Loading...
HomeMy WebLinkAboutTRIPLE CROWN SPORTS EXPANSION - MA220144 - SUBMITTAL DOCUMENTS - ROUND 3 - PHOTOMETRIC PLANPROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO LighƟng System Pole / Fixture Summary Pole ID Pole Height Mtg Height Fixture Qty Luminaire Type Load Circuit A1-A2 60'60'4 TLC-LED-1200 4.68 kW A 16'2 TLC-BT-575 1.15 kW A A3-A4 60'60'4 TLC-LED-1200 4.68 kW B 16'2 TLC-BT-575 1.15 kW B B1 60'60'7 TLC-LED-1500 10.01 kW A 50'1 TLC-LED-1500 1.43 kW A 16'2 TLC-BT-575 1.15 kW A B2 60'60'1 TLC-LED-1200 1.17 kW A 60'6 TLC-LED-1500 8.58 kW A 16'2 TLC-BT-575 1.15 kW A B3-B4 60'60'7 TLC-LED-1500 10.01 kW B 16'2 TLC-BT-575 1.15 kW B C1 60'60'6 TLC-LED-1500 8.58 kW A 16'3 TLC-BT-575 1.73 kW A C2 60'60'6 TLC-LED-1500 8.58 kW B 16'3 TLC-BT-575 1.73 kW B P1-P2 50'50'1 TLC-LED-1500 1.43 kW C 50'1 TLC-LED-600 0.58 kW C 50'2 TLC-LED-900 1.78 kW C 12 87 97.32 kW Circuit Summary Circuit Description Load Fixture Qty A Stadium 45.46 kW 40 B East Field 44.29 kW 39 C Warmup/Cages 7.58 kW 8 Fixture Type Summary Type Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-1500 LED 5700K - 75 CRI 1430W 160,000 >120,000 >120,000 >120,000 42 TLC-LED-600 LED 5700K - 75 CRI 580W 65,600 >120,000 >120,000 >120,000 2 TLC-LED-1200 LED 5700K - 75 CRI 1170W 136,000 >120,000 >120,000 >120,000 17 TLC-BT-575 LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 22 TLC-LED-900 LED 5700K - 75 CRI 890W 89,600 >120,000 >120,000 >120,000 4 Light Level Summary Calculation Grid Summary IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty Blanket Grid Horizontal 23.2 0 115 0.00 A,B,C 87 Blanket Grid Max Vert Illuminance (by Light Bank)26.9 0 142 0.00 A,B,C 87 Bleachers Horizontal Illuminance 46.2 20 72 3.53 2.31 A 40 Bullpens/Batting Cages Horizontal 33.9 14 47 3.41 2.42 C 8 Bullpen Horizontal 62.5 39 81 2.09 1.60 A 40 East Field (Infield)1st Base 72.4 24 113 4.80 3.02 B 39 East Field (Infield)3rd Base 77 31 122 3.91 2.48 B 39 East Field (Infield)High Home 75.2 34 117 3.46 2.21 B 39 East Field (Infield)Horizontal Illuminance 102 80 110 1.38 1.27 B 39 East Field (Outfield)1st Base 44.5 11 98 9.18 4.04 B 39 East Field (Outfield)3rd Base 45.7 11 104 9.05 4.16 B 39 East Field (Outfield)High Home 51.6 16 87 5.57 3.22 B 39 East Field (Outfield)Horizontal Illuminance 71.3 49 95 1.95 1.45 B 39 Stadium (Infield)1st Base 74.9 27 114 4.28 2.78 A 40 Stadium (Infield)3rd Base 74.9 27 112 4.11 2.77 A 40 Stadium (Infield)High Home 76.5 34 121 3.58 2.25 A 40 Stadium (Infield)Horizontal Illuminance 105 83 117 1.42 1.27 A 40 Stadium (Outfield)1st Base 45.9 10 97 9.64 4.59 A 40 Stadium (Outfield)3rd Base 45.8 15 97 6.49 3.05 A 40 PROJECT SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO Calculation Grid Summary IlluminationGrid Name Calculation Metric Ave Min Max Max/Min Ave/Min Circuits Fixture Qty Stadium (Outfield)High Home 52 16 85 5.26 3.25 A 40 Stadium (Outfield)Horizontal Illuminance 75.4 49 94 1.92 1.54 A 40 Warm Up Horizontal 16.8 5 30 6.16 3.35 C 8 ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 C1 A1 A2 B2 B1 96 103 94 105 107 88 86 82 89 82 105 108 109 112 105 90 76 70 77 78 53 99 111 116 111 98 82 71 66 70 67 49 114 117 113 106 92 74 67 67 69 65 49 116 108 103 99 83 69 68 76 80 76 53 83 90 91 84 74 72 77 90 94 86 80 82 78 79 75 76 82 85 84 71 75 81 81 81 77 81 81 73 82 86 93 72 72 76 77 74 86 81 74 59 50 55 63 64 59 35'45'159'159'45'35'23'119'119'45' SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A1-A2 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 C1 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 40 40 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Stadium Size: Irregular 207' / 220' / 184' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average:100 70 Scan Average:105.19 75.36 Maximum:117 94 Minimum:83 49 Avg / Min:1.27 1.54 Guaranteed Max / Min:1.5 2.5 Max / Min:1.42 1.92 UG (adjacent pts):1.19 1.48 CU:0.65 No. of Points:25 74 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 40 Total Load: 45.46 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 C1 A1 A2 B2 B1 60,-30,15 54 47 35 27 29 30 19 10 28 50 71 68 62 50 46 42 28 15 25 48 51 80 86 85 73 69 53 31 17 27 44 49 97 100 102 101 94 64 34 22 25 40 46 79 98 108 114 95 64 40 30 26 33 41 53 79 94 97 83 64 49 36 27 24 36 61 75 87 79 63 49 34 24 19 37 55 73 83 71 56 42 28 20 55 72 70 72 63 49 35 23 15 76 67 49 42 35 25 17 35'45'159'159'45'35'23'119'119'45' SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A1-A2 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 C1 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 40 40 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Stadium Size: Irregular 207' / 220' / 184' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED TV FOOTCANDLES: 1st Base InĮeld Ouƞield Guaranteed Average:70 40 Scan Average:74.93 45.88 Maximum:114 97 Minimum:27 10 Avg / Min:2.81 4.55 Max / Min:4.28 9.64 UG (adjacent pts):1.87 2.75 CU:0.65 No. of Points:25 74 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 40 Total Load: 45.46 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 C1 A1 A2 B2 B1 -30,60,15 55 69 78 102 93 64 47 48 65 81 48 68 87 106 109 93 72 61 71 88 72 36 62 87 105 112 97 81 70 73 77 65 27 50 72 96 104 88 75 67 64 62 52 29 46 65 84 84 68 62 57 51 47 38 30 41 48 55 53 49 53 48 41 35 19 27 28 29 31 37 41 36 30 25 18 17 17 23 28 30 31 26 21 37 35 30 30 30 28 25 19 15 52 43 33 29 23 19 17 35'45'159'159'45'35'23'119'119'45' SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A1-A2 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 C1 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 40 40 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Stadium Size: Irregular 207' / 220' / 184' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED TV FOOTCANDLES: 3rd Base InĮeld Ouƞield Guaranteed Average:70 40 Scan Average:74.91 45.79 Maximum:112 97 Minimum:27 15 Avg / Min:2.76 3.05 Max / Min:4.11 6.49 UG (adjacent pts):1.84 2.07 CU:0.65 No. of Points:25 74 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 40 Total Load: 45.46 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 C1 A1 A2 B2 B1 -40,-40,25 34 43 44 50 55 46 34 41 61 79 44 59 70 81 84 67 55 49 62 82 70 45 72 98 110 102 79 63 55 62 70 61 50 83 109 121 112 85 64 54 54 55 48 55 84 96 109 100 77 60 50 44 42 35 46 62 72 82 78 66 58 47 38 32 28 47 57 67 65 57 50 38 30 23 33 46 57 65 58 49 40 30 22 53 66 61 61 54 43 33 23 16 73 62 45 38 32 24 17 35'45'159'159'45'35'23'119'119'45' SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A1-A2 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 C1 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 40 40 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Stadium Size: Irregular 207' / 220' / 184' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED TV FOOTCANDLES: High Home InĮeld Ouƞield Guaranteed Average:70 40 Scan Average:76.47 52.00 Maximum:121 85 Minimum:34 16 Avg / Min:2.27 3.24 Max / Min:3.58 5.26 UG (adjacent pts):1.64 1.70 CU:0.65 No. of Points:25 74 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 40 Total Load: 45.46 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 A1 A2 B2 20 29 38 39 33 26 47 62 68 65 57 21 47 72 31 63 37 68 37 66 32 5935'45'45'35'23'119'119'SCALE IN FEET 1 : 30 0'30'60' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A1-A2 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 C1 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 40 40 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Bleachers Size: Irregular 207' / 220' / 184' Spacing: 10.0' x 10.0' Height: 11.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:46.23 Maximum:72 Minimum:20 Avg / Min:2.27 Max / Min:3.53 UG (adjacent pts):0.00 CU:0.02 No. of Points:22 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 40 Total Load: 45.46 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 A1 B1 39 63 69 61 43 54 78 81 67 46 58 76 79 70 51 35'45'119'45' SCALE IN FEET 1 : 30 0'30'60' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A1-A2 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 C1 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 40 40 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Bullpen Size: Irregular 207' / 220' / 184' Spacing: 10.0' x 10.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:62.47 Maximum:81 Minimum:39 Avg / Min:1.60 Max / Min:2.09 UG (adjacent pts):1.63 CU:0.02 No. of Points:15 LUMINAIRE INFORMATION Applied Circuits: A No. of Luminaires: 40 Total Load: 45.46 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 C1 A1 A2 B2 B1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 2 1 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 2 5 23 13 1 0 0 0 0 0 0 0 0 0 0 2 8 10 10 15 16 34 79 29 4 0 0 0 0 0 0 0 0 0 1 10 60 77 67 90 71 77 77 34 8 1 0 0 0 0 0 0 0 0 1 17 89 109 108 107 84 72 84 52 17 3 0 0 0 0 0 0 0 0 1 13 80 113 115 96 72 66 70 49 19 4 1 0 0 0 0 0 0 0 1 12 95 112 103 86 67 72 77 52 19 5 2 1 0 0 0 0 0 0 1 8 54 88 86 75 77 92 91 52 13 6 12 13 5 1 0 0 0 0 1 7 49 82 85 79 87 74 71 33 11 9 24 35 8 2 0 0 0 0 1 8 70 104 80 85 85 93 54 16 12 15 23 34 6 2 0 0 0 0 2 14 63 78 78 93 87 78 45 15 15 29 29 41 18 4 0 0 0 0 2 23 79 82 76 87 82 80 75 39 18 20 21 39 29 6 1 0 0 0 2 20 81 77 73 70 79 77 77 62 30 19 21 35 32 5 2 0 0 0 1 16 74 88 82 76 65 67 67 61 37 27 32 27 36 12 3 0 0 0 1 9 64 111 106 94 74 62 62 63 41 23 21 19 31 15 2 0 0 0 1 4 36 94 106 106 94 72 69 79 42 16 9 9 10 4 0 0 0 0 0 2 22 96 107 106 105 86 77 62 22 6 2 2 1 0 0 0 0 0 0 1 13 71 80 58 59 32 25 11 5 2 1 0 0 0 0 0 0 0 0 1 3 12 13 7 7 4 2 1 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35'45'159'159'45'35'23'119'119'45'71'410'292'149'325'280'150'185'41'267'23'348'153'393' A4 P1 P2 C2 B4 A3 B3 SCALE IN FEET 1 : 100 0'100'200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4A1-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 2 C1-C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 2 P1-P2 50'2'52' 52' 52' TLC-LED-900 TLC-LED-1500 TLC-LED-600 2 1* 1 2 1 1 0 0 0 12 TOTALS 87 87 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Blanket Grid Size: Irregular 207' / 220' / 184' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:23.15 Maximum:115 Minimum:0 Avg / Min:- Max / Min:- UG (adjacent pts):125.58 CU:0.89 No. of Points:460 LUMINAIRE INFORMATION Applied Circuits: A, B, C No. of Luminaires: 87 Total Load: 97.32 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 C1 A1 A2 B2 B1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 3 3 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 2 3 7 37 27 3 0 0 0 0 0 0 0 0 0 1 3 9 11 12 16 16 36 106 52 9 1 0 0 0 0 0 0 0 0 2 12 50 74 68 89 72 83 97 55 17 3 1 0 0 0 0 0 0 0 2 18 82 90 115 127 97 94 119 87 35 8 1 0 0 0 0 0 0 0 1 15 75 112 131 131 98 89 96 74 34 10 2 0 0 0 0 0 0 0 2 11 85 126 137 114 79 78 96 66 28 8 4 3 0 0 0 0 0 0 1 8 46 95 109 93 72 109 114 68 19 7 17 20 8 2 1 0 0 0 1 7 50 95 113 88 93 77 77 38 13 10 27 41 13 4 1 0 0 0 2 7 71 119 95 82 89 93 55 18 15 18 23 35 8 4 1 0 0 1 3 16 51 65 67 110 97 77 46 17 21 41 33 44 18 7 1 0 0 1 3 28 98 111 90 103 93 85 79 43 17 28 25 36 28 10 2 0 0 0 3 21 90 101 98 72 93 89 92 77 34 19 23 35 34 8 3 1 0 0 2 16 75 101 112 102 68 73 77 68 45 30 41 27 38 17 5 1 0 0 1 10 64 118 142 124 107 82 86 97 68 27 27 22 37 22 4 0 0 0 1 6 39 97 114 129 128 93 94 116 70 25 13 13 16 8 0 0 0 0 1 2 23 92 88 111 110 91 86 76 32 9 4 4 3 0 0 0 0 0 0 2 14 58 76 60 62 30 25 13 7 2 1 1 0 0 0 0 0 0 0 1 4 13 14 9 8 5 3 2 1 1 0 0 0 0 0 0 0 0 0 0 1 2 2 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35'45'159'159'45'35'23'119'119'45'71'410'292'149'325'280'150'185'41'267'23'348'153'393' A4 P1 P2 C2 B4 A3 B3 SCALE IN FEET 1 : 100 0'100'200' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS4A1-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 2 7 0 0 0 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 2 6 0 0 0 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 2 C1-C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 2 P1-P2 50'2'52' 52' 52' TLC-LED-900 TLC-LED-1500 TLC-LED-600 2 1* 1 2 1 1 0 0 0 12 TOTALS 87 87 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Blanket Grid Size: Irregular 207' / 220' / 184' Spacing: 30.0' x 30.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED MAX VERTICAL FOOTCANDLES EnƟre Grid Scan Average:26.93 Maximum:142 Minimum:0 Avg / Min:- Max / Min:- UG (adjacent pts):106.81 CU:0.89 No. of Points:460 LUMINAIRE INFORMATION Applied Circuits: A, B, C No. of Luminaires: 87 Total Load: 97.32 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 9610491103 108 9388869267 103106102 110 1109579778467 96106 1101051038576747459 107 110105100907771696954 1071059789807168707358 90908070666775787759 867466626270797465 796861606575737067 797465626878728171 7674656169737063 5149495154 45'35' 159'159' 119'45' 35'45' 45'119' A4 C2 B4 A3 B3 SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A3-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 39 39 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: East Field Size: Irregular 192' / 220' / 207' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES InĮeld Ouƞield Guaranteed Average:100 70 Scan Average:101.62 71.27 Maximum:110 95 Minimum:80 49 Avg / Min:1.28 1.47 Guaranteed Max / Min:2 2.5 Max / Min:1.38 1.95 UG (adjacent pts):1.14 1.45 CU:0.64 No. of Points:25 75 LUMINAIRE INFORMATION Applied Circuits: B No. of Luminaires: 39 Total Load: 44.29 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 60,-30,15 53453324262819112841 67645646423927152642 78828267624829162639 101 1029994815630202434 92109113105 865531232327 66959888694934252219 507379735948362520 486268645445342317 607173635140302115 7685806550382718 7270584433 45'35' 159'159' 119'45' 35'45' 45'119' A4 C2 B4 A3 B3 SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A3-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 39 39 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: East Field Size: Irregular 192' / 220' / 207' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED TV FOOTCANDLES: 1st Base InĮeld Ouƞield Guaranteed Average:70 40 Scan Average:72.40 44.49 Maximum:113 98 Minimum:24 11 Avg / Min:3.06 4.18 Max / Min:4.80 9.18 UG (adjacent pts):1.93 2.63 CU:0.64 No. of Points:25 75 LUMINAIRE INFORMATION Applied Circuits: B No. of Luminaires: 39 Total Load: 44.29 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 -30,60,15 567178102 936549496665 507286107 1159874657574 416685103122104 86777769 31527297109 9782716656 31476585907867565144 31435058595752443931 213032323641393328 111719222731292420 262627252626231815 4747454033262018 4949474338 45'35' 159'159' 119'45' 35'45' 45'119' A4 C2 B4 A3 B3 SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A3-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 39 39 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: East Field Size: Irregular 192' / 220' / 207' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED TV FOOTCANDLES: 3rd Base InĮeld Ouƞield Guaranteed Average:70 40 Scan Average:77.01 45.71 Maximum:122 104 Minimum:31 11 Avg / Min:2.48 3.99 Max / Min:3.91 9.05 UG (adjacent pts):1.66 2.28 CU:0.64 No. of Points:25 75 LUMINAIRE INFORMATION Applied Circuits: B No. of Luminaires: 39 Total Load: 44.29 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 -40,-40,25 34434246524535426264 44596675816855526669 4771931011028165596462 5281105117110 8766565550 5685102111 103 7858474338 48708084756249393428 365663615650423226 425155534742342620 566262534437292116 7479735744352517 6965534030 45'35' 159'159' 119'45' 35'45' 45'119' A4 C2 B4 A3 B3 SCALE IN FEET 1 : 40 0'40'80' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2A3-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 2 4 0 0 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 7 0 0 1 C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 3 6 0 0 5 TOTALS 39 39 0 Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: East Field Size: Irregular 192' / 220' / 207' Spacing: 20.0' x 20.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED TV FOOTCANDLES: High Home InĮeld Ouƞield Guaranteed Average:70 40 Scan Average:75.20 51.56 Maximum:117 87 Minimum:34 16 Avg / Min:2.22 3.30 Max / Min:3.46 5.57 UG (adjacent pts):1.64 1.60 CU:0.64 No. of Points:25 75 LUMINAIRE INFORMATION Applied Circuits: B No. of Luminaires: 39 Total Load: 44.29 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 56898877667788 7912131212119889101212 1013171818161412111112141617 1317222525221814131416182123 1419263030262117151618222728 1519252930262118171720242829 1518242827232119181820232728 165'305' 30'310' P1 P2 SCALE IN FEET 1 : 30 0'30'60' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2P1-P2 50'2'52' 52' 52' TLC-LED-900 TLC-LED-1500 TLC-LED-600 2 1* 1 2 1 1 0 0 0 2 TOTALS 8 8 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name: Warm Up Size: Irregular 192' / 220' / 207' Spacing: 10.0' x 10.0' Height: 3.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:16.76 Maximum:30 Minimum:5 Avg / Min:3.43 Max / Min:6.16 UG (adjacent pts):1.51 CU:0.21 No. of Points:98 LUMINAIRE INFORMATION Applied Circuits: C No. of Luminaires: 8 Total Load: 7.58 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. ILLUMINATION SUMMARY Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 172435454741424642393736373941444741404543332316 142028384235323130313231313331293131344037281914 165'305' 30'310'P1 P2 SCALE IN FEET 1 : 30 0'30'60' EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE THIS GRID OTHER GRIDS2P1-P2 50'2'52' 52' 52' TLC-LED-900 TLC-LED-1500 TLC-LED-600 2 1* 1 2 1 1 0 0 0 2 TOTALS 8 8 0 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO GRID SUMMARY Name:Bullpens/Baƫng Cages Size: Irregular 192' / 220' / 207' Spacing: 10.0' x 10.0' Height: 7.0' above grade ILLUMINATION SUMMARY MAINTAINED HORIZONTAL FOOTCANDLES EnƟre Grid Scan Average:33.88 Maximum:47 Minimum:14 Avg / Min:2.45 Max / Min:3.41 UG (adjacent pts):1.52 CU:0.21 No. of Points:48 LUMINAIRE INFORMATION Applied Circuits: C No. of Luminaires: 8 Total Load: 7.58 kW Guaranteed Performance:The ILLUMINATION described above is guaranteed per your Musco Warranty document and includes a 0.95 dirt depreciaƟon factor. Field Measurements:Individual Įeld measurements may vary from computer-calculated predicƟons and should be taken in accordance with IESNA RP-6-15. Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LAYOUT Not to be reproduced in whole or part without the written consent of Musco Sports Lighting, LLC. ©1981, 2022 Musco Sports Lighting, LLC.ENGINEERED DESIGN By: KDunkin · File #222610C · 02-Nov-22 Stadium Irregular C1 A1 A2 B2 B1 East Field Irregular A4 P1 P2 C2 B4 A3 B3 SCALE IN FEET 1 : 60 0'60'120' Pole locaƟon(s)dimensions are relaƟve to 0,0 reference point(s) Triple Crown SoŌball Fields 1 & 2 Fort Collins,CO EQUIPMENT LAYOUT INCLUDES: · East Field · Stadium Electrical System Requirements:Refer to Amperage Draw Chart and/or the "Musco Control System Summary" for electrical sizing. InstallaƟon Requirements:Results assume ± 3% nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locaƟons. EQUIPMENT LIST FOR AREAS SHOWN Pole Luminaires QTY LOCATION SIZE GRADE ELEVATION MOUNTING HEIGHT LUMINAIRE TYPE QTY / POLE 4 A1-A4 60'-15.5' 60' TLC-BT-575 TLC-LED-1200 2 4 1 B1 60'-50' 15.5' 60' TLC-LED-1500 TLC-BT-575 TLC-LED-1500 1 2 7 1 B2 60'-60' 15.5' 60' TLC-LED-1200 TLC-BT-575 TLC-LED-1500 1 2 6 1 B3 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 1 B4 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 2 7 2 C1-C2 60'-15.5' 60' TLC-BT-575 TLC-LED-1500 3 6 2 P1-P2 50'2'52' 52' 52' TLC-LED-900 TLC-LED-1500 TLC-LED-600 2 1* 1 12 TOTALS 87 * This structure uƟlizes a back-to-back mounƟng conĮguraƟon SINGLE LUMINAIRE AMPERAGE DRAW CHART Ballast SpeciĮcaƟons (.90 min power factor) Line Amperage Per Luminaire (max draw) Single Phase Voltage 208 (60) 220 (60) 240 (60) 277 (60) 347 (60) 380 (60) 480 (60) TLC-LED-1500 8.5 8.1 7.4 6.4 5.1 4.7 3.7 TLC-LED-600 3.4 3.2 3.0 2.6 2.0 1.9 1.5 TLC-LED-1200 7.0 6.6 6.1 5.2 4.2 4.0 3.0 TLC-BT-575 3.4 3.2 2.9 2.5 2.0 1.8 1.5 TLC-LED-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3