HomeMy WebLinkAboutTRIPLE CROWN SPORTS EXPANSION - MA220144 - DOCUMENT MARKUPS - ROUND 1 - UTILITY PLANS1330.12'EXISTING BUILDING FFE = 4954.2AUTOMATION WAYUPSIZE TO 1.5" WATER SERVICE 5' DOWNSTREAM OF METER PROPOSED 1" WATER METER IN EXISTING METER PIT EXISTING TREE (TYP) EXISTING TREE (TYP) EXISTING TREE (TYP) 20' DRAINAGE AND UTILITY EASEMENT 15' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT EXISTING SOFTBALL FIELD EXISTING SOFTBALL FIELD EXISTING BULLPEN AREA EXISTING IRRIGATION METER & BACKFLOW PREVENTION DEVICE EXISTING HEADWALL HEADWALL AND 15" RCP STORM DRAIN EXISTING DUG OUT EXISTING TREE (TYP)EXISTING METAL BENCH EXISTING METAL BENCH GRASS FIELD EXISTING WALK EXISTING LIGHT POLE EXISTING LIGHT POLE EXISTING BATTING CAGEEXISTING BURIED ELECTRIC EXISTING HEADWALL AND 24" RCP STORM DRAIN EXISTING BURIED ELECTRIC EXISTING BURIED ELECTRIC & TELECOM LINES EXISTING BURIED GAS EXISTING TELECOM EQUIPMENT EXISTING TRANSFORMER EXISTING BURIED ELECTRIC EXISTING TELECOM LINE EXISTING GAS LINE EXISTING 8" WATER MAIN EXISTING BURIED ELECTRIC EXISTING CLEANOUT EXISTING CLEANOUT EXISTING TREE (TYP) EXISTING TREE (TYP) EXISTING 8" WATER MAIN EXISTING 1.5" IRRIGATION SERVICE EXISTING BURIED ELECTRIC EXISTING GAS LINE EXISTING IRRIGATION BOX (TYP) EXISTING IRRIGATION BOX (TYP) EXISTING GAS LINE EXISTING IRRIGATION BOX (TYP) EXISTING IRRIGATION BOX (TYP) EXISTING ELECTRIC EQUIPMENTEXISTING LIGHT POLE EXISTING ELECTRIC EQUIPMENT EXISTING TYPE R INLET EXISTING ELECTRIC EQUIPMENT EXISTING ELECTRIC EQUIPMENT EXISTING ELECTRIC EQUIPMENT EXISTING IRRIGATION BOX (TYP) EXISTING GAS SERVICE EXISTING GAS METER EXISTING WALK EXISTING 5' PUBLIC SERVICE COMPANY EASEMENT EXISTING 24" RCP STORM DRAIN EXISTING 15" RCP STORM DRAIN EXISTING 5' TYPE R INLET EXISTING 5' TYPE R INLET TIMBERLINE ROADPROPOSED STORM SEWER (SEE SHEET C3.10) PROPOSED DRAINAGE & UTILITY EASEMENT EXISTING 6" FIRE SERVICE TO REMAIN PROPOSED 1" WATER SERVICE LOT 1 COLLINDALE BUSINESS PARK NINTH FILING LOT 2 COLLINDALE BUSINESS PARK NINTH FILING PROPOSED BUILDING ADDITION SAWCUT AND REMOVE EXISTING ASPHALT WITH REMOVAL AND REPLACEMENT OF EXISTING WATER SERVICE (SEE NOTES 6 & 7) EXISTING FIRE HYDRANT 1" = 30' 1" = N/A 12/7/202210:49:15 AMC:\UNITED CIVIL DROPBOX\PROJECTS\U22030 - TRIPLE CROWN SPORTS\CADD\CP\C3.00 - UTILITY PLAN.DWGC3.00 - UTILITY PLANSMEJRSC3.00UTILITY PLAN7 PREPARED FOR:JOB NUMBER SHEET NUMBER SHEETSOF DATE SUBMITTED:VERTICAL: HORIZONTAL: SCALEPRELI MINA RY PLANSNOT F O R C O NSTR U CTI O N PROJ. MGR:DRAWING NAME:PATH:DESIGNER:DATE:TIME:The engineer preparing these plans will not be responsible for, or liable for,unauthorized changes to or uses of these plans. All changes to the plansmust be in writing and must be approved by the preparer of these plans.NO.BYDATECAUTIONREVISIONS:CIVIL ENGINEERING & CONSULTING UNITED CIVIL Design Group 19 OLD TOWN SQUARE #238 FORT COLLINS, CO 80524 (970) 530-4044 www.unitedcivil.com TRIPLE CROWN SPORTSU22030TRIPLE CROWN SPORTS EXPANSION14 12/7/2022NORTH0 30'60' SCALE: 1" = 30' 15' LEGEND DS DOMESTIC SERVICE LINE AND METER FIRE DEPARTMENT CONNECTION DOWNSPOUT, ROOF DRAIN, AND ROOF OVERFLOW STORM PIPE AND DRAIN BASIN ELECTRIC LINE AND TRANSFROMER GAS LINE AND METER LIGHT POLE RD OVF G FDC UTILITY NOTES 1.ALL EXISTING UTILITIES ARE APPROXIMATELY SHOWN AND LOCATIONS NEED TO BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 2.THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 3.REFER TO APPROVED SITE ELECTRICAL PLANS FOR ALL LIGHTING, TELECOM CONDUITS (PHONE, TELEVISION AND FIBER) AND POWER LINE ROUTING FOR SITE LIGHTING. 4.THE CONTRACTOR SHALL CONTACT THE UTILITY NOTIFICATION CENTER OF COLORADO (UNCC) AT 811 OR 1-800-922-1987, TO HAVE LOCATIONS OF UNCC REGISTERED LINES MARKED BY MEMBER COMPANIES. ALL OTHER UNDERGROUND FACILITIES SHALL BE LOCATED BY CONTACTING THE RESPECTIVE OWNER. 5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION AND DEPTH OF ALL EXISTING UTILITIES AS NECESSARY TO ENSURE THE UTILITIES WILL NOT BE IMPACTED BY CONSTRUCTION ACTIVITIES. 6.LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS SHALL BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7.CONTRACTOR SHALL COORDINATE WITH WATER UTILITIES ON THE ABANDONMENT/REMOVAL OF THE EXISTING 3/4-INCH WATER SERVICE. NOTE THAT WATER SERVICE SHALL BE ABANDONED AT THE MAIN PER CITY REQUIREMENTS. SANITARY SERVICE AND CLEANOUT FIRE LINE Pavement replacement and street cuts should span the entire width of a lane. No partial lane pavement replacements are allowed.