Loading...
HomeMy WebLinkAboutIMPALA REDEVELOPMENT - FDP230001 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANSWEST MULBERRY STREET SOUTH TAFT HILL ROADLAPORTE AVENUE C 100COVER SHEET 1 Original Field Survery: Northern Engineering Project No. 370-005 Date: December 28, 2021 Additional Field Survey: Northern Engineering Project No. 370-005 Date: March 17, 2022 JANUARY 2023 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH Project Datum: NAVD88 Benchmark 25-97 At the Southwest corner of Mulberry St. and Taft Hill Rd., on a concrete traffic signal base. Elevation = 5071.25 Benchmark 24-97 On a concrete headwall pipe in Rogers Park. South of the parking area of Rogers Park (150 feet South of large barn) 2500 block of Mulberry St. Elevation = 5102.71 Please Note: this plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (prior City of Fort Collins datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins datum) = NAVD88 - 3.17' Basis of Bearings The South line of the Southeast Quarter of Section 9, Township 7 North, Range 69 West of the 6th P.M. bearing North 88°51'30", as shown on ALTA. PROJECT BENCHMARKS: IMPALA REDEVELOPMENT PROJECT TEAM: Housing Catalyst Nichole Rex, Senior Project Manager 1715 W. Mountain Avenue Fort Collins, CO 80521 (970) 416-2910 Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER GEOTECHNICAL ENGINEER CTL | Thompson, Inc. Trace Krausse, EI 400 N Link Ln Fort Collins, CO 80524 (970) 206-9455 SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 9, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO (306 & 400 IMPALA CIRCLE) FIELD SURVEY BY: Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE SURVEYOR 1 C 100 COVER SHEET 2 C 101 GENERAL & CONSTRUCTION NOTES 3-5 C 102 - C 104 EXISTING CONDITIONS & DEMOLITION PLAN 6-8 C 200 - C 202 CIVIL SITE PLAN UTILITY SHEETS 9 C 300 OVERALL UTILITY PLAN 10-12 C 301 - C 303 UTILITY PLAN STORM DRAIN PROFILE SHEETS 13 C 310 STORM DRAIN 1 PLAN & PROFILE 14 C 311 STORM DRAIN 2 PLAN & PROFILE 15 C 312 STORM DRAINS 2-2 & 2-4 PLAN & PROFILE GRADING SHEETS 16 C 400 OVERALL GRADING PLAN 17-19 C 401 - C 403 GRADING PLAN DETAIL SHEETS 20 C 500 WATER DETAILS 21 C 501 SANITARY DETAILS 22-24 C 502-C 504 DRAINAGE DETAILS 25-26 C 505-C 506 SITE DETAILS DRAINAGE SHEETS 27 C 600 EROSION CONTROL PLAN 28 C 601 EROSION CONTROL DETAILS 29 C 610 HISTORIC DRAINAGE EXHIBIT 30 C 611 DEVELOPED DRAINAGE EXHIBIT UTILITY PLANS CTL | Thompson Preliminary Geotechnical Investigation 306 and 400 Impala Circle Fort Collins, Colorado CTL|Thompson Project No. FC10389-115 Date: June 3, 2022 SUBSURFACE EXPLORATION BY: E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 30 PROJECT LOCATION Ripley Design, Inc. Russ Lee, President 419 Canyon Avenue, Suite 200 Fort Collins, CO. 80521 (970) 224-5828 APPROVED: CITY ENGINEER:APPROVED SHEETS DATE WATER & WASTEWATER UTILITY:APPROVED SHEETS DATE STORMWATER UTILITY:APPROVED SHEETS DATE PARK PLANNING AND DEVELOPMENT:APPROVED SHEETS DATE TRAFFIC OPERATIONS:APPROVED SHEETS DATE ENVIRONMENTAL PLANNER:APPROVED SHEETS DATE City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 1/31/2023 This does not match the title on this sheet. 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W EEEEEEEEEEE E EEEEEEEEEG G GGGG G GG G G GGGGGGGGGGEEEEEEE CTVCTVCTVCTVCTVEEE6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" WCTV CTV CTV CTV CTVCTV CTV CTV CTVCTVEE E E EE E E E EE E E E E E E E E E VAULT ELEC VAULT ELEC CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC C VAULT ELEC X X X X X X X G GXXXXXXXXXXXE E8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS W S S FO 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W 16" W X X X X X X XGGGGGGGGGFOFO FOFOFOFOFOFOFOFOFOFOTTTTTTTTTTTTT T G G XXXXXXXXXXXXXXXWF UD UD UD UDSW FWT TT G EE E G G G F SSIRRIR E E GGGGGIMPALA CIRCLE SOUTH IMPALA DRIVE26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 26' FL-FL 7' SIDEWALK 6' SIDEWALK 7' SIDEWALK8' S IDEWALK 5' SIDEWALK6' SIDEWALK6' SIDEWALK8.5' SIDEWALK5' SIDEWALKEASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSION PROPOSED UNDERDRAIN PROPOSED 1.5" WATER METER PIT PROPOSED FIRE SERVICE (TYP.) EXISTING 8" SANITARY SEWER EXISTING 16" WATER EXISTING 8" SANITARY SEWER EXISTING 6" WATER PROPOSED 2' CONCRETE PAN EXISTING ELECTRIC LINES (TYP.) EXISTING 6' CONCRETE PAN EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING 8" SANITARY SEWER EXISTING SANITARY SEWER MANHOLE (TYP.) EXISTING 6" WATER EXISTING FIRE HYDRANT EXISTING FIBER OPTIC LINE EXISTING 16" WATER ±31' FL-FL (TYP.) ±24' FL-FL (TYP.)IMPALA CIRCLE PROPOSED AREA DRAIN (TYP.) PROPOSED AREA DRAIN (TYP.)5' SIDEWALKEXISTING CABLE TV LINE (TYP.) PROPOSED 1" WATER METER PIT EXISTING 6" WATER PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PUBLIC ACCESS EASEMENT (WIDTH VARIES) 3' CONCRETE TRAIL 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED LANDSCAPE WALL W/ HANDRAIL RAIN GARDEN BIOMEDIA AREA OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. PROPOSED FIRE SERVICE (TYP.) 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 18' WIDE OVERFLOW WEIR PROPOSED TRANSFORMER (TYP.) EASEMENT EXCLUSION PROPOSED IRRIGATION TAP 8.5' SIDEWALKSAN SERVICE B INV. OUT=5086.94 (W) FG=5094.82 42.09 LF 6" PVC @ 2.00% SVC. CONNECTION B INV. IN=5085.99 (N) INV. IN=5086.10 (E) INV. OUT=5085.99 (S) FG=5094.12 SAN SERVICE A INV. OUT=5080.26 (E) FG=5091.94 89.65 LF 4" PVC @ 2.00% EXSSMH A INV. IN=5078.47 (W) FG=5088.36 SVC. CONNECTION C INV. IN=5077.21 (N) INV. IN=5077.04 (W) INV. OUT=5077.04 (E) FG=5088.12 86.52 LF 6" PVC @ 2.00% SAN CLEANOUT C-1 INV. IN=5078.94 (W) INV. OUT=5078.94 (S) FG=5088.99 57.72 LF 6" PVC @ 2.00% SAN SERVICE C INV. OUT=5080.09 (E) FG=5091.64 82.34 LF 4" PERFORATED PVC @ 0.50% 13.13 LF 12" HDPE @ 0.50% FES 1-1 INV. IN=5084.82 (W) FG=5084.82 CLEANOUT 1-3 INV. OUT=5085.30 (E) FG=5086.40 INLET 1-2 INV. IN=5084.88 (W) INV. OUT=5084.88 (E) FG=5087.40 PROPOSED WATER SERVICE PROPOSED WATER SERVICE PROPOSED WATER SERVICE PROPOSED 1.5" WATER METER PIT STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2 SEE SHEET C 311 STORM DRAIN 2-2 SEE SHEET C 312 STORM DRAIN 2-4 SEE SHEET C 312 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 30 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE SHEET C 302 C 301UTILITY PLAN 10 C 301 C 302 C 303 Line Over Text & Text Over Text 1/31/2023 **All circled are line over text, except as noted.** 6" W 6" W 6" W6" W6" W6" W6" W6" WG G GGGG G GG G G G G G G GEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVEEE6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W G GGGGGGGGGGG GGGGGGGGGGGGGCTV CTV CTV CTV CTVCTV CTV CTV CTVCTV C T V CTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV CTV CTV CTVCTVCTVCTV CTVCTVCTVCTV CTVCTV CTV C T V CTVCTVCTV CTV CTVCTVCTVCTVCTVCTV CTV CTV CTV CTVCTV CTV CTVCTVCTVEE E E EE E E E E E E E EEEEEEEEEEEEEEE E E E E EEE E E EEEEEEEE EEEE E E E E E E E E E E EEEEEEEEEEEE E E E E E E EEE E E CABLE VAULT ELEC S S VAULT ELEC VAULT CABLE VAULT CABLE HYDC CT C C CABLE C TC T C C C T C VAULT ELEC X X X X X X X X X X X X X X X X XXXXXXXXXXXXXXXXXXXXXW W W WW WXXXXX XXXXXXS W W G G G G G G G G G GXE E E E E E E E E E E GGGG G GG8" SS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSXXXXXXXX X X X X X X X X X X X X X X X X6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECUD UD UD UD FT EEEEE GGG26' FL-FL PROPOSED 2' CONCRETE PAN 5' SIDEWALKPROPOSED UNDERDRAIN PROPOSED POND OUTLET STRUCTURE PROPOSED 1.5" WATER METER PIT EXISTING 8" SANITARY SEWER EXISTING CONCRETE PAN EXISTING 8" SANITARY SEWER PROPOSED 2' CONCRETE PAN EXISTING 6" WATER EXISTING 8" SANITARY SEWER EXISTING ELECTRIC LINES (TYP.)EXISTING GAS LINE (TYP.) EXISTING BUILDINGS (TYP.) EXISTING 6' CONCRETE PAN EXISTING FIRE HYDRANT EXISTING 2' CONCRETE PAN EXISTING CABLE TV LINE (TYP.) ±24' FL-FL (TYP.)IMPALA CIRCLE5' SIDEWALKEXISTING CABLE TV LINE (TYP.) EXISTING CABLE TV LINE (TYP.) 3' CONCRETE TRAIL 3' C O N C R E T E T R AI L PROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED LANDSCAPE WALL W/ HANDRAIL DETENTION POND 1 RAIN GARDEN BIOMEDIA AREA EXISTING SIDEWALK CULVERT EXISTING HEADWALL & OVERFLOW WEIR REMOVE EXISTING ORIFICE PLATE REPLACE WITH SOLID PLATE OWNER: TRISSELL, NICOLE/COGELL, CHRISTOPHER 408 S IMPALA DR. OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: POUDRE R-1 SCHOOL DISTRICT OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/PATRICIA A 2212 WOODFORD CT. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. OWNER: VILLAGES, LTD. 400 IMPALA CIR. PROPOSED FIRE SERVICE (TYP.) 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT PROPOSED 18' WIDE OVERFLOW WEIR PROPOSED TRANSFORMER (TYP.) ADJUST MANHOLE CONE ELEVATION TO MATCH FLUSH ISLAND EASEMENT EXCLUSION EASEMENT EXCLUSION EASEMENT EXCLUSIONEASEMENT EXCLUSION8.5' SIDEWALK30' 89.65 LF 4" PVC @ 2.00% EXSSMH A INV. IN=5078.47 (W) FG=5088.36 SVC. CONNECTION C INV. IN=5077.21 (N) INV. IN=5077.04 (W) INV. OUT=5077.04 (E) FG=5088.12 86.52 LF 6" PVC @ 2.00% 82.34 LF 4" PERFORATED PVC @ 0.50% 13.13 LF 12" HDPE @ 0.50% FES 1-1 INV. IN=5084.82 (W) FG=5084.82 CLEANOUT 1-3 INV. OUT=5085.30 (E) FG=5086.40 INLET 1-2 INV. IN=5084.88 (W) INV. OUT=5084.88 (E) FG=5087.40 STORM DRAIN 1 SEE SHEET C 310 CUT BACK EXISTING PIPE INSTALL RIP-RAP DOWNFALL CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 30 MATCH LINE - SEE SHEET C 303 C 302UTILITY PLAN 11 MATCH LINE - SEE SHEET C 301 C 301 C 302 C 303 1/31/2023 **All circled are line over text.** CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVGGGGGGGG G G G G GGGGGGGCTVCTVCTV CTVCTVCTVCTV CTVCTVCTVCTVCTV CTVCTVCTVCTVCTV CTV CTV CTV CTVCTV CTV CTVCTVCTVEEE E E EEEEEEE EE E E E E EEEEEEEE E E EEE E E GGGGGXXXXXXCABLE C TC C T C HYDVAULT F.O.XXXXXXXXXXXXXXXXXXXXXXG G G G G G E E E E E GGGGG S 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSIRR IRRIRRIRRIRRIRRIRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR C D SS D 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST STSTSTCTVCTVCTVCTVCTVCTVCTVCTVCTVGGGGGGGGGGFOFOFOFOFOFOFOFOFOFOFOFO FOEEEEE E 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" W6" WELECSGGGGGGGWFEEEEEEEEEEEEEEET WEST MULBERRY STREET PROPOSED LANDSCAPE WALL W/ HANDRAIL 6' SIDEWALKEASEMENT EXCLUSION EXISTING 15" STORM DRAIN PROPOSED WATER SERVICE EXISTING 8" SANITARY SEWER EXISTING 6" WATER EXISTING 8" SANITARY SEWER PROPOSED 3' SIDEWALK CULVERT EXISTING 36" STORM DRAIN EXISTING GAS LINE EXISTING 10" SANITARY SEWER EXISTING 8" WATER EXISTING BUILDINGS (TYP.) EXISTING FIBER OPTIC LINE EXISTING 2' CONCRETE PAN EXISTING SANITARY SEWER MANHOLE (TYP.) EXISTING CABLE TV LINE (TYP.) 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT 51.5' EMERGENCY ACCESS EASEMENT PROPOSED GAS LINE RELOCATION EXISTING STORM DRAIN MANHOLE (TYP.) EXISTING 18" CLAY IRRIGATION LINE (APPROX.) OWNED BY CITY OF FORT COLLINS PARKS DEPARTMENT PROPOSED RIP-RAP RUNDOWN DETENTION POND 2 OWNER: VON STROHEIM, ERICH 2310 W MULBERRY ST. OWNER: EMPIRE GRANGE 148 2306 W MULBERRY ST. OWNER: KEELER, JACK LEE/ GAIL, MARGARET 2302 W MULBERRY ST. OWNER: RICKETTS, THERESA A. 2300 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT. OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: VILLAGES, LTD. 400 IMPALA CIR. PROPOSED 2' SIDEWALK CHASE 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 6'CONCRETE TRAIL6'CONCRETE TRAILPROPOSED FIRE SERVICE PROPOSED HEADWALL W/ WATER QUALITY PLATE PROPOSED 1" WATER METER PIT EXISTING HEADWALL & OVERFLOW WEIR ADJUST MANHOLE CONE ELEVATION TO MATCH FLUSH ISLAND EASEMENT EXCLUSIONEASEMENT EXCLUSION 24' EMERGENCY ACCESS EASEMENT FOR REFERENCE: REPLACEMENT OF IRRIGATION LATERAL BY CITY OF FORT COLLINS PARKS DEPT. POSSIBLE DURING CONSTRUCTION CONTRACTOR TO COORDINATE WITH CITY OF FORT COLLINS SVC. CONNECTION D INV. IN=5073.69 (S) INV. IN=5074.02 (E) INV. OUT=5073.69 (N) FG=??? 47.16 LF 4" PVC @ 2.00% SAN SERVICE D INV. OUT=5074.97 (W) FG=5085.15 STORM DRAIN 1 SEE SHEET C 310 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE 4.5'-5.5' COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.CONTRACTOR SHALL COORDINATE TIMING OF UTILITY INSTALLATIONS WITHIN IMPALA DRIVE WITH CITY OF FORT COLLINS TRAFFIC OPERATIONS IN ORDER TO MINIMIZE DISRUPTION OF TRAFFIC IN SCHOOL ZONE. 12.CONTRACTOR SHALL COORDINATE TIMING OF IRRIGATION LINE RELOCATION WITH CITY OF FORT COLLINS PARKS DEPARTMENT IN ORDER TO PREVENT SERVICE DISRUPTION DURING PERIODS OF HIGH DEMAND. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT SS PROPOSED LOT LINE EXISTING ROW EXISTING CABLE CTV W KEYMAP SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 30 MATCH LINE - SEE SHEET C 302 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 303UTILITY PLAN 12 C 301 C 302 C 303 1/31/2023 **All circled are line over text.** GGGG G G G G CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVEEE EE EE EEE E EEEG XXCCTCCCABLECTCHY DVAULTF.O.XXXXXXXXXXXXXXXWWSWGGGGGGEEEEEE8" SSS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SSIRR IRR IRR IRR CDSS10" SS10" SS10" SS10" SS10" SS10" SSSTSTSTSTSTSTSTXXXXXXX XCTVCTVCTVGGGFOFOFOFOEE8" W8" W8" W8" W8" W8" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W ELECSGGGWFEEE ETOUTLET 1-5 STA 15+76.34 N: 129825.57 E: 183216.52 FES 1-1 STA 10+00.00 N: 129268.49 E: 183211.51 CLEANOUT 1-2 STA 10+17.95 N: 129281.04 E: 183224.35 13.98 LF 15" HDPE @ 0.50% 400.00 LF 15" HDPE @ 0.50%17.95 LF 15" HDPE @ 0.30% STMH 1-4 (FLAT TOP) STA 15+62.36 N: 129825.41 E: 183230.50 144.41 LF 15" HDPE @ 0.30% STMH 1-3 (FLAT TOP) STA 11+62.36 N: 129425.43 E: 183225.98WEST MULBERRY STREETPROPOSED LANDSCAPE WALL W/ HANDRAIL PROPOSED 2' CONCRETE PANEASEMENT EXCLUSION EXISTING 15" STORM DRAIN EXISTING CONCRETE PAN EXISTING 36" STORM DRAIN EXISTING STORM DRAIN MANHOLE (TYP.) PROPOSED LANDSCAPE WALL W/ HANDRAIL DETENTION POND 1DETENTION POND 2 OWNER: BAILEY, MICHAEL 2213 WOODFORD CT. OWNER: HAUAN, JAMES P/PATRICIA A 2212 WOODFORD CT. OWNER: SIKORSKI, MITCHELL ANDREW 2213 W MAGNOLIA CT.OWNER: GODING, BRYAN T. 2218 W MULBERRY ST. OWNER: STEADMAN, VIVIAN LOUISE 2212 W MAGNOLIA CT. OWNER: VILLAGES, LTD. 400 IMPALA CIR. PROPOSED HEADWALL W/ WATER QUALITY PLATE EXISTING HEADWALL & OVERFLOW WEIR EASEMENT EXCLUSION EASEMENT EXCLUSION 10' CITY OF FORT COLLINS PARKS DEPT. IRRIGATION LATERAL EASEMENT IMPALA CIRCLE 24' PUBLIC ACCESS & EMERGENCY ACCESS EASEMENT 5060 5065 5070 5075 5080 5085 5090 5095 5100 5060 5065 5070 5075 5080 5085 5090 5095 5100 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+505082.945085.535085.335083.23FES 1-1STA 10+00.00INV. 5080.21 (NE)17.95 LF 15" HDPE @ 0.30% 400.00 LF 15" HDPE @ 0.50% 13.98 LF 15" HDPE @ 0.50%OUTLET 1-5STA 15+76.34FL. EL 5084.9±INV. OUT 5082.77 (E)EXISTING GROUNDPROPOSED GROUND EXISTING GROUND PROPOSED GROUNDSTMH 1-3 (FLAT TOP)STA 11+62.36RIM 5083.5±INV. IN 5080.70 (N)INV. OUT 5080.70 (S)STMH 1-4 (FLAT TOP)STA 15+62.36RIM 5085.2±INV. IN 5082.70 (W)INV. OUT 5082.70 (S)STA.=11+90.76 EXPECTED CROSSING FOR IRRIGATION LATERAL UNABLE TO LOCATE KEYMAP C 310PLAN & PROFILESTORM DRAIN 113 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 PROFILE SCALE: STORM DRAIN 1 SheetIMPALA REDEVELOPMENTThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 30 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER EASEMENT LINE 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3.PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4.ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY CITY OF FORT COLLINS STORMWATER CRITERIA MANUAL (FCSCM), LATEST EDITION. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5.CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). 6.SEE DETAIL SHEET (XX) FOR RIP-RAP SCHEDULE. PROPOSED RIGHT OF WAY INLET SCHEDULE: FOR REFERENCE: REPLACEMENT OF IRRIGATION LATERAL BY CITY OF FORT COLLINS PARKS DEPT. POSSIBLE DURING CONSTRUCTION CONTRACTOR TO COORDINATE WITH CITY OF FORT COLLINS 1/31/2023 **All circled are line over text.** 6" W6" W6" W6" W 6" W 6" W 6" W 6" W6" W6" WE E E E EE E E GGGGGGG G G E E CTVCTVCTVCTVCTVCTVCTVE 6" W6" W6" WGGGGGGG G G G G CTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTVCTVCTVCTV EEEEEE EE EE EEE E EEEEEE E EEEEE EG XXVAULTELECVAULTELECCABLEVAULTELECSSVAULTELECVAULTCABLEVAULTCABLEHYDCCTCCCABLECTCTCCCTCVAULTELECHY D VAULTF.O.XXXXXXXXXXXXXXXXXWWXXXXXXSWWGGGGGGGGGGGGX X X X EEEEEEEEEEEE8" SS8" SS8" SSS8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS IRR IRR IRRIRRIRRIRR IRR IRR WCSSSFODSSDS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS10" SS8" SS8" SS8" SS8" SS8" SS 8" SS 8" SS 8" SSST STSTSTSTSTSTSTSTSTSTSTSTSTSTSTST16" W16" W16" W16" W16" W 16" W 16" W 16" W16" W16" W16" W16" WXXXXXXXXX XCTVCTVCTV G G GFOFOFOFOTTTTT GGGFOFOFOFOEE8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W8" W6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W ELECXXXXXXUDCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOUDIG, GRADE, OR EXCAVATE FOR THE MARKING OFUNDERGROUND MEMBER UTILITIES.CALL UTILITY NOTIFICATION CENTER OFCOLORADOKnow what'sbelow.before you dig.CallRNORTH( IN FEET )1 inch = ft.Feet0505050100150PROPOSED CONTOURPROPOSED STORM SEWERPROPOSED SWALEEXISTING CONTOURPROPOSED CURB & GUTTERPROPERTY BOUNDARYBENCHMARK/BASIS OF BEARING:SILT FENCEROCK SOCKRIPRAP1.CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BYCRIMP MULCHING OR SIMILAR METHODS.2.SWMP ADMINISTRATOR:Contact________________________________Company________________________________Address________________________________Phone________________________________3.CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETEWASHOUT AREA IF ACCESS IS OFF PAVEMENT.4.REFER TO THE FINAL DRAINAGE REPORT, DATED JANUARY 11, 2023 BYNORTHERN ENGINEERING FOR ADDITIONAL INFORMATION.GENERAL NOTES:WATTLE DIKECONCRETE WASH AREALEGEND:SFC 600EROSION CONTROL PLAN27 BENCHMARK #1:CITY OF GREELEY GIS #13, CAP ID #108 BMN: 1397556.01E: 3197324.07ELEVATION = 4816.38 (NAVD88)BASIS OF BEARINGBASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHEAST QUARTER OFSECTION 11, TOWNSHIP 5 NORTH, RANGE 67 WEST AS BEARING NORTH 89° 37'03" WEST (ASSUMED BEARING)HORIZONTAL DATUMCOORDINATE SYSTEM IS A NORTHERN ENGINEERING LOCAL COORDINATESYSTEM BASED ON MODIFIED STATE PLANE COORDINATES SCALED AT1.00026470 (0.99973537) ABOUT (0,0). LINEAL MEASURE IS BASED ON THE U.S.SURVEY FOOT.SheetIMPALA REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc.NOT FOR CO N S T R U C T I O N REVIEW SE T of 30KEYMAPSFSFSFSF SF SF SF SF SF SF SF SF SF SF SF SF SFSFSFSFSFSFSFSFSFSFSFSFSF100' (TYP.)OUTLET PROTECTIONINLET PROTECTIONVEHICLE TRACKING CONTROL PAD1/31/2023**All Benchmark Statements must match on all sheets.**