Loading...
HomeMy WebLinkAboutPOWERHOUSE 2 - FDP220015 - SUBMITTAL DOCUMENTS - ROUND 2 - SUPPORTING DOCUMENTATION 351 LINDEN STREET, SUITE 100 FORT COLLINS, CO 80522 970 -232-9558 www.pec1.com December 06, 2022 To whom it may concern City of Fort Collins Utilities Development Review Division Reference: Powerhouse 2 Climate Solutions Campus 202 East Vine Drive Fort Collins, CO 80524 Estimated Usage The intent of this letter is to document and justify the estimated peak day and annual usage at the Powerhouse 2 Climate Solutions Campus located at 202 East Vine Drive for the purpose of sizing a new water meter for the building and its addition. The existing Powerhouse 1 at 430 N College Ave #425, Fort Collins Colorado, is approximately 100,000 sf and the new building will be approximately 165,000 sf. The existing building and the new building will have similar occupancy types as they are both comprised of office spaces, conference rooms, a small number of large assembly spaces and miscellaneous lab/research spaces used by students/staff. Building is not intended to operate 24/7 similar to existing Powerhouse 1. The charts on the next page use calculations based on the existing building to extrapolate an average water usage per SF for a research and office building similar to that of Powerhouse 2. 351 LINDEN STREET, SUITE 100 FORT COLLINS, CO 80522 970 -232-9558 www.pec1.com Existing Building Usage The existing building uses its water tap for both irrigation and cooling through an evaporative cooling tower. The new Powerhouse 2 building will have a separate irrigation tap and will use other cooling methods that do not continuously consume water to produce cooling. A yearly water consumption from 2021 for the existing Powerhouse 1 building was provided to PEC by the owner. A snip of the yearly usage is shown below. The monthly average for months when the evaporative cooling and irrigation can be excluded are highlighted in yellow. Results Given the above data and the estimated flow, it is safe to assume the new building will follow a similar water usage per SF as the months that do not use irrigation or evaporative cooling. The average Gallons/SF/Month for the months highlighted in yellow is 3.021 Gallons/Sf/Year. Based on the new building area of 165,000 Sf the yearly water consumption can be estimated as roughly 579,500 Gallons. Regards, Chad Schilt Professional Engineering Consultants CONSUMPTION WATER SEWER STORM DMC TOTAL (GALLONS)($)($)($)($)($) Jul-20 360,900.0 1,184.4 249.1 443.0 - 1,876.5 0.003 3.609 Aug-20 401,300.0 1,296.5 249.1 443.0 - 1,988.6 0.003 4.013 Sep-20 401,500.0 1,297.1 249.1 443.0 - 1,989.2 0.003 4.015 Oct-20 33,700.0 222.2 249.1 443.0 - 914.3 0.007 0.337 Nov-20 16,100.0 218.3 249.1 443.0 - 910.4 0.014 0.161 Dec-20 23,200.0 234.0 249.1 443.0 - 926.1 0.010 0.232 Jan-21 22,100.0 236.2 249.1 443.0 - 928.3 0.011 0.221 Feb-21 8,400.0 205.2 249.1 443.0 - 897.3 0.024 0.084 Mar-21 15,700.0 221.7 146.3 443.0 - 811.0 0.014 0.157 Apr-21 32,600.0 260.0 146.3 443.0 - 849.3 0.008 0.326 May-21 49,600.0 326.6 146.3 443.0 - 915.9 0.007 0.496 Jun-21 412,200.0 1,353.5 146.3 443.0 - 1,942.8 0.003 4.122 Total 1,777,300.0 7,055.6 2,577.8 5,316.1 - 14,949.5 12 Month Average 148,108.3 588.0 214.8 443.0 - 1,245.8 Yellow Month Average 25,175.0 240.5 210.5 443.0 - 894.1 $/gal consume Gallon/SF/Month Powerhouse 1 - Water Consumption FY21 If assumed that these months do not use evap. cooler or irrigation which is why they have the lower water consumption.