HomeMy WebLinkAbout1323 W PLUM ST WIRELESS TELECOMMUNICATION EQUIPMENT - BDR230002 - SUBMITTAL DOCUMENTS - ROUND 2 - RESPONSE TO STAFF REVIEW COMMENTS 4751 Fox St. Denver, CO 80216 Response to Comments for the Zoning Review of DISH Wireless Colocation To: Development Services, Zoning and Building Permitting City of Ft Collins From: Kenneth Trujillo Subject: DNDEN00178B DISH Wireless Rooftop Collocation Date: 3/31/2023 Location: 1323 W Plum St, Unit DISH Ft. Collins CO 80521 Back in March of 2022, WYCO and UCI2 hired independent contractor Mike Sharlow to complete this zoning permit on our behalf. However, Mike Sharlow is no longer working for us on this project. I, Kenneth Trujillo, of UCI2 will be the main poiunt of contact moving forward. WYCO/UCI2 received the below planning comments from Ft Collins. Below are the City of Ft. Collins reviewer’s comments in black. Also below are WYCO/UCI2’s responses to these comments in Red. Department: Planning Services Contact: Jill Baty, jbaty@fcgov.com Topic: General Comment Number: 1 02/27/2023: FOR APPROVAL: Please move your antennas to the interior of the rooftop, rather than being mounted on the sides of the building, per Section 3.8.13(C)3 of the Land Use Code. The proposed antennas will be visible to neighbors living at eye level directly across Plum St. Through the parking lots to the south, they will be visible from Elizabeth St. In order to build a case for mounting antennas on the sides of the building, please submit the following: A propagation analysis showing the difference in coverage via wall mounting and roof mounting, WYCO/UCI2 has submitted a new propagation map showing the difference in coverage from mounting in the middle of the roof vs mounting to the sides of the building. In the Radio Frequency study, DISH’s radio frequency engineers found that the coverage almost doubles in range when mounted to the sides of the building (shown below in green) than compared to when they are mounted in the middle of the building (shown in orange). Visual simulations showing how the building would look with wall mounted and roof mounted antennas, We have revised our photo simulations to show the flush mounted antennas vs sled mounted antennas. An RF report showing RF radiation impacts to this and surrounding properties, The radio frequency propagation maps show the surrounding properties that will be covered by the new high speed internet and phone services provided by DISH Wireless’ deployment. Standards require that building mounted antennas are flush mounted. It appears that the plan proposes a wall mount with a 12 inch stand off. Please revise to use flush mount hardware, The antennas are tilted to cover the max area to the South. The 12” standoff is needed to allow the antennas to achieve these angles without the antennas hitting the wall. They will be installed as close to the wall as technically feasible. A photo simulation showing the antenna proposed for the north, Plu m facing side of the building using materials that match that part of the building (i.e., gray, not beige), and relocating the antenna as close as possible to the exterior corner of the stairwell (rather than centered on the stairwell as proposed), Both photos have been updated to show gray antennas. An alternate photo sim has been provided to show the antenna closer to the corner of the staircase. Details on where cables will be routed to the antennas. We would want to ensure that cable bundles are not going to protrude over the parapet or otherwise reach the antennas in a way that would draw attention to the overall installation. We will be drilling holes behind the antennas and installing our radios in the stairwell. Dish Wireless Site Address: 1323 W Plum St. Fort Collins, CO Dish Wireless Site Number: DNDEN00178B Alternate location closer to corner We will route the cables through the staircases to minimize the outside visual impact. Antennas outside Antennas outside Cabling Comment Number: 2 02/27/2023: FOR INFORMATION: Rooftop equipment that is not visible from the street or surrounding area does not need to be screened. The rooftop equipment will not be visible from the street or surrounding area. Respectfully, Kenneth Trujillo Site Acquisitions / Project Manager 4751 Fox St. Denver, CO 80216 719-205-9370 / Ken@uci2.net