HomeMy WebLinkAboutIMPALA REDEVELOPMENT - FDP230001 - SUBMITTAL DOCUMENTS - ROUND 1 - PHOTOMETRIC PLAN2018 INTERNATIONAL ENERGY CONSERVATION CODE1. ALL LIGHTING CONTROLS SHALL COMPLY WITH SECTION C405.2 OF THE 2018 IECC.2. AS REQUIRED BY SECTION C405 ALL LIGHTING SYSTEMS SHALL BE COMMISSIONED IN AND COMPLETED IN ACCORDANCE WITH SECTION C408. THE COMMISSIONING OF THE LIGHTING CONTROLS SHALL FOLLOW THE MANUFACTURER'S INSTRUCTIONS AND BE PERFORMED BY AN APPROVED THIRD PARTY AGENCY.3. OCCUPANCY SENSORS SHALL BE TESTED TO VERIFY THEY DETECT OCCUPANTS AND CONTROL THE LIGHTS INDICATED ON THE PLANS.4. AS REQUIRED BY SECTION C408.3.2 THE COMMISSIONING DOCUMENTS DESCRIBED IN SECTION C408 SHALL BE PROVIDED TO THE OWNER WITHIN 90 DAYS OF THE DATE OF RECEIPT OF THE CERTIFICATE OF OCCUPANCY.ELECTRICAL SYMBOL SCHEDULELSURFACE ADJUSTABLE DOWNLIGHTSURFACE DOWNLIGHTRECESSED ADJUSTABLE DOWNLIGHTRECESSED DOWNLIGHTRECESSED TROFFERSURFACE TROFFERWALL MOUNTPENDANT MOUNT LINEARPENDANT MOUNTSURFACE LINEARSURFACE STRIPCONCEALED LED STRIP / TAPEROUND BOLLARDEXIT SIGN WALL MOUNT - ARROW AND FACES AS SHOWN ON PLANSEXIT SIGN CEILING MOUNT - ARROW AND FACES AS SHOWN ON PLANSEMERGENCY BATTERY UNITTRACKFLOOD / ACCENTEXTERIOR POLE MOUNTWALL MOUNTED EXIT SIGN LOW LEVELSQUARE BOLLARDCEILING MOUNTED FAN WITH CLEARANCE LUMINAIRE SYMBOLSLIGHTING CONTROL SYMBOLSa,b - SWITCH LEG(S)BLANK - SINGLE POLE SWITCH3 - 3 WAY SWITCH4 - 4 WAY SWITCHD - DIMMERD3 - DIMMER, 3 WAYDOS - DIMMER OCCUPANCY SENSOR SWITCHOS - OCCUPANCY SENSOR SWITCHT - TIMER SWITCHaSOS# - DEVICE NUMBERa,b - SWITCH LEG(S)z# - CONTROL ZONE(S)CS - CONTROL STATIONOS - OCCUPANCY SENSORVS - VACANCY SENSORTS - TOUCH SCREENPC - PHOTOCELLWITH STEM - WALL MOUNTWITHOUT STEM - CEILING MOUNTOS1aNOTES:A. SWITCH LEG DESIGNATION USED FOR ROOM(S) WITH STANDALONE LIGHTING CONTROLS. B. CONTROL ZONE DESIGNATION USED FOR LIGHTING CONTROL ZONES AS PART OF PROGRAMMABLE LIGHTING CONTROL PANEL. ABBREVIATIONSRCP REFLECTED CEILING PLANLLFLIGHT LOSS FACTORLED LIGHT EMITTING DIODECRICOLOR RENDERING INDEXCCT CORRELATED COLOR TEMPERATURECL CONNECTED LOADDLDESIGN LOADDF DEMAND FACTOROC OVER CURRENTVDVOLTAGE DROPFSD FIRE SMOKE DAMPERPPOLENNEUTRALEMS EMERGENCY MANAGEMENT SYSTEMVFDVARIABLE FREQUENCY DRIVE(N) NEW(F) FUTURE(R) RELOCATE EXISTING(D) DEMOLISH EXISTING(E)EXISTING TO REMAINFLC FULL LOAD CURRENT (NEC)FLAFULL LOAD AMPS (NAME PLATE)MOCP MAXIMUM OVER CURRENT PROTECTIONMCAWWATTVA VOLT AMPERESVVOLTTEL TELEPHONETCTERMINAL CABINETTB, TTB TERMINAL BACKBOARDSWGRSWITCH GEARSWBD SWITCHBOARDSPST SINGLE POLE, SINGLE THROWSPDT SINGLE POLE, DOUBLE THROWRSC RIGID STEEL CONDUITPWR POWERPVCPOLYVINYL CHLORIDE CONDUITPNLPANEL∅, PHPHASEPBPULL BOXOFCIOWNER FURNISHEDCONTRACTOR INSTALLEDNTS NOT TO SCALENO NORMALLY OPENNLNIGHT LIGHTNEMANATIONAL ELECTRICALMANUFACTURER'S ASSOCIATIONNC NORMALLY CLOSEDMLO MAIN LUGS ONLYMCB MAIN CIRCUIT BREAKERLRC LIGHTING RELAY CABINETHPFHIGH POWER FACTORHP HORSEPOWERHOA HAND - OFF - AUTOIG ISOLATED GROUND.GENERATORGENG, GND GROUNDGFCIGROUND FAULTCIRCUIT INTERRUPTINGFVR FULL-VOLTAGE, REVERSINGFVNR FULL-VOLTAGE, NON-REVERSINGFA FIRE ALARMELECTRO METALLIC TUBINGEMTE, EM EMERGENCYELEVELEVATORELEC ELECTRICALEC EMPTY CONDUITDIST DISTRIBUTIONDPST DOUBLE POLE SINGLE THROWDPDT DOUBLE POLE, DOUBLE THROWDCDIRECT CURRENTCLG CEILINGCKT CIRCUITCFOICONTRACTOR FURNISHED OWNER INSTALLEDCCONDUITAV AUDIO VISUALAWG AMERICAN WIRE GAUGEAT TRIP RATING IN AMPERESAS SWITCH RATING IN AMPERESAF FRAME RATING IN AMPERESATS AUTOMATIC TRANSFER SWITCHAFG ABOVE FINISHED GRADEAFF ABOVE FINISHED FLOORAIC AMPERE INTERRUPTING CAPACITYACT ABOVE COUNTER TOPAC ALTERNATING CURRENTA, AMP AMPEREWWIREXFMRTRANSFORMERVMINIMUN CIRCUIT AMPSELECTRICAL GENERAL NOTESA. WHERE GROUNDED CONDUCTORS OF DIFFERENT SYSTEMS ARE INSTALLED IN THE SAME RACEWAY, CABLE, BOX, AUXILIARY GUTTER, OR OTHER TYPE OF ENCLOSURE, EACH GROUNDED CONDUCTOR SHALL BE IDENTIFIED BY SYSTEM PER NEC ARTICLE 200.6 (D). MEANS OF IDENTIFICATION SHALL BE PERMANENTLY POSTED AT EACH BRANCH CIRCUIT PANELBOARD.B. PER NEC ART 210.5 (C), UNGROUNDED CONDUCTORS OF MORE THAN ONE NOMINAL VOLTAGE SYSTEM SHALL BE IDENTIFIED BY SYSTEM. PROVIDE MEANS OF IDENTIFICATION AS REQUIRED PER THIS ARTICLE.C. PER NEC ART 215.12, FEEDER IDENTIFICATION IS REQUIRED WHEN MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXISTS. PROVIDE MEANS OF IDENTIFICATION AS REQUIRED PER THIS ARTICLE.D. VERIFY FINAL PLACEMENT AND CONNECTION REQUIREMENTS PRIOR TO ROUGHING IN EQUIPMENT UTILITIES.E. FINAL ACCEPTANCE OF WORK IN PLACE SHALL BE SUBJECT TO APPROVAL BY OWNER'S REPRESENTATIVE. INSTALLATION APPROVAL SHALL BE BASED ON APPROVED SUBMITTAL, SHOP DRAWINGS AND LOCAL INSPECTIONS.F. SUBMIT RED-LINE RECORD DRAWINGS WITHIN TWO (2) WORK WEEKS OF DATE OF NOTIFICATION OF FINAL APPROVAL.G. ALL WORK SHOWN ON DRAWINGS IS IN PART SCHEMATIC, INTENDED TO CONVEY SCOPE OF WORK AND GENERAL LAYOUT. VERIFY ALL EXISTING CONDITIONS AND MAKE ADJUSTMENTS AS REQUIRED. ELECTRICAL DRAWINGS ARE LARGELY DIAGRAMMATIC AND, THEREFORE, REPRESENT INSTALLATION INTENT AND GUIDELINES; IT IS THE CONTRACTOR'S RESPONSIBILITY TO COVER ALL CONDITIONS ON THEIR PREPARED SHOP DRAWINGS.H. PROVIDE UP-TO-DATE, ACCURATE, AND LEGIBLE CIRCUIT DIRECTORY WHICH APPLIES TO PANELBOARDS AND SWITCHBOARDS AS REQUIRED BY NEC ART. 408.4 DIRECTORY SHALL BE LOCATED ON THE FACE OR ON THE DOOR OF EACH PANELBOARD OR AT EACH SWITCH ON A SWITCHBOARD. WITHIN EACH PANELBOARD PRIOR TO FINAL ACCEPTANCE OF WORK IN PLACE.I. LABEL ALL WIRING DEVICES WITH SOURCE PANELBOARD AND CIRCUIT NUMBER ON COVER PLATE. SEE SPECIFICATIONS.J. LABEL ALL NEW PANELBOARDS, SWITCHBOARDS AND MOTOR CONTROL CENTERS WITH ENGRAVED LAMINATED-PLASTIC NAMEPLATES MOUNTED WITH CORROSION-RESISTANT SCREWS. SEE SPECIFICATIONS.K. ALL INTERIOR OUTLET, JUNCTION AND PULL BOXES SHALL BE METALLIC, SIZED PER CODE FOR THE NUMBER OF CONDUCTORS THEREIN.L. ALL ELECTRICAL RACEWAYS SHALL BE CONCEALED IN THE WALLS AND ABOVE SUSPENDED CEILING UNLESS OTHERWISE NOTED.M. ALL CONDUCTORS SHALL BE #12 AWG MINIMUM TYPE THHN/THWN UNLESS OTHERWISE NOTED.N. ALL CEILING MOUNTED ELECTRICAL DEVICES SHALL BE SUPPORTED FROM THE CEILING GRID, NOT FROM CEILING TILE. LIGHTING SHALL BE SUPPORTED FROM STRUCTURE ABOVE.O. ELECTRICAL PLANS ARE MOSTLY DIAGRAMMATIC. CONTRACTOR SHALL PROVIDE CONNECTIONS BETWEEN FIXTURES AND LIGHTING CONTROL DEVICES SUCH AS OCCUPANCY SENSORS, LIGHT SWITCHES, AND LIGHTING CONTROL PANEL TO PROVIDE AN OPERABLE LIGHTING SYSTEM.P. IN THE EVENT OF ANY INCONSISTENCY BETWEEN ITEMS INDICATED ON THE PLANS AND/OR THE SPECIFICATIONS, THE ONE WHICH PROVIDED THE MOST COMPLETE WORK OR HIGHER STANDARD SHALL PREVAIL.Q. SUPPLY AND INSTALL ALL REQUIRED SUPPORTS AND BRACING OF EQUIPMENT AND CONDUITS FOR PROPER EQUIPMENT INSTALLATIONS AND CODE COMPLIANCE.R. ALL EXPOSED CONDUITS SHALL BE INSTALLED AT RIGHT ANGLE TO ROOM OR STRUCTURE. EXPOSED CONDUITS SHALL BE SUPPORTED FROM BUILDING STRUCTURE USING APPROVED PIPE HANGERS.S. ALL CONDUITS SHALL BE SIZED AS PER NEC UNLESS LARGER SIZES ARE NOTED ON THE DRAWINGS.T. ALL CUTTING, PATCHING AND PAINTING REQUIRED FOR THE CONCEALED INSTALLATION OF CONDUITS SHALL BE PROVIDED BY THE CONTRACTOR. DO NOT CUT OR DRILL STRUCTURAL MEMBERS WITHOUT WRITTEN APPROVAL FROM STRUCTURAL ENGINEER. ALL CUTTING AND PATCHING SHALL BE NEAT, AND PATCHING SHALL MATCH ADJACENT SURFACE AS TO TEXTURE AND FINISH.U. ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS OR CEILINGS SHALL BE SEALED IN ACCORDANCE WITH A UL APPROVED SYSTEM THAT MAINTAINS THE INTEGRITY OF THE EXISTING FIRE RATING. PROVIDE AN ENCLOSURE OF EQUAL FIRE RESISTANT RATING AROUND ALL FIXTURES AND EQUIPMENT INSTALLED IN OR PENETRATING FIRE RATED SEPARATIONS.V. ALL DATA CABLING TO BE PROVIDED BY THE OWNERS'S IT VENDOR. COORDINATE ROUGH-IN WORK WITH OWNER'S IT VENDOR.DRAWING INDEXL001 COVER SHEETL100 SITE LIGHTING PLAN - 306 IMPALAL110 SITE LIGHTING CALCULATIONS - 306 IMPALAL120 SITE LIGHTING PLAN - 400 MULBERRYL130 SITE LIGHTING CALCULATIONS - 400 MULBERRYL200 SITE LIGHTING CUTSHEETS1999 BROADWAYSUITE 2205DENVER, CO80202 | USA(T) 720 644 5044www.mazzetti.comProject Number:3575 Ringsby Ct, Ste 300ASTUDIO ARCHITECTUREDenver, CO 80216theSTUDIOarchitecture.com866.529.9130COPYRIGHTPLOT DATE:CSTUDIO Project No:Sheet Issue & Revision LogIt is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client shall be responsible for any defects in construction if these procedures are not followed.NoDateDescriptionFOR REFERENCE ONLYDRAWN BY:REVIEWED BY:004-6006111/10/2023 6:42:41 PML001COVER SHEET21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJBBSIMPALAREDEVELOPMENTNOTES:1. ALL LIGHTING FIXTURES SHALL BE UL LISTED.2. ALL EXTERIOR AND SITE/LANDSCAPE LIGHTING MUST ADHERE TO ALL LOCAL LIGHTING ORDINANCES AND REQUIREMENTS. PROVIDE SHIELDING, GLARE CONTROL, HARDWARE OPTIONS AND ACCESSORIES AS NECESSARY TOCOMPLY.3. CONFIRM ALL FIXTURE FINISHES, TRIMS, ACCESSORIES, ETC. FINAL APPROVAL OF ALL LIGHT FIXTURES TO BE BY THE ARCHITECT AND OWNER DURING SUBMITTAL PHASE AND PRIOR TO ANY ORDERING, PURCHASE ORINSTALLATION OF LIGHT FIXTURES.4. FIXTURES INSTALLED WITHIN RATED ASSEMBLIES SHALL BE PROVIDED AND/OR INSTALLED ACCORDINGLY TO MATCH THE RATING OF THE ASSEMBLY.5. ALL TYPES E1, E2, AND E3 ARE LOCATED ALONG PRIVATE STREET, PARKING LOTS AND DRIVES, AND ARE IDEALLY LOCATED.6. BOTH SITES ARE CLASSIFIED AS LC1.7. TYPE E3 BOLLARD IS FULL CUTOFF WITH U1 RATING FROM LIGHT REFLECTED OFF OF STEM.EXCITY OF FORTCOLLINSSTANDARDCITY OF FORT COLLINSSTANDARDEXTERIOR POLE MOUNTED LED AREA LIGHT WITHINTEGRAL DRIVER. UL WET LOCATION LISTED. PLEASENOTE LUMEN PACKAGE AND TYPE T3 DISTRIBUTION TOBE CONFIRMED.8250 73W 3000K 80 NON-DIM18' EXISTING PEDPOLE25' EXISTING COBRAHEADTYPE 3 -E7 ILP SWP-1L-U-30-FINISH-10YRWALL MOUNTED SCONCE WITH DIMMING DRIVER. ULWET LOCATION LISTED.1000 10W 3000K 80 NON-DIM 6' AFG SYMMETRICAL B1-U0-G0E6 VISION-3 FL1A-FINISH-RND-C4-K1-118-H1SURFACE MOUNTED MONOPOINT WITH DIMMINGDRIVER. UL WET LOCATION LISTED.400 6W 3000K 80 ELV 10' AFG SYMMETRICAL N/AE5 ALUZA5-ZOZO-STN-24"-27K-GSF-DM-WET-LENGTHEXTERIOR CATENARY LED GLOBE LIGHTING SPACED 24INCHES APART ON CENTER. UL WET LOCATION LISTED.PROVIDE WITH MOUNTING CABLE PLATES AND ALLHARDWARE FOR COMPLETE AND FUNCTIONAL SYSTEM.PROVIDE WITH STRAIGHT RUN.48 1W 2700K 80 ELV 12' CATENARY LIGHT SYMMETRICAL N/AE4GENERATIONLIGHTING863740112EXTERIOR BUILDING MOUNTED LED SCONCE WITHINTEGRAL DIMMING DRIVER. UL WET LOCATION LISTED.400 5W 3000K 80 ELVBOTTOM OF FIXTURE AT 6'-6" AFFFLOOD FULLCUT OFFN/AE3 SIGNIFYPBL-36-14L-100-WWG2-5-VOLT-FINISHEXTERIOR GROUND MOUNTED LED BOLLARD WITHINTEGRAL DIMMING DRIVER. UL WET LOCATION LISTED.343 5W 3000K 80 STEP 42 INCH BOLLARDTYPE 5CUT OFFB0-U1-G0E2A ILPSAS-2L-U-30-T4-UNV-FINISH-10YR+ FSP-311/L20EXTERIOR POLE MOUNTED LED PEDESTRIAN LIGHTWITH INTEGRAL DIMMING DRIVER. UL WET LOCATIONLISTED.2000 20W 3000K 80 STEP 20' ROUND POLETYPE 4 FULLCUT OFFB1-U0-G1E2 ILPSAS-2L-U-30-T2-UNV-FINISH-10YR+ FSP-311/L20EXTERIOR POLE MOUNTED LED PEDESTRIAN LIGHTWITH INTEGRAL DIMMING DRIVER. UL WET LOCATIONLISTED.2000 20W 3000K 80 STEP 15' ROUND POLETYPE 2 FULLCUT OFFB1-U0-G1E1 ILPSAS-2L-U-30-T3-UNV-FINISH-10YR+ FSP-311/L20EXTERIOR POLE MOUNTED LED AREA LIGHT WITHINTEGRAL DIMMING DRIVER. UL WET LOCATION LISTED.TO BE PROVIDED WITH A DERATED DRIVER TO LIMITLUMEN OUTPUT PER SCHEDULE. UL WET LOCATION.2000 20W 3000K 80 STEP 20' ROUND POLETYPE 3 FULLCUT OFFB1-U0-G1TYPE MANUFACTURER MODELDESCRIPTION LUMENS WATTS CCT CRIDIMMINGINTERFACEMOUNTING HEIGHTDISTRIBUTIONTYPEBUG RATINGSITE LUMINAIRE SCHEDULESITE LUMEN LIMIT 118,915 PROPOSED LUMENS 101,503E7 2 1000 2,000E6 9 400 3,600E5 130 48 6,240SPORT COURTS 1,500 1.25 1,736 E4 44 400 17,600DINING 1,389 1.25 8,263 E3 41 343 14,063PORCH 6,610 1.25 8,263 E2A 4 2,000 8,000SIDEWALK 19,706 1.25 24,633 E2 17 2,000 34,000PARKING & DRIVES 60,817 1.25 76,021 E1 8 2,000 16,000AREA TYPE SF BASE ALLOWANCE TOTAL TYPES QTY LUMENS TOTALEXTERIOR LIGHTING ALLOWANCE (HARDSCAPE AREA METHOD)1 04/13/22 PDP3 06/08/22 PDP RD 24 07/27/22 PDP RD 35 10/19/22 PDP RD 46 01/11/23 FDP RD 1FDP SUBMITTALP
BBBBBBBBBBBBBB
B
B
B
B
B
B
B
BBBBB
B
B
B
BBB BB
B
B
B
BBB
B
BBBBB
B
BB
B
B
BBBBB
B
B
BBBBBBBB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBBBBBBB
B
B
B
B
B
B
B BBBB
B
B
BBBB
B
B
B
B
B
B
BBBBBBBBBBBBB6'6'6'BBB
B BBBBBBBBBBB
B
IMPALA CIRCLEIMPALA CIRCLEIMPALA CIRCLEIMPALA DRIVEWVWVV A UL T
E L EC
V A UL T
E L EC
V A UL T
E L EC
SSV A UL T
C A BL E
WVSSFOCCCCCCCCCCCCCCCCCCCCCPROPOSED BUILDING B TRANSFORMER LOCATIONPROPOSED BUILDING C TRANSFORMER LOCATIONPROPOSED BUILDING A TRANSFORMER LOCATIONPROPOSED BUILDING A UTILITY METER AND MAIN SWITCHGEAR LOCATIONPROPOSED BUILDING B UTILITY METER AND MAIN SWITCHGEAR LOCATIONPROPOSED BUILDING B UTILITY METER AND MAIN SWITCHGEAR LOCATIONE1,z11E1,z11E1,z11E1,z11E1,z11E1,z11E1,z11E1,z11E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E2,z12E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E2,z12E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13E3,z13 E3,z13E3,z13E3,z13E3,z13E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14EXEXE4,z14EXE2A,z18E2A,z18E2A,z18E2A,z18L2L2E3,z13E3,z13E2,z12E3,z13E3,z13E3,z13L1E7,z17E7,z17E6,z6E6,z6E6,z6E6,z6E6,z6EXL1L3L3L3L3E5,z15E5,z15E5,z15E5,z15E5,z15E5,z15PROPERTY BOUNDARYPROPERTY BOUNDARYE3,z13E3,z13E4,z14E4,z14E4,z141999 BROADWAYSUITE 2205DENVER, CO80202 | USA(T) 720 644 5044www.mazzetti.comProject Number:3575 Ringsby Ct, Ste 300ASTUDIO ARCHITECTUREDenver, CO 80216theSTUDIOarchitecture.com866.529.9130COPYRIGHTPLOT DATE:CSTUDIO Project No:Sheet Issue & Revision LogIt is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client shall be responsible for any defects in construction if these procedures are not followed.NoDate DescriptionFOR REFERENCE ONLYDRAWN BY: REVIEWED BY:004-6006111/10/2023 6:42:44 PML100SITE LIGHTING PLAN -306 IMPALA21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJBBSIMPALAREDEVELOPMENTKEYNOTESL1 EXISTING STREET LIGHT OWNED AND OPERATED BY THE CITY OF FORTCOLLINS. LIGHT WAS INCLUDED IN PERMIT CALCULATIONS AND ASSUMEDTO REMAIN IN OPERATION BY THE CITY OF FORT COLLINS TO MAINTAINPROPER LIGHT LEVELS ALONG PUBLIC RIGHT OF WAY.L2 EXISTING HPS POLE LUMINAIRES AS SHOWN BEING REPLACED BY THE CITYTO THEIR STANDARD LED FIXTURES PER DISCUSSIONS WITH THE CITY OFFORT COLLINS.L3 PROVIDE LOCAL CONTROL FOR ON/OFF AND DIMMING CONTROL. ROUTECIRCUIT THROUGH PLCP FOR ASTRONOMICAL TIME CLOCK CONTROL.BLDG AKEY PLAN -306 IMPALA1" = 20'-0"L1001LIGHTING SITE PLAN - 3061 04/13/22 PDP3 06/08/22 PDP RD 24 07/27/22 PDP RD 35 10/19/22 PDP RD 46 01/11/23 FDP RD 1FDP SUBMITTALP
BBBBBBBBBBBBBB
B
B
B
B
B
B
B
BBBBB
B
B
B
BBB BB
B
B
B
BBB
B
BBBBB
B
BB
B
B
BBBBB
B
B
BBBBBBBB
B
B
B
B
B
B
B
B
B
B
B
B
B
B
B
BBBBBBBBB
B
B
B
B
B
B
B BBBB
B
B
BBBB
B
B
B
B
B
B
BBBBBBBBBBBBB6'6'6'BBB
B BBBBBBBBBBB
B
IMPALA CIRCLEIMPALA CIRCLEIMPALA CIRCLEIMPALA DRIVEWVWVV A UL T
E L EC
V A UL T
E L EC
V A UL T
E L EC
SSV A UL T
C A BL E
WVSSFOCCCCCCCCCCCCCCCCCCCCC0.1 0.4 1.90.1 0.4 2.10.1 0.4 1.80.1 0.5 1.50.1 0.50.1 0.40.1 0.30.1 0.20.10.10.10.1 0.1 0.10.1 0.1 0.10.1 0.1 0.10.2 0.2 0.20.3 0.3 0.40.3 0.3 0.4 0.50.3 0.4 0.6 0.70.4 0.5 0.6 0.80.5 0.6 0.6 0.70.7 0.7 0.6 0.60.9 0.8 0.7 0.51.2 1.0 0.7 0.41.6 1.2 0.7 0.41.9 1.3 0.7 0.32.0 1.3 0.7 0.31.71.2 0.7 0.31.3 1.0 0.6 0.30.9 0.8 0.6 0.30.7 0.6 0.5 0.30.5 0.5 0.4 0.30.3 0.4 0.4 0.30.3 0.3 0.4 0.50.2 0.3 0.5 0.60.2 0.3 0.6 0.70.3 0.7 0.90.2 0.7 1.30.2 0.8 2.00.1 0.8 2.50.1 0.8 2.70.00.00.00.00.00.00.00.00.00.0 0.00.0 0.00.0 0.00.0 0.0 0.00.0 0.0 0.00.0 0.0 0.00.0 0.0 0.02.4 4.8 3.1 0.5 0.2 0.1 0.10.1 0.12.34.52.9 0.4 0.2 0.1 0.10.1 0.1 0.1 0.1 0.1 0.11.9 2.91.70.3 0.1 0.1 0.10.1 0.1 0.1 0.1 0.2 0.2 0.2 0.11.4 1.7 0.9 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.10.1 0.1 0.1 0.2 0.2 0.2 0.3 0.2 0.3 0.4 0.3 0.20.9 1.0 0.6 0.2 0.2 0.3 0.4 0.5 0.5 0.4 0.4 0.5 0.5 0.5 0.4 0.4 0.40.3 0.4 0.5 0.5 0.4 0.5 0.5 0.5 0.5 0.6 0.4 0.2 0.10.6 0.7 0.4 0.3 0.3 0.4 0.6 0.9 0.9 0.7 0.7 0.8 1.0 0.9 0.6 0.6 0.60.5 0.6 0.8 0.8 0.6 0.6 0.8 0.8 0.8 0.8 0.6 0.3 0.10.5 0.4 0.3 0.3 0.4 0.6 0.7 1.01.10.9 1.0 1.01.11.0 0.8 0.7 0.7 0.7 0.8 0.9 0.9 0.8 0.9 1.01.1 1.11.2 0.9 0.4 0.1 0.10.3 0.3 0.2 0.1 0.7 0.7 0.3 0.51.70.6 0.8 1.0 1.2 1.3 1.2 0.9 0.1 0.6 2.21.10.41.51.61.11.21.4 1.4 1.10.5 0.1 0.1 0.10.2 0.1 0.10.2 10.4 0.3 0.8 3.0 3.2 1.9 1.6 1.1 1.2 1.1 0.5 0.1 0.1 0.10.1 0.10.4 0.5 0.7 1.1 1.5 1.8 1.3 1.5 1.2 0.7 0.2 0.1 0.10.1 0.10.7 1.1 1.3 1.5 1.7 2.0 1.5 1.6 1.2 0.8 0.2 0.10.1 0.1 0.31.81.4 1.7 1.72.0 2.21.4 1.51.2 0.6 0.2 0.1 0.10.11.41.34.0 1.6 1.01.4 1.51.8 2.01.71.6 1.2 0.6 0.1 0.1 0.10.1 0.20.3 0.6 0.4 0.5 1.9 4.01.7 1.5 1.4 1.10.5 0.1 0.1 0.10.1 0.1 0.1 0.2 3.4 0.5 0.1 0.5 2.5 3.7 1.2 1.0 1.8 0.4 0.6 0.1 0.10.1 0.2 0.3 0.5 0.7 4.1 1.5 1.3 1.1 0.8 0.4 0.1 0.10.1 2.4 1.0 2.5 1.1 2.5 1.1 2.6 1.1 2.8 4.2 0.5 0.6 0.6 0.6 4.3 1.44.9 0.95.43.4 3.4 1.6 1.9 1.5 1.3 1.0 0.6 0.4 0.2 0.10.1 0.2 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.5 1.0 0.8 1.2 1.2 0.9 0.7 0.40.2 0.1 0.3 2.01.74.71.31.7 1.41.0 0.5 0.4 0.2 0.10.2 0.2 0.2 0.3 0.3 10.8 9.1 0.5 0.3 0.45.10.7 1.2 1.21.51.30.9 1.9 0.9 0.5 0.4 0.3 0.2 0.10.4 2.21.13.5 2.81.71.9 2.61.12.01.70.5 0.91.11.0 0.50.91.7 1.50.6 0.5 0.5 0.4 0.2 0.10.5 0.5 0.4 0.14.2 0.3 0.7 1.0 0.9 0.31.5 1.4 0.9 0.6 0.5 0.5 0.5 0.3 0.10.8 0.8 0.71.1 0.2 0.5 0.6 0.8 0.52.0 1.3 1.0 0.7 0.5 0.5 0.6 0.5 0.10.6 0.7 2.12.7 0.3 0.3 0.5 0.6 1.00.51.10.9 0.7 0.5 0.6 0.6 0.5 0.10.8 0.8 0.85.9 1.3 0.2 0.3 0.4 0.3 0.70.51.10.8 0.7 0.5 0.6 0.6 0.3 0.10.7 0.6 0.50.7 1.9 0.2 0.2 0.3 0.3 0.91.21.10.9 0.7 0.6 0.6 0.6 0.3 0.10.4 0.4 0.71.8 1.5 0.1 0.2 0.2 0.2 1.0 1.22.2 1.3 1.2 0.8 0.6 0.6 0.6 0.3 0.10.3 0.2 0.71.9 1.5 0.1 0.1 0.1 0.1 0.9 1.60.6 1.2 1.1 0.7 0.6 0.6 0.6 0.3 0.10.2 0.2 0.20.1 1.8 0.1 0.1 0.1 0.21.42.23.2 1.0 0.9 0.7 0.5 0.6 0.6 0.5 0.10.1 0.1 0.10.11.10.1 0.1 0.6 0.10.7 1.0 0.7 0.6 0.5 0.6 0.7 0.6 0.10.1 0.1 0.64.8 2.4 0.1 0.1 0.1 0.21.50.13.2 1.0 0.8 0.6 0.5 0.6 0.6 0.4 0.10.1 0.1 0.30.8 0.9 0.1 0.1 0.1 0.1 0.6 2.20.5 1.1 1.0 0.7 0.6 0.6 0.6 0.3 0.10.1 0.1 0.12.0 2.5 0.2 0.1 0.1 0.2 1.62.6 1.1 1.0 0.7 0.6 0.6 0.6 0.4 0.10.1 0.1 0.13.0 0.9 0.2 0.2 0.2 0.2 0.6 0.51.0 0.8 0.7 0.6 0.6 0.6 0.6 0.4 0.10.1 0.1 0.98.7 2.5 0.5 0.6 0.5 0.5 1.95.42.6 0.7 0.5 0.5 0.5 0.6 0.6 0.5 0.10.1 0.10.2 0.7 0.9 0.8 0.7 0.30.1 0.5 0.5 0.5 0.5 0.6 0.7 0.6 0.10.2 0.1 0.1 0.1 0.2 0.1 1.35.50.3 0.3 0.5 0.6 0.6 0.6 0.5 0.5 0.3 0.3 0.4 0.3 6.0 1.1 0.4 0.2 0.60.6 0.6 0.6 0.7 0.7 0.5 0.20.3 0.3 0.4 0.6 0.8 1.1 1.2 1.3 1.0 1.0 1.4 1.6 1.5 1.3 1.3 1.3 1.11.2 1.3 1.4 1.5 1.3 1.3 1.3 1.2 1.1 1.0 0.9 0.8 0.7 0.4 0.10.5 0.4 0.4 0.5 0.71.11.0 0.8 0.8 0.9 1.0 4.8 2.21.11.3 1.3 1.0 0.9 1.21.41.2 1.01.11.3 1.2 1.0 1.0 0.9 0.8 0.5 0.3 0.10.6 0.4 0.3 0.4 0.5 0.7 0.7 0.7 0.7 0.7 1.0 1.6 1.2 0.8 0.9 0.9 0.80.8 0.9 1.0 0.9 0.9 0.9 1.0 1.0 1.0 0.9 0.8 0.5 0.4 0.2 0.10.7 0.4 0.2 0.3 0.4 0.5 0.5 0.5 0.5 0.5 0.7 0.6 0.6 0.6 0.6 0.6 0.60.6 0.6 0.6 0.6 0.7 0.7 0.8 0.9 0.9 0.9 0.5 0.3 0.3 0.2 0.11.1 0.5 0.2 0.2 0.3 0.4 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.60.6 0.5 0.6 0.6 0.7 0.7 0.8 0.8 0.7 0.5 0.3 0.2 0.2 0.12.0 0.7 0.2 0.3 0.3 0.4 0.5 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.50.5 0.5 0.5 0.6 0.7 0.8 0.7 0.5 0.4 0.3 0.2 0.2 0.1 0.13.51.10.3 0.2 0.2 0.2 0.3 0.5 0.4 0.3 0.3 0.3 0.3 0.3 0.5 0.5 0.3 0.3 0.30.3 0.3 0.5 0.5 0.3 0.2 0.2 0.2 0.1 0.1 0.15.2 1.6 0.4 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.10.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.14.81.50.4 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.10.1 0.1 0.1 0.1 0.1 0.10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.00.0 0.0 0.00.0 0.00.0 0.00.00.00.00.00.00.00.00.00.00.00.0 0.00.00.00.00.0 0.00.0 0.0 0.0 0.00.00.00.0 0.0 0.0 0.0 0.0Calculation SummaryLabelCalcTypeUnits Avg Max MinAvg/Min Max/MinImpala Drive - 306 ImpalaIlluminance Fc0.50 2.7 0.0N.A. N.A.Overall Site LightingIlluminance Fc 0.73 10.8 0.0 N.A. N.A.Property Line - 306 Impala Illuminance Fc 0.33 6.3 0.0 N.A. N.A.Property Line 10' OffsetIlluminance Fc0.325.40.0N.A. N.A.1999 BROADWAYSUITE 2205DENVER, CO80202 | USA(T) 720 644 5044www.mazzetti.comProject Number:3575 Ringsby Ct, Ste 300ASTUDIO ARCHITECTUREDenver, CO 80216theSTUDIOarchitecture.com866.529.9130COPYRIGHTPLOT DATE:CSTUDIO Project No:Sheet Issue & Revision LogIt is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client shall be responsible for any defects in construction if these procedures are not followed.NoDate DescriptionFOR REFERENCE ONLYDRAWN BY: REVIEWED BY:004-6006111/10/2023 6:42:45 PML110SITE LIGHTINGCALCULATIONS -306IMPALA21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJBCheckerIMPALAREDEVELOPMENT1" = 20'-0"L1101LIGHTING SITE PLAN PHOTOMETRICS - 3061 04/13/22 PDP3 06/08/22 PDP RD 24 07/27/22 PDP RD 35 10/19/22 PDP RD 46 01/11/23 FDP RD 1FDP SUBMITTALBSP
5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)9HC PARKINGC A BL ECTC CTCWVHYDV A UL T
F.O .GGGGGEEEEESCELECE4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E4,z14E3,z13E3,z13E3,z13E2,z12E2,z12E6,z6E6,z6E6,z6E6,z6E1,z11E3,z13E3,z13E3,z13E3,z13E3,z13E2,z12E3,z13E3,z13E3,z13E3,z13E3,z13PROPERTY BOUNDARY1999 BROADWAYSUITE 2205DENVER, CO80202 | USA(T) 720 644 5044www.mazzetti.comProject Number:3575 Ringsby Ct, Ste 300ASTUDIO ARCHITECTUREDenver, CO 80216theSTUDIOarchitecture.com866.529.9130COPYRIGHTPLOT DATE:CSTUDIO Project No:Sheet Issue & Revision LogIt is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client shall be responsible for any defects in construction if these procedures are not followed.NoDate DescriptionFOR REFERENCE ONLYDRAWN BY: REVIEWED BY:004-6006111/10/2023 6:42:46 PML120SITE LIGHTING PLAN -400 MULBERRY21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJBBSIMPALAREDEVELOPMENT1" = 20'-0"L1201LIGHTING SITE PLAN - 4001 04/13/22 PDP3 06/08/22 PDP RD 24 07/27/22 PDP RD 35 10/19/22 PDP RD 46 01/11/23 FDP RD 1FDP SUBMITTALP
5085 (NAVD88)5084 (NAVD88)5083 (NAVD88)9HC PARKINGC A BL ECTC CTCWVHYDV A UL T
F.O .GGGGGEEEEESCELEC0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.00.0 0.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.00.0 0.0 0.1 0.1 0.2 0.2 0.3 0.1 0.11.10.3 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.2 0.3 0.3 1.0 0.3 0.0 0.4 0.80.0 0.0 0.0 0.0 0.00.0 0.1 0.2 0.3 0.3 0.4 0.50.0 0.0 0.0 0.0 0.00.0 0.1 0.2 0.4 0.5 0.6 0.7 2.40.1 0.0 0.0 0.0 0.00.0 0.1 0.2 0.4 0.6 0.7 0.8 3.80.2 0.0 0.0 0.0 0.00.0 0.1 0.2 0.4 0.6 0.8 1.0 0.40.1 0.0 0.0 0.0 0.00.0 0.1 0.2 0.5 0.7 0.8 0.9 4.10.1 0.0 0.0 0.0 0.00.0 0.1 0.3 0.5 0.7 0.9 0.6 0.30.1 0.0 0.0 0.0 0.00.0 0.2 0.3 0.5 0.7 0.8 0.7 0.3 0.6 0.1 0.0 0.0 0.0 0.00.1 0.2 0.4 0.5 0.8 1.0 1.3 1.8 0.2 0.2 1.61.50.3 0.3 0.8 0.0 0.0 0.0 0.0 0.00.0 0.1 0.4 0.4 0.6 0.91.11.0 0.0 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.1 0.1 0.5 0.4 0.5 0.7 0.8 0.8 0.2 0.2 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.1 0.1 0.2 0.7 0.6 0.5 0.5 0.8 0.9 0.2 0.1 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.1 0.1 0.3 0.9 0.8 1.2 0.4 1.9 4.3 0.4 0.1 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.9 0.8 3.0 0.4 0.5 0.4 0.1 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.6 0.51.10.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.1 0.5 0.4 3.6 0.1 0.1 0.10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.3 0.9 0.10.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.2 3.90.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.10.2 0.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.10.0 0.2 4.8 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.10.0 0.1 1.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.20.0 0.3 2.0 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.60.7 0.6 0.5 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.5 0.50.6 0.5 0.5 0.3 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.4 0.40.4 0.4 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.30.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.10.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0Calculation SummaryLabelCalcTypeUnits Avg Max MinAvg/Min Max/MinMulberry SiteIlluminance Fc 0.14 4.8 0.0 N.A. N.A.Property Line - 10' OffsetIlluminance Fc 0.00 0.1 0.0 N.A. N.A.Property Line - 400 Impala Illuminance Fc 0.03 0.5 0.0 N.A. N.A.1999 BROADWAYSUITE 2205DENVER, CO80202 | USA(T) 720 644 5044www.mazzetti.comProject Number:3575 Ringsby Ct, Ste 300ASTUDIO ARCHITECTUREDenver, CO 80216theSTUDIOarchitecture.com866.529.9130COPYRIGHTPLOT DATE:CSTUDIO Project No:Sheet Issue & Revision LogIt is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client shall be responsible for any defects in construction if these procedures are not followed.NoDate DescriptionFOR REFERENCE ONLYDRAWN BY: REVIEWED BY:004-6006111/10/2023 6:42:46 PML130SITE LIGHTINGCALCULATIONS -400MULBERRY21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJBCheckerIMPALAREDEVELOPMENT1 04/13/22 PDP3 06/08/22 PDP RD 24 07/27/22 PDP RD 35 10/19/22 PDP RD 46 01/11/23 FDP RD 1FDP SUBMITTAL1" = 20'-0"L1301LIGHTING SITE PLAN PHOTOMETRICS - 400BS400P
1999 BROADWAYSUITE 2205DENVER, CO80202 | USA(T) 720 644 5044www.mazzetti.comProject Number:3575 Ringsby Ct, Ste 300ASTUDIO ARCHITECTUREDenver, CO 80216theSTUDIOarchitecture.com866.529.9130COPYRIGHTPLOT DATE:CSTUDIO Project No:Sheet Issue & Revision LogIt is the client's responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or client's subcontractors proceeding with the work. The client shall be responsible for any defects in construction if these procedures are not followed.NoDate DescriptionFOR REFERENCE ONLYDRAWN BY: REVIEWED BY:004-6006111/10/2023 6:42:47 PML200SITE LIGHTINGCUTSHEETS21-017.00306 & 400 IMPALA DRIVEFORT COLLINS, COJBBSIMPALAREDEVELOPMENT1 04/13/22 PDP3 06/08/22 PDP RD 24 07/27/22 PDP RD 35 10/19/22 PDP RD 46 01/11/23 FDP RD 1FDP SUBMITTALP