HomeMy WebLinkAboutFISCHER PROPERTIES - FDP230010 - DOCUMENT MARKUPS - ROUND 1 - UTILITY PLANS (2)WEST PROSPECT ROAD SOUTH SHIELDS STREET57' RIGHT-OF-WAY RESIDENTIAL LOCAL STREET (WITH PARKWAY)7' PARKING8.5' PARKWAY5' SIDEWALK9' UTILITY EASEMENT DRIVE-OVER CURB & GUTTER ℄ 4:1 MAX 30' - 15' -℄7' PARKING8.5' PARKWAY5' SIDEWALK9' UTILITY EASEMENT DRIVE-OVER CURB & GUTTER 4:1 MAX 15' -℄ 16' TRAVEL LANE C 100COVER SHEET 1 Original Field Survery: Northern Engineering Project No. 1382-001 Date: August 07,2017 OCTOBER 2022 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH Project Datum: NAVD88 Benchmark PAULUS On the East edge of a double manhole Type R Inlet, 15 feet South of a concrete multi-use trail tunnel, 7 feet West of top back of curb near the Southwest corner of Shields St. and Elizabeth St. Elevation: 5025.82 Benchmark CSU2 The mark is a standard brass Larimer County geodetic control disk set in 2002, in the campus of Colorado State University approx. 240.8 feet South from the center line of North Drive, 46.6 feet Northeast from the edge of CSU Lagoon, 33 feet Southwest from the center of the delivery road to the University Club and 1.1 feet Southwest from the edge of the sidewalk. Elevation: 5006.29 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (Prior City of Fort Collins datum) for their vertical datums. If NGVD29 unadjusted datum (Prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 = NAVD88 - 3.17' Basis of Bearings The East line of the Northeast Quarter of the Southeast Quarter of Section 15, Township 7 North, Range 69 West of the 6th P.M. as bearing South 00° 29' 40" West (assumed). PROJECT BENCHMARKS: FISCHER PROPERTIES PROJECT TEAM: OWNER/APPLICANT SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO FIELD SURVEY BY: TYPICAL SECTIONS 1 C 100 COVER SHEET 2 C 101 GENERAL & CONSTRUCTION NOTES 3 C 200 EXISTING CONDITIONS & DEMOLITION PLAN 4 C 300 CIVIL SITE PLAN UTILITY SHEETS 5 C 400 OVERALL UTILITY PLAN 6-7 C 401-C 402 UTILITY PLAN 8 C403 SANITARY LINE A PLAN & PROFILE GRADING SHEETS 9 C 500 OVERALL GRADING PLAN 10-11 C 501-C 502 GRADING PLAN ROADWAY SHEETS 12 C 600 LAKEWOOD DRIVE PLAN & PROFILE 13 C 601 WESTWARD DRIVE RIGHT FLOWLINE - PLAN & PROFILE 14 C 602 DEL MAR STREET RIGHT FLOWLINE - PLAN & PROFILE 15 C 603 DEL MAR STREET & LAKEWOOD DRIVE INTERSECTION DETAIL DRAINAGE SHEETS 16 C 700 HISTORIC DRAINAGE EXHIBIT 17 C 701 DRAINAGE EXHIBIT UTILITY PLANS FOR CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETAPPROVED: City Engineer:Approved Sheets Date Water & Wastewater Utility Approved Sheets Date Stormwater Utility Approved Sheets Date Park Planning and Development Approved Sheets Date Traffic Operations Approved Sheets Date Environmental Planner Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: PROJECT LOCATION Ripley Design, Inc. Russ Lee, President 419 Canyon Avenue, Suite 200 Fort Collins, CO. 80521 (970) 224-5828 Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N PLANNER/ LANDSCAPE ARCHITECT SITE ENGINEER SURVEYOR ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ Erik Fischer 125 S. Howes Street, Suite 900 Fort Collins, CO 80521 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 City of Fort Collins Construction Inspection Manager Ken Zetye kzetye@fcgov.com Additional Survery: Northern Engineering Project No. 1382-002 Date: March 23, 2022 /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XWS OWS OWS OWS OW SO WS OWS OELEC W D D D VAULT ELEC M C VAULT ELEC M M D D D C EC C CCCC VAULT ELEC C C C C HY DV.P. V.P.STS S SS S X 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS SS15" SSSTSTSTSTSTSTSTSTSTSTSTSTS T 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSSTGW XX X X X X X X X XXXXX XXXXXXE W W W W W CTVCTVW CTV CTVCTVCTVCTVGGGCTV CTV G G G G G GGGG E EEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X X X X X X X X X XX X X X X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV XXXXXX X X X X X X X X X G G GG G CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRR W VAULT CABLE C VAULT CABLE OHU OHU OHU OHU OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHUXXXXXXXXXXGGE E E CTV CTV CTV CTV CTV CTV CTV CTV CTV 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SSW W W W W WWWWWWWWWWWWW EE E E E E E G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOE EEGGGGGGGGW W W W FOEFOG G G E E E E FO FO FO E FO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E EEW ELEC WCS W W ELEC VAULT TELE ELEC W W M M M S W F.O. F.O. D D CSCS CABLE FO FO FOEXISTING FENCE TO BE REMOVED (TYP.) EXISTING GATE TO BE REMOVED (TYP.) EXISTING GATE TO BE REMOVED (TYP.) EXISTING TREE TO BE REMOVED (TYP.) EXISTING BUILDINGS TO BE REMOVED (TYP.) EXISTING SHRUB TO BE REMOVED (TYP.) ±400 LF EXISTING HOLLYWOOD CURB, GUTTER, & ATTACHED SIDEWALK TO BE REMOVED EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN EXISTING WATER SPIGOT TO BE REMOVED (TYP.) EXISTING GRAVEL DRIVE TO BE REMOVED (TYP.) EXISTING UTILITY POLE TO BE REMOVED (TYP.) EXISTING NATURAL GAS LINE TO BE REMOVED EXISTING WATER SERVICE TO BE REMOVED (TYP.) EXISTING NATURAL GAS LINE TO BE REMOVED ±279 LF EXISTING HOLLYWOOD CURB, GUTTER, & ATTACHED SIDEWALK TO BE REMOVED SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE EXISTING DRIVEWAY APPROACHES TO BE REMOVED EXISTING UTILITY EASEMENT TO BE VACATED (TYP.) EXISTING UTILITY EASEMENT TO BE VACATED (TYP.) EXISTING LOT LINE TO BE VACATED (TYP.) ±522 LF EXISTING 8" CLAY SANITARY SEWER TO BE ABANDONED IN PLACE EXISTING 8" CLAY SANITARY SEWER TO REMAIN EXISTING 6" CAST IRON WATER MAIN TO BE RELOCATED BY THE CITY OF FORT COLLINS EXISTING 6" CAST IRON WATER MAIN TO REMAIN EXISTING 15" PVC SANITARY SEWER TO REMAIN EXISTING 21" RCP STORM DRAIN TO REMAIN EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING 10" CLAY SANITARY SEWER EXISTING ELECTRIC EXISTING 6" CAST IRON WATER MAIN TO REMAIN EXISTING GAS LINE EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING STORM DRAIN EXISTING FENCE EXISTING 24" RCP STORM DRAIN TO REMAIN EXISTING 18" RCP STORM DRAIN TO REMAIN EXISTING 40' FL-FL EXISTING 60' ROW EXISTING ±64' FL-FL PROPOSED SAWCUT (TYP.) EXISTING 60' ROW TO BE VACATED PROPOSED SAWCUT (TYP.) EXISTING 6" CAST IRON WATER MAIN TO RELOCATED BY THE CITY OF FORT COLLINS EXISTING 8" CLAY SANITARY SEWER TO REMAIN EXISTING FIRE HYDRANT TO BE REMOVED BY OTHERS EXISTING ±39' FL-FL EXISTING 60' ROW EXISTING SECTION LINE EXISTING 3' ATTACHED SIDEWALK EXISTING HOLLYWOOD CURB, GUTTER, & WALK EXISTING 3' ATTACHED SIDEWALK EXISTING 6' ATTACHED SIDEWALK40' FL-FLOWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. LOT 17LOT 18LOT 19LOT 20LOT 21 LOT 39LOT 38LOT 37LOT 36LOT 34 LOT 35 LOT 40LOT 41LOT 42LOT 43 LOT 45 LOT 44 LOT 63LOT 62LOT 61LOT 60LOT 58 LOT 59 EXISTING WATER SERVICE TO BE REMOVED PROTECT EXISTING TREE IN PLACE PROTECT CRITICAL ROOT ZONE AS MUCH AS POSSIBLE. EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN (TYP.) EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN (TYP.) EXISTING SANITARY SEWER MANHOLE RIM=5038.44 INV IN=5030.84 (W) INV OUT=5030.69 (S) EXISTING SANITARY SEWER MANHOLE TO BE REMOVED RIM=5031.59 INV IN=5124.39 (E) INV IN=5124.4 (S) INV OUT=5124.39 (E) EXISTING SANITARY SEWER MANHOLE TO BE REMOVED RIM=5030.94 INV IN=5023.34 (N) INV OUT=5023.31 (S) EXISTING SANITARY SEWER MANHOLE RIM=5035.50 INV IN=5022.45 (N) INV IN=5026.44 (W) DROP INV OUT=5022.29 (E) EXISTING ±50' HALF ROW EXISTING "STOP" SIGN TO BE RELOCATED EXISTING "2-HOUR PARKING" SIGN TO BE RELOCATED EXISTING "2-HOUR PARKING" SIGN TO BE RELOCATED EXISTING "2-HOUR PARKING" SIGN TO BE RELOCATED EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN (TYP.) RELOCATE EXISTING ELECTRIC BOX AND CABLE PEDESTAL EXISTING MAILBOX TO BE REMOVED EXISTING MAILBOX TO BE REMOVED EXISTING "2-HOUR PARKING" SIGN TO BE REMOVED EXISTING 15" RCP STORM DRAIN TO REMAIN DEL MAR DEMOLITION AND PAVING TO BE COORDINATED WITH THE CITY OF FORT COLLINS WATER MAIN RELOCATION PROJECT WESTWARD DRIVE DEMOLITION AND PAVING TO BE COORDINATED WITH THE CITY OF FORT COLLINS WATER MAIN RELOCATION PROJECT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETEXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.ALL WATER AND SEWER SERVICES SHALL BE REMOVED AND ABANDONED AT THE CITY MAIN, PER FORT COLLINS UTILITIES STANDARDS. EXISTING OVERHEAD UTILITY OHE NORTHERN ENGINEERING PROJECT NO. 1382-001 DATE: AUGUST 07,2017 EXISTING SECTION LINE NORTHERN ENGINEERING PROJECT NO. 1382-002 DATE: MARCH 23, 2022 C 200DEMOLITION PLAN EXISTING CONDITIONS &3 X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D VAULT ELEC C VAULT ELEC D D D C EC C CCCC VAULT ELEC C C C C STS S SS S 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS SS15" SSSTSTSTSTSTSTSTSTSTSTSTSTS T 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSSTCTVCTVCTV CTVCTVCTVCTVGGGCTV CTV GGGGEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV VAULT CABLE VAULT CABLE OHU OHU OHU OHU OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SSWWWWWWWWWWWWW EE E E E E E G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOE EEGGGGGGGGW W W W FOEFOG G G E E E E FO FO FO E FO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E EEW ELEC WCS W VAULT TELE ELEC S W F.O. F.O. D D CABLE FO FO FOE E EEEEEEEEEEEEEEEEEEEEEET E E EEEFDCNYLOP L A S T DO NOT PO L L U T E DRAINS TOWATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UDUDUDUD UDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS W W W W W W W W W W W WWGAS ELEC E T DS DS FSWWWWWWWWWELECG GGGWNYLOP LA S T DO NOT PO L L UT E DRAINS TO WATERWA Y S DO NOT POLL U T E D R A I NS T O WA T E RW A Y S NYLOPLAST D UC T I L E IR O N NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS/ / / / / / / /PROPOSED 8" PVC SANITARY SEWER PROPOSED 6" WATER MAIN CONNECT TO RELOCATED WATER MAIN BY OTHERS CONNECT TO EXISTING 8" CLAY SANITARY SEWER RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 3 4" UNDERDRAIN 30' SANITARY SEWER EASEMENT PROPOSED STORM DRAIN PROPOSED STORM DRAINPROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 PROPOSED 8" SANITARY SERVICE PROPOSED 6" FIRE SERVICE PROPOSED 2" WATER METER PROPOSED FIRE HYDRANT CONNECT TO EXISTING STORM DRAIN 9' DRAINAGE & UTILITY EASEMENT 5' UTILITY EASEMENT SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE 30' FL-FL57' ROW 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED FIRE HYDRANT EXISTING ELECTRIC LINE EXISTING CABLE TV LINE PROPOSED 4' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN DETENTION POND 1 LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 BLOCK 1 BLOCK 1 TRACT B AE,DE,UE EXISTING 8" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER MAIN EXISTING 15" PVC SANITARY SEWER EXISTING 21" RCP STORM DRAIN EXISTING GAS LINE EXISTING 10" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER MAIN EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING 24" RCP STORM DRAIN EXISTING 18" RCP STORM DRAIN RELOCATED WATER MAIN BY OTHERS EXISTING 8" CLAY SANITARY SEWER PROPOSED 2' CONCRETE PAN PROPOSED ROOF DRAIN (TYP.) OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. APPROXIMATE LOCATION CONNECT TO EXISTING 3-PHASE POWER PROPOSED TRANSFORMER PROPOSED TRANSFORMER CONNECT TO EXISTING STORM INLET 30' SANITARY SEWER EASEMENT TRACT A AE,DE,UE PROPOSED FIRE HYDRANT PROPOSED IRRIGATION METER RELOCATED WATER BY OTHERS PROPOSED 8" PVC SANITARY SEWER CONNECT TO EXISTING 15" SANITARY SEWER WITH NEW MANHOLE EXISTING 15" RCP STORM DRAIN PROPOSED IRRIGATION METER PROPOSED INLET W PITKIN ST CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 C 400OVERALL UTILITY PLAN 5 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETKEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 X X X X X X X XXX X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXX CCCC VAULT ELEC C C C C CTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHUOHUOHU OHU 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSE E EEEEGGGGGGGGGGGGGGGGGGW FO FO FO S / / / / / / / // / / / / / / // / / / / / / /UDUDUDUDUDUDUDUDWWWWWWWWWWWWWWWWWWWPROPOSED 8" PVC SANITARY SEWER PROPOSED 6" PVC WATER MAIN CONNECT TO RELOCATED WATER MAIN BY OTHERS PROPOSED DETENTION POND 1 PROPOSED UNDERDRAIN 30' SANITARY SEWER EASEMENT PROPOSED FIRE HYDRANT 5' UTILITY EASEMENT 5' UTILITY EASEMENT DEL MAR STREETLAKEWOOD DRIVE30' FL-FL57' ROW PROPOSED FIRE HYDRANT LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT RAINGARDEN ABLOCK 1 BLOCK 1 PROPOSED 2' CONCRETE PAN 3' DRAINAGE EASEMENT (TYP.) PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE EXISTING ELECTRIC LINE EXISTING GAS LINE EXISTING 8" CLAY SANITARY SEWER OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. ±39' FL-FL 60' ROW 5' SLOPE EASEMENT TRACT A AE,DE,UE 30' SANITARY SEWER EASEMENT RELOCATED WATER MAIN BY OTHERS RAINGARDEN APROPOSED IRRIGATION METER CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 402C 401UTILITY PLAN 6 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETNOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 X X X X XXXXXX X X XXXXXXXXXXXXXXD D VAULT ELEC C VAULT ELEC D D C EC C C C S 8" SS 8" SS 8" SS SS STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSCTVCTVCTVCTVCTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV GGGGGGGEEEEEEEEEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVVAULT CABLE VAULT CABLE OHU OHU OHU OHUOHUOHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CT V CTV CTV CTV CTV CTV C T VWEEWE E E E E E E E E E E G G G G G G G G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E E E E E E EEEELEC WCS VAULT TELE ELEC FO FO FO FO FOFOE E E E E EEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEET E E E E E EEEEEEFDCNYLOPLASTDO NO T P O L L U T E DRAIN S T O WATE R W A Y S DO NOT P O L L U T E D R A I N S T O W A T E R W A Y S NYLOP L A S T D U C T I L E I R O N UDUDUD UD UD UD UD UD UD UD UD UD UDUDUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS W W W W W W W W W W W W W W W W W W W W W W WGAS ELEC EE E T DS DS FSELECG G G GGGGGGWNYLOPLAS T DO NOT PO LL UT E DRAINS TO WATE RWA YS DO NOT PO LL U TE D RA I NS TO WA TE RW A YS NYLOP L AS T D UC T I LE IR ON NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS PROPOSED DETENTION POND 1 PROPOSED DETENTION POND 1 30' SANITARY SEWER EASEMENT PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH CHAMBERS PROPOSED 8" SANITARY SERVICE PROPOSED 2" WATER METER CONNECT TO EXISTING STORM DRAIN SOUTH SHIELDS STREETWESTWARD DRIVE 6' SIDEWALKLOT 1 PROPOSED STORM DRAIN PROPOSED UNDERDRAIN PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE DRAINAGE EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT EXISTING 8" CLAY SANITARY SEWER EXISTING 15" PVC SANITARY SEWER EXISTING 21" RCP STORM DRAIN EXISTING GAS LINEEXISTING ELECTRIC LINE EXISTING 18" RCP STORM DRAIN OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. 26' EMERGENCY ACCESS EASEMENT PROPOSED ROOF DRAIN ±37' FL-FL 60' ROW PROPOSED TRANSFORMER APPROXIMATE LOCATION CONNECTION TO 3-PHASE POWER AT CORNER OF SPRINGFIELD DRIVE & SHIELDS STREET PROPOSED FDC DRAINAGE EASEMENT DRAIN BASIN w/ 100-YR WEIR DRAIN BASIN w/ WQ WEIR CONNECT TO EXISTING STORM INLETPROPOSED CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN ISOLATOR ROWS 30' SANITARY SEWER EASEMENT PROPOSED UNDERGROUND DETENTION POND 2 PROPOSED 6" FIRE SERVICE RELOCATED WATER MAIN BY OTHERS PROPOSED 8" PVC SANITARY SEWER CONNECT TO EXISTING 8" CLAY SANITARY SEWER PROPOSED FIRE HYDRANT PROPOSED IRRIGATION METER CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 401 C 402UTILITY PLAN 7 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETNOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 8.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 9.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 10.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 E E EEEEEEEEEEEEEEEEET E E EFDCNYLOPL A S T DO NOT POLL U T EDRAINS TOWATERWAYS DO NOT POLLUTE D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UD UDUD UDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS W W W W W W W W W WWGAS ELEC E T DS DS FSWWWWWELECG GGWNYLOPL A ST DO NOT POLL U T EDRAINS TOWATERWAYS DO NOT POLLUTE D R A IN S T O WA T E R W AY S NYLOPLAST D U C T I L E I R O N NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS X X X XXX X XXXXXD D VAULT ELEC CC CC C VAULT ELEC CC CC CC CC CC CC D D D C EC C VAULT ELEC C C C C SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS SS15" SSSTSTSTSTSTSTST15" SS15" SS15" SS15" SS15" SS15" SS15" SSCTVCTVCTV CTVCTVCTVGGCTV GGEEEEEECTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV VAULT CABLE VAULT CABLE OHUOHUOHU OHU OHU OHU OHU OHU OHU E E E CTV CTV CTV CTV CTV CTV CTV 8" SS 8" SS 8" SS8" SSWWWWWWWWWW W E E E E G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOEEGGGGGFO CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E EW ELEC WCS W VAULT TELE ELEC S D DFO FO/ / / / / / / /TRACT B AE,DE,UE TRACT A AE,DE,UE LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 SOUTH SHIELDS STREETWESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: CARLSON, BEVERLY A. PROPOSED 6" PVC WATER MAIN PROPOSED UNDERDRAIN 30.00' SANITARY SEWER EASEMENT 30' FL-FL57' ROW EXISTING GAS LINEEXISTING ELECTRIC LINE ±37' FL-FL60' ROWRELOCATED WATER MAIN BY OTHERS RELOCATED WATER MAIN BY OTHERS CONNECT TO EX. SANITARY MAIN WITH NEW MANHOLE SSMH A STA 10+00.00 N: 125466.89 E: 189477.46 325.28 LF 8" PVC @ 0.40% SSMH A1 STA 13+25.28 N: 125472.31 E: 189152.22 78.01 LF 8" PVC @ 0.40% SSMH A2 STA 14+03.28 N: 125495.09 E: 189077.62 189.11 LF 8" PVC @ 0.40%SSMH A3 STA 15+92.39 N: 125306.00 E: 189075.42 175. 5 0 L F 8" P V C @ - 0. 4 0 % SSMH A4 STA 17+67.89 N: 125220.19 E: 188922.34 250.08 LF 8" PVC @ 0.40% SSMH A5 STA 20+17.97 N: 125222.35 E: 188672.27 EX. 15" RCP STORM EX. 15" PVC SANITARY SEWER 30.00' SANITARY SEWER EASEMENT EXISTING 8" CLAY SANITARY SEWER SAWCUT (TYP.) 8" SANITARY SEWER SERVICE CONNECT TO EXISTING 8" CLAY SANITARY SEWER WITH DISSIMILAR PIPE COUPLING AND EXTEND AT SAME GRADE TO PROPOSED MANHOLE WITH 8" PVC ±21.94 LF 8" PVC APPROXIMATE LOCATION EXISTING SANITARY SEWER SERVICES. CONTRACTOR TO COORDINATE WITH THE CITY OF FORT COLLINS TO CONNECT EXISTING SERVICE TO PROPOSED MAIN AND ABANDON EXISTING MAIN. S S 5010 5015 5020 5025 5030 5035 5040 5045 5050 5010 5015 5020 5025 5030 5035 5040 5045 5050 9+5010+0011+0012+0013+0014+0015+0016+0017+0018+0019+0020+0021+00 SSMH ASTA 10+00.00RIM 5028.4±INV. IN 5020.23 (N)INV. IN 5020.43 (W)INV. OUT 5020.23 (S)325.28 LF 8" PVC @ 0.40%SSMH A1STA 13+25.28RIM 5030.2±INV. IN 5021.93 (W)INV. OUT 5021.73 (E)78.01 LF 8" PVC @ 0.40%SSMH A2 (EXTERNAL DROP)STA 14+03.28RIM 5031.1±INV. IN 5024.39 (W)INV. IN 5022.44 (S)INV. OUT 5022.24 (E)189.11 LF 8" PVC @ 0.40%SSMH A3STA 15+92.39RIM 5031.6±INV. OUT 5023.40 (SW)INV. OUT 5023.20 (N)175.50 LF 8" PVC @ -0.40%SSMH A4STA 17+67.89RIM 5032.2±INV. IN 5024.30 (W)INV. IN 5024.10 (NE)250.08 LF 8" PVC @ 0.40%SSMH A5STA 20+17.97RIM 5036.4±INV. OUT 5025.30 (E)EXISTING GROUND PROPOSED GROUND EX. 15" RCP STORM STA.=10+18.40 INV.=5025.31 APPROX. 8" PVC WATER (BY OTHERS) STA.=14+13.70 INV.=5025.53 28" APPROX. EX. WATER SERVICE STA.=12+72.72 INV.=5024.59 APPROX. EX. WATER SERVICE STA.=13+67.43 INV.=5025.52 4" HDPE SUBDRAIN STA.=17+06.53 INV.=5027.80 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETC403PLAN & PROFILESANITARY LINE A8 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 C403 PROFILE SCALE: SANITARY LINE A EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL SANITARY CONSTRUCTION SHALL BE (LOCAL ENGINEERING STANDARD), LATEST EDITION. 3.MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STROM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6.ALL SINGLE-FAMILY SANITARY SEWER SERVICES TO BE 4" PVC. 7.ALL SANITARY MANHOLES TO BE 4'Ø UNLESS NOTED OTHERWISE. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. W EXISTING STORM SEWER SPROPOSED SEWER SERVICE EXISTING SANITARY SEWER SS PROPOSED AREA STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY W EASEMENT LINE PROPOSED RIGHT OF WAY PROPOSED COMBO STORM INLET PROPOSED TYPE-R STORM INLET PROPOSED WATER SERVICE NYLOP L A S T DO NOT PO L L U T E DRAINS TOWATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UDUDUDUD UDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS W W W W W W W W W W W DS DSW WWWWWWWWNYLOP LA S T DO NOT PO L L UT E DRAINS TO WATERWA Y S DO NOT POLL U T E D R A I NS T O WA T E RW A Y S NYLOPLAST D UC T I L E IR O N NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D D D D STSTSTSTSTSTSTSTSTSTSTSTSTS T STD D / / / / / / / /SOUTH SHIELDS STREETSPRING F I E L D D R I V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE SIDEWALK SIDEWALK SIDEWALKSIDEWALK SIDEWALK SIDEWALK SIDEWALK30' FL-FL57' ROW RAIN GARDEN BIOMEDIA AREA DETENTION POND 3 DETENTION POND 1 SIDEWALKSIDEWALKPROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED AREA DRAIN PROPOSED STORM INLET PROPOSED CURB INLET 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 TRACT B AE,DE,UE EXISTING 18" STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' SIDEWALK CULVERT PROPOSED 4' SIDEWALK CULVERT PROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 FFE=32.92 OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. ± 37' FL-FL EXISTING 60' ROW EXISTING ±64' FL-FL ±40' FL-FL 60' ROW 40' FL-FLEXISTING ±50' HALF ROW PROPOSED MULTI-FAMILY BUILDING PROPOSED CURB INLET PROPOSED STORM DRAIN PROPOSED STORM INLET PROPOSED STORM INLET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 500OVERALL GRADING PLAN 9 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETPROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE C 502 C 501 X X X X X X X XXX X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXX/ / / / / / / // / / / / / / // / / / / / / /UDUDUDUDUDUDUDUDWWWWWWWWWWWWWWWWWW32.4136.6129.90 3 1 . 6 6 30.8930.9031.0931.2131.673 2 . 4 231.6731.79 31.6431.800.6% 2.4%2.5%0.5%0.2%2.9%DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 1.3% LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED DETENTION POND 3 RAINGARDEN A(35.22)(34.39)(33.70)32.56 33.7134.24 35.63 35.6334.2433.72 32.21 (35.24)(35.85)(36.59)(37.66)(38.85)31.37 31.34 31.43 BLOCK 1 BLOCK 1 RAIN GARDEN BIOMEDIA AREA PROPOSED 2' CONCRETE PAN 30' FL-FL57' ROW 30' SANITARY SEWER EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT 3' DRAINAGE EASEMENT (TYP.) PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE PROPOSED 4' SIDEWALK CULVERT 6" RIBBON CURB RAIN GARDEN BIOMEDIA AREA(36.33)(3 5 . 7 8 )(40.82)(35 . 0 1 )(33.39)(3 3 . 9 0 )31.9331.1331.6030.9731.4631.3931.2431.2931.45(33.35)(3 6 . 9 0 )37.0138.1637.5936.0735.5933.1133.7332.25 32.08 31.8232.9833.7338.0039. 0 9 29. 9 0 29.90 31.1726.8326.9926.8232.1932.1631.16 29.9029.9030.32 31.4529.9030.31RAINGARDEN A31.31OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. ±39' FL-FL 60' ROW 31. 0 8 32.3226.98 3 2 . 1 7 32.59 31.68 26.69 0.5%0.5% 26.88 0.6% PROPOSED 2' CURB CUT 1.0%3.5%0.5%0.5%0.5%2.0% 2.0%0.5%2.0%2.1%1.6%1.0%30.9831.7231.6231.9032.0032.0732.0331. 4 131.5031.88 31.7931.71 31.76 2.2%0.5% 0.5 % 2.6%0.6%31.500.5%31.35PROPOSED 2' CURB CUT 31.1132.01 31.5432.1731.54 32.01 30.48 31. 3 1 29. 9 0 29.9031.3127.51 27.51 32.02 31.95 33.26 29.20 28.64 27.59 27.7927.17 34.14 35.17 35.33 34.19 34.12 34.0433.75 27.06 27.00 26.92 27.13 SLOPE EASEMENT 31.813 2 . 0 132.103 2 . 0 0 32.0231.9731.8531.232.7%2.0%2.6%2.8%2.1% 2.1% 1.9%2.1%2.3%2.3%2.0% 2.2%2.5 % 2.5%2.7%2.6%1.6%5 : 1 6:1 4:14:16:15:14:1 4:1 4:1 4:1 4:1 4:1 4:16:16:131.291.0%6' SI D E W A L K 6' SIDEWALK TRACT A AE,DE,UE TRACT A AE,DE,UE 0.8% 0 . 6%0.5%2.4%2.1%1.1%31.46PROPOSED 2' SIDEWALK CULVERT 29.73 TOW 29.73 TOW 27.15 27.23 FG 27.24 FG LANDSCAPE RETAINING WALL RE: LANDSCAPE PLANS 26.7326.89 30.28 30.990.5% (32 . 2 7 ) POND 3 EMERGENCY OVERFLOW PATH POND 2 EMERGENCY OVERFLOW PATH PROPOSED INLET 100-YR WSEL 5031.31 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE SHEET C 502C 501GRADING PLAN 10 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETPROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA C 502 C 501 X X X X XXXXXX X X XXXXXXXXXXXXXXD D D D STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T FDCNYLOPLASTDO NO T P O L L U T E DRAIN S T O WATE R W A Y S DO NOT P O L L U T E D R A I N S T O W A T E R W A Y S NYLOP L A S T D U C T I L E I R O N UDUDUD UD UD UD UD UD UD UD UD UD UDUDUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS W W W W W W W W W W W W W W W W W W W W W W DS DS NYLOPLAS T DO NOT PO LL UT E DRAINS TO WATE RWA YS DO NOT PO LL U TE D RA I NS TO WA TE RW A YS NYLOP L AS T D UC T I LE IR ON NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS 31.6630.8930.9031.0931.2131.6731.4731.0031.25 31.06 31.1731.633 2 . 4 231.6731.79 31.6431.8030.8026.910.6% 2.4%2.5%0.6%2.9%0.5%0.5%0.5%0.2%1.0%2.1%2.4%2.1%2.9%SOUTH SHIELDS STREETWESTWARD DRIVE 6' SIDEWALK8' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALK29.19(27.62)(31.13)30.350.8%1.4%1.3% 0.6%0.5%PROPOSED DETENTION POND 1 3 1 . 0 4 31.04 31.10 31.1030.51 30.55 30.80 30.85 31.37 31.34 31.43 31.23 31.23 31.51 31.48 30. 9 031.6730.9431.05TRACT B AE,DE,UERAIN GARDEN BIOMEDIA AREA PROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED STORM INLET PROPOSED CURB INLETPROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 DRAINAGE EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 30' SANITARY SEWER EASEMENT 26' EMERGENCY ACCESS EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE RAIN GARDEN BIOMEDIA AREA PROPOSED POND OUTLET STRUCTURE 26' EMERGENCY ACCESS EASEMENT CONNECT TO EXISTING STORM DRAIN EXISTING 21" RCP STORM DRAIN EXISTING 18" RCP STORM DRAIN PROPOSED TRASH ENCLOSURE FFE=32.92 (3 3 . 3 9 ) (3 3 . 9 0 )(30.65)(30.53)27.71 27.90 28.09 (28.12)(28.60)(29.00)(29.50)(30.43)30.74 3 0 . 7 3 3 0 . 6 831.3031.4231.9331.1331.603 0 . 9 7 31.4631.2531.3931.2431.2931.4531. 2 431.4131.6431.8531.9931. 6 5 30.89 30. 9 8 31.37 32.14(33.35)29.90 31.1726.8332.1932.1630.66 30.6331.16 29.9029.9031.4529.900.5%29.7632.7332.3732.9231.040.5%OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. ±37' FL-FL 60' ROW PROPOSED ROOF DRAIN (TYP.) BIKE BARN (RE: LANDSCAPE)31.4031.6529.8131.8632.8931.4431.3830.7632.2732.23 32.1732.2532.0532.2531.5231.0629.1631.4531.9532.1227.530.5%31.7531.9831.2531.3227.8630.4730.9430.4530.6431.2732.2732.0432.9231.7632.2731.5132.2631.4032.3331.2732.2631.3431.7931.5631.1431.0831.1231. 0 8 31.05 31. 4 0 31. 3 1 31.1031.7831.9731.9231.7232.9232.2531.8331.0031.6431.4631.1231.9631.7631.6431.3531.4631.4831. 5 331.2731.3232.3226.98 3 2 . 1 7 32.59 31.68 26.69 26.88 0.6% PROPOSED 2' CURB CUT 1.0%3.5%0.5%0.5%0.5%2.0% 2.0%0.5%2.0%2.1%1.6%1.0%30.9831.7231.6231.9032.0032.0732.0331. 4 131.5031.88 31.7931.71 31.76 2.2%0.5% 0.5 % 2.6%0.6%31.50 30. 3 6 30.83 0.8%0.5%31.0331.3630.62 3 0 . 7 00.5%PROPOSED 2' CURB CUT 31.1130.6330.3630.2030.0029.1030.0030.0029.60 28.89 29.3128.0929.0626. 9 5 26.8530.0031.09 27.2730.00 30.0030.0030.0529.9129.22 30.4327.72 27. 8 8 31.3430.9130.590.8%30.9130.7531.1331.133 1 . 4 431.3631.89 32.25 31.6631.250.5%1.5%1.5% 32.01 31.5432.01 29.9031.3134.19 34.12 34.0433.75 27.06 27.00 26.92 27.13 31.8132.0132.1032.0032.0231.9731.8531.232.7%2.0%2.6%2.8%2.1% 2.1% 1.9%2.1%2.3%2.3%2.0% 2.2%2.5 % 2.5%2.8%0.9%1.6%1.5%2.2%2.1%1.6%3.4 % 2.4%2.0%2.1%1.6%4:16:15:14:1 4:1 4:16:16:14:14:18:19.4 % 8:1 7:1 6:1 4:1 6:1 21:1 19:1 23:14:16:1 6:1 5:1 9:1 11:1 9:17.4%5:17.9%7:1 3 1 . 7 431.4531.6531.8831.58 31.291.0%1.0%6' SIDEWALK 0.8% 0 . 6%0.5%2.4%2.1%1.1%31.46PROPOSED STORM INLET PROPOSED CURB INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET 31.25PROPOSED AREA INLET PROPOSED 2' CONCRETE PAN 32.92 1.0%0.7%31.5732.252.0%2.3%32.8232.3432.331.5%1.5% 2.3% 29.73 TOW 27.24 FG 26.7326.89 30.990.5%31.0230.710.8%0.8%0.8%0.7%0.7%1.5%1.8%2.0%2.0%3.4%3.4%2.0%2.0%6.2% 7.5%5.3% (32 . 2 7 )31.341.5%31.100.6% 1.1% POND 3 EMERGENCY OVERFLOW PATH POND 2 EMERGENCY OVERFLOW PATH POND 1 EMERGENCY OVERFLOW PATH 30.84 31.3430.2230.7229.6030.1029.7830.6929.2829.1427.0730.00 28.5529.6029.2230.7231.8329.3428.9931.5030.38 30.33 30.70 28.8228.8728.82 31. 7 9 31. 6 8 31.36 0.5%0.5%CONNECT TO EXISTING STORM DRAIN 30.320.5% LANDSCAPE RETAINING WALL RE: LANDSCAPE PLANS LANDSCAPE RETAINING WALL RE: LANDSCAPE PLANS 100-YR WSEL 5029.30 100-YR WSEL 5029.30 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETNORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 502GRADING PLAN 11MATCH LINE - SEE SHEET C 501 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA C 502 C 501 X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D D D D STSTSTSTSTSTSTSTSTSTSTSTSTS T STF.O. F.O. D D / / / / / / / /0.52 ac. OS-2 E E EEEEEEEEEEEEEEEEEEEEEET E E EEEFDCNYLOP L A S T DO NOT PO L L U T E DRAINS TOWATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UDUDUDUD UDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS W W W W W W W W W W W GAS ELEC E T DS DSW WWWWWWWWELECG GGGNYLOP LA S T DO NOT PO L L UT E DRAINS TO WATERWA Y S DO NOT POLL U T E D R A I NS T O WA T E RW A Y S NYLOPLAST D UC T I L E IR O N NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS/ / / / / / / /2.24 ac. 200 1.17 ac. 300 0.40 ac. OS-3 0.93 ac. OS-4 0.13 ac. OS-1 200 300 STORMTECH CHAMBERS PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN OS-2 OS-1 OS-3 OS-4 PROPOSED UNDERDRAIN PROPOSED SIDEWALK CULVERT PROPOSED UNDERDRAIN SOUTH SHIELDS STREETSPRIN G F I E L D D R I V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE EXISTING STORM DRAIN EXISTING STORM DRAIN 9' UTILITY EASEMENT 9' UTILITY EASEMENT DETENTION POND 3 EXISTING 24" STORM DRAIN LOT 3 LOT 4 LOT 1 LOT 2 LOT 5 LOT 7 LOT 6 LOT 9 LOT 8 BLOCK 1 BLOCK 1 TRACT B AE,DE,UE 30' FL-FL57' ROW OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST.100-YR WSEL 100-YR WSEL 0.84 ac. 100 PROPOSED 2' CONCRETE PAN 0.04 ac. OF-2 0.23 ac. OF-1 DETENTION POND 1 UNDERGROUND DETENTION POND 2 RAIN GARDEN A OF 100 0.96 ac. 301 301 0.52 ac. 302 302 POND 3 EMERGENCY SPILL LOCATION POND 1 EMERGENCY SPILL LOCATION CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONof 17REVIEW SETPROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE PRELIMINARY DRAINAGE REPORT FOR FISCHER PROPERTIES BY NORTHERN ENGINEERING, DATED OCTOBER 19, 2022 FOR ADDITIONAL INFORMATION. A LEGEND: C 701DRAINAGE EXHIBIT 17 FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION Rational Flow Summary | Developed Basin Flow Rates BASIN TOTAL AREA (acres) Tc2 (min) Tc100 (min) C2 C100 Q2 (cfs) Q100 (cfs) 100 0.60 5.3 5.3 0.64 0.80 1.10 4.80 200 1.83 5.0 5.0 0.83 1.00 4.33 18.20 300 1.17 6.7 6.7 0.54 0.68 1.63 7.12 301 0.96 5.0 5.0 0.68 0.85 1.86 8.13 302 0.52 5.0 5.0 0.59 0.74 0.87 3.79 OF-1 0.23 7.2 7.2 0.33 0.41 0.19 0.82 OF-2 0.04 5.0 5.0 0.70 0.88 0.08 0.36 OS-1 0.13 5.0 5.0 0.81 1.00 0.31 1.32 OS-2 0.52 10.8 10.8 0.44 0.55 0.49 2.16 OS-3 0.40 8.1 8.1 0.43 0.54 0.41 1.79 OS-4 0.93 10.1 10.1 0.33 0.41 0.68 2.95 POND SUMMARY TABLE Pond ID Extended Detention WQCV (CF)LID WQCV (CF) 100-Yr. Detention Vol. (CF) Total Volume (CF) 100-Yr. Detention WSEL(Ft) Peak Release (cfs) Pond 1 546.00 N/A 3,497.00 4,043.00 5,029.30 0.40 Pond 2 N/A 2,209.00 11,763.00 13,972.00 5,029.40 1.99 Pond 3 997.00 1,474.00 18,311.00 19,308.00 5,031.31 1.10 LID Site Summary - New Impervious Area Total Area of Current Development Total On-site Impervious Area 142,904 ft2 75% Required Minimum Area to be Treated by LID 107,178 ft2 Total On-site Impervious Area Treated by LID 103,467 ft2 Percent On-site Impervious Treated by LID 72.40% Additional Off-site Impervious Area Treated by LID 10,721 ft2 Percent Total Impervious Area Treated by LID 79.91% Total Impervious Area Treated by Traditional WQ 37,005 ft2 Percent Impervious Treated by Traditional Water Quality 25.89% Percent Impervious Area Treated by Traditional WQ or LID 105.80%