Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SUN COMMUNITIES - THE FOOTHILLS - FDP220005 - SUBMITTAL DOCUMENTS - ROUND 4 - PHOTOMETRIC PLAN
DRAWING INDEXPROJECT CONTACT LIST PROJECT LOCATION MAP 2 Winners Circle // Suite 102 // Albany, NY 12205 518.862.0325 / 518.862.0326 fax www.bergmannpc.com DRAWING NUMBER OWNER: -SUN COMMUNITIES -27777 FRAKLIN ROAD, SUITE 200 SOUTHFIELD, MI 48034 -CONTACT: J. MCLAREN -PHONE: 248-208-2556 -FAX: DEVELOPMENT CONSULTANT: -ATWELL, LLC -1800 PARKWAY PLACE, SUITE 700 MARIETTA, GEORGIA 30067 -CONTACT: M. VICKERS, PE -PHONE: 678-591-8236 ELECTRICAL ENGINEER: -BERGMANN / CED -3800 HORIZON BLVD SUITE 505 FEASTERVILLE-TERVOSE, PA 19053 -CONTACT: D. RUSNACK, PE -PHONE: 585-498-7887 12/20/2022 9:47:25 PMFOOTHILLS FORT COLLINS SUN COMMUNITIES 27777 FRAKLIN ROAD #200 SOUTHFIELD MI 48034 10/21/2022 G001 SHEET DESCRIPTION G001 COVER SHEET E001 LEGEND E002 SPECIFICATIONS ES200 OVERALL SITE LIGHTING PLAN (REFERENCE) ES201 SITE LIGHTING PLAN AREA A ES202 SITE LIGHTING PLAN AREA B ES203 SITE LIGHTING PLAN AREA C E601 ELECTRICAL ONE-LINE AND DETAILS E801 SCHEDULES PROJECT LOCATION SCOLLEGEAVEE TRILBY RD DATE DESCRIPTION 12/21/22 REVISION 1 XXA XP ? 52 25A 3P15A 25A 3P X X-X X X X X EQUIPMENT IDENTITY (SEE MECH EQUIPMENT ABBREVIATION LIST). EQIUPMENT NUMBER SYSTEM NUMBER (IF APPLICABLE) INDICATES PLAN & DETAIL NUMBER INDICATES DRAWING ON WHICH SECTION APPEARS INDICATES SECTION NUMBER INDICATES DRAWING ON WHICH SECTION APPEARS INDICATES MATCH LINE KEYNOTE INDICATOR REFERENCE SYMBOLS # # KEYNOTE INDICATOR - DEMOLITION REVISION CLOUD MOUNTING HEIGHTS NOTE: REFER TO ARCHITECTURAL DRAWINGS FOR ADA LOCATIONS. ALL DEVICES TO BE MOUNTED WITHIN A RANGE OF 34" TO BOTTOM OF DEVICE BACKBOX TO 48" AFF TO TOP OF DEVICE BACKBOX. PREFERRED MOUNTING HEIGHT IS 48" AFF TO TOP OF DEVICE BACKBOX. CONTRACTOR TO MOUNT AT LOWER HEIGHT WITHIN THE LISTED RANGE TO OVERCOME ANY INTERFERENCES WHERE REQUIRED. NOTE NOT ALL SYMBOLS AND ABBREVIATIONS INDICATED APPEAR ONTHESE CONTRACT DRAWINGS. INDIVIDUAL DRAWINGS MAY HAVE SHEET LEGENDS FOR UNIQUE SYMBOLS AND FOR CONVENIENCE. SR SINGLE RECEPT.120V,20A, NEMA 5-20R UNLESS NOTED OTHERWISE SPLIT DUPLEX RECEPT. QUADRUPLEX RECEPT. 120V,20A, NEMA 5-20R UNLESS NOTED OTHERWISE RECEPT ON EMERGENCY CKT (DUPLEX) ISOLATED GROUND RECEPT (DUPLEX) 240 VOLT RECEPT. EQUIPMENT PLUG RECEPT ON DROP CORD (DUPLEX SHOWN) RECEPT ON CORD REEL (DUPLEX SHOWN) FLOOR RECEPT. (DUPLEX SHOWN) SAFETY DISC. SW. (FUSED) SAFETY DISC. SW. (NON-FUSED) CONDUIT TRANSITION DOWN CONDUIT TRANSITION UP HOMERUN TO PANEL BOARD. LETTERS INDICATE PANEL NAME. ARROWS INDICATE NUMBER OF CIRCUITS. NUMBERS INDICATE CIRCUIT DESIGNATIONS IN PANEL. CONDUIT EXPOSED SURFACE RACEWAY CONDUIT STUBBED OUT CONDUIT CONCEALED ELECTRICAL SYMBOL LIST QUADRUPLEX RECEPTACLE ON EMERGENCY CIRCUIT CONDUIT CONCEALED IN WALL OR OVERHEAD. CONDUIT SHOWN WITHOUT SLASH MARKS SHALL CONTAIN 2 #12 & 1#12G CONDUCTORS IN 3/4" CONDUIT UNLESS SPECIFIC EQUIPMENT REQUIRES A DIFFERENT SIZE. CONDUIT SHOWN WITH SLASH MARKS SHALL CONTAIN 1#12 CONDUCTOR PER SLASH MARK IN 3/4" CONDUIT UNLESS THE CONDUCTOR SIZE AND CONDUIT SIZE ARE SHOWN ADJACENT TO THE SLASH MARKS. SLASH MARK INDICATORS ARE: SHORT STRAIGHT=PHASE CONDUCTOR, LONG STRAIGHT=NEUTRAL CONDUCTOR, SHORT BENT ENDED=SWITCH LEGS, LONG STRAIGHT WITH A DOT=GROUND CONDUCTOR. LPB - 2,4 SPECIAL RECEPTACLE. NEMA CONFIGURATION AND RATING AS INDICATED FUSE POWER POWER HT HEAT TRACE WIRING MULTIPLE SERVICE OUTLET MULTIPLE SERVICE FLR OUTLET MULTIOUTLET ASSEMBLY / PLUGMOLD POWER BUS DUCT WITH PLUG UN DISCONNECT (FUSED) VARIABLE FREQUENCY CONTROLLER GENERAL L OS LS A OS J VS PP LIGHT LINE WEIGHT INDICATES EXISTING ITEMS TO REMAIN OR PROVIDED BY OTHERS. HEAVY LINE WEIGHT INDICATES ITEMS TO BE PROVIDED BY E.C. HEAVY DASHED LINE INDICATES ITEMS TO BE REMOVED OR RELOCATED BY E.C. DUPLEX RECEPT.120V,20A, NEMA 5-20R UNLESS NOTED OTHERWISE "WP" - WEATHERPROOF TYPE WITH WEATHER - PROOF WHILE IN USE COVER "GFI" - GROUND FAULT INTERRUPTER, 4-6mA TYPE "AC"- ABOVE COUNTER. 6" ABOVE COUNTER TO BOTTOM OF DEVICE "UC" - UNDER COUNTER "IC"- IN CABINETRY, RECESSED RECEPTACLE "DF" - MOUNTED WITHIN DRINKING FOUNTAIN CABINETRY. COORDINATE MOUNTING HEIGHT IN FIELD USING APPROVED MANUFACTURER CUT SHEETS "C"- CEILING MOUNTED "USB" - WITH USB "USB-C" - WITH USB TYPE C "TR"- TAMPER RESISTANT "CR" - CONTROLLED RECEPTACLE EMERGENCY OFF PUSH BUTTON CONNECTION TO EQUIPMENT REFER TO EQUIPMENT SCHEDULE FOR DETAILS PIN & SLEEVE CONNECTOR / RECEPTACLEP&S ## AE UTILITY SERVICE POLE "UE"UNDERGROUND ELECTRIC "UMVE"UNDERGROUND MEDIUM VOLTAGE ELECTRIC "UT"UNDERGROUND TELEPHONE "UCOM"UNDERGROUND COMMUNICATIONS "UTV"UNDERGROUND CABLE TELEVISION (CATV OR CCTV) "UFIBR"UNDERGROUND FIBER OPTIC "AE"AERIAL ELECTRIC LINE "OHT"OVERHEAD TELEPHONE "OHE"OVERHEAD ELECTRIC GENERAL NOTES: 1.MINIMUM CIRCUIT BREAKER SIZE FOR CONDUITS SHOWN ON PLANS IS 20A, 1 POLE FOR 120VAC UNLESS OTHERWISE NOTED/SHOWN ON PLANS 2.MINIMUM BRANCH CIRCUIT WIRING SHALL BE #12 AWG. DERATE CONDUCTORS PER NEC FOR VOLTAGE DROP AND CONDUIT FILL. 3.PROVIDE GROUNDING PER NEC (ARTICLE 250). 4.PROVIDE A SEPARATE NEUTRAL CONDUCTOR FROM PANELBOARD FOR EACH BRANCH CIRCUIT. 5.CONTRACTOR SHALL COORDINATE WORK WITH ASSOCIATED TRADES. 6.CONTRACTOR SHALL PROVIDE FUSES SIZED PER MANUFACTURERS RECOMMENDATIONS FOR ALL EQUIPMENT INSTALLED WITH FUSED STARTERS OR DISCONNECTS. 7.ALL EXTERIOR PVC CONDUIT SHALL TRANSITION TO RGS CONDUIT WITHIN 18" OF FOUNDATION WALL PRIOR TO PASSING THRU THAT WALL. 8.CONTRACTOR SHALL PROVIDE RACEWAY, WIRE, CABLE AND ASSOCIATED FITTINGS ALONG WITH COMPLETE CONNECTIONS REQUIRED FOR BRANCH CIRCUITS FROM DEVICES TO FINAL OVERCURRENT DEVICE AND LOCAL CONTROL DEVICE(S) PER PROJECT SPECIFICATIONS. 9.VERIFY EXACT LOCATION OF ELECTRICAL CONNECTION POINTS IN THE FIELD. 10.PROVIDE LIGHTING CONTROLS INCLUDING DEVICE ITSELF, CONDUIT, CONDUCTORS, 0-10V WIRING, POWER PACKS, SLAVE PACKS, CONNECTORS, AND OTHER ACCESSORIES FOR A COMPLETE AND OPERATIONAL SYSTEM. S# "AIM" ADDRESSABLE INPUT MODULE "AOM" ADDRESSABLE OUTPUT CONTROL MODULE "H"HEAT DETECTION TYPE "R/F" = COMBINATION RISE/FIXED TEMPERTURE "F" = FIXED TEMPERTURE "R" = RATE OF RISE ONLY "S"SMOKE DETECTOR/SENSOR "I" = IONIZATION "P" = PHOTOELECTRIC "BR"= BEAM RECEIVER "BT"= BEAM TRANSMITTER "SS"SMOKE DETECTOR SINGLE STATION ##FIRE ALARM INDICATION DEVICE S SMOKE DETECTOR/SENSOR FOR DUCT F BELL TROUBLE CD COMBINATION HORN/VISIBLE "CD" CANDELA RATING/SETTING C CD COMBINATION SPEAKER/VISIBLE "CD" CANDELA RATING/SETTING "C" = CEILING MOUNT F H HORN ONLY S C SPEAKER ONLY - WALL MOUNT "C" CEILING MOUNT M RTS RI CD CD REMOTE ALARM INDICATING AND TEST SWITCH REMOTE INDICATOR VISIBLE ONLY (STROBE) WALL / CEILING CD - CANDELA RATING / SETTING M COMBINATION SPEAKER / VISIBLE APPLIANCE "C" CEILILNG MOUNT M CD M CD VISIBLE ONLY (STROBE) EMERGENCY WALL / CEILING CD - CANDELA RATING / SETTING CO2 CO CARBON DIOXIDE DETECTOR CARBON MONOXIDE DETECTOR CD TRACK AND TRACK LIGHT'TR1' 'T1''T1' DOCK LIGHT LIGHT ON CORD REEL LIGHT LEVEL SENSOR - TYPE DENOTED OCCUPANCY SENSOR - CEILING MOUNTED "A" - 1000 SQ. FT. COVERAGE "B" - 2000 SQ. FT. COVERAGE "C" - HALLWAY TYPE "W"- WALL MOUNTED "OS"DUAL TECHNOLOGY WALL SWITCH TYPE OCCUPANCY SENSOR "D/OS"DUAL TECHNOLOGY WALL SWITCH TYPE OCCUPANCY SENSOR WITH 0-10V DIMMING "OS1"DUAL RELAY WALL SWITCH TYPE OCCUPANCY SENSOR "OS2"INFRARED WALL SWITCH TYPE OCCUPANCY SENSOR "D"0-10V WALL SWITCH DIMMER "VS"WALL SWITCH TYPE VACANCY SENSOR "D/VS"WALL SWITCH TYPE VACANCY SENSOR WITH 0-10V DIMMING "D/S"WALL POD WITH PRESET SCENES AND 0-10V DIMMING LIGHT SWITCH 20A, 120/277V " "SINGLE POLE "K"KEY OPERATION "3"3-WAY OPERATION "LVS" LOW VOLTAGE "WP" WEATHER PROOF "4"4-WAY OPERATION "a"SWITCHING ARRANGEMENT "T"TIMER "P"PILOT LIGHT EMERGENCY BATTERY LIGHTING UNIT. WIRE AHEAD OF LOCAL SWITCHING EMERGENCY LIGHT HEADS - SINGLE HEAD AND DOUBLE HEADS EXIT SIGN LIGHT WITH EMERGENCY LIGHT HEADS. LETTERS INDICATE FIXTURE TYPE. REFER TO LUMINAIRE SCHEDULE FOR DETAILS. SHADING INDICATES NUMBER OF FACES. EXIT SIGN LIGHT - WALL, CEILING OR PENDANT MOUNTED. LETTERS INDICATE FIXTURE TYPE. REFER TO LUMINAIRE SCHEDULE FOR DETAILS. ARROWS INDICATE DIRECTION. SHADING INDICATES NUMBER OF FACES. LIGHT FIXTURE UPPER CASE LETTERS INDICATE FIXTURE TYPE. REFER TO LUMINAIRE SCHEDULE FOR DETAILS. LOWER CASE LETTERS INDICATE SWITCHING ARRANGEMENT. NUMBER INDICATES BRANCH CIRCUIT. "EM" OR SHADING INDICATES EMERGENCY LIGHTING. VACANCY SENSOR - CEILING MOUNTED "A" - 1000 SQ. FT. COVERAGE "B" - 2000 SQ. FT. COVERAGE "W"- WALL MOUNTED "PP"- POWER PACK "PC"- PHOTOCELL FOR LIGHTING CONTROL "RC" - ROOM CONTROLLER "TC"- TIME CLOCK 'X1' 'X1' LA 2a LA 2 a 2a 'X1' 'X1' LA LA 2 a EMEM ## GROUND CONNECTION - EXOTHERMIC WELD GROUND CONNECTION TO STEEL OR STRUCTURE JUNCTION BOX CEILING/WALL MOUNTED "FA" - FURNITURE POWER "FD" - FURNITURE DATA "DA" - DOOR ACTUATOR "HD" - HAND DRYER PULL BOX GROUND ROD (PLAN VIEW) LIGHTNING PROTECTION AIR TERMINAL POWER POLE LIGHTNING PROTECTION CONDUCTOR SPLICE LIGHTING ARRESTOR GROUND ROD GROUND TEST WELL BUILDING GROUND BAR LA BGB TGB P SF-1 SM LH O A SIZE PANEL 'X' 100A MLO 208/120V 3Ø,4W T TELECOM GROUND BAR CLNG J J ENCLOSED CIRCUIT BREAKER COMB. MOTOR STARTER (NON-FUSED) MAG. MOTOR STARTER OR CONTACTOR COMB. MOTOR STARTER (FUSED) MOTOR TRANSFORMER GENERATOR MEDIUM VOLTAGE DRAWOUT CIRCUIT BREAKER DRAWOUT CIRCUIT BREAKER DRAWOUT CIRCUIT BREAKER SPACE MOLDED CASE CIRCUIT BREAKER MANUAL MOTOR STARTER WITH THERMAL OVERLOAD COMBINATION STARTER WITH RESET BUTTON, HAND OPERATED ACTUATOR, AND INDICATOR LIGHT ## AMP CONTROL UNIT (PANEL) "AMP"AMPLIFIER RACK "FAA"FIRE ALARM ANNUNCIATOR "FACP"FIRE ALARM CONTROL PANEL "NAC"NOTIFICATION CIRCUIT POWER BOOSTER EXTENDER PANEL FIRE ALARM WF##INTERFACE AND SUPERVISORY DEVICES "DH" DOOR HOLDER "EOL" END OF LINE "F"MANUAL PULL STATION "WF" FLOW DETECTOR "VS"VALVE SUPERFISORY SWITCH 'Z'2 EXTERIOR WALL MOUNTED LIGHTING FIXTURE. LETTER INDICATES FIXTURE TYPE ON LIGHTING FIXTURE SCHEDULE. NUMBER INDICATES BRANCH CIRCUIT. SITE J FS SIGNAL V SS H TV TV T F ## N 1N1 NC ANNUN NCC NCM 'LA' 2 2 'Z' POLE WITH STANCHION MOUNTED LIGHT FIXTURE. LETTERS INDICATED FIXTURE TYPE ON LIGHTING FIXTURE SCHEDULE. NUMBER INDICATES BRANCH CIRCUIT. BOLLARD LIGHTING FIXTURE. LETTER INDICATE FIXTURE TYPE ON LIGHTING FIXTURE SCHEDULE. NUMBER INDICATES BRANCH CIRCUIT. SITE HUMIDISTAT THERMOSTAT CLOCK (WALL MOUNT) CCTV CAMERA NURSE CALL MASTER STATION NURSE CALL DOME LIGHT (4 LAMP) NURSE CALL ANNUNCIATOR PANEL NURSE CALL EQUIPMENT CABINET SPEAKER (WALL OR CEILING MT.) VOLUME CONTROL UNDERFLOOR RACEWAY SYSTEM CABLE TRAY. "FS" INDICATES FIRE STOP LOCATION COMBINATION TELE/DATA OUTLET BOX TWO GANG JUNCTION BOX WITH 1 " CONDUIT STUBBED TO 6" ABOVE NEAREST ACCESSIBLE CEILING, NYLON BUSHING ON CONDUIT END, AND ALL RACEWAYS. ALL CABLING, TERMINATIONS AND TESTING BY OTHERS. TELEPHONE OUTLET BOX TWO GANG JUNCTION BOX WITH 1 " CONDUIT STUBBED TO 6" ABOVE NEAREST ACCESSIBLE CEILING, NYLON BUSHING ON CONDUIT END, AND ALL RACEWAYS. ALL CABLING, TERMINATIONS AND TESTING BY OTHERS. TELEVISION OUTLET CEILING OR WALL MOUNT NURSE CALL EMERG. STATION NURSE CALL DUTY STATION NURSE CALL CODE BLUE EMERG. STATION MULTIPLE SERVICE FLR OUTLET CONDUIT SLEEVE F=FIXED, P=PAN, T=TILT, Z= ZOOM "DI"DOOR INTERLOCK "DO"ELECTRIC DOOR OPERATOR "EH"ELECTRIC HINGE "EL"ELECTRIC LATCH "ES"ELECTRIC STRIKE "MS"MOTION SENSOR FOR ACCESS CONTROL "PS"POWER SUPPLY FOR ACCESS CONTROL "RE"REQUEST TO EXIT DEVICE "R"RELAY "S"DOOR STATUS CONTACTS "ML"MEGNETIC LOCK "DC"DOOR CONTACTS "CR"CARD READER "KP"KEYPAD "WAP"WIRELESS ACCESS POINT MULTIOUTLET ASSEMBLY DATA OUTLET BOX TWO GANG JUNCTION BOX WITH 1 " CONDUIT STUBBED TO 6" ABOVE NEAREST ACCESSIBLE CEILING, NYLON BUSHING ON CONDUIT END, AND ALL RACEWAYS. ALL CABLING, TERMINATIONS AND TESTING BY OTHERS. NURSE CALL STAFF STATION NURSE CALL SINGLE PATIENT STATION NURSE CALL DUAL PATIENT STATION VFC PB ####EBDSVV2NURSE CALL PATIENT PULL STATIONP PANELBOARD / DISTRIBUTION PANEL / SWITCHBOARD. SURFACE MOUNTED, FLUSH MOUNTED CARD READER 42" AFF CLOCK HANGER OULETS 42" AFF EXIT LIGHTS - FLOOR PROXIMITY 8" AFF TO BOTTOM OF SIGN, 4" FROM FRONT EDGE OF SIGN TO DOOR FRAME. EXIT LIGHTS - WALL MOUNTED ABOVE DOORS (MAX. 96" AFF) FIRE ALARM HORN/STROBE 84" AFF FIRE ALARM PULL STATION 44" AFF LIGHT SWITCHES 42" AFF MOTOR STARTERS 72" MAX TO OPERATING HANDLE PANEL BOARDS (LIGHTING AND RECEPTACLE) 72" MAX TO TOP CIRCUIT BREAKER RECEPTACLE - TYPICAL 18" AFF (U.O.N.) SAFETY SWITCHES 72" MAX TO OPERATING HANDLE TELEPHONE - DATA OUTLET 18" AFF TELEPHONE - PAY STATION 48" AFF TELEPHONE - WALL TYPE 48" AFF (UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE TO CENTERLINE OF BOXES).ARCHD24x36Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. Drawing Number Date Issued Project Number Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:07 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON E001 LEGEND SUN COMMUNITIES 10/21/2022 016477.00 "INCHES #NUMBER &AND 'FEET 1P 1 POLE (2P, 3P, 4P ETC.) @ AT CL CENTERLINE PL PLATE Y WYE Ø PHASE Ø DIAMETER Δ DELTA A A AMPERE ABC ABOVE COUNTER AC ABOVE COUNTER AC ALTERNATING CURRENT ACLG ABOVE CEILING AF AMPERE FRAME RATING AFC ABOVE FINISH CEILING AFF ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE AFI ARC FAULT CIRCUIT INTERRUPTER AHJ ATHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AL/ALUM ALUMINUM ALT ALTERNATE AM AMMETER AMP AMPERE AMPL AMPLIFIER ANNUN ANNUNCIATOR APPROX APPROXIMATELY AQ-STAT AQUASTAT ARCH ARCHITECT, ARCHITECTURAL AS AMP SWITCH RATING AT AMP TRIP RATING ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AUX AUXILIARY AV AUDIO VISUAL AWG AMERICAN WIRE GAUGE B B/BOTTOM OF ABBREVIATIONS BAS BUILDING AUTOMATION SYSTEM BATT BATTERY BD BOARD BFC BELOW FINISHED CEILING BKR BREAKER BLDG BUILDING BMS BUILDING MANAGMENT SYSTEM BOC BOTTOM OF CONCTRETE C CAB CABINET CAT CATALOG CATV CABLE TELEVITION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVITION CKT CIRCUIT CL CURRENT LIMITING CLG CEILING CM CEILING MOUNTED CMPR COMPRESSOR CND CONDUIT COMB COMBINATION CONN CONNECTION CONST CONSTRUCTION CONT CONTINUATION OR CONTINUOUS CONT CONTIINUOUS CONV CONVECTOR CP CIRCULATION PUMP OR CONTROL PANEL CRT CATHODE-RAY TUBE CT CURRENT TRANSFORMER CTR CENTER OR COUNTER CU COPPER D DC DIRECT CURRENT DCP DOMESTIC WATER CIRCULATING PUMB DDCP DIRECT DIGITAL CONTROL PANEL DE DUAL ELEMENT DEPT DEPARTMENT DET DETAIL DIA DIAMETER DISC DISCONNECT DIST DISTRIBUTION DN DOWN DP DOUBLE POLE DPR DAMPER DS SAFETY DISCONNECT SWITCH DT DOUBLE THROW DWG DRAWING E (E)EXISTING TO REMAIN (ER)EXISTING TO BE RELOCATED EC ELECTRICAL CONTRACTOR EF EXHAUST FAN EGC EQUIPMENT GROUND CONDUCTOR ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR EMERG EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EMT ELECTRICAL METALLIC TUBING EP ELECTRICAL PHEUMATIC EPO EMERGENCY POWER OFF EQUIP EQUIPMENT ES END SWITCH ETR EXISTING TO REMAIN EUH ELECTTRIC UNIT HEATER EWC ELECTTRIC WATER COOLER EWH ELECTTRIC WATER HEATER EXH EXHAUST EXP EXPLOSION PROOF F F FUSED FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS FCU FAN CONTROL UNIT FIXT FIXTURE FLOUR FLOURESCENT FLR FLOOR FU FUSE FUDS FUSED SAFETY DISCONNECT SWITCH FVNR FULL VOLTAGE NON-REVERSING G GA GUAGE GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERATOR GFI GROUND FAULT PROTECTOR GFP GROUND FAULT PROTECTOR GND, G GROUND GRS GALVANIZED RIGID STEEL (CONDUIT) GYP BD GYPSUM BOARD H HID HIGH INTENSITY DISCHARGE HOA HANDS-OFF-AUTOMATIC SWITCH HORIZ HORIZONTAL HP HORSEPOWER HPF HIGH POWER FACTOR HT HEIGHT HTG HEATING HTR HEATER HV HIGH VOLTAGE HVAC HEATING, VENTILATION AND AIR CONDITIONING HWP HYDRONIC WATER PUMP HZ HERTZ I IC INTERRUPTER CAPACITY IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT INC INCANDESCENT IR INFRARED J J-BOX, JB JUNCTION BOX K k KIPS K-FT KIP-FOOT kcmil THOUSAND CIRCULAR MILLS (MCM) kV KILOVOLT KVA KILOVOLT-AMPHERE KVAR KILOVOLT-AMPERE REACTIVE KW KILOWATT KWH KILOWATT HOUR L LA LIGHTING ARRESTOR LF LINEAR FOOR LOC LOCATE OR LOCATION LT LIGHT LTG LIGHTING LTNG LIGHTNING LV LOW VOLTAGE M M/C MOMENTARY CONTACT mA MILLIAMPHERE MAG.S MAGNETIC STARTER MAX MAXIMUM MC MECHANICAL CONTRACTOR MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDP MAIN DISTRIBUTION PANEL MFR MANUFACTURER MFS MAIN FUSED DISCONNECT SWITCH MH MANHOLE MIC MICROPHONE MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUGS ONLY MOA MULTIOUTLET ASSEMBLY MSBD MAIN SWITCHBOARD MT MOUNT MT.C EMPTY CONDUIT MTR MOTOR, MOTORIZED MTS MANUAL TRANSFER SWITCH MV MEDIUM VOLTAGE N (N)NEW WORK N NEUTRAL N.C.NORMALLY CLOSED N.O.NORMALLY OPEN NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NF NON-FUSED NFDS NON-FUSED SAFETY DISCONNECT SWITCH NIC NOT IN CONTRACT NL NIGHT LIGHT - WIRE AHEAD OF SWITCH/CONTROL No.NUMBER NPF NORMAL POWER FACTOR NRTL NATIONALLY RECOGNIZED TESTING LABORATORY NTS NOT TO SCALE NW NORMAL WEIGHT O OC ON CENTER OCPD OVERCURRENT PROTECTION DEVICE OH OVERHEAD OL OVERLOADS P P POLE PA PUBLIC ADDRESS PB PULL BOX OR PUSH BUTTON PC PLUMBING CONTRACTOR PE PHOTO ELECTRIC CELL PED PEDESTAL PF POWER FACTOR PH PHASE PIV POST INDICATING VALVE PNL PANEL PP POWER POLE PR PAIR PRI PRIMARY PROJ PROJECTION PRV POWER ROOF VENTILATOR PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE (CONDUIT) PWR POWER Q QUAN QUANTITY R (R)REMOVE (RE)RELOCTATED EXISTING RC REMOTE CONTROL RECPT RECEPTACLE REQD REQUIRED RM ROOM RMS ROOT MEAN SQUARE RR REMOVE AND REPLACE RSC RIGID STEEL CONDUIT RTU ROOF TOP UNIT S S/N SOLID NEUTRAL S/S STOP/START PUSHBUTTONS SC SURFACE CONDUIT SD REMOTE CONTROL SEC SECONDARY SF SUPPLY FAN SHT SHEET SIM SIMILAR SP SPARE SPD SURGE PROTECTION DEVICE SPEC SPECIFICATION SPKR SPEAKER SQ. FT.SQUARE FOOT SR SURFACE RACEWAY SS STAINLESS STEEL OR SAFETY SWITCH SSW SELECTOR SWITCH ST SINGLE THROW STA STATION STD STANDARD SURF SURFACE MOUNTED SW SWITCH SWBD SWITCHBOARD SWGR SWITCHGEAR SYM SYMMETRICAL SYS SYSTEM T T-STAT THERMOSTAT TEL TELEPHONE TEL/DATA TELEPHONE/DATA TERM TERMINAL TL TWIST LOCK TR TAMPER RESISTANT TS TIME SWITCH TTB TELEPHONE TERMINAL BOARD TTC TELEPHONE TERMINAL CABINET TV TELEVISION TVSS TRANSIENT VOLT. SURGE SUPPRESSION TVTC TELEVISION TERMINAL CABINET TYP TYPICAL U UC UNDER COUNTER UE UNDERGROUND ELECTRICAL UG UNDERGROUND UGE UNDERGROUND ELECTRICAL UGT UNDERGROUND TELEPHONE UH UNIT HEATER UON UNLESS OTHERWISE NOTED UTIL UTILITY UV UNIT VENTILATOR OR ULTRAVIOLET V V VOLT V.I.F.VERIFY IN FIELD VA VOLT-AMPERES VDT VIDEO DISPLAY TERMINAL VERT VERTICAL VFC VARIABLE FREQUENCY CONTROLLER VFD VARAIBLE FREQUENCY DRIVE VM VOLTMETER VOL VOLUME W W WATT OR WIRE W/WITH W/O WITHOUT W/SF WATTS PER SQUARE FOOT WG WIRE GUARD WH WATER HEATER WP WEATHERPROOF X XFMR TRANSFORMER XFR TRANSFER Date Description 12/21/22 REVISION 1 SECTION 1 - GENERAL REQUIREMENTS A. GENERAL 1. ELECTRICAL EQUIPMENT, DEVICES, AND CONDUIT ROUTINGS ARE SHOWN ON DRAWINGS TO CONVEY SCOPE AND GENERAL ARRANGEMENT ONLY AND MAY NOT INDICATE ALL EQUIPMENT AND DEVICES REQUIRED FOR A COMPLETE SYSTEM. THE ELECTRICAL CONTRACTOR (“EC”) SHALL PROVIDE ALL REQUIRED ELECTRICAL EQUIPMENT, DEVICES, WIRE, AND CONDUIT AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. COORDINATE INSTALLATION OF ELECTRICAL SYSTEMS WITH BUILDING STRUCTURE AND OTHER UTILITIES IN FIELD. 2. EC SHALL VISIT THE JOB SITE DURING BIDDING AND BECOME FAMILIAR WITH ALL JOB CONDITIONS PRIOR TO SUBMITTING BID. NO EXTRA COMPENSATION SHALL BE PAID FOR EXTRA WORK MADE NECESSARY BY THE EC'S FAILURE TO DO SO. ALL WORK REQUIRED TO ACCOMMODATE EXISTING CONDITIONS WHETHER SHOWN ON CONTRACT DRAWINGS OR NOT SHALL BE COORDINATED AND ALL COSTS TO DO SO SHALL BE INCLUDED IN THE BIDS. EC SHALL PAY EXTRA ATTENTION TO EXISTING CONDITIONS AFFECTING REMOVAL OF EXISTING EQUIPMENT AND THE ENTRANCE OF NEW EQUIPMENT. 3. COORDINATE ELECTRICAL WORK WITH THE WORK OF OTHER TRADES SO AS TO MINIMIZE INTERFERENCES AND TO MINIMIZE INTERRUPTION OF SERVICE IN ANY AREA. 4. EC SHALL UPON COMPLETION OF EACH DAYS WORK REMOVE ALL TOOLS, MATERIALS, APPARATUS, AND RUBBISH OF ANY SORT. PREMISES SHALL BE KEPT NEAT AND ORDERLY AND IN A 'BROOM CLEAN' CONDITION. 5. WORK SHALL NOT BE COVERED OR CONCEALED UNTIL IT HAS BEEN INSPECTED, TESTED AND APPROVED. ANY WORK THAT IS COVERED OR CONCEALED PRIOR TO INSPECTION AND TESTING SHALL BE UNCOVERED, AND AFTER IT HAS BEEN INSPECTED, TESTED, AND APPROVED, SHALL BE RESTORED TO ITS ORIGINAL CONDITION AT NO ADDITIONAL COST TO THE OWNER. 6. METALLIC MATERIALS SHALL BE PROTECTED AGAINST CORROSION. EQUIPMENT ENCLOSURES SHALL BE GIVEN A RUST-INHIBITING TREATMENT AND THE STANDARD FINISH BY THE MANUFACTURER. ALUMINUM SHALL NOT BE USED IN CONTACT WITH EARTH AND, WHERE CONNECTED TO DISSIMILAR METAL, SHALL BE PROTECTED BY APPROVED FITTINGS AND TREATMENT. FERROUS METALS NOT OF CORROSION-RESISTANT STEEL SHALL BE HOT DIPPED GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123 OR ASTM A153 EXCEPT WHERE OTHER EQUIVALENT PROTECTIVE TREATMENT IS SPECIFICALLY APPROVED IN WRITING. B. NEW WORK 1. ITEMS SHOWN IN HEAVY LINE WEIGHT SHALL BE PROVIDED. ITEMS SHOWN IN LIGHT LINE WEIGHT ARE EXISTING TO REMAIN OR PROVIDED BY OTHERS. 2. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND INDICATE THE GENERAL DETAILS OF WORK INTENDED. DRAWINGS ARE NOT INCLUSIVE OF ALL ANCILLARY ITEMS REQUIRED FOR PROPER INSTALLATION. 3. COMPLETION OF PROJECT, TRANSFER MARKS TO A SET OF REPRODUCIBLE DRAWINGS AND DELIVER THIS SET OF DRAWINGS TO OWNER PRIOR TO FINAL ACCEPTANCE. 4. DRAWINGS ARE GENERALLY INDICATIVE OF WORK TO BE PROVIDED, BUT MAY NOT INDICATE ALL BENDS, FITTING, BOXES, AND COMPONENTS REQUIRED TO MEET CONDITIONS. WHERE ITEMS SHOWN ON THE DRAWINGS OR DESCRIBED ELSEWHERE ARE NOT CLEARLY UNDERSTOOD, EC SHALL CONFER WITH THE OWNER AND ENGINEER PRIOR TO BIDDING. NO ALLOWANCE WILL BE MADE FOR LACK OF INFORMATION AFTER BID IS SUBMITTED AND PROJECT IS AWARDED TO EC. 5. EC REPRESENTS IT HAS VISITED THE SITE, FAMILIARIZED ITSELF WITH THE LOCAL CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, CORRELATED ITS OBSERVATIONS WITH ALL THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, VERIFIED THE ACCURACY OF THE CONTRACT DOCUMENTS, AND IS AWARE OF THE OWNER'S INTENDED USE OF THE PROJECT AREA. ANY AREAS WHERE ADDITIONAL INFORMATION IS REQUIRED ARE TO BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER IN WRITING PRIOR TO STARTING WORK. 6. EC SHALL ENSURE ALL APPLICABLE CODES ARE FOLLOWED. 7. COMPLETE CIRCUITING IS NOT SHOWN. FIELD DETERMINE ACTUAL ROUTING FOR INSTALLATION OF NEW WORK. 8. COORDINATE WORK WITH THAT OF OTHER TRADES SO THAT WORK WILL BE PROVIDED IN THE MOST DIRECT MANNER AND SO THAT INTERFERENCES WITH CONDUITS, PIPING, DUCTS, EQUIPMENT, STRUCTURAL FEATURES, AND ALL OTHER ASPECTS OF THE WORK WILL BE AVOIDED. 9. MATERIALS AND EQUIPMENT SHALL BE PROVIDED IN ACCORDANCE WITH MANUFACTURER INSTALLATION INSTRUCTIONS. OBTAIN MANUFACTURER INSTALLATION INSTRUCTIONS PRIOR TO ROUGHING IN. VERIFY THE POSITION, LOCATION, AND MANUFACTURER REQUIREMENTS PRIOR TO ROUGHING IN. WHERE MATERIALS AND EQUIPMENT ARE FURNISHED BY OTHER TRADES FOR INSTALLATION AS WORK UNDER THIS DIVISION OR WHERE ELECTRICAL SERVICE OR UTILITY CONNECTIONS TO MATERIALS AND EQUIPMENT PROVIDED BY OTHERS IS INDICATED AS WORK OF THIS DIVISION, OBTAIN SHOP DRAWINGS AND INSTALLATION INSTRUCTIONS FROM THE RESPECTIVE CONTRACTOR PRIOR TO ROUGHING IN. DISCREPANCIES BETWEEN INSTALLATION INSTRUCTIONS AND CONTRACT DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE OWNER. 10. MATERIALS SHALL BE NEW, OF THE BEST OF THEIR RESPECTIVE KINDS, WITHOUT IMPERFECTIONS OR BLEMISHES, AND SHALL BE PROTECTED FROM THE ELEMENTS PRIOR TO INSTALLATION. 11. WORK SHALL BE INSTALLED BY MECHANICS SKILLED IN THE TRADE INVOLVED. 12. WIRE, CABLE, WIRING DEVICES, MATERIALS, AND EQUIPMENT SHALL BE PROVIDED IN SUCH A MANNER TO PRESERVE ACCESS TO EQUIPMENT. 13. DAMAGES TO FACTORY FINISHES ON MATERIALS AND EQUIPMENT SHALL BE TOUCHED UP TO MATCH ORIGINAL FINISH. 14. LOCATION OF MATERIALS AND EQUIPMENT IS APPROXIMATE AND SHALL BE COORDINATED IN FIELD WITH EXISTING INTERFERENCES. MAINTAIN PROPER CLEARANCES IN AVAILABLE SPACE AS REQUIRED BY NATIONAL ELECTRICAL CODE. 15. WHERE ITEMS OF MATERIAL OR EQUIPMENT ARE SPECIFIED BY BRAND NAME, CATALOG NUMBER, OR NAME OF MANUFACTURER, REFERENCE IS INTENDED TO BE DESCRIPTIVE, NOT RESTRICTIVE, AND IS SOLELY FOR PURPOSES OF INDICATING TYPE, QUALITY, AND APPEARANCE OF ITEM THAT WILL BE ACCEPTABLE. ENGINEER RESERVES THE RIGHT TO REJECT ITEMS BY OTHER MANUFACTURERS IF THOSE ITEMS DO NOT MEET THE PHYSICAL ATTRIBUTES OF THE MANUFACTURERS LISTED. 11. ALL DEFECTS IN MATERIAL AND EQUIPMENT SHALL BE REPORTED IMMEDIATELY TO THE OWNER. WORK INVOLVING DEFECTS SHALL NOT PROCEED UNTIL THE DEFECTS HAVE BEEN RESOLVED TO THE SATISFACTION OF THE ENGINEER. 12. POWER SUPPLY INTERRUPTIONS SHALL BE CONDUCTED ONLY WHEN AUTHORIZED IN WRITING BY THE OWNER. EC SHALL SUBMIT A WRITTEN REQUEST TO OWNER FIVE (5) DAYS IN ADVANCE INDICATING THE EXTENT AND DURATION OF THE INTERRUPTION AND HAVE THE REQUEST APPROVED BY THE OWNER IN WRITING BEFORE PERFORMING THE INTERRUPTION. INTERRUPTIONS SHALL BE COORDINATED WITH OTHER TRADES. EC SHALL PROVIDE TEMPORARY POWER AT NO ADDITIONAL COST DURING ALL INTERRUPTIONS. 13. ALL EMPTY CONDUITS SHALL HAVE A PULL CORD OF 200LB TENSILE STRENGTH PROVIDED CONTINUOUSLY THROUGH THE LENGTH OF EACH EMPTY CONDUIT WITH TWO FEET OF SLACK AT EACH END OF CONDUIT. C. SCOPE OF WORK 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT INCLUDING GENERAL AND SUPPLEMENTAL CONDITIONS AND DIVISION 1 SPECIFICATION SECTIONS APPLY TO THIS SPECIFICATION. 2. FURNISH ALL LABOR, EQUIPMENT, MATERIALS, SERVICES, TESTING, APPURTENANCES, AND PROGRAMMING REQUIRED FOR A COMPLETE AND OPERATIONAL ELECTRICAL SYSTEM IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, MANUFACTURER'S INSTRUCTIONS, AND CODES AND REGULATIONS IN FORCE. 3. PROCURE ALL PERMITS AND INSPECTIONS AND PAY FOR SAME. D. DEFINITIONS 1. WHEREVER THE WORD “PROVIDE” APPEARS ON THE DRAWINGS OR IN THE SPECIFICATIONS, IT SHALL MEAN FURNISH AND INSTALL WITH ALL REQUIRED WORK, MATERIALS, EQUIPMENT, AND APPURTENANCES. 2. WHEREVER THE WORD “FURNISH” APPEARS ON THE DRAWINGS OR IN THE SPECIFICATIONS, IT SHALL MEAN TO PURCHASE AND DELIVER TO THE INSTALLING CONTRACTORS DEVICES, EQUIPMENT, AND ACCESSORIES AS SPECIFIED. 3. WHEREVER THE WORD “INSTALL” APPEARS ON THE DRAWINGS OR IN THE SPECIFICATIONS, IT SHALL MEAN TO RECEIVE, HANDLE, INSPECT FOR PROPER CONDITION, SET, MOUNT, AND BUILD WITH ALL REQUIRED ASSOCIATED WORK MATERIALS, EQUIPMENT, AND APPURTENANCES. E. SUBMITTALS 1. SUBMIT DIGITAL COPIES OF SUBMITTALS FOR EACH TYPE OF PRODUCT. 2. SUBMIT PRODUCT DATA FOR EACH TYPE OF PRODUCT. INCLUDE RATED CAPACITIES, WEIGHTS, DIMENSIONS, FEATURES, REQUIRED CLEARANCES, AND PERFORMANCE FOR EACH TYPE OF PRODUCT. 3. SUBMIT SHOP DRAWINGS FOR EACH TYPE OF PRODUCT. INCLUDE DETAILED DIMENSIONED OUTLINE PLANS AND ELEVATIONS AND WIRING DIAGRAMS FOR POWER, CONTROL, AND SIGNAL WIRING. WIRING DIAGRAMS SHALL DIFFERENTIATE BETWEEN MANUFACTURER-INSTALLED AND FIELD-INSTALLED WIRING. F. QUALITY ASSURANCE 1. INSTALLER QUALIFICATIONS: PERSONNEL WITH THE EXPERIENCE AND CAPABILITY TO CONDUCT THE WORK INDICATED, AND WHOM IS TRAINED AND CERTIFIED BY NFPA 70E AND OSHA REGULATION 29 CFR 1910.269. 2. OBTAIN EACH TYPE OF PRODUCT THROUGH ONE SOURCE FROM A SINGLE MANUFACTURER. 3. PROVIDE PRODUCTS BY ONE OF THE MANUFACTURERS LISTED IN SECTION 2 ARTICLES HEREIN. SUBSTITUTIONS WILL NOT BE PERMITTED. 4. LISTED AND LABELED AS DEFINED BY NFPA 70, ARTICLE 100, BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, AND MARKED FOR INTENDED USE. LISTING AND LABELING AGENCY SHALL BE A NATIONALLY RECOGNIZED TESTING LABORATORY AS DEFINED BY OSHA REGULATION 1910.7. 5. COMPLY WITH LOCAL ENERGY CODE.. 6. COMPLY WITH INTERNATIONAL CODES OF THE INTERNATIONAL CODE COUNCIL. 7. COMPLY WITH NFPA 70. 8. COMPLY WITH NFPA 70E. 9. ZECOMPLY WITH ALL PERMITTING AUTHORITIES HAVING JURISDICTION. G. OPERATION AND MAINTENANCE DATA 1. SUBMIT THREE (3) BOUND MANUALS CONTAINING COMPLETE TYPE WRITTEN INSTRUCTIONS ON OPERATION, CARE, AND MAINTENANCE FOR EACH TYPE OF PRODUCT. INCLUDE THE FOLLOWING: a. MANUFACTURER'S PRODUCT DATA SHEETS. b. SPARE PARTS LISTS. c. WIRING DIAGRAMS. d. WARRANTIES. H. WARRANTY 1. SUBMIT A WRITTEN WARRANTY TO OWNER AGREEING TO REPAIR OR REPLACE PRODUCTS AND ASSOCIATED COMPONENTS THAT FAIL IN MATERIALS OR WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE. WARRANTY SHALL BE COMPREHENSIVE. NO DEDUCTIBLE SHALL BE ALLOWED FOR TRAVEL TIME, SERVICE HOURS, OR REPAIR PARTS. I. RECORD DRAWINGS 1. KEEP ONE SET OF CONTRACT DRAWINGS ASIDE AT THE SITE. MARK ALL DEVIATIONS FROM CONTRACT DRAWINGS AND ANY DATA THAT IS PERTINENT FOR COMPLETION OF DOCUMENTS. AT COMPLETION OF PROJECT, TRANSFER MARKS TO A SET OF REPRODUCIBLE DRAWINGS AND DELIVER THIS SET OF DRAWINGS TO OWNER PRIOR TO FINAL ACCEPTANCE. SECTION 2 - PRODUCTS A. GROUNDING 1. GROUND RODS: COPPER-CLAD STEEL, 3/4 INCH DIAMETER, 10 FEET 0 INCHES LONG. 2. GROUND BUS: RECTANGULAR BARS OF ANNEALED COPPER 1/4 INCH X 2 INCHES IN CROSS SECTION WITH INSULATORS. 3. GROUNDING ELECTRODE CONDUCTORS: BARE COPPER. 4. BONDING JUMPERS: BARE COPPER. 5. EQUIPMENT GROUNDING CONDUCTORS: COPPER WITH GREEN- COLORED INSULATION. 6. GROUNDING CONNECTORS: BRONZE SUITABLE FOR GROUNDING AND BONDING APPLICATIONS IN CONFIGURATIONS REQUIRED FOR PARTICULAR INSTALLATION. B. ELECTRICAL IDENTIFICATION 1. EQUIPMENT IDENTIFICATION LABELS: ENGRAVED LAMINATED ACRYLIC WITH TAPED BACKS AND DRILLED HOLES FOR SCREW MOUNTING. SCREWS SHALL BE STAINLESS STEEL. MINIMUM LETTER HEIGHT SHALL BE 3/8 INCH. 2. COLOR FOR PRINTED LEGEND: BLACK LETTERS ON WHITE FIELD. a. LEGEND: INDICATE EQUIPMENT DESIGNATION, VOLTAGE, PHASE, AND NUMBER OF WIRES. 3. UNDERGROUND-LINE WARNING TAPE: PERMANENT, BRIGHT- COLORED, CONTINUOUS-PRINTED, POLYETHYLENE TAPE NOT LESS THAN 6 INCHES WIDE BY 4 MILS THICK WITH EMBEDDED METALLIC STRIP OR CORE. C. CONDUCTORS AND CABLES 1. INSULATED CURRENT CARRYING WIRE AND GROUNDING CONDUCTORS SHALL BE COPPER AND SHALL CONFORM TO NFPA 70. 2. COPPER CONDUCTORS: COMPLY WITH NEMA WC 70/ICEA S-95-658. 3. CONDUCTOR INSULATION: COMPLY WITH NEMA WC 70/ICEA S-95-658 FOR TYPE THHN-2-THWN-2 AND TYPE XHHW-2. 4. CONDUCTORS NOT SMALLER THAN 12 AWG FOR POWER CIRCUITS. CONDUCTORS NOT SMALLER THAN 14 AWG FOR CONTROL CIRCUITS. 5. COLOR-CODING FOR PHASE AND VOLTAGE LEVEL IDENTIFICATION: USE COLORS LISTED BELOW FOR FEEDER AND BRANCH CIRCUITS. COLORS SHALL BE FACTORY APPLIED, OR FOR SIZES LARGER THAN 6 AWG, FIELD APPLIED WITH COLOR- CODING CONDUCTOR TAPE. a. COLORS FOR 120/240V CIRCUITS: • PHASE A: BLACK. • PHASE B: RED. • NEUTRAL: WHITE. • GROUND: GREEN. 6. CONDUCTOR AND CABLE METHODS SHALL CONFORM TO THE FOLLOWING: a. UNDERGROUND LOCATIONS: TYPE XHHW-2 SINGLE CONDUCTORS IN RACEWAY. D. RACEWAYS AND BOXES 1. RIGID STEEL CONDUIT: ANSI C80.1. 2. LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT: FMC WITH PVC JACKET. 3. FITTINGS FOR CONDUIT: NEMA FB 1. a. EMT FITTINGS: STEEL COMPRESSION FOR 2 INCH AND SMALLER. STEEL SET-SCREW FOR 2-1/2 INCH AND LARGER. DIE-CAST NOT PERMITTED. 4. RIGID NONMETALLIC CONDUIT: NEMA TC 2, TYPE EPC-40-PVC. a. FITTINGS: NEMA TC 3. 5. SHEET METAL OUTLET AND DEVICE BOXES: NEMA OS 1. 6. RACEWAY AND BOX METHODS SHALL CONFORM TO THE FOLLOWING: a. OUTDOOR EXPOSED LOCATIONS: RIGID STEEL CONDUIT. b. OUTDOOR BOXES, ABOVEGROUND: NEMA 250, TYPE 3R. c. UNDERGROUND LOCATIONS: RNC. d. CONNECTION TO VIBRATING EQUIPMENT (INCLUDING MOTORS AND TRANSFORMERS): LFMC MAXIMUM LENGTH 3 FEET 0 INCH. e. ENCLOSURES: NEMA 250 TYPE 1, EXCEPT USE NEMA 250 TYPE 3R IN DAMP OR WET LOCATIONS. f. MINIMUM RACEWAY SIZE: 3/4-INCH TRADE SIZE. E. WIRING DEVICES 1. DUPLEX RECEPTACLES: HEAVY DUTY SPECIFICATION GRADE RATED 120VAC, 20 AMP, NEMA 5-20R. 2. GFCI RECEPTACLES: HEAVY DUTY SPECIFICATION GRADE, WEATHER RESISTANT NON-FEED-THROUGH TYPE, DUPLEX RECEPTACLES WITH SELF-TESTING AND WR MARKING ON FACE WHEN INSTALLED. 3. FINISH: WHITE PLASTIC. 4. COVER PLATES: ONE PIECE TO SUIT WIRING DEVICES INSTALLED. OUTDOOR LOCATIONS, RECEPTACLES: NEMA 250, TYPE 3R WEATHER RESISTANT, DIE-CAST ALUMINUM WHILE-IN-USE TYPE WITH FOAM GASKET AND LOCKABLE COVER. F. PANELBOARDS 1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: a. CUTLER-HAMMER; A BRAND OF EATON. b. ABB c. SIEMENS ENERGY & AUTOMATION, INC. d. SQUARE-D; A BRAND OF SCHNEIDER ELECTRIC. 2. GENERAL REQUIREMENTS a. ENCLOSURES: NEMA 3R, TYPE 1, SURFACE-MOUNTED CABINETS. b. FINISHES: GALVANIZED STEEL BACK BOXES AND STEEL PANELS AND TRIM. c. PHASE, NEUTRAL, AND GROUND BUSES: COPPER. d. EQUIPMENT GROUND BUS: ADEQUATE FOR FEEDER AND BRANCH-CIRCUIT EQUIPMENT GROUNDING CONDUCTORS BONDED TO BOX. e. CONDUCTOR CONNECTORS: SUITABLE FOR USE WITH CONDUCTOR MATERIAL AND SIZES. f. PANELBOARD SHORT CIRCUIT RATING: FULLY RATED TO INTERRUPT SYMMETRICAL SHORT CIRCUIT CURRENT AVAILABLE AT TERMINALS. SERIES OR INTEGRATED RATINGS ARE NOT PERMITTED. 3. LIGHTING AND APPLIANCE BRANCH-CIRCUIT PANELBOARDS a. PANELBOARDS: NEMA PB 1 LIGHTING AND BRANCH-CIRCUIT TYPE. b. MAINS: CIRCUIT BREAKER UNLESS NOTED OTHERWISE. c. BRANCH OVERCURRENT PROTECTIVE DEVICES: BOLT-ON CIRCUIT BREAKERS. d. DOORS: HINGED TRIM TYPE WITH CONCEALED HINGE INNER AND OUTER DOOR, SECURED FLUSH LATCH ON INNER DOOR, TUMBLER LOCK, AND KEYED ALIKE. 4. MOLDED-CASE CIRCUIT BREAKERS: COMPLY WITH UL 489 WITH INTERRUPTING CAPACITY TO MEET AVAILABLE FAULT CURRENTS. a. THERMAL-MAGNETIC CIRCUIT BREAKERS: INVERSE TIME- CURRENT ELEMENT FOR LOW-LEVEL OVERLOADS AND INSTANTANEOUS MAGNETIC TRIP ELEMENT FOR SHORT CIRCUITS. ADJUSTABLE MAGNETIC TRIP SETTING FOR CIRCUIT-BREAKER FRAME SIZES 250 A AND LARGER. b. GFCI CIRCUIT BREAKERS: SINGLE- AND TWO-POLE CONFIGURATIONS WITH CLASS A GROUND-FAULT PROTECTION (6-MA TRIP). G. TRANSIENT VOLTAGE SUPPRESSION DEVICES a. DESCRIPTION: IEEE C62.41-COMPLIENT, INTEGRALLY MOUNTED, SOLID-STATE TYPE WITH 200KA SHORT-CIRCUIT RATING, INDIVIDUALLY FUSED SUPPRESSION MODES, AND AUDIBLE ALARM. b. PEAK SURGE CURRENT RATING: 240KA PER PHASE. c. SYSTEM VOLTAGE: VOLTAGE AS INDICATED ON DRAWINGS. d. MODES OF PROTECTION: L-L, L-N. L-G, AND N-G. e. SURGE COUNTER: DISPLAYS THE COMBINED TOTAL NUMBER OF TRANSIENT VOLTAGE SURGES DETECTED SINCE THE COUNTER WAS LAST RESET. H. LIGHTING CONTACTOR PANELS a. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING: a. GE INDUSTRIAL SYSTEMS. b. LITHONIA LIGHTING. c. LUTRON ELECTRONICS. b. DESCRIPTION: ELECTRICALLY OPERATED AND MECHANICALLY HELD, FEED-THROUGH TYPE, COMPLYING WITH NEMA ICS 2 AND UL 508. NUMBER OF RELAYS AS INDICATED ON DRAWINGS. c. RELAY RATINGS: SPST, NORMALLY OPEN, 16 AMP CONTINUOUS USE; WITH VOLTAGE RATING AS INDICATED ON DRAWINGS. QUANTITY AS INDICATED ON DRAWINGS. d. CONTROLS: SIMPLE, EASY-TO-USE MICROPROCESSOR CONTROLLER WITH LCD USER INTERFACE AND INTEGRATED ASTRONOMICAL TIME CLOCK WITH DAILY AND HOLIDAY SCHEDULES AND POWER FAILURE MEMORY. a. NETWORK CAPABILITY: THE SYSTEM SHALL BE CAPABLE OF NETWORKED OPERATION, WITH SHARED SCHEDULE AND OVERRIDES. b. SYSTEM OVERRIDE: THE SYSTEM SHALL PERMIT LIGHTING TO BE OVERRIDDEN ON FOR AFTER-HOURS USE. c. PROGRAMMING: THOUGH A LOCAL KEYPAD AND DISPLAY OR OFF-LINE THROUGH A PERSONAL COMPUTER WITH OPTIONAL CONFIGURATION SOFTWARE. e. ENCLOSURE: NEMA 3R, TYPE 1. SECTION 3 - EXECUTION A. GROUNDING 1. GROUNDING SHALL BE IN ACCORDANCE WITH NFPA 70. 2. THE NON-CURRENT CARRYING PARTS OF ALL ELECTRICAL EQUIPMENT SHALL BE BONDED TO THE EQUIPMENT GROUND SERVING THIS EQUIPMENT. 3. INSTALL A SEPARATE EQUIPMENT GROUNDING CONDUCTOR IN CONDUITS WITH ALL BRANCH CIRCUITS AND FEEDERS. SIZE EQUIPMENT GROUNDING CONDUCTORS IN ACCORDANCE WITH NFPA 70. TERMINATE EACH END ON SUITABLE LUG, BUS, OR BUSHING. 4. INSTALL SOLID CONDUCTORS FOR NO. 10 AWG AND SMALLER, AND STRANDED FOR NO. 8 AND LARGER. 5. BURY UNDERGROUND GROUNDING CONDUCTORS AT LEAST 24 INCHES BELOW GRADE. 6. PERFORM TESTS AND INSPECTIONS. a. INSPECT PHYSICAL AND MECHANICAL CONDITION. VERIFY TIGHTNESS OF ALL BOLTED CONNECTIONS WITH CALIBRATED TORQUE WRENCH ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. b. TEST GROUND RESISTANCE AT SERVICE DISCONNECT ENCLOSURE GROUNDING TERMINAL, AT GROUND TEST WELLS, AND AT INDIVIDUAL GROUND RODS. MAXIMUM MEASURED GROUND RESISTANCE SHALL NOT EXCEED 5 OHMS. c. MEASURE GROUND RESISTANCE NO FEWER THAN TWO FULL DAYS AFTER LAST TRACE OF PRECIPITATION AND WITHOUT SOIL BEING MOISTENED BY ANY MEANS. d. PREPARE AND SUBMIT TEST AND INSPECTION REPORTS. B. ELECTRICAL IDENTIFICATION 1. EQUIPMENT IDENTIFICATION LABELS: ON EACH UNIT OF EQUIPMENT, INSTALL A UNIQUE IDENTIFICATION LABEL THAT IS CONSISTENT WITH DESIGNATIONS ON CONTRACT DRAWINGS. APPLY LABELS TO SUBSTATIONS, GENERATORS, TRANSFER SWITCHES, UPS SYSTEMS, PANELBOARDS, SWITCHGEAR, TRANSFORMERS, MCC'S, DISCONNECT SWITCHES, AND STARTERS. a. UNLESS OTHERWISE INDICATED, PROVIDE SINGLE LINE OF TEXT WITH 1/2-INCH HIGH LETTERS ON 1-1/2-INCH HIGH LABELS; WHERE TWO LINES OF TEXT ARE REQUIRED, USE LABELS 1-INCHES HIGH. b. ATTACH NON-ADHESIVE IDENTIFICATION PRODUCTS WITH SCREWS AND AUXILIARY HARDWARE APPROPRIATE TO THE LOCATION AND SUBSTRATE. 2. LOCATION OF UNDERGROUND LINES: IDENTIFY WITH UNDERGROUND-LINE WARNING TAPE FOR POWER, LIGHTING, COMMUNICATION, AND CONTROL WIRING AND OPTICAL FIBER CABLE. INSTALL UNDERGROUND-LINE WARNING TAPE FOR BOTH DIRECT-BURIED CABLES AND CABLES IN RACEWAYS. 3. DURING BACKFILLING OF TRENCHES, INSTALL CONTINUOUS UNDERGROUND-LINE WARNING TAPE DIRECTLY ABOVE LINE AT 6 TO 8 INCHES BELOW FINISHED GRADE. USE MULTIPLE TAPES WHERE WIDTH OF MULTIPLE LINES INSTALLED IN A COMMON TRENCH OR CONCRETE ENVELOPE EXCEEDS 16 INCHES OVERALL. C. CONDUCTORS AND CABLES 1. INSTALL SEPARATE NEUTRAL CONDUCTOR WITH EACH 120V AND 277V BRANCH CIRCUIT. SHARED NEUTRALS ARE NOT PERMITTED. 2. CONDUITS SHALL BE COMPLETELY INSTALLED, WITH INTERIORS PROTECTED FROM WEATHER, BEFORE PROCEEDING WITH THE INSTALLATION OF CONDUCTORS AND CABLES. 3. CONDUCTORS SHALL BE CONTINUOUS WITH SPLICES AND CONNECTIONS ONLY MADE IN OUTLET, JUNCTION, OR PULL BOXES. 4. PHASE CONDUCTORS AND THE NEUTRAL CONDUCTOR OF EACH FEEDER OR BRANCH CIRCUIT SHALL BE CONTAINED IN A SINGLE CONDUIT OR PARALLELED IN SEPARATE CONDUITS TO AVOID OVERHEATING THE CONDUIT BY INDUCTION. 5. USE MANUFACTURER'S APPROVED NON-CONDUCTIVE PULLING COMPOUND OR LUBRICANT WHERE NECESSARY; COMPOUND USED MUST NOT DETERIORATE CONDUCTOR OR INSULATION. DO NOT EXCEED MANUFACTURER'S RECOMMENDED MAXIMUM PULLING TENSIONS AND SIDEWALL PRESSURE VALUES. 6. SPLICES IN CONDUCTORS NO. 8 AND SMALLER SHALL BE MADE WITH INSULATED SPRING WIRE, CONNECTORS WITH PLASTIC CAPS, OR WITH CRIMP TYPE CONNECTORS AND COMPRESSION TOOLS TO ENSURE A SATISFACTORY MECHANICAL AND ELECTRICAL JOINT. 7. SPLICES IN CONDUCTORS NO. 6 AND LARGER SHALL BE MADE WITH CRIMP-TYPE CONNECTORS AND COMPRESSION TOOLS OR WITH BOLTED CLAMP-TYPE CONNECTORS TO ENSURE A SATISFACTORY MECHANICAL AND ELECTRICAL JOINT. 8. SPLICES SHALL BE WRAPPED WITH TAPE THAT HAS AN INSULATION AND TEMPERATURE RATING EQUIVALENT TO THAT OF THE CONDUCTOR. 9. WHERE FEEDERS AND BRANCH CIRCUITS EXCEED 60 FEET (120V) OR 120 FEET (277 VOLT) TO CENTER OF LOAD, USE NO. 10 AWG WIRE TO THAT POINT. VOLTAGE DROP SHALL NOT EXCEED 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. 10. HOME RUNS MAY BE COMBINED INTO A SINGLE CONDUIT. HOWEVER, MAXIMUM NUMBER OF CONDUCTORS SHALL MEET CONDUIT FILL AND DERATING REQUIREMENTS OF NFPA 70. DERATE CONDUCTORS WHERE MULTIPLE CONDUITS ARE INSTALLED. SEPARATE NEUTRALS SHALL BE INSTALLED AND CLASSIFIED AS A CURRENT CARRYING CONDUCTOR. DIVERSITY FACTOR FOR EACH CIRCUIT IS 100 PERCENT. 11. PERFORM TESTS AND INSPECTIONS. a. PERFORM EACH ELECTRICAL TEST AND VISUAL AND MECHANICAL INSPECTION STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS. b. PREPARE AND SUBMIT TEST AND INSPECTION REPORTS. D. RACEWAYS AND BOXES 1. INSTALL NO MORE THAN THE EQUIVALENT OF THREE 90-DEGREE BENDS IN ANY CONDUIT RUN EXCEPT FOR COMMUNICATIONS CONDUITS, FOR WHICH NO MORE THAN TWO 90-DEGREE BENDS IN ANY CONDUIT RUN ARE ALLOWED. 2. RACEWAYS SHALL BE FASTENED TO BOXES WITH TWO LOCKNUTS AND A BUSHING. 3. CONDUITS SHALL BE SECURELY FASTENED WITH HOT-DIPPED GALVANIZED STEEL SUPPORTS. 4. CONDUITS SHALL BE CONTINUOUS FROM TERMINATION TO TERMINATION. 5. CONDUITS THREADED IN FIELD SHALL BE COATED WITH AN APPROVED ELECTRICALLY CONDUCTIVE, CORROSION- RESISTANT COMPOUND. E. WIRING DEVICES 1. RECEPTACLE ORIENTATION: INSTALL GROUND PIN OF VERTICALLY MOUNTED RECEPTACLES UP FOR RECEPTACLES MOUNTED 48-INCHES AND BELOW, DOWN FOR RECEPTACLES MOUNTED ABOVE 48-INCHES, AND ON HORIZONTALLY MOUNTED RECEPTACLES TO THE RIGHT. 2. DEVICE PLATES: DO NOT USE OVERSIZE OR EXTRA-DEEP PLATES. 3. PERFORM TESTS AND INSPECTIONS FOR CONVENIENCE RECEPTACLES. a. USE INSTRUMENTS THAT COMPLY WITH UL 1436. USE DIGITAL WIRNG ANALYZER WITH DIGITAL READOUT OR ILLUMINATED LED INDICATORS OF MEASUREMENTS FOR CONVENIENCE RECEPTACLES. b. TEST LINE VOLTAGE. ACCEPTABLE RANGE IS 105 TO 132 V. c. TEST PERCENT VOLTAGE DROP WITH 15-A LOAD. A VALUE ABOVE 3 PERCENT IS NOT ACCEPTABLE. d. TEST GROUND IMPEDANCE. A VALUE ABOVE 2 OHMS IS NOT ACCEPTABLE. e. TEST GFCI TRIP FOR COMPLIANCE WITH UL 1436 AND UL 943. f. VERIFY DEVICE AND ITS OUTLET BOX ARE SECURELY MOUNTED. g. PREPARE AND SUBMIT TEST AND INSPECTION REPORTS. F. PANELBOARDS 1. MOUNT ENCLOSURES WITH TOPS AT UNIFORM HEIGHT, WITH OPERATING HANDLES, MAXIMUM 72 INCHES ABOVE FINISHED FLOOR. 2. INSTALL FILLER PLATES IN UNUSED SPACES. 3. INSTALL IDENTIFICATION PLATE. 4. PROVIDE TYPED PANEL INDEX TO INDICATE INSTALLED CIRCUITS WITH A DEGREE OF DETAIL THAT ALLOWS EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. INCLUDE FOR EACH CIRCUIT INDEX THE LOAD TYPE (SUCH AS RECEPTACLES, LIGHTING, EQUIPMENT TAG, ETC.) AND LOCATION OF LOAD (SUCH AS ROOM NAME OR ROOM NUMBER). 5. PERFORM TESTS AND INSPECTIONS a. INSPECT PANELBOARDS AND ASSOCIATED COMPONENTS AFTER INSTALLATION AND PRIOR TO STARTUP VERIFYING INSTALLATION IS IN ACCORDANCE WITH SPECIFICATIONS AND MANUFACTURER'S RECOMMENDATIONS. b. PERFORM EACH ELECTRICAL TEST AND VISUAL AND MECHANICAL INSPECTION STATED IN NETA ACCEPTANCE TESTING SPECIFICATION. CERTIFY COMPLIANCE WITH TEST PARAMETERS. c. PREPARE AND SUBMIT TEST AND INSPECTION REPORTS. G. LIGHTING CONTACTOR PANELS 1. MOUNT ENCLOSURE WITH TOP 72 INCHES ABOVE FINISHED FLOOR. 2. INSTALL IDENTIFICATION PLATE. 3. INSPECT AND TEST LIGHTING CONTACTOR PANELS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO INSPECT, TEST, AND ADJUST EQUIPMENT INSTALLATION INCLUDING CONNECTIONS, AND TO ASSIST IN FIELD TESTING. REPORT RESULTS OF TESTS AND INSPECTIONS IN WRITIN 4. ENGAGE A FACTORY-AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN THE LIGHTING CONTROL SYSTEM.ARCHD24x36Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. Drawing Number Date Issued Project Number Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:08 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON E002 SPECIFICATIONS SUN COMMUNITIES 10/21/2022 016477.00 Date Description 12/21/22 REVISION 1 VAULTVAULTVAULT VAULTVAULT TT TT T TT TTVAULT VAULT VAULT T T TVAULT TTTTT T TT TSC-3PT T T TT T T TT STORM 10.02' 3.98'PORTNERDRIVESTREET J STREETKSTREETI RICK DRIVE STREET H STREETGRICK DRIVE STREET E STREET F CROWN RIDGE LANE CROWN RIDGE LANE STREETLSTREETLSTREET DSTREETCSTREETCSTREETBSTREET A STREET A DEBRADRIVEPITNER DRIVE RICK DRIVE DEBRADRIVEKEVINDRIVESTREET I STREETC1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 444546 47 48495051 53 54 55 56 60 61 62 64 65 66 52 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 9596979899100101102103 104105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196197 198 199 200 201 57 58 59 63 W S W S W S W S W S WS WSWSWS W S W S W SW SW SW SW SW S W SW SW S W SW SW SW SW SW S W S W S W S W SW SW S W S W S W S WS W SW SW SW S W SW S W SWSWS W SW SW SW SW SWSW SW SW SWSWSWSWS W S W S W S WS W SWS W SWS W SWS W SW SWS W SWSWS W SW SWS W SW S W S W SW S W SW SW SW SW SW SW SW SW S W S W S W S W S W S W SW SW SW SW SW SW SW SW SW SW SW S W SWSWSWSWS WS W SWS WS WS W SW SW SW SWS W SW SW SW SW SW SW SW S W S W SW SWS WSWS WS WS WS W SW SW S W SW SW SW SW SW SW S WS W S W S W S W S W S W S W S W SW SW SW SW SWSW SW SW SW SW S W S W S W SW SW SW SW SWS W SW SW SW SW SW S W S W S W S W S W S WSWSWS W S W S W S W S W S W S W S W S W S W SARCHD24x36 Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. A B C Drawing Number Date Issued Project Number Key Plan Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:14 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON ES200 OVERALL SITE LIGHTING PLAN (REFERENCE) SUN COMMUNITIES 10/21/2022 016477.00 SCALE :1" = 120'-0"1 OVERALL SITE LIGHTING PLAN (REFERENCE) Date Description 12/21/22 REVISION 1 VAULTVAULT T TTT T TT T STREETBSTREET A STREET A DEBRADRIVEPITNER DRIVE RICK DRIVE DEBRADRIVEKEVINDRIVE1 2 3 4 9596979899100101102103 104105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 137 138 139 140 141 142 143 144 145 W SW SW SW S WS WSWSWSWS W SW SW SW SW SW SWSWS W SW SWS W S W S W SW SW SW SW SWSW SW SW SW S W SWSWSWS W S W S W S W S W S W S W S W S W S W S SEESHEETES202SEESHEETES202B B B B F E E C C E C C C E C C C UNDERGROUND ELECTRIC GENERAL NOTES: A. CIRCUITRY ROUTING IS DIAGRAMMATIC AND THE CONTRACTOR SHALL FIELD CORDINATE ACTUAL ROUTING WITH SITE CONSTRAINTS AND OTHER UTILITIES.ARCHD24x36Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. A B C Drawing Number Date Issued Project Number Key Plan Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:17 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON ES201 SITE LIGHTING PLAN AREA A SUN COMMUNITIES 10/21/2022 016477.00 SCALE :1" = 50'-0"1 SITE LIGHTING PLAN AREA A Date Description 12/21/22 REVISION 1 VAULTVAULT T TTTVAULT VAULT VAULT T T TVAULT TTT TT T TSTORM RICK DRIVE STREET H STREETGRICK DRIVE STREET E STREET F STREETLSTREETLSTREET DSTREETCSTREETCSTREET A STREETC10 11 12 13 14 15 16 17 18 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 92 93 94 959697 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 WS WSWS W S W SW SW S W SW SW SW SW SW S W S W S W S W SSW SW S W SW S W SWSWS W SW SW SW SW SW SW SW SW SW S W S WS W SWS W SWS W SWS W SW SWS W SW SW SW SW S W S W SW S W SW SW SW SW SW SW SW SW SWSW W S W SW SWS WSWS WS WS WS W SW SW SWS W S W S W S W S W S W S W S W SW SW SWS W SW SW SWSW SSEESHEETES201SEESHEETES201SEESHEETES203SEESHEETES203LP1 LP1- 1,3 B B B B B B B B B B B LP1- 2,4 LP1- 6,8 P1 3#6 1#6 GND 1"C 3#6 1#6 GND 1"C 3#6 1#6 GND 1"C 3#6 1#6 GND 1"C C E E CD D D D E C EE C DD C D D C F C E E D D C C D D C C C C C LP1- 5,7 UNDERGROUND ELECTRIC GENERAL NOTES: A. CIRCUITRY ROUTING IS DIAGRAMMATIC AND THE CONTRACTOR SHALL FIELD CORDINATE ACTUAL ROUTING WITH SITE CONSTRAINTS AND OTHER UTILITIES.ARCHD24x36Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. A B C Drawing Number Date Issued Project Number Key Plan Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:21 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON ES202 SITE LIGHTING PLAN AREA B SUN COMMUNITIES 10/21/2022 016477.00 #KEYNOTES SCALE :1" = 50'-0"1 SITE LIGHTING PLAN AREA B P1 PROVIDE LIGHTING\CONTROL PANEL WITH METER ON UNISTRUT. Date Description 12/21/22 REVISION 1 VAULTVAULT TT T TT TT T 10.02' 3.98'PORTNERDRIVESTREET J STREETKSTREETI CROWN RIDGE LANE CROWN RIDGE LANE S TR E ET I 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 444546 47 48495051 53 54 55 56 60 61 62 64 65 66 52 67 192 193 194 195 196197 198 199 200 201 57 58 59 63 W S W S W S W S W S W S W S W SW SW S W SW SW SW SW SW S W SWSWSWSWS WSW SWS WS WS W SW SW SW SWS W SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW SW S W S W S W SW SW SW S W S W S W S W S W S SEESHEETES202SEESHEETES202B B B B D D C C C C C C CC C C C C C C C GENERAL NOTES: A. CIRCUITRY ROUTING IS DIAGRAMMATIC AND THE CONTRACTOR SHALL FIELD CORDINATE ACTUAL ROUTING WITH SITE CONSTRAINTS AND OTHER UTILITIES.ARCHD24x36Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. A B C Drawing Number Date Issued Project Number Key Plan Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:24 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON ES203 SITE LIGHTING PLAN AREA C SUN COMMUNITIES 10/21/2022 016477.00 SCALE :1" = 50'-0"1 SITE LIGHTING PLAN AREA C Date Description 12/21/22 REVISION 1 PANEL LP1 125A 240/120V 1Ø,3W MCB UTILITY XFMR (BY OTHERS) INCOMING UTILITY MCTS KWH METERING BY UTILITY LIGHTING CONTROL PANEL LPC1 CIVIL/ SITE CONTRACTOR TO PROVIDE PAD AND COORDINATE PAD WITH UTILITY3#1/0 1#6 GND 2"C TO NEXT UTILITY TRANSFORMER (BY OTHERS) VERIFY TRANSFORMER SECONDARY IS 240V/120V SINGLE PHASE 3-WIRE SITE, WITH CONTRACTOR PRIOR TO CONNECTION. 78" MAX COORDINATE CONDUIT RUNS WITH SITE CONDITIONS. METER POST BASE BOLTED TO PAD (TYP.) LIGHTING CONTROL PANEL NEMA 3R WIREWAY WITH PIANO HINGE PANEL LP1 125A 240/120V 1Ø,3W MCBARCHD24x36 Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. Drawing Number Date Issued Project Number Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:08 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON E601 ELECTRICAL ONE-LINE AND DETAILS SUN COMMUNITIES 10/21/2022 016477.00 NTSSCALE :1 LP1 ONE-LINE DIAGRAM SCALE :N.T.S.2 UNISTRUT MOUNTING DETAIL Date Description 12/21/22 REVISION 1 CIRCUIT VOLTAGE : 240 % ALLOWABLE VD: 3 MAX ALLOWABLE DROP: 7.2 TOTAL:1.08 0.45% C 24 0.10 43 STRANDED/CU/UNCOAT...#6 0.491 0.00 0.00% C 24 0.20 46 STRANDED/CU/UNCOAT...#6 0.491 0.01 0.00% C 24 0.30 321 STRANDED/CU/UNCOAT...#6 0.491 0.09 0.04% B 104 0.73 163 STRANDED/CU/UNCOAT...#6 0.491 0.12 0.05% B 104 1.17 290 STRANDED/CU/UNCOAT...#6 0.491 0.33 0.14% B 104 1.60 256 STRANDED/CU/UNCOAT...#6 0.491 0.40 0.17% LCP1- 2,4 B 104 2.03 59 STRANDED/CU/UNCOAT...#6 0.491 0.12 0.05% CIRCUIT LUMINAIRE ID LUMINAIRE VA CIRCUIT AMPACITY RUN LENGTH WIRE SIZE RESISTANCE/KFT VOLTAGE DROP % VD CIRCUIT VOLTAGE : 240 % ALLOWABLE VD: 3 MAX ALLOWABLE DROP: 7.2 TOTAL:5.81 2.42% B 104 0.43 381 STRANDED/CU/UNCOAT...#6 0.491 0.16 0.07% C 24 0.53 46 STRANDED/CU/UNCOAT...#6 0.491 0.02 0.01% B 104 0.97 66 STRANDED/CU/UNCOAT...#6 0.491 0.06 0.03% C 24 1.07 52 STRANDED/CU/UNCOAT...#6 0.491 0.05 0.02% C 24 1.17 48 STRANDED/CU/UNCOAT...#6 0.491 0.05 0.02% C 24 1.27 77 STRANDED/CU/UNCOAT...#6 0.491 0.10 0.04% C 24 1.37 108 STRANDED/CU/UNCOAT...#6 0.491 0.14 0.06% B 104 1.80 169 STRANDED/CU/UNCOAT...#6 0.491 0.30 0.12% C 24 1.90 91 STRANDED/CU/UNCOAT...#6 0.491 0.17 0.07% C 24 2.00 87 STRANDED/CU/UNCOAT...#6 0.491 0.17 0.07% C 24 2.10 41 STRANDED/CU/UNCOAT...#6 0.491 0.08 0.04% C 24 2.20 124 STRANDED/CU/UNCOAT...#6 0.491 0.27 0.11% C 24 2.30 87 STRANDED/CU/UNCOAT...#6 0.491 0.20 0.08% C 24 2.40 99 STRANDED/CU/UNCOAT...#6 0.491 0.23 0.10% C 24 2.50 88 STRANDED/CU/UNCOAT...#6 0.491 0.22 0.09% C 24 2.60 75 STRANDED/CU/UNCOAT...#6 0.491 0.19 0.08% C 24 2.70 75 STRANDED/CU/UNCOAT...#6 0.491 0.20 0.08% C 24 2.80 221 STRANDED/CU/UNCOAT...#6 0.491 0.61 0.25% B 104 3.23 142 STRANDED/CU/UNCOAT...#6 0.491 0.45 0.19% D 50.4 3.44 33 STRANDED/CU/UNCOAT...#6 0.491 0.11 0.05% D 50.4 3.65 47 STRANDED/CU/UNCOAT...#6 0.491 0.17 0.07% C 24 3.75 41 STRANDED/CU/UNCOAT...#6 0.491 0.15 0.06% C 24 3.85 67 STRANDED/CU/UNCOAT...#6 0.491 0.25 0.11% LCP1- 1,3 B 104 4.29 343 STRANDED/CU/UNCOAT...#6 0.491 1.44 0.60% CIRCUIT LUMINAIRE ID LUMINAIRE VA CIRCUIT AMPACITY RUN LENGTH WIRE TYPE WIRE SIZE RESISTANCE/KFT VOLTAGE DROP % VD CIRCUIT VOLTAGE : 240 % ALLOWABLE VD: 3 MAX ALLOWABLE DROP: 7.2 TOTAL:4.83 2.01% B 104 0.43 97 STRANDED/CU/UNCOAT...#6 0.491 0.04 0.02% F 6.6 0.46 27 STRANDED/CU/UNCOAT...#6 0.491 0.01 0.01% E 26.4 0.57 11 STRANDED/CU/UNCOAT...#6 0.491 0.01 0.00% E 26.4 0.68 16 STRANDED/CU/UNCOAT...#6 0.491 0.01 0.00% C 24 0.78 31 STRANDED/CU/UNCOAT...#6 0.491 0.02 0.01% C 24 0.88 317 STRANDED/CU/UNCOAT...#6 0.491 0.27 0.11% E 26.4 0.99 10 STRANDED/CU/UNCOAT...#6 0.491 0.01 0.00% E 26.4 1.10 11 STRANDED/CU/UNCOAT...#6 0.491 0.01 0.00% C 24 1.20 60 STRANDED/CU/UNCOAT...#6 0.491 0.07 0.03% C 24 1.30 69 STRANDED/CU/UNCOAT...#6 0.491 0.09 0.04% C 24 1.40 390 STRANDED/CU/UNCOAT...#6 0.491 0.54 0.22% B 104 1.83 290 STRANDED/CU/UNCOAT...#6 0.491 0.52 0.22% B 104 2.27 145 STRANDED/CU/UNCOAT...#6 0.491 0.32 0.13% B 104 2.70 63 STRANDED/CU/UNCOAT...#6 0.491 0.17 0.07% C 24 2.80 52 STRANDED/CU/UNCOAT...#6 0.491 0.14 0.06% C 24 2.90 42 STRANDED/CU/UNCOAT...#6 0.491 0.12 0.05% C 24 3.00 114 STRANDED/CU/UNCOAT...#6 0.491 0.34 0.14% LCP1- 6,8 B 104 3.43 634 STRANDED/CU/UNCOAT...#6 0.491 2.14 0.89% CIRCUIT LUMINAIRE ID LUMINAIRE VA CIRCUIT AMPACITY RUN LENGTH WIRE SIZE RESISTANCE/KFT VOLTAGE DROP % VD CIRCUIT VOLTAGE : 240 % ALLOWABLE VD: 3 MAX ALLOWABLE DROP: 7.2 TOTAL:4.38 1.83% B 104 0.43 295 STRANDED/CU/UNCOAT...#6 0.491 0.13 0.05% B 104 0.87 271 STRANDED/CU/UNCOAT...#6 0.491 0.23 0.10% B 104 1.30 254 STRANDED/CU/UNCOAT...#6 0.491 0.32 0.14% B 104 1.73 42 STRANDED/CU/UNCOAT...#6 0.491 0.07 0.03% C 24 1.83 64 STRANDED/CU/UNCOAT...#6 0.491 0.12 0.05% C 24 1.93 20 STRANDED/CU/UNCOAT...#6 0.491 0.04 0.02% D 50.4 2.14 52 STRANDED/CU/UNCOAT...#6 0.491 0.11 0.05% D 50.4 2.35 24 STRANDED/CU/UNCOAT...#6 0.491 0.06 0.02% E 26.4 2.46 13 STRANDED/CU/UNCOAT...#6 0.491 0.03 0.01% C 24 2.56 32 STRANDED/CU/UNCOAT...#6 0.491 0.08 0.03% E 26.4 2.67 38 STRANDED/CU/UNCOAT...#6 0.491 0.10 0.04% F 6.6 2.70 39 STRANDED/CU/UNCOAT...#6 0.491 0.10 0.04% D 50.4 2.91 29 STRANDED/CU/UNCOAT...#6 0.491 0.08 0.03% C 24 3.01 27 STRANDED/CU/UNCOAT...#6 0.491 0.08 0.03% B 50.4 3.22 23 STRANDED/CU/UNCOAT...#6 0.491 0.07 0.03% D 50.4 3.43 29 STRANDED/CU/UNCOAT...#6 0.491 0.10 0.04% C 24 3.53 25 STRANDED/CU/UNCOAT...#6 0.491 0.09 0.04% D 50.4 3.74 49 STRANDED/CU/UNCOAT...#6 0.491 0.18 0.08% D 50.4 3.95 21 STRANDED/CU/UNCOAT...#6 0.491 0.08 0.03% C 24 4.05 56 STRANDED/CU/UNCOAT...#6 0.491 0.22 0.09% E 26.4 4.16 10 STRANDED/CU/UNCOAT...#6 0.491 0.04 0.02% E 26.4 4.27 30 STRANDED/CU/UNCOAT...#6 0.491 0.13 0.05% C 24 4.37 45 STRANDED/CU/UNCOAT...#6 0.491 0.19 0.08% D 50.4 4.58 22 STRANDED/CU/UNCOAT...#6 0.491 0.10 0.04% D 50.4 4.79 54 STRANDED/CU/UNCOAT...#6 0.491 0.25 0.11% D 50.4 5.00 23 STRANDED/CU/UNCOAT...#6 0.491 0.11 0.05% D 50.4 5.21 44 STRANDED/CU/UNCOAT...#6 0.491 0.23 0.09% C 24 5.31 20 STRANDED/CU/UNCOAT...#6 0.491 0.10 0.04% E 26.4 5.42 11 STRANDED/CU/UNCOAT...#6 0.491 0.06 0.02% E 26.4 5.53 41 STRANDED/CU/UNCOAT...#6 0.491 0.22 0.09% E 26.4 5.64 19 STRANDED/CU/UNCOAT...#6 0.491 0.11 0.04% LCP1- 5,7 C 24 5.74 98 STRANDED/CU/UNCOAT...#6 0.491 0.55 0.23% CIRCUIT LUMINAIRE ID LUMINAIRE VA CIRCUIT AMPACITY RUN LENGTH WIRE SIZE RESISTANCE/KFT VOLTAGE DROP % VD ARCHD24x36Project Manager Designer Reviewer Discipline Lead Copyright © Bergmann Associates, Architects, Engineers, Landscape Architects & Surveyors, D.P.C. Drawing Number Date Issued Project Number Sheet Name 2 Winners Circle Suite 102 Albany, NY 12205 www.bergmannpc.com 12/20/2022 9:47:09 PMFOOTHILLS FORT COLLINS 6750 COLLEGE AVE FORT COLLINS, CO 80525 GREGG URSPRUNG D GORTON D RUSNACK A ROBINSON E801 SCHEDULES SUN COMMUNITIES 10/21/2022 016477.00 Notes: Total Est. Demand:20 A Total Conn.:16 A Total Est. Demand:4747 VA Total Conn. Load:3798 VA Lighting 3798 VA 125.00%4747 VA Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend: Total Amps:16 A 16 A Total Load:1899 VA 1899 VA 11 SPARE 20 A 1 0 --1 --SPACE 12 9 SPARE 20 A 1 0 --1 --SPACE 10 7 718 415 8 5 LITES 20 A 2 718 415 2 20 A LITES 6 3 524 245 4 1 LITES 20 A 2 524 245 2 20 A LITES 2 CKT Circuit Description Trip Poles A B Poles Trip Circuit Description CKT Notes: Enclosure:NEMA 3R MCB Rating:100 A Mounting:SURFACE Wires:3 Mains Rating:125 A Supply From:Phases:1 Mains Type:MCB Location:Volts:120/240 A.I.C. Rating:10,000 AMPS SYMMETRICAL Branch Panel: LP1 R4 1 STREET LIGHTS LP1 6,8 520VA LED X ASTRO/PHOTOCELL 30A R3 1 STREET LIGHTS LP1 5,7 520VA LED X ASTRO/PHOTOCELL 30A R2 1 STREET LIGHTS LP1 2,4 416VA LED X ASTRO/PHOTOCELL 30A R1 1 STREET LIGHTS LP1 1,3 520VA LED X ASTRO/PHOTOCELL 30A #ZONE NAME CIR #LIGHTING CONTROL STATION DIMMER/ RELAY DESCRIPTION PANELBOARD LOAD LOAD TYPE DIMMABLE ON/OFF SWITCHING NOTES RELAY RATING R=RELAY ENCLOSURE: NEMA 3R D=DIMMER MOUNTING: SURFACE SUPPLY FROM: LP1 NEW PANEL "LCP1" Date Description 12/21/22 REVISION 1