Loading...
HomeMy WebLinkAboutHULL ORCHARDS - PDP230002 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORT PRELIMINARY DRAINAGE AND EROSION CONTROL REPORT Hull Orchards Subdivision Prepared for: The True Life Companies 1601 19th Street, Suite 550 Denver, CO 80202 Prepared by: Wilson & Company 4065 St Cloud Drive, Suite 201 Loveland, Colorado 80538 970-834-6364 January 11, 2023 Job Number 22-100-449-00 4065 St. Cloud, Suite.201 Loveland, CO 80538 970-834-6364 phone January 11, 2023 Mr. Stephen Agenbroad City of Fort Collins Stormwater 700 Wood Street Fort Collins, CO 80522-0580 RE: Preliminary Drainage and Erosion Control Report for Hull Orchards Subdivision Dear Stephen, I am pleased to submit for your review and approval, this Preliminary Drainage and Erosion Control Report for Hull Orchards Subdivision. I certify that this report for the drainage design was prepared in accordance with the criteria in the Fort Collins Stormwater Criteria Manual. I appreciate your time and consideration in reviewing this submittal. Please call if you have any questions. Sincerely, Erika Schneider Michael Oberlander, P.E. Colorado Professional Engineer No. 41777 Colorado Professional Engineer No. 34288 4065 St. Cloud, Suite.201 Loveland, CO 80538 970-834-6364 phone ENGINEER’S CERTIFICATION “I hereby attest that this report for the final drainage design for the Hull Orchards Subdivision was prepared by me or under my direct supervision, in accordance with the provisions of the Fort Collins Stormwater Criteria Manual. I understand that the City of Fort Collins does not and will not assume liability for drainage facilities designed by others.” ____________________________________________ _______________________ Registered Professional Engineer Date Michael Oberlander, PE Registered Professional Engineer State of Colorado No. 34288 For and on behalf of Wilson & Company HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 1 of 17 Table of Contents 1. GENERAL LOCATION AND DESCRIPTION ................................................................. 2 1.1 Location ........................................................................................................................... 2 1.2 Description of Property ................................................................................................. 2 1.3 Floodplain Submittal Requirements ............................................................................ 2 2. DRAINAGE BASINS AND SUB-BASINS .......................................................................... 3 2.1 Major Basin Description ................................................................................................ 3 2.2 Sub-basin Description .................................................................................................... 3 3. DRAINAGE DESIGN CRITERIA ....................................................................................... 3 3.1 Regulations ...................................................................................................................... 3 3.2 Directly Connected Impervious Area (DCIA) Discussion .......................................... 3 3.3 Development Criteria Reference and Constraints ...................................................... 4 3.4 Hydrological Criteria ..................................................................................................... 5 3.5 Hydraulic Criteria .......................................................................................................... 7 3.6 Low Impact Development (LID) Conformance .......................................................... 7 3.7 Water Quality (WQ) Treatment Criteria .................................................................... 8 3.8 Detention Requirements ................................................................................................ 8 3.9 Floodplain Regulations Compliance ............................................................................. 8 3.10 Modifications of Criteria ............................................................................................... 8 4. DRAINAGE FACILITY DESIGN ....................................................................................... 8 4.1 General Concept ............................................................................................................. 8 4.2 Specific Details ................................................................................................................ 9 4.3 LID, WQ and Detention .............................................................................................. 13 5. SEDIMENT AND EROSION CONTROL ........................................................................ 15 6. CONCLUSIONS .................................................................................................................. 16 6.1 Compliance with Standards ........................................................................................ 16 6.2 Drainage Concept ......................................................................................................... 16 7. REFERENCES ..................................................................................................................... 17 APPENDIX A .............................................................................................................................................................. A VICINITY MAP AND DRAINAGE PLAN ........................................................................................................ A APPENDIX B .............................................................................................................................................................. B HYDROLOGIC COMPUTATIONS .................................................................................................................... B APPENDIX C .............................................................................................................................................................. C HYDRAULIC CALCULATIONS ....................................................................................................................... C APPENDIX D .............................................................................................................................................................. D LID, WATER QUALITY AND DETENTION POND ........................................................................................ D APPENDIX E .............................................................................................................................................................. E SOILS AND FLOODPLAIN INFORMATION ................................................................................................... E HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 2 of 17 1. GENERAL LOCATION AND DESCRIPTION 1.1 Location Hull Orchards Subdivision is located in the Northwest ¼ of Section 27, Township 7 North, Range 69 West of the 6th Principal Meridian, City of Fort Collins, County of Larimer, State of Colorado. It is generally bound to the west/south by fields and single-family homes, the north by Hull Street, and the east by Cedar Village 4th Filing and Silver Plume Estates Subdivisions. The Silver Plume Channel runs along the east edge of the site conveying water to a storm main which drains to Spring Creek. 1.2 Description of Property The site is approximately 12.7 acres and is mostly undeveloped with several buildings, gravel yard areas, and vegetation. The existing ground generally slopes from southwest to northeast at slopes of 0% to 3% towards the channel on the east of the site. The area is zoned as Planned Residential District. The project will consist of single-family homes and public streets with wet and dry utilities. Offsite flow contributes to the site from the west (the master plan basin shows all the land west of the site to Taft Hill Road drains to the Silver Plume Channel). The total offsite flow is calculated to be a total of 46 cfs. This development is required to accept and pass this existing offsite flow. The soils onsite mostly consist of Altvan-Satanta loams, 0 to 3 percent slopes, Soil Group B (95%). The remainder (5%) consists of Fort Collins loam, 3 to 5 percent slopes (Soil Group Type C). 1.3 Floodplain Submittal Requirements The area is designated as Zone X, Area of Minimal Flood Hazard, on FIRM Panel 08069C0986G, dated 5/02/2012 and is therefore not within any FEMA mapped floodplain. A Floodplain Submittal is not required and has not been included with this report. Please refer to Appendix E for the FEMA FIRMette. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 3 of 17 2. DRAINAGE BASINS AND SUB-BASINS 2.1 Major Basin Description The Hull Orchards Subdivision is part of the Spring Creek Drainage Basin. The basin is mostly residential development and includes parks, open space, and isolated industrial and commercial areas. 2.2 Sub-basin Description The property is located on the western half of the Spring Creek Drainage Basin and drains overland to the Silver Plume Channel that runs along the east edge of the site conveying water to a storm main (box culvert) which drains to Spring Creek. 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations This report was prepared to meet or exceed the “Fort Collins Stormwater Criteria Manual” (FCSCM) specifications. Where applicable, the criteria established in the Mile High Flood District’s (MHFD) “Urban Storm Drainage Criteria Manual” (USDCM), developed by the Denver Regional Council of Governments, has been used. 3.2 Directly Connected Impervious Area (DCIA) Discussion The USDCM recommends a four-step process for receiving water protection that focuses on reducing runoff volumes, treating the water quality capture volume (WQCV), stabilizing drainageways and implementing long-term source controls. The Four Step Process applies to the management of smaller, frequently occurring events. Step 1: Employ Runoff Reduction Practices To reduce runoff peaks, volumes, and pollutant loads from urbanizing areas, implement Low Impact Development (LID) strategies, including Minimizing Directly Connected Impervious Areas (MDCIA). Runoff from the site shall be conveyed to water quality facilities which promote settlement of particles and will slow the "first flush" from all storms entering the public street and storm sewer system. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 4 of 17 Step 2: Implement BMPs that Provide a Water Quality Capture Volume with Slow Release Runoff from the site shall be conveyed to water quality facilities which reduce the rate of runoff and promote settlement of particles. Step 3: Stabilize Drainageways Natural Drainageways are subject to bed and bank erosion due to increases in frequency, duration, rate and volume of runoff during and following development. Because the site will drain to an existing concrete lined drainage channel and storm system, bank stabilization is unnecessary with this project. Step 4: Implement Site Specific and Other Source Control BMPs The proposed project will control pollutants by encouraging them to settle out in water quality facilities before being released from the site. The proposed project will proactively control pollutants at their source by preventing pollution rather than removing contaminants once they have entered the stormwater system as compared to historic conditions. 3.3 Development Criteria Reference and Constraints The subject property is not part of any Overall Development Plan drainage study or similar “development/project” drainage master plan. The site is in the Spring Creek Master Drainage Basin. The only relevant previous study for this site is the City of Fort Collins’ Spring Creek Master Drainage Plan. The historic drainage for the site is based on this plan and proposed designs will conform to this plan. All basins in Fort Collins are required to provide LID water quality. This will be discussed in subsequent sections of the report. The stormwater outfall for this site is the Silver Plume Channel that runs along the east edge of the site conveying water to a storm main which drains to Spring Creek. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 5 of 17 3.4 Hydrological Criteria The City of Fort Collins requires that all drainage system design and construction take into consideration two design storms: the minor storm and the major storm. The “minor storm” is the 2-year storm or the 50th percentile storm event. The “major storm” is the 100-year storm or the one percentile storm event. Runoff computations were prepared for the 2-year minor and 100-year major storm frequencies utilizing the Rational Method. The study was divided into three offsite basins and fourteen onsite basins that can be identified on the Drainage Plan in Appendix A. Percentage impervious values were based on proposed land surface types and are specified in the following table from the FCSCM. Table 1. Recommended Percentage Imperviousness Values. The runoff coefficients ae based on surface type and specified in the following table from the FCSCM. The site is classified as NRCS Hydrologic Soil Group B. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 6 of 17 Table 2. Surface Type – Runoff Coefficients. The City of Fort Collins requires a Frequency Adjustment Factor for the 100-year Storm Return Period. The following table lists this factor, Cf. Table 3. Frequency Adjustment Factors. The rainfall intensities used in the Rational Method computation of runoff were obtained from the Fort Collins Rainfall IDF Curve contained in the figure below. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 7 of 17 Figure 1. Rainfall IDF Curve – Fort Collins. All hydrological calculations including a summary of the calculated minor and major rainfall event flows are provided in Appendix B. 3.5 Hydraulic Criteria All hydraulic calculations within this report have been prepared in accordance with the FCSCM and/or the USDCM. Final hydraulic calculations will be included in future submittals. 3.6 Low Impact Development (LID) Conformance Integration of LID systems into the drainage design is required for all development projects. The implementation of LID systems requires on of the following two options: 1. 50% of the newly added or modified impervious area must be treated by LID techniques and 25% of new paved (vehicle use) areas must be pervious. 2. 75% of newly added or modified impervious area must be treated by LID techniques. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 8 of 17 The project does not have any surface parking, so the 50% LID requirement with pavers was not available. Per discussions with City Staff, the 50% LID rule has been implemented on single family residential projects (because of the lack of any vehicular parking lots). This project will incorporate bioretention and Water Quality StormTech Chambers to accomplish treatment of 50% of the project’s new impervious area with LID. Please refer to the Existing vs Proposed Impervious Area Exhibit in Appendix D for comparison of the impervious areas. 3.7 Water Quality (WQ) Treatment Criteria Standard WQ treatment (40 hour drain time) is required for all portions of the development site that is not treated through LID systems. This will be accomplished in the WQ and Detention Pond located in the northeast portion of the subdivision. 3.8 Detention Requirements Onsite detention is required for the runoff volume difference between the 100-year developed inflow rate and the 2-year historic release rate. The SDI data spreadsheet will be provided in the final submittal package. 3.9 Floodplain Regulations Compliance The project is not within any FEMA mapped floodplain. Therefore, a Floodplain Submittal is not required and has not been included with this report. 3.10 Modifications of Criteria There are no Modifications of Criteria for this project. 4. DRAINAGE FACILITY DESIGN 4.1 General Concept The storm runoff of the proposed development will be collected and conveyed via proposed storm system to the proposed detention pond where it will be treated for water quality and detained before being released into Silver Plume Channel. 50% of the impervious area of the site will pass through either bioretention or underground water quality treatment HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 9 of 17 system. Details for LID water quality will continue to be developed as the project design progresses. 4.2 Specific Details A summary of the drainage patterns within each basin is provided in the following paragraphs. Please refer to Appendix A for the drainage plan. Basin OS1 is 1.93 acres and an offsite basin located west of Lots 1 and 10 of Block 1. This basin is analyzed to be 34% impervious and will produce 1.9 cfs and 8.8 cfs during the 2- year and 100-year events, respectively. This flow will be passed through the site via the curb and gutter of W. Swallow Road and Cherry Seed Lane to the inlets at Design Point E. The proposed storm system will then convey the flow to the proposed WQ and Detention Pond. The WQ and Detention Pond’s overflow spillway will pass this offsite flow to the Silver Plume Channel. Basin OS2 is 11.15 acres and an offsite basin located west of Attika Drive. This basin is analyzed to be 16% impervious and will produce 7.0 cfs and 30.7 cfs during the 2-year and 100-year events, respectively. This flow will be collected in an offsite area inlet and passed through the site via the proposed storm system to the proposed WQ and Detention Pond. The WQ and Detention Pond’s overflow spillway will pass this offsite flow to the Silver Plume Channel. The intent of the area inlet at Design Point OS2 is to serve as a future detention pond outlet when the lands to the west develop. Basin OS3 is 2.82 acres and an offsite basin located south of Hyline Drive and west of Cherry Seed Lane. This basin is analyzed to be 5% impervious and will produce 1.5 cfs and 6.5 cfs during the 2-year and 100-year events, respectively. This flow will sheet flow to the curb and gutter of Hyline Drive and Cherry Seed Lane to the inlet at Design Point C1. The proposed storm system will then convey the flow to the proposed WQ and Detention Pond. The WQ and Detention Pond’s overflow spillway will pass this offsite flow to the Silver Plume Channel. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 10 of 17 Basin A is 0.25 acres and is the west half of Attika Drive and its ROW. This basin is analyzed to be 75% impervious and will produce 0.6 cfs and 2.4 cfs during the 2-year and 100-year events, respectively. This flow will travel in the curb and gutter of Attika Drive to the sump inlet at Design Point A. Basin B is 0.23 acres and is the east half of Attika Drive and its ROW. This basin is analyzed to be 78% impervious and will produce 0.5 cfs and 2.2 cfs during the 2-year and 100-year events, respectively. This flow will travel in the curb and gutter of Attika Drive to the sump inlet at Design Point B. Basin C1 is 2.23 acres and contains the single-family lots 1-11 of Block 2 and the west half of the adjacent Cherry Seed Lane and all of Hyline Drive to the south. This basin is analyzed to be 54% impervious and will produce 3.8 cfs and 17.8 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the on-grade inlet at Design Point C1 located at the southwest corner of the intersection of Cherry Seed Land and W. Swallow Road. Overflow from this inlet will travel to the sump inlet at Design Point C4. This basin will also accept the flow from offsite Basin OS3. Basin C1 includes a portion of future Cherry Seed Lane that is not proposed to be built at this time (it is not on the development parcel), but it will be impossible for future development to capture and treat this future right of way. This section of street has been included in the treatment and detention calculations. Basin C2 is 1.05 acres and contains the east half of Cherry Seed Lane and the adjacent single-family lots 1-8 of Block 3. This basin is analyzed to be 78% impervious and will produce 2.4 cfs and 10.4 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the on-grade inlet at Design Point C2 located at the southeast corner of the intersection of Cherry Seed Land and W. Swallow Road. Overflow from this inlet will travel to the sump inlet at Design Point C4. Basin C2 includes a portion of future Cherry Seed Lane that is not proposed to be built at this time (it is not on the development parcel), but it will be impossible for future development to capture and treat this future right of way. This section of street has been included in the treatment and detention calculations. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 11 of 17 Basin C3 is 1.18 acres and contains the single-family lots 9-16 of Block 3 and the west half of the adjacent Morello Drive. This basin is analyzed to be 48% impervious and will produce 2.0 cfs and 8.8 cfs during the 2-year and 100-year events, respectively. This basin will also accept the overflow from the on-grade inlet at Design Point C5. This flow will be captured by the on-grade inlet at Design Point C3 located at the southwest corner of the intersection of Morello Drive and W. Swallow Road. Overflow from this inlet will travel to the sump inlet at Design Point C4. Basin C4 is 2.27 acres and contains the entire single-family lots 1-8 of Block 4, the south half of W. Swallow Road, the east half of adjacent Morello Drive as well as the back portion of lots 9-13 of Block 4. This basin is analyzed to be 67% impervious and will produce 4.7 cfs and 20.7 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the sump inlet at Design Point C4 located on W. Swallow Road to the east of the intersection with Morello Drive. Overflow from the inlets at Design Points C1, C2 and C3 will also travel to and be captured in this inlet. A shallow channel is proposed in Tract E to convey flows north and to drainage facilities so that this flow is treated and detained and does not flow directly into the Silver Plume Channel. Basin C5 is 1.31 acres and contains the single-family Lots 1-11 of Block 2, Benton Lane, Tulare Drive and the west half of the adjacent Morello Drive. This basin is analyzed to be 57% impervious and will produce 2.3 cfs and 10.7 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the on-grade inlet at Design Point C5 located on Morello Drive to the north of the intersection with Benton Lane. Overflow from this inlet will travel to the on-grade inlet at Design Point C3. Basin C6 is 0.34 acres and contains the front portion of the single-family Lots 9-13 of Block 4 and the east half of adjacent Morello Drive. This basin is analyzed to be 54% impervious and will produce 0.7 cfs and 3.2 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the on-grade inlet at Design Point C6 that is located on Morello Drive east of the inlet at Design Point C5. Overflow from this inlet will travel to the sump inlet at Design Point C4. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 12 of 17 Basin D is 0.26 acres and contains the north half of W. Swallow Road from Cherry Seed Lane. This basin is analyzed to be 79% impervious and will produce 0.6 cfs and 2.6 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the sump inlet at Design Point D that is located on W. Swallow Road north of the inlet at Design Point C4. Basin E is 2.08 acres and contains the single-family lots 1-10 of Block 1, the north half of adjacent W. Swallow Road, the south half of adjacent Hull Street and the west half of adjacent Cherry Seed Lane. This basin is analyzed to be 55% impervious and will produce 3.3 cfs and 15.5 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the sump inlet at Design Point E. Overflow from this inlet will travel to the sump inlet at Design Point C4. This basin will also accept the flow from offsite Basin OS1. Basin F is 0.19 acres and contains the east half the adjacent Cherry Seed Lane. This basin is analyzed to be 75% impervious and will produce 0.4 cfs and 1.9 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the sump inlet at Design Point F. Basin G is 0.34 acres and contains the north half of Hull Street. This basin is analyzed to be 74% impervious and will produce 0.7 cfs and 3.2 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the on-grade inlet at Design Point G. There is no overflow at this inlet. Basin H is 0.14 acres and contains the south half of Hull Street to the east of Cherry Seed Lane. This basin is analyzed to be 73% impervious and will produce 0.3 cfs and 1.3 cfs during the 2-year and 100-year events, respectively. This flow will be captured by the on- grade inlet at Design Point H. There is no overflow at this inlet. Basin I is 1.68 acres and contains the proposed park and pond area. This basin is analyzed to be 6% impervious and will produce 1.0 cfs and 4.2 cfs during the 2-year and 100-year events, respectively. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 13 of 17 All proposed inlets will drain to proposed storm systems that will convey flow to the proposed WQ and Detention Pond located in the northeast portion of the subdivision. 4.3 LID, WQ and Detention The project is required to treat 50% of new impervious area with LID. For this initial submittal, locations for LID treatment have been identified, but specific design has not been completed. The basins within the development (excluding the detention pond in basin I) average 62% impervious. Appendix D includes preliminary calculations for LID treatment. This was accomplished by multiplying the area flowing to the LID facility by the average 62% impervious. The following five (5) LID areas have been identified: Bioretention A - Block 1 (NW portion of project) – this area can be routed from the back yard drainage of the homes and a curb chase / sidewalk culvert on the north side of Swallow to a surface facility in Tract A. The bioretention underdrain will be piped to Design Point E. Bioretention B – Swallow and east portion of Morello Drive – this area can be routed to the inlets at Design Points C4 and D and routed to a proposed LID area in the southeast corner of the detention pond. A baffle or other method to only take initial flows to the LID from the inlet at Design Point D will be designed with future efforts. Bioretention C - Block 2 (SW portion of project) – this area can be routed from the back yard drainage of the homes and a curb chase / sidewalk culvert on the south side of Swallow to a surface facility in Tract C. The bioretention underdrain will be piped to Design Point C1. Bioretention D - Block 5 (southmost portion of project) – this area can be routed from the back yard drainage of the homes and a curb chase / sidewalk culverts on the adjacent streets to a small facility at the corner of Benton Lane and Morello Drive. The bioretention underdrain will be piped to Design Point C5. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 14 of 17 Underground Water Quality System E - Block 4 and Tract E (east portion of project and multi-use trail) – this area drains from south to north and Tract E can be used for surface conveyance of flows. A Storm Tech facility can be placed at the north end of Tract E with multiple small inlets near the trail to collect the minor flows. This dual purpose of this land is ideal for both the trail and the underground facility since it will not ever have any impediments to access for maintenance. The above LID is estimated to treat 53% of the project’s new impervious area. An Extended Detention outlet structure will still be placed on the detention pond outlet to treat the remaining area that is not treated by LID. Currently the entire site’s water quality capture volume has been accounted for in the pond (not reduced because of LID treatment). This will be more finely designed with future submittals. Detention is also provided in Basin I (Tract D) to reduce the developed project flows from the 100-year storm to the 2- year historic release (6.7 cfs). The outlet structure will be tied to the invert of the Silver Plume Channel at the northeast corner of the site. The concrete trail on the east side of the pond has been sized for the entire 100-year project flow plus the 46 CFS of offsite flow. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 15 of 17 The following table is a summary of the preliminary WQ and Detention Pond: 5. SEDIMENT AND EROSION CONTROL The disturbed area is greater than 1 acre and will require a State of Colorado Discharge Permit and City of Fort Collins plan and report. Temporary Sediment and Erosion Control Erosion and sedimentation will be controlled on-site during construction by use of vehicle tracking control pad, concrete washout area, silt fence, rock socks in adjacent existing curb and gutter, inlet protection, sediment control logs in swales, and seeding and mulch. The measures will be designed to limit the overall sediment yield increase due to construction as required by the City of Fort Collins. During grading, the soil will be roughened and furrowed perpendicular to the prevailing winds. During the performance of the work required by these specifications or any operations appurtenant thereto, whether on right-of-way provided by the City or elsewhere, the contractor shall furnish all labor, equipment, materials, and means required to comply with HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 16 of 17 applicable permits. The Contractor shall carry out proper efficient measures wherever and as necessary to reduce dust nuisance, and to prevent dust nuisance that has originated from his operations from damaging crops, orchards, cultivated fields, and dwellings, or causing naissance to persons. The Contractor will be held liable for any damage resulting from dust originating from his operations under these specifications on right-of-way or elsewhere. Wherever construction vehicles access routes or intersect paved public roads, provisions must be made to minimize the transport of sediment by runoff or vehicles tracking onto the paved surface. The contractor will be responsible for clearing mud tracked onto city streets on a daily basis. All temporary erosion and sediment control practices must be maintained and repaired as needed to assure continued performance of their intended function. An Erosion Control Report will be submitted during Final Compliance. 6. CONCLUSIONS 6.1 Compliance with Standards All computations that have been completed within this report are in compliance with the City of Fort Collins Storm Drainage Design Criteria Manual. 6.2 Drainage Concept The proposed drainage concepts presented in this report and on the preliminary construction plans adequately provide for stormwater quantity and quality treatment of proposed impervious areas. Conveyance elements have been designed to pass required flows and to minimize future maintenance. If, at the time of construction, groundwater is encountered, a Colorado Department of Health Construction Dewatering Permit will be required. HULL ORCHARDS SUBDIVISION 4065 Saint Cloud Drive; Suite 201, Loveland, CO 80538 phone: 970.834.6364 Page 17 of 17 7. REFERENCES 1. City of Fort Collins, “Fort Collins Stormwater Criteria Manual”, adopted December 2018. 2. Mile High Flood District, “Urban Storm Drainage Criteria Manual”, Volumes 1 and 2, updated January 2016, and Volume 3 updated November 2010. A APPENDIX A VICINITY MAP DRAINAGE PLAN SITEhull orchards subdivisionviciniW\ PaSScale: 1"=1000' STOHU OHU OHU OHU OHU OHU STS S C.O. W S C WCVAULT CABLEELEC VAULT CABLE ELEC HY DFE SFE S M S HY DVAULT ELEC ELEC HY DW WW S S SS FO HY DVAULT ELEC VAULT F.O. VAULT F.O. VAULT F.O.VAULT ELEC VAULT F.O. E G VAULT F.O. VAULT F.O. C C VAULT F.O. VAULT F.O.9'UE TYP.10' TYPE R INLET Q100 C/O=3.3 CFS TO DP C3 EX 4' X 11' BOX CULVERT EX 4' CONCRETE PAN EX 4' CONCRETE PAN Q100=8.8 CFS AREA INLET Q100=30.7 CFS Q100=6.5 CFS 10' TYPE R INLET 5' TYPE R INLET 5' TYPE R INLET 15' TYPE R INLET Q100 C/O=7.9 CFS TO DP C4 10' TYPE R INLET Q100 C/O=2.7 CFS TO DP C4 5' TYPE R INLET 10' TYPE R INLET 5' TYPE R INLET 15' TYPE R INLET 10' TYPE R INLET Q100 C/O=4.2 CFS TO DP C4 PROP 4' X 11' BOX CULVERT PROP OUTLET STRUCTURE 5' TYPE R INLET 10' TYPE R INLET 2' CONC PAN 2' CONC PAN Q100 RELEASE RATE=6.7 CFS HYLINE DRIVE LOT 1 BLOCK 1 LOT 2 LOT 3 LOT 4 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 BLOCK 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 TRACT F (DE) BLOCK 5 BLOCK 3 BLOCK 4 ATTIKA DRIVECHERRY SEED LANEMORELLO DRIVEBENTON LANE TULARE DRIVECHERRY SEED LANEW SWALLOW RD LOT 10 SILVER PLUME ESTATES HYLINE DRIVE HULL STREET SOUTH TAFT RDW SWALLOW RD HULL STREET TRACT A (AE, DE, UE) WQ AND DETENTION POND TRACT C (DE) TRACT D (DE) TRACT E (PE, DE) TRACT E (PE, DE) TRACT E (PE, DE) CEDAR VILLAGE 4TH FILING SILVER PLUME ESTATES CRAWS RESUBDIVISION 1 2 3 4 5 6 7 8 9 FISCH DR. PART OF LOTS 5 & 6 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOTS 9 & 7 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOT 10 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOTS 5 & 6 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOTS 5 & 6 SUB. OF W 1 2 OF NW 1 4 27-7N-29W HULL ST.TRACT A (CITY) LOT 3 SUB. OF W 1 2 OF NW 1 4 27-7N-29W LOT 2 SUB. OF W 1 2 OF NW 1 4 27-7N-29W LOT 1 SUB. OF W 1 2 OF NW 1 4 27-7N-29W 10 SILVERPLUME ESTATES SILVERPLUME ESTATES CEDAR VILLAGE 4TH FILING 7 8 9 10 11 12 13 14 15 16 61 62 63 64 65KINNISON DR. CRAWS RESUBDIVISION PART OF LOTS 5 & 6 SUB. OF W 1 2 OF NW 1 4 27-7N-29W TRACT B (PE, DE)5090508550805 0 7 5 5 0 9 05090 5085 508550905090 509550905 0 9 0 50955090509 0 508550905085 5 0 8 0 5080 5080 50855085509050905095509 5 509551005 0 9 55100 5100 5 1 0 5 50 9 5 50 9 0509550905 0 9 0 50 9 0 509550855085 50755075508050805 0 8 05080508550905095 50805080508550855090 50 9 5 51 0 0510551 1 0 20' CURB RETURN (TYP) 20' CURB RETURN (TYP) EX SILVER PLUME CHANNEL EX SILVER PLUME CHANNEL SILVERPLUME ESTATESTRACT A (CITY)TRACT B100 YR WSEL=5079.2 144 LF EMERGENCY OVERFLOW SPILLWAY=5079.5 57' ROW 57' ROW 57' ROW 57' ROW 57'ROW57'ROW69' ROWEX 60'ROW57' ROWEX30'ROWEX 40' AEEX 30' ROWEX 60' ROWEX 68' ROWEX 60' ROW DRAINAGE PLAN 12 MPO ES ES 22-100-449-00 JANUARY 11, 20234065 SAINT CLOUD DRIVE, SUITE 201LOVELAND, CO 80538PHONE: 970-834-6364www.wilsonco.comDRAWN BY: CHECKED BY: DATE:DESCRIPTIONDATEPROPERTY OWNERSEALPROJECT NAMEPROJECT NO: DESIGNED BY: SHEET NO: SHEET TITLE REV.BYPRE LI MI N A R Y S U B MI T T A L NOT F O R CON S T R U C TI O N HULL ORCHARDSSUBDIVISIONEXISTING MAJOR CONTOUR BASIN COEFFICIENT (100-YR) DRAINAGE BASIN AREA DRAINAGE BASIN NUMBER DESIGN POINT PROPOSED DRAINAGE BASIN DIVIDE LINE FLOW PATH LEGEND EXISTING MINOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR THE TRUE LIFE COMPANIES1601 19TH ST. SUITE 550DENVER, CO 80202 B APPENDIX B HYDROLOGIC COMPUTATIONS DRAINAGE SUMMARY TABLEDesign Tributary Area C (2) C (100) tc (2) tc (100) Q(2)tot Q(100)totSub-basinREMARKSPoint (ac)(min) (min) (cfs) (cfs)1 OS1 1.93 0.49 0.61 12.8 11.0 1.9 8.8 W. Swallow Road2 OS2 11.15 0.36 0.45 16.7 16.7 7.0 30.7 Type C Inlet3 OS3 2.82 0.27 0.34 13.9 13.9 1.5 6.5 Cherry Seed LaneA A 0.25 0.77 0.97 5.0 5.0 0.6 2.4 5' Type R Inlet (sump)B B 0.23 0.79 0.99 5.0 5.0 0.5 2.2 5' Type R Inlet (sump)C1 C1 2.23 0.64 0.80 5.8 5.0 5.3 24.3 15' Type R Inlet (on-grade)C2 C2 1.05 0.81 1.00 5.2 5.0 2.4 10.4 10' Type R Inlet (on-grade)C3 C3 1.18 0.60 0.75 5.1 5.0 2.0 12.1 10' Type R Inlet (on-grade)C4 C4 2.27 0.73 0.92 5.0 5.0 4.7 35.5 15' Type R Inlet (sump)C5 C5 1.31 0.66 0.82 5.7 5.0 2.3 10.7 10' Type R Inlet (on-grade)C6 C6 0.34 0.75 0.94 5.0 5.0 0.7 3.2 10' Type R Inlet (on-grade)D D 0.26 0.80 1.00 5.0 5.0 0.6 2.6 5' Type R Inlet (sump)E E 2.08 0.64 0.80 7.3 6.0 5.2 24.3 10' Type R Inlet (sump)F F 0.19 0.77 0.96 5.0 5.0 0.4 1.9 5' Type R Inlet (sump)G G 0.34 0.76 0.96 5.0 5.0 0.7 3.2 10' Type R Inlet (on-grade)H H 0.14 0.76 0.95 5.0 5.0 0.3 1.3 5' Type R Inlet (on-grade)I I 1.68 0.28 0.35 12.0 12.0 1.0 4.2 WQ and Detention Pond230109 COFC FLOW.xlsB01 RUNOFF COEFFICIENTS & % IMPERVIOUS LOCATION:Hull Orchards Subdivision PROJECT NO:22-100-449-00 COMPUTATIONS BY:es DATE:12/14/2022 Recommended Runoff Coefficients from Table 3.2-2 of City of Fort Collins Stormwater Criteria Manual Recommended % Impervious from Table 4.1-3 of City of Fort Collins Stormwater Criteria Manual Type B soils Runoff % coefficient Impervious C Asphalt, Concrete 0.95 100 Rooftop 0.95 90 Gravel or Pavers: 0.50 40 Lawns (clayey 2%-7%) : 0.25 2 SUBBASIN TOTAL TOTAL PAVED ROOF GRAVEL LANDSCAPE RUNOFF % DESIGNATION AREA AREA AREA AREA AREA AREA COEFF. Impervious Remarks (ac.) (sq.ft) (sq.ft) (sq.ft) (sq.ft) (sq.ft) (C) OS1 1.93 84,095 10,032 13,668 13,336 47,058 0.49 34 OS2 11.15 485,834 17,264 44,078 35,565 388,928 0.36 16 OS3 2.82 122,846 0 0 10,882 111,964 0.27 5 A 0.25 10,932 8,175 0 0 2,757 0.77 75 B 0.23 9,879 7,667 0 0 2,212 0.79 78 C1 2.23 97,280 32,245 22,000 0 43,035 0.64 54 C2 1.05 45,704 20,861 16,000 0 8,843 0.81 78 C3 1.18 51,610 9,607 16,000 0 26,003 0.60 48 C4 2.27 98,780 40,934 26,000 3,230 28,616 0.73 67 C5 1.31 57,064 23,153 10,000 0 23,911 0.66 57 C6 0.34 15,003 10,805 0 0 4,199 0.75 73 D 0.26 11,338 8,943 0 0 2,395 0.80 79 E 2.08 90,396 30,590 20,000 0 39,806 0.64 55 F 0.19 8,447 6,273 0 0 2,174 0.77 75 G 0.34 14,608 10,738 0 0 3,870 0.76 74 H 0.14 6,130 4,465 0 0 1,665 0.76 73 I 1.68 73,064 2,799 0 1,249 69,016 0.28 6 A thru I 13.55 590,235 217,254 110,000 4,478 258,503 0.64 55 Historic A thru I 13.55 590,235 3,374 8,100 54,390 524,371 0.29 7 Equations - Calculated C coefficients & % Impervious are area weighted C = S (Ci Ai) / At Equation 5-2 Ci = runoff coefficient for specific area, Ai Ai = areas of surface with runoff coefficient of Ci n = number of different surfaces to consider At = total area over which C is applicable; the sum of all Ai's 230109 COFC FLOW.xls B02 STANDARD FORM SF-2 TIME OF CONCENTRATION - 2 and 10 YR LOCATION: Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 12/14/2022 2 and 10-yr storm Cf = 1.00 from Table RO-12 of City of Fort Collins Stormwater Code, Volume I SUB-BASIN INITIAL /OVERLAND TRAVEL TIME / GUTTER OR CHANNEL FLOW tc CHECK FINAL REMARKS DATA TIME (ti) (tt)(URBANIZED BASIN) tc DESIGN SUBBASIN(s) Area C Length Slope ti Length Slope n Vel. tt tc = Total L tc=(l/180)+10 PONIT (ac) (ft) (%) (min) (ft) (%) Manning (ft/s) (min) ti + tt (ft) (min) (min) (1) (2) (3) (4) (5) (6) (7) (8) rough. (9) (10) (11) (12) (13) (14) 1 OS1 1.93 0.49 100 2.0 9.1 500 2.0 0.02 2.3 3.7 12.8 600 13.3 12.8 2 OS2 11.15 0.36 200 2.0 15.6 1000 2.0 0.02 2.3 7.3 22.9 1200 16.7 16.7 3 OS3 2.82 0.27 200 2.0 17.4 500 2.0 0.03 1.5 5.5 22.9 700 13.9 13.9 A A 0.25 0.77 29 2.0 2.6 179 3.2 0.012 4.8 0.6 3.2 208 11.2 5.0 B B 0.23 0.79 29 2.0 2.5 179 3.2 0.012 4.8 0.6 3.1 208 11.2 5.0 C1 C1 2.23 0.64 15 2.0 2.6 640 1.6 0.012 3.4 3.1 5.8 655 13.6 5.8 C2 C2 1.05 0.81 24 2.0 2.1 640 1.6 0.012 3.4 3.1 5.2 664 13.7 5.2 C3 C3 1.18 0.60 21 2.0 3.4 367 1.9 0.012 3.7 1.7 5.1 388 12.2 5.1 C4 C4 2.27 0.73 21 2.0 2.5 500 1.9 0.012 3.7 2.3 4.8 521 12.9 5.0 C5 C5 1.31 0.66 30 2.0 3.6 420 1.5 0.012 3.3 2.1 5.7 450 12.5 5.7 C6 C6 0.34 0.75 21 2.0 2.4 279 1.5 0.012 3.3 1.4 3.8 300 11.7 5.0 D D 0.26 0.80 33 2.0 2.5 199 1.3 0.012 3.1 1.1 3.6 232 11.3 5.0 E E 2.08 0.64 33 2.0 3.9 412 0.6 0.012 2.0 3.4 7.3 445 12.5 7.3 F F 0.19 0.77 31 2.0 2.7 163 0.6 0.012 2.0 1.4 4.1 194 11.1 5.0 G G 0.34 0.76 24 2.0 2.4 494 2.0 0.012 3.8 2.2 4.6 518 12.9 5.0 H H 0.14 0.76 31 2.0 2.8 193 2.0 0.012 3.8 0.8 3.7 224 11.2 5.0 I I 1.68 0.28 250 2.0 19.2 114 2.0 0.012 3.8 0.5 19.7 364 12.0 12.0 A thru I 13.55 0.64 15 2.0 2.6 1170 0.9 0.012 2.5 7.7 10.3 1185 16.6 10.3 Historic A thru I 13.55 0.29 200 2.0 17.1 1170 0.9 0.025 1.2 16.0 33.1 1370 17.6 17.6 EQUATIONS:Overland Flow Length tc = ti + tt Equation 5-3 L=200' Max in developed areas L=500' Max in undeveloped areas ti = [1.87 (1.1 - CCf ) L0.5 ] / S 1/3 Equation 3.3-2 tt = L/(V*60)Equation 5-5 V=1.49/n * R^2/3*S^1/2 Equation 5-4 final tc = minimum of ti + tt and urbanized basin check min. tc = 5 min. due to limits of IDF curves 230109 COFC FLOW.xls B03 STANDARD FORM SF-2 TIME OF CONCENTRATION - 100 YR LOCATION: Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 12/14/2022 100-yr storm Cf = 1.25 from Table RO-12 of City of Fort Collins Stormwater Code, Volume I SUB-BASIN INITIAL /OVERLAND TRAVEL TIME / GUTTER OR CHANNEL FLOW tc CHECK FINAL REMARKS DATA TIME (ti)(tt)(URBANIZED BASIN) tc DESIGN SUBBASIN(s) Area C C*Cf Length Slope ti Length Slope n Vel. tt tc = Total L tc=(l/180)+10 PONIT (ac)(ft) (%) (min) (ft) (%) Manning (ft/s) (min) ti + tt (ft) (min) (min) (1) (2) (3) (4) (5) (6) (7) (8) rough. (9) (10) (11) (12) (13) (14) 1 OS1 1.93 0.49 0.61 100 2.0 7.3 500 2.0 0.020 2.3 3.7 11.0 600 13.3 11.0 2 OS2 11.15 0.36 0.45 200 2.0 13.7 1000 2.0 0.020 2.3 7.3 21.1 1200 16.7 16.7 3 OS3 2.82 0.27 0.34 200 2.0 16.0 500 2.0 0.030 1.5 5.5 21.5 700 13.9 13.9 A A 0.25 0.77 0.97 29 2.0 1.1 179 3.2 0.012 4.8 0.6 1.7 208 11.2 5.0 B B 0.23 0.79 0.99 29 2.0 0.9 179 3.2 0.012 4.8 0.6 1.5 208 11.2 5.0 C1 C1 2.23 0.64 0.80 15 2.0 1.7 640 1.6 0.012 3.4 3.1 4.9 655 13.6 5.0 C2 C2 1.05 0.81 1.00 24 2.0 0.7 640 1.6 0.012 3.4 3.1 3.9 664 13.7 5.0 C3 C3 1.18 0.60 0.75 21 2.0 2.4 367 1.9 0.012 3.7 1.7 4.1 388 12.2 5.0 C4 C4 2.27 0.73 0.92 21 2.0 1.3 500 1.9 0.012 3.7 2.3 3.5 521 12.9 5.0 C5 C5 1.31 0.66 0.82 30 2.0 2.3 420 1.5 0.012 3.3 2.1 4.4 450 12.5 5.0 C6 C6 0.34 0.75 0.94 21 2.0 1.1 279 1.5 0.012 3.3 1.4 2.5 300 11.7 5.0 D D 0.26 0.80 1.00 33 2.0 0.9 199 1.3 0.012 3.1 1.1 1.9 232 11.3 5.0 E E 2.08 0.64 0.80 33 2.0 2.5 412 0.6 0.012 2.0 3.4 6.0 445 12.5 6.0 F F 0.19 0.77 0.96 31 2.0 1.1 163 0.6 0.012 2.0 1.4 2.5 194 11.1 5.0 G G 0.34 0.76 0.96 24 2.0 1.0 494 2.0 0.012 3.8 2.2 3.2 518 12.9 5.0 H H 0.14 0.76 0.95 31 2.0 1.2 193 2.0 0.012 3.8 0.8 2.1 224 11.2 5.0 I I 1.68 0.28 0.35 250 2.0 17.6 114 2.0 0.012 3.8 0.5 18.1 364 12.0 12.0 A thru I 13.55 0.64 0.80 15 2.0 1.7 1170 0.9 0.012 2.5 7.7 9.4 1185 16.6 9.4 Historic A thru I 13.55 0.29 0.36 200 2.0 15.6 1170 0.9 0.025 1.2 16.0 31.6 1370 17.6 17.6 EQUATIONS:Overland Flow Length tc = ti + tt Equation 5-3 L=200' Max in developed areas L=500' Max in undeveloped areas ti = [1.87 (1.1 - CCf ) L0.5 ] / S 1/3 Equation 3.3-2 tt = L/(V*60)Equation 5-5 V=1.49/n * R^2/3*S^1/2 Equation 5-4 final tc = minimum of ti + tt and urbanized basin check min. tc = 5 min. due to limits of IDF curves 230109 COFC FLOW.xls B04 RATIONAL METHOD PEAK RUNOFF (City of Fort Collins, 2-Yr Storm) LOCATION: Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 12/14/2022 2 yr storm, Cf = 1.00 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Design Tributary A C Cf tc i Q (2) from Q (2) Q(2)tot Sub-basin Design Point (ac) (min) (in/hr) (cfs) Point (cfs) (cfs) 1 OS1 1.93 0.49 12.8 2.01 1.9 1.9 W. Swallow Road 2 OS2 11.15 0.36 16.7 1.77 7.0 7.0 Type C Inlet 3 OS3 2.82 0.27 13.9 1.93 1.5 1.5 Cherry Seed Lane A A 0.25 0.77 5.0 2.85 0.6 0.6 5' Type R Inlet (sump) B B 0.23 0.79 5.0 2.85 0.5 0.5 5' Type R Inlet (sump) C1 C1 2.23 0.64 5.8 2.69 3.8 OS3 1.5 5.3 15' Type R Inlet (on-grade) C2 C2 1.05 0.81 5.2 2.77 2.4 2.4 10' Type R Inlet (on-grade) C3 C3 1.18 0.60 5.1 2.79 2.0 2.0 10' Type R Inlet (on-grade) C4 C4 2.27 0.73 5.0 2.85 4.7 4.7 15' Type R Inlet (sump) C5 C5 1.31 0.66 5.7 2.69 2.3 2.3 10' Type R Inlet (on-grade) C6 C6 0.34 0.75 5.0 2.85 0.7 0.7 10' Type R Inlet (on-grade) D D 0.26 0.80 5.0 2.85 0.6 0.6 5' Type R Inlet (sump) E E 2.08 0.64 7.3 2.49 3.3 OS1 1.9 5.2 10' Type R Inlet (sump) F F 0.19 0.77 5.0 2.85 0.4 0.4 5' Type R Inlet (sump) G G 0.34 0.76 5.0 2.85 0.7 0.7 10' Type R Inlet (on-grade) H H 0.14 0.76 5.0 2.85 0.3 0.3 5' Type R Inlet (on-grade) I I 1.68 0.28 12.0 2.06 1.0 1.0 WQ and Detention Pond A thru I 13.55 0.64 10.3 2.20 19.1 19.1 Historic A thru I 13.55 0.29 17.6 1.72 6.7 6.7 Q = Cf C iA Q = peak discharge (cfs) C = runoff coefficient Cf = frequency adjustment factor i = rainfall intensity (in/hr) from City of Fort Collins IDF curve A = drainage area (acres)i = 24.221 / (10+ tc)0.7968 230109 COFC FLOW.xls B05 RATIONAL METHOD PEAK RUNOFF (City of Fort Collins, 100-Yr Storm) LOCATION: Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 12/14/2022 100 yr storm, Cf = 1.25 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Des. Area A C Cf tc i Q (100) from Q (100) Q(100)tot Design Point Design.(ac)(min)(in/hr)(cfs)Point (cfs)(cfs) 1 OS1 1.93 0.61 11.0 7.48 8.8 8.8 W. Swallow Road 2 OS2 11.15 0.45 16.7 6.17 30.7 30.7 Type C Inlet 3 OS3 2.82 0.34 13.9 6.74 6.5 6.5 Cherry Seed Lane A A 0.25 0.97 5.0 9.95 2.4 2.4 5' Type R Inlet (sump) B B 0.23 0.99 5.0 9.95 2.2 2.2 5' Type R Inlet (sump) C1 C1 2.23 0.80 5.0 9.95 17.8 OS3 6.5 24.3 15' Type R Inlet (on-grade) C2 C2 1.05 1.00 5.0 9.95 10.4 10.4 10' Type R Inlet (on-grade) C3 C3 1.18 0.75 5.0 9.95 8.8 C5 3.3 12.1 10' Type R Inlet (on-grade) C4 C4 2.27 0.92 5.0 9.95 20.7 C1+C2+C3 14.8 35.5 15' Type R Inlet (sump) C5 C5 1.31 0.82 5.0 9.95 10.7 10.7 10' Type R Inlet (on-grade) C6 C6 0.34 0.94 5.0 9.95 3.2 3.2 10' Type R Inlet (on-grade) D D 0.26 1.00 5.0 9.95 2.6 2.6 5' Type R Inlet (sump) E E 2.08 0.80 6.0 9.30 15.5 OS1 8.8 24.3 10' Type R Inlet (sump) F F 0.19 0.96 5.0 9.95 1.9 1.9 5' Type R Inlet (sump) G G 0.34 0.96 5.0 9.95 3.2 3.2 10' Type R Inlet (on-grade) H H 0.14 0.95 5.0 9.95 1.3 1.3 5' Type R Inlet (on-grade) I I 1.68 0.35 12.0 7.19 4.2 4.2 WQ and Detention Pond A thru I 13.55 0.80 9.4 7.96 86.3 86.3 Historic A thru I 13.55 0.36 17.6 6.01 29.2 29.2 Q = C iA Q = peak discharge (cfs) C = runoff coefficient i = rainfall intensity (in/hr) from City of Fort Collins IDF curve A = drainage area (acres)i = 84.682 / (10+ tc)0.7975 230109 COFC FLOW.xls B06 City of Fort Collins Stormwater Criteria Manual B07 City of Fort Collins Stormwater Criteria Manual B08 C APPENDIX C HYDRAULIC CALCULATIONS C01 Purpose:This workbook can be used to size a variety of inlets based on allowable spread and depth in a street or swale. Function:1. To calculate peak discharge for the tributary area to each inlet. 2. To calculate allowable half-street capacity based on allowable depth and spread. 3. To determine the inlet capacity for selected inlet types. 4. To manage inlet information and connect inlets in series to account for bypass flow. Content:The workbook consists of the following sheets: Q-Peak Inlet Management Inlet [#] Inlet Pictures Acknowledgements:Spreadsheet Development Team: Ken A. MacKenzie, P.E., Holly Piza, P.E., Chris Carandang Mile High Flood District Derek N. Rapp, P.E. Peak Stormwater Engineering, LLC Dr. James C.Y. Guo, Ph.D., P.E. Professor, Department of Civil Engineering, University of Colorado at Denver Comments?Direct all comments regarding this spreadsheet workbook to:MHFD E-mail Revisions?Check for revised versions of this or any other workbook at:Downloads Imports information from the Q-Peak sheet and Inlet [#] sheets and can be used to connect inlets in series so that bypass flow from an upstream inlet is added to flow calculated for the next downstream inlet. This sheet can also be used to modify design information from the Q-peak sheet. Inlet [#] sheets are created each time the user exports information from the Q-Peak sheet to the Inlet Management sheet. The Inlet [#] sheets calculate allowable half-street capacity based on allowable depth and allowable spread for the minor and major storm events. This is also where the user selects an inlet type and calculates the capacity of that inlet. Contains a library of photographs of the various types of inlets contained in MHFD-Inlet and referenced in the USDCM. Calculates the peak discharge for the inlet tributary area based on the Rational Method for the minor and major storm events. Alternatively, the user can enter a known flow. Information from this sheet is then exported to the Inlet Management sheet. STREET AND INLET HYDRAULICS WORKBOOK MHFD-Inlet, Version 5.01 (April 2021) Mile High Flood District Denver, Colorado www.mhfd.org 1 C02 MHFD-Inlet, Version 5.01 (April 2021) Worksheet Protected INLET NAME Inlet G Inlet H Inlet E Site Type (Urban or Rural)URBAN URBAN URBAN Inlet Application (Street or Area) STREET STREET STREET Hydraulic Condition On Grade On Grade In Sump Inlet Type CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening USER-DEFINED INPUT User-Defined Design Flows Minor QKnown (cfs)0.7 0.3 5.2 Major QKnown (cfs)3.2 1.3 24.3 Bypass (Carry-Over) Flow from Upstream Receive Bypass Flow from: No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received Minor Bypass Flow Received, Qb (cfs)0.0 0.0 0.0 Major Bypass Flow Received, Qb (cfs)0.0 0.0 0.0 Watershed Characteristics Subcatchment Area (acres) Percent Impervious NRCS Soil Type Watershed Profile Overland Slope (ft/ft) Overland Length (ft) Channel Slope (ft/ft) Channel Length (ft) Minor Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) Major Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) CALCULATED OUTPUT Minor Total Design Peak Flow, Q (cfs) 0.7 0.3 5.2 Major Total Design Peak Flow, Q (cfs) 3.2 1.3 24.3 Minor Flow Bypassed Downstream, Qb (cfs)0.0 0.0 N/A Major Flow Bypassed Downstream, Qb (cfs)0.0 0.0 N/A INLET MANAGEMENT C03 MHFD-Inlet, Version 5.01 (April 2021) Worksheet Protected INLET NAME Site Type (Urban or Rural) Inlet Application (Street or Area) Hydraulic Condition Inlet Type USER-DEFINED INPUT User-Defined Design Flows Minor QKnown (cfs) Major QKnown (cfs) Bypass (Carry-Over) Flow from Upstream Receive Bypass Flow from: Minor Bypass Flow Received, Qb (cfs) Major Bypass Flow Received, Qb (cfs) Watershed Characteristics Subcatchment Area (acres) Percent Impervious NRCS Soil Type Watershed Profile Overland Slope (ft/ft) Overland Length (ft) Channel Slope (ft/ft) Channel Length (ft) Minor Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) Major Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) CALCULATED OUTPUT Minor Total Design Peak Flow, Q (cfs) Major Total Design Peak Flow, Q (cfs) Minor Flow Bypassed Downstream, Qb (cfs) Major Flow Bypassed Downstream, Qb (cfs) INLET MANAGEMENT Inlet F Inlet A Inlet B URBAN URBAN URBAN STREET STREET STREET In Sump In Sump In Sump CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening 0.4 0.6 0.5 1.9 2.4 2.2 No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0.6 0.5 1.9 2.4 2.2 N/A N/A N/A N/A N/A N/A C04 MHFD-Inlet, Version 5.01 (April 2021) Worksheet Protected INLET NAME Site Type (Urban or Rural) Inlet Application (Street or Area) Hydraulic Condition Inlet Type USER-DEFINED INPUT User-Defined Design Flows Minor QKnown (cfs) Major QKnown (cfs) Bypass (Carry-Over) Flow from Upstream Receive Bypass Flow from: Minor Bypass Flow Received, Qb (cfs) Major Bypass Flow Received, Qb (cfs) Watershed Characteristics Subcatchment Area (acres) Percent Impervious NRCS Soil Type Watershed Profile Overland Slope (ft/ft) Overland Length (ft) Channel Slope (ft/ft) Channel Length (ft) Minor Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) Major Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) CALCULATED OUTPUT Minor Total Design Peak Flow, Q (cfs) Major Total Design Peak Flow, Q (cfs) Minor Flow Bypassed Downstream, Qb (cfs) Major Flow Bypassed Downstream, Qb (cfs) INLET MANAGEMENT Inlet C1 Inlet C2 Inlet C3 URBAN URBAN URBAN STREET STREET STREET On Grade On Grade On Grade CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening 5.3 2.4 2.0 24.3 10.4 8.8 No Bypass Flow Received No Bypass Flow Received User-Defined 0.0 0.0 0.0 0.0 0.0 3.3 5.3 2.4 2.0 24.3 10.4 12.1 0.0 0.0 0.0 7.9 2.7 4.2 C05 MHFD-Inlet, Version 5.01 (April 2021) Worksheet Protected INLET NAME Site Type (Urban or Rural) Inlet Application (Street or Area) Hydraulic Condition Inlet Type USER-DEFINED INPUT User-Defined Design Flows Minor QKnown (cfs) Major QKnown (cfs) Bypass (Carry-Over) Flow from Upstream Receive Bypass Flow from: Minor Bypass Flow Received, Qb (cfs) Major Bypass Flow Received, Qb (cfs) Watershed Characteristics Subcatchment Area (acres) Percent Impervious NRCS Soil Type Watershed Profile Overland Slope (ft/ft) Overland Length (ft) Channel Slope (ft/ft) Channel Length (ft) Minor Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) Major Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) CALCULATED OUTPUT Minor Total Design Peak Flow, Q (cfs) Major Total Design Peak Flow, Q (cfs) Minor Flow Bypassed Downstream, Qb (cfs) Major Flow Bypassed Downstream, Qb (cfs) INLET MANAGEMENT Inlet C6 Inlet D Inlet C5 URBAN URBAN URBAN STREET STREET STREET On Grade In Sump On Grade CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening 0.7 0.6 2.3 3.2 2.6 10.7 No Bypass Flow Received No Bypass Flow Received User-Defined 0.0 0.0 0.0 0.0 0.0 0.0 0.7 0.6 2.3 3.2 2.6 10.7 0.0 N/A 0.0 0.0 N/A 3.3 C06 MHFD-Inlet, Version 5.01 (April 2021) Worksheet Protected INLET NAME Site Type (Urban or Rural) Inlet Application (Street or Area) Hydraulic Condition Inlet Type USER-DEFINED INPUT User-Defined Design Flows Minor QKnown (cfs) Major QKnown (cfs) Bypass (Carry-Over) Flow from Upstream Receive Bypass Flow from: Minor Bypass Flow Received, Qb (cfs) Major Bypass Flow Received, Qb (cfs) Watershed Characteristics Subcatchment Area (acres) Percent Impervious NRCS Soil Type Watershed Profile Overland Slope (ft/ft) Overland Length (ft) Channel Slope (ft/ft) Channel Length (ft) Minor Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) Major Storm Rainfall Input Design Storm Return Period, Tr (years) One-Hour Precipitation, P1 (inches) CALCULATED OUTPUT Minor Total Design Peak Flow, Q (cfs) Major Total Design Peak Flow, Q (cfs) Minor Flow Bypassed Downstream, Qb (cfs) Major Flow Bypassed Downstream, Qb (cfs) INLET MANAGEMENT Inlet C4 User-Defined URBAN STREET In Sump CDOT Type R Curb Opening 4.7 20.7 User-Defined 0.0 14.8 4.7 35.5 N/A N/A C07 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.022 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no) MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow =11.9 11.9 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet G 1 C08 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 2 2 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 0.7 3.2 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 0.0 cfs Capture Percentage = Qa/Qo =C% = 100 100 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C09 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.022 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no). MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow =11.9 11.9 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet H 1 C10 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 1 1 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 0.3 1.3 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 0.0 cfs Capture Percentage = Qa/Qo =C% = 100 98 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C11 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Check boxes are not applicable in SUMP conditions MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet E 1 C12 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening)No =2 2 Water Depth at Flowline (outside of local depression)Ponding Depth =5.0 11.4 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) =N/A N/A feet Width of a Unit Grate Wo =N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67 Low Head Performance Reduction (Calculated)MINOR MAJOR Depth for Grate Midwidth dGrate =N/A N/A ft Depth for Curb Opening Weir Equation dCurb =0.25 0.78 ft Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.47 1.00 Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.87 1.00 Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition)Qa =6.3 24.9 cfs Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =5.2 24.3 cfs CDOT Type R Curb Opening INLET IN A SUMP OR SAG LOCATION MHFD-Inlet, Version 5.01 (April 2021) H-VertH-Curb W Lo (C) Lo (G) Wo WP CDOT Type R Curb Opening Override Depths 1 C13 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Check boxes are not applicable in SUMP conditions MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet F 1 C14 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening)No =1 1 Water Depth at Flowline (outside of local depression)Ponding Depth =5.0 11.4 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) =N/A N/A feet Width of a Unit Grate Wo =N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67 Low Head Performance Reduction (Calculated)MINOR MAJOR Depth for Grate Midwidth dGrate =N/A N/A ft Depth for Curb Opening Weir Equation dCurb =0.25 0.78 ft Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.64 1.00 Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00 Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition)Qa =3.5 12.0 cfs Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.4 1.9 cfs CDOT Type R Curb Opening INLET IN A SUMP OR SAG LOCATION MHFD-Inlet, Version 5.01 (April 2021) H-VertH-Curb W Lo (C) Lo (G) Wo WP CDOT Type R Curb Opening Override Depths 1 C15 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Check boxes are not applicable in SUMP conditions MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet A 1 C16 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening)No =1 1 Water Depth at Flowline (outside of local depression)Ponding Depth =5.0 11.4 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) =N/A N/A feet Width of a Unit Grate Wo =N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67 Low Head Performance Reduction (Calculated)MINOR MAJOR Depth for Grate Midwidth dGrate =N/A N/A ft Depth for Curb Opening Weir Equation dCurb =0.25 0.78 ft Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.64 1.00 Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00 Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition)Qa =3.5 12.0 cfs Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.6 2.4 cfs CDOT Type R Curb Opening INLET IN A SUMP OR SAG LOCATION MHFD-Inlet, Version 5.01 (April 2021) H-VertH-Curb W Lo (C) Lo (G) Wo WP CDOT Type R Curb Opening Override Depths 1 C17 Project: Inlet ID: DI NEA Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Check boxes are not applicable in SUMP conditions MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet B 1 C18 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening)No =1 1 Water Depth at Flowline (outside of local depression)Ponding Depth =5.0 11.4 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) =N/A N/A feet Width of a Unit Grate Wo =N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67 Low Head Performance Reduction (Calculated)MINOR MAJOR Depth for Grate Midwidth dGrate =N/A N/A ft Depth for Curb Opening Weir Equation dCurb =0.25 0.78 ft Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.64 1.00 Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00 Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition)Qa =3.5 12.0 cfs Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.5 2.2 cfs CDOT Type R Curb Opening INLET IN A SUMP OR SAG LOCATION MHFD-Inlet, Version 5.01 (April 2021) H-VertH-Curb W Lo (C) Lo (G) Wo WP CDOT Type R Curb Opening Override Depths 1 C19 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =1.410 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no) MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =5.5 30.1 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet C1 1 C20 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 3 3 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 5.3 16.4 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 7.9 cfs Capture Percentage = Qa/Qo =C% = 100 67 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C21 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =1.410 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no) MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =5.5 30.1 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet C2 1 C22 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 2 2 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 2.4 7.7 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 2.7 cfs Capture Percentage = Qa/Qo =C% = 100 74 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C23 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.020 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no) MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =10.5 108.1 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet C3 1 C24 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 2 2 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 2.0 7.9 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 4.2 cfs Capture Percentage = Qa/Qo =C% = 100 66 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C25 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.006 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no) MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =5.9 72.7 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet C6 1 C26 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 2 2 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 0.7 3.2 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 0.0 cfs Capture Percentage = Qa/Qo =C% = 100 100 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C27 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =21.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =21.0 21.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 11.4 inches Check boxes are not applicable in SUMP conditions MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet D 1 C28 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening)No =1 1 Water Depth at Flowline (outside of local depression)Ponding Depth =5.0 11.4 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) =N/A N/A feet Width of a Unit Grate Wo =N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67 Low Head Performance Reduction (Calculated)MINOR MAJOR Depth for Grate Midwidth dGrate =N/A N/A ft Depth for Curb Opening Weir Equation dCurb =0.25 0.78 ft Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.64 1.00 Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00 Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition)Qa =3.5 12.0 cfs Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.6 2.6 cfs CDOT Type R Curb Opening INLET IN A SUMP OR SAG LOCATION MHFD-Inlet, Version 5.01 (April 2021) H-VertH-Curb W Lo (C) Lo (G) Wo WP CDOT Type R Curb Opening Override Depths 1 C29 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =15.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.006 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =5.0 11.4 inches Allow Flow Depth at Street Crown (check box for yes, leave blank for no) MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =5.9 72.7 cfs Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management' MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet C5 1 C30 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches Total Number of Units in the Inlet (Grate or Curb Opening)No = 2 2 Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo =N/A N/A ft Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10 Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR Total Inlet Interception Capacity Q = 2.3 7.4 cfs Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 3.3 cfs Capture Percentage = Qa/Qo =C% = 100 69 % INLET ON A CONTINUOUS GRADE MHFD-Inlet, Version 5.01 (April 2021) CDOT Type R Curb OpeningCDOT Type R Curb Opening 1 C31 Project: Inlet ID: Gutter Geometry: Maximum Allowable Width for Spread Behind Curb TBACK =22.5 ft Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.020 Height of Curb at Gutter Flow Line HCURB =6.00 inches Distance from Curb Face to Street Crown TCROWN =21.0 ft Gutter Width W =2.00 ft Street Transverse Slope SX =0.020 ft/ft Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016 Minor Storm Major Storm Max. Allowable Spread for Minor & Major Storm TMAX =21.0 21.0 ft Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 11.4 inches Check boxes are not applicable in SUMP conditions MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs MHFD-Inlet, Version 5.01 (April 2021) ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm) (Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread) Hyline Residences Inlet C4 1 C32 Design Information (Input)MINOR MAJOR Type of Inlet Type = Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches Number of Unit Inlets (Grate or Curb Opening)No =3 3 Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 11.4 inches Grate Information MINOR MAJOR Length of a Unit Grate Lo (G) =N/A N/A feet Width of a Unit Grate Wo =N/A N/A feet Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A Curb Opening Information MINOR MAJOR Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10 Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60 Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67 Low Head Performance Reduction (Calculated)MINOR MAJOR Depth for Grate Midwidth dGrate =N/A N/A ft Depth for Curb Opening Weir Equation dCurb =0.33 0.78 ft Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.57 1.00 Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.79 1.00 Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A MINOR MAJOR Total Inlet Interception Capacity (assumes clogged condition)Qa =13.5 38.1 cfs Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =4.7 35.5 cfs CDOT Type R Curb Opening INLET IN A SUMP OR SAG LOCATION MHFD-Inlet, Version 5.01 (April 2021) H-VertH-Curb W Lo (C) Lo (G) Wo WP CDOT Type R Curb Opening Override Depths 1 C33 C34 C35 Conduit FlexTable: Combined Pipe/Node Report Energy Grade Line (Out) (ft) Energy Grade Line (In) (ft) Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) Velocity (ft/s) Flow (cfs) Invert (Stop) (ft) Stop NodeInvert (Start) (ft) Start NodeMaterialDiameter (in) Label 5,077.045,077.175,076.715,076.904.585.305,076.14DPD5,076.0030IN FES-1Concrete30.0P1 5,077.195,077.615,077.065,077.355.724.705,076.64DPC45,076.14DPDConcrete30.0P2 5,077.005,077.445,076.715,077.184.335.005,076.44MH-65,076.0030IN FES-2Concrete30.0P3 5,077.955,078.155,077.385,077.626.0621.405,076.20MH-15,076.0042IN FES-3Concrete42.0P4 5,078.315,079.735,078.045,079.207.6721.405,077.78MH-25,076.20MH-1Concrete42.0P5 5,079.775,084.475,079.735,084.158.828.105,083.25MH-35,077.78MH-2Concrete36.0P6 5,084.535,085.175,084.345,084.856.348.105,083.95MH-45,083.25MH-3Concrete36.0P7 5,085.275,086.395,085.115,086.075.308.105,085.17MH-55,083.95MH-4Concrete36.0P8 5,086.455,086.685,086.295,086.3712.107.605,085.50DPA5,085.17MH-5Concrete36.0P9 5,086.745,086.805,086.525,086.484.957.005,085.60DPOS25,085.50DPAConcrete30.0P10 5,086.295,086.305,086.295,086.293.070.505,085.50DPB5,085.17MH-5Concrete24.0P11 5,077.415,084.135,077.345,083.916.063.005,083.31MH-75,076.44MH-6Concrete24.0P13 5,084.145,084.315,084.075,084.134.622.305,083.60DPC55,083.31MH-7Concrete24.0P14 5,084.075,084.085,084.075,084.055.940.705,083.60DPC65,083.31MH-7Concrete24.0P15 5,077.375,077.395,077.345,077.343.242.005,076.56DPC35,076.44MH-6Concrete24.0P16 5,079.775,080.205,079.735,079.888.177.705,079.01MH-85,077.78MH-2Concrete36.0P17 5,080.215,080.255,080.105,080.084.775.305,079.17DPC15,079.01MH-8Concrete30.0P18 5,080.135,080.135,080.105,080.104.022.405,079.06DPC25,079.01MH-8Concrete30.0P19 5,079.755,079.785,079.735,079.734.555.605,078.43MH-95,077.78MH-2Concrete36.0P20 5,079.815,079.825,079.775,079.764.445.205,078.57DPE5,078.43MH-9Concrete36.0P21 5,079.775,079.775,079.775,079.763.470.405,078.57DPF5,078.43MH-9Concrete24.0P22 5,075.515,075.695,075.355,075.553.161.005,075.18DPH5,075.0018IN FES-4Concrete18.0P23 5,075.665,075.765,075.625,075.662.580.705,075.34DPG5,075.18DPHConcrete18.0P24 5,076.005,076.005,076.005,076.000.000.005,074.00OUTLET STRUCTURE5,073.5015IN FES-5Concrete15.0P25 Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203-755-16661/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C36 FlexTable: Catch Basin Table Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) Elevation (Invert) (ft) Elevation (Rim) (ft) Flow (Additional Carryover) (cfs) Elevation (Ground) (ft) Label 5,076.905,077.065,076.145,081.590.605,081.09DPD 5,077.355,077.355,076.645,081.594.705,081.09DPC4 5,079.765,079.765,078.575,083.855.205,083.35DPE 5,079.765,079.765,078.575,083.860.405,083.36DPF 5,086.375,086.525,085.505,090.220.605,089.72DPA 5,086.295,086.295,085.505,090.240.505,089.74DPB 5,080.105,080.105,079.065,084.952.405,084.45DPC2 5,080.085,080.085,079.175,084.945.305,084.44DPC1 5,086.485,086.485,085.605,090.007.005,092.00DPOS2 5,084.135,084.135,083.605,089.102.305,088.60DPC5 5,084.055,084.055,083.605,089.080.705,088.58DPC6 5,077.345,077.345,076.565,082.172.005,081.67DPC3 5,075.555,075.625,075.185,080.810.305,080.31DPH 5,075.665,075.665,075.345,080.840.705,080.34DPG 5,076.005,076.005,074.005,077.000.005,077.00OUTLET STRUCTURE Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C37 FlexTable: Manhole Table Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) Elevation (Invert in 1) (ft) Elevation (Rim) (ft) Structure TypeDiameter (in) Label 5,077.625,078.045,076.205,081.61Circular Structure60.0MH-1 5,079.205,079.735,077.785,084.47Circular Structure60.0MH-2 5,079.735,079.775,078.435,083.57Circular Structure60.0MH-9 5,084.155,084.345,083.255,092.33Circular Structure60.0MH-3 5,084.855,085.115,083.955,093.75Circular Structure60.0MH-4 5,086.075,086.295,085.175,089.90Circular Structure60.0MH-5 5,079.885,080.105,079.015,084.67Circular Structure60.0MH-8 5,077.185,077.345,076.445,081.78Circular Structure60.0MH-6 5,083.915,084.075,083.315,088.81Circular Structure60.0MH-7 Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C38 FlexTable: Outfall Table Flow (Total Out) (cfs) Hydraulic Grade (ft) Boundary Condition TypeElevation (Invert) (ft) Set Rim to Ground Elevation? Elevation (Ground) (ft) LabelID 5.305,076.71Free Outfall5,076.00True5,079.5030IN FES-131 5.005,076.71Free Outfall5,076.00True5,079.5030IN FES-279 1.005,075.35Free Outfall5,075.00True5,080.0018IN FES-497 0.005,076.00User Defined Tailwater5,073.50True5,078.0015IN FES-598 21.405,077.38Free Outfall5,076.00True5,079.5042IN FES-3110 Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C39 Profile Report Engineering Profile - FES1 TO DPC4 (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 Station (ft)Elevation (ft)DPC4 Rim: 5,081.59 ft Invert: 5,076.64 ft DPD Rim: 5,081.59 ft Invert: 5,076.14 ft30IN FES-1 Rim: 5,079.50 ft Invert: 5,076.00 ft P 2 : 4 6 .2 f t @ -0 .0 1 1 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e P 1 : 2 6 .5 f t @ -0 .0 0 5 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C40 Profile Report Engineering Profile - FES2 TO DPC3 (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 1+50 Station (ft)Elevation (ft)MH-6 Rim: 5,081.78 ft Invert: 5,076.44 ft DPC3 Rim: 5,082.17 ft Invert: 5,076.56 ft 30IN FES-2 Rim: 5,079.50 ft Invert: 5,076.00 ft P 3 : 9 3.6 ft @ -0.0 0 5 f t/ft C i r c l e - 3 0 .0 i n C o n c r e t e P1 6 : 2 9 .3 f t @ -0 .0 0 4 f t/f t C i r c l e - 2 4 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C41 Profile Report Engineering Profile - FES2 TO DPC5 (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 5,090.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 Station (ft)Elevation (ft)MH-7 Rim: 5,088.81 ft Invert: 5,083.31 ft MH-6 Rim: 5,081.78 ft Invert: 5,076.44 ft DPC5 Rim: 5,089.10 ft Invert: 5,083.60 ft 30IN FES-2 Rim: 5,079.50 ft Invert: 5,076.00 ft P3: 93.6 ft @ -0.005 ft/ft C ircle - 30.0 in Concr ete P 1 4 : 2 9 .2 f t @ -0 .0 1 0 f t /f t C i r c l e - 2 4 .0 i n C o n c r e t e P 1 3 : 4 0 0 .1 f t @ -0 .0 1 7 f t /f t C i r c l e - 2 4 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C42 Profile Report Engineering Profile - FES3 TO DPC1 (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 Station (ft)Elevation (ft)MH-8 Rim: 5,084.67 ft Invert: 5,079.01 ft MH-2 Rim: 5,084.47 ft Invert: 5,077.78 ft MH-1 Rim: 5,081.61 ft Invert: 5,076.20 ft DPC1 Rim: 5,084.94 ft Invert: 5,079.17 ft 42IN FES-3 Rim: 5,079.50 ft Invert: 5,076.00 ft P 1 8 : 2 7 .2 f t @ -0 .0 0 6 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e P 1 7 : 5 8 .8 f t @ -0 .0 2 1 f t /f t C i r c l e - 3 6 .0 i n C o n c r e t e P5 : 1 9 7 .0 f t @ -0 .0 0 8 f t /f t C i r c l e - 4 2 .0 i n C o n c r e t e P4: 47.7 f t @ -0.004 ft/f t C ircl e - 42.0 in C oncr ete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C43 Profile Report Engineering Profile - DPC1 TO DPC2 (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 Station (ft)Elevation (ft)MH-8 Rim: 5,084.67 ft Invert: 5,079.01 ftDPC2 Rim: 5,084.95 ft Invert: 5,079.06 ft DPC1 Rim: 5,084.94 ft Invert: 5,079.17 ft P19: 7.2 ft @ -0.007 ft/ft Circle - 30.0 in Concrete P 1 8 : 2 7 .2 f t @ -0 .0 0 6 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C44 Profile Report Engineering Profile - FES3 TO DPE (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 Station (ft)Elevation (ft)MH-9 Rim: 5,083.57 ft Invert: 5,078.43 ft MH-2 Rim: 5,084.47 ft Invert: 5,077.78 ft MH-1 Rim: 5,081.61 ft Invert: 5,076.20 ft DPE Rim: 5,083.85 ft Invert: 5,078.57 ft 42IN FES-3 Rim: 5,079.50 ft Invert: 5,076.00 ft P 2 1: 27 .2 ft @ -0.0 05 f t /f t C i rcl e - 3 6.0 in C o n c re te P20 : 125.0 ft @ -0.00 5 ft /ft Ci rcl e - 36.0 in C oncre teP5: 1 9 7 .0 f t @ -0 .0 0 8 f t /f t C i r c l e - 4 2 .0 i n C o n c r e t e P4: 47.7 ft @ -0.004 ft/ft Cir cle - 42.0 in C oncre te Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C45 Profile Report Engineering Profile - DPE TO DPF (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 Station (ft)Elevation (ft)MH-9 Rim: 5,083.57 ft Invert: 5,078.43 ft DPF Rim: 5,083.86 ft Invert: 5,078.57 ft DPE Rim: 5,083.85 ft Invert: 5,078.57 ft P22: 7.2 ft @ -0.020 ft/ft Circle - 24.0 in Concrete P 2 1 : 2 7 .2 f t @ -0 .0 0 5 f t /f t C i r c l e - 3 6 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C46 Profile Report Engineering Profile - DPC5 TO DPC6 (221221 STORM 2YR.stsw) 5,080.00 5,085.00 5,090.00 -0+50 0+00 0+50 Station (ft)Elevation (ft)MH-7 Rim: 5,088.81 ft Invert: 5,083.31 ft DPC6 Rim: 5,089.08 ft Invert: 5,083.60 ft DPC5 Rim: 5,089.10 ft Invert: 5,083.60 ft P 1 4 : 2 9 .2 f t @ -0 .0 1 0 f t /f t C i r c l e - 2 4 .0 i n C o n c r e t e P15: 5.2 ft @ -0.056 ft/ft Circle - 24.0 in Concrete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C47 Profile Report Engineering Profile - FES4 TO DPG (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 Station (ft)Elevation (ft)DPG Rim: 5,080.84 ft Invert: 5,075.34 ft DPH Rim: 5,080.81 ft Invert: 5,075.18 ft 18IN FES-4 Rim: 5,080.00 ft Invert: 5,075.00 ft P 2 4 : 3 4 .3 f t @ -0 .0 0 5 f t /f t C i r c l e - 1 8 .0 i n C o n c r e t e P 2 3 : 2 9 .2 f t @ -0 .0 0 6 f t /f t C i r cl e - 1 8 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C48 Profile Report Engineering Profile - FES3 TO DPOS2 (221221 STORM 2YR.stsw) 5,075.00 5,080.00 5,085.00 5,090.00 5,095.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 Station (ft)Elevation (ft)MH-5 Rim: 5,089.90 ft Invert: 5,085.17 ft MH-4 Rim: 5,093.75 ft Invert: 5,083.95 ft MH-3 Rim: 5,092.33 ft Invert: 5,083.25 ft MH-2 Rim: 5,084.47 ft Invert: 5,077.78 ft MH-1 Rim: 5,081.61 ft Invert: 5,076.20 ft DPOS2 Rim: 5,090.00 ft Invert: 5,085.60 ft DPA Rim: 5,090.22 ft Invert: 5,085.50 ft 42IN FES-3 Rim: 5,079.50 ft Invert: 5,076.00 ft P10: 19.1 ft @ -0.005 ft/ft Circ le - 30.0 in Conc rete P9: 5.1 ft @ -0.065 ft/ft Circle - 36.0 in Concrete P8: 206.3 f t @ -0.006 ft/ft Circ le - 36.0 in Concr eteP7: 71 .3 f t @ -0 .0 1 0 ft /f t C irc le - 3 6 .0 i n C o n cr e t e P 6 : 2 1 9 .3 f t @ -0 .0 2 5 f t /f t C i r c l e - 3 6 .0 i n C o n c r e t e P5 : 19 7 .0 f t @ -0 .008 ft/ft Circle - 42 .0 in C o ncrete P4: 47.7 ft @ -0.004 ft/ft Circle - 42.0 in Concrete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 2YR.stsw C49 Conduit FlexTable: Combined Pipe/Node Report Energy Grade Line (Out) (ft) Energy Grade Line (In) (ft) Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) Velocity (ft/s) Flow (cfs) Invert (Stop) (ft) Stop NodeInvert (Start) (ft) Start NodeMaterialDiameter (in) Label 5,080.145,080.375,079.205,079.437.7638.105,076.14DPD5,076.0030IN FES-1Concrete30.0P1 5,080.805,081.155,079.995,080.347.2335.505,076.64DPC45,076.14DPDConcrete30.0P2 5,079.425,079.615,079.205,079.393.7718.505,076.44MH-65,076.0030IN FES-2Concrete30.0P3 5,080.545,080.845,079.205,079.588.9085.605,076.20MH-15,076.0042IN FES-3Concrete42.0P4 5,081.825,083.245,080.595,082.018.9085.605,077.78MH-25,076.20MH-1Concrete42.0P5 5,083.635,086.025,083.245,085.1813.4235.305,083.25MH-35,077.78MH-2Concrete36.0P6 5,086.205,086.725,085.685,085.889.5035.305,083.95MH-45,083.25MH-3Concrete36.0P7 5,087.015,087.945,086.555,087.107.8235.305,085.17MH-55,083.95MH-4Concrete36.0P8 5,088.115,088.165,087.695,087.3718.6133.105,085.50DPA5,085.17MH-5Concrete36.0P9 5,088.445,088.535,087.775,087.856.8730.705,085.60DPOS25,085.50DPAConcrete30.0P10 5,087.695,087.705,087.695,087.690.702.205,085.50DPB5,085.17MH-5Concrete24.0P11 5,079.705,084.965,079.525,084.488.6510.605,083.31MH-75,076.44MH-6Concrete24.0P13 5,084.955,085.005,084.815,084.766.437.405,083.60DPC55,083.31MH-7Concrete24.0P14 5,084.845,084.845,084.815,084.809.373.205,083.60DPC65,083.31MH-7Concrete24.0P15 5,079.625,079.665,079.525,079.562.517.905,076.56DPC35,076.44MH-6Concrete24.0P16 5,083.425,083.505,083.245,083.323.4124.105,079.01MH-85,077.78MH-2Concrete36.0P17 5,083.625,083.665,083.455,083.493.3416.405,079.17DPC15,079.01MH-8Concrete30.0P18 5,083.485,083.495,083.455,083.451.577.705,079.06DPC25,079.01MH-8Concrete30.0P19 5,083.465,083.655,083.245,083.443.7126.205,078.43MH-95,077.78MH-2Concrete36.0P20 5,083.755,083.795,083.575,083.613.4424.305,078.57DPE5,078.43MH-9Concrete36.0P21 5,083.585,083.585,083.575,083.570.601.905,078.57DPF5,078.43MH-9Concrete24.0P22 5,079.305,079.355,079.205,079.252.554.505,075.18DPH5,075.0018IN FES-4Concrete18.0P23 5,079.355,079.395,079.305,079.341.813.205,075.34DPG5,075.18DPHConcrete18.0P24 5,076.465,076.995,076.005,076.535.466.705,074.00OUTLET STRUCTURE5,073.5015IN FES-5Concrete15.0P25 Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203-755-16661/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C50 FlexTable: Catch Basin Table Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) Elevation (Invert) (ft) Elevation (Rim) (ft) Flow (Additional Carryover) (cfs) Elevation (Ground) (ft) Label 5,079.435,079.995,076.145,081.592.605,081.09DPD 5,080.345,080.345,076.645,081.5935.505,081.09DPC4 5,083.615,083.615,078.575,083.8524.305,083.35DPE 5,083.575,083.575,078.575,083.861.905,083.36DPF 5,087.375,087.775,085.505,090.222.405,089.72DPA 5,087.695,087.695,085.505,090.242.205,089.74DPB 5,083.455,083.455,079.065,084.957.705,084.45DPC2 5,083.495,083.495,079.175,084.9416.405,084.44DPC1 5,087.855,087.855,085.605,090.0030.705,092.00DPOS2 5,084.765,084.765,083.605,089.107.405,088.60DPC5 5,084.805,084.805,083.605,089.083.205,088.58DPC6 5,079.565,079.565,076.565,082.177.905,081.67DPC3 5,079.255,079.305,075.185,080.811.305,080.31DPH 5,079.345,079.345,075.345,080.843.205,080.34DPG 5,076.535,076.535,074.005,077.006.705,077.00OUTLET STRUCTURE Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C51 FlexTable: Manhole Table Hydraulic Grade Line (Out) (ft) Hydraulic Grade Line (In) (ft) Elevation (Invert in 1) (ft) Elevation (Rim) (ft) Structure TypeDiameter (in) Label 5,079.585,080.595,076.205,081.61Circular Structure60.0MH-1 5,082.015,083.245,077.785,084.47Circular Structure60.0MH-2 5,083.445,083.595,078.435,083.57Circular Structure60.0MH-9 5,085.185,085.685,083.255,092.33Circular Structure60.0MH-3 5,085.885,086.555,083.955,093.75Circular Structure60.0MH-4 5,087.105,087.695,085.175,089.90Circular Structure60.0MH-5 5,083.325,083.455,079.015,084.67Circular Structure60.0MH-8 5,079.395,079.525,076.445,081.78Circular Structure60.0MH-6 5,084.485,084.815,083.315,088.81Circular Structure60.0MH-7 Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C52 FlexTable: Outfall Table Flow (Total Out) (cfs) Hydraulic Grade (ft) Boundary Condition TypeElevation (Invert) (ft) Set Rim to Ground Elevation? Elevation (Ground) (ft) LabelID 38.105,079.20User Defined Tailwater5,076.00True5,079.5030IN FES-131 18.505,079.20User Defined Tailwater5,076.00True5,079.5030IN FES-279 4.505,079.20User Defined Tailwater5,075.00True5,080.0018IN FES-497 6.705,076.00User Defined Tailwater5,073.50True5,078.0015IN FES-598 85.605,079.20User Defined Tailwater5,076.00True5,079.5042IN FES-3110 Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C53 Profile Report Engineering Profile - FES1 TO DPC4 (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 Station (ft)Elevation (ft)DPC4 Rim: 5,081.59 ft Invert: 5,076.64 ft DPD Rim: 5,081.59 ft Invert: 5,076.14 ft30IN FES-1 Rim: 5,079.50 ft Invert: 5,076.00 ft P 2 : 4 6 .2 f t @ -0 .0 1 1 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e P 1 : 2 6 .5 f t @ -0 .0 0 5 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C54 Profile Report Engineering Profile - FES2 TO DPC3 (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 1+50 Station (ft)Elevation (ft)MH-6 Rim: 5,081.78 ft Invert: 5,076.44 ft DPC3 Rim: 5,082.17 ft Invert: 5,076.56 ft 30IN FES-2 Rim: 5,079.50 ft Invert: 5,076.00 ft P 3 : 9 3 .6 ft @ -0 .0 0 5 f t/f t C i rcl e - 3 0 .0 i n C o n cr e te P 1 6 : 2 9 .3 ft @ -0 .0 0 4 ft /f t C i r c l e - 2 4 .0 i n C o n c r e te Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C55 Profile Report Engineering Profile - FES2 TO DPC5 (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 5,090.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 Station (ft)Elevation (ft)MH-7 Rim: 5,088.81 ft Invert: 5,083.31 ft MH-6 Rim: 5,081.78 ft Invert: 5,076.44 ft DPC5 Rim: 5,089.10 ft Invert: 5,083.60 ft 30IN FES-2 Rim: 5,079.50 ft Invert: 5,076.00 ft P3: 93.6 ft @ -0.005 ft/ft C ircle - 30.0 in Concr ete P 1 4 : 2 9 .2 f t @ -0 .0 1 0 f t /f t C i r c l e - 2 4 .0 i n C o n c r e t e P 1 3 : 4 0 0 .1 f t @ -0 .0 1 7 f t /f t C i r c l e - 2 4 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C56 Profile Report Engineering Profile - FES3 TO DPC1 (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 Station (ft)Elevation (ft)MH-8 Rim: 5,084.67 ft Invert: 5,079.01 ft MH-2 Rim: 5,084.47 ft Invert: 5,077.78 ft MH-1 Rim: 5,081.61 ft Invert: 5,076.20 ft DPC1 Rim: 5,084.94 ft Invert: 5,079.17 ft 42IN FES-3 Rim: 5,079.50 ft Invert: 5,076.00 ft P 1 8 : 2 7 .2 f t @ -0 .0 0 6 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e P 1 7 : 5 8 .8 f t @ -0 .0 2 1 f t /f t C i r c l e - 3 6 .0 i n C o n c r e t e P 5 : 1 9 7 .0 ft @ -0 .0 0 8 f t /f t C i r c l e - 4 2 .0 i n C o n c r e t e P 4: 47.6 ft @ -0.0 04 f t/ft Ci r cle - 42.0 in Co ncrete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C57 Profile Report Engineering Profile - DPC1 TO DPC2 (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 Station (ft)Elevation (ft)MH-8 Rim: 5,084.67 ft Invert: 5,079.01 ftDPC2 Rim: 5,084.95 ft Invert: 5,079.06 ft DPC1 Rim: 5,084.94 ft Invert: 5,079.17 ft P19: 7.2 ft @ -0.007 ft/ft Circle - 30.0 in Concrete P 1 8 : 2 7 .2 f t @ -0 .0 0 6 f t /f t C i r c l e - 3 0 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C58 Profile Report Engineering Profile - FES3 TO DPE (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 Station (ft)Elevation (ft)MH-9 Rim: 5,083.57 ft Invert: 5,078.43 ft MH-2 Rim: 5,084.47 ft Invert: 5,077.78 ft MH-1 Rim: 5,081.61 ft Invert: 5,076.20 ft DPE Rim: 5,083.85 ft Invert: 5,078.57 ft 42IN FES-3 Rim: 5,079.50 ft Invert: 5,076.00 ft P21 : 27 .2 f t @ -0 .0 0 5 f t/f t C i r c l e - 3 6 .0 i n C o n c r e t e P 2 0: 125 .0 f t @ -0.005 ft/ft Ci rc l e - 36 .0 i n Conc ret eP5: 1 9 7 .0 f t @ -0 .0 0 8 f t /ft C i r c l e - 4 2 .0 i n C o n c re t e P4: 4 7.6 ft @ -0.00 4 ft /ft Circ le - 42.0 in Con crete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C59 Profile Report Engineering Profile - DPE TO DPF (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 Station (ft)Elevation (ft)MH-9 Rim: 5,083.57 ft Invert: 5,078.43 ft DPF Rim: 5,083.86 ft Invert: 5,078.57 ft DPE Rim: 5,083.85 ft Invert: 5,078.57 ft P22: 7.2 ft @ -0.020 ft/ft Circle - 24.0 in Concrete P 2 1 : 2 7 .2 f t @ -0 .0 0 5 f t /f t C i r c l e - 3 6 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C60 Profile Report Engineering Profile - DPC5 TO DPC6 (221221 STORM 100YR.stsw) 5,080.00 5,085.00 5,090.00 -0+50 0+00 0+50 Station (ft)Elevation (ft)MH-7 Rim: 5,088.81 ft Invert: 5,083.31 ft DPC6 Rim: 5,089.08 ft Invert: 5,083.60 ft DPC5 Rim: 5,089.10 ft Invert: 5,083.60 ft P 1 4 : 2 9 .2 ft @ -0 .0 1 0 f t /f t C i r c l e - 2 4 .0 i n C o n c r e t e P15: 5.2 ft @ -0.056 ft/ft Circle - 24.0 in Concrete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C61 Profile Report Engineering Profile - FES4 TO DPG (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 -0+50 0+00 0+50 1+00 Station (ft)Elevation (ft)DPG Rim: 5,080.84 ft Invert: 5,075.34 ft DPH Rim: 5,080.81 ft Invert: 5,075.18 ft 18IN FES-4 Rim: 5,080.00 ft Invert: 5,075.00 ft P 2 4 : 3 4 .3 f t @ -0 .0 0 5 f t /f t C i r c l e - 1 8 .0 i n C o n c r e t e P 2 3 : 2 9 .2 f t @ -0 .0 0 6 f t /f t C i r cl e - 1 8 .0 i n C o n c r e t e Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C62 Profile Report Engineering Profile - FES3 TO DPOS2 (221221 STORM 100YR.stsw) 5,075.00 5,080.00 5,085.00 5,090.00 5,095.00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 Station (ft)Elevation (ft)MH-5 Rim: 5,089.90 ft Invert: 5,085.17 ft MH-4 Rim: 5,093.75 ft Invert: 5,083.95 ft MH-3 Rim: 5,092.33 ft Invert: 5,083.25 ft MH-2 Rim: 5,084.47 ft Invert: 5,077.78 ft MH-1 Rim: 5,081.61 ft Invert: 5,076.20 ft DPOS2 Rim: 5,090.00 ft Invert: 5,085.60 ft DPA Rim: 5,090.22 ft Invert: 5,085.50 ft 42IN FES-3 Rim: 5,079.50 ft Invert: 5,076.00 ft P 10: 19.1 ft @ -0.005 ft/f t C ircle - 30.0 in Co ncrete P9: 5.1 ft @ -0.065 ft/ft Circle - 36.0 in Concrete P8: 206.3 ft @ -0.00 6 ft/ft Cir cle - 36.0 in Con creteP7: 7 1 .3 ft @ -0 .0 1 0 f t/ft C i r cl e - 3 6 .0 in C on c r e te P 6 : 2 1 9 .3 f t @ -0 .0 2 5 f t /f t C i r c l e - 3 6 .0 i n C o n c r e t e P5 : 19 7.0 ft @ -0.0 08 ft /f t Circle - 4 2.0 in Con cr ete P4: 47.6 ft @ -0.004 ft/ft Circle - 42.0 in Concrete Page 1 of 176 Watertown Road, Suite 2D Thomaston, CT 06787 USA +1-203- 755-1666 1/10/2023 StormCAD [10.03.04.53]Bentley Systems, Inc. Haestad Methods Solution Center221221 STORM 100YR.stsw C63 D APPENDIX D LOW IMPACT DEVELOPMENT, WATER QUALITY AND DETENTION POND INFORMATION SS SS SS SS SS FO FO FO FO FOFO FO FO G G G G G G FO FO FO FO FO W W W W W W W W W W G G G G G G G FOFOFOFOFOFOFOFOFOFOG G GG G GGE E E E E E E E E E EEE STEEEEEEEEEEXXXXXXXXXXXXX X X X X X X X X XXXXXXXXXXXXXXXXXXX X X X X X XXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXX X XXXX X X XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX X XXXXXXXXXXXXXXXXXXXXXXOHU OHU OHU OHU OHU OHU SS SS SS SS SS SS SS SS CTV G W W X X X X X X C.O. VAULT CABLE ELEC HY DVAULT ELEC ELEC W HY DWW S S S FO E G VAULT F.O. VAULT F.O. C C VAULT F.O. VAULT F.O. IMPERVIOUS EXHIBIT 1 XXX KM ES 22-100-449-00 12/19/224065 SAINT CLOUD DRIVE, SUITE 201LOVELAND, CO 80538PHONE: 970-834-6364www.wilsonco.comDRAWN BY: CHECKED BY: DATE:DESCRIPTIONDATEPROPERTY OWNERSEALPROJECT NAMEPROJECT NO: DESIGNED BY: SHEET NO: SHEET TITLE REV.BYXX% S U B MI T T A L NOT F O R CON S T R U C TI O N HULL ORCHARDSSUBDIVISIONSURFACE AREA (SF)% IMPERVIOUS IMPERVIOUS AREA (SF) ROOF 110000 100 110000 PAVED 217254 100 217254 GRAVEL 4478 40 1,791 LANDSCAPE 258503 2 5,170 TOTAL 590235 55 324629 1 2 3 4 5 6 A B C D E SURFACE AREA (SF)% IMPERVIOUS IMPERVIOUS AREA (SF) ROOF 8100 100 8100 PAVED 3374 100 3374 GRAVEL 54390 40 21756 LANDSCAPE 524371 2 10487 TOTAL 590235 7 41316 THE TRUE LIFE COMPANIES1601 19TH ST. SUITE 550DENVER, CO 80202 STOHU OHU OHU OHU OHU OHU S C.O. W S VAULT CABLE ELEC S HY DVAULT ELEC ELEC HY DW WW S S SS FO VAULT F.O. E G VAULT F.O. VAULT F.O. C C VAULT F.O. VAULT F.O.9'UE TYP.EX 4' CONCRETE PAN PROP OUTLET STRUCTURE HYLINE DRIVE LOT 1 BLOCK 1 LOT 2 LOT 3 LOT 4 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 BLOCK 2 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15 LOT 16 LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 1 LOT 2 LOT 3 LOT 5 LOT 4 TRACT F BLOCK 5 BLOCK 3 BLOCK 4 ATTIKA DRIVECHERRY SEED LANEMORELLO DRIVEBENTON LANE TULARE DRIVECHERRY SEED LANEW SWALLOW RD LOT 10 CEDAR VILLAGE 4TH FILING SILVER PLUME ESTATES HULL STREET W SWALLOW RD HULL STREET TRACT A (AE, DE, UE) WQ AND DETENTION POND TRACT C (DE) TRACT D (DE) TRACT E (PE, DE) TRACT E (PE, DE) TRACT E (PE, DE) CEDAR VILLAGE 4TH FILING SILVER PLUME ESTATES CRAWS RESUBDIVISION 6 7 8 9 FISCH DR. PART OF LOTS 5 & 6 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOTS 9 & 7 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOT 10 SUB. OF W 1 2 OF NW 1 4 27-7N-29W PART OF LOTS 5 & 6 SUB. OF W 1 2 OF NW 1 4 27-7N-29W TRACT A (CITY) LOT 3 SUB. OF W 1 2 OF NW 1 4 27-7N-29W LOT 2 SUB. OF W 1 2 OF NW 1 4 27-7N-29W LOT 1 SUB. OF W 1 2 OF NW 1 4 27-7N-29W 1 10 SILVERPLUME ESTATES SILVERPLUME ESTATES CEDAR VILLAGE 4TH 7 8 9 10 11 12 13 14 15 16 61 62 63 TRACT B (PE, DE)5090508550805 0 7 5 5 0 9 05090 508550905090 509550905 0 9 0 50955090509 0 508550905085 5 0 8 0 5080 5080 50855085509050905095509 5 5 0 9 5 5100 50 9 5 50 9 0509550905 0 9 0 50 9 0 509550855085 50755075508050805 0 8 0508050855090 50805080508550855090 BIORETENTION A BIORETENTION C UNDERGROUND WQ SYSTEM E BIORETENTION D BIORETENTION B LID EXHIBIT 2 MPO ES ES 22-100-449-00 JANUARY 11, 20234065 SAINT CLOUD DRIVE, SUITE 201LOVELAND, CO 80538PHONE: 970-834-6364www.wilsonco.comDRAWN BY: CHECKED BY: DATE:DESCRIPTIONDATEPROPERTY OWNERSEALPROJECT NAMEPROJECT NO: DESIGNED BY: SHEET NO: SHEET TITLE REV.BYPRE LI MI N A R Y S U B MI T T A L NOT F O R CON S T R U C TI O N HULL ORCHARDSSUBDIVISIONEXISTING MAJOR CONTOUR PROPOSED LID TREATMENT AREA FLOW PATH LEGEND EXISTING MINOR CONTOUR PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR PROPOSED BIORETENTION THE TRUE LIFE COMPANIES1601 19TH ST. SUITE 550DENVER, CO 80202PROPOSED UNDERGROUND WQ SYSTEM Impervious Area 324,629 sf Required Minimum Impervious Area to be Treated 162,315 sf Treatment - Underground WQ System E 35,471 sf Treatment - Bioretention A-D 135,975 sf Total impervious Area Treated 171,446 sf Actual % of Impervious Area On-Site Treated by LID 53 % 50% On-Site Treatment by LID Requirement LID Table Design Procedure Form: Extended Detention Basin (EDB) - Sedimentation Facility POND Project Name: Hull Orchards Subdivision Project Number: 21-100-449-00 Company: Wilson & Company Designer: es Date: 12/14/2022 1. Basin Storage Volume A) Tributary Area's Imperviousness Ratio (i=Ia/100) Ia = 55 % i = 0.55 B) Contributing Watershed Area (Area) A = 13.55 acres C) Water Quality Capture Volume (WQCV) WQCV = 0.220426 watershed inches (WQCV = 1.0 * (0.91 * i3 - 1.19 * i2 + 0.78i) ) D) Design Volume: Vol = WQCV/12 * Area * 1.2 Vol. = 0.30 ac-ft D04 DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method 100-Year Event LOCATION:Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 1/4/2023 Equations:A, Area trib. to pond =13.55 acre Developed flow = QD = CIA C (100) =0.80 Vol. In = Vi = T C I A = T QD Developed C A = 10.8 acre Vol. Out = Vo =K QPO T Release rate, QPO =6.70 cfs storage = S = Vi - Vo K =1 (from fig 2.1) Rainfall intensity from City of Fort Collins IDF Curve with updated (3.67") rainfall Storm Rainfall QD Vol. In Vol. Out Storage Storage Duration, T Intensity, I (cfs)Vi Vo S S (min) (in/hr) (ft3)(ft3)(ft3)(ac-ft) 5 9.95 107.9 32357 2010 30347 0.70 10 7.77 84.2 50513 4020 46493 1.07 20 5.62 60.9 73113 8040 65073 1.49 30 4.47 48.4 87187 12060 75127 1.72 40 3.74 40.5 97298 16080 81218 1.86 50 3.23 35.1 105164 20100 85064 1.95 60 2.86 31.0 111598 24120 87478 2.01 70 2.57 27.9 117046 28140 88906 2.04 80 2.34 25.4 121774 32160 89614 2.06 90 2.15 23.3 125955 36180 89775 2.06 100 1.99 21.6 129706 40200 89506 2.05 110 1.86 20.2 133112 44220 88892 2.04 120 1.75 18.9 136233 48240 87993 2.02 Required Storage Volume: 89775 ft3 2.06 acre-ft Required WQ Volume:0.30 acre-ft Total Required Volume:2.36 acre-ft DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method 100-Year Event 230109 detention (2yr historic rate).xls,FAA-100yr D05 LOCATION:Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 1/4/2023 0 20000 40000 60000 80000 100000 120000 140000 160000 0 20 40 60 80 100 120 140Volume (ft3)Storm Duration (min) Inflow Volume Outflow Volume 230109 detention (2yr historic rate).xls,FAA-100yr D06 DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method 100-Year Event 230109 detention (2yr historic rate).xls,FAA-100yr D07 LOCATION:Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es DATE: 1/4/2023 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 0 20 40 60 80 100 120 140Volume (ft3)Storm Duration (min) Storage Volume 230109 detention (2yr historic rate).xls,FAA-100yr D08 Proposed WQ and Detention Pond - Stage/Storage LOCATION: Hull Orchards Subdivision PROJECT NO: 22-100-449-00 COMPUTATIONS BY: es SUBMITTED BY: WILSON & CO DATE: la V = 1/3 d ( A + B + sqrt(A*B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour Surface Incremental Total Stage Area Storage Storage (ft)(ft2)(ac-ft) (ac-ft) 5074.0 0 5075.0 2549 0.02 0.02 5076.0 14459 0.18 0.20 WQCV-5076.3 18643 0.11 0.31 5077.0 28407 0.38 0.69 5078.0 32353 0.70 1.38 5078.5 34583 0.41 1.80 5079.0 36482 0.38 2.17 100-YR WSEL-5079.2 40022 0.18 2.36 5080.0 53338 0.84 3.20 Required Storage Volume:2.06 acre-ft Required WQ Volume:0.30 acre-ft Total Required Volume:2.36 acre-ft Proposed WQ and Detention Pond - Stage/Storage 230109 detention (2yr historic rate).xls D09 Detention PondEmergency Overflow Spillway SizingLOCATION: Hull Orchards SubdivisionPROJECT NO: 22-100-449-00COMPUTATIONS BY: esSUBMITTED BY: WILSON & CODATE: 1/5/2023Equation for flow over a broad crested weirQ = CLH3/2where C = weir coefficient = 2.6H = overflow heightL = length of the weirThe pond has a spill elevation equal to the maximum water surface elevation in the pondDesign spillway with 0.5 ft flow depth, thus H = 0.5ftSize the spillway assuming that the pond outlet is completely clogged.Pond 305Q (100) = 132 cfs (peak flow into pond)Spill elev = 5079.21 ft = 100-year WSELMin top of berm elev.= 5080.00Weir length required:L = 144 ftUse L =144ftv = 1.79 ft/sspillway, 230109 detention (2yr historic rate).xlsD10 E APPENDIX E SOILS, FLOODPLAIN AND REFERENCE MATERIALS Hydrologic Soil Group—Larimer County Area, Colorado (Hull Orchards Subdivision) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 1/3/2023 Page 1 of 444884204488460448850044885404488580448862044886604488700448874044887804488420448846044885004488540448858044886204488660448870044887404488780490420490460490500490540490580490620490660490700 490420 490460 490500 490540 490580 490620 490660 490700 40° 32' 59'' N 105° 6' 47'' W40° 32' 59'' N105° 6' 35'' W40° 32' 46'' N 105° 6' 47'' W40° 32' 46'' N 105° 6' 35'' WN Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 50 100 200 300 Feet 0 25 50 100 150 Meters Map Scale: 1:1,900 if printed on A portrait (8.5" x 11") sheet. Soil Map may not be valid at this scale. E01 MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 17, Sep 7, 2022 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Jul 2, 2021—Aug 25, 2021 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado (Hull Orchards Subdivision) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 1/3/2023 Page 2 of 4 E02 Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 3 Altvan-Satanta loams, 0 to 3 percent slopes B 12.0 95.2% 36 Fort Collins loam, 3 to 5 percent slopes C 0.6 4.8% Totals for Area of Interest 12.7 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Hydrologic Soil Group—Larimer County Area, Colorado Hull Orchards Subdivision Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 1/3/2023 Page 3 of 4 E03 Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado Hull Orchards Subdivision Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 1/3/2023 Page 4 of 4 E04 National Flood Hazard Layer FIRMette 0 500 1,000 1,500 2,000250 Feet Ü SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT SPECIAL FLOOD HAZARD AREAS Without Base Flood Elevation (BFE) Zone A, V, A99 With BFE or DepthZone AE, AO, AH, VE, AR Regulatory Floodway 0.2% Annual Chance Flood Hazard, Areas of 1% annual chance flood with average depth less than one foot or with drainage areas of less than one square mileZone X Future Conditions 1% Annual Chance Flood HazardZone X Area with Reduced Flood Risk due to Levee. See Notes.Zone X Area with Flood Risk due to LeveeZone D NO SCREEN Area of Minimal Flood Hazard Zone X Area of Undetermined Flood HazardZone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This map complies with FEMA's standards for the use of digital flood maps if it is not void as described below. The basemap shown complies with FEMA's basemap accuracy standards The flood hazard information is derived directly from the authoritative NFHL web services provided by FEMA. This map was exported on 12/13/2022 at 2:43 PM and does not reflect changes or amendments subsequent to this date and time. The NFHL and effective information may change or become superseded by new data over time. This map image is void if the one or more of the following map elements do not appear: basemap imagery, flood zone labels, legend, scale bar, map creation date, community identifiers, FIRM panel number, and FIRM effective date. Map images for unmapped and unmodernized areas cannot be used for regulatory purposes. Legend OTHER AREAS OF FLOOD HAZARD OTHER AREAS GENERAL STRUCTURES OTHER FEATURES MAP PANELS 8 B 20.2 The pin displayed on the map is an approximate point selected by the user and does not represent an authoritative property location. 1:6,000 105°7'14"W 40°33'5"N 105°6'36"W 40°32'38"N Basemap: USGS National Map: Orthoimagery: Data refreshed October, 2020 E05 4065 St. Cloud, Suite.201 Loveland, CO 80538 970-834-6364 phone