HomeMy WebLinkAboutPOWERHOUSE 2 - FDP220015 - SUBMITTAL DOCUMENTS - ROUND 1 - VARIANCE REQUEST (3)Stormwater
Alternative Compliance/Variance Application
City of Fort Collins Water Utilities Engineering
Section A: Engineer/Owner Information
Engineer Name____________________________________________Phone___________________________
Street Address_____________________________________________________________________________
City__________________________________________State________________________Zip_____________
Owner Name______________________________________________Phone___________________________
Street Address_____________________________________________________________________________
City__________________________________________State________________________Zip_____________
Section C: Alternative Compliance/Variance Information
Section B: Proposed Project Information
Legal description and/or address of property____________________________________________________
Project Name______________________________________________________________________________
Project/Application Number from Development Review (i.e. FDP123456)__________________________
Description of Project_______________________________________________________________________
__________________________________________________________________________________________
Existing Use (check one): ☐ residential ☐ non-residential ☐ mixed-use ☐ vacant ground
Proposed Use (check one): ☐ residential ☐ non-residential ☐ mixed-use ☐ other____________________
If non-residential or mixed use, describe in detail_______________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
State the requirement from which alternative compliance/variance is sought. (Please include
applicable Drainage Criteria Manual volume, chapter and section.)
What hardship prevents this site from meeting the requirement?
What alternative is proposed for the site?
Attach separate sheet if necessary
Attach separate sheet if necessary
page 2
The owner agrees to comply with the provisions of the zoning ordinance, building code and all other
applicable sections of the City Code, Land Use Code, City Plan and all other laws and ordinances
affecting the construction and occupancy of the proposed building that are not directly approved by
this variance. The owner understands that if this variance is approved, the structure and its occupants
may be more susceptible to fl ood or runoff damage as well as other adverse drainage issues.
Signature of owner:_____________________________________________Date:_______________________
The engineer hereby certifi es that the above information, along with the reference plans and project
descriptions is correct.
Signature of engineer:___________________________________________Date:_______________________
PE STAMP
If you have questions or need assistance fi lling out forms, contact Fort Collins Utilities at:
Phone: 970-221-6700 · TDD 970-224-6003
Web: fcgov.com/stormwater · Email: WaterUtilitiesEng@fcgov.com
UtilitiesOffice use onlyDate complete application submitted:_____________
Date of approval/denial:__________________________ Variance: ☐ approved ☐ denied
Staff justifi cation/notes/conditions:_______________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
________________________________________________________________________________________
Approved by:__________________________________
Entered in UtilityFile Database? ☐ yes ☐ no