Loading...
HomeMy WebLinkAbout1323 W Plum St Wireless Telecommunication Equipment - BDR230002 - Plans SUBMITTAL DOCUMENTS - ROUND 1 - 01/25/2023 • SITE INFORMATION PROJECT DIRECTORY PROPERTY OWNER: PLUM OWNER APPLICANT. DISH WIRELESS, LLC. _ 5G LLC SITE ID: Fr DOLLING LLC ENEGEWOC MERIDIAN0 2dl�004 1253 GYS R _ h ADDRESS ME SHADY GROVE RD STE 600 wireless- ROOFTOP TN 38120 SITE DESIGNER: 6WYCO335 FIELD SERVICES 6335 DOWNING ST ROOFTOP MANAGER: 5G LLC. DENVER, CO 80216 (303) 954-02L 9601 5. MERIDIAN BLVD. C1 S 1i SCOPE OF WORK BUILDING TYPE: ROOFOTP ENGLEWOOD, CO 80112 SITE ACQUISITION: KENNETH TRUJILO THIS IS NOT AN ALL INCLUSIVE LIST. CONTRACTOR SHALL UTILIZE SPECIFIED EQUIPMENT PART OR ENGINEER APPROVED EQUIVALENT, CONTRACTOR SHALL VERIFY ALL NEEDED EQUIPMENT TO PROVIDE A FUNCTIONAL SITE, COUNTY: LARIMER COUNTY (719) 205-9370 wi re I eSS THE PROJECT GENERALLY CONSISTS OF THE FOLLOWING SECTOR SCOPE OF WORK: LATITUDE: 40' 34' 34.0032" A&E PROJECT MANAGER: MICHAEL LASITER • INSTALL (3) PROPOSED PANEL ANTENNAS (1 PER SECTOR) 7ry1 (941) 274-6002 • INSTALL (3) PROPOSED ANTENNA MOUNTS (1 PER SECTOR)INSTAL PROPOSED JUMPERS LONGITUDE: -105' 5' 57.9048" • L r^ • INSTALL (6) PROPOSED RRUs (2 PER SECTOR) CONSTRUCTION MANAGER: SCOTT TOMLINSON L • INSTALL (3) PROPOSED OVER VOLTAGE PROTECTION DEVICE (OVP) (1 PER SECTOR) ZONING JURISDICTION: CITY OF FORT COLLINS (720) 788-6655 FIELD SERVICE S DISH Wireless L.L.C. SITE ID: INSTALL (3) PROPOSED POWER CABLES (1 PER SECTOR) • INSTALL (3) PROPOSED FIBER CABLES (1 PER SECTOR) \\here quality still counts. D N D E N 00178 B • INSTALL PROPOSED 4" CONDUIT FOR POWER AND FIBER ZONING DISTRICT: C-C COMMUNITY COMMERCIAL FOR: TIM ALEXANDER • INSTALL PROPOSED UNISTRUT WALL MOUNTS (602) 403-8368 6335 DOWNING ST ROOFTOP SCOPE OF WORK: PARCEL NUMBER: 971515300 DENVER, CO 80216 • INSTALL (1) PROPOSED PRE-MANUFACTURED METAL PLATFORM WITH H-FRAME RE ENGINEER: ROBERT CARISTAN • INSTALL (1) PROPOSED CABLE LADDER TRAY OR CABLE TRAY OCCUPANCY GROUP: BT-1 (720) 227-2221 DISH Wireless L.L.C. SITE ADDRESS: . INSTALL (1) SUB-METER BY AS PANEL 1323 WEST PLUM STREET ' INSTALL (1) PROPOSED BBU IN CABINET • INSTALL (1) PROPOSED EQUIPMENT CABINET CONSTRUCTION TYPE: V-B � INSTALL (1) PROPOSED POWER CONDUIT UNIT DISH • INSTALL (1) PROPOSED TELCO CONDUIT • INSTALL (1) PROPOSED NEMA 3 TELCO-FIBER BOX POWER COMPANY: FORT COLLINS LIGHT POWER • INSTALL (1) PROPOSED CPS UNI 1,T ' INSTALL (2) PROPOSED VOLTAGE BOOSTERS TELEPHONE COMPANY BD FORT COLLINS, CO 80521 CODE COMPLIANCE SITE PHOTO DIRECTIONS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF DIRECTIONS FROM DISH WIRELESS, LLC. OFFICE: THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: GET ON E-470 N FROM BELFORD AVE CODE TYPE CODE / � (1.7 MI). FOLLOW E-470 N AND I-25 N TO CO-14 W/E MULBERRY ST IN LARIMER COUNTY. TAKE EXIT 269E BUILDING 2021 IBC ^� FROM 1-25 N (86.1 MI). MERGE ONTO E-470 N (43.9 MI). TAKE EXIT 47 TO MERGE ONTO 1-25 N TOWARD FT MECHANICAL 2021 IMC COLLINS (22.2 MI). KEEP RIGHT AT THE FORK TO STAY ON I-25 N (19.8 MI). TAKE EXIT 269B TO MERGE ONTO ELECTRICAL 20211 NEC CO-14 W/E MULBERRY ST TOWARD FT COLLINS (0.3 MI). FOLLOW E MULBERRY ST TO W PLUM ST IN FORT FIRE 2021 IFC COLLINS (5.5 MI) MERGE ONTO CO-14 W/E MULBERRY ST CONTINUE TO FOLLOW E MULBERRY ST (5.0 MI). IT IS A VIOLATION OF LAW FOR ANY PERSON, TURN LEFT ONTO S SHIELDS ST PASS BY 7-ELEVEN (ON THE RIGHT) (0.4 MI). TURN RIGHT ONTO W PLUM ST. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, DESTINATION WILL BE ON THE LEFT. TO ALTER THIS DOCUMENT. SHEET INDEX VICINITY MAP DRAWN BY: CHECK A ED BY]APPROVED BY i : SHEET NO. SHEET TITLE REDS REV #: 11/2/21 1r� ol T—, TITLE SHEET CONSTRUCTION EST SITE SURVEY LS1 SITE SURVEY - f - ---r.1 I `•* `- . ;/ DOCUMENTS EST SITE SURVEY r. 1 me•.ya A-1.1 PARCEL MAP SUBMITTALS, p � -�� A-1.2 OVERALL SITE PLAN _ _ - I 0.,t..,fl - REV DATE DESCRIPTION A-1.3 SU DP (SEWER USE AND DRAINAGE PERMIT SITE PLAN) 1 ,C '"""'�'�, - �.,-• "„„a s 's A 11/29/21 ISSUED FOR REVIEW A-2 ENLARGED BUILDING PLAN j s ^•^^-•• B 01/21/22 ISSUED FOR REVIEW A-3 ANTENNA PLAN, ELEVATION AND SCHEDULE ItY -RE 0 01/03/23 ISSUED FOR CONSTRUCTION SOUTH A-4 NORTH AND SOUTH ELEVATIONS --- - c,mmor•m SHELDON LAKE D 01/24/23 HNAL REV A-5 EQUIPMENT PLATFORM _ A-6 EQUIPMENT AND H-FRAME DETAILS 0 a v°wee ' A-7 EQUIPMENT DETAILS SITE LOCATION ' umsuy I � A-8 PHOTO SIMS _ Village ' n0 ,•>�� complex www�s wrwms s corozr�7a(t -- A&E PROJECT NUMBER A-9 PHOTO SIMS UNDERGROUND SERVICE ALERT - ,- n .��..,. UTILITY NOTIFICATION CENTER OF COLORADO NORTH MabyArenae DNDEN00178B E-1 ELECTRICAL/FIBER ROUTE PLAN AND NOTES (800)922-1987 • -�� ® D CAMPUSWEST ® RamS Vllla e E-2 ELECTRICAL DETAILS WWW.COLORAD0811.ORG Sherpa GN 'ratan cnopslwKers DISH Wireless L.L.C. E-3 ELECTRICAL ONE-LINE, FAULT CALCS & PANEL SCHEDULE '" Nepall Restaxram® ©uw pxiren e PROJECT INFORMATION U 2 ALL WORKING OAYS TILDY NOTIFC ON PRIOR TO CONSTRUCTION g o..l 3loi mtn orex E-3.1 SERIES RATING SPECIFICATIONS C E-3.2 SITE PHOTOS R - 9 w,,.,m Qol°' DNDEN00178B G-1 GROUNDING PLANS AND NOTES ` n un 1323 WEST PLUM STREET GENERAL NOTES UNIT DISH C-2 GROUNDING DETAILS -� G-3 GROUNDING DETAILS r--- PROSPECT/ n THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE AS REQUIRED AVERyPAHn \ +„ I SHIELDS _�� •s`, FORT COLLINS, CO 80521 G-3.1 GROUNDING DETAILS FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON wvn- SHEET TITLE RE-1 RE CABLE COLOR CODE DRAINAGE. NO SANITARY SEWER SERVICE, POTABLE WATER, OR TRASH DISPOSAL IS REQUIRED AND NO COMMERCIALpfe1Jn I summit Halle GN-1 LEGEND AND ABBREVIATIONS SIGNAGE IS PROPOSED. Anw awHaa•eo TITLE SHEET GN-2 RE SIGNAGE d e•Mm as GN-3 GENERAL NOTES LAKESTRE 11"x17"PLOT WILL BE HALF SCALE UNLESS OTHERWISE NOTED .I a HOMES SHEET NUMBER GN-4 GENERAL NOTES au'"9 $ s 3 ,.,•s ° GN-5 GENERAL NOTES �-� CONTRACTOR SHALL IMMEDIATELY AL PLANS, EXISTING DIMENSIONS, AND CONDITIONS ON to ww•.v true THE JOB SITE, AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE wn�.n as wrrogm as PROCEEDING WITH THE WORK. NO SCALE DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM SEPARATION BETWEEN THE PROPOSED GPS UNIT, — TRANSMITTING ANTENNAS AND EXISTING CPS UNITS. PROPOSED DISH WIRELESS L.L.C. WEST PLUM ST WII'@I@SS,. UTILITY ROUTE 9601 S. MERIDIAN BLVD. PROPOSED DISH WIRELESS L.L.C. ENGLEWOOD, CO 80112 ACCESS ROUTE EXISTING PROPERTY ENTER PARKING — — — — — — — — — — — — LINE (TYP)� — — — — GARAGE FROM — WEST PLUM STREET I I FIELD SERVICES \\here quality still counts. .......................................................... ...� I 6335 DOWNING ST APN# 9715153001 : I DENVER, CO 80216 I SEE ENLARGED PLAN I SHEET A-z> p O O O O O 'a I 0 0 O 0000 00000 00000 0 DODO CIO 0 •�I Y o0 O 0000 00 000 0 0000 0o 00 0 0000aoo I Q I a ' 0000 o 0 � ` (� I 00 0 00 I 0 JI i I EXISTING FIBER MEET POINT •I i • • i I I I • • I • I IT IS A VIOLATION OF LAW FOR ANY PERSON, _ • UNLESS THEY ARE ACTING UNDER THE DIRECTION PR • OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. • L• I • • DRAWN BY: CHECKED BY:APPROVED BY: • YI J HW ML TA I i II II I Q I RFDS REV #: 11/2/21 i I I CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION • • A 11/29/21 ISSUED FOR REVIEW i • I I i I B 01/21/22 ISSUED FOR REVIEW C 01/03/23 ISSUED FOR CONSTRUCTION APN# 9715136001 ; I I 0 01/24/23 RNAL REV I II I I A&E PROJECT NUMBER DN N00178B DISH ...........................................................� DWireless LATO I PROJECT N I DNDEN00178B 1323 WEST PLUM STREET I I I UNIT DISH EXISTING PROPERTY FORT COLLINS, CO 80521 LINE (TYP) I SHEET TITLE APN# 9 71 51 56001 I PARCEL I I MAP SHEET NUMBER N 16' 12'8' 4'0 16' 32 A-1 .1 PARCEL MAP ImIm DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM d SEPARATION BETWEEN THE PROPOSED GPS UNIT, EXISTING TREE TRANSMITTING ANTENNAS AND EXISTING CPS UNITS. (TYR) WEST PLUM ST wirelessry A-4 ROPOSED DISH WIRELESS L.L.C. 9601 S. MERIDIAN BLVD. UTILITY ROUTE ENGLEWOOD, CO 80112 PROPOSED DISH WIRELESS L.L.C. ACCESS ROUTE .••______________________________________••.� FIELD SERVICES %%here quality still counts. EXISTING 6335 DOWNING ST MAIN ROOF �' DENVER, CO 80216 1 , 1 � 1 1 , O O O 1 00000 ' EXISTING 0 0000 00000 00000 O OOOb 000 00000 Ed MAIN ROOF 1 0000 � 0 0000 00 000 00 00 O 004 i Y 0 0 0 0 EXISTING 1 1 Q MAIN ROOF 1 EL 0 0 0 1 00 ' 0 1 U j '-6' 1 , O 1 1 EXISTING BASEMENT 1 1 ELECTRIC ROOM O 1 O , 1 1 1 1 1 `PWR PWR—PWR—PWR—PWR PWR E%ISTING TREE 1 1 FBR—FBR FBR FBI—FBR FBR (NP) IT IS A VIOLATION OF LAW FOR ANY PERSON, RISER FIBER AND POWER , UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, 1 � EXISTING FIBER TO ALTER THIS DOCUMENT. 1 L O — , MEET POINT O O 1 RISER FIBER AND POWER J 1 DRAWN BY: CHECKED BY:APPROVED BY: PROPOSED DISH WIRELESS L.L.C. RAN UNDERNEATH TOP 1 FIBER AND POWER PARKING FLOOR TO DISH 1 IN 4" RIGID CONDUIT EQUIPMENT SITE 1 HW I ML I TA 1 ATTACHED TO PARAPET WALL , 1 RFDS REV #: 11/2/21 1 1 , EXISTING EXISTING EXISTING W CONSTRUCTION PARKING 1 BUT LOT 1 UPPER PARKING 1 J DOCUMENTS 1 AREA J 1 a 1 , 1 , 1 SUBMITTALS 1 REV DATE DESCRIPTION 1 A 11/29/21 ISSUED FOR REVIEW 1 EXISTING , ACCE$$ RAMP 1 B 01/21/22 ISSUED FOR REVIEW 1 , 1 ' C 01/03/23 ISSUED FOR CONSTRUCTION 1 D 01/24/23 FINAL REV 1 � SEE BUILDING PLAN (SHEET A-2) 1 , 1 , 1 , 1 A&E PROJECT NUMBER 1 � E%ISTING EXISTING EXISTING EXISTING DNDEN00178B BUILDING BUILDING BUILDING PARKING AREA -------------- ����-�♦ DISH Wireless L.L.C. PROJECT INFORMATION EXISTING TREE (TYR) DNDEN00178B 1323 WEST PLUM STREET UNIT DISH FORT COLLINS, CO 80521 SHEET TITLE OVERALL EXISTING SITE PLAN EXISTING BUILDING BUILDING EXISTING A-4 EXISTING TREE SHEET NUMBER N BUILDING (TYP) 16' 12'8' 4'0 16' 37 �-��� OVERALL SITE PLAN DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 NOTES APPROXIMATE 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. • APPROXIMATE EXISTING EXISTING WATER 2 CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM 20" WATER LINE LOCATION SERVICE LOCATION SEPARATION BETWEEN THE PROPOSED GPS UNI. T, TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. PROPOSED DISH WIRELESS L.L.C. d sh ACCESS ROUTE APPROXIMATE APPROXIMATE EXISTING 1 EXISTING FIRE wireless SANITARY SEWER LOCATION APPROXIMATE q-4 SERVICE LOCATION EXISTING SANITARY WEST PLUM ST SERVICE LOCATION ROPOSED DISH WIRELESS L.L.C. 9601 S. MERIDIAN BLVD. UTILITY ROUTE ENGLEWOOD, CO 80112 EXISTING ELECTRIC TRANSFORMER yr FIELD SERVICES \\here quality still counts. EXISTING 6335 DOWNING ST MAIN ROOF DENVER, CO 80216 0 00 EXISTING O 0000 00000 00000 0 coo(-) 000 00000 MAIN ROOF LEI > 0 0 0 0 0 0000 00000 00 00 0 cc 0 0 APPROXIMATE QEXISTING SERVICE LOACATION 0 0 0 0 u MAINS NG RI OOF I < 00 EL 00 O 0 H- U _6. EXISTING BASEMENT O ELECTRIC ROOM O O O APPROXIMATE PWR—PWR-PWR—PWR—PWR PWR EXISTING ELECTRIC EXISTING TREE FBR-FBR-PER FBR-FBR FBR SERVICE LOCATION IT IS A VIOLATION OF LAW FOR ANY PERSON, EXIST RISER FIBER AND POWER UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. L — EXISTING FIBER RISER FIBER AND POWER MEET POINT DRAWN BY: CHECKED BY:APPROVED BY'. ❑ ❑ PROPOSED DISH WIRELESS L.L.C. RAN UNDERNEATH TOP HW ML TA FIRER AND POWER PARKING FLOOR TO DISH IN 4' RIGID CONDUIT EOUIPMENT SITE ATTACHED TO PARAPET WALL RFDS REV #: 11/2/21 EXISTING PRIVATE 8 PVC STORM DRAIN TING CONSTRUCTION EXISTING PAIRKING UPPER STING ISPARKING DOCUMENTS BUILDING LOT AREA SUBMITTALS wl REV DATE DESCRIPTION J J A 11J29J21 ISSUED FOR REVIEW EXISTING Q ACCESS RAMP B Ot/21/22 ISSUED FOR REVIEW C 01/03/23 ISSUED FOR CONSTRUCTION 0 01/24/23 FINAL REV A&E PROJECT NUMBER DNDEN00178B EXISTING EXISTING EXISTING EXISTING BUILDING BUILDING BUILDING PARKING — DISH Wireless L.L.C. AREA PROJECT INFORMATION EXISTING TREE DNDEN00178B (TYR) 1323 WEST PLUM STREET UNIT DISH FORT COLLINS, CO 80521 SHEET TITLE SUDP SITE PLAN EX ISTING 2 EXISTING BULDING EXISTING A-4 EXISTING TREE SHEET NUMBER BUILDING BUILDING N A-1.3 4' 0 1D' �° 1 OVERALL SITE PLAN DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 SEE A11111111A PLAN ALPHA SECTOR • ... ....... (SHEET A-3) PROPOSED DISH WIRELESS L.L.C. I FIBER AND POWER IN LADDERd EXISTING ..sh MAIN ROOF ■ wireless, ........... ........ .................. ....... ■. ......... ...... LA TING ......... ■ 9601 S.OMERIDIAN BLVD. ENGLEW DID, CO 80112 0 0 0 PROPOSED DISH AIN F WIRELESS L.L.C. LADDER ......71 1 00 00 000 TRAY (TYP EXISTING STAIRWAY I ACCESS I (NORTH) MEXSTIN C -0 0000 0 0 0 S CABLE LENGTH AIN ROOF 7- EXISTING A ❑ FIELE) SERVICESE U PMEN here quality Still counts. o 6335 DOWNING ST DENVER, CO 80216 SEE ENLARGED 00 EQUIPMENT PLATFORM LAYOUT (1/A-5) 6' 6 PROPOSED DISH WIRELESS PLX STING FIBER AND POWER UPPER PARKING IN 4" RIGID CONDUIT AREA INSIDE HALF WALL -I—P.R—PWR—PW —PWR—PWR—PWR— MR—PW —PWR—MR----4 — — — FIBR—F8R—FIBR—FIS —FIBR—FIBR FIBR FSR FIBR FIS —FBR FIBR L—IIT IS A VIOLATION OF LAW FOR ANY PERSON, RISER FIBER AND POWER BASEMENT S EMENT EXISTING FIBER U NLESS THEY ARE ACTING UNDER THE DIRECTION ELECTRIC ROOM MEET POINT OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. — — — — — — — — — — — — — — — — — — DRAWN BY: CHECKED -W ML EX ISTING REDS REV #: 11/2/21 UPPER PARKING AREA CONSTRUCTION DOCUMENTS J�—PROPOSED DISH WIRELESS L.L.C. SUBMITTALS EXISTING TREE (TYP.) FIBER AND POWER REV DATE DESCRIPTION IN 4" RIGID CONDUIT A 11/29/21 ISSUED FOR REVIEW o I INSIDE HALF WALL R 01/21/22 ISSUED FOR REVIEW ISSUED MR CONSTRUCTION ACCESS U 01/24/23 FINAL SEE ANTENNA PLANCESS RAMP BETA AND GAMMA SECTOR (SHEET A-3) EXISTING A&E PROJECT NUMBER PARKING EXISTING WALL .... . ............... ..... DNDENOO 1 78B ■ AREA ■ a ■ — — — ■ DISH Wireless L.L.C. PROJECT INFORMATION EXISTING ■ STAIRWAY EXISTING TREE DNDE 00178B �N By��APPR APPROVED BY: OV TA DATE DESCRIPTION " '" ISSUED C 'PT'O "29 21 'ED FOR R EW 0"'�"22 KSUM FOR REMM 01'.5�'23 "SUED FOR CONSTRUCTION 01'2"�2' P_R_ ACCESS (SOUTH) 1323 WEST PLUM STREET ■ ■ UNIT DISH FORT COLLINS, CO 80521 SHEET TITLE • ENLARGED BUILDING ............ PLAN SHEET NUMBER ENLARGED BUILDING PLAN ------------------------- A-2 DISH Wireless L.L.C. TEMPLATE VERSION 34 06/11/2021 NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. �QO PROPOSED DISH WIRELESS L.L.C.ANTENNA d (TYR 1 PER SECTOR,TOTAL 3) 2. ANTENNA AND MW DISH SPECIFICATIONS REFER TO ,A ANTENNA SCHEDULE AND TO FINAL CONSTRUCTION REDS FOR ALL RF DETAILS wirelessry 1�000 PROPOSED DISH WIRELESS L.L.C. 5G PROPOSED RRH (TYR 1 PER SECTOR, TOTAL 3) _j MT-222L MOUNT ANTENNA TRANSMISSION CABLE 9601 S. MERIDIAN BLVD. PROPOSED DISH WIRELESS L.L.C. RRH SECTOR POSITION ENGLEWOOD, CO 80112 (TYP 1 PER SECTOR, TOTAL 3) EXISTING MANUFACTURER - MODEL TECHNOLOGY SIZE (HxW) AZMUITH RAD FEED LINE TYPE PROPOSEDD NUMBER CENTER AND LENGTH ALPHA Al PROPOSED JMA - MX08FR0665-21 5G 72" x 20" 20' 65' (2) CABLES (120' LONG) 4'-11" BETA B, PROPOSED JMA - MX08FRO665-21 5G 72" x 20" 130' 65' (2) CABLES (120' LONG) GAMMA Cl PROPOSED JMA - MX08FR0665-21 5G 72" x 20" 250' 65' (2) CABLES (120' LONG) pw COAX JUMPERS ATTACHED �+ + + + + TO PARAPET TO ANTENNA STRUCTURAL NOTE: (RE:A-7/DET 9) + + + + PER MOUNT ANALYSIS BY WYCO/COWERS FIELD S E R V 1 C E S UNISTRUT MOUNTS OYP.) DATED 12/l/22 -ALL PROPOSED \\here quality still counts. ANTENNAS HAVE BEEN ASSUMED TO BE INSTALLED ON 72" LONG 2"DIA.SCH40 RRH NOTES PROPOSED DISH WIRELESS L.L.C. PIPE.WITH COMMSCOPE MT-222L WALL SECTOR POSITION MANUFACTURER - MODEL 6335 DOWNING ST POWER AND FIBER CABLES MOUNT BRACKET. CONNECT TO EXISTING TECHNOLOGY DENVER, CO 80216 PARAPET WALL WITH 4 NUMBER 1. CONTRACTOR TO REFER TO FINAL CONSTRUCTION REDS FOR ALL RE ROUTED IN PROPOSED LADDER ANCHOR AND HY270(HILTI�ADHESIVE, MIN. DETAILS. TRAY(TYP. 2 PER SECTOR, TOTAL 6) 2.75'EMBEDMENT.THE PROPOSED Al FUJITSU-TA8025-B604 SG ANTENNA SUPPORT MOUNT IS SUFFICIENT ALPHA 2. ANTENNA AND RRH MODELS MAY CHANGE DUE TO EQUIPMENT EXISTING FOR THE FINAL LOADING CONFIGURATION. Al FUJITSU-TA8025-B605 5G AVAILABILITY. ALL EQUIPMENT CHANGES MUST BE APPROVED AND STAIRWAY REMAIN IN COMPLIANCE WITH THE PROPOSED DESIGN AND PROPOSED DISH WIRELESS L.L.C. OVP ACCESS Bl FUJITSU-TA8025-B604 SG STRUCTURAL ANALYSES. DEVICE (TYP 1 PER SECTOR, TOTAL 3) (NORTH) BETA B1 FUJITSU—TAB025—B605 5G Cl FUJITSU—TA8025—B604 SG GAMMA C1 FUJITSU—TA8025—B605 SG I I N 12"6" 0 1• 2' 3' 4' S' ANTENNA PLAN — ALPHA SECTOR ANTENNA SCHEDULE No SCALE 2 IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY:APPROVED BY: HW I ML I TA REDS REV #: 11/2/21 CONSTRUCTION I DOCUMENTS \ SUBMITTALS REV DATE DESCRIPTION EXISTING \ A 11/29/21 ISSUED FOR REVIEW STAIRWAY PROPOSED RRUP AND ACCESS \ B 01/21/22 ISSUED FOR REVIEW p OU MOUL MR INSIDE STAIRWELL (SOUTH) \ C 01/03/23 ISSUED R CONSTRUCTION ST \ U 01/24/23 FINAL REV EXISTING WALL \ PROPOSED DISH WIRELESS L.L.C. 5G \ UNISTRUT MOUNTS (ttP.) RRH (TYP 1 PER SECTOR, TOTAL 3) A&E PROJECT NUMBER PROPOSED DISH WIRELESS L.L.C. RRH (TYP 1 PER SECTOR, TOTAL 3) DNDEN00178B }" Co.JUMPERS ATTACHED �_PROPOSED DISH WIRELESS L.L.C. SG I TO PARAPET TO ANTENNA DISH Wireless L.L.G. (RE:A-7/DET 9) RRH (TYP 1 PER SECTOR, TOTAL 3) PROJECT INFORMATION PROPOSED MT-222L MOUNT DNDEN001 78B ��\ 7 1323 WEST PLUM STREET PROPOSED UNIT DISH MT-222L MOUNT iv iv FORT COLLINS, CO 80521 MP SHEET TITLE SE j�R Ell eF ANTENNA PLAN c1 �cTOR AND SCHEDULE PROPOSED DISH WIRELESS L.L.C.ANTENNA PROPOSED DISH WIRELESS L.L.C.ANTENNA SHEET NUMBER N (lYP 1 PER SECTOR,TOTAL 3) (ryp 1 PER SECTOR,TOTAL 3) 12„6., 0 ,, 2. 3. 4. _, A-3 ANTENNA PLAN — BETA AND GAMMA SECTOR 3 DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 PROPOSED DISH WIRELESS L.L.C. NOTES ANTENNA (TYR 1 PER SECTOR, TOTAL 3) 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. PROPOSED DISH WIRELESS, LLC. PROPOSED ANTENNA EQUIPMENT AREA (SEE SHEET A-5) 2. CONTRACTOR SHALL MAINTAIN A 10'-0" MINIMUM _ TIP HEIGHT ®68' - E SEPARATION BETWEEN THE PROPOSED" MI UNIT, - TRANSMITTING ANTENNAS AND EXISTING GPS UNITS. PROPOSED DISH WIRELESS ANTENNA >-- BAD CENTER 065' - EXISTING HVAC UNITY wirelessry EXISTING ROOFTOP 9601 S. MERIDIAN BLVD. 60'-0" � 7�1 F�] ❑ 7=E] MT O I � ❑ E 1 ❑❑ L E ❑❑ STRUCTURAL NOTE: ❑ ❑ ❑ ❑ ❑ ❑ PER MOUNT ANALYSIS BY WYCO/COLLIERS DATED 12/1/22 -ALL PROPOSED ANTENNAS HAVE BEEN ASSUMED TO BE ❑ INSTALLED C 72" LONG 2"DIA.SCH40 PIPE.WITH COMMSCOPE MT-222L WALL MOUNT BRACKET. CONNECT DI EXISTING FHH1 FEEi U I FEi9E FEHI FEE—]] PARAPET WALL WITH (4) T"DIA. HILTI ANCHOR AND HY2]O HILTI ADHESIVE, MIN.2.]5"EMBEDMENT.THE PROPOSED FIELD SERVICES ❑❑ ANTENNA SUPPORT MOUNT IS SUFFICIENT EXISTING BUILDING FOR THE FINAL LOADING CONFIGURATION. \\here quality still counts. 6335 DOWNING ST ❑ DENVER, CO 80216 HUM FEIEEI FEE111 FEEEI FEE 711 FTI FET F-IF-1 P11 E]E] FE FLID L-IL-1 EE] ❑ ❑ ❑ ❑ ❑ ❑ 4'0 16' 32' BUILDING NORTH ELEVATION IS A ATION OF L w FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION 1/16"=1'-0" OF A LICENSED PROFESSIONAL ENGINEER, PROPOSED ANTENNA PROPOSED DISH WIRELESS L.L.C. TO ALTER THIS DOCUMENT. TIP HEIGHT 068' ANTENNA PROPOSED DISH WIRELESS ANTENNA (TYP 1 PER SECTOR, TOTAL 3) DRAWN BY: CHECKED BY:APPROVED BY: BAD CENTER 065' HW ME TA PROPOSED DISH WIRELESS, L-C. EQUIPMENT AREA IREV #: 11/2/21 EXISTING ROOFTOP ❑❑ CONSTRUCTION 60'-0" ❑ DOCUMENTS ❑❑ SUBMITTALS PROPOSED DISH WIRELESS L.L.C. REV DATE DESCRIPTION (2) 2" CONDUITS TO ROOF A 11/29/21 ISSUED FOR REVIEW ❑ ❑ B❑ 01/21/22 ISSUED FOR REWEW FO ❑❑ C 01/03/23 ISSUED R CONSTRUCTION 0❑ ❑ ❑ D 1/24/23 FNAL REV ❑❑ ❑ ❑ A&E PROJECT NUMBER DNDEN00178B b FEEE E%ISTING BUILDING DISH Wireless L.L.C. PROJECT INFORMATION DNDEN00178B 1323 WEST PLUM STREET UNIT DISH FORT COLLINS, CO 80521 FEE] SHEJ I NORTH & SOUTH ELEVATIONS SHEET NUMBER 16' ,2'8' 4'0 16' - A-4.1 BUILDING SOUTH ELEVATION -------- Z DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 NOTE STRUCTURAL NOTE: PROPOSED 1. EQUIPMENT CABINET OMITTED FOR CLARITY PER STRUCTURAL ANALYSIS BY DISH WIRELESS L.L.C. CPS COLLIERS/WYCO DATED 2 UNIT d - THE ROOF HAS SUFFICIENTCIENT CAPACITY TO SUPPORT THE DISHP LATFORM ONCE PLACED IN THE LOCATION INDICATED ON A-2. *0 � 7'-Q� ,2'-Q� wirelessry i EQUIPMENT PLATFORM CLEARANCE 1._0. 2._0., 1•-2., 2'-9" F_______________D ��-------------�J 9601 S. MERIDIAN BLVD. ENGLEWOOD, CO 80112 PROPOSED DISH WIRELESS y F — — - L.L.C. GENERATOR PLUG LJ El PROPOSED DISH WIRELESS II I PROPOSED DISH L.L.C. CPS UNIT Io PROPOSED SUB METER WIRELESS L.L.C. POWER I 'I DISH WIRELESS rn - PROTECTIVE I 'I ry L.L.C. a - CABINET EQUIPMENT CABINET �� m PROPOSED DISH WIRELESS _J o L.L.C. EQUIPMENT H-FRAME r PROPOSED DISH WIRELESS B L.L.C. "-FRAME V 3 ZEE FIELD SERVICES (F15ROPI7S-EGE-1 11 \\here quality still counts. N w z 1 pISH WIRELES�I I RIGID METAL m 1 L.L.C.`SAFETY I.I CONDUIT 6335 DOWNING ST s ll I SWITCH. I;0 DENVER, CO 80216 PROPOSED DISH WIRELESS ILI-11 INSTALL IF IN L.L.C. POWER PROTECTIVE II w (REQUIRED BYII - - CABINET 11ILOCAL UTILITY I I II IILI;QMP�BY Jfl PROPOSED DISH WIRELESS L.L.C. ZAYO FIBER ENCLOSURE `� \ o PROPOSED DISH WIRELESS L.L.C. FIBER NID, IF REQUIRED III II jll jj a o a PVC CONDUIT (TYP) PIr 000 >e e 0000000o e e PROPOSED DISH WIRELESS e e 1 m e L.L.C. EQUIPMENT PLATFORM �P PROPOSED DISH WIRELESS GROUND L.L.C. EQUIPMENT PLATFORM BUSS ROOF 00 BAR 00 UTILITY RUBBER AT EQUIPMENT PLATFORM FOOTPAD (TYR) NOTE: SUB METER TO BE FRONT ELEVATION INSTALLED BY AC PANEL. IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, 12"9" 6" 3" 0 1' 2' TO ALTER THIS DOCUMENT. PLATFORM EQUIPMENT AND SCREEN WALL PLAN 1"=1'-0" PROPOSED DISH WIRELESS DRAWN BY: CHECKED BY:APPROVED BY: L.L.C. GPS UNIT HW I ME I TA COMMSCOPE MTC4045LP -_- --- -- REDS REV 5X7 PLATFORM i� �� # t /z/z CONSTRUCTION DIMENSIONS (HxWxD) 16"x64"x6Q" II PROPOSED DISH 1 DOCUMENTS TOTAL WEIGHT 423 LBS li WIRELESS L.L.C. FIBER NID, IF II REQUIRED 0 0 SUBMITTALS nn 1 M GCOTTO PROVIDE E%TENDED �j �i j:z pz P REV DATE DESCRIPTION THREAD FOR PLATFORM IF II =i =i§-i. REQUIRED HEIGHT E%CEEDS 17" o all -i -�`r-g I1y A t V2e/21 155uED FOR REVIEW II 'r-i v=L -i- f B 01/21/22 ISSUED FOR REVIEW PLAN II `Tr-z.r_z d v1 C 01/03/23 ISSUED FOR CONSTRUCTION SIDE — 5' LENGTH BAR U 01/24/23 HNAL REM GRATING - 0tm` T N 1 EQUIPMENT - EQUIPMENT A&E PROJECT NUMBER PLATFORM PLATFORM PROPOSED DNDEN00178B FOOTPAD (NP) 0o FOOTPAD DISH WIRELESS I I Ili L.L.C. ZAYO I 12'. (TYP) FIBER - o II BAR GRATING ENCLOSURE I I - - ® DISH Wireless L.L.C. — PROJECT INFORMATION CHANNEL (TYP) SIDE - 7' LENGTH BAR v DNDEN00178B B� a o%o%% 80 1323 WEST PLUM STREET GRATING o0000 0 PROPOSED DISH WIRELESS o o L.L.C. EQUIPMENT PLATFORM UNIT DISH PVC CORD IT ( P) FORT COLLINS, CO 80521 IT ill """' N II PVC CONDUIT (TYP) SHEET TITLE EQUIPMENT L_J PLATFORM �� RooF FOOTPAD EQUIPMENT PLATFORM AND 6'-0" UTILITY UBBER MAT(TYR> SCREEN WALL DETAILS 12 R 7'-0" � EQUIPMENT PLATFORM FOOTPAD (TYP) SHEET NUMBER BACK ELEVATION A-5 12"9" 6" 3" 0 1' PLATFORM DETAIL NO SCALE 2 H-FRAME EQUIPMENT ELEVATION J "=1'-0" DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 CHARLES INDUSTRY CHARLES CFIT—PF2020DSH1 RAYCAP RDIAC-6512—P-240—MTS PM639155N4 HEX CABINET \ FIBER TELCO ENCLOSURE MANUAL TRANSFER SWITCH DIMENSIONS (HxWxD): 74"x32"x32" \ ENCLOSURE DIMS (HxW%D) 20"x2O"x9" ENCLOSURE DIM (HxWxD) 40"x20"x10" ' POWER PLANT: 48VDC ABB \ ENCLOSURE WEIGHT 20 Its TOTAL WEIGHT (EMPTY) 124 LBS HVAC 6000W DC MOUNTING WALL OPERATING AC VOLTAGE 240/120 1 PHASE 3W=G TOTAL WEIGHT (408 LBS. empty) 876.10 LBS (fully loaded) PLAN COMPLIANCE TYPE 4 ENCLOSURE RATING ENCLOSURE RATING PLAN wirelessry FRONT 0 0 0 0 9601 S. MERIDIAN BLVD. O o o O ENGLEWOOD, CO 80112 0 0 O O L O O 0 0 ° ® \%FIELD SERVICES H Ihere quality still counts. 0 ,0 0 0 D o D 6335 DOWNING ST DENVER, CO 80216 SIDE BACK SIDE FRONT SIDE BACK FRONT BACK SIDE FRONT CABINET DETAIL NQ SCALE FIBER TELCO ENCLOSURE DETAIL NO SCALE 2 MANUAL TRANSFER SWITCH DETAIL NQ SCALE 3 PCTEL MOUNTING BOLT MOUNTED IN GPSGL—TMG—SPI-40NCB MOUNTING PLATE OF RRH (TYR) MINIMUM OF 75% OR DIMENSIONS (DII MM/INCH 81 x184mm 0 270' IN ANY DIRECTION CLAMPING NUT WITH REGULAR 3.2•'x7.25" SPRING OR APPROVED EQUAL (TYR) WEIGHT W/ACCESSORIES 075 Ibs GPS CONNECTOR N—FEMALE TOP EXISTING WALL FREQUENCY RANGE 1590 f 30MHz EPDXY CAPSULE OR APPROVED EQUAL BOLT 3 EXPANSION GPS UNIT OBSTRUCTIONS MUST ANCHOR OR BE BELOW 10' APPROVED EQUAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. O O UNISTRUT ON o EXISTING WALL O O DRAWN BY: CHECKED BY:APPROVED BY: MOUNTING PLATE HW I ML I TA RRU/OVP 0 O RFDS REV #: 11/2/21 EQUIPMENT BACK CONSTRUCTION DOCUMENTS RRHZOVP UNISTRUT WALL MOUNT DETAIL No scALE 4 GPS DETAIL No SCALE 5 GPS MINIMUM SKY VIEW REQUIREMENTS No SCALE 6 SUBMITTALS REV DATE DESCRIPTION NOTE: A 11/29/21 ISSUED FOR REVIEW 1.7s•'m COMMSCOPE MTC4045HFLD OR DISH w"see L.L.C. B 01/21/22 ISSUED FOR REVIEW T1.60"O H—FRAME APPROVEDEQUIVALENTC 01/03/23 ISSUED FOR CONSTRDCTIONUNISTRUT/SUPPORT RAILS QTY 5 60" D 01/24/23 FlNAL REV WEIGHT 59.74 IbsPIPE CAPA&E PROJECT NUMBER F4' S WELDMENT PIPE DNDEN00178B a CUI2PSM6P4XXX CUI2PSM9P6XXX DISH Wireless L.L.C. (4 AWG CONDUCTORS) (6 AWG CONDUCTORS) PROJECT INFORMATION DNDEN00178B 1.41"0 SUPPORT RAIL 1323 WEST PLUM STREET 0 u, UNIT DISH GALV. U—BOLTS FORT COLLINS, CO 80521 SHEET TITLE a z . EQUIPMENT AND FNO2 M'NLIEH—FRAME DETAILS CUI2PSM9P8XXX BASE PLATE SHEET NUMBER (8 AWG CONDUCTORS) SIDE FRONT A-6 CABLES UNLIMITED HYBRID CABLE NO SCALE ] H—FRAME DETAIL No SCALE 8 NOT USED NO SCALE 9 MINIMUM BEND RADIUSES DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 FUJITSU DUAL BAND FUJITSU TRIPLE BAND RAYCAP RDIDC-3045—PF-48 _ TA08025—B604 TA08025—B605 SURGE PROTECTION DEVICE (OVP) DIMENSIONS (HxWxD) 14.9"x15.7"x7.8" DIMENSIONS (HxWxD) 14.9"x15.7"x9" DIMENSIONS (HxWxD) 16.58" x 14.58" x 8.46" WEIGHT 63.9 Ibs WEIGHT 74.95 Ibs WEIGHT 21.85 LBS 4.3-10 RE 4.3-10 RE CONNECTOR TYPE CONNECTOR CONNECTOR TYPE CONNECTOR PLAN wirelessry POWER SUPPLY DC —58--36V PLAN POWER SUPPLY DC —58--36V PLAN r- 0 9601 S. MERIDIAN BLVD. Cl ENGLEWOOD, CO 80112 CE o FIELD SERVICES BACK SIDE FRONT BACK SIDE FRONT \\here quality still counts. 6335 DOWNING ST DENVER, CO 80216 SIDE BACK FRONT RRH DETAIL NO SCALE RRH DETAIL NO SCALE 2 SURGE PROTECTION DEVICE DETAIL (OVP) No SCALE 3 L—CLAMP MOUNTING JMA WIRELESS M04 MOUNTING BRACKET COMMSCOPE MT222L PLATES (TYR OF 2) MX08FR0665-21 ANTENNA HPA-33R—BUU—H4—K ADJUSTABLE WALL MOUNTS ANTENNA PIPE MOUNT (NOT DIMENSIONS (HxWxD) 72.0"x20.o"x8.0" WIDTH 5" STANDOFF 12" INCLUDED) TOTAL WEIGHT 54 LB PLAN DEPTH 2" DIMENSIONS (HxWxD) 10"x 7"x 12" RE PORTS, CONNECTOR TYPE 8 x 4.3-10 FEMALE WEIGHT WITH BRACKETS 55.75 LBS HEIGHT 8" MOUNTING CA. LAG SCREW BRACKET (TYR OF 4 PER TOTAL WEIGHT 1.5 Ibs BRACKET) HOUSING MATERIAL ASA/ABS/ALUMINUM ANTENNA ANTENNA PIPE MOUNI EXIS ING RADOME COLOR LIGHT GRAY (NOT INCLUDED) WALL MOUNTING L—CLAMP ' CONNECTOR 1x8—PIN DAISY CHAIN BRACKET MOUNTING PLATES (TYR OF 2) IT IS AMYARENACT -AW FOR ANY PERSON, UNLESS TH E ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, Qp Qp TO ALTER THIS DOCUMENT. O O o DRAWN BY: CHECKED BY:APPROVED BY: HW I ME I TA MOUNTING PIPE RFDS REV #: 11/2/21 NOTE: U—BOLT "�J APPROVED OR DISH W(reless EQUIVALENT CONSTRUCTION BACK SIDE FRONT PLAN FRONT SIDE DOCUMENTS ANTENNA DETAIL No SCALE 4 ANTENNA MOUNTING DETAIL No scALE 5 ADJUSTABLE WALL MOUNT DETAIL NO SCALE 6 SUBMITTALS REV DATE DESCRIPTION A 11/29/21 ISSUED FOR REVIEW UTILITY RUBBER MAT, BLACK COPE 1 B48-12SL-12-09 CABLE WALL MOUNT SUPPORT B 01/21/22 ISSUED FOR REVIEW ROOFTOP LADDER TRAY C 01/03/23 ISSUED FOR CONSTRUCTION DIMENSIONS 4'x 3'x 1/2" DIMENSIONS (H%WXL) 5.25"xl2"x12' UNISTRUT TYPE GRANGER P1 COOT D 01/2a/23 FlNAL REM WEIGHT/ VOLUME 36.5 LB AVERAGE WEIGHT 75 LB PER FOOT UNISTRUT DIMENSIONS (HxWxL) 1 5/8"x 1 5/8"x 12' WEIGHT/ VOLUME 1.85 LB PER FOOT MATERIAL 100% RECYCLE RUBBER STANDARDS NEMA VE-1 RUNG ULTIMATE LOAD CAPACITY 718.5 LB NOTES: A&E PROJECT NUMBER 1. ALL HARDWARE AND PARTS SHALL BE HOT DIPPED CABLE CLAMP OR GALVANIZED WITH LOCK WASHERS AND HEAVY HEX NUTS. APPROVED EQUAL DNDEN00178B 2. VERTICAL CABLE MOUNT: 4'-0" MAX. UNISTRUT SEPARATION 3. HORIZONTAL CABLE MOUNT: 3'-0" MAX UNISTRUT SEPARATION EMT/PVC OR ® APPROVED EQUAL DISH Wireless L.L.C. Op CABLE PROJECT INFORMATION CABLE SUPPORT DNDEN00178B ' - -- SIDE RAIL ® -- STEEL CHANNEL OR 1323 WEST PLUM STREET -- APPROVED EQUAL UNIT DISH ® SIDE RAIL WEB -- ———— -- FORT COLLINS, CO 80521 ® TOP FLANGE LJ----U SHEET TITLE ° ® BOTTOM FLANGE EQUIPMENT DETAILS EXISTING EXPANSION ANCHOR EXISTING WALL WALL OR APPROVED ° ® EQUAL SHEET NUMBER PLAN SIDE A-7 UTILITY RUBBER MAT DETAIL NO SCALE 7 ROOFTOP LADDER TRAY DETAIL NO SCALE 8 CABLE WALL MOUNT SUPPORT DETAIL NO SCALE 9 DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 d h wireless- 9601 S. MERIDIAN BLVD. ENGLEWOOD, CO 80112 FIELD SERVICES \\here quality still counts. 6335 DOWNING ST DENVER, CO 80216 I ,0 I , 'f • ^ IT IS A VIOLATION OF LAW FOR ANY PERSON, - r, -- -' • UNLESS THEY ARE ACTING UNDER THE DIRECTION r OF A LICENSED PROFESSIONAL ENGINEER, ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY:APPROVED BY: v HW ME TA RED. u S REV #: 11/2/21 - - CONSTRUCTION '�_ '� `^t�� :� - .r � .1- �lwr� I��' �, - • i - DOCUMENTS .� � {�C +'`,''!� .. ! .' r �. .. ` M � ` �. .� �..♦ SUBMITTALS r••- ••_ �-; l. . J, �. .-0*0 REV DATE DESCRIPTION A 11/29/21 ISSUED FOR REVIEW r B 01/21/22 ISSUED FOR REVIEW _ C 01/03/23 ISSUED FOR CONSTRUCTION 1 • ~ .� _ D O1/24/23 FINAL REV I _ _ A&E PROJECT NUMBER DNDEN00178B DISH Wireless L.L.C. PROJECT INFORMATION DNDEN00178B 1323 WEST PLUM STREET UNIT DISH FORT COLLINS, CO 80521 SHEET TITLE PHOTO SIMS SHEET NUMBER A-8 BUILDING SOUTH ELEVATION PHOTO SIMS NO SCALE j DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 d h wireless- 9601 S. MERIDIAN BLVD. ENGLEWOOD, CO 80112 FIELD SERVICES \\here quality still counts. 6335 DOWNING ST DENVER, CO 80216 v � _ IT IS A VIOLATION OF LAW FOR ANY PERSON, 11 UNLESS OF AT EY ARE L ENSEDACTING PROFESSIONAL t DER THE DIRECTION TO ALTER THIS DOCUMENT. I � DRAWN BY: CHECKED BY:APPROVED BY: _ HW I ME I TA 1t REDS REV #: 11/2/21 V CONSTRUCTION DOCUMENTS SUBMITTALS REV DATE DESCRIPTION +� A 11/29/21 ISSUED FOR REVIEW B 01/21/22 ISSUED FOR REVIEW C 01/03/23 ISSUED FOR CONSTRUCTION D 01/24/23 FINAL REV A&E PROJECT NUMBER DNDEN00178B DISH Wireless L.L.C. PROJECT INFORMATION DNDEN00178B 1323 WEST PLUM STREET UNIT DISH FORT COLLINS, CO 80521 SHEET TITLE PHOTO SIMS SHEET NUMBER A-9 BUILDING NORTH ELEVATION PHOTO SIMS NO SCALE j DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 LOW BANDS (N71+N26) A c 0ATIONAL — (N29) (N66+N70+H—BLOCK) HYBRID/DISCREET CABLES 3/4" TAPE WIDTHS WITH 3/4" SPACING ORANGE PURPLE -- BETA RRH GAMMA RRH LOW-BAND RRH PORT 1 PORT 2 PORT 3 JRAGE J41TPORT 2 PORT 3 PORT 4 PORT 1 PORT 2 PORT3 PORT4wireless- (600 MHz N71 BASEBAND) + + SLANT - SLANT + SLANT - SLANT SLANT SLANT + SLANT + SLANT - SLANT(850 MHz N26 BAND) + (700 MHzN29 BAND) - OPTIONAL PER MARKETREDRED RED BLUE BLUE BLUE GREEN GREEN GREEN GREEN CBRS TECH NEGATIVE SLANT PORT 9601 S. MERIDIAN BLVD. ADD FREQUENCY COLOR TO SECTOR BAND(CBRS WILL USE YELLOW BAND) (3 GHz) ON ANT/RRH ENGLEWOOD, CO 80112 ORANGEORANGE RED ORANGE BLUE BLUE ORANGE ORANGE GREEN GREEN YELLOW WHITE HITE WHITE PORT ORANGE (-) PORT ORANGE ORANGE - PORT ORANGE ORANGE - HITE - HITE ALPHA SECTOR BETA SECTOR GAMMA SECTOR FIELD SERVICES MID-BAND RRH i i REDREDJ00 BLUEBLUEGREENGREENJPURPLE ��here quality Still Counts. (AWS BANDS N66+N70) ADD FREQUENCY COLOR TO SECTOR BAND 6335 DOWNING ST(CBRSWILL USE YELLOW BANDS) RED RED ULE BLUE BLUE PURPLE PURPLE GREEN DENVER, CO 80216 HITE ^PURPLE PURPLE PURPLE PURPLE - PORT PURPLE COLOR IDENTIFIER NO SCALE LHITE HITE- PORT - PORT HYBRID/DISCREET CABLES EXAMPLE 1 EXAMPLE 2 EXAMPLE 3 CANISTER COAX#1 COAX #2 INCLUDE SECTOR BANDS BEING SUPPORTED (ALPHA) (ALPHA) ALONG WITH FREQUENCY BANDS. EXAMPLE 1 - HYBRID, OR DISCREET, SUPPORTS RED RED ALL SECTORS, BOTH LOW-BANDS AND MID-BANDS. BLUE EXAMPLE 2 - HYBRID, OR DISCREET, SUPPORTS GREEN GREEN RED CBRS ONLY, ALL SECTORS. EXAMPLE 3 - MAIN COAX WITH GROUND YELLOW MOUNTED RRHs IT IS A MOLATION OF LAW FOR ANY PERSON, FIBER JUMPERS TO RRHs LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH UNLESS ATL ERRRE ED ACTINGPROF NDERL THE DIRECTION TO ALTER THIS DOCUMENT. LOW-BAND HHR FIBER CABLES HAVE SECTOR STRIPE ONLY. RED BLUE GREEN GREEN DRAWN BY: CHECKED BY:APPROVED BY: PURPLE ORANGE ORANGE PURPLE HW I ML I TA REDS REV #: 11/2/21 POWER CABLES TO RRHs LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH LOW BAND RRH MID BAND RRH LOW-BAND RRH POWER CABLES HAVE SECTOR CONSTRUCTION STRIPE ONLY E E BLUE E E DOCUMENTS PURPLE NOT USED NO ';r•,TE '3 � SUBMITTALS REV DATE DESCRIPTION RET MOTORS AT ANTENNAS ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 ANTENNA 1 A 11/29/21 ISSUED FOR REVIEW MID BAND LOW BAND MID BAND LOW BAND MID BAND LOW BAND B 01/21/22 ISSUED FOR REVIEW SET CONTROL IS HANDLED BY THE MID-BAND N N N N N N C 01/03/23 ISSUED FOR CONSTRUCTION RRH WHEN ONE SET OF RET PORTS EXIST ON ANTENNA. D o1/24/23 FINAL REV SEPARATE NET CABLES ARE USED WHEN RED RED BLUE GREEN GREEN ANTENNA PORTS PROVIDE INPUTS FOR BOTH LOW AND MID BANDS. PURPLE ORANGE PURPLE ORANGE URPLE ORANGE A&E PROJECT NUMBER DNDEN00178B MICROWAVE RADIO LINKS FORWARD AZIMUTH OF 0-120 DEGREES FORWARD AZIMUTH OF 120-240 DEGREES FORWARD AZIMUTH OF 240-359 DEGREES PRIMARY SECONDARY PRIMARY SECONDARY PRIMARY SECONDARY DISH Wireless L.L.C. LINKS WILL HAVE A 1.5-2 INCH WHITE WRAP PROJECT INFORMATION WITH THE AZIMUTH COLOR OVERLAPPING IN THE MIDDLE. WHITE WHITE WHITE WHITE WHITE WHITE ADD ADDITIONAL SECTOR COLOR BANDS FOR DNDEN00178B EACH ADDITIONAL MW RADIO. RED RED BLUE BLUE GREEN GREEN 1323 WEST PLUM STREET MICROWAVE CABLES WILL REQUIRE P-TOUCH WHITE WHITE WHITE WHITE WHITE WHITE UNIT DISH LABELS INSIDE THE CABINET TO IDENTIFY THE RED BLUE GREEN LOCAL AND REMOTE SITE ID's. FORT COLLINS, CO 80521 WHITE WHITE WHITE SHEET TITLE RF CABLE COLOR CODE SHEET NUMBER RF-1 RF CABLE COLOR CODES NO SCALE NOT USED NO SCALE 4 DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 EXOTHERMIC CONNECTION AS ANCHOR BOLT IN INCH ABV ABOVE INT INTERIOR _ MECHANICAL CONNECTION AC ALTERNATING CURRENT LB(S) POUND(S) BUSS BAR INSULATOR - ADDL ADDITIONAL LF LINEAR FEET AFF ABOVE FINISHED FLOOR LTE LONG TERM EVOLUTION CHEMICAL ELECTROLYTIC GROUNDING SYSTEM AFG ABOVE FINISHED GRADE MAS MASONRY —__ TEST CHEMICAL ELECTROLYTIC GROUNDING SYSTEM AT AGE ABOVE GROUND LEVEL MAX MAXIMUM EXOTHERMIC WITH INSPECTION SLEEVE Q AIC AMPERAGE INTERRUPTION CAPACITY ME MACHINE BOLT wirelessry GROUNDING BAR ALUM ALUMINUM MECH MECHANICAL ALT ALTERNATE ME R MANUFACTURER GROUND ROD III--� ANT ANTENNA MGB MASTER GROUND BAR 9601 S.OMERIDIAN BLVD. TEST GROUND ROD WITH INSPECTION SLEEVE III-WT APPROX APPROXIMATE MIN MINIMUM ENGLEW OD, CO 80112 ARCH ARCHITECTURAL MISC MISCELLANEOUS SINGLE POLE SWITCH ATS AUTOMATIC TRANSFER SWITCH MTL METAL AWG AMERICAN WIRE GAUGE MTS MANUAL TRANSFER SWITCH DUPLEX RECEPTACLE BATT BATTERY MW MICROWAVE LI BLDG BUILDING NEC NATIONAL ELECTRIC CODE DUPLEX GFCI RECEPTACLE /Lll BLK BLOCK NM NEWTON METERS �I BLKG BLOCKING NO. NUMBER r FLUORESCENT LIGHTING FIXTURE (2) TWO LAMPS 48—T8 r NUMBER I F BM BEAM I � FIELD SERVICES BTC BARE TINNED COPPER CONDUCTOR FITS NOT TO SCALE here quality Still Counts. SMOKE DETECTION (DC) SD BOF BOTTOM OF FOOTING OC ON—CENTER CAB CABINET 6335 DOWNING ST OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION DENVER, CO 80216 EMERGENCY LIGHTING (DC) CANT CANTILEVERED OPTIC OPENING CHG CHARGING P/C PRECAST CONCRETE SECURITY LIGHT W/PHOTOCELL LITHONIA ALXW O CLG CEILING PCS PERSONAL COMMUNICATION SERVICES LED—1—25A400/51 K—SR4-120—PE—DDBTXD CLR CLEAR PCU PRIMARY CONTROL UNIT CHAIN LINK FENCE X X X X COL COLUMN PRO PRIMARY RADIO CABINET COMM COMMON PP POLARIZING PRESERVING WOOD/WROUGHT IRON FENCE ❑ ❑ ❑ ❑ ❑ CONC CONCRETE PSF POUNDS PER SQUARE FOOT WALL STRUCTURE CONSTR CONSTRUCTION PSI POUNDS PER SQUARE INCH LEASE AREA DBL DOUBLE PT PRESSURE TREATED DC DIRECT CURRENT PWR POWER CABINET PROPERTY LINE (PIT) DEPT DEPARTMENT DF DOUGLAS FIR SETBACKS R QUANTITY A D RADIUS ICE BRIDGE DIA DIAMETER RECT RECTIFIER DIAG DIAGONAL REF REFERENCE CABLE TRAY DIM DIMENSION REINF REINFORCEMENT WATER LINE W W W W W DWG DRAWING REQ'D REQUIRED D DOWEL UNDERGROUND POWER UGP UGP UGP UGP UGP A� EACH PET REMOTE ELECTRIC TILT UNDERGROUND TELCO UGT — UGT — UGT — UGT — UGT EC ELECTRICAL CONDUCTOR RE RADIO FREQUENCY IT IS A AOLATION OF LAW FOR ANY PERSON, RMC RIGID METALLIC CONDUIT UNLESS THEY ARE ACTING UNDER THE DIRECTION OVERHEAD POWER OHP OHP OHP OHP E. ELEVATION OF A LICENSED PROFESSIONAL ENGINEER, ELEC ELECTRICAL RRH REMOTE RADIO HEAD TO ALTER THIS DOCUMENT. OVERHEAD TELCO OHT OFT OFT OHT EMT ELECTRICAL METALLIC TUBING RRU REMOTE RADIO UNIT UNDERGROUND TELCO/POWER UGT/P UGT/P UGT/P UGT/P ENG ENGINEER RAY RACEWAY DRAWN BY: CHECKED BY:APPROVED BY: EQ EQUAL SC SCHEDULE HW ML TA ABOVE GROUND POWER AGP AGP AGP AGP AGP BHT SHEET EXP EXPANSION SAD SMART INTEGRATED ACCESS DEVICE PROS REV #: 11/2/21 ABOVE GROUND TELCO AGT AGT AGT AGT AGT EXT EXTERIOR ABOVE GROUND TELCO/POWER AGT/P AGT/P AGT/P AGT/P EW EACH WAY SIM SIMILAR FAB FABRICATION SPEC SPECIFICATION CONSTRUCTION WORKPOINT W'P' FF FINISH FLOOR SO SQUARE DOCUMENTS XX FG FINISH GRADE SS STAINLESS STEEL SECTION REFERENCE X—X FIT FACILITY INTERFACE FRAME STD STANDARD SUBMITTALS FIN FINISH(ED) STL STEEL REV DATE DESCRIPTION TEMP TEMPORARY PER FLOOR THK THICKNESS A 11/29/21 ISSUED FOR REVIEW XX FDN FOUNDATION B 01/21/22 ISSUED FOR REVIEW DETAIL REFERENCE X—X TMA TOWER MOUNTED AMPLIFIER FOC FACE OF CONCRETE TN TOE NAIL C 01/03/23 ISSUED FOR CONSTRUCTION ROM FACE OF MASONRY 0 01/24/23 FINAL REV FOS FACE OF STUD TOO TOP OF ANTENNA TOO TOP OF CURB LOW FACE OF WALL TOP TOP OF FOUNDATION FS FINISH SURFACE FT FOOT TOP TOP OF PLATE (PARAPET) TOS TOP OF STEEL CA GAUGEA&E PROJECT NUMBER FOOTING TOW TOP OF WALL DNDEN00178B GA GAUGE GEN GENERATOR TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION GFCI GROUND FAULT CIRCUIT INTERRUPTER TYR TYPICAL DISH Wireless L.L.C. OILS GLUE LAMINATED BEAM UG UNDERGROUND PROJECT INFORMATION GLV GALVANIZED ILL UNDERWRITERS LABORATORY DNDEN00178B GPS GLOBAL POSITIONING SYSTEM UNO UNLESS NOTED OTHERWISE 1323 WEST PLUM STREET GND GROUND UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM UNIT DISH GSM GLOBAL SYSTEM FOR MOBILE UPS UNITERRUPTIBLE POWER SYSTEM (DC POWER PLANT) FORT COLLINS, CO 80521 HUG HOT DIPPED GALVANIZED VIF VERIFIED IN FIELD SHEET TITLE HDR HEADER W WIDE HGR HANGER W/ WITH LEGEND AND HVAC HEAT/VENTILATION/AIR CONDITIONING WD WOOD ABBREVIATIONS HT HEIGHT WP WEATHERPROOF SHEET NUMBER IGR INTERIOR GROUND RING WT WEIGHT GN-1 LEGEND ABBREVIATIONS DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 'k -1 dIIra wireless- 9601 S. MERIDIAN BLVD. ENGLEWOOD, CO 80112 FIELD SERVICES \\here quality still counts. TransmittingAntennalsl Transmitting Antenuals] TransmittingAntenualsl ENV DOWNING ST 6335 , CO 80216 Radio frequency fields beyond this point MAY Radio frequency fields beyond this point MAY Radio frequency fields beyond this point Er0EE®the FCC Occupational exposure limit MONO the FCC Occupational exposure limit MOON the FCC Occupational exposure limit Obey all posted signs and site guidelines for Obey all posted signs and site guidelines for Obey all posted signs and site guidelines for working in radio frequency environments. working in radio frequency environments. working in radio frequency environments. Call the Dish NOC at 1-866.624,6874 Call the Dish NOC at 1-866.624.6814 Call the Dish NOC at 1-866.624,6874 prior to working beyond this point prior to working beyond this point prior to working beyond this pohtt. Site ID: Site ID: Slit ID: �r rr dw�r s hIT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. DRAWN BY: CHECKED BY:APPROVED BY: HW I ML I TA OR MATION REDS REV #: 11/2/21 INF - CONSTRUCTION DOCUMENTS SUBMITTALS This is an access point to an REV DATE DESCRIPTION A 11/29/21 ISSUED FOR REVIEW area with transmitting antennas. R 01/21/22 ISSUED FOR REVIEW C 01/03/23 I FINAL FOR CONSTRUCTION D 01/24/23 NAL REV Obey all signs and barriers beyond this point. A&E PROJECT NUMBER Call the DISH NOC at 1-866-624-6874 DNDEN00178B DISH Wireless L.L.C. PROJECT INFORMATION DNDEN00178B 1323 WEST PLUM STREET UNIT DISH Site ID: FORT COLLINS, CO 80521 ® SHEET TITLE RF SIGNAGE SHEET NUMBER GN-2 RF SIGNAGE DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021 SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: 1. NOTICE TO PROCEED - NO WORK SHALL COMMENCE PRIOR TO CONTRACTOR RECEIVING A WRITTEN NOTICE TO PROCEED 1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE DISH Wireless d L.L.C. AND TOWER OWNER NOC & THE DISH Wireless L.L.C. AND TOWER OWNER CONSTRUCTION MANAGER. CONTRACTOR:GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER:DISH Wireless L.L.C. 2. "LOOK UP' - DISH Wireless L.L.C. AND TOWER OWNER SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES TOWER OWNER:TOWER OWNER Wlre�eSSry OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE 9601 S. MERIDIAN BLVD. ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY ENGLEWOOD, CO 80112 ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR DISH Wireless L.L.C. AND DISH Wireless L.L.C. AND TOWER OWNER POO STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND .� AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. JURISDICTIONAL REQUIREMENTS. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL r[' 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING OBSERVATION OF THE FINISHED STRUCTURE ONLY. FIELD SERVICES PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. \\here quality still counts. THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN 6335 DOWNING ST AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE DENVER, CO 80216 PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND DISH Wireless L.L.C. AND TOWER OWNER STANDARDS, INCLUDING GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN RECORD. ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST 5. ALL SITE WORK TO COMPLY WITH DISH Wireless L.L.C. AND TOWER OWNER INSTALLATION STANDARDS FOR CONSTRUCTION IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO ACTIVITIES ON DISH Wireless L.L.C. AND TOWER OWNER TOWER SITE AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE POSSIBLE. AN ALTERNATIVE INSTALLATION FOR APPROVAL BY DISH Wireless L.L.C. AND TOWER OWNER PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CARRIER POC AND TOWER OWNER. AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS REGULATIONS AND LAWFUL ORDERS ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, OUT SHALL COMPLY WITH ALL APPLICCAA BLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES,ORDINANCES AND APPLICABLE REGULATIONS. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS ORDINANCES AND APPLICABLE REGULATIONS. UNLESS SPECIFICALLY STATED OTHERWISE. 8. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES INCLUDING PRIVATE LOCATES SERVICES PRIOR TO THE START NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. IT IS A AOI-kTION of LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF CONSTRUCTION. 9. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE UNLESS SPECIFICALLY STATED OTHERWISE. PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY F THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE DRAWN BY: CHECKED BY:APPROVED BY: 10. N CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR 10 ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND TOWER OWNER PRIOR PROCEEDING WITH ANY SUCH CHANGE HW ME TA UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) OF INSTALLATION. FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY REDS REV #: 11/2/21 PROCEDURES. 11. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION, BEFORE SUBMITTING BIDS, TO DETERMINE THE BEST ROUTING OF ALL 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND DISH PROJECT SPECIFICATIONS, CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. CONSTRUCTION LATEST APPROVED REVISION. DOCUMENTS 12. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF DISH Wireless L.L.C. AND TOWER OWNER THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND SUBMITTALS DISPOSED OF LEGALLY. 13. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REV DATE DESCRIPTION 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. A 11/29/21 ISSUED FOR REVIEW WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH 14. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY s 01/21/22 ISSUED FOR REVIEW THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF DISH Wireless L.L.C. AND TOWER OWNER, AND/OR LOCAL UTILITIES. BASIS. 0 01/03/23 ISSUED FOR CONSTRUCTION 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE D 01/24/23 FINAL REV REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16, THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE A&E PROJECT NUMBER APPLICATION. DNDEN00178B 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DISH Wireless L.L.C. DRAWINGS AND/OR PROJECT SPECIFICATIONS. PROJECT INFORMATION 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF DNDEN00178B REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 1323 WEST PLUM STREET 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY UNIT DISH DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. FORT COLLINS, CO 80521 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS SHEET TITLE REMOVED FROM THE EXISTING FACILITY. ANTENNAS AND RADIOS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED GENERAL NOTES LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY SHEET NUMBER BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT V N-3 BE PLACED IN ANY FILL OR EMBANKMENT. DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 CONCRETE. FOUNDATIONS, AND REINFORCING STEEL: 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL-CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE AND CONSTRUCTION SPECIFICATION FOR CAST-IN-PLACE CONCRETE. GRADE PVC CONDUIT. d *04- , 2. UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 18. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION ' PST. OCCURS OR FLEXIBILITY IS NEEDED. 3. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SET MORE THAN 90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. SCREW FITTINGS ARE NOT ACCEPTABLE. Wireless,. TEMPERATURE OF CONCRETE SHALL NOT EXCEED 90'f AT TIME OF PLACEMENT. 4. CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE 9601 S. MERIDIAN BLVD. BASED ON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A NEC. ENGLEWOOD, CO 80112 MAXIMUM WATER-TO-CEMENT RATIO (W/C) OF 0.45. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS 5. ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL (WIREMOLD SPECMATE WIREWAY). SPLICES SHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). UNLESS NOTED OTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS: 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE #4 BARS AND SMALLER 40 ksi DEVICES (i.e. POWDER-ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO r C #5 BARS AND LARGER 60 ksi ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR FIELD SERVICES 6. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT \\here quality still counts. DRAWINGS: FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. DENVENV CO ING ST DG • CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" ER, CO 80216 CONCRETE EXPOSED TO EARTH OR WEATHER: 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET • STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3 (OR BETTER) FOR • #6 BARS AND LARGER 2" EXTERIOR LOCATIONS. • #5 BARS AND SMALLER 1-1/2" 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED OR NON-CORRODING; SHALL MEET OR • CONCRETE NOT EXPOSED TO EARTH OR WEATHER: EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WE OR BETTER) FOR EXTERIOR LOCATIONS. • SLAB AND WALLS 3/4" 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED • BEAMS AND COLUMNS 1-1/2" NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 7. A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR DISH Wireless L.L.C. AND IN ACCORDANCE WITH ACI 301 SECTION 4.2.4. TOWER OWNER BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. ELECTRICAL INSTALLATION NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW 'DISH Wireless L.L.C.". FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED IT IS A VIOLATION OF LAW FOR ANY PERSON, AND TRIP HAZARDS ARE ELIMINATED. UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. DRAWN BY: CHECKED BY:APPROVED BY: 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF HW I ME I TA THE NATIONAL ELECTRICAL CODE. REDS REV #: 11/2/21 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE CONSTRUCTION RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE DOCUMENTS GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE SUBMITTALS LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR REV DATE DESCRIPTION EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. A 11/29/21 ISSUED FOR REVIEW 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE R 01/21/22 ISSUED FOR REVIEW CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT 0 01/03/23 ISSUED FOR CONSTRUCTION I D'S). D 01/24/23 FINAL REV 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. TIE WRAPS ARE NOT ALLOWED. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) A&E PROJECT NUMBER WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. DNDEN00178B 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. DISH Wireless L.L.C. PROJECT INFORMATION 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI-CONDUCTOR, TYPE SCOW CORD (#14 OR LARGER) UNLESS DNDEN00178B OTHERWISE SPECIFIED. 1323 WEST PLUM STREET 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI-CONDUCTOR, TYPE TO CABLE (#14 OR LARGER), WITH UNIT DISH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. FORT COLLINS, CO 80521 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND SHEET TITLE BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE). GENERAL NOTES 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. SHEET NUMBER 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. G -4 DISH Wireless L.L.C. TEMPLATE VERSION 34 - 06/11/2021 1, GROUNDING NOTES: 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. -- ' 2. THE CONTRACTOR SHALL PERFORM IEEE FALL—OF—POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO --- ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO wireless,. PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY 9601 S. MERIDIAN BLVD. BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE ILL APPROVED GROUNDING TYPE CONDUIT CLAMPS. ENGLEWOOD, CO 80112 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE r C OF THE GROUND BUS ARE PERMITTED. FIELD S E R V ICE S 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED \\here quality still counts. COPPER UNLESS OTHERWISE INDICATED. 6335 DOWNING ST DENVER, CO 80216 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90' BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45' BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15, APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON—ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND IT IS A NOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED OF A LICENSED PROFESSIONAL ENGINEER, THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR To ALTER THIS DOCUMENT. SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL DRAWN BY: CHECKED BY:APPROVED BY: CONDITIONS, NON—METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. Hw I ME I TA 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" REDS REV #: 11/2/21 NON—METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD—WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). CONSTRUCTION 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE DOCUMENTS TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO SUBMITTALS THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE REV DATE DESCRIPTION (FERROUS OR NONFERROUS METAL PIPING ONLY). DO NOT ATTACH GROUNDING TO FIRE SPRINKLER SYSTEM PIPES. A 11/29/21 ISSUED FOR REVIEW B 01/21/22 ISSUED FOR REVIEW C 01/03/23 ISSUED FOR CONSTRUCTION D O1/24/23 FINAL REV A&E PROJECT NUMBER DNDEN00178B DISH Wireless L.L.C. PROJECT INFORMATION DNDEN00178B 1323 WEST PLUM STREET UNIT DISH FORT COLLINS, CO 80521 SHEET TITLE GENERAL NOTES SHEET NUMBER GN-5 DISH Wireless L.L.C. TEMPLATE VERSION 34 — 06/11/2021