THE FLATS AT HANSEN FARM - FDP230004 - SUBMITTAL DOCUMENTS - ROUND 2 - SUPPLEMENTAL INFORMATION
NEW PAD MOUNTED UTILITYTRANSFORMER 120/208V, 3ØMAIN SWITCHBOARD (MSB-A):1200A, 120/208V, 3Ø, 4W, 65kAIC,NEMA-3R600A/3P600A JJN600A/3P600A JJNMMMMMMMMMMMMNG200A/3P200A JJNPANELHOUSE"LA"TLOADCENTERMETER CENTER-1 (MC-A1):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3RMETER CENTER-2 (MC-A2):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3R1600A400A/3P250A JJNPANELEVC"EVA"MNO SCALEUTILITYMETERG12LTGCONTROL31200S/4200/4250/4400/4600/4x1x3x4x7x5x6x2MUTILITYMETER5(TYPICAL)NEW PAD MOUNTED UTILITYTRANSFORMER 120/208V, 3ØMAIN SWITCHBOARD (MSB-B):2000A, 120/208V, 3Ø, 4W, 65kAIC,NEMA-3R600A/3P600A JJN600A/3P600A JJNMMMMMMMMMMMMMMMMMMMMNG600A/3P600A JJNPANELHOUSE"LB"TLOADCENTERMETER CENTER-1 (MC-B1):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3RMETER CENTER-2 (MC-B2):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3R2000A400A/3P400A JJNPANELEVC"EVB"NO SCALEG12LTGCONTROL32000S/4600/4400/4x1x3x4x7x5x6x2MUTILITYMETER5(TYPICAL)NO SCALENO SCALEMUTILITYMETERCH1PANELCT-CABINET600AMCB150/3POOLPANELSPD400/3CH2PANELNEW PAD MOUNTED UTILITYTRANSFORMER 120/208V, 3ØTNGG1LTGCONTROL31150/4400/4x1x2x3x4ONE-LINE DETAIL NOTES1SURGE PROTECTION DEVICE. PROVIDE CIRCUIT BREAKER,SIZE AS RECOMMENDED BY SUPPLIER.2TYPICAL DWELLING UNIT LOAD CENTER.ONE & TWO BEDROOM UNITS: 125A, 120/208V, 1-PHASETHREE BEDROOM UNITS: 150A, 120/208V, 1-PHASE3PROVIDE LIGHTING CONTROL PANEL, ACUITY CONTROLS BLUEBOX LED GR1408 LTD ENC SC SM NE1 GR1408 LTD INT 8FCDIDIM DTC DV FOR BUILDING EXTERIOR LIGHTING CONTROL.PANEL SHALL HAVE DIMMING MODULES FOR CONTROL OFEXTERIOR LIGHT FIXTURES. MODULES SHALL BE SUITABLEFOR LED, 0-10V, ELV, MLV AND FLUORESCENT LIGHTFIXTURES. LCP SHALL HAVE PHOTOCELL AND ASTRONOMICTIMECLOCK CONTROL.4PROVIDE A #6AWG COPPER GROUNDING ELECTRODECONDUCTOR FROM THE GARAGE PANEL TO A DRIVENCOPPER GROUND ROD.5PROVIDE 125A/2P CIRCUIT BREAKER FOR ALL (1) AND (2)BEDROOM UNITS, AND A 150A2P CIRCUIT BREAKER FOR ALL(3) BEDROOM UNITS.6PANEL SHALL BE PROVIDED WITH METERING BREAKERS ASREQUIRED TO COMPLY WITH 2021 IECC C405.12. HVAC LOADS,INTERIOR LIGHTING, EXTERIOR LIGHTING, PLUG LOADS,PROCESS LOADS, AND REMAINING LOADS SHALL BESEPARATELY METERED AND METER DATA SHALL BEACQUIRED AND STORED IN COMPLIANCE WITH IECC C405.12.5.BASIS OF DESIGN IS SIEMENS SEM3 SERIES METERINGSYSTEM.1.PROVIDE SLEEVES AS REQUIRED FOR VERTICAL ROUTING OFFEEDERS. RACEWAYS ON LEVELS ABOVE GROUND LEVELSHALL BE CONCEALED. ROUTE THROUGH WALLS ASREQUIRED. COORDINATE SLEEVE LOCATIONS AND RACEWAYROUTING WITH STRUCTURAL ENGINEER AND GENERALCONTRACTOR PRIOR TO ROUGH-IN.2.MAINTAIN FIRE RATING OF ALL PENETRATIONS.3.ELECTRICAL EQUIPMENT MUST FIT IN THE SPACE PROVIDEDWHILE MAINTAINING ALL CLEARANCE AND WORKING SPACEREQUIREMENTS.4.ALUMINUM ALLOY CONDUCTORS SHALL BE PERMITTEDWHERE ALLOWED BY THE NEC EXCEPT TO ROTATINGEQUIPMENT INCLUDING MECHANICAL EQUIPMENT ANDELEVATORS.5.ALUMINUM BUSSING IS PERMITTED IN ALL ELECTRICALEQUIPMENT.6.APPLICABLE OVERCURRENT PROTECTION DEVICES SHALLCOMPLY WITH ARC ENERGY REDUCTION REQUIREMENTS OFNEC 240.87.GENERAL NOTESG1GROUNDING ELECTRODE SYSTEM/CONDUCTORS SHALL BEINSTALLED PER NATIONAL ELECTRICAL CODE (NEC) ARTICLE 250REQUIREMENTS. REFER TO SPECIFICATIONS FOR ADDITIONALREQUIREMENTS.ALL GROUNDING ELECTRODES THAT ARE PRESENT AT EACHSTRUCTURE SHALL BE BONDED TOGETHER TO FORM THEGROUNDING ELECTRODE SYSTEM.1.PROVIDE MAIN BONDING JUMPER AND SUPPLY SIDEBONDING JUMPER WITHIN THE WIREWAY.2.PROVIDE A 3/0 COPPER GROUNDING ELECTRODE FROM THEELECTRICAL GROUNDING POINT TO THE MAIN METALUNDERGROUND WATER PIPE. MAIN WATER PIPE MUST BEIN DIRECT CONTACT WITH THE EARTH FOR 10 FEET ORMORE AND ELECTRICALLY CONTINUOUS. CONDUCTORSHALL BE THE SIZE CALLED FOR ON THE ELECTRICALONE-LINE AND FEEDER SCHEDULE. IF THE WATER PIPE ISOF THE DUCTILE TYPE OR NON-ELECTRICALLYCONTINUOUS, IT MUST BE MADE CONTINUOUS BY BONDINGAROUND INSULATED PORTIONS OF THE PIPE.3.PROVIDE A #6AWG COPPER GROUNDING ELECTRODECONDUCTOR FROM THE ELECTRICAL GROUNDING POINT TOA GROUND ROD.4.PROVIDE A #4AWG COPPER GROUNDING ELECTRODE FROMTHE ELECTRICAL GROUNDING POINT TO A CONCRETEENCASED ELECTRODE.GROUNDING ELECTRODESYSTEM NOTESFEEDER SCHEDULE ALUMINUM3000/W2000/W1600/W1200/W1000/W800/W750/W600/W500/W400/W350/W300/W250/W225/W200/W175/W150/W125/W100/W90/W80/W70/W60/W50/W40/WTHIS TABLE INDICATES MINIMUM CONDUCTOR SIZEFOR FEEDERS OF THE AMPACITY INDICATEDWHERE #/W INDICATES THE #-AMPACITY ANDW-NUMBERS OF WIRE, #S/W INDICATES NOGROUND. ALL CONDUCTORS SHALL BE ALUMINUMUNLESS NOTED OTHERWISE.*CONDUCTOR AMPACITIES SHALL BE BASED ONTABLE 310.15(B)(16) 60 DEGREE COLUMN UP TO100 AMPS AND 75 DEGREE COLUMN ABOVE 100AMPS UNLESS OTHERWISE PERMITTED BY NEC.AMPACITY RATING SHALL BE SELECTED INACCORDANCE WITH NEC 110.14 (C).THE MASTER ELECTRICIAN SHALL BE RESPONSIBLEFOR ENSURING THAT NO FEEDERS OR BRANCHCIRCUITS ARE INSTALLED IN A MANNER OR SIZEDIN SUCH A WAY AS TO VIOLATE NECSERVICEGROUNDTABLE150G/CU #6200G/CU #4300G/CU 2500G/CU 1/01000G/CU 2/0>1000G/CU 3/0SERVICE GROUND CONDUCTORS SIZED PER NECTABLE 250.66 EQUIPMENT GROUND CONDUCTORSSIZED PER NEC TABLE 250.122 ALL CONDUCTORSSHALL BE ALUMINUM UNLESS NOTED OTHERWISETHE SERVICE GROUND CHART INDICATES THEMINIMUM SERVICE GROUND CONDUCTOR BASEDON #G WHERE # IS THE AMPACITY FROM THECHART ABOVE, AND THE EQUIPMENT GROUNDCHART INDICATES THE MINIMUM EQUIPMENTGROUNDING CONDUCTOR SIZE #EG WHERE # ISTHE RATING/SETTING OF THE OVERCURRENTDEVICE PROTECTING THE CONDUCTORSAND EQUIPMENTWHERE DISCREPANCIES OCCUR BETWEEN THEFEEDER SCHEDULE SCHEDULE AND THEGROUNDING TABLES, THE LARGER CONDUCTORSHALL BE USED UNLESS OTHERWISE PERMITTEDBY THE NEC.THE INSTALLATION SHALL MEET ALL NEC 250GROUNDING AND BONDING REQUIREMENTSINCLUDING 250.4 PATH FOR FAULT CURRENT.PROVIDE COMPLETE RACEWAY SYSTEMSMETALLICALLY JOINED, CONNECTED, ANDFITTINGS AS REQUIRED FOR ELECTRICALCONTINUITY PER NEC 300.108[W-700kcmil, 600kcmilG, 4"C]6[W-600kcmil, 400kcmilG, 3-1/2"C]5[W-600kcmil, 350kcmilG, 3-1/2"C]4[W-500kcmil, 250kcmilG, 3-1/2"C]4[W-350kcmil, 4/0G, 3"C]3[W-400kcmil, 3/0G, 3"C]3[W-350kcmil, 3/0G, 3"C]2[W-500kcmil, 2/0G, 3-1/2"C]2[W-350kcmil, 1/0G, 3"C]2[W-250kcmil, #1G, 3"C]2[W-4/0, #1G, 2-1/2"C]W-500kcmil, #2G, 3-1/2"CW-350kcmil, #2G, 3"CW-300kcmil, #2G, 3"CW-250kcmil, #4G, 3"CW- 4/0, #4G, 2-1/2"CW- 3/0, #4G, 2"CW- 2/0, #4G, 2"CW-1/0, #6G, 2"CW-1/0, #6G, 2"CW#1, #6G, 1-1/2"CW#2, #6G, 1-1/4"CW#2, #8G, 1-1/4"CW#4, #8G, 1-1/4"CW#6, #8G, 1"CEQUIPMENTGROUNDTABLE20EG #1060EG #8100EG #6200-1200A PER ABOVE1600EG 350KCMIL2000EG 400KCMIL2500/W7[W-700kcmil, 350kcmilG, 3-1/2"C]600A/3P600A JJNMMMMMMMMMETER CENTER-3 (MC-B3):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3Rx8600/4NO SCALESPD1SPD1SPD6SPD1SPD6SPD1MMMMMMMMMMMMMMMMMM600/4600/4MUTILITYMETERNEW PAD MOUNTED UTILITYTRANSFORMER 120/208V, 3ØMAIN SWITCHBOARD (MSB-C):2500A, 120/208V, 3Ø, 4W, 65kAIC,NEMA-3R600A/3P600A JJN600A/3P600A JJNMMMMMMMMNG600A/3P600A JJNPANELHOUSE"LC"TLOADCENTERMETER CENTER-1 (MC-C1):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3RMETER CENTER-2 (MC-C2):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3R2500A400A/3P400A JJNPANELEVC"EVC"G12LTGCONTROL32500S/4600/4400/4x1x3x4x7x5x6x2MUTILITYMETER5(TYPICAL)600A/3P600A JJNMETER CENTER-3 (MC-C3):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3Rx8600/4SPD1SPD6SPD1MMM600/4600/4MUTILITYMETER600A/3P600A JJN600/4MMMMMMMMMMMMMMMMMMMMMMMMMMMMMETER CENTER-4 (MC-C4):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3Rx9MMMMMMMMMMMMMNEW PAD MOUNTED UTILITYTRANSFORMER 120/208V, 3ØMAIN SWITCHBOARD (MSB-D):2000A, 120/208V, 3Ø, 4W, 65kAIC,NEMA-3R600A/3P600A JJN600A/3P600A JJNMMMMMMMMMMMMMMMMMMMMNG400A/3P400A JJNPANELHOUSE"LD"TLOADCENTERMETER CENTER-1 (MC-D1):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3RMETER CENTER-2 (MC-D2):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3R2000A400A/3P400A JJNPANELEVC"EVD"G12LTGCONTROL32000S/4400/4400/4x1x3x4x7x5x6x2MUTILITYMETER5(TYPICAL)600A/3P600A JJNMMMMMMMMMETER CENTER-3 (MC-D3):600A, 208V, 3PHASE IN,1PHASE OUT65kAIC, NEMA 3Rx8600/4SPD1SPD6SPD1MMMM600/4600/4MUTILITYMETERMMM1111666600/4LOAD CENTER FEEDERS - ALUMINUMAll conductors are based upon NEC Table 310.16, VDC - Stands for Voltage Drop Compensated125A/1Ø(75 DEG) 150A/1Ø(75 DEG) DISTANCE01501802252502900150190210240270300--------------------------150180225250290325150190210240270300345FTFTFTFTFTFTFTFTFTFTFTFTFTFEEDER3#2/0,1#4G. 3#3/0,1#2G. 3#4/0,1#2G. 3#250kcmil, 1#1G.3#300kcmil, 1#1/0G.3#350kcmil, 1#1/0G.3#3/0,1#4G. 3#4/0,1#2G. 3#250kcmil, 1#2G.3#300kcmil, 1#1G.3#350kcmil, 1#1G.3#400kcmil, 1#1G.3#500kcmil, 1#1G.ALALALALALALALALALALALALALCONDUITMCMCMCMC2 1/2"2 1/2"MCMCMC2 1/2"2 1/2"3"3"VDCVDCVDCVDCVDC VDCVDCVDCVDCVDCVDCJ:\2022\2022-012-00\Cad\Elec\E001.dwg JonK 03.15.23 1:14 pm ARCHITECT'S PROJECT NUMBERCOPYRIGHT © 2023 STUDIO PBA, INC / ALL RIGHTS RESERVEDSHEET NUMBERSHEET TITLECURRENT PHASEISSUE DATE12/14/2022 2:08:12 PM FLATS AT HANSEN FARMS FORT COLLINS, COAR210002100% DESIGNDEVELOPMENT3/16/2023No.DescriptionDateE001ELECTRICAL ONE-LINEDIAGRAMS