Loading...
HomeMy WebLinkAboutNORTH LEMAY PLAZA PUD - FINAL - 57-87A - CORRESPONDENCE - HAZMATS (2)CAN GEFROH HATTIVIAIV INC: ARCHITECTS/PLANNERS CONSTRUCTION MANAGEMENT 135 West Swallow Road Fort Collins, CO 80525 January 13, 1988 (303) 223-7335 Mr. Dave Sawyer POUDRE VALLEY FIRE DEPARTMENT 505 Peterson Avenue Fort Collins, CO 80521 RE: UNDERGROUND STORAGE TANK INSTALLATION NORTH LEMAY.PLAZA FORT COLLINS, COLORADO Dear Mr. Sawyer: The North Lemay Plaza is a P.U.D. that has been submitted to the City for final review. A part of this P.U.D. is.a convenience center which will have fuel filling center. The City has requested that you review the outlined specifications for tank installation for this property. The main concern appears to be with potential groundwater contamination from tank leakage. As you are aware, State and Federal regulations govern the installation of these types of installations. It is the Intent of the Developer and the Tenant/Operator to follow all applicable regulations for fuel storage tank installations. It will be the Tenant, P.D.Q.'s responsibility for the installation of these facl- ities and for on -going maintenance. Currently a 'soils' investigation has been performed by Empire Labs of Fort Collihls for the site outlining soil and groundwater conditions that exist on site. These recommendations will be followed in preparing site and installing the tanks. I am including along with the outline specifications a copy of the soils' re- port and a site plan showing.the tank locations. As you will note, the tanks are placed on a virtually level portion .of the site more than 65 feet from the irrigation canal to the South of the site which is noted as potentially unstable ground in the §oils' f8 port. If ybd kavG 66y questions; please give me a call. Slfit0_ V8§ F edric J at man Vice President kam 3 enc. NORTH LEMAY PLAZA OUTLINE SPECIFICATION UNDERGROUND STORAGE TANK GENERAL: Provide installation of fiberglass petroleum storage tank to all current applicable standards. STANDARD: State of Colorado for underground storage of hazardous materials. Uniform Fire Code. OSHA.. CONCRETE FILL MATERIAL: 3000 PSI, after 28 days, 4 sack mix of wash- ed fine grained granular or crushed.aggregate. TANK: Fiberglass reinforced resin, Class 200. EXPERIENCE: Installer with minimum of 5 years experience.in installing petroleum underground tanks. INSTALLATION: Provide.temporary dewatering of site throughout installa- tion of tanks adequate to maintain excavation dry. Tank to be anchored positively to stread footing by concrete saddle and concrete cradle ar- rangement at point designed by tank manufacturer. Backfill excavation with granular fill. Compact adjacent to tank compact to 80% ASTM 4253-83. Compact 24" from surface cover to 95% standard proctor density. Top 6" of cover to be continuously poured concrete slab.