HomeMy WebLinkAboutFRONT RANGE FARMS II - REZONING - 56-87A - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWCONCEPTUAL REVIEW STAFF COMMENTS
of
MEETING BATE: June 1, 1998
TEEM: Front Range Farms - Multi -Family Residential
APPLICANT: Mr. Dale Snyder cto Mr. Tom Dugan, Pineca est Planning and Design, 4225
Westshore Way, Fort Collins, CO.80525, and Mr. Mark Obetuhmidt,
Shear Engineering, 4836 South College Avenue, Fort. Collins, CO. 80525
LAND USE DATA: Request for approximately 200 duplex dwelling units (in 100 buildings) on
40 acres located on the eastern half of Front Range Farms at the northeast
corner of I-25 and East Vine Drive.
COMMENTS:
1. The site is currently zoned "I," Industrial which does not allow residential; A request to
rezone the property would have to be submitted prior to submitting a Project
Development. Plan. Rezoning requests are processed twice per year in the Spring and Fall.
Rezonings will be evaluated by the guidance and criteria of the City's comprehensive plan
known as City Plan. This includes a generalized land use map called Structure Plan which
indicates that the subject property is "Industrial" and
"Rural Open Lands and Stream Corridors." Therefore, a request to rezone to "Low
Density Mixed -Use Residentiar' would not be supported by City Plan. As applicant, you
would bear the burden of proof to demonstrate that Structure Plan is either in error or that
conditions have sufficiently changed in order to warrant a change to the Structure Plan.
lWaoreweriT
2. As you have acknowledged, the p does not have et sufficient contiguity � . att y this time
to be considered eligible for The Land Use Code requires that at least one -
sixth of the proposed development's boundaries must be contiguous to existing urban
development within either the city or unincorporated Larimer County within the Urban
Growth Area. If the development is a phase of an Overall Development Plan which
complies with the contiguity requirement of this Section, and if all portions of the phase
are within one-half mile of existing urban development, then the development phase need
not comply with such requirement. A definition of "existing urbwl development" is
provided in the Land Use Code Section 3.7.2 (ArticleThree, page 113).
3. An Overall Development Plan (O.D.P.)may be required in addition to a Project
Development Plan (P.D.P.). If the applicant desires to develop in two or more separate
Project. Development Plan (P.D.P.) submittals, then an Overall Development Plan
(O.D.P.) will also be required prior to or concurrently with the P.D.P. Please refer to
Section 2.3 (Article Two, page 33) for specific requirements for O.DP.'s.
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750
CURRENT PLANNING DEPARTMENT
4. If the project is to be submitted under the L-M-N zone district, then please note that there
are certain development standards that apply to parcels greater than 30 acres. These
~` standards include such area as a small neighborhood park, garage placement, housing
mix, neighborhood center, and street connectivity. The L-M-N zone district is described
in the Land Use Code in Article Four, page 18.
5: Please note that the Land Use Code states that gated street entryways into residential
developments shall be prohibited.
6. The site will be served by the City of Fort Collins Light and Power Utility. The nearest
source of power is north of the Latimer and Weld Canal along the I-25 Frontage Road. In
order to bring power to the site, easements must be obtained from the intervening
property owners.
7. The developer's electrical contractor must complete the Commercial One ("C-1 ") Form to
determine entrance capacity. The clubhouse will need an electrical transformer. This
transformer must be accessible (within ten feet) to hard surface on one side for emergency
change -out. Also, the transformer must be screened with landscaping or by an enclosure.
The ultimate location of the transformer must be coordinated with Light and Power.
Normal development charges will apply. For further information, please contact Monica
Moore, 221-6700.
8. The site will be served water by the Easter Latimer County Water District (Elco). Please
contact Webb Jones for further information.
9. The site will be served sanitary sewer by Boxelder Sanitation District. Please contact
Dean Smith for firther information.
10. The site will be served by Poudre Fire Authority which requires that all exterior portions
of all buildings must be within 150 feet of an approved fire access lane. If some structures
are beyond 150 feet, then they must be equipped with an automatic fire extinguishing
system.
11. Poudre Fire Authority will also require that fire hydrants be spaced on 600 foot centers
and capable of delivering a minimum of 1,000 gallons per minute at 20 psi. This. pressure
must be confirmed by Elco.
12. The site is located in the Cooper SloughBoxelder Creek Drainage Basin. There is no
master drainage basin plan for this area because it is on the fringe of the city. For this
reason, there is no storm drainage fee in this basin at this time and there are no existing
drainage facilities to tie into.
13. The site is located very close to the Boxelder Creek 100-year floodplain. This is classified
as a "no -rise" floodplain which limits development potential. Please contact Marsha
Hilmes, Floodplain Administrator, 221-6589, for maps and further information regarding
regulations in the floodplain.
14. At the time of submittal, the P.D.P. must include a Drainage Report, Grading and
Drainage Plan, and Erosion Control Plan meeting the requirements of the Stormwater
Utility. Storm flows must be treated to improve downstream water quality. The best
management practice at this time is extended detention. The natural outf ill for storm
flows is Boxelder Creek. Offsite drainage easements are required in order to convey
storm flows across intervening property to get to Boxelder Creek. At the time of
submittal for a P.D.P., a "Letter of Intent" from intervening property owners allowing
storm flows to pass through their property must be delivered to the Planning Department.
For further information or to set up a pre -submittal meeting, please contact Glen
Schlueter, 221-6589.
15. Each dwelling unit will be assessed a Neighborhood Parkland Fee. This fee is based on
square footage of the unit-. There are five categories ranging from $495 for -units under
700 square feet to $1,19.1 for units over 2,201 square feet. These fees are adjusted
annually. Please contact Janet Meisel for an estimate of this fee based on unit size.
16. Each dwelling unit will be assessed the Residential Capital Expansion Fee. This fee is for
library, community parkland, police, fire, and general governmental services capital needs.
This fee ranges from $888 for units under 700 square feet to $2,131 for units over 2,201
square feet. These fees are adjusted annually. Please contact Carol Goff; 221-6760, for
an estimate of this fee based on unit size.
17. Please keep in mind that the L-M-N rauirement for a small neighborhood park requires
that it be at least one acre in size and shall be located within a maximum of one-third mile
of at least 900/6 of the dwellings in the P.D.P. as measured along street frontage. Although
the Code indicates that this park may be public or private, please be aware that the site is
too remotely located on the city's fringe to qualify for a public park. There are other
requirements for this park as stated in Article Four, page 27 of the Land Use Code.
18. Each dwelling unit will be assessed a Street Oversizing Fee. For duplexes, this fee is
estimated to be $1,021 per unit. For an accurate estimate based on unit size and trip
generation, please contact Matt Baker, 221-6W5.
19. A Traffic Impact Study (T.I.S.) will be required, This study must address all modes of
travel including bicycle, pedestrian, and transit. In order to determine the scope of the
T.I.S., please contact Eric Bracke, 221-6630.
20. Please be aware that the Land Use Code requires that development on the fringe improve
the adjacent arterial street back to the nearest fully improved arterial. In this case, this
would be the intersection of East Vine Drive and Summitview. (The project must be
evaluated on its own in case Waterglen P.U.D. does not develop.)
21. Please be aware that the City and Colorado Department of Transportation (CDOT) are
investigating a northeast truck bypass to connect I-25 to Ii'ighway 297. This may or may
not include improving the I-25/East. Vine interchange. In either case, however, it is likely
that right-of-way may be required along I-25 and East Vine for such improvements. This
dedication, however, may be tied to development on the western portion of the property
and not necessarily tied to the request for residential on the east portion. For further
information on the truck bypass study, please call Eric Bracke, 221-6630.
22. In the northeast portion of the property, the development appears to come in close
proximity to Boxelder Creek. Please be aware that there must be a minimum of 100 feet
between the limits of development and the wedand/riparian zone of Boxelder Creek. For
further -information, please refer to Section 3.4 (Article Three, pages 56-72) of the Land
Use Code. Also, please contact Rob Wilkinson, 221-6750, if you have any questions
regarding natural resource protection.