HomeMy WebLinkAboutFISCHER PROPERTIES - PDP220007 - DOCUMENT MARKUPS - ROUND 3 - RESPONSE TO STAFF REVIEW COMMENTS (3)WEST PROSPECT ROAD SOUTH SHIELDS STREET57' RIGHT-OF-WAY RESIDENTIAL LOCAL STREET (WITH PARKWAY)7' PARKING8.5' PARKWAY5' SIDEWALK9' UTILITY EASEMENT DRIVE-OVER CURB & GUTTER ℄ 4:1 MAX 30' - 15' -℄7' PARKING8.5' PARKWAY5' SIDEWALK9' UTILITY EASEMENT DRIVE-OVER CURB & GUTTER 4:1 MAX 15' -℄ 16' TRAVEL LANE C 100COVER SHEET 1 Original Field Survery: Northern Engineering Project No. 1382-001 Date: August 07,2017 AUGUST 2022 CONTACT INFORMATION PROJECT TEAM: VICINITY MAPNORTH Project Datum: NAVD88 Benchmark PAULUS On the East edge of a double manhole Type R Inlet, 15 feet South of a concrete multi-use trail tunnel, 7 feet West of top back of curb near the Southwest corner of Shields St. and Elizabeth St. Elevation: 5025.82 Benchmark CSU2 The mark is a standard brass Larimer County geodetic control disk set in 2002, in the campus of Colorado State University approx. 240.8 feet South from the center line of North Drive, 46.6 feet Northeast from the edge of CSU Lagoon, 33 feet Southwest from the center of the delivery road to the University Club and 1.1 feet Southwest from the edge of the sidewalk. Elevation: 5006.29 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (Prior City of Fort Collins datum) for their vertical datums. If NGVD29 unadjusted datum (Prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 = NAVD88 - 3.17' Basis of Bearings The East line of the Northeast Quarter of the Southeast Quarter of Section 15, Township 7 North, Range 69 West of the 6th P.M. as bearing South 00° 29' 40" West (assumed). PROJECT BENCHMARKS: FISCHER PROPERTIES PROJECT TEAM: OWNER/APPLICANT SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO FIELD SURVEY BY: TYPICAL SECTIONS 1 C 100 COVER SHEET 2 C 101 GENERAL & CONSTRUCTION NOTES 3 C 200 EXISTING CONDITIONS & DEMOLITION PLAN 4 C 300 CIVIL SITE PLAN UTILITY SHEETS 5 C 400 OVERALL UTILITY PLAN 6-7 C 401-C 402 UTILITY PLAN GRADING SHEETS 8 C 500 OVERALL GRADING PLAN 9-10 C 501-C 502 GRADING PLAN ROADWAY SHEETS 11 C 600 LAKEWOOD DRIVE PLAN & PROFILE 12 C 601 WESTWARD DRIVE RIGHT FLOWLINE - PLAN & PROFILE 13 C 602 DEL MAR STREET RIGHT FLOWLINE - PLAN & PROFILE 14 C 603 DEL MAR STREET & LAKEWOOD DRIVE INTERSECTION DETAIL DRAINAGE SHEETS 15 C 700 HISTORIC DRAINAGE EXHIBIT 16 C 701 DRAINAGE EXHIBIT UTILITY PLANS FOR CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 APPROVED: City Engineer:Approved Sheets Date Water & Wastewater Utility Approved Sheets Date Stormwater Utility Approved Sheets Date Park Planning and Development Approved Sheets Date Traffic Operations Approved Sheets Date Environmental Planner Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: PROJECT LOCATION Ripley Design, Inc. Russ Lee, President 419 Canyon Avenue, Suite 200 Fort Collins, CO. 80521 (970) 224-5828 Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R N GI EHTRON RN E N G I N E E R N GI EHTRON RN PLANNER/ LANDSCAPE ARCHITECT SITE ENGINEER SURVEYOR ■ land planning ■ landscape architecture ■■ urban design ■ entitlement ■ Erik Fischer 125 S. Howes Street, Suite 900 Fort Collins, CO 80521 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy----------------------------- Pat Kreager (970) 225-7840 ELECTRIC-------- City of Fort Collins Light & Power-- Cody Snowdon (970) 416-2306 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities----------- Heidi Hansen (970) 221-6854 STORMWATER- City of Fort Collins Utilities----------- Heidi Hansen (970) 221-6854 Additional Survery: Northern Engineering Project No. 1382-002 Date: March 23, 2022 X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D VAULT ELEC C VAULT ELEC D D D C ECC CCCC VAULT ELEC C C C C STS S S S S S 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS SSSS15" SSSTSTSTSTSTSTSTSTSTSTSTSTS T 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSSTCTVCTVCTV CTVCTVCTVCTVGGGCTV CTV GGGGEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV VAULT CABLE C VAULT CABLE OHU OHU OHU OHU OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W CTV CTV CTV CTV CTV CTV CTVCTV CTV 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SSWWWWWWWWWWWWW W SSSSSSSSSSSSSSSSSSSSSSSSWEWE E E E E E G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOE EEWWGGGGGGGGW W W W FOEFOG G G E E E E FO FO FO E W WWWWFO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E EES W ELEC WCS W ELEC VAULT TELE ELEC W W M M M S W F.O. F.O. D D C SCS CABLE FO FO FOFGGGGGGGGT T G G G G E E E E E E E E E EEEEEEEEEE E EEEES FDC EEEEEWNYLOPLASTDO NOT P O L L U T E DRAINS TOWATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UD NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWA Y S DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOP L AS T DO NOT PO L L UT EDRAINS TO WATERW A YS DO NOT PO L L U TE D RA I N S TO W A TE R W A YS NYLOPLAS T D U C T I LE I R ON / / / / / / / /PROPOSED 8" PVC SANITARY SEWER PROPOSED 8" WATER MAIN CONNECT TO EXISTING 4" WATER MAIN CONNECT TO EXISTING 6" WATER MAIN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 3 4" UNDERDRAIN 30' SANITARY SEWER EASEMENT PROPOSED STORM DRAIN PROPOSED STORM DRAINPROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 PROPOSED FIRE HYDRANT PROPOSED SIDEWALK CULVERT PROPOSED SANITARY SERVICE PROPOSED FIRE SERVICE PROPOSED WATER METER PROPOSED FIRE HYDRANT CONNECT TO EXISTING STORM DRAIN 9' DRAINAGE & UTILITY EASEMENT 5' UTILITY EASEMENT SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW5' SIDEWALK5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED FIRE HYDRANT EXISTING ELECTRIC LINE EXISTING CABLE TV LINE PROPOSED 2' SIDEWALK CULVERT (TYP.) PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN DETENTION POND 1 CONNECT TO REPLACED 8" SANITARY SEWER LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 BLOCK 1 BLOCK 1 TRACT B AE,DE,UE EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING 8" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER EXISTING 6" CAST IRON WATER MAIN EXISTING 15" PVC SANITARY SEWER EXISTING 21" RCP STORM DRAIN EXISTING GAS LINE EXISTING 10" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER MAIN EXISTING GAS LINEEXISTING ELECTRIC LINE EXISTING 24" RCP STORM DRAIN EXISTING 18" RCP STORM DRAIN EXISTING 4" CAST IRON WATER MAIN EXISTING 8" CLAY SANITARY SEWER EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE PROPOSED 2' CONCRETE PAN PROPOSED ROOF DRAIN (TYP.) OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. APPROXIMATE LOCATION CONNECT TO EXISTING 3-PHASE POWER PROPOSED TRANSFORMER PROPOSED TRANSFORMER CONNECT TO EXISTING STORM DRAIN 6' SIDEWALK 6' SIDEWALK6' SIDEWALK30' SANITARY SEWER EASEMENT TRACT A AE,DE,UE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 C 400OVERALL UTILITY PLAN 5 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11. ALL WATER SERVICES SHALL BE 34" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 X X X X X X X XXX X XXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXX CCCC VAULT ELEC C C C C CTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHUOHUOHU OHU 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSE E EEEEWWWWWGGGGGGGGGGGGGGGGGGW W W WWWWWWWWWFO FO FO S S / / / / / / / // / / / / / / // / / / / / / /GGGGGGGGGGEEEEEEEEEUDUDUDUDUDUDUDUDPROPOSED 8" PVC SANITARY SEWER PROPOSED 8" PVC WATER MAIN CONNECT TO EXISTING 4" WATER MAIN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 1 PROPOSED UNDERDRAIN 30' SANITARY SEWER EASEMENT CONNECT TO REPLACED 8" SANITARY SEWER PROPOSED FIRE HYDRANT 5' UTILITY EASEMENT 5' UTILITY EASEMENT DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW PROPOSED FIRE HYDRANT LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT RAINGARDEN ABLOCK 1 BLOCK 1 PROPOSED 2' CONCRETE PAN EXISTING 4" CAST IRON WATER LINE RAIN GARDEN BIOMEDIA AREA 3' DRAINAGE EASEMENT (TYP.) PROPOSED 2' SIDEWALK CULVERT PROPOSED 2' SIDEWALK CULVERT PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE EXISTING ELECTRIC LINE EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING GAS LINE EXISTING 4" CAST IRON WATER MAIN EXISTING 8" CLAY SANITARY SEWER EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. ±39' FL-FL 60' ROW 5' SLOPE EASEMENT PROPOSED 2' SIDEWALK CULVERT TRACT A AE,DE,UE 30' SANITARY SEWER EASEMENT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 402C 401UTILITY PLAN 6 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11. ALL WATER SERVICES SHALL BE 34" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 X X X X XXXXXX X X XXXXXXXXXXXXXXD D VAULT ELEC C VAULT ELEC D D C ECC C C S S8" SS 8" SS 8" SS SSSS STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T ST 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSCTVCTVCTVCTVCTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV GGGGGGGEEEEEEEEEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTVVAULT CABLE C VAULT CABLE OHU OHU OHU OHUOHUOHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E E E E E E 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CT V CTVCTV CTV CTV CTV CT V W W WSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWEEWWE E E E E E E E E E E G G G G G G G G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E E E E E E EEES ELEC WCS ELEC VAULT TELE ELEC W W M M M C SCS FO FO FO FO FOFOFGGGGGGGGGGGGGGG G G GTT GG G G G G G G G E E E E E E E E E E E E E E E E E EEEEEEEEEEEEEEEEEEEE E E E E EEEEEE E E ESFDC EEEEEEEEEEWNYLOPLASTDO NOT POLLUTEDRAINS TOWATERWAYSDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUD UD UD UD UD UD UD UD UD UD UD NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWAYSDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPL A S T D U C T I L E I R O NUDUDUDUDUD DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOPLAS TDO NO T P OL LU TEDRAIN S TOWATER WA YS DO NO T P OL L UT E D RA I NS TO W A TE RW AY S NYLO P LA ST DU C TI L E I RO N CONNECT TO EXISTING 6" WATER MAIN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 1 PROPOSED DETENTION POND 1 30' SANITARY SEWER EASEMENT CONNECT TO REPLACED 8" SANITARY SEWER PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH CHAMBERS PROPOSED SANITARY SERVICE PROPOSED FIRE SERVICE PROPOSED WATER METER PROPOSED FIRE HYDRANT CONNECT TO EXISTING STORM DRAIN SOUTH SHIELDS STREETWESTWARD DRIVE 6' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALKLOT 1 PROPOSED 2' SIDEWALK CULVERT PROPOSED STORM DRAIN PROPOSED UNDERDRAIN PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE DRAINAGE EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING 8" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER EXISTING 15" PVC SANITARY SEWER EXISTING 21" RCP STORM DRAIN EXISTING GAS LINEEXISTING ELECTRIC LINE EXISTING 18" RCP STORM DRAIN OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. 26' EMERGENCY ACCESS EASEMENT PROPOSED ROOF DRAIN ±37' FL-FL 60' ROW PROPOSED TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE LOCATION CONNECTION TO 3-PHASE POWER AT CORNER OF SPRINGFIELD DRIVE & SHIELDS STREET PROPOSED FDC PROPOSED 2' SIDEWALK CULVERT DRAINAGE EASEMENT DRAIN BASIN w/ 100-YR WEIR DRAIN BASIN w/ WQ WEIR CONNECT TO EXISTING STORM DRAIN PROPOSED CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN ISOLATOR ROWS 30' SANITARY SEWER EASEMENT PROPOSED UNDERGROUND DETENTION POND 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 401 C 402UTILITY PLAN 7 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3. ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10. ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11. ALL WATER SERVICES SHALL BE 34" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 NYLOPLASTDO NOT P O L L U T E DRAINS TOWATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UD NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWA Y S DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOP L AS T DO NOT PO L L UT EDRAINS TO WATERW A YS DO NOT PO L L U TE D RA I N S TO W A TE R W A YS NYLOPLAS T D U C T I LE I R ON X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D D D D STSTSTSTSTSTSTSTSTSTSTSTSTS T STD D / / / / / / / /SOUTH SHIELDS STREETSPRINGFI E L D D RI V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 6' SIDEWALK6' SIDEWALK6' SIDEWALK 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW RAIN GARDEN BIOMEDIA AREA DETENTION POND 3 DETENTION POND 1 5' SIDEWALK5' SIDEWALKPROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED AREA DRAIN PROPOSED STORM INLET PROPOSED CURB INLET 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 TRACT B AE,DE,UE EXISTING 18" STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' SIDEWALK CULVERT PROPOSED 2' SIDEWALK CULVERT PROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 FFE=32.92 OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. ± 37' FL-FL EXISTING 60' ROW EXISTING ±64' FL-FL ±40' FL-FL 60' ROW 40' FL-FL EXISTING ±50' HALF ROW PROPOSED MULTI-FAMILY BUILDING PROPOSED CURB INLET PROPOSED CURB INLET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R C 500OVERALL GRADING PLAN 8 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5. LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45)EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE C 502C 501 X X X X X X X XXX X XXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXX/ / / / / / / // / / / / / / // / / / / / / /UDUDUDUDUDUDUDUD32 . 4 036.6130.28 31.6630.8930.9031.0931.2131.6732 . 4 231.6731.79 31.6431.800.6% 3.2%2.5%0.5%0.2%2.9%DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 5' SIDEWALK1.3% LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED DETENTION POND 3 RAINGARDEN A(35.22)(3 4 . 3 9 )(33.70)32.90 33.9134.3035.63 35.6434.303 3 . 9 1 32.92 (35.24)(35.85)(3 6 . 5 9 )(37.66)(3 8 . 8 5 ) 31.26 31.23 31.43 BLOCK 1 BLOCK 1 RAIN GARDEN BIOMEDIA AREA PROPOSED 2' CONCRETE PAN 30' FL-FL57' ROW 30' SANITARY SEWER EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT 3' DRAINAGE EASEMENT (TYP.) PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE PROPOSED 2' SIDEWALK CULVERT 6" RIBBON CURB RAIN GARDEN BIOMEDIA AREA(36.33)(3 5 . 7 8 ) (4 0 . 8 2 ) (35. 0 1 )(33.39)(33.90)31.9331.1331.6030 . 9 7 31.4631.3931.2431.2931.45(33.35)(36.90)37.0138.1637.5936.0735.5933 . 3 0 33.9232.54 32.44 32.4733.3033.9338.0039.0 9 30.2 8 30.2831 . 1 7 26.8326.9927.2732.1932.1631.5630.2830.3130.31 30.3131.8530.313 0 . 3 1 RAINGARDEN A31.12OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. ±39' FL-FL 60' ROW 31.0 8 32.3226.98 32 . 1 7 3 2 . 5 9 31.68 27.380.5%0.5% 26.88 0.6% PROPOSED 2' SIDEWALK CULVERT 1.0%3.5%0.5%0.5%0.5%2.0% 2.0%0.5%2.0%2.1%1.6%1.0%30.3131.7231.6231.9032.0032.0732.0331.4 131.5031.8831 . 7 931.7131.762.2% 0 . 5% 0.5 % 2.6%0.6%31.500.5%31.59PROPOSED 2' SIDEWALK CULVERT 31.1131.02 30.9832.1731.96 32.04 30.8731.2131.3 1 30.2 8 30.2831.3131.16 27.5127.5132.8032.76 33.2629.2028.6427.5927.7927.1734.1435.1735.3334.1934.1234.0433.7527.6227.1526.8527.65SLOPE EASEMENT 31.8132 . 0 132.1032.0032.0231.9731.8531 . 2 3 2.7%2.0%2.6%2.8%2.1% 2.1% 1.9%2.1%2.3%2.3% 2.0% 2.2%2. 8 %2.5%4.8% 2.8 %5.6%4: 1 6:1 4:16: 15:15:14:1 4:1 4:1 4:1 4:1 4:1 4:18:16:11.0%6' SIDEW AL K 6' SIDEWALK TRACT A AE,DE,UE TRACT A AE,DE,UE 0.8%0. 6%0.5%2.4%2.1%1.1%31 . 4 6 PROPOSED SIDEWALK CULVERT NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R MATCH LINE - SEE SHEET C 502C 501GRADING PLAN 9 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5. LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45)EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA C 502 C 501 X X X X XXXXXX X X XXXXXXXXXXXXXXD D D D STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T ST FDC NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWAYSDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUD UD UD UD UD UD UD UD UD UD UD NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWAYSDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPL A S T D U C T I L E I R O NUDUDUDUDUD DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOPLAS TDO NO T P OL LU TEDRAIN S TOWATER WA YS DO NO T P OL L UT E D RA I NS TO W A TE RW AY S NYLO P LA ST DU C TI L E I RO N 31.6630.8930.9031.0931.2131.6731.4731.003 1 . 3 9 31.063 1 . 1 7 31.6332 . 4 231.6731.79 31.6431.803 1 . 4 9 28.210.6% 3.2%2.5%0.6%2.9%0.5%0.5%0.5%0.2%1.0%2.1%2.4%2.1%2.9%SOUTH SHIELDS STREETWESTWARD DRIVE 5' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALK27.87(27.62)(31.13)30.350.8%1.4%1.3% 0.6%0.5%PROPOSED DETENTION POND 1 31 . 0 4 31.04 31.10 31.1030.55 30.55 30.80 30.85 31.26 31.23 31.43 31.23 31.23 31.51 31.48 30.9 031.7630 . 9 6 30 . 9 8 TRACT B AE,DE,UERAIN GARDEN BIOMEDIA AREA PROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED STORM INLET PROPOSED CURB INLETPROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 DRAINAGE EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 30' SANITARY SEWER EASEMENT 26' EMERGENCY ACCESS EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE RAIN GARDEN BIOMEDIA AREA PROPOSED POND OUTLET STRUCTURE 26' EMERGENCY ACCESS EASEMENT CONNECT TO EXISTING STORM DRAIN EXISTING 21" RCP STORM DRAIN EXISTING 18" RCP STORM DRAIN PROPOSED TRASH ENCLOSURE FFE=32.92 26' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT (33.39)(3 3 . 9 0 )(30.65)(30.53)27.71 27.90 28.09 (28.12)(28.60)(29.00)(29.50)(30.43)30.74 30 . 7 330.6831.3031.4231.9331.1331.6030 . 9 7 31.4631.2531.3931.2431.2931.4531.2 431.4131.6431.8531.9931.6530.89 30.9 8 31.37 32.14(3 3 . 3 5 )30.2831 . 1 7 26.8332.1932.1630.6630.6331.5630.2830.3131.8530.3110.3%0.5%29.7632.7332.3732.9231.040.5%OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. ±37' FL-FL 60' ROW PROPOSED ROOF DRAIN (TYP.) BIKE BARN (RE: LANDSCAPE) BIKE BARN (RE: LANDSCAPE)31.4031.6529.8131.8631.8431.4431.3830.7632.2532.25 32.2532.2532.0532.2531.5231.0629.1629.4330.5931.3431.9232.1227.520.5%31.7532.0831.2531.3227 . 7 030.4730.9430.4530.6431.2332.2532.0432.9231.7932.2231.5232.2531.4132.2531.2832.2431.3432.0331.5631.1431.0831.1231.0 8 31.0531.4 0 31.3 1 31.1031.7831 . 9 731.9231.7232.9232.2531.8331.0031.6431.4631.1231.9631.7631.6431.3531.4631.4831.5 331.2731.3232.3226.98 32.173 2 . 5 9 31.68 27.3826.88 0.6% PROPOSED 2' SIDEWALK CULVERT 1.0%3.5%0.5%0.5%0.5%2.0% 2.0%0.5%2.0%2.1%1.6%1.0%30.3131.7231.6231.9032.0032.0732.0331.4 131.5031.8831 . 7 931.7131.762.2% 0 . 5% 0.5 % 2.6%0.6%31.50 30.26 30.830.8%0.5%31.0331.3630.6230.700.5%PROPOSED 2' SIDEWALK CULVERT 31.1130.6330.3630.2031.1631.6631.1631.3431.0230.10 29.1129.1127.9928.2328.2 3 28.4 8 28.4830.9130.9128 . 2 4 28.0830.8631.0530.7731.0530.8429.5228.8230.6727.97 28.1 4 31.3430.9130.590.8%30.9130.7531.1331.1331.4431.3631.8932.2531 . 6 631.250.5%1.5%1.5% 31.02 30 . 9 8 32.04 30.8730.2831.3131.16 34.1934.1234.0433.7527.6227.1526.8527.6531.8132 . 0 1 32 . 1 0 32.0032.0231.9731.8531 . 2 3 2.7%2.0%2.6%2.8%2.1% 2.1% 1.9%2.1%2.3%2.3% 2.0% 2.2%2.8%2.5%2.8%1. 6%1.6%1.8%2.2%2.1%1.6%3.4% 2.4%2.0%2.1%5.6%6: 15:15:14:1 4:1 4:1 6:14:14:18:14:1 4:1 4:1 4:1 5:1 5:1 10:1 9:1 8:14:16:1 5:1 4:1 4:1 7:1 6:15:16:17.9%6:1 31 . 7 431.4531 . 6 531.9931.58 31 . 2 91.0%1.0%6' SIDEWALK 0.8%0. 6%0.5%2.4%2.1%1.1%31 . 4 6 PROPOSED CURB INLET PROPOSED CURB INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET 31.25PROPOSED AREA INLET PROPOSED 2' CONCRETE PAN32.921.0%0.7%31.5732.252.0%2.3%32.8232.3432.331.5%1.5%3.2% 2.0% KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R C 502GRADING PLAN 10MATCH LINE - SEE SHEET C 501 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5. LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45)EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA C 502 C 501 X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D D D D STSTSTSTSTSTSTSTSTSTSTSTSTS T STF.O. F.O. D D / / / / / / / /0.52 ac. OS-2 GGGGGGGGT T G G G G E E E E E E E E E EEEEEEEEEE E EEEE FDC EEEEENYLOPLASTDO NOT P O L L U T E DRAINS TOWATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UD NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWA Y S DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOP L AS T DO NOT PO L L UT EDRAINS TO WATERW A YS DO NOT PO L L U TE D RA I N S TO W A TE R W A YS NYLOPLAS T D U C T I LE I R ON / / / / / / / /2.24 ac. 200 100 2.31 ac. 300 0.40 ac. OS-3 0.93 ac. OS-4 0.13 ac. OS-1 200 300 STORMTECH CHAMBERS 2 PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN OS-2 OS-1 OS-3 OS-4 PROPOSED UNDERDRAIN PROPOSED SIDEWALK CULVERT PROPOSED UNDERDRAIN 5' SIDEWALK 5' SIDEWALK SOUTH SHIELDS STREETSPRING FI E L D D RI V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE EXISTING STORM DRAIN EXISTING STORM DRAIN 9' UTILITY EASEMENT 9' UTILITY EASEMENT DETENTION POND 3 EXISTING 24" STORM DRAIN LOT 3 LOT 4 LOT 1 LOT 2 LOT 5 LOT 7 LOT 6 LOT 9 LOT 8 BLOCK 1 BLOCK 1 TRACT B AE,DE,UE 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. 100-YR WSEL 100-YR WSEL 0.84 ac. 100 PROPOSED 2' CONCRETE PAN 0.04 ac. OF-2 0.23 ac. OF-1 DETENTION POND 1 UNDERGROUND DETENTION POND 2. RAIN GARDEN A LID VOL. = 2,152 CU.FT. LID WSEL = 5031.31 OF CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow.before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1. REFER TO THE PRELIMINARY DRAINAGE REPORT FOR FISCHER PROPERTIES BY NORTHERN ENGINEERING, DATED AUGUST 24, 2022 FOR ADDITIONAL INFORMATION. A LEGEND: C 701DRAINAGE EXHIBIT 16 FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION Rational Flow Summary | Developed Basin Flow Rates BASIN TOTAL AREA (acres) Tc2 (min) Tc100 (min) C2 C100 Q2 (cfs) Q100 (cfs) 100 0.60 6.9 6.9 0.63 0.69 0.99 3.76 200 1.83 5.0 5.0 0.83 0.89 4.33 16.20 300 2.64 6.5 6.5 0.61 0.70 4.18 16.74 OF-1 0.23 7.4 7.4 0.33 0.39 0.19 0.77 OF-2 0.04 5.0 5.0 0.70 0.75 0.08 0.31 OS-1 0.13 5.0 5.0 0.81 0.86 0.31 1.13 OS-2 0.52 10.8 10.8 0.44 0.50 0.49 1.96 OS-3 0.40 8.8 8.8 0.43 0.49 0.40 1.60 OS-4 0.93 10.4 10.4 0.33 0.39 0.68 2.79 POND SUMMARY TABLE Pond ID Extended Detention WQCV (CF) LID WQCV (CF) 100-Yr. Detention Vol. (CF) Total Volume (CF) 100-Yr. Detention WSEL(Ft) Peak Release (cfs) Pond 1 546.00 N/A 2,832.00 3,378.00 5,030.03 0.40Pond 2 N/A 2,209.00 9,843.00 12,052.00 5,029.40 1.99Pond 3 N/A 2,213.00 16,562.00 18,775.00 5,031.27 1.10 LID Site Summary - New Impervious Area Total Area of Current Development 232,598 ft2 Total On-site Impervious Area 143,631 ft2 75% Required Minimum Area to be Treated by LID 107,723 ft2 Total On-site Impervious Area Treated by LID 127,813 ft2 Percent On-site Impervious Treated by LID 88.99% Additional Off-site Impervious Area Treated by LID 9,176 ft2 Percent Total Impervious Area Treated by LID 95.38% Total Impervious Area Treated by Traditional WQ 13,385 ft2 Percent Impervious Treated by Traditional Water Quality 9.32% Percent Impervious Area Treated by Traditional WQ or LID 104.70%