HomeMy WebLinkAboutIMPALA REDEVELOPMENT - FDP230001 - SUBMITTAL DOCUMENTS - ROUND 3 - ARCHITECTURAL DETAILSIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG AIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG AIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A IMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG AIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG AIMPALA DRIVEIMPALA CIRCLE
BLDG B BLDG C
BLDG A
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:2/22/2023 9:20:00 AMA001
SOLAR ANALYSIS -
306 IMPALAIMPALA RENOVATIONS21-017.00400 IMPALA CIRCLEFORT COLLINS, COLORADO, 80521MD CR
1" = 40'-0"1 SOLAR STUDY - DECEMBER 21 @ 10AM
1" = 40'-0"2 SOLAR STUDY - DECEMBER 21 @ 12PM
1" = 40'-0"3 SOLAR STUDY - DECEMBER 21 @ 2PM
1" = 40'-0"4 SOLAR STUDY - JUNE 21 @ 10AM
1" = 40'-0"5 SOLAR STUDY - JUNE 21 @ 12PM
1" = 40'-0"6 SOLAR STUDY - JUNE 21 @ 2PM
0 80
GRAPHIC SCALE
40
05 01/11/23 FDP RD 1
06 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 7:51:45 PMA002
3D VIEWS -306
IMPALAIMPALA RENOVATIONS21-017.00400 IMPALA CIRCLEFORT COLLINS, COLORADO, 80521MD CR
1 VIEW FROM SW
2 VIEW FROM NW
KEY PLAN -306 IMPALA
1
2
BUILDING B BUILDING C BUILDING A
BUILDING BBUILDING C BUILDING A
05 01/11/23 FDP RD 1
06 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 7:55:24 PMA003
3D VIEWS -306
IMPALAIMPALA RENOVATIONS21-017.00400 IMPALA CIRCLEFORT COLLINS, COLORADO, 80521MD CR
2 VIEW FROM W OLIVE ST
1 CORNER OF IMPALA AND IMPALA CIRCLE
KEY PLAN -306 IMPALA
1
2
BUILDING B BUILDING A
BUILDING ABUILDING B
BUILDING A -COMMUNITY CENTER
05 01/11/23 FDP RD 1
06 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
WH
WHWH WH
WH
WH
WH
WH
11'2'1 2 6 7 8 9
A
C
D
E
F
G
H
I
UNIT TYPE 1B-H1
U102 UNIT TYPE 2B
U103
UNIT TYPE 2B
U104
UNIT TYPE 2B
U105
BIKE STORAGE
111 6'-5 3/4"4'-9 3/4"24'-1"24'-1"7'-0 1/2"4'-3"12
UNIT TYPE 3B
U101
TEEN /
COMPUTER
AREA
FLEXIBLE AREA
KITCHEN
STORAGE
OFFICE
OFFICE
43 5 10 11
166'-5 1/8"
3'-11 1/2" 7'-5 1/4"48'-11 1/2"7'-7 1/2" 7'-4 3/4" 10'-3" 7'-4 3/4" 28'-3 1/2" 7'-9 1/2" 25'-3 1/8" 12'-0 3/4"64'-3 1/4"PATIO PATIO
PATIO PATIO PATIO
PATIO
UNIT TYPE 2B
U106
A201A
1
A201A
2
A201A 3
A201A4
WATER ENTRY
122
1 2 6 7 8 9
A
C
D
E
F
G
H
I
UNIT TYPE 1C
U201
UNIT TYPE 2B
U202
UNIT TYPE 2B
U203
UNIT TYPE 2B
U204
3:1212
RESIDENT
STORAGE
2116:126:126:12 3:123:129:12
9:12 6:123:123:126:12
6:123:1243 5 10 11
166'-5 1/8"
3'-11 1/2" 7'-5 1/4"48'-11 1/2"7'-7 1/2" 7'-4 3/4" 10'-3" 7'-4 3/4" 28'-3 1/2" 7'-9 1/2" 25'-3 1/8" 12'-0 3/4"6'-5 3/4"4'-9 3/4"24'-1"24'-1"4'-9 3/4"2'-2 3/4"4'-3"70'-9"A201A
1
A201A
2
A201A 3
A201A4
9:12
9:123:126:126:12
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:2/21/2023 3:59:02 PMA101A
BLDG A -FLOOR PLAN
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 LEVEL 1 PLAN
BLDG A
KEY PLAN -306 IMPALA
1" = 10'-0"2 LEVEL 2 PLAN
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
0 20 30 4010
GRAPHIC SCALE
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
PLOT DATE:3/21/2023 10:37:14 AM1" = 10'-0"1 LEVEL 1 PLAN
11'2'1 2 6 7 8 9
A
C
D
E
F
G
H
I70'-9"6'-5 3/4"4'-9 3/4"24'-1"24'-1"4'-9 3/4"2'-2 3/4"4'-3"3:12124351011
166'-5 1/8"
3'-11 1/2" 7'-5 1/4"48'-11 1/2"7'-7 1/2" 7'-4 3/4" 10'-3" 7'-4 3/4" 28'-3 1/2" 7'-9 1/2" 25'-3 1/8" 12'-0 3/4"6:126:12
6:12
6:126:126:12
9:12 9:12
6:12 6:126:129:12 9:12
6:12 6:12
6:12 3:123:129:12
6:123:12
A201A
1
A201A
2
A201A 3
A201A4
3:123:123:126:129:12
6:12 3:126:126:126:126:123575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 3:59:03 PMA102A
BLDG A -ROOF PLAN
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 ROOF PLAN
BLDG A
KEY PLAN -306 IMPALA
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
0 20 30 4010
GRAPHIC SCALE
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
126789
133' -4"
TO ROOF
12
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
4 351011
122' -10"
TO CLUBHOUSE ROOF
1'-0 5/8"9'-0 3/8"1'-2 7/8"8'-11 5/8"5'-0"20'-3 1/2"33'-4"100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
1 2 6 7 8 9
133' -4"
TO ROOF
12
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
43 5 10 11
122' -10"
TO CLUBHOUSE ROOF
1'-0 5/8"6'-8 7/8"2'-3 1/2"1'-2 7/8"8'-11 5/8"5'-0"20'-3 1/2"33'-4"3
0
3
100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
A C D E F G H I
133' -4"
TO ROOF
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
122' -10"
TO CLUBHOUSE ROOF
1'-0 5/8"9'-0 3/8"1'-2 7/8"8'-11 5/8"5'-0"25'-3 1/2"38'-4"100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
ACDEFGHI
133' -4"
TO ROOF
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
122' -10"
TO CLUBHOUSE ROOF
13'-0 1/2"1'-0 5/8"9'-0 3/8"1'-2 7/8"8'-11 5/8"5'-0"38'-4"25'-3 1/2"3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 3:59:20 PMA201A
BLDG A -ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONSBLDG A
KEY PLAN -306 IMPALA1" = 10'-0"1 NORTH ELEVATION
1" = 10'-0"2 SOUTH ELEVATION (IMPALA DRIVE)
1" = 10'-0"3 WEST ELEVATION
1" = 10'-0"4 EAST ELEVATION
0 20 30 4010
GRAPHIC SCALE
BUILDING ADDRESS SIGNAGE
PER IFC 505.1. MINIMUM 8"
NUMERALS ON CONTRASTING
BACKGROUND
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
PLOT DATE:3/21/2023 10:37:14 AM
100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
126789
133' -4"
TO ROOF
12
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
4 351011
122' -10"
TO CLUBHOUSE ROOF
100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
1 2 6 7 8 9
133' -4"
TO ROOF
12
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
43 5 10 11
122' -10"
TO CLUBHOUSE ROOF
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -LIGHT BROWN
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03 -SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04 -SHERWIN WILLIAMS "FIRED BRICK"
100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
A C D E F G H I
133' -4"
TO ROOF
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
122' -10"
TO CLUBHOUSE ROOF
100' -0"
LEVEL 1 -UNITS
110' -2 1/2"
LEVEL 2
108' -11 5/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
ACDEFGHI
133' -4"
TO ROOF
98' -6"
LEVEL 1 -CLUBHOUSE
112' -6"
TOP CLUBHOUSE
122' -10"
TO CLUBHOUSE ROOF
13'-0 1/2"1'-0 5/8"9'-0 3/8"1'-2 7/8"8'-11 5/8"5'-0"38'-4"25'-3 1/2"D1
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 3:59:40 PMA202A
BLDG A -COLORED
ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 EAST ELEVATION (OPEN SPACE)
1" = 10'-0"2 WEST ELEVATION (IMPALA DRIVE)
1" = 10'-0"3 WEST ELEVATION
BLDG A
KEY PLAN -306 IMPALA020304010
GRAPHIC SCALE
1" = 10'-0"4 EAST ELEVATION
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
PLOT DATE:3/21/2023 10:37:14 AM1" = 10'-0"1 NORTH ELEVATION
1" = 10'-0"2 SOUTH ELEVATION (IMPALA DRIVE)
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 4:00:24 PMA301A
BLDG A -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 EAST FACADE (OPEN SPACE)
2 WEST FACADE (IMPALA DRIVE)
BUILDING ENTRY CLUBHOUSE ENTRY
BUILDING ENTRYCLUBHOUSE ENTRY
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
PLOT DATE:3/21/2023 10:37:14 AM NORTH FACADE (OPEN SPACE)
SOUTH FACADE (IMPALA DRIVE)
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 4:00:59 PMA302A
BLDG A -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 SW CORNER
2 CORNER-NE
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
PLOT DATE:3/21/2023 10:37:14 AM E
WHWH14'
WHWHWHWHWHWHWHWHWH
WH
1
2
3
4
5
6
7
8
9
10
11
ABCDEFGHI
730 SF
UNIT TYPE 1A
U101
939 SF
UNIT TYPE 2B-H1
U102
939 SF
UNIT TYPE 2B
U103
732 SF
UNIT TYPE 1A
U104
1,165 SF
UNIT TYPE 3A
U105
939 SF
UNIT TYPE 2B
U106
939 SF
UNIT TYPE 2B-H1
U107
1,165 SF
UNIT TYPE 3A
U108
133 SF
BIKE STORAGE
109
133 SF
BIKE STORAGE
110
70'-2 7/8"
4'-11 7/8"
11 3/4"
4'-9 3/4"24'-1"24'-1"4'-9 3/4"
2'-2 3/4"
4'-3"164'-1 1/2"14'-8 3/4"13'-9 1/4"11'-1 1/2"7'-1 3/4"28'-3 1/2"28'-3 1/2"7'-1 3/4"11'-1 1/2"13'-9 1/4"14'-8 3/4"199 SF
RISER ROOM
111
A2011
A201 2
A201
3
A201
4
5'-0 1/2"14'-0"1'-8 1/2"11'-3 1/2"
6'-7 3/4"
11'-3 1/2"
PATIO PATIO
PATIO
PATIO
PATIOPATIO
PATIO
PATIO
362 SF
STAIR 01
S101
362 SF
STAIR 02
S102
12
1
2
3
4
5
6
7
8
9
10
11
ABCDEFGHI
876 SF
UNIT TYPE 2A
U201
939 SF
UNIT TYPE 2B
U202
939 SF
UNIT TYPE 2B
U203
879 SF
UNIT TYPE 2A
U204
1,165 SF
UNIT TYPE 3A
U205
939 SF
UNIT TYPE 2B
U206
939 SF
UNIT TYPE 2B
U207
1,165 SF
UNIT TYPE 3A
U208
4:12
6:126:124:12
6:126:124:12
5:12
5:12
70'-2 7/8"
4'-11 7/8"
11 3/4"
4'-9 3/4"24'-1"24'-1"4'-9 3/4"
2'-2 3/4"
4'-3"150'-1 1/2"14'-8 3/4"13'-9 1/4"11'-1 1/2"7'-1 3/4"28'-3 1/2"28'-3 1/2"7'-1 3/4"11'-1 1/2"13'-9 1/4"14'-8 3/4"A201B 2 A201B1
A201B
3
A201B
4
4:124:12
4'-3 3/16"
11'-3 1/2"
4'-9 3/4"
368 SF
STAIR 01
S201
368 SF
STAIR 02
S202
12
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:2/21/2023 5:35:44 PMA101B
BLDG B -FLOOR PLAN
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 LEVEL 1 PLAN
0 20 30 4010
GRAPHIC SCALE
BLDG CBLDG B
BLDG A
KEY PLAN -306 IMPALA
1" = 10'-0"2 LEVEL 2 PLAN
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
0 20 30 4010
GRAPHIC SCALE
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
1
2
3
4
5
6
7
8
9
10
11
ABCDEFGHI
6:12 6:12
6:126:12 9:129:129:129:129:129:129:129:126:126:12
6:1270'-2 7/8"
4'-11 7/8"
11 3/4"
4'-9 3/4"24'-1"24'-1"4'-9 3/4"
2'-2 3/4"
4'-3"150'-1 1/2"14'-8 3/4"13'-9 1/4"11'-1 1/2"7'-1 3/4"28'-3 1/2"28'-3 1/2"7'-1 3/4"11'-1 1/2"13'-9 1/4"14'-8 3/4"A201B 2 A201B1
A201B
3
A201B
4
4:12 4:12
6:12 6:12
6:12 6:12
4:126:126:126:12 6:12
4:126:12 6:12
5:12 4:12
5:12 4:126:124:12
6:1212
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 5:35:45 PMA102B
BLDG B -ROOF PLAN
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 ROOF PLAN
BLDG CBLDG B
BLDG A
KEY PLAN -306 IMPALA
0 20 30 4010
GRAPHIC SCALE
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
1234567891011
135' -6"
TO ROOF
5'-0" 9'-1 1/8"1'-2 7/8"8'-10 7/8"1'-0 5/8"15'-2 1/2"36'-2"99' -4"
LEVEL 1 -SOUTH
12
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
1 2 3 4 5 6 7 8 9 10 11
135' -6"
TO ROOF
15'-2 1/2"1'-0 5/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"5'-0"36'-2"99' -4"
LEVEL 1 -SOUTH
12
BUILDING ADDRESS
SIGNAGE PER IFC
505.1. MINIMUM 8"
NUMERALS ON
CONTRASTING
BACKGROUND
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
ABCDEFGHI
135' -6"
TO ROOF
15'-2 1/2"1'-0 5/8"8'-10 7/8"1'-2 7/8"9'-9 1/8"4'-4"36'-2"99' -4"
LEVEL 1 -SOUTH
GAS METER
LOCATION,
RE:CIVIL
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
A B C D E F G H I
135' -6"
TO ROOF
15'-2 1/2"1'-0 5/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"5'-0"36'-2"99' -4"
LEVEL 1 -SOUTH
ELECTRIC
LOCATION METER,
RE:CIVIL
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 5:36:06 PMA201B
BLDG B -ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 EAST ELEVATION (OPEN SPACE)
1" = 10'-0"2 WEST ELEVATION (IMPALA DRIVE)
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 NORTH ELEVATION
BLDG CBLDG B
BLDG A
KEY PLAN -306 IMPALA020304010
GRAPHIC SCALE
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
1234567891011
135' -6"
TO ROOF
5'-0" 9'-1 1/8"1'-2 7/8"8'-10 7/8"1'-0 5/8"15'-2 1/2"35'-6"12
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
1 2 3 4 5 6 7 8 9 10 11
135' -6"
TO ROOF
15'-2 1/2"1'-0 5/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"5'-0"35'-6"12
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
ABCDEFGHI
135' -6"
TO ROOF
99' -4"
LEVEL 1 -SOUTH15'-2 1/2"1'-0 5/8"8'-10 7/8"1'-2 7/8"9'-9 1/8"4'-4"36'-2"ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -LIGHT BROWN
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03 -SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04 -SHERWIN WILLIAMS "PRIVILEGE GREEN"
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
95' -0"
TO FOOTING
A B C D E F G H I
135' -6"
TO ROOF
15'-2 1/2"1'-0 5/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"5'-0"35'-6"3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 5:36:29 PMA202B
BLDG B -COLORED
ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 EAST ELEVATION (OPEN SPACE)
1" = 10'-0"2 WEST ELEVATION (IMPALA DRIVE)
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 NORTH ELEVATION
0 64 96 12832
GRAPHIC SCALE
BLDG CBLDG B
BLDG A
KEY PLAN -306 IMPALA
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 5:37:08 PMA301B
BLDG B -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 EAST FACADE (OPEN SPACE)
2 WEST FACADE (IMPALA DRIVE)
PATIOS WITH GATES
BUILDING ENTRIES
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 5:37:38 PMA302B
BLDG B -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 SW CORNER
2 SE Corner
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
UP
UP
UP
WH
WH
UP
UP
UP
WH
WH
1
2
3
4
5
6
7
8
9
10
ABCDEGH
171'-0"14'-8 3/4"24'-7 3/4"15'-0 1/4"24'-6 1/2"15'-0 1/4"22'-7 3/4"15'-0 1/4"24'-7 3/4"14'-8 3/4"70'-9"
6'-3"29'-1 1/2"8'-5 1/2"10'-0"12'-8"4'-3"
732 SF
UNIT TYPE 1A
U101
133 SF
BIKE STORAGE
111
647 SF
UNIT TYPE 1B-H1
U102
647 SF
UNIT TYPE 1B-H1
U103
647 SF
UNIT TYPE 1B-H1
U104
732 SF
UNIT TYPE 1A
U105 PATIOPATIOPATIOPATIOPATIOPATIOPATIOPATIO1,165 SF
UNIT TYPE 3A
U106
745 SF
UNIT TYPE 1C
U107
745 SF
UNIT TYPE 1C
U108
745 SF
UNIT TYPE 1C
U109
1,165 SF
UNIT TYPE 3A-H1
U110
133 SF
WATER ENTRY
115
169 SF
RESIDENT
STORAGE
112
169 SF
BIKE STORAGE
113
170 SF
BIKE STORAGE
114
A201C 1
1 A201C2
A201C
3
A201C
4
1'-8"6'-4 1/2"1'-8 1/2"F
1
2
3
4
5
6
7
8
9
10
ABCDEGH
879 SF
UNIT TYPE 2A
U201
647 SF
UNIT TYPE 1B
U202
647 SF
UNIT TYPE 1B
U203
647 SF
UNIT TYPE 1B
U204
879 SF
UNIT TYPE 2A
U205
1,165 SF
UNIT TYPE 3A
U206
745 SF
UNIT TYPE 1C
U207
745 SF
UNIT TYPE 1C
U208
745 SF
UNIT TYPE 1C
U209
1,165 SF
UNIT TYPE 3A
U210
169 SF
RESIDENT
STORAGE
211
169 SF
RESIDENT
STORAGE
212
169 SF
RESIDENT
STORAGE
213
156 SF
BUILDING
STORAGE
214
4:12
6:126:124:12
6:126:124:12
4:126:126:124:126:126:124:12
4:12
171'-0"14'-8 3/4"24'-7 3/4"15'-0 1/4"24'-6 1/2"15'-0 1/4"22'-7 3/4"15'-0 1/4"24'-7 3/4"14'-8 3/4"70'-9"
6'-3"29'-1 1/2"8'-5 1/2"10'-0"12'-8"4'-3"
A201C 1
1 A201C2
A201C
3
A201C
4
F
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:2/21/2023 6:19:19 PMA101C
BLDG C -FLOOR PLANS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 LEVEL 1 PLAN
0 20
GRAPHIC SCALE
10
BLDG C
KEY PLAN -306 IMPALA1" = 10'-0"2 LEVEL 2 PLAN
0 20
GRAPHIC SCALE
10
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
DN
DN
DN
WHWH
1
2
3
4
5
6
7
8
9
10
ABCDEGH
879 SF
UNIT TYPE 2A
U301
647 SF
UNIT TYPE 1B
U302
647 SF
UNIT TYPE 1B
U303
647 SF
UNIT TYPE 1B
U304
745 SF
UNIT TYPE 1C
U307
745 SF
UNIT TYPE 1C
U309
1,169 SF
UNIT TYPE 3A
U310
170 SF
RESIDENT
STORAGE
311
170 SF
RESIDENT
STORAGE
312
170 SF
RESIDENT
STORAGE
313
93 SF
RESIDENT
STORAGE
315
91 SF
RESIDENT
STORAGE
314
4:12
745 SF
UNIT TYPE 1C
U308 171'-0"14'-8 3/4"24'-7 3/4"15'-0 1/4"24'-6 1/2"15'-0 1/4"22'-7 3/4"15'-0 1/4"24'-7 3/4"14'-8 3/4"70'-9"
6'-3"29'-1 1/2"8'-5 1/2"10'-0"12'-8"4'-3"
A201C 1
1 A201C2
A201C
3
745 SF
UNIT TYPE 1C
U305
745 SF
UNIT TYPE 1C
U306
A201C
4
4:12F
1
2
3
4
5
6
7
8
9
10
ABCDEGH
6:12 6:126:126:126:126:126:126:12171'-0"14'-8 3/4"24'-7 3/4"15'-0 1/4"24'-6 1/2"15'-0 1/4"22'-7 3/4"15'-0 1/4"24'-7 3/4"14'-8 3/4"70'-9"
6'-3"29'-1 1/2"8'-5 1/2"10'-0"12'-8"4'-3"
A201C 1
1 A201C2
A201C
36:126:12 6:12 6:12 6:12
6:12
4:12
6:126:124:12
6:126:126:12 6:12
4:124:12
A201C
4
F
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:BUILDING C2/21/2023 6:19:21 PMA102C
BLDG C -FLOOR PLANS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 LEVEL 3 PLAN
BLDG C
KEY PLAN -306 IMPALA1" = 10'-0"2 ROOF PLAN
01 01/11/23 FDP RD 1
03/22/23 PERMIT
0 20
GRAPHIC SCALE
10020
GRAPHIC SCALE
10
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
1 2 3 4 5 6 7 8 9 10
146' -2"
TO ROOF
98' -0"
LEVEL 1 -SOUTH
108' -4"
LEVEL 2 -SOUTH
107' -1 1/8"
TOP LEVEL 1 -SOUTH
117' -2 7/8"
TOP LEVEL 2 -SOUTH
118' -5 3/4"
LEVEL 3 -SOUTH
127' -4 5/8"
TOP LEVEL 3 -SOUTH
128' -5 1/4"
ROOF -SOUTH
95' -0"
T.O. FOOTING17'-8 3/4"1'-0 5/8"8'-10 7/8"1'-2 7/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"3'-0"48'-2"UNIT ADDRESS IDENTIFICATION
PER IFC SECTION 505.1
BUILDING ADDRESS
SIGNAGE PER IFC 505.1.
MINIMUM 8" NUMERALS
ON CONTRASTING
BACKGROUND
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2 -NORTH
109' -1 1/8"
TOP LEVEL 1 -NORTH
119' -2 7/8"
TOP LEVEL 2 -NORTH
120' -5 3/4"
LEVEL 3
12345678910
129' -4 5/8"
TOP LEVEL 3 -NORTH
130' -5 1/4"
ROOF -NORTH
146' -2"
TO ROOF
9'-1 1/8"1'-2 7/8"8'-10 7/8"1'-2 7/8"8'-10 7/8"1'-0 5/8"15'-8 3/4"46'-2"UNIT ADDRESS IDENTIFICATION
PER IFC SECTION 505.1
UNIT ADDRESS IDENTIFICATION
PER IFC SECTION 505.1
UNIT ADDRESS IDENTIFICATION
PER IFC SECTION 505.1
ABCDEGH
146' -2"
TO ROOF
98' -0"
LEVEL 1 -SOUTH
108' -4"
LEVEL 2 -SOUTH
107' -1 1/8"
TOP LEVEL 1 -SOUTH
117' -2 7/8"
TOP LEVEL 2 -SOUTH
118' -5 3/4"
LEVEL 3 -SOUTH
127' -4 5/8"
TOP LEVEL 3 -SOUTH
128' -5 1/4"
ROOF -SOUTH17'-8 3/4"1'-0 5/8"8'-10 7/8"1'-2 7/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"48'-2"GAS METER LOCATION,
RE: CIVIL
F
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2 -NORTH
109' -1 1/8"
TOP LEVEL 1 -NORTH
119' -2 7/8"
TOP LEVEL 2 -NORTH
120' -5 3/4"
LEVEL 3
A B C D E G H
129' -4 5/8"
TOP LEVEL 3 -NORTH
130' -5 1/4"
ROOF -NORTH
146' -2"
TO ROOF
99' -0"
LEVEL 1 -MIDDLEELECTRIC METER
LOCATION, RE: CIVIL 46'-2"1'-0 5/8"8'-10 7/8"1'-2 7/8"8'-10 7/8"1'-2 7/8"9'-1 1/8"F
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:19:38 PMA201C
BLDG C -ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 WEST ELEVATION
0 20
GRAPHIC SCALE
10
1" = 10'-0"2 EAST ELEVATION
BLDG C
KEY PLAN -306 IMPALA
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 NORTH ELEVATION
KEYNOTES
KEY
VALUE KEYNOTE TEXT
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
146' -2"
TO ROOF
98' -0"
LEVEL 1 -SOUTH
108' -4"
LEVEL 2 -SOUTH
107' -1 1/8"
TOP LEVEL 1 -SOUTH
117' -2 7/8"
TOP LEVEL 2 -SOUTH
118' -5 3/4"
LEVEL 3 -SOUTH
127' -4 5/8"
TOP LEVEL 3 -SOUTH
128' -5 1/4"
ROOF -SOUTH
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -LIGHT BROWN
COLOR 01 -SHERWIN WILLIAMS "GAUNTLET GRAY"
COLOR 02 -SHERWIN WILLIAMS "REQUISITE GRAY"
COLOR 03 -SHERWIN WILLIAMS "AESTHETIC WHITE"
COLOR 04 -SHERWIN WILLIAMS "MOODY BLUE"
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2 -NORTH
109' -1 1/8"
TOP LEVEL 1 -NORTH
119' -2 7/8"
TOP LEVEL 2 -NORTH
120' -5 3/4"
LEVEL 3
129' -4 5/8"
TOP LEVEL 3 -NORTH
130' -5 1/4"
ROOF -NORTH
146' -2"
TO ROOF
99' -0"
LEVEL 1 -MIDDLE
146' -2"
TO ROOF
98' -0"
LEVEL 1 -SOUTH
108' -4"
LEVEL 2 -SOUTH
107' -1 1/8"
TOP LEVEL 1 -SOUTH
117' -2 7/8"
TOP LEVEL 2 -SOUTH
118' -5 3/4"
LEVEL 3 -SOUTH
127' -4 5/8"
TOP LEVEL 3 -SOUTH
128' -5 1/4"
ROOF -SOUTH
100' -0"
LEVEL 1 -NORTH
110' -4"
LEVEL 2 -NORTH
109' -1 1/8"
TOP LEVEL 1 -NORTH
119' -2 7/8"
TOP LEVEL 2 -NORTH
120' -5 3/4"
LEVEL 3
129' -4 5/8"
TOP LEVEL 3 -NORTH
130' -5 1/4"
ROOF -NORTH
146' -2"
TO ROOF
99' -0"
LEVEL 1 -MIDDLE
95' -0"
T.O. FOOTING
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:BUILDING C2/21/2023 6:19:55 PMA202C
BLDG C -COLORED
ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 WEST ELEVATION
0 20
GRAPHIC SCALE
10
1" = 10'-0"2 EAST ELEVATION
1" = 10'-0"3 SOUTH ELEVATION
1" = 10'-0"4 NORTH ELEVATION
BLDG C
KEY PLAN -306 IMPALA
01 04/13/22 PDP
02 05/16/22 50% SD SET
03 06/08/22 PDP RD 2
04 07/27/22 PDP RD 3
05 10/19/22 PDP RD 4
06 01/11/23 FDP RD 1
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:20:46 PMA301C
BLDG C -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 WEST FACADE (OPEN SPACE)
2 EAST FACADE (IMPALA CIRCLE)
BUILDING ENTRIES
BUILDING ENTRY
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:21:37 PMA302C
BLDG C -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 SW CORNER
2 NE CORNER
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
WHWHWHWHF
E
D
C
B
A
1 3 4 5 62
A201D
1
A201D4
A201D
2
A201D 3
879 SF
UNIT TYPE - FLAT
2A-H1
U101
733 SF
UNIT TYPE - FLAT
1A
U104
732 SF
UNIT TYPE - FLAT
1A
U103
889 SF
UNIT TYPE - FLAT
2A
U102
107 SF
TRASH
111
14'-8 3/4"11'-2"13'-11 1/4"13'-11 1/4"14'-8 3/4"
362 SF
STAIR
S101
68'-6"6'-3"18'-2 3/4"10'-10 3/4"29'-1 1/2"6'-3"70'-9"116 SF
BIKE PARKING
113
PATIO PATIO
PATIO PATIO
1'-8 1/2"12'-6"1'-0"
4
A4313
A431
WATER ENTRY
112
F
E
D
C
B
A
1 3 4 5 62
A201D
1
A201D4
A201D
2
A201D 3
793 SF
UNIT TYPE - FLAT
1D
U201
70'-9"14'-8 3/4"11'-2"13'-11 1/4"13'-11 1/4"14'-8 3/4"6'-3"18'-2 3/4"10'-10 3/4"29'-1 1/2"6'-3"3:123:12140 SF
RESIDENT
STORAGE
211
889 SF
UNIT TYPE- FLAT
2A
U202
68'-6"
4
A4313
A4314:123:12
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:2/21/2023 6:38:34 PMA101D
BLDG D -FLOOR PLANS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS0 20
GRAPHIC SCALE
10
1" = 10'-0"1 LEVEL 1
1" = 10'-0"2 LEVEL 2
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
F
E
D
C
B
A
1 3 4 5 62
A201D
1
A201D4
A201D
2
A201D 3
6:12 6:12
3:123:126:12 6:126:126:126:126:12
6:12 6:123:12
6:126:12
6:126:124:1214'-8 3/4"11'-2"13'-11 1/4"13'-11 1/4"14'-8 3/4"6'-3"18'-2 3/4"10'-10 3/4"29'-1 1/2"6'-3"70'-9"68'-6"
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:38:34 PMA102D
BLDG D -ROOF PLAN
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 ROOF
0 20
GRAPHIC SCALE
10
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
1 3 4 5 6
128' -7"
LEVEL 4
5083' -0"
TO FOOTING
2
1'-0 5/8"9'-0 5/8"1'-1 1/8"9'-1 1/8"28'-7"BUILDING ADDRESS SIGNAGE
PER IFC SECTION 505.1.
MINIMUM 8" NUMERALS ON
CONTRASTING BACKGROUND
5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
F E D C B A
128' -7"
LEVEL 4
5083' -0"
TO FOOTING9'-1 1/8"1'-1 1/8"9'-0 5/8"1'-0 5/8"28'-7"5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
13456
128' -7"
LEVEL 4
5083' -0"
TO FOOTING
2
1'-0 5/8"9'-0 5/8"1'-1 1/8"9'-1 1/8"28'-7"5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
FEDCBA
128' -7"
LEVEL 4
5083' -0"
TO FOOTING1'-0 5/8"9'-0 5/8"1'-1 1/8"9'-1 1/8"31'-7"ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:38:40 PMA201D
BLDG D -ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"1 SOUTH ELEVATION (MULBERRY STREET)
1" = 10'-0"4 EAST ELEVATION
1" = 10'-0"2 NORTH ELEVATION
1" = 10'-0"3 WEST ELEVATION
0 20
GRAPHIC SCALE
10
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
FEDCBA
128' -7"
LEVEL 4
5083' -0"
TO FOOTING
5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
F E D C B A
128' -7"
LEVEL 4
5083' -0"
TO FOOTING
5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
13456
128' -7"
LEVEL 4
5083' -0"
TO FOOTING
2
5086' -0"
LEVEL 1
110' -2 1/4"
LEVEL 2
109' -1 1/8"
TOP LEVEL 1
119' -2 7/8"
TOP LEVEL 2
120' -3 1/2"
ROOF
1 3 4 5 6
128' -7"
LEVEL 4
5083' -0"
TO FOOTING
2
ELEVATION LEGEND
SMOOTH HORIZONTAL FIBER CEMENT LAP SIDING
SMOOTH FIBER CEMENT BOARD & BATTEN SIDING
ASPHALT SHINGLE ROOF
EXTERIOR COLORS
ROOFING -MEDIUM BROWN
COLOR 01-SHERWIN WILLIAMS "LAZY GRAY"
COLOR 02-SHERWIN WILLIAMS "SERIOUS GRAY"
COLOR 03-SHERWIN WILLIAMS "EXTRA WHITE"
COLOR 04-CUSTOM COLOR TO MATCH ADJACENT
BRICK STRUCTURE AT 2300 W MULBERRY
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:38:47 PMA202D
BLDG D -COLORED
ELEVATIONS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1" = 10'-0"3 WEST ELEVATION
1" = 10'-0"4 EAST ELEVATION
1" = 10'-0"2 NORTH ELEVATION
1" = 10'-0"1 SOUTH ELEVATION (MULBERRY STREET)
0 20
GRAPHIC SCALE
10
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:39:01 PMA301D
BLDG D -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 SOUTH FACADE (MULBERRY STREET)
2 NORTH FACADE
BUILDING ENTRY
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:39:46 PMA302D
BLDG D -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 EAST FACADE
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY:REVIEWED BY:
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3
3575 Ringsby Ct, Ste 300A
STUDIO ARCHITECTURE
Denver, CO 80216
theSTUDIOarchitecture.com
866.529.9130
COPYRIGHTPLOT DATE:C
STUDIO Project No:
Sheet Issue & Revision Log
It is the client's responsibility prior to or during construction to notify the architect in
writing of any perceived errors or omissions in the plans and specifications of
which a contractor thoroughly knowledgeable with the building codes and methods
of construction should reasonably be aware. Written instructions addressing such
perceived errors or omissions shall be received from the architect prior to the client
or client's subcontractors proceeding with the work. The client shall be responsible
for any defects in construction if these procedures are not followed.
No Date Description
FOR REFERENCE ONLY
DRAWN BY: REVIEWED BY:2/21/2023 6:40:49 PMA303D
BLDG D -3D VIEWS
21-017.00306 IMPALA DRIVEFORT COLLINS, COMD CRIMPALA RENOVATIONS1 ENTRY CORNER
2 BACK CORNER
01 01/11/23 FDP RD 1
03/22/23 PERMIT
Sheet Issue & Revision Log
No Date Description
01 01/11/23 FDP RD 1
02 02/22/23 FDP RD2
03 03/22/23 FDP RD 3