Loading...
HomeMy WebLinkAboutKUM & GO #0951 - PDP210013 - DOCUMENT MARKUPS - ROUND 4 - UTILITY PLANS (3)PROJECTLOCATIONE. PROSPECT RDSHEET NUMBER:CPM: SDM: RDM:08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT 1459 Grand AvenueDes Moines, Iowa50309P: 515-226-0128F: 515-223-9873DATE:TCDGBSCALL 811 SEVENTY-TWO HOURS PRIOR TODIGGING, GRADING OR EXCAVATING FOR THEMARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013 Know what'sbelow.before you dig.CallRwww.olsson.comTEL 303.237.2072 1525 Raleigh St. Suite 400 Denver, CO 80204 DATE REVISION DESCRIPTION OF 37VICINITY MAPBENCHMARKSNGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88)CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88)BENCHMARKS:BASIS OF BEARINGS:ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, ASMONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND ACONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56"EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRALZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGSCONTAINED HEREIN RELATIVE THERETO.FLOOD ZONE:X, AREA OF MINIMAL FLOOD HAZARD AND SPECIAL FLOOD HAZARD AREA, FLOOD ZONE AE WITHBFE (BASE FLOOD ELEVATION) OR DEPTH DETERMINED, PER FEMA FLOOD MAP 08069C0983HEFFECTIVE MAY 02, 2012PROJECT TEAM:AGENCY CONTACTS:OWNER/DEVELOPER/APPLICANT:ENGINEER:LANDSCAPE ARCHITECT:GEOTECHNICAL ENGINEER:SURVEYOR:SANITARY SEWER:TELEPHONE:GAS:ACCESS AND ROADHEALTH DEPARTMENT:FIRE DEPARTMENT:ELECTRIC:BUILDING PERMIT:WATER:STORM SEWER:PLANNING DEPARTMENT:LOT 5 SITE DATASTORE TYPEMARKETPLACE BISTROCANOPY / DISPENSER ARRANGEMENT4 DISPENSERS(SINGLE)TYPE OF USECONVENIENCE STOREWITH FUELHEIGHTBUILDINGPARAPET1/3 OF SUPPORTINGWALL HEIGHTBLADEFUEL CANOPYGROSS FLOOR AREA3,946 SFGROSS CANOPY AREA2,592 SFGROSS LOT AREA40,012 SF 0.919 ACBUILDING COVERAGE3,946 SF (9.9%)LANDSCAPE COVERAGE9,971 (24.9%)PARKING/DRIVE/SIDEWALK COVERAGE26,095 SF (65.2%)BICYCLE PARKING2 SPACESTOTAL EMPLOYEES16-18EMPLOYEES PER SHIFT3-5REQUIRED PARKINGSTANDARD8 MIN - 16 MAXADA1TOTAL8 MIN - 16 MAXPARKING RATIO = 1 STALL/200 SFPROVIDED PARKINGSTANDARD15ADA1TOTAL16PARKING RATIO = 1 STALL/247 SFZONING INFORMATIONCURRENT: NEIGHBORHOOD COMMERCIAL DISTRICT (N-C)MINIMUM LOT AREAMINIMUM LOT WIDTHSITE AREA PER UNITFRONT YARD SETBACK NORTH (FEET)LEFT SIDE YARD SETBACK WEST (FEET)RIGHT SIDE YARD SETBACK EAST (FEET)REAR YARD SETBACK SOUTH (FEET)MAXIMUM HEIGHT (FEET)MAXIMUM BUILDING COVERAGE (SF)MAXIMUM IMPERVIOUS COVERAGEFLOOR AREA RATIOCONFIDENTIAL DOCUMENT:INFORMATION CONTAINED IN THIS DOCUMENT ISPROPRIETARY TO KUM & GO, L.C. AND SHALL NOTBE DISTRIBUTED.C0.0COVER SHEET E. PROSPECT RDS. LEMAY AVE WHERE & MEANS MORE.1UTILITY PLANS FORSTORE #0951LOT 5, EAST ACRES949 E. PROSPECT ROAD FORT COLLINS, COLEGAL DESCRIPTION:LOT 5, EAST ACRES, BEING A PORTION OF THE NORTHEAST QUARTER OF SECTION 24, TOWNSHIP 7NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OFCOLORADO"I hereby affirm that these final construction plans wereprepared under my supervision, in accordance with allapplicable City of Fort Collins and State of ColoradoStandards and statutes, respectively; and that I am fullyresponsible for the accuracy of all design, revisions, andrecord conditions that I noted on these plans."DateEngineerThese plans have been reviewed by the Local Entity forconcept only. The review does not imply responsibility bythe reviewing department, the Local Entity Engineer, orthe Local Entity for accuracy and correctness of thecalculations. Furthermore, the review does not imply thatquantities of items on the plans are the final quantitiesrequired. The review shall not be construed in any reasonas acceptance of financial responsibility by the LocalEntity for additional quantities of items shown that may berequired during the construction phase.REFERENCE REPORT OF GEOTECHNICAL EXPLORATION PREPARED BY OLSSON ON 6/24/2021City of Fort Collins, ColoradoUTILITY PLAN APPROVALAPPROVED:APPROVED:APPROVED:APPROVED:APPROVED:APPROVED:Approved SheetsApproved SheetsApproved SheetsApproved SheetsApproved SheetsApproved SheetsDateDateDateDateDateDateEnvironmental Planner,Traffic Operations,Park Planning and Development,Stormwater Utility,Water & Wastewater Utility,City Engineer,FLOOD ZONE NOTE:DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAYALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTIONACTIVITY (CURB & GUTTER, PAVEMENT, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKINGLOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE SPRINGCREEK FLOOD PLAIN LIMITS AS DELINEATED ON FINAL DEVELOPMENT DOCUMENTS. ALL ACTIVITIESWITHIN THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORTCOLLINS MUNICIPAL CODE.SHEET INDEXSheet N u m be r Sheet Titl e1C0.0COVER SHEET2C0.1GENERAL NOTES3C0.2CITY GENERAL NOTES4C0.3EXISTING CONDITIONS5C0.4EXISTING CONDITIONS6C0.5DEMOLITION PLAN7C1.0PROJECT PLAN8C2.1GRADING PLAN9C2.2DETAILED GRADING PLAN10C2.3DRAINAGE PLAN11C2.4DRAINAGE DETAILS12C2.5DRAINAGE DETAILS13C2.6DRAINAGE DETAILS14C2.7PH. 1 EROSION CONTROL PLAN15C2.8PH. 2 EROSION CONTROL PLAN16C2.9PH. 3 & 4 EROSION CONTROL PLAN17C2.10STD. EROSION CONTROL NOTES18C2.11EROSION CONTROL DETAILS19C2.12EROSION CONTROL DETAILS20C3.1UTILITY SERVICE PLAN21C3.2UTILITY DETAILS22C3.3UTILITY DETAILS23C4.1HORIZONTAL CONTROL PLAN24C4.2DETAILED HORIZONTAL CONTROLPLAN25C4.3HORIZONTAL CONTROL POINTTABLES26C4.4FLOWLINE PLAN & PROFILE27C4.5SIGNAGE AND STRIPING PLAN28C4.6ADA PLAN29C4.7PAVING DETAILS30C4.8PAVING DETAILS31C4.9PAVING DETAILS32C4.10SIGNAGE & SITE DETAILS33C5.0TRAFFIC SIGNAL PLAN34I1.1FINAL IRRIGATION PLAN35I1.2IRRIGATION DETAILS 136I1.3IRRIGATION DETAILS 23608/15/2022 SHEET NUMBER:CPM: SDM: RDM:08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT 1459 Grand AvenueDes Moines, Iowa50309P: 515-226-0128F: 515-223-9873DATE:TCDGBSCALL 811 SEVENTY-TWO HOURS PRIOR TODIGGING, GRADING OR EXCAVATING FOR THEMARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013 Know what'sbelow.before you dig.CallRwww.olsson.comTEL 303.237.2072 1525 Raleigh St. Suite 400 Denver, CO 80204 DATE REVISION DESCRIPTION OF 37CONFIDENTIAL DOCUMENT:INFORMATION CONTAINED IN THIS DOCUMENT ISPROPRIETARY TO KUM & GO, L.C. AND SHALL NOTBE DISTRIBUTED.GENERAL NOTES1.ALL WORK AND CONSTRUCTION OF THIS PROJECT ON PRIVATE PROPERTY SHALL CONFORM TO KUM & GOSTANDARD SPECIFICATIONS, CITY OF FORT COLLINS, CDOT, AND THE SPECIFICATIONS/DETAILS SHOWN ONTHESE PLANS.2.ALL WORK AND CONSTRUCTION WITHIN PUBLIC RIGHT OF WAY AND EASEMENTS SHALL CONFORM TO THETECHNICAL SPECIFICATIONS, STANDARD DETAILS, AND DESIGN CRITERIA FOR PUBLIC IMPROVEMENTPROJECTS OF THE CITY OF FORT COLLINS, COUNTY OF LARIMER, CDOT, AND THE GRANTOR OF THEEASEMENT AS APPLICABLE.3.IN CASE OF A CONFLICT BETWEEN VARYING SPECIFICATIONS, THE MOST STRINGENT SHALL APPLY.4.THE CONTRACTOR SHALL OBTAIN A COPY OF THE LATEST STANDARD SPECIFICATIONS AND DETAILS OF ALLAGENCIES EXERCISING JURISDICTION OVER THIS PROJECT, WHICH ARE INCORPORATED BY REFERENCE ONTHESE PLANS. A COPY OF THESE SPECIFICATIONS AND DETAILS SHALL BE MAINTAINED ON THE JOBSITE ATALL TIMES.5.THE CONTRACTOR SHALL HAVE IN HIS POSSESSION AT ALL TIMES ONE (1) SIGNED COPY OF THE PLANS,STANDARDS, AND SPECIFICATIONS AS APPROVED BY THE APPROPRIATE GOVERNING AGENCY AND OWNER.THE CONTRACTOR SHALL NOT CHANGE OR DEVIATE FROM THESE PLANS WITHOUT FIRST OBTAININGWRITTEN APPROVAL FROM THE OWNER, ENGINEER, AND GOVERNING AGENCY.6.ALL WORK SHALL CONFORM TO ALL LOCAL, STATE, AND FEDERAL APPLICABLE LAWS AND REGULATIONS.7.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB SITE SAFETY ON THE PROJECT. THIS SHALLINCLUDE THE SAFETY OF HIS OWN PERSONNEL, SUBCONTRACTORS, ALL VISITORS TO THE SITE, AND THEGENERAL PUBLIC. ALL JOB SITE SAFETY SHALL COMPLY WITH ALL LOCAL, STATE, AND FEDERALREGULATIONS AND CODES, AND ENSURE COMPLIANCE INCLUDING, BUT NOT LIMITED TO, THE OCCUPATIONALSAFETY AND HEALTH ADMINISTRATION (OSHA) REQUIREMENTS.8.THE CONTRACTOR SHALL CONTACT ONE CALL OF COLORADO AT #811 OR 1-800-922-1987 A MINIMUM OF 72HOURS (EXCLUDING WEEKENDS AND HOLIDAYS) IN ADVANCE OF ANY EXCAVATION.9.THE LOCATIONS OF EXISTING UTILITIES AND STRUCTURES SHOWN ON THE PLANS ARE APPROXIMATE ANDHAVE BEEN SHOWN FROM AVAILABLE SURVEYS AND/OR RECORDS. THERE MAY BE ADDITIONAL UTILITIESPRESENT, THE EXISTENCE OF WHICH IS NOT PRESENTLY KNOWN OR SHOWN. IT IS THE CONTRACTOR'SRESPONSIBILITY TO DETERMINE THEIR EXISTENCE, EXACT LOCATION/SIZE, ADEQUATELY PROTECT/SUPPORT,AND TO AVOID DAMAGE THERETO. THE CONTRACTOR SHALL INCLUDE, AT NO ADDITIONAL COST, ANYPOTHOLING OR EXPLORATORY EXCAVATIONS NECESSARY TO LOCATE EXISTING UTILITIES. UTILITIES SHALLBE LOCATED SUFFICIENTLY AHEAD OF CONSTRUCTION TO PERMIT REVISIONS TO PLANS IF REVISIONS ARENECESSARY DUE TO ACTUAL LOCATION OF EXISTING FACILITIES. DAMAGE TO UTILITIES AND STRUCTURESSHALL BE REPAIRED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THEGOVERNING AGENCY AND/OR THE UTILITY OWNER.10.ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE INDICATED IN THE PLANS, AND SHALL BE SUBJECT TOINSPECTION AND APPROVAL BY THE OWNER OR THE OWNER'S REPRESENTATIVE.11.LOCATIONS AND ELEVATIONS OF EXISTING IMPROVEMENTS TO BE MET (OR AVOIDED) BY THE PROPOSEDWORK SHALL BE CONFIRMED BY THE CONTRACTOR THROUGH FIELD EXPLORATIONS PRIOR TOCONSTRUCTION. CONTRACTOR SHALL REPORT TO THE OWNER ANY DISCREPANCIES BETWEEN HISMEASUREMENTS AND THESE PLANS.12.THE CONTRACTOR SHALL CONTACT THE OWNER IMMEDIATELY UPON DISCOVERY OF ANY ERRORS ORINCONSISTENCIES SHOWN IN THE PLANS AND/OR SPECIFICATIONS. DO NOT SCALE DRAWINGS - USE ONLYDIMENSIONS PROVIDED ON THESE PLANS.13.ALL ESTIMATES OF QUANTITIES ARE FOR INFORMATIONAL PURPOSES ONLY. CONTRACTOR ANDSUBCONTRACTORS SHALL BE RESPONSIBLE FOR DETERMINING ACTUAL QUANTITIES, AND SHALL PROVIDEALL WORK AND MATERIALS NECESSARY TO CONSTRUCT THE PROJECT IN ITS ENTIRETY.14.CONTRACTOR SHALL PROTECT ALL EXISTING IMPROVEMENTS NOT DESIGNATED FOR REMOVAL AND THOSEIMPROVEMENTS THAT ARE OUTSIDE THE LIMITS OF THE PROPOSED CONSTRUCTION. CONTRACTOR SHALLTAKE CARE TO AVOID DAMAGE THERETO AND SHALL PROVIDE TEMPORARY FENCING, BARRICADES,SUPPORTS, RESTRAINTS, AND/OR BRACING WHERE REQUIRED TO PROTECT EXISTING IMPROVEMENTS.DAMAGE TO EXISTING IMPROVEMENTS SHALL BE REPAIRED AND/OR REPLACED TO EQUAL OR BETTERCONDITION AT THE CONTRACTOR'S EXPENSE.15.ALL GRADING AND CONSTRUCTION ACTIVITIES SHALL BE CONFINED TO THE OWNER'S PROPERTY, PUBLICRIGHT-OF-WAY, PERMANENT EASEMENTS, AND TEMPORARY CONSTRUCTION EASEMENTS.16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS NOT OBTAINED BY THE OWNER OROWNER'S REPRESENTATIVES, AND PAY ALL FEES AS REQUIRED BY THE CONSTRUCTION COVERED IN THESEPLANS.17.THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING THE APPROPRIATE GOVERNING AGENCIES ANDLOCAL FIRE DEPARTMENT OF ALL STREET CLOSURES AND EXISTING FIRE HYDRANTS/FIRE SUPPRESSIONTAKEN OUT OF SERVICE AT LEAST 48 HOURS PRIOR TO CONSTRUCTION.18.THE CONTRACTOR IS RESPONSIBLE FOR ALL SITE SECURITY AND SHALL PROPERLY PROTECT ANDBARRICADE THE CONSTRUCTION SITE UNTIL CONSTRUCTION IS COMPLETE. STORAGE, LOSS DUE TO THEFT,OR VANDALISM OF MATERIALS AND EQUIPMENT (SECURED OR UNSECURED) WILL BE SOLELY AT THECONTRACTOR'S EXPENSE.19.PRIOR TO BEGINNING THE WORK, THE CONTRACTOR SHALL OBTAIN ANY WRITTEN AGREEMENTS FORINGRESS AND EGRESS TO THE WORK FROM ADJACENT PRIVATE PROPERTY OWNERS. ACCESS TO ANYADJACENT PRIVATE PROPERTY SHALL BE MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD, DURINGALL HOURS OF OPERATION FOR THE BUSINESS LOCATED ON THOSE PARCELS.20.FOR ANY CHANGES OR DEVIATIONS FROM THESE PLANS PROPOSED BY THE CONTRACTOR, SHOP DRAWINGSAND MATERIAL SPECIFICATIONS SHALL BE SUBMITTED TO OWNER FOR REVIEW AND APPROVAL PRIOR TOPLACEMENT OF MATERIAL.21.CONTRACTOR MUST COORDINATE ALL CONSTRUCTION WITH THE DESIGNATED KUM & GO CONSTRUCTIONPROJECT MANAGER.22.CONTRACTOR SHALL PROTECT AND PRESERVE ALL SURVEY CONTROL AND PROPERTY MONUMENTATION.ANY DAMAGED MONUMENTS SHALL BE RESET BY A PROFESSIONAL LAND SURVEYOR LICENSED IN THEPROJECT'S STATE AT THE CONTRACTOR'S EXPENSE.23.PRIOR TO MOVING OFF THE JOB SITE THE CONTRACTOR SHALL NOTIFY THE OWNER OR THE OWNER'SREPRESENTATIVE TO PERFORM THE FINAL WALK-THROUGH OF THE CONSTRUCTION SITE.24.TEMPORARY POWER, TELEPHONE, AND WATER FOR THE SITE IS THE CONTRACTOR'S RESPONSIBILITYUNLESS OTHERWISE SPECIFIED.25.CONTRACTOR SHALL REFER TO OTHER DRAWINGS ISSUED BY ARCHITECT, STRUCTURAL, ELECTRICAL, ANDMECHANICAL ENGINEERS. ENSURE COORDINATION OF EXACT LOCATION AND DIMENSIONS OF BUILDINGS,EXITS, RAMPS, UTILITY ENTRANCE LOCATIONS AND GRADES AROUND THE BUILDING. IMMEDIATELY NOTIFYOWNER OF ANY DISCREPANCIES.26.NO BELOW GRADE WORK SHALL BE BACKFILLED (INCLUDING BEDDING MATERIAL ABOVE THE SPRING LINE OFTHE PIPE) UNTIL THE CONSTRUCTION HAS BEEN INSPECTED AND APPROVED FOR BACKFILLING BY THEAPPROPRIATE GOVERNING AGENCY, OWNER AND/OR OWNER'S REPRESENTATIVE.27.THE CONTRACTOR SHALL PROVIDE ALL TRAFFIC CONTROL NECESSARY TO COMPLETE THE WORK. ALLTRAFFIC CONTROL DEVICES AND METHODS OF CONTROLLING TRAFFIC THROUGH CONSTRUCTION ZONESSHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MUTCD, AND ALL REVISIONS THERETOINCLUDING LOCAL AND STATE SUPPLEMENTS. ADDITIONAL WORK IN THE RIGHT-OF-WAY OR TRAFFICCONTROL PERMITS MAY BE NECESSARY AND SHALL BE THE CONTRACTOR'S RESPONSIBILITY.28.IF UNANTICIPATED HAZARDOUS MATERIALS OF ANY KIND ARE ENCOUNTERED IN THE WORK, THECONTRACTOR SHALL IMMEDIATELY CEASE ALL CONSTRUCTION OPERATIONS AND NOTIFY THE OWNERAND/OR OWNER'S REPRESENTATIVE FOR FURTHER DIRECTION.29.ALL DEBRIS RESULTING FROM CONSTRUCTION AND DEMOLITION SHALL BE HAULED OFF SITE AND DISPOSEDOF PROPERLY AND LEGALLY.30.GENERAL CONTRACTOR SHALL COORDINATE WITH POSTMASTER TO DETERMINE MAILBOX LOCATION.SITE PLAN NOTES1.DIMENSIONS SHOWN ON THE SITE PLAN ARE TO FACE OF CURB LINE IN CURBED AREAS AND EXTERIOR FACEOF BUILDING, UNLESS OTHERWISE SPECIFIED.2.A SEPARATE SIGN APPLICATION TO THE CITY OF FORT COLLINS IS REQUIRED FOR ALL SIGNS.DEMOLITION PLAN NOTES1.PRIOR TO BIDDING, CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH THE EXISTINGCONDITIONS OF THE PROJECT AREA AND ANTICIPATED DEMOLITION REQUIREMENTS.2.CONTRACTOR TO PROTECT ALL UTILITY, PAVING, BUILDINGS, ETC. OUTSIDE OF LIMITS OF PROPOSEDCONSTRUCTION DURING DEMOLITION OPERATIONS.3.ALL EXISTING PAVEMENT ONSITE SHALL BE REMOVED UNLESS OTHERWISE NOTED.4.CONTRACTOR SHALL REFER TO PAVING PLAN FOR DETAILS ON LIMITS OF PAVING DEMOLITION, AND EROSIONCONTROL PLAN FOR PERIMETER CONTROL.5.ALL DEMOLITION WORK ON THIS CONSTRUCTION SITE SHALL BE IN CONFORMANCE WITH LOCAL STANDARDSAND GUIDELINES.6.THIS DEMOLITION PLAN DEPICTS THE ANTICIPATED REMOVALS NECESSARY FOR CONSTRUCTION OF THEPROJECT. MISCELLANEOUS AND MINOR REMOVALS MAY NOT BE SHOWN IN DETAIL BUT ARE CONSIDEREDOBLIGATORY TO THE PROJECT. ADDITIONAL REMOVALS MAY BE NECESSARY AND THE CONTRACTOR WILL BEREQUIRED TO REMOVE ALL EXISTING IMPROVEMENTS THAT ARE IN CONFLICT WITH THE PROPOSEDCONSTRUCTION AND AS OTHERWISE DIRECTED BY THE OWNER.7.CONTRACTOR SHALL COORDINATE DEMOLITION AND/OR RELOCATION OF EXISTING UTILITIES WITH THEAPPROPRIATE UTILITY OWNER AND IN ACCORDANCE WITH THE UTILITY OWNER'S REQUIREMENTS.INTERRUPTIONS IN SERVICE SHALL BE COORDINATED WITH THE UTILITY OWNER AND PROPERTY OWNER(S)IMPACTED. CONTRACTOR SHALL COORDINATE WITH THE RESPECTIVE UTILITY COMPANY FOR PORTIONS OFTHE WORK TO BE PERFORMED BY UTILITY COMPANY'S FORCES, AND PROVIDE ADEQUATE NOTICE FORSCHEDULING. THE CONTRACTOR IS RESPONSIBLE FOR PAYING ALL FEES AND CHARGES, UNLESSOTHERWISE PAID BY KUM & GO PRIOR TO CONSTRUCTION. UTILITY REMOVAL TRENCHES SHALL BEBACKFILLED WITH APPROVED MATERIAL AND MEET COMPACTION REQUIREMENTS PER THE GEOTECHNICALREPORT.8.THE SITE MAY CONTAIN EXISTING FOOTINGS OR OTHER UNDERGROUND STRUCTURES THAT ARE NOTDEPICTED ON THIS PLAN. CONTRACTOR SHALL TAKE CARE TO REMOVE ALL NECESSARY STRUCTURES ANDBACKFILL IN CONFORMANCE WITH THE GEOTECHNICAL REPORT. BOTTOM OF EXCAVATION SUBGRADE SHALLBE INSPECTED BY THE GEOTECHNICAL TESTING ENGINEER AND APPROVED PRIOR TO ANY BACKFILL.9.CONTRACTOR TO COMPLETELY REMOVE TREES DESIGNATED TO BE REMOVED, STUMPS, AND ROOTSYSTEMS.10.PRIOR TO DEMOLITION WORK, EROSION CONTROL DEVICES ARE TO BE INSTALLED. EROSION CONTROLMEASURES SHALL BE ADJUSTED AS DEMOLITION AND CONSTRUCTION SEQUENCING WARRANTS.11.ALL EXISTING UNUSED SERVICE LINES FOR WATER AND WASTEWATER SHALL BE REMOVED PER LOCALUTILITY COMPANY STANDARDS. ALL EXISTING UNUSED GAS, TELEPHONE, FIBER OR ELECTRIC LINE/SERVICESHALL BE COORDINATED FOR REMOVAL WITH UTILITY COMPANY.12.THE CONTRACTOR IS RESPONSIBLE FOR DEMOLITION, REMOVAL, AND DISPOSING IN A MANNER APPROVED BYALL GOVERNING AUTHORITIES FOR ALL STRUCTURES, PADS, WALLS, PANS, FOUNDATIONS, PAVEMENT,UTILITIES, ETC. TO BE DEMOLISHED, SUCH THAT THE IMPROVEMENTS SHOWN ON THE PLANS CAN BECONSTRUCTED. DEMOLITION AND DISPOSAL PERMITS SHALL BE THE CONTRACTOR'S RESPONSIBILITY. ALLFACILITIES TO BE REMOVED SHALL BE UNDERCUT TO APPROVED GRADE AND BROUGHT UP TO PROPOSEDGRADE WITH SUITABLE COMPACTED FILL MATERIAL PER THE GEOTECHNICAL REPORT.13.DURING DEMOLITION OPERATIONS, THE CONTRACTOR MUST PROTECT THE PUBLIC AT ALL TIMES USINGMEANS OF THEIR CHOICE.14.CONTRACTOR SHALL PRESERVE ALL LANDSCAPING NOT TO BE REMOVED FOR CONSTRUCTION. CONTRACTORSHALL BE RESPONSIBLE FOR RESTORING ALL AREAS DISTURBED BY CONSTRUCTION.15.SAWCUTS SHALL BE TO FULL DEPTH OF EXISTING PAVEMENT. CONCRETE PAVEMENT SHALL BE REMOVED TONEAREST EXISTING JOINT WHEN LESS THAN 5' FROM PROPOSED SAWCUT.GRADING PLAN NOTES1.PRIOR TO ANY GRADING OPERATIONS, ALL EROSION AND SEDIMENT CONTROL DEVICES SHALL BEADEQUATELY IN PLACE. REFER TO THE EROSION AND SEDIMENT CONTROL PLAN FOR REQUIREMENTS.2.THE CONTOUR LINES, SPOT ELEVATIONS AND BUILDING FLOOR ELEVATIONS SHOWN ARE TO FINISH GRADEFOR SURFACE OF PAVEMENT, TOP OF SIDEWALKS AND CURBS, TOP OF FLOOR SLABS, ETC. REFER TOTYPICAL SECTIONS FOR MULCH, SOD, PAVING, SLAB AND AGGREGATE BASE THICKNESS TO DEDUCT FORSUBGRADE ELEVATIONS.3.ALL TOP OF CURB AND SIDEWALK ELEVATIONS SHALL BE 0.5' ABOVE GUTTER ELEVATIONS UNLESSOTHERWISE NOTED. IN AREAS WITH SIDEWALK ABUTTING BACK OF CURB, TOP OF CURB ELEVATIONS SHALLBE EQUAL TO SIDEWALK ELEVATIONS.4.THE CONTRACTOR SHALL FINISH GRADE SLOPES AS SHOWN NO STEEPER THAN ONE FOOT VERTICAL INTHREE FEET HORIZONTAL.5.CONTRACTOR SHALL GRADE LANDSCAPED AREAS TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGSAND SIDEWALKS WHEN FINISH LANDSCAPE MATERIALS ARE IN PLACE. SLOPE SHALL BE A 2% MINIMUM.6.SITE AND BUILDING PAD PREPARATION, GRADING AND EXCAVATION PROCEDURES SHALL CONFORM TO THERECOMMENDATIONS OUTLINED IN THE REPORT OF GEOTECHNICAL EXPLORATION PREPARED BY OLSSON,PROJ. NO. 020-2883.7.IN CASE OF ANY DISCREPANCIES REGARDING EARTHWORK BETWEEN THE REPORT OF GEOTECHNICALEXPLORATION AND THE SPECIFICATIONS SHOWN IN THESE PLANS, NOTIFY THE OWNER IMMEDIATELY.8.ALL HERBACEOUS VEGETATION AND TOPSOIL SHALL BE STRIPPED TO A MINIMUM DEPTH OF 6" (IFENCOUNTERED) AND REMOVED FROM SITE OR STOCKPILED FOR LATER USE IN LANDSCAPED AREAS.9.ALL EXISTING PAVEMENT, UTILITIES, BURIED DEBRIS, RUBBLE, AND/OR STRUCTURES/FOUNDATIONSENCOUNTERED WITHIN AREAS OF DISTURBANCE SHALL BE COMPLETELY REMOVED PRIOR TO OR DURINGEARTHWORK OPERATIONS. WASTED MATERIAL SHALL NOT BE BURIED ONSITE WITHOUT THE PRIORAPPROVAL OF THE OWNER.10.THE AREA ABOVE THE SPRINGLINE OF ALL UTILITY TRENCHES IN UNPAVED AREAS SHALL BE BACKFILLEDWITH COMPACTED COHESIVE SOILS. SEE REPORT OF GEOTECHNICAL EXPLORATION FOR COMPACTION ANDMOISTURE RECOMMENDATIONS.11.FINAL PAVEMENT SUBGRADES SHALL BE PROOFROLLED IMMEDIATELY PRIOR TO THE PLACEMENT OF THEPAVEMENT TO DETECT LOCALIZED AREAS OF INSTABILITY. PROOFROLLING IS NOT RECOMMENDED IN THEAREAS OF THE NEW FUEL TANKS OR DELIVERY LINE INSTALLATION.12.SUITABLE FILL MATERIALS SHALL BE PLACED IN THIN LIFTS OF 4 TO 8 INCHES LOOSE MEASUREMENT, UNLESSOTHERWISE ALLOWED IN THE REPORT OF GEOTECHNICAL EXPLORATION.13.IF REQUIRED, THE CONTRACTOR SHALL OBTAIN ALL LOCAL AND STATE PERMITS AND AUTHORIZATION TODISCHARGE FROM DEWATERING ACTIVITIES.14.THE CONTRACTOR SHALL DEWATER ALL EXCAVATIONS AND TRENCHES AS NEEDED FOR THE CONSTRUCTIONOF THE PROJECT USING MEANS/METHODS OF HIS CHOICE. REFER TO THE REPORT OF GEOTECHNICALEXPLORATION FOR ANTICIPATED LEVELS OF GROUNDWATER AND DEWATERING RECOMMENDATIONS.15.ALL EXCAVATIONS AND TRENCHES SHALL BE SLOPED/SHORED/BRACED FOR PROTECTION OF PERSONNEL INACCORDANCE WITH OSHA REGULATIONS AND AT THE CONTRACTOR'S FULL DISCRETION BASED ON THE SITECONDITIONS. OPEN EXCAVATIONS SHALL BE ADEQUATELY PROTECTED AND/OR FENCED AS NECESSARY ANDFOR THE SAFETY OF THE PUBLIC.STORMWATER MANAGEMENT AND EROSION/SEDIMENT CONTROL NOTES1.THIS PROJECT REQUIRES A PERMIT FOR STORMWATER DISCHARGE ASSOCIATED WITH CONSTRUCTIONACTIVITY FROM THE STATE'S GOVERNING AUTHORITY. CONTRACTOR TO COMMENCE WORK ON THIS SITEONLY AFTER AN ACTIVE PERMIT NUMBER HAS BEEN OBTAINED FROM THE STATE'S GOVERNING AUTHORITY.A LOCAL CONSTRUCTION STORMWATER PERMIT IS ALSO REQUIRED BY THE CITY OF FORT COLLINS.2.THE CONTRACTOR SHALL CONTINUOUSLY PROVIDE ADEQUATE STORMWATER MANAGEMENT INACCORDANCE WITH THE APPROVED STORMWATER MANAGEMENT PLAN (SWMP).3.THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE PUBLIC STREETS, ACCESS ROUTES, ANDWATERWAYS IN THE VICINITY OF THE JOB SITE CLEAN AND FREE OF ROCKS, SOIL AND DEBRIS.4.THE CONTRACTOR SHALL INSTALL EROSION AND SEDIMENTATION CONTROL “BEST MANAGEMENT PRACTICES”(BMPS) PRIOR TO ANY SITE PREPARATION WORK (E.G., CLEARING, GRUBBING, DEMOLITION, OR EXCAVATION).5.THE PLACEMENT OF EROSION AND SEDIMENT BMPS SHALL BE IN ACCORDANCE WITH THE EROSION ANDSEDIMENT CONTROL PLAN PREPARED FOR THE PROJECT. CONTRACTOR TO ADJUST QUANTITY, LOCATION,AND TYPE OF EROSION AND SEDIMENT CONTROL BMPS AS NECESSARY FOR THE VARIOUS PHASES OF THEWORK AND AS ACTUAL CONDITIONS WARRANT. CONTRACTOR SHALL CONTINUOUSLY MODIFY THE EROSIONAND SEDIMENT CONTROL PLAN WITH CURRENT BMPS IN ACCORDANCE WITH THE CONSTRUCTIONSTORMWATER PERMIT REQUIREMENTS. ADDITIONAL EROSION AND SEDIMENT CONTROL BMPS EMPLOYED BYTHE CONTRACTOR AT HIS DISCRETION WILL NOT BE MEASURED OR PAID FOR SEPARATELY BUT SHALL BEINCLUDED IN THE WORK.6.A GROUNDWATER DISCHARGE PERMIT MAY BE REQUIRED FROM THE STATE GOVERNING AUTHORITY PRIORTO DISCHARGE.7.GROUNDWATER SHALL BE SAMPLED AND SENT TO AN APPROVED LABORATORY FOR TESTING PRIOR TOBEING DISCHARGED. TESTING SHALL BE IN ACCORDANCE WITH THE PERMIT FOR STORMWATER DISCHARGE.8.APPROVED EROSION AND SEDIMENT CONTROL BMPS SHALL BE MAINTAINED AND KEPT IN GOOD REPAIR FORTHE DURATION OF THIS PROJECT. UNLESS OTHERWISE REQUIRED BY THE STATE'S CONSTRUCTIONSTORMWATER PERMIT, AT A MINIMUM THE CONTRACTOR SHALL INSPECT ALL BMPS EVERY 14 DAYS, ANDAFTER ALL SIGNIFICANT PRECIPITATION EVENTS I.E. RAINFALL, SNOWMELT. ALL NECESSARY MAINTENANCEAND REPAIR ACTIVITIES SHALL BE COMPLETED AS SOON AS POSSIBLE (IMMEDIATELY IN MOST CASES) AFTERDIRECTION BY THE INSPECTOR. ACCUMULATED SEDIMENT AND CONSTRUCTION DEBRIS SHALL BE REMOVEDWEEKLY FROM ALL BMPS, OR AT ANY TIME THAT SEDIMENT OR CONSTRUCTION DEBRIS ADVERSELY IMPACTSTHE FUNCTIONING OF THE BMPS.9.TOPSOIL AND SUITABLE EARTHEN MATERIALS SHALL BE SEGREGATED AND STOCKPILED WITHIN THE LIMITSOF CONSTRUCTION FOR USE ON AREAS TO BE FILLED AND RE-VEGETATED. ANY AND ALL STOCKPILES SHALLBE PLACED IN AN APPROVED LOCATION AND PROTECTED FROM EROSIVE ELEMENTS USING MEASURESSPECIFIED IN THE EROSION/SEDIMENT CONTROL PLAN AND STORMWATER MANAGEMENT PLAN (SWMP).10.SOILS THAT WILL BE STOCKPILED FOR MORE THAN THIRTY (30) DAYS SHALL BE MULCHED AND SEEDED WITHA TEMPORARY OR PERMANENT GRASS COVER WITHIN FOURTEEN (14) DAYS OF STOCKPILE CONSTRUCTION.11.ANY SETTLEMENT OR SOIL ACCUMULATIONS BEYOND THE LIMITS OF CONSTRUCTION DUE TO GRADING OREROSION SHALL BE REPAIRED IMMEDIATELY BY THE CONTRACTOR. THE CONTRACTOR SHALL BE HELDRESPONSIBLE FOR REMEDIATION OF ANY ADVERSE IMPACTS TO ADJACENT WATERWAYS, WETLANDS,PROPERTIES, ETC. RESULTING FROM WORK DONE AS PART OF THIS PROJECT.12.A WATER SOURCE MUST BE AVAILABLE ON SITE DURING EARTHWORK OPERATIONS AND UTILIZED ASREQUIRED TO MINIMIZE DUST FROM EARTHWORK EQUIPMENT AND WIND.13.THE CONTRACTOR MUST KEEP ALL POLLUTANTS, INCLUDING SEDIMENT, CONSTRUCTION DEBRIS, ANDTRENCH BACKFILL MATERIALS FROM ENTERING THE STORM SEWER SYSTEM.14.ALL SPILLS INCLUDING, BUT NOT LIMITED TO, PETROLEUM PRODUCTS, SOLVENTS, AND CEMENT SHALL BECLEANED UP IMMEDIATELY. THE LOCAL CITY/COUNTY AND STATE'S GOVERNING AUTHORITY SHALL BENOTIFIED IMMEDIATELY.15.THE CONTRACTOR SHALL ENSURE THAT ALL LOADS OF CUT AND FILL MATERIAL IMPORTED TO OR EXPORTEDFROM THE SITE SHALL BE PROPERLY COVERED TO PREVENT LOSS OF THE MATERIAL DURING TRANSPORT ONPUBLIC RIGHT-OF-WAY. ALL MATERIAL EXPORTED FROM THE SITE SHALL BE DISPOSED OF AT A SITEPERMITTED TO ACCEPT SUCH MATERIAL.16.THE USE OF REBAR, STEEL STAKES OR STEEL FENCE POSTS FOR STAKING DOWN STRAW OR HAY BALES, ORTO SUPPORT SILT FENCING USED AS AN EROSION CONTROL MEASURE, IS PROHIBITED.17.THE CLEANING OF CONCRETE DELIVERY TRUCK CHUTES IS RESTRICTED TO APPROVED LOCATIONS ON THEJOB SITE. THE DISCHARGE OF WATER CONTAINING WASTE CEMENT TO THE STORM SEWER SYSTEM ISPROHIBITED. ALL CONCRETE WASTE SHALL BE PROPERLY CLEANED UP AND DISPOSED OF AT ANAPPROPRIATE LOCATION.18.CONTRACTOR SHALL PROVIDE A COMPLETED "NOTICE OF TERMINATION" TO OWNER, FOR OWNERSSUBMITTAL TO THE STATE'S GOVERNING AUTHORITY ONCE THE PROJECT IS COMPLETE, ALL DISTURBEDAREAS HAVE BEEN STABILIZED AND TEMPORARY BMPS HAVE BEEN REMOVED.19.THE CONTRACTOR SHALL CLEAN OUT ALL EXISTING AND PROPOSED INLETS, PIPES AND MANHOLES OFDEBRIS AND SEDIMENTATION AT COMPLETION OF SITEWORK. THIS WORK SHALL BE DONE TO THESATISFACTION OF THE OWNER AND LOCAL AUTHORITIES. ANY CONSTRUCTION DEBRIS OR MUD DROPPEDINTO MANHOLES, INLETS, PIPES OR TRACKED ONTO EXISTING ROADWAYS SHALL BE REMOVED IMMEDIATELYBY THE CONTRACTOR. THE CONTRACTOR SHALL REPAIR ANY EXCAVATIONS OR PAVEMENT FAILURESCAUSED BY HIS CONSTRUCTION.PAVING NOTES1.ALL PAVING WORK AND SUBGRADE PREPARATION/STABILIZATION SHALL CONFORM TO THERECOMMENDATIONS OF THE REPORT OF GEOTECHNICAL EXPLORATION, PREPARED BY OLSSON, PROJ. NO.020-2883. IN CASE OF ANY CONFLICT WITH THESE PLANS, NOTIFY OWNER IMMEDIATELY.2.UNLESS PROVIDED FOR IN THE PLANS, CONTRACTOR SHALL DEVELOP A CONCRETE PAVEMENT JOINTINGPLAN USING THE PROPOSED PAVING PLAN AND SITE CONDITIONS. JOINT LAYOUT SHALL BE IN ACCORDANCEWITH ACI 330R “GUIDE FOR THE DESIGN AND CONSTRUCTION OF CONCRETE PARKING LOTS,” AND STANDARDCONSTRUCTION PRACTICES. JOINT DETAILS SHALL BE IN ACCORDANCE WITH THE DETAILS PROVIDED IN THISPLAN SET. CONTRACTOR SHALL PROVIDE A PAVEMENT JOINTING PLAN FOR OWNER APPROVAL.3.ALL CONCRETE PAVEMENT AND CONSTRUCTION SHALL MEET KUM & GO STANDARD SPECIFICATIONS.CONCRETE PAVEMENT SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4000 PSI, TYPE I/IIPORTLAND CEMENT (UNLESS OTHERWISE SPECIFIED IN THE GEOTECHNICAL REPORT FOR HIGHER SULFATERESISTANCE), A SLUMP OF 4 INCHES +/- 1 INCH, AND AN AIR CONTENT OF 6% +/- 1%.4.PAVEMENT MUST HAVE A SOLAR REFLECTANCE INDEX (SRI) OF 29 OR HIGHER.5.ALL RADIUS/LINEAL DIMENSIONS SHOWN ON THE PAVING PLAN ARE TO FACE OF CURB UNLESS OTHERWISENOTED.6.ALL PAVEMENT MARKINGS FOR PARKING STALLS SHALL BE 4" WIDE YELLOW MARKINGS, CONFORMING TOAASHTO M248 READY MIXED YELLOW TRAFFIC PAINT.7.THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL ACCESSIBLE AREAS AND ROUTES ARE BUILT INACCORDANCE WITH THE PLANS AND THE “2010 ADA STANDARDS FOR ACCESSIBLE DESIGN”. THE SITE MAY BEINSPECTED BY CITY PERSONNEL FOR COMPLIANCE WITH THE STANDARDS.8.ADA ACCESSIBLE PARKING STALLS AND AISLES SHALL BE CONSTRUCTED WITH A MAXIMUM SLOPE OF 2.00% INANY DIRECTION. ADA ACCESSIBLE ROUTES SHALL BE CONSTRUCTED WITH A MAXIMUM CROSS SLOPE OF2.00% AND A MAXIMUM LONGITUDINAL SLOPE OF 5.00% (UNLESS RAMPS AND LANDINGS ARE PROVIDED PERADA STANDARDS). CURB RAMPS SHALL HAVE A MAXIMUM LONGITUDINAL SLOPE OF 8.33% (12:1). ACCESSIBLEMANEUVERING AREAS AT DOORS SHALL BE CONSTRUCTED WITH A MAXIMUM 2.00% IN ANY DIRECTION.CONTRACTOR SHALL FIELD VERIFY ADA GRADES AND FORMWORK PRIOR TO PLACING ANY CONCRETE.OWNER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY SHOWN ON THE PLANS.UTILITY NOTES1.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES AT PROPOSED POINTS OF CONNECTION ANDCONFIRM EXACT LOCATIONS/SIZES OF ALL UTILITY SERVICE LINE HOOKUPS TO THE BUILDING (PER MEPPLANS) PRIOR TO UTILITIES CONSTRUCTION.2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ARRANGING ONSITE MEETINGS WITH THE CITY, GOVERNINGAGENCIES, AND UTILITY OWNERS PRIOR TO THE START OF ANY CONSTRUCTION OR INSTALLATION OFUTILITIES.3.THE CONTRACTOR SHALL CONSTRUCT ALL WATER AND SANITARY SEWER SERVICE LINES AND CONNECTIONSIN ACCORDANCE WITH THE APPLICABLE STANDARDS AND SPECIFICATIONS OF THE CITY OR LOCAL UTILITYPROVIDER.4.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING UTILITY SERVICE CONNECTIONS WITH THEAPPROPRIATE UTILITY COMPANY/OWNER, AND TO OBTAIN ALL PERMITS AND PAY ALL FEES AS REQUIRED FORSERVICE CONNECTIONS TO UTILITY MAINS.5.UTILITY TRENCHES AND STRUCTURE EXCAVATIONS ARE TO BE SLOPED OR BRACED AND SHEETED ASNECESSARY FOR THE SAFETY OF THE WORKMEN AND THE PROTECTION OF OTHER UTILITIES IN COMPLIANCEWITH ALL APPLICABLE LOCAL, STATE AND FEDERAL REQUIREMENTS.6.UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE TRENCHING FOR ALL UTILITY SERVICE LINES.7.CONTRACTOR TO SET AND ADJUST ALL PROPOSED UTILITY STRUCTURES, CLEANOUTS, VALVES, METER PITS,ETC. TO FINISH GRADE. EXISTING ITEMS AFFECTED BY THE WORK SHALL BE ADJUSTED AS REQUIRED TOMATCH FINISH GRADE.8.THE CONTRACTOR SHALL COORDINATE WATER MAIN WORK WITH THE FIRE DEPARTMENT TO ENSUREADEQUATE FIRE PROTECTION IS CONSTANTLY AVAILABLE TO THE SITE AND ADJACENT PROPERTIES.CONTRACTOR WILL BE RESPONSIBLE FOR ARRANGING/PROVIDING ANY REQUIRED WATER MAIN SHUT OFFSWITH THE CITY DURING CONSTRUCTION. ANY COSTS ASSOCIATED WITH WATER MAIN SHUT OFFS WILL BETHE RESPONSIBILITY OF THE CONTRACTOR AT HIS EXPENSE.STORM SEWER NOTES1.STORM SEWER PIPE MATERIALS SHALL BE HDPE DOUBLE-WALL, SMOOTH INTERIOR PIPE (ADS N-12 ORAPPROVED EQUAL) UNLESS OTHERWISE SPECIFIED IN THE PLANS. ALL JOINTS AND STRUCTURECONNECTIONS SHALL BE SOIL-TIGHT (MINIMUM).2.STORM SEWER PIPE SHALL BE BEDDED, INSTALLED, AND BACKFILLED IN ACCORDANCE WITH THE DETAILSINCLUDED IN THE PLANS, MANUFACTURER'S INSTALLATION REQUIREMENTS, AND/OR STANDARD DETAILSINCLUDED BY REFERENCE.3.ALL CAST-IN-PLACE CONCRETE DRAINAGE STRUCTURES SHALL HAVE A MINIMUM 28 DAY COMPRESSIVESTRENGTH OF 4,000 PSI, TYPE II CEMENT (UNLESS OTHERWISE SPECIFIED) WITH AIR ENTRAININGADMIXTURES AND SHALL CONFORM TO THE LOCAL CITY'S SPECIFICATIONS.4.SMALL DIAMETER STORM SEWER CONNECTIONS (12 INCH DIAMETER AND LESS) SHALL BE MADE WITHREDUCING WYE'S, 45 DEGREE BENDS, AND REDUCING COUPLERS, UNLESS OTHERWISE INDICATED. REFERTO PLAN AND DETAILS FOR SYSTEM LAYOUT.5.ALL CAST-IN-PLACE AND PRE-FABRICATED DRAINAGE STRUCTURES WITHIN PAVED AREAS MUST BEINSTALLED TO MEET (AT A MINIMUM) AASHTO H-20/HS-20 LOAD RATING. THE GENERAL CONTRACTOR SHALLCONSULT WITH THE MANUFACTURER OF ANY PRE-FABRICATED STRUCTURE TO CONFIRM INSTALLATIONMEASURES REQUIRED TO ENSURE THE AFOREMENTIONED LOAD RATING IS ACHIEVED. FOR ALLPRE-FABRICATED NYLOPLAST® DRAIN BASINS, THE GENERAL CONTRACTOR SHALL POUR A CONCRETECOLLAR UNDER THE FRAME/GRATE/HOOD ASSEMBLY IN THE MINIMUM DIMENSIONS SPECIFIED ON THEMANUFACTURER’S STANDARD DETAIL DRAWINGS TO ACHIEVE H-20/HS-20 LOAD RATING. THE GENERALCONTRACTOR SHALL CONTACT OWNER FOR ADDITIONAL DIRECTION IF H-20/HS-20 INSTALLATION GUIDELINESCANNOT BE OBTAINED FROM THE MANUFACTURER OF ANY PROPOSED PRE-FABRICATED STRUCTURE.C0.1GENERAL NOTES23608/15/2022 SHEET NUMBER:CPM: SDM: RDM:08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT 1459 Grand AvenueDes Moines, Iowa50309P: 515-226-0128F: 515-223-9873DATE:TCDGBSCALL 811 SEVENTY-TWO HOURS PRIOR TODIGGING, GRADING OR EXCAVATING FOR THEMARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013 Know what'sbelow.before you dig.CallRwww.olsson.comTEL 303.237.2072 1525 Raleigh St. Suite 400 Denver, CO 80204 DATE REVISION DESCRIPTION OF 37CONFIDENTIAL DOCUMENT:INFORMATION CONTAINED IN THIS DOCUMENT ISPROPRIETARY TO KUM & GO, L.C. AND SHALL NOTBE DISTRIBUTED.C0.2CITY GENERAL NOTES308/15/2022 PARCEL No. 9724135000 OWNER: N/A -DUNLAP PARCEL 2- PARCEL No. 9724105001 ADDRESS: 949 E PROSPECT ROAD OWNERS: DUNLAP RICHARD W CITY ZONING: N-C FLOOD ZONE X 1.46 Acres (63,549 sq.ft.) Gross 1.20 Acres (52,347 sq.ft.) Net* Prospect Road (70' Right-of-Way Width) -35MPH Speed Limit- -SUBJECT PROPERTY- LOT 5, EAST ACRES PARCEL No. 9724106004 OWNER: MATLOCK JAMES J -DUNLAP PARCEL 1- PARCEL No. 9724106017 ADDRESS: 947 E PROSPECT ROAD OWNERS: DUNLAP RICHARD W AND PAMELA S CITY ZONING: N-C FLOOD ZONE X -CITY OF FORT COLLINS PARCEL- PARCEL No. 9724106905 ADDRESS: 945 E PROSPECT ROAD OWNERS: CITY OF FORT COLLINS CITY ZONING: N-C FLOOD ZONE X & AE -DUNLAP PARCEL 3- PARCEL No. 9724106016 ADDRESS: 1607 S LEMAY AVENUE OWNERS: DUNLAP RICHARD W CITY ZONING: N-C FLOOD ZONE X & AE PARCEL No. 9724132000 OWNER: N/A PARCEL No. 9724106006 OWNER: RHT LLC PARCEL No. 9724106030 OWNER: RHT LLC PARCEL No.8719233006 OWNER: PARK CENTRAL OWNERS ASSN PARCEL No.8719233001 OWNER: BRUNNER KENTON H (1/2) PARCEL No. 8718332004 OWNER: SURGERY CENTER OF FORT COLLINS LLCPARCEL No. 9713408192 OWNER: PRD PROPERTIES LLCPARCEL No. 9713408193 OWNER: PLAUT JOSETTE M Lake StreetLemay Avenue(Right-of-Way Width Varries)-35MPH Speed Limit-REVISIONSDATEREVISION DESCRIPTIONSHEET NUMBER: CPM: SDM: RDR: 11/24/2020#951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT ST, FORT COLLINS6400 Westown Parkway West Des Moines, Iowa 50266 P: 515-226-0128 F: 515-223-9873 DATE: ROBERT FIEBIG III RYAN HALDER DAN GARNEAU CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. before you dig.CallR ALTA/NSPS LAND TITLE SURVEY1 OF 2 ALTA/NSPS LAND TITLE SURVEY KUM & GO #951 Lot 5, East Acres, Being a Portion of the Northeast Quarter of Section 24, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado VICINITY MAP LEGEND PROSPECT ROAD LEMAY AVENUESTUART STREET PIT K I N S T R E E T RI V E R S I D E S T R E E T ELIZABETH STREET EXISTING CONDITIONSC0.3 4 OF 36 08/15/2022 Prospect Road (70' Right-of-Way Width) -35MPH Speed Limit-Lake StreetD D A A D C D D C A AA A A B BB C B B C A A C B D B D D B D D C C A AB B C B B B A A B A D A D D D D D D DD D C D B AB B A A B C A C B C B B B Lemay Avenue(Right-of-Way Width Varries)-35MPH Speed Limit-REVISIONSDATEREVISION DESCRIPTIONSHEET NUMBER: KG PROJECT TEAM: 6400 Westown Parkway West Des Moines, Iowa 50266 P: 515-226-0128 F: 515-223-9873 DATE: CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. before you dig.CallR ALTA/NSPS LAND TITLE SURVEY KUM & GO #951 Lot 5, East Acres, Being a Portion of the Northeast Quarter of Section 24, Township 7 North, Range 69 West of the 6th P.M., City of Fort Collins, County of Larimer, State of Colorado LEGEND DETAIL B 11/24/2020#951 - FORT COLLINS, CO949 E PROSPECT ST, FORT COLLINSALTA/NSPS LAND TITLE SURVEY2 OF 2 DETAIL A CPM: SDM: RDR:ROBERT FIEBIG III RYAN HALDER DAN GARNEAU EXISTING CONDITIONSC0.4 5 OF 3636 08/15/2022 E. PROSPECT RD LEMAY AVELEGEND X FO GAS GAS UGE UGE W W SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 FLAG NOTES:DEMOLITION PLANC0.5 6 36 08/15/2022 VAN 11 E PROSPECT RD S LEMAY AVE2 3 T SECTION 1 4945 4950 4955 4960 4965 4970 4975 4945 4950 4955 4960 4965 4970 4975 0+00 1+00 1+20.16 SECTION 2 4945 4950 4955 4960 4965 4970 4975 4945 4950 4955 4960 4965 4970 4975 0+00 1+00 1+31.34DOCUMENT REVISION DATE: JULY 2013FLAG NOTES: SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C1.0 7 PROJECT PLANLEGEND 36 08/15/2022 VAN S LEMAY AVETT EV EV SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 FLOOD ZONE: BENCHMARKS: NOTE: NOTES: C2.1C2.1 GRADING PLAN8 LOD LEGEND 36 08/15/2022 TT SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 FLOOD ZONE: BENCHMARKS: NOTE: DETAIL 2 DETAIL 5 DETAIL 1 C2.2C2.2 DETAILED GRADING PLAN9 LOD LEGEND NOTES: DETAIL 3 DETAIL 4 36 08/15/2022 VAN 11 S LEMAY AVE2 3 TT EV EV STORM STRUCTURE TABLESTORM PIPE TABLE DOCUMENT REVISION DATE: JULY 2013SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C2.3 10 DRAINAGE PLANLOD LEGEND: NOTE: FLOOD ZONE: BENCHMARKS: NOTES: · · · · · · · · FLAG NOTES: 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C2.4 11 DRAINAGE DETAILSHDPE PIPE BEDDING DETAILEND OF RUN “”PLAN VIEW 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C2.5 12 DRAINAGE DETAILSPROJECT NO: DRAWN BY: DATE: STORMTECH INLET MANHOLE 020-2883 06/10/2022 MWB WEIR CONFIGURATION PROJECT NO: DRAWN BY: DATE: STORMTECH OUTLET MANHOLE 020-2883 06/10/2022 MWB WEIR CONFIGURATION 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C2.6 13 DRAINAGE DETAILSDESCRIPTION DRAWING NUMBER DATE SCALE SOLIDS SETTLE ON BOTTOM ANTI-SIPHON DEVICE OIL- DEBRIS HOOD SPECIFICATION AND INSTALLATION (TYPICAL) 09/08/15 NONE OUTLET PIPE SNOUT OIL-DEBRIS HOOD HOOD SPECIFICATION FOR CATCH BASINS AND WATER QUALITY STRUCTURES MOUNTING FLANGE 1" PVC ANTI-SIPHON PIPE ADAPTER REMOVABLE WATERTIGHT ACCESS PORT, 6"-10" OPENING OUTLET PIPE (HIDDEN) CONFIGURATION DETAIL TYPICAL INSTALLATION FOAM GASKET W/ PSA BACKING (TRIM TO LENGTH) MOUNTING FLANGE DETAIL B GASKET COMPRESSED BETWEEN HOOD AND STRUCTURE (SEE DETAIL B) INSTALLATION NOTE: POSITION HOOD SUCH THAT BOTTOM FLANGE IS A DISTANCE OF 1/2 OUTLET PIPE DIAMETER (MIN.) BELOW THE PIPE INVERT. MINUMUM DISTANCE FOR PIPES < 12" I.D. IS 6". STAINLESS BOLT ANCHOR SHIELD EXPANSION CONE (NARROW END OUT) DRILLED HOLE DETAIL A ANCHOR W/ BOLT (SEE DETAIL A) 1/2 D INSTALLATION DETAILNOTES: 1. ALL HOODS AND TRAPS FOR CATCH BASINS AND WATER QUALITY STRUCTURES SHALL BE AS MANUFACTURED BY: BEST MANAGEMENT PRODUCTS, INC. 53 MT. ARCHER RD. LYME, CT 06371 (860) 434-0277, (860) 434-3195 FAX TOLL FREE: (800) 504-8008 OR (888) 434-0277 WEB SITE: www.bmpinc.com OR PRE-APPROVED EQUAL 2. ALL HOODS SHALL BE CONSTRUCTED OF A GLASS REINFORCED RESIN COMPOSITE WITH ISO GEL COAT EXTERIOR FINISH WITH A MINIMUM 0.125" LAMINATE THICKNESS. 3. ALL HOODS SHALL BE EQUIPPED WITH A WATERTIGHT ACCESS PORT, A MOUNTING FLANGE, AND AN ANTI-SIPHON VENT PIPE AND ELBOW AS DRAWN. (SEE CONFIGURATION DETAIL) 4. THE SIZE AND POSITION OF THE HOOD SHALL BE DETERMINED BY OUTLET PIPE SIZE AS PER MANUFACTURER'S RECOMMENDATION (SNOUT SIZE ALWAYS LARGER THAN PIPE SIZE). 5. THE BOTTOM OF THE HOOD SHALL EXTEND DOWNWARD A MINIMUM DISTANCE EQUAL TO 1/2 THE OUTLET PIPE DIAMETER WITH A MINIMUM DISTANCE OF 6" FOR PIPES <12" I.D. 6. THE ANTI-SIPHON VENT SHALL EXTEND ABOVE HOOD BY MINIMUM OF 3" AND A MAXIMUM OF 12" ACCORDING TO STRUCTURE CONFIGURATION. 7. THE SURFACE OF THE STRUCTURE WHERE THE HOOD IS MOUNTED SHALL BE FINISHED SMOOTH AND FREE OF LOOSE MATERIAL AND PIPE SHALL BE FINISHED FLUSH TO WALL. 8. ALL STRUCTURE JOINTS SHALL BE WATERTIGHT. 9. THE HOOD SHALL BE SECURELY ATTACHED TO STRUCTURE WALL WITH 3/8' STAINLESS STEEL BOLTS AND OIL-RESISTANT GASKET AS SUPPLIED BY MANUFACTURER. (SEE INSTALLATION DETAIL) 10. INSTALLATION INSTRUCTIONS SHALL BE FURNISHED WITH MANUFACTURER SUPPLIED INSTALLATION KIT. INSTALLATION KIT SHALL INCLUDE: A. INSTALLATION INSTRUCTIONS B. PVC ANTI-SIPHON VENT PIPE AND ADAPTER C. OIL-RESISTANT CRUSHED CELL FOAM GASKET WITH PSA BACKING D. 3/8" STAINLESS STEEL BOLTS E. ANCHOR SHIELDS OIL AND DEBRIS D FRONT VIEW SIDE VIEW SP-SN SNOUT OIL-WATER-DEBRIS SEPARATOR US Patent # 6126817, 7951294, 7857966, 8512556 Canada Patent # 2285146, 2690156, 2690156 others pending *NOTE- SUMP DEPTH OF 36" MIN. FOR UP TO 12" ID PIPE. OUTLET. FOR PIPES 15" ID AND ABOVE SUMP DEPTH OF 2.5 TO 3 TIMES PIPE ID RECOMMENDED (E.G. 5' DEEP for 24" PIPE) SEE NOTE* INLET PIPE 36 08/15/2022 100-YEAR SPRING CREEK FLOODPLAINSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF 100-YEAR SPRING CREEK FLOODPLAINLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLOD LODLOD LODLODLODLODLODLODLODLODLODLODLOD SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37PH. 1 EROSION CONTROL PLANNOTE: LEGEND: LOD SD SD SD SD OWNER/DEVELOPER/APPLICANT:ENGINEER: SF DEVELOPER/OWNER'S STATEMENT EROSION CONTROL NOTES: -- ENGINEER'S STATEMENT SWMP ADMINISTRATOR CONSTRUCTION & EROSION CONTROL SCHEDULE: C2.7 NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) BENCHMARKS: BASIS OF BEARINGS: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. FLOOD ZONE: X, AREA OF MINIMAL FLOOD HAZARD AND SPECIAL FLOOD HAZARD AREA, FLOOD ZONE AE WITH BFE (BASE FLOOD ELEVATION) OR DEPTH DETERMINED, PER FEMA FLOOD MAP 08069C0983H EFFECTIVE MAY 02, 2012 14 CONSTRUCTION SEQUENCE CHART: SITE INFORMATION TOTAL DISTURBED AREA 1.33 AC TOTAL ON-SITE DISTURBED AREA 0.92 AC TOTAL OFF-SITE DISTURBED AREA 0.41 AC TOTAL STAGING/STORAGE AREA STABILIZED STAGING AREA: 2,910.93 SF STOCKPILE MANAGEMENT AREA: 1,020.13 SF ESTIMATED % EXPOSED 16% ESTIMATED % VEGETATIVE 58% SOIL INFORMATION HYDROLOGIC SOIL GROUP C: NUNN CLAY AND SATANA LOAM WITH SHORT PASTURED/LAWN AND GRASSES WITH SHRUBS AND TREES GOUNDWATER DEPTH HIGHEST RECORDED DEPTH FROM EXISTING GRADE: 7.1' LOWEST RECORDED DEPTH FROM EXISTING GRADE: 14.0' NUMBER OF PHASES 3 PHASES TOTAL VOLUME OF IMPORT/EXPORT 1,562.62 CUBIC YARDS OF FILL STEEPEST SLOPE 4:1 RECEIVING WATERS SPRING CREEK 100 YEAR RUNOFF COEFFICIENT (AFTER CONSTRUCTION)C2 = 0.63 C100 = 0.79 SURFACE COVERAGE (AFTER CONSTRUCTION) PAVEMENT AREA = 26,095 SF ROOF AREA = 3,946 SF LANDSCAPE AREA = 9,971 SF (REFER TO LANDSCAPE PLAN BREAKDOWN OF SOD/SEED)36 08/15/2022 T EV EV SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSF SFSFSFSF SFSFSFSF SF SF SF S F SFSF100-YEAR SPRING CREEK FLOODPLAINSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SF SF SF 100-YEAR SPRING CREEK FLOODPLAINLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLOD LODLOD LODLODLODLODLODLODLODLODLODLODLOD SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37PH. 2 EROSION CONTROL PLANNOTE: LEGEND: LOD SD SD SD SD OWNER/DEVELOPER/APPLICANT:ENGINEER: SF DEVELOPER/OWNER'S STATEMENT EROSION CONTROL NOTES: -- ENGINEER'S STATEMENT SWMP ADMINISTRATOR CONSTRUCTION & EROSION CONTROL SCHEDULE: C2.8 NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) BENCHMARKS: BASIS OF BEARINGS: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. FLOOD ZONE: X, AREA OF MINIMAL FLOOD HAZARD AND SPECIAL FLOOD HAZARD AREA, FLOOD ZONE AE WITH BFE (BASE FLOOD ELEVATION) OR DEPTH DETERMINED, PER FEMA FLOOD MAP 08069C0983H EFFECTIVE MAY 02, 2012 15 CONSTRUCTION SEQUENCE CHART: SITE INFORMATION TOTAL DISTURBED AREA 1.33 AC TOTAL ON-SITE DISTURBED AREA 0.92 AC TOTAL OFF-SITE DISTURBED AREA 0.41 AC TOTAL STAGING/STORAGE AREA STABILIZED STAGING AREA: 2,910.93 SF STOCKPILE MANAGEMENT AREA: 1,020.13 SF ESTIMATED % EXPOSED 8% ESTIMATED % VEGETATIVE 92% SOIL INFORMATION HYDROLOGIC SOIL GROUP C: NUNN CLAY AND SATANA LOAM WITH SHORT PASTURED/LAWN AND GRASSES WITH SHRUBS AND TREES GOUNDWATER DEPTH HIGHEST RECORDED DEPTH FROM EXISTING GRADE: 7.1' LOWEST RECORDED DEPTH FROM EXISTING GRADE: 14.0' NUMBER OF PHASES 3 PHASES TOTAL VOLUME OF IMPORT/EXPORT 1,562.62 CUBIC YARDS OF FILL STEEPEST SLOPE 4:1 RECEIVING WATERS SPRING CREEK 100 YEAR RUNOFF COEFFICIENT (AFTER CONSTRUCTION)C2 = 0.63 C100 = 0.79 SURFACE COVERAGE (AFTER CONSTRUCTION) PAVEMENT AREA = 26,095 SF ROOF AREA = 3,946 SF LANDSCAPE AREA = 9,971 SF (REFER TO LANDSCAPE PLAN BREAKDOWN OF SOD/SEED)36 08/15/2022 VAN 11 E PROSPECT RD S LEMAY AVE2 3 TT EV EV SF SF SFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSFSF SF SFSFSF SFSFSFSF SFSFSFSF SF SF SF S F SFSF100-YEAR SPRING CREEK FLOODPLAIN UNDERGROUND WATER QUALITY TREATMENT SYSTEM (STORM TECH) 100-YEAR SPRING CREEK FLOODPLAINLODLODLODLODLODLOD LOD LOD LOD LOD LOD LOD LOD LOD LODLODLOD LODLOD LODLODLODLODLODLODLODLODLODLODLOD SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37PH. 3 & 4 EROSION CONTROL PLAN16 NOTE: LEGEND: LOD SD SD SD SD OWNER/DEVELOPER/APPLICANT:ENGINEER: DEVELOPER/OWNER'S STATEMENT EROSION CONTROL NOTES: ENGINEER'S STATEMENT SWMP ADMINISTRATOR CONSTRUCTION & EROSION CONTROL SCHEDULE: C2.9 NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) BENCHMARKS: BASIS OF BEARINGS: ASSUMING A PORTION OF THE SOUTHERLY RIGHT-OF-WAY LINE OF PROSPECT ROAD, AS MONUMENTED BY A #4 REBAR WITH 1" RED PLASTIC CAP SP ILLEGIBLE AT THE WEST END AND A CONCRETE NAIL WITH A 1" BRASS TAG LS 38479 AT THE EAST END, AS BEARING NORTH 89°49'56" EAST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, CENTRAL ZONE, NORTH AMERICAN DATUM 1983, A DISTANCE OF 848.92 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. FLOOD ZONE: X, AREA OF MINIMAL FLOOD HAZARD AND SPECIAL FLOOD HAZARD AREA, FLOOD ZONE AE WITH BFE (BASE FLOOD ELEVATION) OR DEPTH DETERMINED, PER FEMA FLOOD MAP 08069C0983H EFFECTIVE MAY 02, 2012 -- CONSTRUCTION SEQUENCE CHART: SITE INFORMATION TOTAL DISTURBED AREA 1.33 AC TOTAL ON-SITE DISTURBED AREA 0.92 AC TOTAL OFF-SITE DISTURBED AREA 0.41 AC TOTAL STAGING/STORAGE AREA STABILIZED STAGING AREA: 2,910.93 SF STOCKPILE MANAGEMENT AREA: 1,020.13 SF ESTIMATED % EXPOSED 0% ESTIMATED % VEGETATIVE 27% SOIL INFORMATION HYDROLOGIC SOIL GROUP C: NUNN CLAY AND SATANA LOAM WITH SHORT PASTURED/LAWN AND GRASSES WITH SHRUBS AND TREES GOUNDWATER DEPTH HIGHEST RECORDED DEPTH FROM EXISTING GRADE: 7.1' LOWEST RECORDED DEPTH FROM EXISTING GRADE: 14.0' NUMBER OF PHASES 3 PHASES TOTAL VOLUME OF IMPORT/EXPORT 1,562.62 CUBIC YARDS OF FILL STEEPEST SLOPE 4:1 RECEIVING WATERS SPRING CREEK 100 YEAR RUNOFF COEFFICIENT (AFTER CONSTRUCTION)C2 = 0.63 C100 = 0.79 SURFACE COVERAGE (AFTER CONSTRUCTION) PAVEMENT AREA = 26,095 SF ROOF AREA = 3,946 SF LANDSCAPE AREA = 9,971 SF (REFER TO LANDSCAPE PLAN BREAKDOWN OF SOD/SEED)36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 “ ” “” STD. EROSION CONTROL NOTESC2.10 17 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37EROSION CONTROL DETAILSC2.11 18 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37EROSION CONTROL DETAILSC2.12 19 36 08/15/2022 VAN E PROSPECT RD S LEMAY AVETT EV EV PRIVATE UTILITY NOTES: NOTE: LEGEND C3.1C3.1 UTILITY SERVICE PLAN20 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 NGS DESIGNATION "T-402" - PUBLISHED ELEV:4982.93' (NAVD88) CP-99, SET 12" SPIKE - ELEV: 4948.1' (NAVD88) BENCHMARKS: 36 08/15/2022 VAN 11 C3.2C3.2 UTILITY DETAILS21 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 UTILITY SERVICE CONNECTION 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C3.3 UTILITY DETAILS22 36 08/15/2022 VAN S LEMAY AVET SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 NOTE: C4.1C4.1 HORIZONTAL CONTROL PLAN23 LOD LEGEND NOTES: STANDARD DUTY CONCRETE PAVEMENT SECTION 36 08/15/2022 T SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 DETAIL 2 DETAIL 4 DETAIL 1 C4.2C4.2 DETAILED HORIZONTAL CONTROL PLAN24 DETAIL 3 DETAIL 5 LOD LEGEND NOTES: NOTE: 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C4.3C4.3 HORIZONTAL CONTROL POINT TABLES25 NOTE: 36 08/15/2022 VAN 11 E PROSPECT RD S LEMAY AVE3 T 4945 4950 4955 4960 4945 4950 4955 4960 -0+50 0+00 1+00 2+00 3+00 4+00 4+85.81 -0.52% -0.74% -2.01% -0.63% -0.58%-0.50% -1.22% -0.73% C4.4 26 FLOWLINE PLAN & PROFILESHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 3736 08/15/2022 E PROSPECT RD T E PROSPECT RD C4.5 27 SIGNAGE AND STRIPING PLANSHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37MATCHLINESEE BELOWMATCHLINESEE ABOVEYIELD MUST RIGHT LANE TURN RIGHT 36 08/15/2022 VAN 11 S LEMAY AVE2 3 TDOCUMENT REVISION DATE: JULY 2013C4.6 28 ADA PLANSHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 3736 08/15/2022 DOCUMENT REVISION DATE: JULY 2013PAVING DETAILSC4.7 29 PAVING DETAILSSHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 3736 08/15/2022 DOCUMENT REVISION DATE: JULY 2013PAVING DETAILSNOTES: 1. ALL ACCESSIBLE STALL PAVEMENT MARKINGS SHALL BE 4" WIDE YELLOW STRIPES. 2. ACCESSIBLE AISLE SHALL BE 8' WIDE FOR VANS. 3. ACCESSIBLE PARKING AREA SURFACE SHALL NOT EXCEED 2% SLOPE IN ANY DIRECTION. 4. A SIGN MUST MARK ACCESSIBLE PARKING. THE SYMBOL ON THE PAVEMENT IS NOT ADEQUATE. 8'8'9' PROPOSED ADA VAN ACCESSIBLE STALL SYMBOL PROPOSED ADA STALL BOLLARD-MOUNTED ADA SIGN 1. 5% 2. 0% M A X . 1. 5% 2'-6" O.C. YELLOW STRIPING, 45° CROSS HATCHMA X . VAN 19 ' NOTE: THIS ILLUSTRATION IS NOT TO SCALE AND IS INTENDED TO REPRESENT A CONCEPTUAL IMAGE OF THE BUILDING. 2. 5 'MA X . ( A N Y D I R E C T I O N ) 8'8'9' 8'4.5' 8' 4. 5 ' SOLID BLUE BACKGROUND 3" WHITE PAINT 4" WHITE BORDER SLOPE GUTTER TO MATCH SLOPE OF ADJACENT PAVEMENT 6"6"R1/4" R2" R2" REF. PAVEMENT DETAILS FOR THICKNESS NOTE: START PLACEMENT OF BOLLARDS BASED OFF CENTERLINE OF MAIN ENTRY. VAN 2.5' 5' TYP CL PLAN VIEW ISOLATION JOINT SAW CUT CONSTRUCTION JOINT 40' TYP. 30' MIN.ENTRANCE THROAT DEPTHPROPOSED APPROACH 3' (UNLESS OTHERWISE NOTED ON PLANS) HEAVY BROOM FINISHED CONCRETE (SEE DETAIL L - SHEET C4.6) CURB R2' R2' EXTEND 1' BEYOND CURB RETURN EDGE OF ROLLOVER TO BE FLUSH WITH EDGES OF SIDEWALK 3' TRANSITION (TYP) ROLLOVER CURB SLOPE GUTTER TO MATCH SLOPE OF ADJACENT PAVEMENT R9" R4" 3"11" REF. PAVEMENT DETAILS FOR THICKNESS 6"3' UNLESS NOTED OTHERWISE 4" INTEGRAL COLORED CONCRETE 4" MIN ASTM D448 #57 STONE OR APPROVED ALTERNATIVE PROPOSED SUBGRADE CONSTRUCTION JOINT WITH 12" #4 DOWELS @ 24" O.C. PER SPECIFICATIONS DEPTH TO MATCH THAT OF ADJACENT CONCRETE SECTION JOINT SEALING MATERIAL C4.8 30 PAVING DETAILSSHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 3736 08/15/2022 Ø4.70" I.D. NOMINAL WALL: 0.125" R1" Ø4.95" O.D 3.25" 1" 10" 3' NOTE: BOLLARD COVERS SUPPLIED BY OWNER AND INSTALLED BY CONTRACTOR BLACK PROTECTIVE BOLLARD COVER MADE OF HDPE INSTALLATION: 1) UTILIZE GREAT STUFF PROTM WALL AND FLOOR ADHESIVE TO ADHERE BOLLARD COVER TO STEEL BOLLARD. FOLLOW PRODUCT INSTRUCTIONS 2) SPRAY PRODUCT INSIDE BOLLARD COVER (DO NOT DRILL HOLES) 3) INSTALL BOLLARD COVER OVER STEEL BOLLARD 4) FACE PRODUCT INFORMATION LABEL TOWARDS BUILDING “” “” INNOPLAST BOLLARD (TYP.) CANOPY COLUMN WRAP CANOPY COLUMN WRAP "ZIP STRIP" FOAM EXPANSION MATERIAL OR APPROVED EQUAL "ZIP STRIP" FOAM EXPANSION MATERIAL OR APPROVED EQUAL FUEL DISPENSER NOTE: SAW CUT, SOFT CUT OR HAND TOOL ALL EXPANSION JOINTS AS SHOWN. NOTE: SEALANT SHALL BE USED AT ALL JOINTS CONCRET JOINT RUNS ALONG OUTSIDE EDGE OF BOLLARDS24'STARTING GATE CANOPY CONFIGURATION 4.16' 10" X 10" CANOPY COLUMN 10" X 10" CANOPY COLUMN COLORED CONCRETE (SEE DETAIL, THIS SHEET) FLAG POLE C4.9 31 PAVING DETAILSSHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 PROPANE CAGE BOLLARD PROTECTION 36 08/15/2022 STOP SIDE VIEWFRONT VIEW A fresh take on convenience! Go Fresh OPENING (MONTH) (DATE)! NOW HIRING. Visit kumandgo.com ELEVATION We’re Hiring Apply at careers.kumandgo.com A fresh take on convenience! Go Fresh OPENING SOON! NOW HIRING. Visit kumandgo.com PRODUCT NO. *Available in powder coat and DuraCoat finishes BP4-02-SM-PF 3 1 2 4 36" 4.88"4.5"3 X Ø 0 . 5 6 " C4.10 32 SIGNAGE & SITE DETAILSSHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 20 ft 36 08/15/2022 E PROSPECT RD S LEMAY AVEE PROSPECT RDS LEMAY AVEDOCUMENT REVISION DATE: JULY 2013FLAG NOTES: SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 C5.0 33 TRAFFIC SIGNAL PLANLEGEND 36 08/15/2022 T EV EV VAN 11 S LEMAY AVE2 3 T RFCFS MV BF F D 3 4"3 4" 8 8 8 8 8 8 8 8 15 15 15 15 15 1515 15 15 15 15 15 15 15 51 81 81 81 15 15 15 51 81 12 12 12 1212 12 12 12 12 12 12 12 12 12 12 12 1212 12 12 12 12 12 12 12 12 12 12 3 4" 3 4"3 4" 1" 3 4"11 4"3 4" 3 4" 3 4"3 4"1" 3 4" 3 4" 3 4" 3 4" 3 4"11 4" 114" 17.66 1" 26.76 1" 52.40 1" 61.80 1" 720.8 1" 810.4 1" 91.90 1" 1.9010 1" 88 8 8 8 8 8 8 8 315.7 1" 3 4" 46.98 1" F F F F di di di di dc dc dc dc dc dc dc dc dc dc M 3 4" 114"11 4" 11 4" 2" 11 4" 11 4" 11 4" 114" 11 4" 11 4" 2" FHTQ 8 8 8 8 Q TQ FHT 12 12 12 12 12 Q TQ FHT 15 15 15 15 15 10468 12 15 18 4 6 8 01 21 51 81 F di 0.6 1.0 2.0 MV D BF C dc RF FS M #" ## IRRIGATION SCHEDULE CRITICAL ANALYSIS VALVE SCHEDULEDOCUMENT REVISION DATE: JULY 2013SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 I1.1 FINAL IRRIGATION PLAN34 NOTE: FLAG NOTES: 36 08/15/2022 7 DAY WATERING SCHEDULE 3 DAY WATERING SCHEDULERUNTIME SCHEDULE SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 I1.2 IRRIGATION DETAILS 135 GENERAL IRRIGATION NOTES EXTEND 18" BEYOND EDGE OF PAVEMENT 6" MIN. BELOW PAVEMENT 5 PIPE SLEEVE NOT TO SCALE 1 QUICK COUPLER VALVE MODEL 5RC SERIESNOT TO SCALE 4 POP-UP SPRAY SPRINKLER 1806 WITH SWING PIPENOT TO SCALE 3 ELECTRIC REMOTE-CONTROL VALVE PEBS SERIESNOT TO SCALE 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2 XCZ-100-PRB-LC 1" LIGHT COMMERCIAL CONTROL ZONE KIT NOT TO SCALE 36 08/15/2022 SHEET NUMBER: CPM: SDM: RDM: 08/05/2022#0951 - FORT COLLINS, COKG PROJECT TEAM:949 E PROSPECT1459 Grand Avenue Des Moines, Iowa 50309 P: 515-226-0128 F: 515-223-9873 DATE: TC DG BS CALL 811 SEVENTY-TWO HOURS PRIOR TO DIGGING, GRADING OR EXCAVATING FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES.DOCUMENT REVISION DATE: JULY 2013Know what's below. before you dig.CallR www.olsson.comTEL 303.237.20721525 Raleigh St. Suite 400Denver, CO 80204DATEREVISION DESCRIPTION OF 37 I1.3 IRRIGATION DETAILS 236 ROOF RAIN BIRD WR2-RFS RAIN SENSOR 2 NOT TO SCALE MASTER CONTROL VALVE ASSEMBLY5 MANUAL DRAIN VALVE6 MULTI-PORT DRIP EMITTER8 THRUST BLOCK THRUST BLOCK MINIMUM BEARING SURFACE AREA FITTING SIZE 22.5° BEND 45° BEND 90° BEND TEE/ PLUG 3"0.43 0.84 1.52 1.08 4"0.70 1.37 2.49 1.77 6"1.51 2.95 5.39 3.83 8"2.56 5.02 9.16 6.50 10"3.97 7.79 14.21 10.10 12"5.60 10.96 20.00 14.21 3 GATE / BALL SHUT-OFF VALVE4 EMITTER SIZING SCHEDULE PLANT SIZE FLOW / PLANT EMITTER # OF EMITTERS 9 PIPE LAYOUT - SERVICE LINE CONNECTION7 TRENCHING DEPTH10 ELEVATION SECTION ET Pro3 2-Wire WeatherTRAK WEATHERTRAK ET PRO3 2-WIRE WALL MOUNT1 36 08/15/2022