OVERFLOW WEIR REMOVE EXISTING ORIFICE PLATE REPLACE WITH SOLID PLATE OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/PATRICIA A 2212 WOODFORD CT.OWNER:SIKORSKI, MITCHELL ANDREW2213 W MAGNOLIA CT.OWNER:STEADMAN, VIVIAN LOUISE2212 W MAGNOLIA CT.OWNER: VILLAGES, LTD. 400 IMPALA CIR. 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 18' WIDE OVERFLOW WEIR PROPOSED TRANSFORMER (TYP.) ADJUST MANHOLE CONE ELEVATION TO MATCH FLUSH ISLAND EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSIONEASEMENT EXCLUSION8.5' SIDEWALK30' 89.75 LF 4" PVC @ 9.50% EXSSMH A INV. OUT=5077.48 (N) FG=5088.36 SVC. CONNECTION C INV. IN=5077.71 (N) INV. IN=5077.04 (W) INV. OUT=5077.04 (E) FG=5088.10 86.52 LF 6" PVC @ 6.00% 82.34 LF 4" PERFORATED PVC @ 0.50% 13.13 LF 12" HDPE @ 0.50% FES 1-1 INV. IN=5084.82 (W) FG=5084.82 CLEANOUT 1-3 INV. OUT=5085.30 (E) FG=5086.40 INLET 1-2 (12" DOME BASIN) INV. IN=5084.88 (W) INV. OUT=5084.88 (E) FG=5087.40 STORM DRAIN 1 SEE SHEET C 310 CUT BACK EXISTING PIPE INSTALL SCOURSTOP MAT INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) ROTATE EXISTING MANHOLE CONE SUCH THAT RIM AVOIDS ADA RAMP GRADE BREAK. IF MANHOLE RISER IS CONCENTRIC, REPLACE WITH ECCENTRIC RISER. PROPOSED PRIVATE STREET LIGHT (TYP.) SVC. CONNECTION A INV. IN=5077.40 (S) INV. IN=5078.07 (W) FG=5088.32 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 MATCH LINE - SEE SHEET C 303 C 302UTILITY PLAN 11 MATCH LINE - SEE SHEET C 301 C 301 C 302 C 303 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVGGGGGGGG G G G G GGGGGGGCTVCTVCTV CTVCTVCTVCTV CTVCTVCTVCTVCTV CTVCTVCTVCTVCTV CTV CTV CTV CTVCTV CTV CTVCTVCTVEEE E E EEEEEEE EE E E E E EEEEEEEE E E EEE E E GGGGGXXXXXXCABLE C TC C T C HYDVAULT F.O.XXXXXXXXXXXXXXXXXXXXXXG G G G G G E E E E E GGGGG S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSIRR IRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR C D SS D 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTCTVCTVCTVCTVCTVCTVCTVCTVCTVGGGGGGGGGGFOFOFOFOFOFOFOFOFOFOFOFO FOEEEEE E 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECSGGGGGGGWFEEEEEEEEEEEEEEETIR WEST MULBERRY STREET PROPOSED LANDSCAPE WALL W/ HANDRAIL 6' SIDEWALKEASEMENT EXCLUSION EXISTING 15" STORM DRAIN PROPOSED 1" WATER SERVICE EXISTING 8" SANITARY SEWER EXISTING 6" WATER EXISTING 8" SANITARY SEWER PROPOSED 3' SIDEWALK CULVERT EXISTING 36" STORM DRAIN EXISTING GAS LINE EXISTING 10" SANITARY SEWER EXISTING 8" WATER EXISTING BUILDINGS (TYP.) EXISTING FIBER OPTIC LINE EXISTING 2' CONCRETE PAN EXISTING SANITARY SEWER MANHOLE (TYP.) EXISTING CABLE TV LINE (TYP.) 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT 51.5' EMERGENCY ACCESS EASEMENT PROPOSED GAS LINE RELOCATION EXISTING STORM DRAIN MANHOLE (TYP.) EXISTING 18" CLAY IRRIGATION LINE (APPROX.) OWNED BY CITY OF FORT COLLINS PARKS DEPARTMENT PROPOSED SCOURSTOP MAT DETENTION POND 2 OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR.OWNER:SIKORSKI, MITCHELL ANDREW2213 W MAGNOLIA CT.OWNER:GODING, BRYAN T.2218 W MULBERRY ST.OWNER: VILLAGES, LTD. 400 IMPALA CIR. PROPOSED 2' SIDEWALK CHASE 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 6'CONCRETE TRAIL6'CONCRETE TRAILPROPOSED FIRE SERVICE PROPOSED 1" WATER METER PIT EXISTING HEADWALL & OVERFLOW WEIR ADJUST MANHOLE CONE ELEVATION TO MATCH FLUSH ISLAND EASEMENT EXCLUSIONEASEMENT EXCLUSION 24' EMERGENCY ACCESS EASEMENT FOR REFERENCE: REPLACEMENT OF IRRIGATION LATERAL BY CITY OF FORT COLLINS PARKS DEPT. POSSIBLE DURING CONSTRUCTION CONTRACTOR TO COORDINATE WITH CITY OF FORT COLLINS SVC. CONNECTION D INV. IN=5073.69 (S) INV. IN=5074.36 (E) INV. OUT=5073.69 (N) FG=5084.79 47.16 LF 4" PVC @ 12.00% SAN SERVICE D INV. OUT=5080.02 (W) FG=5085.15 STORM DRAIN 1 SEE SHEET C 310 INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) PROPOSED IRRIGATION TAP NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 MATCH LINE - SEE SHEET C 302 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 303UTILITY PLAN 12 C 301 C 302 C 303 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: GGGG G G G G CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVEEE EE EE EEE E EEEG XXCCTCCCABLECTCHY DVAULTF.O.XXXXXXXXXXXXXXXWWSWGGGGGGEEEEEE8" SSS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SSIRR IRR IRR IRR CDSS10" SS10" SS10" SS10" SS10" SS10" SSSTSTSTSTSTSTSTXXXXXXX XCTVCTVCTVGGGFOFOFOFOEE8" W8" W8" W8" W8" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W ELECSGGGWFEEE ETIR OUTLET 1-5 STA 15+76.34 N: 129825.57 E: 183216.52 FES 1-1 STA 10+00.00 N: 129268.49 E: 183211.51 CLEANOUT 1-2 STA 10+17.95 N: 129281.04 E: 183224.35 13.98 LF 15" HDPE @ 0.50% 400.00 LF 15" HDPE @ 0.50%17.95 LF 15" HDPE @ 0.30% STMH 1-4 (FLAT TOP) STA 15+62.36 N: 129825.41 E: 183230.50 144.41 LF 15" HDPE @ 0.30% STMH 1-3 (FLAT TOP) STA 11+62.36 N: 129425.43 E: 183225.98WEST MULBERRY STREETPROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED 2' CONCRETE PANEASEMENT EXCLUSION EXISTING 15" STORM DRAIN EXISTING CONCRETE PAN EXISTING 36" STORM DRAIN EXISTING STORM DRAIN MANHOLE (TYP.) PROPOSED BOULDER WALL DETENTION POND 1 DETENTION POND 2 OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/PATRICIA A 2212 WOODFORD CT. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT.OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. OWNER: VILLAGES, LTD. 400 IMPALA CIR.EXISTING HEADWALL & OVERFLOW WEIR EASEMENT EXCLUSION EASEMENT EXCLUSION 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT IMPALA CIRCLE 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) 5060 5065 5070 5075 5080 5085 5090 5095 5100 5060 5065 5070 5075 5080 5085 5090 5095 5100 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+505082.945085.535085.335083.23FES 1-1STA 10+00.00INV. 5080.21 (NE)17.95 LF 15" HDPE @ 0.30% 400.00 LF 15" HDPE @ 0.50% 13.98 LF 15" HDPE @ 0.50%OUTLET 1-5STA 15+76.34FL. EL 5084.9±INV. OUT 5082.77 (E)EXISTING GROUNDPROPOSED GROUND EXISTING GROUND PROPOSED GROUNDSTMH 1-3 (FLAT TOP)STA 11+62.36RIM 5083.5±INV. IN 5080.70 (N)INV. OUT 5080.70 (S)STMH 1-4 (FLAT TOP)STA 15+62.36RIM 5085.2±INV. IN 5082.70 (W)INV. OUT 5082.70 (S)STA.=11+90.76 EXPECTED CROSSING FOR IRRIGATION LATERAL UNABLE TO LOCATE 144.41 LF 15" HDPE @ 0.30%CLEANOUT 1-2STA 10+17.95INV. 5080.26 (N)INV. 5080.26 (SW)100-YR HGL KEYMAP C 310PLAN & PROFILESTORM DRAIN 113 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: STORM DRAIN 1 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS STORMWATER CRITERIA MANUAL (FCSCM), LATEST EDITION. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: INLET SCHEDULE Inlet/Basin ID Inlet Size Grate Type INLET 1-2 (UDRAIN)12" Nyloplast Basin 12" Dome BASIN 2-3 12" Nyloplast Basin 12" Dome BASIN 2-5 12" Nyloplast Basin 12" Dome BASIN 2-6 8" Nyloplast Basin 8" Dome BASIN 2-7 8" Nyloplast Basin 8" Dome BASIN 2-8 8" Nyloplast Basin 8" Dome BASIN 2-9 8" Nyloplast Basin 8" Dome BASIN 2-10 8" Nyloplast Basin 8" Dome BASIN 2-2.4 8" Nyloplast Basin 8" Dome BASIN 2-2.1.1 8" Nyloplast Basin 8" Dome BASIN 2-2.2.1 8" Nyloplast Basin 8" Dome BASIN 2-4.1 12" Nyloplast Basin 12" Dome BASIN 2-4.2 12" Nyloplast Basin 12" Dome FOR REFERENCE: REPLACEMENT OF IRRIGATION LATERAL BY CITY OF FORT COLLINS PARKS DEPT. POSSIBLE DURING CONSTRUCTION CONTRACTOR TO COORDINATE WITH CITY OF FORT COLLINS 6Ŕ W 6" W 6" W 6" W6" W6" W6" W6" W 6" W 6" W EEEEE EEEGGGGGEECTVE6" W VAULT ELEC VAULT ELEC CABLEVAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDXXXX8" SS S S FO 8" SS8" SS8" SS8" SS8" SS8" SS16Ŕ W16" W16" W16" W16" W16" W16" WGGGFOFOFOFOTTTTTW FSWSIR SW FF F BASIN 2-10 STA 13+91.15 N: 130065.23 E: 182617.45 BASIN 2-5 STA 12+22.06 N: 129896.14 E: 182616.84 BASIN 2-4 STA 12+09.29 N: 129884.02 E: 182620.84 BASIN 2-3 STA 11+55.61 N: 129883.36 E: 182674.51 BASIN 2-2 STA 10+81.36 N: 129882.45 E: 182748.76 PIPE END 2-1 STA 10+00.00 N: 129881.45 E: 182830.11 81.36 LF 12" HDPE @ 0.15% 74.25 LF 12" HDPE @ 0.75% 12.77 LF 12" HDPE @ 0.75% 26.23 LF 8" PVC @ 0.75% 53.67 LF 12" HDPE @ 0.75% BASIN 2-6 STA 12+48.29 N: 129922.38 E: 182616.93 31.85 LF 8" PVC @ 0.75% BASIN 2-7 STA 12+80.14 N: 129954.22 E: 182617.05 39.44 LF 8" PVC @ 0.75% BASIN 2-8 STA 13+19.58 N: 129993.67 E: 182617.19 32.79 LF 8" PVC @ 0.75% 38.78 LF 8" PVC @ 0.75% BASIN 2-9 STA 13+52.37 N: 130026.45 E: 182617.31 STORM DRAIN 2-2 SEE SHEET C 312 STORM DRAIN 2-4 SEE SHEET C 312 IMPALA CIRCLE EASEMENT EXCLUSION EASEMENT EXCLUSION EXISTING 8" SANITARY SEWER 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT EASEMENT EXCLUSION SOUTH IMPALA DRIVE5070 5075 5080 5085 5090 5095 5100 5105 5110 5070 5075 5080 5085 5090 5095 5100 5105 5110 9+5010+0011+0012+0013+0014+0014+50 5088.135089.265090.175090.255090.145090.185092.805092.325092.495092.995094.235094.515094.585094.595094.745095.035095.155095.08PIPE END 2-1STA 10+00.00FL. EL 5089.7±INV. IN 5088.50 (W)81.36 LF 12" HDPE @ 0.15%BASIN 2-2STA 10+81.36FL. EL 5089.8±INV. IN 5088.62 (W)INV. IN 5088.62 (N)INV. OUT 5088.62 (E)74.25 LF 12" HDPE @ 0.75%BASIN 2-3STA 11+55.61FL. EL 5092.1±INV. IN 5089.18 (W)INV. OUT 5089.18 (E)53.67 LF 12" HDPE @ 0.75%BASIN 2-10STA 13+91.15FL. EL 5095.2±INV. OUT 5091.28 (S)26.23 LF 8" PVC @ 0.75%BASIN 2-5STA 12+22.06FL. EL 5094.1±INV. IN 5090.01 (N)INV. OUT 5089.68 (S)12.77 LF 12" HDPE @ 0.75%BASIN 2-4STA 12+09.29FL. EL 5093.2±INV. IN 5089.58 (N)INV. IN 5089.58 (S)INV. OUT 5089.58 (E)EXISTING GROUNDPROPOSED GROUND EXISTING GROUND PROPOSED GROUNDBASIN 2-9STA 13+52.37FL. EL 5095.0±INV. IN 5090.99 (N)INV. OUT 5090.99 (S)38.78 LF 8" PVC @ 0.75% 32.79 LF 8" PVC @ 0.75%BASIN 2-8STA 13+19.58FL. EL 5094.7±INV. IN 5090.74 (N)INV. OUT 5090.74 (S)BASIN 2-7STA 12+80.14FL. EL 5094.5±INV. IN 5090.45 (N)INV. OUT 5090.45 (S)BASIN 2-6STA 12+48.29FL. EL 5094.5±INV. IN 5090.21 (N)INV. OUT 5090.21 (S)39.44 LF 8" PVC @ 0.75% 31.85 LF 8" PVC @ 0.75% 6" PVC SANITARY STA.=13+16.35 INV.=5088.56 18" MIN. 100-YR HGL KEYMAP C 311PLAN & PROFILESTORM DRAIN 214 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: STORM DRAIN 2 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS STORMWATER CRITERIA MANUAL (FCSCM), LATEST EDITION. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: INLET SCHEDULE Inlet/Basin ID Inlet Size Grate Type INLET 1-2 (UDRAIN)12" Nyloplast Basin 12" Dome BASIN 2-3 12" Nyloplast Basin 12" Dome BASIN 2-5 12" Nyloplast Basin 12" Dome BASIN 2-6 8" Nyloplast Basin 8" Dome BASIN 2-7 8" Nyloplast Basin 8" Dome BASIN 2-8 8" Nyloplast Basin 8" Dome BASIN 2-9 8" Nyloplast Basin 8" Dome BASIN 2-10 8" Nyloplast Basin 8" Dome BASIN 2-2.4 8" Nyloplast Basin 8" Dome BASIN 2-2.1.1 8" Nyloplast Basin 8" Dome BASIN 2-2.2.1 8" Nyloplast Basin 8" Dome BASIN 2-4.1 12" Nyloplast Basin 12" Dome BASIN 2-4.2 12" Nyloplast Basin 12" Dome 6Ŕ W6" W6" W6" W6" W6" WE E E E E E E W16" W16" W16" W16" WXXXXXWFSWS S WFFFBASIN 2-2.4 STA 11+83.75 N: 130062.97 E: 182742.98 BASIN 2-2.2.1 INV. OUT=5089.80 (W) FG=5092.04 BASIN 2-2.1 STA 10+32.04 N: 129914.49 E: 182749.15 BASIN 2-2.2 STA 11+66.65 N: 130049.09 E: 182750.80 BASIN 2-2.3 STA 11+72.45 N: 130054.88 E: 182750.87 BASIN 2-2.1.1 INV. OUT=5089.15 (E) FG=5089.29 32.04 LF 12" HDPE @ 0.50% 134.61 LF 8" PVC @ 0.50% 5.80 LF 8" PVC @ 0.50% 11.30 LF 8" PVC @ 0.50% 5.05 LF 8" PVC @ 0.50% 6.83 LF 8" PVC @ 0.50% BASIN 2-2 STA 10+00.00 N: 129882.45 E: 182748.76 STORM DRAIN 2 SEE SHEET C 311STORM DRAIN 2-4 SEE THIS SHEET - RIGHT EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION IMPALA CIRCLE5070 5075 5080 5085 5090 5095 5100 5105 5110 5070 5075 5080 5085 5090 5095 5100 5105 5110 9+50 10+00 11+00 12+00 12+505092.195090.135090.475090.585091.345091.415091.415092.395093.185093.7332.04 LF 12" HDPE @ 0.50%BASIN 2-2.1STA 10+32.04FL. EL 5090.6±INV. IN 5089.12 (N)INV. IN 5089.12 (W)INV. OUT 5088.78 (S)134.61 LF 8" PVC @ 0.50%BASIN 2-2.4STA 11+83.75FL. EL 5092.9±INV. OUT 5089.87 (SE)11.30 LF 8" PVC @ 0.50%BASIN 2-2.3STA 11+72.45FL. EL 5090.5±INV. IN 5089.82 (NW)INV. OUT 5089.82 (S)5.80 LF 8" PVC @ 0.50%BASIN 2-2.2STA 11+66.65FL. EL 5090.5±INV. IN 5089.79 (N)INV. IN 5089.78 (E)INV. OUT 5089.79 (S)BASIN 2-2STA 10+00.00FL. EL 5089.8±INV. IN 5088.62 (W)INV. IN 5088.62 (N)INV. OUT 5088.62 (E)EXISTING GROUNDPROPOSED GROUND EXISTING GROUND PROPOSED GROUND 100-YR HGL 5070 5075 5080 5085 5090 5095 5100 5105 5110 5070 5075 5080 5085 5090 5095 5100 5105 5110 9+50 10+00 11+00 11+505094.475093.175092.795093.065092.595093.48BASIN 2-4STA 10+00.00FL. EL 5093.2±INV. IN 5089.58 (N)INV. IN 5089.58 (S)INV. OUT 5089.58 (E)BASIN 2-4.2STA 10+82.28FL. EL 5092.5±INV. OUT 5089.99 (N)47.52 LF 12" HDPE @ 0.50%BASIN 2-4.1STA 10+34.76FL. EL 5093.0±INV. IN 5089.75 (S)INV. OUT 5089.75 (N)34.76 LF 12" HDPE @ 0.50% EXISTING GROUNDPROPOSED GROUND EXISTING GROUND PROPOSED GROUND 100-YR HGL 6" WEEEEEGGGVAULTELECVAULTELECSFO8" SS 8" SS 8" SS 8" SS8" SS8" SS16Ŕ W 16" W 16" W 16" W FO FO FO FO TTTTTWF S FBASIN 2-4.1 STA 10+34.76 N: 129849.26 E: 182620.42 BASIN 2-4.2 STA 10+82.28 N: 129801.74 E: 182619.83 34.76 LF 12" HDPE @ 0.50% 47.52 LF 12" HDPE @ 0.50% BASIN 2-4 STA 10+00.00 N: 129884.02 E: 182620.84 STORM DRAIN 2 SEE SHEET C 311 SOUTH IMPALA DRIVEIMPALA CIRCLEKEYMAP C 312PLAN & PROFILESTORM DRAIN 215 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: STORM DRAIN 2-2 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS STORMWATER CRITERIA MANUAL (FCSCM), LATEST EDITION. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY INLET SCHEDULE: INLET SCHEDULE Inlet/Basin ID Inlet Size Grate Type INLET 1-2 (UDRAIN)12" Nyloplast Basin 12" Dome BASIN 2-3 12" Nyloplast Basin 12" Dome BASIN 2-5 12" Nyloplast Basin 12" Dome BASIN 2-6 8" Nyloplast Basin 8" Dome BASIN 2-7 8" Nyloplast Basin 8" Dome BASIN 2-8 8" Nyloplast Basin 8" Dome BASIN 2-9 8" Nyloplast Basin 8" Dome BASIN 2-10 8" Nyloplast Basin 8" Dome BASIN 2-2.4 8" Nyloplast Basin 8" Dome BASIN 2-2.1.1 8" Nyloplast Basin 8" Dome BASIN 2-2.2.1 8" Nyloplast Basin 8" Dome BASIN 2-4.1 12" Nyloplast Basin 12" Dome BASIN 2-4.2 12" Nyloplast Basin 12" Dome PROFILE SCALE: STORM DRAIN 2-4 LEFT RIGHT NORTH NORTH UD XXX X X X X X XXXXXXXXXXXXXXXXXXXXXD D D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTXXXXXXXXXXXXXXXXSOUTH IMPALA DRIVEWEST MULBERRY STREET IMPALA CIRCLE EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT ±31' FL-FL (TYP.) 26' FL-FL PROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED 2' CONCRETE PAN PROPOSED UNDERDRAIN PROPOSED POND OUTLET STRUCTURE EXISTING 15" STORM DRAIN OLIVE STREET FFE=96.15 FFE=95.48 FFE=93.25 FFE=92.25 FFE=91.25 FFE=86.02 RAIN GARDEN BIOMEDIA AREA DETENTION POND 1 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT IMPALA CIRCLE EXISTING DRAINAGE OUTFALL PROPOSED 3' SIDEWALK CULVERT EXISTING 36" STORM DRAIN DETENTION POND 2 PROPOSED 2' CONCRETE PAN PROPOSED 3' CONCRETE RUNDOWN W/ FOREBAY FFE=93.73 EXISTING 2' CONCRETE PAN EXISTING CONCRETE PAN EXISTING SIDEWALK CULVERT PROPOSED BOULDER WALL PROPOSED 3' SIDEWALK CULVERT OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/ PATRICIA A 2212 WOODFORD CT. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT BLANKET DRAINAGE & UTILITY EASEMENT (2) 6' CONCRETE TRAILS PROPOSED 18' WIDE OVERFLOW WEIR EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION FFE=92.23 PROPOSED ROCK WALL STEPS STORM DRAIN 1 SEE SHEET C 310 STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2-2 SEE SHEET C 312 STORM DRAIN 2-4 SEE SHEET C 312 NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 400OVERALL GRADING PLAN 16 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION, PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CANAL IMPORTATION FLOODPLAIN AND FLOODWAY. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. 7.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET, PER SECTION 10-45 OF CITY CODE. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. 8.STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK KEYMAP C 401 C 402 C 403 UD UD UD UD X X X X X X XXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXFFE=96.15 FFE=92.25 FFE=93.73 FFE=91.25 FFE=93.25 FFE=95.48 IMPALA CIRCLE SOUTH IMPALA DRIVE26' EMERGENCY ACCESS EASEMENT 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 20' FL-FL 7' SIDEWALK 6' SIDEWALK 7' SIDEWALK 6' SIDEWALK6' SIDEWALK8.5' SIDEWALK6' SIDEWALK 5' SIDEWALK8.5' SIDEWALKRAIN GARDEN BIOMEDIA AREA PROPOSED 6' CONCRETE PAN PROPOSED UNDERDRAIN EXISTING BUILDINGS (TYP.) EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION 5' SIDEWALK24' EMERGENCY ACCESS EASEMENT PROPOSED 2' CONCRETE PAN IMPALA CIRCLE ±31' FL-FL (TYP.) ±24' FL-FL (TYP.)5' SIDEWALKPUBLIC ACCESS EASEMENT (WIDTH VARIES) 3' CONCRETE TRAIL PROPOSED AREA DRAIN (TYP.) PROPOSED AREA DRAIN (TYP.) ADA RAMP W/ HANDRAILS EXISTING 30" DRIVE-OVER CURB & GUTTER EXISTING VERTICAL CURB & GUTTER PROPOSED SAWCUT (TYP.) PROPOSED 2' SIDEWALK CHASE94.5192.939 5 . 4 8 95.489 4 . 7 4 93.6394.3596.1595.5093.0593.7589.290.9%88.2288.5088.6090.1890.6092.8492.8888.27(88.00)(88.42)(92.69)(94.92)91.7592.7592.7592.7591.7590.7590.758 9 . 4 5 1.9%1.9%0.6%94.59(94.22)1.8%0.7%PROPOSED CHASE PROPOSED 3' CONCRETE PAN W/ FOREBAY1.9%1.5%1.5%0.5%0.7%0.5%88.450. 6 % 0.5%2.2%2.6%0.7%(0.2%)9.2%5.1% 3.1%2.0%1.9%2.0% 4.4% 1.2%86.93TOW86.39BOWPROPOSED 1' CHASE 84.6686.4087.90(88.31)OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR.(92.96)(93.11)(93.29)(93.64)(93.68)(93.89)(94.10)PROPOSED FENCE (TYP.)PROPOSED GATE 24' EMERGENCY ACCESS EASEMENT 87.40 87.4087.90 PROPOSED 18' WIDE OVERFLOW WEIR FFE=92.23 EASEMENT EXCLUSION93.7393.7390.929 2 . 2 3 ADA RAMP W/ HANDRAILS PROPOSED ROCK WALL STEPS94.0994.3993.0692.6992.5792.8791.9591.7891.5891.479 1 . 3 6 90.9290.7890.449 0 . 2 4 89.8689.689 0 . 3 7 90.32 88.828 8 . 6 489.4789.42 87.4486.4088.3788.9794.809 4 . 0 0 93.3993.6493.1892.1592.1092.4892.3592.1391.7691.7092.0992.0691.6491.53 9 1 . 7 8 9 1 . 0 9 90.7290.72 9 1 . 0 9 90.0089.4388.6888.5888.2287.6587.4088.45(92.84)(88.75)(93.20)88.68(93.00)(8 8 . 1 6 )89.7389.7390.0592.7394.1093.6492.9291.229 0 . 5 3 88.9491.9091.930.5%92.531.4%1.4%1.4%1.4%1.4%1.8% 2.2% 1.8%91.4891.1592.209 2 . 3 0 1.7%1.1%0.6%3.3%0. 6 % 1.9% 0.1%1.4%1.5%1.5%1.9%1.5%1.9%1.5%1.4%1.4%0.5%1.5%2.1% 0. 5 %94.5994.630.5%1.0%0.2%???(0.4%)(1.1%)(0.3%)(0.4%)2.8%94.652.1%2.5%2.2%1.6%1.6%1.6%2. 4 % 2. 4 % 1 .8% 2. 4 % 2.2%4.4% 2.2% 3 . 9% 2. 8 % 2. 8 % 4.0 % 4.1 % 2.7%1.5%2.1% 2.1%0.1%3.3% 3.5% 2.1%4.0% 4.0% 2.1% 2.1% 2.3% 2.0% 1.5%0.5%2.0%0.5%3.8%2.0%2.2%2.0%0.5%89.023. 5% 2.2%4.2%2.1%6.0%2.4% 3. 0 %2.1%3.8%1.7% 4. 5 % 4.1 %2.7%2.1%0.8% 2.3%94.6994.75(94.41)(94.90)(94.65)93.0392.5194.4994.5394.7095.059 5 . 1 6 1.2%1.6%2.1% 1.7%1.9%1.6% 1.5% 1.5%4.9%4.5%1.5%3.3%2.0%2.0%2.0%0.1% 1.7%2.5%90.3889.2591.379 0 . 0 64.9%5.8%4.8%5.0% 4 .4%3.4% 2.1% 2.6% ???0.9%1.9%5.1% 2.2%2.6%6.1%5.4%5:15:1 5:15:1 4:187.5284.914:1 3.3% 4.0%6.2%2.1% 1.7% 2.0%3.3% 23:1 5:1 14:1 2.0%0.8%89.8891.552.5% 5.0% 7.4% 5.1%6.5%5.0%4:16.3% 0.8%(1.2%)(0.8%) (3. 7 % ) (3 .0% ) (2 .9% )(0.6%)(1.9%) (1.6%) (0.6%)84.82POND 1 100-YR WSEL = 5086.26 INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2-2 SEE SHEET C 312 STORM DRAIN 2-4 SEE SHEET C 312 91.1692.1390.309.9% 9.4% 8.1% NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION, PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CANAL IMPORTATION FLOODPLAIN AND FLOODWAY. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. 7.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET, PER SECTION 10-45 OF CITY CODE. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. 8.STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE SHEET C 402 C 401GRADING PLAN 17 C 401 C 402 C 403 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: UD UD UD UD X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X X X X X X X X X X X X X X X X20' FL-FL 5' SIDEWALK8.5' SIDEWALKDETENTION POND 1 RAIN GARDEN BIOMEDIA AREA PROPOSED 6' CONCRETE PAN PROPOSED UNDERDRAIN PROPOSED 2' CONCRETE PAN EXISTING BUILDINGS (TYP.) EXISTING BUILDINGS (TYP.) EXISTING 2' CONCRETE PAN EXISTING 2' CONCRETE PAN5' SIDEWALKPROPOSED 2' CONCRETE PAN IMPALA CIRCLE±24' FL-FL (TYP.) 3' CONCRETE TRAIL 3' C O N C R E T E T R AI L PROPOSED BOULDER WALL PROPOSED 2' SIDEWALK CHASE 88.2288.5088.6088.27(88.00)(88.42)8 9 . 4 5 PROPOSED 3' CONCRETE PAN W/ FOREBAY1.5%1.5%0.5%0.7%0.5%88.450. 6 % 2.0% 1.2%86.93TOW86.39B OW 0.5%4.1%3.1% PROPOSED OUTLET STRUCTURE (0.2%)(1.0%)85.4085.4686.73 TOW 86.40 BOW (84.48)82.7184.66(84.72)86.4087.90(8 6 . 8 2 )(86.54)(0.3%)EXISTING VERTICAL CURB & GUTTER(88.31)OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/PATRICIA A 2212 WOODFORD CT.OWNER:SIKORSKI, MITCHELL ANDREW2213 W MAGNOLIA CT.OWNER:STEADMAN, VIVIAN LOUISE2212 W MAGNOLIA CT.OWNER: VILLAGES, LTD. 400 IMPALA CIR. EXISTING SIDEWALK CULVERT PROPOSED 6" VERTICAL CURB 24' EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT EXISTING 15' UTILITY EASEMENT REC. NO. 20100011476 EXISTING 20' DRAINAGE & UTILTY EASEMENT REC. NO. 20100011476 EXISTING ACCESS, DRAINAGE, & UTILITY EASEMENT REC. NO. 20100011476 87.40 87.4087.90 PROPOSED 18' WIDE OVERFLOW WEIR EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSIONEASEMENT EXCLUSION87.448 6 . 4 088.3788.9790.008 9 . 4 3 88.6888.5888.2287.6587.4088.45(88.75)(88.16)84.1083.8286.7489.7389.7388.942. 8 % 2. 8 % 2.1% 2.3% 2.0% 1.5%0.5%2.0%3.8%1.7% 4. 5 % 0.1% 1.7%2.5%2.0%89.2591.371.9%5.1%5:15:1 5:15:1 4:14:1 4:14:17:1 4.3%4:1 ( 4 . 0 : 1 ) 4 : 1 86.58TOW 85.58BOW8 5 . 6 085.24BOW85.74TOW83.9288.0087.1487.5284.9184.4986.9685.604:1 6:1(4.5:1)(4.5:1) (2 .9% )84.828 3 . 9 5 83.8683.7883.688 3 . 6 3 83.12 CUT BACK EXISTING PIPE INSTALL SCOURSTOP MAT EXISTING HEADWALL & OVERFLOW WEIR REMOVE EXISTING ORIFICE PLATE REPLACE WITH SOLID PLATE POND 1 100-YR WSEL = 5086.26 POND 1 100-YR WSEL = 5086.26 POND 1 100-YR WSEL = 5086.26(84.61)INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) STORM DRAIN 1 SEE SHEET C 310 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION, PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CANAL IMPORTATION FLOODPLAIN AND FLOODWAY. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. 7.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET, PER SECTION 10-45 OF CITY CODE. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. 8.STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK MATCH LINE - SEE SHEET C 403 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 402GRADING PLAN 18 MATCH LINE - SEE SHEET C 401 C 401 C 402 C 403 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: XXXXXXXXXXXXXXXXXXXXXXXXXXXXIRR IRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR D D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTST975085 (NAVD88)5084 (NAVD88)5083 (NAVD88)5082 (NAVD88)FFE=86.02 WEST MULBERRY STREET 5' SIDEWALK6' SIDEWALK6' CONCRETE TRAILDETENTION POND 2 EXISTING BUILDINGS (TYP.) PROPOSED 3' SIDEWALK CULVERT EXISTING 2' CONCRETE PAN EXISTING 15" STORM DRAIN EXISTING 36" STORM DRAIN EASEMENT EXCLUSION 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT EXISTING HEADWALL & OVERFLOW WEIR(86.82)(86.54)PROPOSED SAWCUT 8 3 . 2 9 8 5 . 3 5 84.5085.35(81.00)85.3585.3585.3584.87(84.62)84. 3 3 TO W 81.33 BOW (0.2%)(4.1%)(1.7%)(0.3%)2.4%(1.0%) 1.3%1.4%(1.4%)(0.9%)PROPOSED SAWCUT TIE IN TO EXISTING 5' SIDEWALK EXISTING VERTICAL CURB & GUTTER EXISTING VERTICAL CURB & GUTTER OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR.OWNER:SIKORSKI, MITCHELL ANDREW2213 W MAGNOLIA CT.OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR HIGH-RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR HIGH-RISK FLOOD FRINGE6' CONCRETE TRAIL8 4 . 5 3 83.635083 (NAVD88)5084 (NAVD88)5085 (NAVD88)X-SEC #2303 - 5085.14' (NAVD88)X-SEC #1983 - 5081.71' (NAVD88)EXISTING VERTICAL CURB & GUTTER PROPOSED LANDSCAPE WALL W/ HANDRAIL 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT (82.33)(84.69)EXISTING 15' UTILITY EASEMENT REC. NO. 20100011476 EXISTING 20' DRAINAGE & UTILTY EASEMENT REC. NO. 20100011476 EXISTING 40' ACCESS, UTILITY, & DRAINAGE EASEMENT REC. NO. 20100011476 PROPOSED 2' SIDEWALK CHASE FOR REFERENCE: REPLACEMENT OF IRRIGATION LATERAL BY CITY OF FORT COLLINS PARKS DEPT. POSSIBLE DURING CONSTRUCTION CONTRACTOR TO COORDINATE WITH CITY OF FORT COLLINS 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT EASEMENT EXCLUSIONEASEMENT EXCLUSION 84.7384.5786.9986.8886.74(80.15)(84.19)2.0% 1.6%1.4%(82.49)82.9183.0284.3184.8784.6884.1383.7983.9483.6584.89TOW84.02B OW 84.4084.391.5%84.855:14:1 15:14:1 8:1 (4.5:1) 7:1 (19 .4 :1 ) (3.9:1) (4.5:1)(4.5:1)7:1(6.1 % ) (1.2%) 85. 0 0 TO W 81.33 BOW 2. 2 %1.6%2.2% PROPOSED SCOURSTOP MAT POND 2 100-YR WSEL = 5082.46 POND 1 100-YR WSEL = 5086.26 0.5% INNER CRITICAL ROOT ZONE (TYP.) OUTER CRITICAL ROOT ZONE (TYP.) STORM DRAIN 1 SEE SHEET C 310 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION, PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CANAL IMPORTATION FLOODPLAIN AND FLOODWAY. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. 7.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET, PER SECTION 10-45 OF CITY CODE. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. 8.STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY LEGEND: PROPOSED GRADE BREAK MATCH LINE - SEE SHEET C 402 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 403GRADING PLAN 19 C 401 C 402 C 403 1.ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2.WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3.ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4.PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5.DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6.NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7.LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8.THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9.NO TREES SHALL BE REMOVED DURING THE SONGBIRD NESTING SEASON (FEBRUARY 1 TO JULY 31) WITHOUT FIRST HAVING A PROFESSIONAL ECOLOGIST OR WILDLIFE BIOLOGIST COMPLETE A NESTING SURVEY TO IDENTIFY ANY ACTIVE NESTS EXISTING ON THE PROJECT SITE. IF ACTIVE NESTS ARE FOUND, THE CITY ENVIRONMENTAL PLANNER WILL DETERMINE WHETHER ADDITIONAL RESTRICTIONS ON TREE REMOVAL AND CONSTRUCTION APPLY. 10.PRIOR TO ANY ONSITE DISTURBANCE PLEASE CONTACT CITY FORESTRY AT CTOMLINSON@FCGOV.COM FOR COORDINATION OF TREE PROTECTION REQUIREMENTS. 11.HYDRO-EXCAVATION OR AIR SPADING SHALL BE DONE AT THE FURTHEST EDGE OF THE DISTURBANCE AREA WITHIN THE CRITICAL ROOT ZONE OF THE TREE DEFINED AS 1 FT. RADIUS FROM THE TRUNK FOR EACH INCH OF DIAMETER MEASURED AT 4.5 FT FROM THE GROUND (DBH). AT THE EDGE OF DISTURBANCE, A 2 FT DEEP AND 6 IN WIDE TRENCH WILL BE MADE TO EXPOSE ANY EXISTING ROOTS USING A PRESSURE SETTING OF LESS THAN 1800 PSI. ALL ROOTS OVER 3 INCHES IN DIAMETER WILL BE INSPECTED BY THE FORESTRY DIVISION PRIOR TO CUTTING OR DISTURBING. ANY ROOT UNDER THIS DIAMETER WILL BE CUT CLEANLY AT THE FURTHEST POSSIBLE POINT AWAY FROM THE TREE WITH A SHARP HAND SAW (NO ROTARY BLADE OR CHAINSAW). THE TREE WILL BE KEPT WELL-WATERED DURING THIS WORK MAKING SURE THE SOIL STAYS MOIST TO A DEPTH OF 12 IN UNTIL PERMANENT IRRIGATION IS INSTALLED. ALL TREE PROTECTION TO STAY IN PLACE UNTIL THIS PROCESS IS COMPLETED. PRIOR TO PERFORMING THIS ACTIVITY PLEASE CONTACT THE FORESTRY DEPARTMENT TO ENSURE THAT ALL HYDRO-EXCAVATION IS APPROVED PRIOR TO START. 12.SEE LANDSCAPE PLANS FOR TREE PROTECTION DETAIL. TREE DIAMETER AT BREAST HEIGHT (IN) AUGER DISTANCE FROM FACE OF TREE (FT) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 TREE PROTECTION NOTES: C 500WATER DETAILS20 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR000WATER MAIN BEDDING SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32001FIRE HYDRANT INSTALLATION 002WATER SERVICE INSTALLATION 003TRAFFIC-RATED CURB STOP INSTALLATION 004STANDARD SETTING FOR 3" AND 4" WATER METER(1 OF 3) 005006STANDARD SETTING FOR 3" AND 4" WATER METER(2 OF 3) STANDARD SETTING FOR 3" AND 4" WATER METER(3 OF 3) C 501SANITARY DETAILS21CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR100SANITARY SEWER LINE TRENCH BEDDING SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32101SANITARY SERVICE CONNECTION TO MAIN 102TRAFFIC-RATED SANITARY CLEANOUT C 502DRAINAGE DETAILS22CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR200SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32201202203206205204STORMWATER BEDDING STORMWATER CROSSING SHALLOW STORM SEWER MANHOLE (FLAT TOP) SIDEWALK CULVERT CONCRETE RUNDOWN WITH FOREBAY STANDARD CONCRETE NOTES CONCRETE TRICKLE PAN 6" CURB AND GUTTERCONCRETE RUNDOWNRAIN GARDEN BASERELIEF NOTCHBIO-MEDIASECTIONS12"7'6"3"CONCRETE RUNDOWN6" CURB AND GUTTER3'7'RELIEF NOTCH2.5"FOREBAYFOREBAYRAIN GARDEN TOPPLAN VIEWPROFILE VIEWINLET SCHEDULEInlet/Basin IDInlet SizeGrate TypeINLET 1-2 (UDRAIN)12" Nyloplast Basin12" DomeBASIN 2-312" Nyloplast Basin12" DomeBASIN 2-512" Nyloplast Basin12" DomeBASIN 2-68" Nyloplast Basin8" DomeBASIN 2-78" Nyloplast Basin8" DomeBASIN 2-88" Nyloplast Basin8" DomeBASIN 2-98" Nyloplast Basin8" DomeBASIN 2-108" Nyloplast Basin8" DomeBASIN 2-2.48" Nyloplast Basin8" DomeBASIN 2-2.1.18" Nyloplast Basin8" DomeBASIN 2-2.2.18" Nyloplast Basin8" DomeBASIN 2-4.112" Nyloplast Basin12" DomeBASIN 2-4.212" Nyloplast Basin12" Dome207INLET SCHEDULE *SEE DRAINAGE REPORT FOR FOREBAY CALCULATIONSBasinIDTotalUndetainedAreaContributingto PondPercentImperviousWQCV (From RainGarden Design)ForebayDepthForebayAreaForebayRelease(2%)(ac)(%)(ft2)1% ofWQCV(ft)(ft2)(cfs)1002.5672%211821.18121.180.439Forebay DimensionsRelease Notch SizingArea(ft2)Width (ft)Length (ft)A =Q/(C*i)Area(in2)Width(in)Depth (in)21.18370.0517.392.53208FOREBAY SIZING CALCULATIONS C 503DRAINAGE DETAILS23SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32304NYLOPLAST DOME GRATE CCAABBSECTION C-CSECTION A-ASECTION B-BWELL SCREENFLOW CONTROL PLATEPLANGENERAL NOTESSECTION D-DDDAAABBREVIATIONSLEGEND302NYLOPLAST STANDARD BASIN REVJ7001-110-144DWG NO.1 OF 1SHEET1:40SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.comDRAIN BASIN WITH STANDARD GRATEQUICK SPEC INSTALLATION DETAILTITLEPROJECT NO./NAMEMATERIALDATEREVISED BY1-23-06DATEEBCDRAWN BY06-12-18NMH(5) ADAPTERANGLESVARIABLE 0° - 360°ACCORDING TOPLANS8" - 36"18" MIN WIDTH GUIDELINE8" MIN THICKNESS GUIDELINE(3) VARIABLE SUMP DEPTHACCORDING TO PLANS(6" MIN. ON 8" - 24", 10" MIN. ON 30"& 12" MIN. ON 36"BASED ON MANUFACTURING REQ.)4" MIN ON 8" - 24"6" MIN ON 30" & 36"MINIMUM PIPE BURIALDEPTH PER PIPEMANUFACTURERRECOMMENDATION(MIN. MANUFACTURINGREQ. SAME AS MIN. SUMP)(3) VARIABLE INVERT HEIGHTSAVAILABLE (ACCORDING TOPLANS/TAKE OFF)THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BEPLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.WATERTIGHT JOINT(CORRUGATED HDPE SHOWN)NYLOPLAST DRAIN BASIN WITH STANDARD GRATE1 - 8" - 30" STANDARD GRATES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.2 - 12" - 30" FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05. 8" & 10" STANDARD GRATES FIT DIRECTLY ONTO DRAIN BASINS WITH THE USE OF A PVC BODY TOP. SEE DRAWING NO. 7001-110-045.3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-065.4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL), N-12 HP, & PVC SEWER (4" - 36").5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.6 - 12" - 30" STANDARD GRATES SHALL MEET H-20 LOAD RATING.7 - 8" & 10" STANDARD GRATES ARE RATED FOR LIGHT DUTY APPLICATIONS ONLY; NO CONCRETE COLLAR NEEDED FOR LIGHT DUTY RATING.(6, 7) TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FORGUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BEDESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS,TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS.SEE DRAWING NO. 7001-110-111 FOR NON TRAFFIC INSTALLATION.(1, 2) INTEGRATED DUCTILE IRONFRAME & GRATE TO MATCH BASIN O.D.THIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.®©2011 NYLOPLAST(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERSAVAILABLE: 4" - 36" FOR CORRUGATED HDPE(ADS N-12/HANCOR DUAL WALL, ADS/HANCORSINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),PVC DWV (EX: SCH 40), PVC C900/C905,CORRUGATED & RIBBED PVCREVD7001-110-211DWG NO.1 OF 1SHEET1:4SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.com15 IN DOME GRATETITLEPROJECT NO./NAMEMATERIALDATEREVISED BYDATEDRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.3-23-11EBC®©2011 NYLOPLASTDUCTILE IRON3-7-06EBCAPPROX. DRAIN AREA = 122.07 SQ INAPPROX. WEIGHT = 26.50 LBSDIMENSIONS ARE FOR REFERENCE ONLYACTUAL DIMENSIONS MAY VARYDIMENSIONS ARE IN INCHESQUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINTLOCKING DEVICE AVAILABLE UPON REQUEST1599CGDD DONOTPOLLUTER A INSTOWATERWAYSAADUCTILEI RON N Y L O P L A S TSECTION A-A6.00Ø16.13REVE7001-110-397DWG NO.1 OF 1SHEET1:40SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.comDRAIN BASIN WITH DOME GRATEQUICK SPEC INSTALLATION DETAILTITLEPROJECT NO./NAMEMATERIALDATEREVISED BY03-25-10DATEEBCDRAWN BY06-12-18NMH8" - 36"(3) VARIABLE SUMP DEPTHACCORDING TO PLANS(6" MIN. ON 8" - 24", 10" MIN. ON 30"& 12" MIN. ON 36"BASED ON MANUFACTURING REQ.)4" MIN ON 8" - 24"6" MIN ON 30" & 36"MINIMUM PIPE BURIALDEPTH PER PIPEMANUFACTURERRECOMMENDATION(MIN. MANUFACTURINGREQ. SAME AS MIN. SUMP)(3) VARIABLE INVERT HEIGHTSAVAILABLE (ACCORDING TOPLANS/TAKE OFF)THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BEPLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.WATERTIGHT JOINT(CORRUGATED HDPE SHOWN)NYLOPLAST DRAIN BASIN WITH DOME GRATE1 - 8" - 30" DOME GRATES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.2 - 8" & 10" DOME GRATES FIT ONTO THE DRAIN BASINS WITH THE USE OF A PVC BODY TOP. SEE DRAWING NO. 7001-110-045.3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-065.4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS N-12/HANCOR DUAL WALL), N-12 HP, & PVC SEWER (4" - 36").5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012.6 - 8" - 30" DOME GRATES HAVE NO LOAD RATING.(1, 2) INTEGRATED DUCTILE IRONGRATE TO MATCH BASIN O.D.THIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.®©2013 NYLOPLAST(4) VARIOUS TYPES OF INLET & OUTLET ADAPTERSAVAILABLE: 4" - 36" FOR CORRUGATED HDPE(ADS N-12/HANCOR DUAL WALL, ADS/HANCORSINGLE WALL), N-12 HP, PVC SEWER (EX: SDR 35),PVC DWV (EX: SCH 40), PVC C900/C905,CORRUGATED & RIBBED PVC(5) ADAPTER ANGLES VARIABLE0° - 360° ACCORDING TO PLANS300WATER QUALITY OUTLET STRUCTURE 303NYLOPLAST DRAIN BASIN WITH DOME GRATE 301RAIN GARDEN BIORETENTION C 504DRAINAGE DETAILS24CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR400NYLOPLAST DRAIN BASIN WITH REDUCER SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32REVE7001-110-111DWG NO.1 OF 1SHEET1:25SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.comDRAIN BASIN & INLINE DRAIN NON TRAFFIC INSTALLATIONTITLEPROJECT NO./NAMEMATERIALDATEREVISED BY9-30-99DATECJADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.03-11-16NMHDRAIN BASININLINE DRAINTHE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BEPLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.NON TRAFFIC INSTALLATIONTOP SOILGRATE/COVERTOP SOILGRATE/COVER®©2011 NYLOPLAST4" MIN ON 8" - 24"6" MIN ON 30"THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHERGRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS I,CLASS II, OR CLASS III MATERIAL AS DEFINED IN ASTM D2321.BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BEPLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321.REVC7001-110-104DWG NO.1 OF 1SHEET1:25SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.comDRAIN BASIN WITH REDUCER OPTIONSTITLEPROJECT NO./NAMEMATERIALDATEREV'D BY2-6-03DATECJADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.1-6-09EBCBAC MINCONE STYLE REDUCERNOTE: DIMENSIONS ARE FOR REFERENCE ONLYACTUAL DIMENSIONS MAY VARY®©2007 NYLOPLASTBAD MINCAP STYLE REDUCER6" MIN ON 8" - 24"10" MIN ON 30"6" MIN ON 8" - 24"10" MIN ON 30"REVB7001-110-021DWG NO.1 OF 1SHEET1:6SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.com12 IN DROP INTITLEPROJECT NO./NAMEMATERIALDATEAPPD BY3-5-00DATEAWADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.3-5-00CJA20 X .50.501.50Ø 11.641201DIAPPROX. DRAIN AREA = 39.75 SQ INAPPROX. WEIGHT WITH FRAME = 20.15 LBSALL DIMENSIONS IN INCHES UNLESS NOTED OTHERWISEGRATE HAS LIGHT DUTY RATINGQUALITY: MATERIALS SHALL CONFORM TO ASTM A536 GRADE 70-50-05PAINT: CASTINGS ARE FURNISHED WITH A BLACK PAINTSIZE OF OPENING MEETS REQUIREMENTS OF AMERICAN DISABILITYACT AS STATED IN FEDERAL REGISTER PART III, DEPARTMENT OFJUSTICE, 28 CFR PART 36. NONDISCRIMINATION ON THE BASIS OFDISABILITY BY PUBLIC ACCOMMODATIONS AND IN COMMERCIALFACILITIES, FINAL BY RULE.NDUCTILEIRONYLOPLASTØ13.73REVC7001-110-017DWG NO.1 OF 1SHEET1:8SCALEDWG SIZEA3130 VERONA AVEBUFORD, GA 30518PHN (770) 932-2443FAX (770) 932-2490www.nyloplast-us.com6 IN - 24 IN DROP IN INSTALLATIONTITLEPROJECT NO./NAMEMATERIALDATEAPPD BY5-4-00DATEAWADRAWN BYTHIS PRINT DISCLOSES SUBJECT MATTER IN WHICHNYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPTOR POSSESSION OF THIS PRINT DOES NOT CONFER,TRANSFER, OR LICENSE THE USE OF THE DESIGN ORTECHNICAL INFORMATION SHOWN HEREINREPRODUCTION OF THIS PRINT OR ANY INFORMATIONCONTAINED HEREIN, OR MANUFACTURE OF ANYARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERSIS FORBIDDEN, EXCEPT BY SPECIFIC WRITTENPERMISSION FROM NYLOPLAST.5-4-00CJA0601DI0801DI1001DI1201DI1501DI1801DI2401DIBACKFILL MATERIAL BELOW AND TOSIDES OF STRUCTURE SHALL BE NATIVE SOILAND BE PLACED UNIFORMLY IN 12" LIFTS ANDCOMPACTED TO A MIN OF 90%NYLOPLAST DROP IN GRATES FIT INSIDEADS N-12, HANCOR DUAL WALL, SDR 35SEWER, & IPS SCH 40 DWV PIPE401NYLOPLAST NON-TRAFFIC RATED DRAIN BASIN 402NYLOPLAST 12" DROP BASIN SLOTTED LID 403NYLOPLAST 6"-24" DROP BASIN INSTALLATION CITY OF FORT COLLINSBIORETENTION SAND MEDIA SPECIFICATIONPART 1 - GENERALA. Bioretention Sand Media (BSM) shall be uniformly mixed, uncompacted, free of stones,stumps, roots, or other similar objects larger than two inches. No other materials orsubstances shall be mixed or dumped within the bioretention area that may be harmful to plantgrowth or prove a hindrance to the facility’s function and maintenance.B. BSM shall be free of plant or seed material of non-native, invasive species, or weeds.C. Fully mixed BSM shall be tested prior to installation and meet the following criteria:1. P-Index of less than 302. pH of 5.5-6.5. Should pH fall outside of the acceptable range, it may be modified withlime (to raise) or iron sulfate plus sulfur (to lower). The lime or iron sulfate must be mixeduniformly into the BSM prior to use in the bioretention facility.3. Cation Exchange Capacity (CEC) greater than 104. Phosphorous (Phosphate, P2O5) not to exceed 69 ppm5. BSM that fails to meet the minimum requirements shall be replaced at the Contractor’sexpense.D. BSM shall be delivered fully mixed in a drum mixer. Onsite mixing of piles will not be allowed.Mixing of the BSM to a homogeneous consistency shall be done to the satisfaction of theOwner.PART 2 - SOIL MATERIALSA. Sand1. BSM shall consist of 60% sand by volume meeting ASTM C-33.B. Shredded Cedar Mulch1. BSM shall consist of 5% shredded cedar mulch by volume.2. Shredded mulch shall be loosely packed, approximate bulk density of 50-100 lbs/CY.C. Topsoil1. BSM shall consist of 30% topsoil by volume.2. Topsoil shall be classified as sandy loam, loamy sand, or loam per USDA textural trianglewith less than 5% clay material.3. Onsite, native material shall not be used as topsoil.4. Textural analysis shall be performed on topsoil, preferably at its source, prior to includingtopsoil in the mix. Topsoil shall be free of subsoil, debris, weeds, foreign matter, and anyother material deleterious to plant health.5. Topsoil shall have a pH range of 5.5 to 7.5 and moisture content between 25-55%.6. Contractor shall certify that topsoil meets these specifications.D. Leaf Compost1. BSM shall consist of 5% leaf compost by volume.2. Leaf compost shall consist of Class 1 organic leaf compost consisting of aged leaf mulchresulting from biological degradation and transformation of plant-derived materials undercontrolled conditions designed to promote aerobic decomposition.December 2017BIORETENTION SAND MEDIA SPECIFICATION 23. The material shall be well composted, free of viable weed seeds and contain material of agenerally humus nature capable of sustaining growth of vegetation, with no materialstoxic to plant growth.4. Compost shall be provided by a local US Composting Council Seal of Testing Assurance(STA) member. A copy of the provider’s most recent independent STA test report shallbe submitted to and approved by the Owner prior to delivery of BSM to the project site.5. Compost material shall also meet the following criteria:a. 100 percent of the material shall pass through a 1/2 inch screenb. PH of the material shall be between 6.0 and 8.4c. Moisture content shall be between 35 and 50 percentd. Maturity greater than 80 percent (maturity indicator expressed as percentage ofgermination/vigor, 80+/80+)e. Maturity indicator expressed as Carbon to Nitrogen ration < 12f. Maturity indicator expressed as AmmoniaN/NitrateN Ratio <4g. Minimum organic matter shall be 40 percent dry weight basish. Soluble salt content shall be no greater than 5500 parts per million or 0-5mmhos/cmi. Phosphorus content shall be no greater than 325 parts per millionj. Heavy metals (trace) shall not exceed 0.5 parts per millionk. Chemical contaminants: meet or exceed US EPA Class A standard, 40 CFR503.13, Tables 1 & 3 levelsl. Pathogens: meet or exceed US EPA Class A standard, 40 CFR 503.32(a) levelsPART 3 - EXECUTIONA. General1. Refer to project specifications for excavation requirements.B. Placement Method1. BSM material shall be spread evenly in horizontal layers.2. Thickness of loose material in each layer shall not exceed 9-inches.3. Compaction of BSM material is not required.401BIORETENTION SAND MEDIASPECIFICATIONS C 505SITE DETAILS25CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRSheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32500VERTICAL CURB & GUTTER 501HIGH VOLUME DRIVEWAY APPROACHW/ DETACHED SIDEWALK502STREET INTERSECTION CROSSPAN 503VERTICAL CURB & GUTTER 504TYPICAL SIGN POST 505"NO PARKING ANY TIME" SIGN 506ADA PARKING REQUIREMENTS 507DECORATIVE RAISED CONCRETE CROSSWALK C 506SITE DETAILS26CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRSheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32600BICYCLE RACK FOUNDATION 601STANDARD BICYCLE RACK 602PRIVATELY MAINTAINED STREET SIGNS EEEE CTVCTVCTVE E E6" W6" W6" W6" W 6" W 6" W 6" W W6" W6" W6" WEE EEE E E EE E EGGGG GG GGGGGGG G G GGG G G G GCTVCTV CTVEEEE E CTVCTVCTVCTVCTVCTVCTVE 6" W6" W6" WGGGGGGG G G G G CTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV EEEEEE EE EE EEE E EEEEEE E EEEEE EXXXX X XG GG XXVAULTELECELECVAULTELECCTCCTSSHYDHYDVAULTELECVAULTELECCABLEVAULTELECSSVAULTELECVAULTCABLEVAULTCABLEHYDCCTCCCABLECTCTCCCTCVAULTELECHY D VAULTF.O.XX XXXXXXXXXXXXXXXXXXXXXXXXXWWXXXXXXSWWGGGGGGGGGGGEEEEEEEEEEGGGGGGGGGGGGGGGX X X X EEEEEEEEEEEE8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS WWWWWW WWWWWWWWWWWWWW WWWWWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWW WWWWWWWWWW WW WW WWWWWWIRR IRR IRRIRRIRRIRR IRR IRR WCSSSFODSSDS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS8" SS8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SSST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST16" W16" W16" W16" W16" W 16" W 16" W 16" W16" W16" W16" W16" WXXXXXXXXX XCTVCTVCTV G G GFOFOFOFOTTTTT GGGFOFOFOFOEE8Ŕ W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W ELECWSSCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRNORTH( IN FEET )1 inch = ft.Feet0505050100150PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYBENCHMARK/BASIS OF BEARING:SILT FENCEROCK SOCK1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 22, 2023 BYNORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.5.TRACKING OF MUD IS NOT PERMITTED ON CITY STREETS, IN THE EVENT OFCONSTRUCTION VEHICLES TRACKING MUD, THE CONTRACTOR SHALL BERESPONSIBLE FOR SWEEPING AND CLEANING THE TRACKED AREAS WITHIN 24HOURS.6.THE RAIN GARDEN SHALL BE CONSTRUCTED AS PART OF THE FINAL PHASE TOMINIMIZE POTENTIAL FOR SEDIMENTATION.7.FINAL SITE STABILIZATION SHALL BE COMPLETED IN ACCORDANCE WITH THISDEVELOPMENT'S APPROVED LANDSCAPE PLAN.GENERAL NOTES:WATTLE DIKECONCRETE WASH AREALEGEND:SFC 600EROSION CONTROL PLAN PRE-CONSTRUCTION27 BENCHMARK 25-97 AT THE SOUTHWEST CORNER OF MULBERRY ST. AND TAFTHILL RD., ON A CONCRETE TRAFFIC SIGNAL BASE.ELEVATION = 5071.25BENCHMARK 24-97 ON A CONCRETE HEADWALL PIPE IN ROGERS PARK. SOUTHOF THE PARKING AREA OF ROGERS PARK (150 FEET SOUTH OF LARGE BARN)2500 BLOCK OF MULBERRY ST.ELEVATION = 5102.71BASIS OF BEARINGBASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHEAST QUARTER OFSECTION 11, TOWNSHIP 5 NORTH, RANGE 67 WEST AS BEARING NORTH 89° 37'03" WEST (ASSUMED BEARING)HORIZONTAL DATUMCOORDINATE SYSTEM IS A NORTHERN ENGINEERING LOCAL COORDINATESYSTEM BASED ON MODIFIED STATE PLANE COORDINATES SCALED AT1.00026470 (0.99973537) ABOUT (0,0). LINEAL MEASURE IS BASED ON THE U.S.SURVEY FOOT.SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32KEYMAPSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF100' (TYP.)OUTLET PROTECTIONINLET PROTECTIONVEHICLE TRACKING CONTROL PADSCOURSTOP MATSFSFSFSFSFSFSFSFSFSFSFSFSFS F SF 6Ŕ W6" W6" W6" W 6" W 6" W 6" W 6" W6" W6" WE E E E EE E E GGGGGGG G G E E CTVCTVCTVCTVCTVCTVCTVE 6" W6" W6" WGGGGGGG G G G G CTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV EEEEEE EE EE EEE E EEEEEE E EEEEE EG XXVAULTELECVAULTELECCABLEVAULTELECSSVAULTELECVAULTCABLEVAULTCABLEHYDCCTCCCABLECTCTCCCTCVAULTELECHY D VAULTF.O.XXXXXXXXXXXXXXXXXWWXXXXXXSWWGGGGGGGGGGGGX X X X EEEEEEEEEEEE8" SS8" SS8" SSS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS IRR IRR IRRIRRIRRIRR IRR IRR WCSSSFODSSDS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS8" SS8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SSST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST16Ŕ W16" W16" W16" W16" W 16" W 16" W 16" W16" W16" W16" W16" WXXXXXXXXX XCTVCTVCTV G G GFOFOFOFOTTTTT GGGFOFOFOFOEE8Ŕ W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W ELECXXXXXXUDCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRNORTH( IN FEET )1 inch = ft.Feet0505050100150PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYBENCHMARK/BASIS OF BEARING:SILT FENCEROCK SOCKGENERAL NOTES:WATTLE DIKECONCRETE WASH AREALEGEND:SFC 601EROSION CONTROL PLAN DURING CONSTRUCTION 28BENCHMARK 25-97 AT THE SOUTHWEST CORNER OF MULBERRY ST. AND TAFTHILL RD., ON A CONCRETE TRAFFIC SIGNAL BASE.ELEVATION = 5071.25BENCHMARK 24-97 ON A CONCRETE HEADWALL PIPE IN ROGERS PARK. SOUTHOF THE PARKING AREA OF ROGERS PARK (150 FEET SOUTH OF LARGE BARN)2500 BLOCK OF MULBERRY ST.ELEVATION = 5102.71BASIS OF BEARINGBASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHEAST QUARTER OFSECTION 11, TOWNSHIP 5 NORTH, RANGE 67 WEST AS BEARING NORTH 89° 37'03" WEST (ASSUMED BEARING)HORIZONTAL DATUMCOORDINATE SYSTEM IS A NORTHERN ENGINEERING LOCAL COORDINATESYSTEM BASED ON MODIFIED STATE PLANE COORDINATES SCALED AT1.00026470 (0.99973537) ABOUT (0,0). LINEAL MEASURE IS BASED ON THE U.S.SURVEY FOOT.SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32KEYMAP100' (TYP.)OUTLET PROTECTIONINLET PROTECTIONVEHICLE TRACKING CONTROL PADSCOURSTOP MATRAIN GARDEN 1SFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF 1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 22, 2023 BYNORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.5.TRACKING OF MUD IS NOT PERMITTED ON CITY STREETS, IN THE EVENT OFCONSTRUCTION VEHICLES TRACKING MUD, THE CONTRACTOR SHALL BERESPONSIBLE FOR SWEEPING AND CLEANING THE TRACKED AREAS WITHIN 24HOURS.6.THE RAIN GARDEN SHALL BE CONSTRUCTED AS PART OF THE FINAL PHASE TOMINIMIZE POTENTIAL FOR SEDIMENTATION.7.FINAL SITE STABILIZATION SHALL BE COMPLETED IN ACCORDANCE WITH THISDEVELOPMENT'S APPROVED LANDSCAPE PLAN. 6Ŕ W6" W6" W6" W 6" W 6" W 6" W 6" W6" W6" WE E E E EE E E GGGGGGG G G E E CTVCTVCTVCTVCTVCTVCTVE 6" W6" W6" WGGGGGGG G G G G CTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV EEEEEE EE EE EEE E EEEEEE E EEEEE EG XXVAULTELECVAULTELECCABLEVAULTELECSSVAULTELECVAULTCABLEVAULTCABLEHYDCCTCCCABLECTCTCCCTCVAULTELECHY D VAULTF.O.XXXXXXXXXXXXXXXXXWWXXXXXXSWWGGGGGGGGGGGGX X X X EEEEEEEEEEEE8" SS8" SS8" SSS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS IRR IRR IRRIRRIRRIRR IRR IRR WCSSSFODSSDS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS8" SS8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SSST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST16Ŕ W16" W16" W16" W16" W 16" W 16" W 16" W16" W16" W16" W16" WXXXXXXXXX XCTVCTVCTV G G GFOFOFOFOTTTTT GGGFOFOFOFOEE8Ŕ W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W ELECXXXXXXUDCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRNORTH( IN FEET )1 inch = ft.Feet0505050100150PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYBENCHMARK/BASIS OF BEARING:SILT FENCEROCK SOCKSCOURSTOP MATGENERAL NOTES:WATTLE DIKECONCRETE WASH AREALEGEND:SFC 602EROSION CONTROL PLAN POST-CONSTRUCTION29 BENCHMARK 25-97 AT THE SOUTHWEST CORNER OF MULBERRY ST. AND TAFTHILL RD., ON A CONCRETE TRAFFIC SIGNAL BASE.ELEVATION = 5071.25BENCHMARK 24-97 ON A CONCRETE HEADWALL PIPE IN ROGERS PARK. SOUTHOF THE PARKING AREA OF ROGERS PARK (150 FEET SOUTH OF LARGE BARN)2500 BLOCK OF MULBERRY ST.ELEVATION = 5102.71BASIS OF BEARINGBASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHEAST QUARTER OFSECTION 11, TOWNSHIP 5 NORTH, RANGE 67 WEST AS BEARING NORTH 89° 37'03" WEST (ASSUMED BEARING)HORIZONTAL DATUMCOORDINATE SYSTEM IS A NORTHERN ENGINEERING LOCAL COORDINATESYSTEM BASED ON MODIFIED STATE PLANE COORDINATES SCALED AT1.00026470 (0.99973537) ABOUT (0,0). LINEAL MEASURE IS BASED ON THE U.S.SURVEY FOOT.SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32KEYMAPOUTLET PROTECTIONINLET PROTECTIONVEHICLE TRACKING CONTROL PADRAIN GARDEN 11.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 22, 2023 BYNORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.5.TRACKING OF MUD IS NOT PERMITTED ON CITY STREETS, IN THE EVENT OFCONSTRUCTION VEHICLES TRACKING MUD, THE CONTRACTOR SHALL BERESPONSIBLE FOR SWEEPING AND CLEANING THE TRACKED AREAS WITHIN 24HOURS.6.THE RAIN GARDEN SHALL BE CONSTRUCTED AS PART OF THE FINAL PHASE TOMINIMIZE POTENTIAL FOR SEDIMENTATION.7.FINAL SITE STABILIZATION SHALL BE COMPLETED IN ACCORDANCE WITH THISDEVELOPMENT'S APPROVED LANDSCAPE PLAN. SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32C 603EROSION CONTROL DETAILS30CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallR001SILT FENCE SFSFCWA002CONCRETE WASHOUT VTC003VEHICLE TRACKING CONTROL PAD 005CURB INLET PROTECTION004WATTLE DIKE WD006DROP INLET PROTECTIONIPROCK SOCK SECTIONROCK SOCK PLANROCK SOCK JOINTINGGRADATION TABLESIEVE SIZEMASS PERCENTPASSING SQUAREMESH SIEVESNO. 42"1001-1/2"90-1001"20-553/4"0-153/8"0-5MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FORCONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE,ALL SIDESRSAAPLAN VIEWSECTION A-A2:1OPWQCV008OUTLET STRUCTURE PROTECTION 007ROCK SOCK IP XXX XXXXXX XX X XXX XXX X X X X X X XXXXXXXXXXXXXXXXXXXXXWW WW WWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WW WWWWWWWWWWWWWWWWWWWW WW WWWWWWWWWW WWWWWWWWWW WWWWIRRIRRIRR IRR IRR IRR IRR IRR D D D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTXXXXXXXXXXTTTTT45088 (NAVD88)28975087 (NAVD88)5086 (NAVD88)5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)5082 (NAVD88)5081 (NAVD88)5080 (NAVD88)POND 1 POND 2 100 101 OS1 IMPALA CIRCLE SOUTH IMPALA DRIVEWEST MULBERRY STREET IMPALA CIRCLE OLIVE STREET EXISTING 15" STORM DRAIN EXISTING 36" STORM DRAIN EXISTING 2' CONCRETE PAN EXISTING HEADWALL & OVERFLOW WEIR EXISTING HEADWALL & OVERFLOW WEIR CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR HIGH-RISK FLOOD FRINGE CITY OF FORT COLLINS 100-YR HIGH-RISK FLOOD FRINGE OS1 200 OS2 100 OS4 102 101 OS3 X-SEC #2303 - 5085.14' (NAVD88)X-SEC #1983 - 5081.71' (NAVD88)C 610DRAINAGE EXHIBITHISTORIC31 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 22, 2023 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. 2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION, PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CANAL IMPORTATION FLOODPLAIN AND FLOODWAY. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE. 3.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET, PER SECTION 10-45 OF CITY CODE. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. 4.STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. A LEGEND: FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 32 XXXXXXXXXXXXXXXXXXXXXXXXXX X X X DDDSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTXXXXXXXXX X 42 8 9 7 XXXXXXOS1102200OS2101OS3100101OS1102UD200OS3OS4OS2EXISTING 10'EASEMENTIMPALA CIRCLESOUTH IMPALA DRIVEWEST MULBERRY STREETIMPALA CIRCLEOLIVE STREETDETENTIONPOND 2RAINGARDEN 1DETENTIONPOND 1EXISTING 36"STORM DRAINEXISTING 15"STORM DRAINPROPOSED 6'CONCRETE PANPROPOSED 2'CONCRETE PANPROPOSED OUTLETSTRUCTUREEXISTING 2'CONCRETE PANPROPOSED 2'SIDEWALK CHASEPROPOSEDSCOURSTOPRUNDOWNPROPOSEDSTORM DRAINPROPOSED 3'CONCRETE RUNDOWNAND FOREBAYPROPOSEDSTORM DRAINPROPOSED STORMDRAINOS4PROPOSED 2'CONCRETE PAN100EXISTINGHEADWALLEXISTINGHEADWALLOS5OS55088 (NAVD88)5087 (NAVD88)5086 (NAVD88) 5085 (NAVD88) 5084 (NAVD88) 5083 (NAVD88) 5082 (NAVD88) 5081 (NAVD88) 5080 (NAVD88)CITY OF FORT COLLINS100-YR FLOODWAYCITY OF FORT COLLINS100-YR HIGH-RISKFLOOD FRINGECITY OF FORT COLLINS100-YR HIGH-RISKFLOOD FRINGEX-SEC #2303 - 5085.14' (NAVD88) X-SEC #1983 - 5081.71' (NAVD88)PROPOSEDOVERFLOWWEIRPOND 2 100-YR WSEL = 5082.46POND 1 100-YR WSEL = 5086.26C 611DRAINAGE EXHIBIT DEVELOPED32CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRNORTH( IN FEET )1 inch = ft.Feet0505050100150PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYPROPOSED INLETADESIGN POINTFLOW ARROWDRAINAGE BASIN LABELDRAINAGE BASIN BOUNDARYPROPOSED SWALE SECTION11NOTES:1.REFER TO THE FINAL DRAINAGE REPORT, DATED FEBRUARY 22, 2023 BYNORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OFFORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TOCOMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES,GRADING, FILL, DETENTION, PONDS, BIKE PATHS, PARKING LOTS, UTILITIES,LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE CANALIMPORTATION FLOODPLAIN AND FLOODWAY. ALL ACTIVITIES WITHIN THEFLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORTCOLLINS MUNICIPAL CODE.3.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS,DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAYUNLESS NO-RISE CONDITIONS ARE MET, PER SECTION 10-45 OF CITY CODE. ANYCONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDEA NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED INCOLORADO.4.STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOTALLOWED IN THE FLOODWAY.ALEGEND:FOR DRAINAGE REVIEW ONLYNOT FOR CONSTRUCTIONSheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 32Rational Flow Summary | Developed Basin Flow RatesBASINIDTOTAL AREA(acres)Tc2(min)Tc100(min)C2C100Q2(cfs)Q100(cfs)1002.565.05.00.730.795.3420.161010.845.05.00.310.390.743.231021.955.05.00.630.793.5015.262001.995.05.00.430.542.4410.65OS10.205.05.00.790.990.461.99OS24.9313.913.90.250.312.4010.50OS30.0410.210.20.250.310.020.09OS40.295.05.00.650.810.532.32OS50.015.05.00.951.000.040.13