HomeMy WebLinkAboutWORTHINGTON STORAGE - FDP220016 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLAN (2)SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI
HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 8 SERIES
HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0"
POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION
SPRAY NOZZLES
30
HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 10 SERIES
HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0"
POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION
SPRAY NOZZLES
30
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
RAIN BIRD XCZ-100-PRB-COM
WIDE FLOW DRIP CONTROL KIT FOR COMMERCIAL APPLICATIONS. 1"
BALL VALVE WITH 1" PESB VALVE AND 1" PRESSURE REGULATING 40PSI
QUICK-CHECK BASKET FILTER. 0.3 GPM-20 GPM
DRIP FLUSH VALVE
3/4" PVC BALL VALVE
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER ICV-G-FS: 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION, WITH NPT THREADED
INLET/OUTLET, FOR COMMERCIAL/MUNICIPAL USE. WITH FILTER
SENTRY.
QUICK COUPLER ASSEMBLY
RAIN BIRD 5-RC: 1" BRASS QUICK-COUPLING VALVE, WITH
CORROSION-RESISTANT STAINLESS STEEL SPRING, THERMOPLASTIC
RUBBER COVER, AND 1-PIECE BODY.
ISOLATION GATE VALVE ASSEMBLY
MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH
SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE.
MASTER VALVE ASSEMBLY
BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER VALVE
THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO MATCH POC
REDUCED PRESSURE BACKFLOW PREVENTER-WILKINS
WILKINS 375B: BACKFLOW PREVENTER WITH BLOW OUT/FLUSH
FITTING. REINFORCED NYLON HOUSING AND CAST BRONZE BALL
VALVES. SIZED TO MATCH TAP & METER (RE: POC NOTE).
PEDESTAL MOUNT TRADITIONAL
HUNTER A2C-2400-SS: 24-STATION CONTROLLER WITH TWO (2) A2M-600
MODULES IN AN OUTDOOR STAINLESS STEEL WALL MOUNT
ENCLOSURE. INSTALL WIRELESS RAIN SENSOR AND SOLAR SYNC
CREATIVE SENSOR TECHNOLOGY FSI-T
1" (SIZE TO MATCH POC) PVC TEE TYPE FLOW SENSOR W/SOCKET
ENDS, CUSTOM MOUNTING TEE AND ULTRA-LIGHTWEIGHT IMPELLER
ENHANCES LOW FLOW MEASUREMENT. 2 WIRE DIGITAL OUTPUT. FLOW
RANGE: .86-52 GPM.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE
SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL
OTHERS BEING 1" IN SIZE.
IRRIGATION LATERAL LINE: PLANTING BED DRIP IRRIGATION LATERAL
LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO
SINGLE OUTLET EMITTERS PER ADJACENT EMITTER CHART.
IRRIGATION LATERAL LINE: NATIVE PLANTING DRIP IRRIGATION LATERAL
LINE:
3/4-INCH BLANK UV RADIATION RESISTANT POLYETHYLENE PIPE TO
TREE RINGS, NETAFIM INLINE DRIP TUBING
MODEL TLCV6-18, AND SINGLE OUTLET EMITTERS FOR SHRUBS PER
ADJACENT EMITTER CHART
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
X-INCH UNLESS OTHERWISE NOTED
IRRIGATION MAINLINE: TYPE K COPPER PIPE
SERVIE LINE PER UTILITY DRAWINGS. SHOWN FOR REFERENCE ONLY
PIPE SLEEVE: PVC SCHEDULE 40
INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE PIPE OR
WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE BUNDLES SHALL
SHARE THE SAME SLEEVE.
A
IRRIGATION_SCHEDULE INSTALLATION GENERAL NOTES
1.DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE AVAILABLE FOR THE IRRIGATION
SYSTEM (PER CITY OR ENGINEER / NOT OBTAINED) OF XX PSI, AT A MAXIMUM PEAK FLOW
OF 10 GPM AT THE 3/4-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW
ON SITE PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S
REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED ABOVE.
2.ALL MAINLINES SHALL BE INSTALLED AT LEAST 5' FROM CENTER OF TREES, WHERE
POSSIBLE. DESIGN IS SHOWN FOR CLARITY, THUS MAINLINE ROUTING IN FIELD MAY LOOK
SLIGHTLY DIFFERENT THAN DEPICTED IN DRAWINGS.
3.CONTRACTOR SHALL CREATE A LAMINATED CONTROLLER CHART ADHERED TO THE
INSIDE OF THE CONTROLLER COVER OR A LAMINATED COLORED CONTROLLER MAP.
4.CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND
INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO CONSTRUCTION. FOR
CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR TO CONSTRUCTION.
4.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED
ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER ENCLOSURE AND
BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS, QUICK COUPLER KEYS, GATE
VALVE KEY, SPRINKLER HEAD AND NOZZLE ADJUSTMENT KEYS.
4.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE PARTS
PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION INSERT, TWO OF
EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE INCLUDED), ONE RCV DIAPHRAGM,
ETC.
5.COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION ("811-CALL BEFORE YOU DIG") .
6.IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS AND
PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S REPRESENTATIVE OR
GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED WITH THE INSTALLATION OF
THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES IN THE FIELD AFFECT THE PROVIDED
DESIGN, DETAILS, OR SPECIFICATIONS.
7.ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.) SHALL BE
INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN THOUGH SAID IRRIGATION
COMPONENTS MAY BE SHOWN OUTSIDE PLANTING AREAS FOR CLARITY.
8. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING MATERIALS, AND
ARCHITECTURAL FEATURES WHENEVER POSSIBLE. COORDINATE POTENTIAL RELOCATION
OF BOULDERS AND TREES IN TURF AREAS WITH LANDSCAPE ARCHITECT PRIOR TO
SPRINKLER LAYOUT. IF LANDSCAPE MATERIAL CANNOT BE RELOCATED,ADDITIONAL
SPRINKLERS MAY BE REQUIRED.
8.1.WHERE POSSIBLE, MAINTAIN 3'-5' DISTANCE FROM CENTER OF TREE TO MAINLINE
AND WIRES. VALVE BOXES SHALL BE AT LEAST 3' FROM TREE CENTER. MAINLINE
ROUTING AND VALVE LOCATIONS ARE SHOWN FOR CLARITY AND MAY BE SHOWN
WITHIN THE 3'-5' RANGE NOTED ABOVE.
9. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND ELBOWS.
10.CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED AREA
CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE CHANGES ARE
REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL CONTACT IRRIGATION
DESIGNER FOR APPROVAL.
11.CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR TO
CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING SLEEVES SHALL
BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS ARE REQUIRED FOR BOTH
PIPING AND ELECTRICAL WIRING AT EACH HARDSCAPE CROSSING. COORDINATE
INSTALLATION OF SLEEVING WITH OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES
BENEATH EXISTING HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE
HORIZONTAL BORING BY THE IRRIGATION CONTRACTOR.
12.INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL
ELECTRIC UTILITY CODES.
13.THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A SECTION OF
UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED SECTIONS, THE UNSIZED
PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED SECTIONS. THE UNSIZED PIPE
SHOULD NOT BE CONFUSED WITH THE DEFAULT PIPE SIZE NOTED IN THE LEGEND.
13.1.MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH MAINLINE LEG
IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG. STATED SIZE IN LEGEND
MAY NOT BE THE LARGEST SIZE ON PLANS.
14.INSTALL THREE (3) #14 AWG CONTROL WIRES FROM CONTROLLER LOCATION TO
EACH DEAD-END OF MAINLINE FOR USE AS SPARES INCASE OF CONTROL WIRE FAILURE.
COIL 3 FEET OF WIRE IN VALVE BOX.
15.TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL ROUTED NEAR
TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN NATIVE SEEDED AREAS
ARE IRRIGATED ON DRIP SYSTEM.
16.VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.
17.NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE SYSTEM BUT
UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT INTENDED TO OPERATE BEYOND
ESTABLISHMENT.
18.NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE, VALVES,
AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING FOUNDATION.
SYMBOL DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE DEDICATED IRRIGATION WATER TAP AND
METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL
PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION
UNIT, MASTER VALVE, AND FLOW SENSOR ASSEMBLY AS
INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S
REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO
CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER
NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW
SHALL BE TESTED UPON INSTALLATION AND ANNUALLY
THEREAFTER.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY
WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL
LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE.
CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE.
1
2
REFERENCE NOTES SCHEDULE
EMITTER SCHEDULE
PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW
GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH
PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH
1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH
5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH
TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH
TREE IN NATIVE SEED INLINE DRIP 0.6 GPH N/A N/A
NOTES:
1.MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB
BEDS.
2.NETAFIM TECHLINE CV DRIP TUBING MODEL TLCV6-18 FOR NATIVE TREE RINGS.
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR1.0 Printed On: 3/8/2023 11:44 AM File Name: IR-WORTHINGTON STORAGE.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
STRATEGIC STORAGE PARTNERS
Alan Westfall
1720 Bellair St.
Denver, CO 80222
p. 303.725.1466
ENGINEER
LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Robbie Lauer, PE
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4185
APPLICANT
1 PDP 03/07/2023
IRRIGATION NOTES
FINAL DEVELOPMENT
PLAN
WORTHINGTON
STORAGE
FORT COLLINS, CO
MLP
MLP
R21-049
IR1.0
NORTH
0 10 20 40
SCALE: 1"=20'-0"
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com
XXXXXXXXXXXXXXX
XXXXST STSTSTSTSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS
S
S
S
S
S
S
S
S
S
S
S
S
S
SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS S
S
S
C
VAULT
ELEC
S
S
ELEC
C
D
FE
SW
HY DW
H2OHYD D
D
CONTROL
IRR WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
W
W
W
W
WWGEEEEEEEEEE
E
E
E
E
E
E
EEE
EEEEEGGGGGGGGGGGGGGGGGGGGXXXXXXXXXXXXCTV C
T
V
C
T
V
C
T
V
C
T
V
C
T
V
C
T
V
C
T
V TTTT TTTEE
E
E
E
EEEEEVAULT
F.O.
S
S FFFFFFFFFFFFFUDUD
UD
UD
UD
UD
UD UDUD
UD UDUD
UD
U
D
U
D
U
D
U
D
U
D
U
D
U
D
UD UDUD
U
D
U
D
UD
UD
UD
UD UDUD
UDUDUDEPOC NO.1
TAP & METER SIZE: 3/4-INCH
PEAK DEMAND: 10 GPM
AVAILABLE PRESSURE: X PSI
-OR-
REQUIRED PRESSURE: X PSI
CONTROLLER 'A'
120 VAC POWER REQUIRED
1
2
(2)3"
NATIVE SEED AREAS ARE TO BE
IRRIGATED WITH A BELOW GRADE
SYSTEM (TYP).
SHRUB BEDS AND TREES AND
SHRUBS IN NATIVE SEED WILL BE
DRIP IRRIGATED WITH POINT
SOURCE DRIP EMITTERS (TYP).
SOD AREAS WILL BE
IRRIGATED WITH EITHER
SPRAY SPRINKLERS OR
ROTOR SPRINKLERS ON 6"
RISERS USING MATCHED
PRECIPITATION RATE
NOZZLES (TYP).
M
A
(2)3"
(2)3"
SYMBOL DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE DEDICATED IRRIGATION WATER TAP AND
METER AT THE APPROXIMATE LOCATION SHOWN (REFER TO CIVIL
PLANS FOR EXACT LOCATION). INSTALL BACKFLOW PREVENTION
UNIT, MASTER VALVE, AND FLOW SENSOR ASSEMBLY AS
INDICATED. VERIFY EXACT LOCATION OF POC WITH OWNER`S
REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR TO
CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER
NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW
SHALL BE TESTED UPON INSTALLATION AND ANNUALLY
THEREAFTER.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR
MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND ENTRY
WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL. FINAL
LOCATION TO BE APPROVED BY OWNER`S REPRESENTATIVE.
CONTROLLER TO BE INSTALLED PER NATIONAL ELECTRIC CODE.
1
2
REFERENCE NOTES SCHEDULE
DRAWING NUMBER:
ISSUED
PROJECT No.:
DRAWN BY:
REVIEWED BY:
SEAL:
PREPARED BY:
No.DESCRIPTION DATE
REVISIONS
No.DESCRIPTION DATE
Plotted By: Michelle peterson Layout: IR1.1 Printed On: 3/8/2023 11:44 AM File Name: IR-WORTHINGTON STORAGE.dwgORIGINAL SIZE 24X36
ENTI
T
L
E
M
E
N
T
DRA
WI
N
G
S
NOT
F
O
R
CON
S
T
R
U
C
TI
O
N
419 Canyon Ave. Suite 200 Fort Collins, CO 80521
phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com
RIPLEY DESIGN INC.
Sam Coutts, PLA
419 Canyon Ave. Suite 200
Fort Collins, CO 80521
p. 970.224.5828
f. 970.225.6657
STRATEGIC STORAGE PARTNERS
Alan Westfall
1720 Bellair St.
Denver, CO 80222
p. 303.725.1466
ENGINEER
LANDSCAPE ARCHITECT
NORTHERN ENGINEERING
Robbie Lauer, PE
301 N. Howes St. Suite 100
Fort Collins, CO 80521
p. 970.221.4185
APPLICANT
1 PDP 03/07/2023
IRRIGATION PLAN
FINAL DEVELOPMENT
PLAN
WORTHINGTON
STORAGE
FORT COLLINS, CO
MLP
MLP
R21-049
IR1.1
NORTH
0 10 20 40
SCALE: 1"=20'-0"
MPi Designs
PO BOX 369 ● AULT, CO ● 80610
970-402-3047
Michelle@MPiDesignsllc.com