HomeMy WebLinkAboutVariance Requests - 11/02/2022 NORTHERNENGINEERING.COM | 970.221.4158 VARIANCE REQUEST: RUDOLPH FARM FORT COLLINS | GREELEY 1 | 1 VARIANCE REQUEST November 2, 2022 City of Fort Collins Development Review 281 N College Ave. Fort Collins, CO 80524 RE: RUDOLPH FARM PROJECT MINIMUM VERTICAL CURVE K-VALUE VARIANCE REQUEST NORTHERN PROJECT #1896-001 To whom it may concern: Northern Engineering would like to present this request for a variance for the Rudolph Farm project. General information about the project is presented below, and detailed information about the nature of this request follows. General Information The project site is located at the northeast corner of Prospect Road and I-25 in Fort Collins. The site currently is used for agriculture, and this project is slated to develop multi-use “super-pad” sites which will include, commercial, retail, and residential developments. The entire project site consists of approximately 115 acres. Prospect Road Part of the project includes widening Prospect Road at the south frontage of the property. In order to connect to the existing improvements that were installed with the new bridge across I-25, two vertical curves must be used. In order to meet all other LCUASS requirements, the K-Values on the vertical curves immediately east of the I-25 connection are slightly lower than shown in LCUASS requirements. Carriage Parkway Carriage Parkway is the primary connecting road from Prospect Rd. to the north for this proposed development. The site features very little vertical fall across it, so in order to achieve positive drainage, fill must be brought in to raise the north side of the site. As such, the connection point in Carriage Pkwy to the development immediately to the north differs in elevation. We are trying to get the high point of the road as close to the north property boundary as possible to achieve proper drainage patterns. The vertical curves needed to achieve this meet the minimum required length for the design speed of the road, but the K-values for each curve are lower than the requirement. Extending the curves out far enough to achieve required K- values would cause major challenges through the rest of the design. We would like to request a variance to the LCUASS K-value requirement for vertical curves in these two areas in order to be able to meet other LCUASS requirements and achieve optimized design. If you have any questions, please feel free to contact me directly. Sincerely, NORTHERN ENGINEERING SERVICES, INC. AUSTIN SNOW, PE Project Engineer Stormwater Alternative Compliance/Variance Application City of Fort Collins Water Utilities Engineering Section A: Engineer/Owner Information Engineer Name____________________________________________Phone___________________________ Street Address_____________________________________________________________________________ City__________________________________________State________________________Zip_____________ Owner Name______________________________________________Phone___________________________ Street Address_____________________________________________________________________________ City__________________________________________State________________________Zip_____________ Section C: Alternative Compliance/Variance Information Section B: Proposed Project Information Legal description and/or address of property____________________________________________________ Project Name______________________________________________________________________________ Project/Application Number from Development Review (i.e. FDP123456)__________________________ Description of Project_______________________________________________________________________ __________________________________________________________________________________________ Existing Use (check one): ☐ residential ☐ non-residential ☐ mixed-use ☐ vacant ground Proposed Use (check one): ☐ residential ☐ non-residential ☐ mixed-use ☐ other____________________ If non-residential or mixed use, describe in detail_______________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ State the requirement from which alternative compliance/variance is sought. (Please include applicable Drainage Criteria Manual volume, chapter and section.) What hardship prevents this site from meeting the requirement? What alternative is proposed for the site? Attach separate sheet if necessary Attach separate sheet if necessary page 2 The owner agrees to comply with the provisions of the zoning ordinance, building code and all other applicable sections of the City Code, Land Use Code, City Plan and all other laws and ordinances affecting the construction and occupancy of the proposed building that are not directly approved by this variance. The owner understands that if this variance is approved, the structure and its occupants may be more susceptible to fl ood or runoff damage as well as other adverse drainage issues. Signature of owner:_____________________________________________Date:_______________________ The engineer hereby certifi es that the above information, along with the reference plans and project descriptions is correct. Signature of engineer:___________________________________________Date:_______________________ PE STAMP If you have questions or need assistance fi lling out forms, contact Fort Collins Utilities at: Phone: 970-221-6700 · TDD 970-224-6003 Web: fcgov.com/stormwater · Email: WaterUtilitiesEng@fcgov.com UtilitiesOffice use onlyDate complete application submitted:_____________ Date of approval/denial:__________________________ Variance: ☐ approved ☐ denied Staff justifi cation/notes/conditions:_______________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ________________________________________________________________________________________ Approved by:__________________________________ Entered in UtilityFile Database? ☐ yes ☐ no FE SCONTROLIRR CONTROLIRR V.P.FES DD TRAFFICVAULT VAULTF.O. ELEC TRAFFICVAULT GAS EEEEEEEX/ / / / / / / /XFOELEC C VAULTF.O.CT C CT VAULTF.O. ELEC ELEC TC C T VAULTF.O. C ELEC ELECBRKR HYD W ELEC FO H2O ELEC ELEC util LID ELEC FESFESFES FES FE SS S D S D S SS SS SS SS SS SS SS SS SS SSSSST FOFOCTVCTVE EEEEEE E E E E FESFES HYD ELEC D D D D DD VAULTELEC VAULTELEC VAULTELEC VAULTELEC VAULTELEC ELEC F.O. ELEC FOF.O.F.O. F.O.F.O. M H2OFO M ELEC ELECELEC ELECFO VAULTF.O. VAULTF.O./ / / / / / / /FOFOFO FO FO FO FO FOWWWWWWWWWWW W W W W W W W W W W W W WWWE E E E E X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / / G G G SS SS SS S SS XG G G GCTV H2OH2O C C C W CCW E H2O W W W W W W MM C S MMM WT H2O M / / / / / / / / W SB SB SB SB WWWW W WWWW8" SS8" SS8" SSG G G GG 12" SST G G G 12" SS 12" SS 12 " S S L PE A UO L 8" W 8" W 8" W 8" W 8" W P YT F F 12 " S S 12 " S S / / / / / / / // / / / / / / / / / / / / / / / / / / / / / / // / / / / / / /GGGG G G G GWELLWELL WWWSTRE E T A VI X E N D R I V E CARRI A G E P K W Y POUDRE SCHOOL DISTRICT PROSPECT 6-12 SCHOOLS PROSPECT ROAD LAKE CANAL T R I C C A N A LSOUTHEAST FRONTAGE ROADINTERSTATE 25LOT 1 LOT 8 LOT 13 LOT 10 LOT 11 LOT 4 LOT 12 TRACT C TRACT B TRACT D TRACT A LOT 2TRACT E LOT 3 TRACT F LOT 5 TRACT H LOT 9 TRACT J TRACT I TRACT K TRACT L TRACT M TRACT N TRACT G TRACT O LOT 7 LOT 6 CONNECT TO EXISTING 8" WATER MAIN CONNECT TO EXISTING 12" WATER MAIN PROPOSED FIRE HYDRANT PROPOSED 8" WATER LINE PROPOSED 8" SANITARY LINE PROPOSED 15" SANITARY LINE (TYP.) PROPOSED 18" SANITARY LINE (TYP.) PROPOSED 8" SANITARY LINE (TYP.) CONNECT TO EXISTING 8" WATER MAIN CONNECT TO EXISTING 12" WATER MAIN PROPOSED 12" WATER LINE (TYP.) CONNECT TO EXISTING SANITARY MANHOLE EXISTING 60" GREELEY RAW WATER LINE (TYP.) PROPOSED 8" WATER LINE (TYP.) POND OUTLET 1 SEE SHEET ST6 POND OUTLET 2 SEE SHEET ST6 LAKE CANAL CULVERT A SEE SHEET LC2 LAKE CANAL CULVERT B SEE SHEET LC3 LAKE CANAL CULVERT C SEE SHEET LC3 TRIC CULVERT A SEE SHEET TRIC1 TRIC CULVERT B SEE SHEET TRIC1 STORM DRAIN C SEE SHEET ST3 STORM DRAIN E SEE SHEET ST4 CULVERT H SEE SHEET ST7 STORM DRAIN F SEE SHEET ST5 STORM DRAIN G SEE SHEET ST5 POND CULVERT 1 SEE SHEET ST7 STORM DRAIN D SEE SHEET ST4 STORM DRAIN A SEE SHEET ST1 STORM DRAIN B SEE SHEET ST2 PROPOSED NON-POTABLE IRRIGATION LINE (TYP.) CONNECT TO EXISTING CONNECT TO EXISTING 12" WATER MAIN PROPOSED NON-POTABLE PUMP HOUSE PROPOSED 8" WATER LINE (TYP.) PROPOSED REGIONAL TRAIL SANITARY LINE A2 (W) SEE SHEET SS6 SANITARY LINE A7 SEE SHEET SS8 SANITARY LINE A SEE SHEET SS3 SANITARY LINE A2 (E) SEE SHEET SS7 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT EXITING 18" SANITARY SEWER CDOT 1012 SE FRONTAGE RD, FORT COLLINS IMAGO ENTERPRISES INC. 140 PALMER DR, FORT COLLINS FOX GROVE HOA 4345 FOX GROVE DR, FORT COLLINS FOX GROVE HOA 4345 FOX GROVE DR, FORT COLLINS STORM DRAIN I SEE SHEET ST8 NATURAL RESOURCE (RAPTOR NEST) NATURAL BUFFER (RAPTOR NEST) NATURAL BUFFER (DITCH BANK) 100-YEAR BOXELDER FLOODPLAIN 100-YEAR BOXELDER FLOODPLAIN PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT BOXELDER FLOODWAY PROPOSED FIRE HYDRANT PVC ELCO WATER LINE. RLINE TO BE PLUGGED & R CDOT REQUIREMENTS. EROSION BUFFER ZONE POSED 12" ATER LINE RE END. ONNECT ST SIDE ER LINE ST SIDE. PROPOSED TEMP. FIRE HYDRANT PROPOSED 8" WATER LINE PROPOSED FIRE HYDRANT PROPOSED BLOW OFF FIRE HYDRANT FOR ELCO MAINTENANCE PROPOSED TEMP. FIRE HYDRANT The Storm G crossing in question is shown at Point A in the exhibit below. The crossing features greater (15.2") than the generally accepted 12" minimum cover over smaller diameter RCP. The Lake Canal Box Culvert (RCB) is shown at Point B in the exhibit below. The precast RCB will be designed to meet AASHTO M 273 specifications, or equivalent ASTM Standard C 1433, for vehicle traffic, to allow for less than 2-feet of cover on top. We are requesting an alternative in the minimum cover requirement at these two locations for the depths described above: 15" at Point A, and 11" at Point B. POINT A - STORM G POINT B - LAKE CANAL RCB