HomeMy WebLinkAboutIMPALA REDEVELOPMENT - FDP230001 - SUBMITTAL DOCUMENTS - ROUND 3 - PHOTOMETRIC PLAN2018 INTERNATIONAL ENERGY
CONSERVATION CODE
1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE 2018 IECC.
2. AS REQUIRED BY SECTION C405 ALL LIGHTING SYSTEMS SHALL BE
COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. THE
COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE
MANUFACTURER'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED THIRD
PARTY AGENCY.
3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT OCCUPANTS
AND CONTROL THE LIGHTS INDICATED ON THE PLANS.
4. AS REQUIRED BY SECTION C408.3.2 THE COMMISSIONING DOCUMENTS
DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN 90
DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY.
ELECTRICAL SYMBOL SCHEDULE
L
SURFACE ADJUSTABLE DOWNLIGHT
SURFACE DOWNLIGHT
RECESSED ADJUSTABLE DOWNLIGHT
RECESSED DOWNLIGHT
RECESSED TROFFER
SURFACE TROFFER
WALL MOUNT
PENDANT MOUNT LINEAR
PENDANT MOUNT
SURFACE LINEAR
SURFACE STRIP
CONCEALED LED STRIP / TAPE
ROUND BOLLARD
EXIT SIGN WALL MOUNT - ARROW AND FACES AS SHOWN ON PLANS
EXIT SIGN CEILING MOUNT - ARROW AND FACES AS SHOWN ON PLANS
EMERGENCY BATTERY UNIT
TRACK
FLOOD / ACCENT
EXTERIOR POLE MOUNT
WALL MOUNTED EXIT SIGN LOW LEVEL
SQUARE BOLLARD
CEILING MOUNTED FAN WITH CLEARANCE
LUMINAIRE SYMBOLS
LIGHTING CONTROL SYMBOLS
a,b - SWITCH LEG(S)
BLANK - SINGLE POLE SWITCH
3 - 3 WAY SWITCH
4 - 4 WAY SWITCH
D - DIMMER
D3 - DIMMER, 3 WAY
DOS - DIMMER OCCUPANCY SENSOR SWITCH
OS - OCCUPANCY SENSOR SWITCH
T - TIMER SWITCH
a
SOS
# - DEVICE NUMBER
a,b - SWITCH LEG(S)
z# - CONTROL ZONE(S)
CS - CONTROL STATION
OS - OCCUPANCY SENSOR
VS - VACANCY SENSOR
TS - TOUCH SCREEN
PC - PHOTOCELL
WITH STEM - WALL MOUNT
WITHOUT STEM - CEILING MOUNT
OS1
a
NOTES:
A. SWITCH LEG DESIGNATION USED FOR ROOM(S) WITH STANDALONE LIGHTING
CONTROLS.
B. CONTROL ZONE DESIGNATION USED FOR LIGHTING CONTROL ZONES AS PART OF
PROGRAMMABLE LIGHTING CONTROL PANEL.
ABBREVIATIONS
RCP REFLECTED CEILING PLAN
LLF LIGHT LOSS FACTOR
LED LIGHT EMITTING DIODE
CRI COLOR RENDERING INDEX
CCT CORRELATED COLOR TEMPERATURE
CL CONNECTED LOAD
DL DESIGN LOAD
DF DEMAND FACTOR
OC OVER CURRENT
VD VOLTAGE DROP
FSD FIRE SMOKE DAMPER
P POLE
N NEUTRAL
EMS EMERGENCY MANAGEMENT SYSTEM
VFD VARIABLE FREQUENCY DRIVE
(N) NEW
(F) FUTURE
(R) RELOCATE EXISTING
(D) DEMOLISH EXISTING
(E)EXISTING TO REMAIN
FLC FULL LOAD CURRENT (NEC)
FLA FULL LOAD AMPS (NAME PLATE)
MOCP MAXIMUM OVER CURRENT PROTECTION
MCA
W WATT
VA VOLT AMPERESV
VOLT
TEL TELEPHONE
TC TERMINAL CABINET
TB, TTB TERMINAL BACKBOARD
SWGR SWITCH GEAR
SWBD SWITCHBOARD
SPST SINGLE POLE, SINGLE THROW
SPDT SINGLE POLE, DOUBLE THROW
RSC RIGID STEEL CONDUIT
PWR POWER
PVC POLYVINYL CHLORIDE CONDUIT
PNL PANEL
∅, PH PHASE
PB PULL BOX
OFCI OWNER FURNISHED
CONTRACTOR INSTALLED
NTS NOT TO SCALE
NO NORMALLY OPEN
NL NIGHT LIGHT
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S ASSOCIATION
NC NORMALLY CLOSED
MLO MAIN LUGS ONLY
MCB MAIN CIRCUIT BREAKER
LRC LIGHTING RELAY CABINET
HPF HIGH POWER FACTOR
HP HORSEPOWER
HOA HAND - OFF - AUTO
IG ISOLATED GROUND.
GENERATORGEN
G, GND GROUND
GFCI GROUND FAULT
CIRCUIT INTERRUPTING
FVR FULL-VOLTAGE, REVERSING
FVNR FULL-VOLTAGE, NON-REVERSING
FA FIRE ALARM
ELECTRO METALLIC TUBINGEMT
E, EM EMERGENCY
ELEV ELEVATOR
ELEC ELECTRICAL
EC EMPTY CONDUIT
DIST DISTRIBUTION
DPST DOUBLE POLE SINGLE THROW
DPDT DOUBLE POLE, DOUBLE THROW
DC DIRECT CURRENT
CLG CEILING
CKT CIRCUIT
CFOI CONTRACTOR FURNISHED OWNER
INSTALLED
C CONDUIT
AV AUDIO VISUAL
AWG AMERICAN WIRE GAUGE
AT TRIP RATING IN AMPERES
AS SWITCH RATING IN AMPERES
AF FRAME RATING IN AMPERES
ATS AUTOMATIC TRANSFER SWITCH
AFG ABOVE FINISHED GRADE
AFF ABOVE FINISHED FLOOR
AIC AMPERE INTERRUPTING CAPACITY
ACT ABOVE COUNTER TOP
AC ALTERNATING CURRENT
A, AMP AMPERE
W WIRE
XFMR TRANSFORMER
V
MINIMUN CIRCUIT AMPS
ELECTRICAL GENERAL NOTES
A. WHERE GROUNDED CONDUCTORS OF DIFFERENT SYSTEMS ARE INSTALLED IN THE SAME RACEWAY,
CABLE, BOX, AUXILIARY GUTTER, OR OTHER TYPE OF ENCLOSURE, EACH GROUNDED CONDUCTOR
SHALL BE IDENTIFIED BY SYSTEM PER NEC ARTICLE 200.6 (D). MEANS OF IDENTIFICATION SHALL BE
PERMANENTLY POSTED AT EACH BRANCH CIRCUIT PANELBOARD.
B. PER NEC ART 210.5 (C), UNGROUNDED CONDUCTORS OF MORE THAN ONE NOMINAL VOLTAGE
SYSTEM SHALL BE IDENTIFIED BY SYSTEM. PROVIDE MEANS OF IDENTIFICATION AS REQUIRED PER
THIS ARTICLE.
C. PER NEC ART 215.12, FEEDER IDENTIFICATION IS REQUIRED WHEN MORE THAN ONE NOMINAL
VOLTAGE SYSTEM EXISTS. PROVIDE MEANS OF IDENTIFICATION AS REQUIRED PER THIS ARTICLE.
D. VERIFY FINAL PLACEMENT AND CONNECTION REQUIREMENTS PRIOR TO ROUGHING IN EQUIPMENT
UTILITIES.
E. FINAL ACCEPTANCE OF WORK IN PLACE SHALL BE SUBJECT TO APPROVAL BY OWNER'S
REPRESENTATIVE. INSTALLATION APPROVAL SHALL BE BASED ON APPROVED SUBMITTAL, SHOP
DRAWINGS AND LOCAL INSPECTIONS.
F. SUBMIT RED-LINE RECORD DRAWINGS WITHIN TWO (2) WORK WEEKS OF DATE OF NOTIFICATION OF
FINAL APPROVAL.
G. ALL WORK SHOWN ON DRAWINGS IS IN PART SCHEMATIC, INTENDED TO CONVEY SCOPE OF WORK
AND GENERAL LAYOUT. VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS REQUIRED.
ELECTRICAL DRAWINGS ARE LARGELY DIAGRAMMATIC AND, THEREFORE, REPRESENT
INSTALLATION INTENT AND GUIDELINES; IT IS THE CONTRACTOR'S RESPONSIBILITY TO COVER ALL
CONDITIONS ON THEIR PREPARED SHOP DRAWINGS.
H. PROVIDE UP-TO-DATE, ACCURATE, AND LEGIBLE CIRCUIT DIRECTORY WHICH APPLIES TO
PANELBOARDS AND SWITCHBOARDS AS REQUIRED BY NEC ART. 408.4 DIRECTORY SHALL BE
LOCATED ON THE FACE OR ON THE DOOR OF EACH PANELBOARD OR AT EACH SWITCH ON A
SWITCHBOARD. WITHIN EACH PANELBOARD PRIOR TO FINAL ACCEPTANCE OF WORK IN PLACE.
I. LABEL ALL WIRING DEVICES WITH SOURCE PANELBOARD AND CIRCUIT NUMBER ON COVER PLATE.
SEE SPECIFICATIONS.
J. LABEL ALL NEW PANELBOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS WITH ENGRAVED
LAMINATED-PLASTIC NAMEPLATES MOUNTED WITH CORROSION-RESISTANT SCREWS. SEE
SPECIFICATIONS.
K. ALL INTERIOR OUTLET, JUNCTION AND PULL BOXES SHALL BE METALLIC, SIZED PER CODE FOR THE
NUMBER OF CONDUCTORS THEREIN.
L. ALL ELECTRICAL RACEWAYS SHALL BE CONCEALED IN THE WALLS AND ABOVE SUSPENDED CEILING
UNLESS OTHERWISE NOTED.
M. ALL CONDUCTORS SHALL BE #12 AWG MINIMUM TYPE THHN/THWN UNLESS OTHERWISE NOTED.
N. ALL CEILING MOUNTED ELECTRICAL DEVICES SHALL BE SUPPORTED FROM THE CEILING GRID, NOT
FROM CEILING TILE. LIGHTING SHALL BE SUPPORTED FROM STRUCTURE ABOVE.
O. ELECTRICAL PLANS ARE MOSTLY DIAGRAMMATIC. CONTRACTOR SHALL PROVIDE CONNECTIONS
BETWEEN FIXTURES AND LIGHTING CONTROL DEVICES SUCH AS OCCUPANCY SENSORS, LIGHT
SWITCHES, AND LIGHTING CONTROL PANEL TO PROVIDE AN OPERABLE LIGHTING SYSTEM.
P. IN THE EVENT OF ANY INCONSISTENCY BETWEEN ITEMS INDICATED ON THE PLANS AND/OR THE
SPECIFICATIONS, THE ONE WHICH PROVIDED THE MOST COMPLETE WORK OR HIGHER STANDARD
SHALL PREVAIL.
Q. SUPPLY AND INSTALL ALL REQUIRED SUPPORTS AND BRACING OF EQUIPMENT AND CONDUITS FOR
PROPER EQUIPMENT INSTALLATIONS AND CODE COMPLIANCE.
R. ALL EXPOSED CONDUITS SHALL BE INSTALLED AT RIGHT ANGLE TO ROOM OR STRUCTURE.
EXPOSED CONDUITS SHALL BE SUPPORTED FROM BUILDING STRUCTURE USING APPROVED PIPE
HANGERS.
S. ALL CONDUITS SHALL BE SIZED AS PER NEC UNLESS LARGER SIZES ARE NOTED ON THE DRAWINGS.
T. ALL CUTTING, PATCHING AND PAINTING REQUIRED FOR THE CONCEALED INSTALLATION OF
CONDUITS SHALL BE PROVIDED BY THE CONTRACTOR. DO NOT CUT OR DRILL STRUCTURAL
MEMBERS WITHOUT WRITTEN APPROVAL FROM STRUCTURAL ENGINEER. ALL CUTTING AND
PATCHING SHALL BE NEAT, AND PATCHING SHALL MATCH ADJACENT SURFACE AS TO TEXTURE AND
FINISH.
U. ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS OR CEILINGS SHALL BE SEALED IN
ACCORDANCE WITH A UL APPROVED SYSTEM THAT MAINTAINS THE INTEGRITY OF THE EXISTING
FIRE RATING. PROVIDE AN ENCLOSURE OF EQUAL FIRE RESISTANT RATING AROUND ALL FIXTURES
AND EQUIPMENT INSTALLED IN OR PENETRATING FIRE RATED SEPARATIONS.
V. ALL DATA CABLING TO BE PROVIDED BY THE OWNERS'S IT VENDOR. COORDINATE ROUGH-IN WORK
WITH OWNER'S IT VENDOR.
DRAWING INDEX
L001 COVER SHEET
L100 SITE LIGHTING PLAN - 306 IMPALA
L110 SITE LIGHTING CALCULATIONS - 306 IMPALA
L120 SITE LIGHTING PLAN - 400 MULBERRY
L130 SITE LIGHTING CALCULATIONS - 400 MULBERRY
L200 SITE LIGHTING CUTSHEETS
1999 BROADWAY
SUITE 2205
DENVER, CO
80202 | USA
(T) 720 644 5044
www.mazzetti.com
Project Number:
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
004-600611
2/22/2023 11:53:05 AML001
COVER SHEET
21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJB BSIMPALAREDEVELOPMENT
NOTES:
1. ALL LIGHTING FIXTURES SHALL BE UL LISTED.
2. ALL EXTERIOR AND SITE/LANDSCAPE LIGHTING MUST ADHERE TO ALL LOCAL LIGHTING ORDINANCES AND REQUIREMENTS. PROVIDE SHIELDING, GLARE CONTROL, HARDWARE OPTIONS AND ACCESSORIES AS NECESSARY TO
COMPLY.
3. CONFIRM ALL FIXTURE FINISHES, TRIMS, ACCESSORIES, ETC. FINAL APPROVAL OF ALL LIGHT FIXTURES TO BE BY THE ARCHITECT AND OWNER DURING SUBMITTAL PHASE AND PRIOR TO ANY ORDERING, PURCHASE OR
INSTALLATION OF LIGHT FIXTURES.
4. FIXTURES INSTALLED WITHIN RATED ASSEMBLIES SHALL BE PROVIDED AND/OR INSTALLED ACCORDINGLY TO MATCH THE RATING OF THE ASSEMBLY.
5. ALL TYPES E1, E2, AND E3 ARE LOCATED ALONG PRIVATE STREET, PARKING LOTS AND DRIVES, AND ARE IDEALLY LOCATED.
6. BOTH SITES ARE CLASSIFIED AS LC1.
7. TYPE E3 BOLLARD IS FULL CUTOFF WITH U1 RATING FROM LIGHT REFLECTED OFF OF STEM.
EX
CITY OF FORT
COLLINS
STANDARD
CITY OF FORT COLLINS
STANDARD
EXTERIOR POLE MOUNTED LED AREA LIGHT WITH
INTEGRAL DRIVER. UL WET LOCATION LISTED. PLEASE
NOTE LUMEN PACKAGE AND TYPE T3 DISTRIBUTION TO
BE CONFIRMED.
8250 73W 3000K 80 NON-DIM
18' EXISTING PED
POLE
25' EXISTING COBRA
HEAD
TYPE 3 -
E7 ILP SWP-1L-U-30-FINISH-10YR
WALL MOUNTED SCONCE WITH DIMMING DRIVER. UL
WET LOCATION LISTED.1000 10W 3000K 80 NON-DIM 6' AFG SYMMETRICAL B1-U0-G0
E6 VISION-3 FL1A-FINISH-RND-C4-K1-118-H1
SURFACE MOUNTED MONOPOINT WITH DIMMING
DRIVER. UL WET LOCATION LISTED.400 6W 3000K 80 ELV 10' AFG SYMMETRICAL N/A
E5 ALUZ
A5-ZOZO-STN-24"-27K-
GSF-DM-WET-LENGTH
EXTERIOR CATENARY LED GLOBE LIGHTING SPACED 24
INCHES APART ON CENTER. UL WET LOCATION LISTED.
PROVIDE WITH MOUNTING CABLE PLATES AND ALL
HARDWARE FOR COMPLETE AND FUNCTIONAL SYSTEM.
PROVIDE WITH STRAIGHT RUN.
48 1W 2700K 80 ELV 12' CATENARY LIGHT SYMMETRICAL N/A
E4 GENERATION
LIGHTING 863740112 EXTERIOR BUILDING MOUNTED LED SCONCE WITH
INTEGRAL DIMMING DRIVER. UL WET LOCATION LISTED.400 5W 3000K 80 ELV
BOTTOM OF FIXTURE
AT 6'-6" AFF
FLOOD FULL
CUT OFF N/A
E3 SIGNIFY
PBL-36-14L-100-WWG2-5-VOLT-FINI
SH
EXTERIOR GROUND MOUNTED LED BOLLARD WITH
INTEGRAL DIMMING DRIVER. UL WET LOCATION LISTED.343 5W 3000K 80 STEP 42 INCH BOLLARD
TYPE 5
CUT OFF B0-U1-G0
E2A ILP
SAS-2L-U-30-T4-UNV-FINISH-10YR
+ FSP-311/L20
EXTERIOR POLE MOUNTED LED PEDESTRIAN LIGHT
WITH INTEGRAL DIMMING DRIVER. UL WET LOCATION
LISTED.
2000 20W 3000K 80 STEP 20' ROUND POLE
TYPE 4 FULL
CUT OFF B1-U0-G1
E2 ILP
SAS-2L-U-30-T2-UNV-FINISH-10YR
+ FSP-311/L20
EXTERIOR POLE MOUNTED LED PEDESTRIAN LIGHT
WITH INTEGRAL DIMMING DRIVER. UL WET LOCATION
LISTED.
2000 20W 3000K 80 STEP 15' ROUND POLE
TYPE 2 FULL
CUT OFF B1-U0-G1
E1 ILP
SAS-2L-U-30-T3-UNV-FINISH-10YR
+ FSP-311/L20
EXTERIOR POLE MOUNTED LED AREA LIGHT WITH
INTEGRAL DIMMING DRIVER. UL WET LOCATION LISTED.
TO BE PROVIDED WITH A DERATED DRIVER TO LIMIT
LUMEN OUTPUT PER SCHEDULE. UL WET LOCATION.
2000 20W 3000K 80 STEP 20' ROUND POLE
TYPE 3 FULL
CUT OFF B1-U0-G1
TYPE MANUFACTURER MODEL DESCRIPTION LUMENS WATTS CCT CRI
DIMMING
INTERFACE MOUNTING HEIGHT DISTRIBUTION
TYPE BUG RATING
SITE LUMINAIRE SCHEDULE
SITE LUMEN LIMIT 118,915 PROPOSED LUMENS 101,503
E7 2 1000 2,000
E6 9 400 3,600
E5 130 48 6,240
SPORT COURTS 1,500 1.25 1,736 E4 44 400 17,600
DINING 1,389 1.25 8,263 E3 41 343 14,063
PORCH 6,610 1.25 8,263 E2A 4 2,000 8,000
SIDEWALK 19,706 1.25 24,633 E2 17 2,000 34,000
PARKING & DRIVES 60,817 1.25 76,021 E1 8 2,000 16,000
AREA TYPE SF BASE ALLOWANCE TOTAL TYPES QTY LUMENS TOTAL
EXTERIOR LIGHTING ALLOWANCE (HARDSCAPE AREA METHOD)
6 01/11/23 FDP RD 1
7 02/22/23 FDP RD 2 FDP SUBMITTALP
C CCCCCCCCCCCCCC
C C C C C CC
12 17
S
S
V A UL T
C A BL E
S
S
FO FF
F
F
W WWW WWS SSTTT
I
RI
RPROPOSED BUILDING B
TRANSFORMER LOCATION
PROPOSED BUILDING C
TRANSFORMER LOCATION
PROPOSED BUILDING A
TRANSFORMER LOCATION
PROPOSED BUILDING A
UTILITY METER AND MAIN
SWITCHGEAR LOCATION
PROPOSED BUILDING B
UTILITY METER AND MAIN
SWITCHGEAR LOCATION
PROPOSED BUILDING B
UTILITY METER AND MAIN
SWITCHGEAR LOCATION
E1
HA-52,54,z11
E1
HA-52,54,z11
E1
HA-52,54,z11
E1
HA-52,54,z11
E1
HA-52,54,z11
E1
HA-52,54,z11
E1
HA-52,54,z11
E1
HA-52,54,z11
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2
HA-56,58,z12
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E2B
HA-46,48,z12.2
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14 E4,z14 E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14E4,z14E4,z14E4,z14
E4,z14
EX
EX
E4,z14
EX
E2A
HA-60,62,z12.1
E2A
HA-60,62,z12.1
E2A
HA-60,62,z12.1
E2A
HA-60,62,z12.1
L2
L2
E3
HA-50,z13
E3
HA-50,z13
E3
HA-50,z13
E7,z17
E7,z17
E6,z16
E6,z16
E6,z16
E6,z16
EX
L1
L3
L3
L3
L3
E5,z15 E5,z15
E5,z15
E5
HA-64,z15
E5
HA-64,z15
E5
HA-64,z15
PROPERTY BOUNDARY
PROPERTY BOUNDARY
E2
HA-56,58,z12
E2B
HA-46,48,z12.2
E4,z14
E4,z14
L2
E2
HA-56,58,z12
E2B
HA-46,48,z12.2
1999 BROADWAY
SUITE 2205
DENVER, CO
80202 | USA
(T) 720 644 5044
www.mazzetti.com
Project Number:
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
004-600611
3/22/2023 9:29:20 AME110
SITE LIGHTING PLAN -
306 IMPALA
21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJB BSIMPALAREDEVELOPMENTKEYNOTES
L1 EXISTING STREET LIGHT OWNED AND OPERATED BY THE CITY OF FORT
COLLINS. LIGHT WAS INCLUDED IN PERMIT CALCULATIONS AND ASSUMED
TO REMAIN IN OPERATION BY THE CITY OF FORT COLLINS TO MAINTAIN
PROPER LIGHT LEVELS ALONG PUBLIC RIGHT OF WAY.
L2 EXISTING HPS POLE LUMINAIRES AS SHOWN BEING REPLACED BY THE CITY
TO THEIR STANDARD LED FIXTURES PER DISCUSSIONS WITH THE CITY OF
FORT COLLINS.
L3 PROVIDE LOCAL CONTROL FOR ON/OFF AND DIMMING CONTROL. ROUTE
CIRCUIT THROUGH PLCP FOR ASTRONOMICAL TIME CLOCK CONTROL.
BLDG A
KEY PLAN -306 IMPALA1" = 20'-0"E110
1 LIGHTING SITE PLAN - 306
6 01/11/23 FDP RD 1
7 02/22/23 FDP RD 2
P
C CCCCCCCCCCCCCC
C C C C C CC
12 17 41.7'25.3'41.7'25.3'41.7'25.3'41.7'
25.3'
25.3'41.7'41.7'25.3'25.3'41.7'25.3'41.7'
25.3'41.7'41.7'WVWV
WV HYDHY DV A UL T
E L EC
V A UL T
E L EC
V A UL T
E L EC
S
S
V A UL T
C A BL E
G
G
G
G
G
G
WW WW WWWWWWWWWWWWWW
WWWWWWWW
WW
WW WWWWWWWWWWWW WW WWWWWWWWWV
S
S
FO FF
F
F
W WWW WWS SSTTT
I
RI
RCalculation Summary
Label CalcType Units Avg Max Min Avg/Min Max/Min
Impala Drive - 306 Impala Illuminance Fc 1.17 5.1 0.0 N.A. N.A.
Overall Site Lighting Illuminance Fc 0.99 5.7 0.0 N.A. N.A.
Property Line - 306 Impala Illuminance Fc 0.53 5.2 0.0 N.A. N.A.
Property Line 10' Offset Illuminance Fc 0.63 5.3 0.0 N.A. N.A.
5.7
0.1 0.6 2.4 4.6 3.1 0.5 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.1 0.6 2.3 4.4 2.8 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0
0.1 0.7 2.0 2.9 1.7 0.3 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.0 0.0 0.0 0.0
0.4 0.9 1.7 2.1 1.2 0.4 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.4 0.4 0.2 0.0 0.0 0.0 0.0
0.6 1.3 2.2 2.7 2.2 1.2 0.8 0.5 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.7 0.7 0.3 0.1 0.0 0.0 0.0
0.4 0.9 1.7 2.5 2.2 1.2 0.9 0.9 1.1 1.3 1.4 1.2 1.2 1.4 1.5 1.3 1.1 0.9 0.9 1.0 1.2 1.2 1.2 1.1 0.9 0.7 0.6 1.1 1.1 0.4 0.1 0.0 0.0 0.0
0.1 0.4 0.6 0.6 0.4 0.3 0.5 0.7 1.5 2.2 2.4 1.7 1.3 1.8 2.3 2.3 1.4 1.0 1.0 1.2 2.1 2.4 2.3 1.5 1.1 1.0 0.9 2.3 1.6 0.6 0.3 0.1 0.0 0.0
0.1 0.4 0.5 0.4 0.2 0.2 0.8 0.8 0.3 0.5 1.8 0.7 0.9 1.0 1.2 1.3 1.2 1.0 0.3 0.8 1.7 1.2 1.1 1.3 1.4 1.3 1.3 2.9 2.0 0.9 0.4 0.1 0.1 0.0
0.1 0.3 0.7 0.4 0.1 0.1 0.2 3.6 0.9 1.2 1.5 1.7 1.6 1.7 2.8 2.2 1.0 0.5 0.2 0.1 0.0
0.1 0.3 1.1 0.7 0.1 1.3 1.7 1.9 2.1 1.9 1.8 2.2 2.1 1.3 0.6 0.3 0.1 0.1
0.1 0.4 2.1 1.4 0.2 4.1 2.3 2.4 2.3 2.1 2.0 2.0 2.2 1.5 0.6 0.3 0.1 0.1
0.2 0.5 3.0 1.7 0.5 3.2 2.4 2.6 2.3 2.2 2.3 2.3 2.5 1.4 0.5 0.2 0.1 0.1
0.2 0.6 2.5 1.3 1.5 4.5 1.4 1.8 2.1 2.3 2.3 2.4 2.5 3.0 1.4 0.4 0.1 0.1 0.0
0.3 0.7 1.5 0.7 0.3 0.1 5.3 4.7 1.3 1.4 1.8 1.6 2.0 2.2 2.3 2.8 1.1 0.3 0.1 0.1 0.0
0.4 1.0 1.4 0.9 0.6 1.0 4.2 1.0 0.5 1.1 3.5 4.7 2.1 2.2 2.9 1.4 1.5 1.3 1.3 1.0 0.9 1.2 1.6 1.4 2.5 2.5 2.0 2.0 0.9 0.2 0.1 0.0 0.0
0.5 1.1 1.4 1.1 0.8 0.9 1.0 0.9 0.8 0.9 1.2 1.2 1.1 1.0 1.4 1.2 1.4 1.4 1.2 1.1 0.9 0.9 1.2 1.6 1.7 3.1 2.7 1.5 1.2 0.6 0.2 0.1 0.1 0.0
0.6 1.2 1.4 1.2 0.9 1.0 1.0 3.4 1.0 0.8 1.3 1.2 0.9 1.0 1.3 1.1 1.7 2.0 1.2 1.1 0.9 1.1 3.0 2.5 5.0 2.8 2.4 1.0 0.8 0.5 0.3 0.2 0.1 0.0
0.9 1.3 1.5 1.2 0.9 4.1 1.7 1.4 0.9 1.1 5.6 1.9 0.9 1.1 1.2 1.0 2.0 3.4 1.4 1.8 0.5 0.5 0.5 0.4 0.3 0.2 0.0
1.1 1.6 1.7 1.4 0.9 1.2 1.3 1.0 1.5 1.8 0.7 1.0 1.2 1.1 2.2 3.7 1.2 2.1 2.5 0.3 0.5 0.6 0.5 0.3 0.1
1.2 1.6 1.8 1.4 0.7 0.8 0.9 1.2 1.2 2.2 2.9 4.6 1.7 2.6 1.0 0.4 0.5 0.7 0.6 0.4 0.1
1.3 1.8 2.0 1.8 0.7 1.0 0.8 1.2 1.1 1.6 1.6 2.2 2.7 1.1 0.4 0.5 0.7 0.7 0.4 0.2
1.4 1.9 2.3 2.1 2.4 3.5 1.0 0.9 1.2 1.1 1.3 1.2 2.0 0.8 2.0 1.2 0.5 0.5 0.7 0.7 0.4 0.2
1.5 1.9 2.2 1.9 0.7 4.0 1.1 1.1 1.2 1.1 1.1 1.0 3.8 0.6 1.5 1.1 0.5 0.6 0.7 0.7 0.3 0.1
1.7 1.9 1.9 1.4 0.5 0.1 2.3 0.9 1.0 1.3 1.2 0.9 0.8 1.1 1.3 1.9 1.2 0.5 0.6 0.7 0.7 0.3 0.1
1.8 1.8 1.6 1.0 0.8 3.1 0.9 1.0 1.2 1.2 0.9 0.9 1.9 2.2 2.4 1.2 0.5 0.6 0.8 0.7 0.4 0.1
2.0 1.7 1.4 0.9 0.8 3.1 0.9 0.9 1.1 1.1 0.9 1.0 2.4 0.8 2.5 1.2 0.6 0.6 0.8 0.7 0.4 0.1
2.2 1.6 1.5 0.9 0.3 1.0 0.9 0.9 1.2 1.1 0.9 0.9 3.0 3.4 1.8 1.1 0.5 0.6 0.7 0.7 0.5 0.2
2.3 1.5 2.0 1.1 0.3 1.2 0.9 1.0 1.2 1.1 0.9 0.8 0.8 0.8 1.4 1.1 0.5 0.6 0.7 0.7 0.4 0.2
2.4 1.5 3.2 1.8 0.9 3.2 1.2 1.1 1.2 1.1 1.0 0.9 0.8 3.2 1.5 1.2 0.5 0.6 0.7 0.7 0.4 0.2
2.3 1.5 3.3 1.8 0.6 3.1 1.0 0.9 0.9 0.9 0.9 0.9 2.7 0.5 2.2 1.2 0.5 0.6 0.7 0.7 0.4 0.1
2.1 1.4 2.2 0.9 0.3 2.8 1.1 0.9 0.9 0.9 1.0 0.9 2.6 2.3 1.1 0.5 0.6 0.8 0.7 0.4 0.1
1.9 1.4 1.3 0.5 0.3 5.6 1.4 1.2 1.4 1.3 1.1 1.1 2.7 1.1 1.8 1.0 0.5 0.6 0.8 0.8 0.5 0.1
1.6 1.2 0.9 0.3 1.0 4.4 0.7 1.4 1.8 1.6 1.3 1.2 2.5 1.0 0.7 0.4 0.6 0.8 0.8 0.5 0.2
1.3 1.0 0.6 0.2 0.1 1.2 1.4 1.7 1.6 1.2 1.1 0.4 0.7 0.6 0.4 0.6 0.8 0.8 0.6 0.0
1.0 0.9 0.6 0.3 0.3 0.4 0.6 0.7 2.7 3.2 0.6 0.8 1.5 1.4 1.2 1.3 1.6 1.5 1.0 0.9 1.1 1.3 4.4 2.3 1.2 1.2 1.1 0.9 0.7 0.8 0.9 0.7 0.5 0.2
0.9 0.8 0.6 0.5 0.6 1.0 1.9 2.3 2.5 1.8 1.5 2.0 2.7 2.8 1.8 1.8 2.6 2.8 2.6 2.2 2.6 2.8 2.7 2.2 2.5 2.6 2.3 1.5 1.3 1.1 1.0 0.7 0.4 0.1
0.9 0.9 0.7 0.6 0.7 0.7 1.0 1.1 1.2 1.2 1.1 1.1 1.8 4.7 1.1 1.2 1.4 1.4 1.3 1.3 1.4 1.4 1.4 1.3 1.3 1.3 1.3 1.3 1.3 1.1 0.9 0.6 0.2 0.1
1.2 1.4 1.7 1.9 1.4 0.9 0.6 0.5 0.5 0.4 0.4 0.5 0.4 0.4 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.7 0.8 0.9 0.9 1.0 0.9 0.6 0.3 0.1 0.0
1.3 1.8 2.3 2.4 2.0 1.3 0.9 0.8 0.7 0.5 0.5 0.5 0.6 0.6 0.6 0.6 0.5 0.5 0.6 0.6 0.6 0.6 0.7 0.7 0.8 1.0 1.0 1.0 0.9 0.6 0.3 0.2 0.1 0.0
1.2 1.6 1.6 1.0 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.8 0.8 0.9 1.0 1.0 0.8 0.5 0.4 0.3 0.1 0.1 0.0
1.1 1.9 2.1 0.8 0.3 0.3 0.4 0.5 0.6 0.7 0.7 0.7 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.6 0.6 0.6 0.7 0.8 0.9 0.8 0.7 0.5 0.4 0.3 0.2 0.1 0.0 0.0
1.1 2.6 3.5 1.2 0.3 0.2 0.2 0.2 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.3 0.2 0.2 0.1 0.0 0.0 0.0 0.0
1.1 3.1 5.1 1.6 0.4 0.2 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.0 0.1 0.1 0.2 0.2 0.1 0.1 0.0 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0
1.1 2.9 4.7 1.5 0.4 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
1999 BROADWAY
SUITE 2205
DENVER, CO
80202 | USA
(T) 720 644 5044
www.mazzetti.com
Project Number:
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:
004-600611
3/22/2023 9:29:23 AML110
SITE LIGHTING
CALCULATIONS -306
IMPALA
21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COSE BSIMPALAREDEVELOPMENT
1" = 20'-0"L110
1 LIGHTING SITE PLAN PHOTOMETRICS - 306
6 01/11/23 FDP RD 1
7 02/22/23 FDP RD 2
8 03/22/23 FDP RD 3 FDP SUBMITTALP
CCCCCOWNER:
KEELER, JACK LEE/
GAIL, MARGARET
2302 W MULBERRY
ST.OWNER:
RICKETTS, THERESA
A.
2300 W MULBERRY ST.
OWNER:
VILLAGES, LTD.
400 IMPALA
CIR.
SIKORSKI, MITCHELL ANDREW
5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)9HC PARKING
C A BL E
C
TC
C
T
C
WV
HYDV A UL T
F.O .
G
G
G
G
G
E
E
E
E
E
S
CELECFWWSTIRIRE4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E4,z14
E3,z13E3,z13
E3,z13
E2,z12
E2,z12
E1,z11
E3,z13
E3,z13
E3,z13
E3,z13
E3,z13
E2,z12
E3,z13 E3,z13 E3,z13
E3,z13
E3,z13
PROPERTY BOUNDARY
1999 BROADWAY
SUITE 2205
DENVER, CO
80202 | USA
(T) 720 644 5044
www.mazzetti.com
Project Number:
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:
004-600611
3/22/2023 9:29:21 AME120
SITE LIGHTING PLAN -
400 MULBERRY
21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COSE BSIMPALAREDEVELOPMENT
1" = 20'-0"E120
1 LIGHTING SITE PLAN - 400
1 04/13/22 PDP
3 06/08/22 PDP RD 2
4 07/27/22 PDP RD 3
5 10/19/22 PDP RD 4
6 01/11/23 FDP RD 1 FDP SUBMITTALP
CCCCCOWNER:
KEELER, JACK LEE/
GAIL, MARGARET
2302 W MULBERRY
ST.OWNER:
RICKETTS, THERESA
A.
2300 W MULBERRY ST.
OWNER:
VILLAGES, LTD.
400 IMPALA
CIR.
SIKORSKI, MITCHELL ANDREW
5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)9HC PARKING
MANHOLE BURIED
IN SNOW PILE
NO INVERTS
C A BL E
C
TC
C
T
C
WV
HYDV A UL T
F.O .
G
G
G
G
G
E
E
E
E
E
S
CELECFWWS 45° AND CLEANOUT
MANHOLE
T IRIR0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.1 0.1 0.2 0.2 0.3 0.1 0.1 1.1 0.3 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.1 0.1 0.2 0.3 0.3 1.0 0.3 0.0 0.4 0.8 0.0 0.0 0.0 0.0 0.0
0.0 0.1 0.2 0.3 0.4 0.4 0.5 0.0 0.0 0.0 0.0 0.0
0.0 0.1 0.2 0.4 0.5 0.6 0.6 2.6 0.1 0.0 0.0 0.0 0.0
0.0 0.1 0.2 0.4 0.6 0.7 0.7 4.2 0.2 0.0 0.0 0.0 0.0
0.0 0.1 0.2 0.4 0.6 0.8 1.0 0.4 0.1 0.0 0.0 0.0 0.0
0.0 0.1 0.2 0.5 0.7 0.9 0.9 4.7 0.1 0.0 0.0 0.0 0.0
0.0 0.1 0.2 0.5 0.7 0.9 0.6 0.3 0.1 0.0 0.0 0.0 0.0
0.0 0.2 0.3 0.5 0.7 0.9 0.7 0.3 0.5 0.1 0.0 0.0 0.0 0.0
0.1 0.2 0.3 0.5 0.8 1.0 1.4 1.8 0.2 0.2 1.6 1.5 0.3 0.3 0.8 0.0 0.0 0.0 0.0 0.0
0.0 0.1 0.4 0.4 0.5 0.9 1.1 1.0 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.1 0.1 0.5 0.4 0.5 0.7 0.8 0.8 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.1 0.1 0.2 0.7 0.6 0.5 0.5 0.7 0.5 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.1 0.1 0.3 1.0 0.9 1.2 0.4 0.6 0.7 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.9 0.8 3.0 0.4 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.7 0.5 1.1 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.5 0.4 3.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.3 0.9 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 3.9 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 4.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.1 1.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.0 0.3 2.0 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.6 0.8 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.5 0.6 0.6 0.5 0.5 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.4 0.4 0.4 0.4 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Calculation Summary
Label CalcType Units Avg Max Min Avg/Min Max/Min
Mulberry Site Illuminance Fc 0.14 4.8 0.0 N.A. N.A.
Property Line - 10' Offset Illuminance Fc 0.00 0.1 0.0 N.A. N.A.
Property Line - 400 Impala Illuminance Fc 0.03 0.5 0.0 N.A. N.A.
1999 BROADWAY
SUITE 2205
DENVER, CO
80202 | USA
(T) 720 644 5044
www.mazzetti.com
Project Number:
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:
004-600611
3/22/2023 9:29:24 AML130
SITE LIGHTING
CALCULATIONS -400
MULBERRY
21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COSE BSIMPALAREDEVELOPMENT6 01/11/23 FDP RD 1
7 02/22/23 FDP RD 2
8 03/22/23 FDP RD 3 FDP SUBMITTAL1" = 20'-0"L130
1 LIGHTING SITE PLAN PHOTOMETRICS - 400
P
1999 BROADWAY
SUITE 2205
DENVER, CO
80202 | USA
(T) 720 644 5044
www.mazzetti.com
Project Number:
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:
004-600611
2/22/2023 11:53:09 AML200
SITE LIGHTING
CUTSHEETS
21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJB BSIMPALAREDEVELOPMENT6 01/11/23 FDP RD 1
7 02/22/23 FDP RD 2 FDP SUBMITTALP