Loading...
HomeMy WebLinkAboutJEROME STREET STATION - PDP210009 - DOCUMENT MARKUPS - ROUND 4 - UTILITY PLANS (5)VAULT ELEC VAULT CABLE VAULT ELEC VAULT ELEC VAULT CABLE TRAFFIC VAULT VAULT ELEC HY DVAULT CABLE VAULT ELEC VAULT ELEC VAULT CABLE VAULT ELEC VAULT CABLE C.O.H2OCONTROL IRR CONTROL IRR C.O. C.O.C.O.CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR S S D D S S / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XX XXXXXXXXWWWWWWWW WWWWWWEEWW WWWWW WWWWWWWWWW W W W W W W W WEEEEEEEEEE EGGGGGGGGGGGGGGG G G ST ST ST ST ST ST ST ST ST SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSS GGGGGGGGGGGGGGG G G SSSSSSSSSSSSSSS G G G G G G G GGGGTE EEEEEEEEEEEEEEEEEEEEW WWWWWWWSSSSS E E T EE E E E E E EE E T EE EWWWWW WWWWWWWWWWWWWWWWW W WW SSSSSSSSSSSSSSSSSWWSSSSSSSSSSSSSWWW FFFF FW S TEE E E E EFFSWEXISTING 15' UTILITY EASEMENT 50' - EXISTING 9' UTILITY EASEMENT ALL KINDS INVESTMENTS, 910 N COLLEGE AVE BOWL FORT COLLINS LLC 830 N COLLEGE AVE CONNECT TO EXISTING 12" WATER MAIN 12"x8" WET TAB w/TB 1 - 8" GV (W) N:135549.09 E:195507.31 CONNECT TO EXISTING 12" WATER MAIN STUB AND GTV 1 - 12" GV AND 8" REDUCER (W) N:135260.33 E:195501.40 90° BEND w/ TB 1 - FH ASSEMBLY (N) N:135268.47 E:195382.93 FH TEE N:135550.51 E:195380.53 8" PVC8" PVC BUILDING 8 (7-PLEX) BUILDING 7 (6-PLEX) BUILDING 5 (5-PLEX) BUILDING 4 (5-PLEX) BUILDING 2 (4-PLEX) BUILDING 3 (4-PLEX) BUILDING 1 (6-PLEX) SSMH B1-1 SSMH B1 SSMH B2 GANGED WATER SERVICE CONNECTION STOP VALVE AT MAIN CONNECTION & EACH CONNECTION EXTERIOR TO HOUSE (TYP.) EX-STORM MH RIM=4970.54 INV=4958.66 (W, E) EXISTING 36" RCP STORM LINE EX-SSMH RIM=4968.77 INV IN=4960.95 (E) INV OUT=4960.87 (S) EX-SSMH B RIM=4967.69 INV IN=4959.99 (N) INV OUT=4959.82 (S) EX-SAN MH RIM=4966.71 INV=4960.03 (W, S) EXISTING 24" SANITARY PVC EXISTING 8" WATER LINE PROPOSED ELECTRICAL TRANSFORMER (TYP.) PROPOSED CURB CUT WATERLINE B WATERLINE C SANITARY SEWER MANHOLE (TYP.) PROPOSED FIRE SERVICE (TYP.) PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SEWER SERVICE (TYP.) 8" PVC 8" PVC8" PVC8" PVC100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) PROPOSED 25' UTILITY EASEMENT EXISTING 20' SEWER LINE EASEMENT TRACT A AD&UE 8" STUB N:135283.36 E:195362.07 76' ROW 22.5° BEND w/ TB N:135268.47 E:195465.37 PROPOSED ELECTRIC SERVICE EXTENDING FROM TRANSFORMER BOX PRIVATE (TYP.) SheetJEROME STREET STATIONThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 14 U1 UTILITY PLAN6 NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 E. VINE DRIVEN. COLLEGE AVENUEKEYMAP JEROME STREETCAJETA N S T . NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 12.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NHBZ. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV FPROPOSED FIRE SERVICE UDPROPOSED UNDERDRAIN U1 U2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R VAULT CABLE VAULT ELEC VAULT CABLE VAULT ELEC VAULT CABLE VAULT ELEC VAULT ELECHYDS S D D D/ / / / / / / // / / / / / / // / / / / / / // / / / / / / /WWWWWWWWWWWWWW EGGGGGGGGGGGGGGGGGSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSTSS S GAS WXGGS S SSSSSSGGS S SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSOHUOHUOHUOHUOHUOHUFESWWWGGGGGGGGGGGGGGGGGG G E EEMH/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /FE SF E SFE SST STST STST ST GASOHUSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSD ST ST ST ST ST ST ST STSTSTG G G G G G G G G G G G G G EEEEEEEEEEEEEEEEEEEEEWWWWEE E T EE E TEEEEEE E E E E E E E E E E E E E E E E E UD UD UD UD GGGGGWWWWWWWWWWWWSSSSSSSSSSSSSWWSSSSSSFF FFFW WWW W W WWWWWWWWWWWWWWWWSSSSS SSSS S SSS SSSSS S S SSSST WUD UD26' - EXISTING 9' UTILITY EASEMENT EXISTING 30' GAS LINE EASEMENT LAKE CANAL COMPANY EASEMENT PER PLAT OF OLD TOWN NORTH LAKE CANAL EASEMENT PER PLAT OF OLD TOWN NORTH BOWL FORT COLLINS LLC 830 N COLLEGE AVE PROPOSED POND PROPOSED POND CONNECT TO EXISTING 12" WATER MAIN STUB AT GV N:134911.20 E:195614.04 11.25° BEND w/TB 1 - 12" x8" REDUCER (W) N:134908.72 E:195609.34 11.25° BEND w/TB N:134864.70 E:195476.87 11.25° BEND w/TB N:134849.50 E:195396.93 11.25° BEND w/TB N:134855.14 E:195323.91 90.00° BEND w/TB 1 - 8"x6" REDUCER (S) 1 - 6" GV (S) 1 - FH ASSEMBLY (S) N:134896.99 E:195122.23 8" PVC 8" PVC 8" PVC 8" PVC 12" PVC BUILDING 10 (7-PLEX) BUILDING 11 (7-PLEX) BUILDING 12 (4-PLEX) BUILDING 9 (5-PLEX) BUILDING 8 (7-PLEX) BUILDING 8 (7-PLEX) BUILDING 7 (6-PLEX) SSMH A(E)2 SSMH A(E)1 SSMH A(W)1 SSMH A SSMH A(E)3 SSMH B2 SSMH B3 PROPOSED 8" SANITARY SEWER LINE SANITARY SEWER MANHOLE (TYP.) STORM MANHOLE (TYP.) PROPOSED STORM LINE EXISTING SANITARY SEWER CONNECT TO EXISTING STORM LINE EXISTING STORM LINE PROPOSED 8" WATERLINE A EXISTING 18" RCP 24" RCP EX-SAN MH RIM=4963.95 INV IN=4956.53 (N) INV IN=4956.25 (W) INV OUT=4955.75 (S) SAN MH RIM=4964.63 INV IN=4957.59 (NW, E) INV OUT=4957.42 (S) EXISTING FIRE HYDRANT EXISTING STREET LIGHT (TYP.) EXISTING 12" WATER LINE EXISTING UNDERGROUND ELECTRIC UTILITY PROPOSED TRANSFORMER (TYP.) PROPOSED STORM LINE PROPOSED STORM LINE PROPOSED CURB CUT PROPOSED SIDEWALK CHASE (TYP.) NON-POTABLE WATER SERVICE AND METER PROPOSED SANITARY SEWER MANHOLE IN EXISTING MAIN PROPOSED RAIN GARDEN & UNDERDRAIN PROPOSED RAIN GARDEN & UNDERDRAIN GANGED WATER SERVICE CONNECTION STOP VALVE AT MAIN CONNECTION & EACH CONNECTION EXTERIOR TO HOUSE (TYP.) SANITARY & STORM SEWER CROSSING STORM B.O.P. ELEV. = 4963.20' SAN. T.O.P. ELEV. = 4960.49' TOTAL VERTICAL SEPARATION = 2.17' PROPOSED CURB CUT SANITARY SEWER MANHOLE (TYP.) PROPOSED FIRE SERVICE (TYP.) PROPOSED WATER SERVICE (TYP.) PROPOSED SANITARY SEWER SERVICE (TYP.) PROPOSED FES (TYP.) 8" PVC 8" PVC 8" PVC 8" PVC 8" PVC8" PVCCONCRETE WEIR SLOPE PROTECTION (SCOUR-STOP) CONCRETE WEIR SLOPE PROTECTION (SCOUR-STOP) SLOPE PROTECTION (SCOUR-STOP) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) PROPOSED RAIN GARDEN & UNDERDRAIN EXISTING 30' UTILITY & DRAINAGE EASEMENT PROPOSED 30' SEWER LINE EASEMENT EXISTING 10' DRAINAGE EASEMENT PROPOSED 25' UTILITY EASEMENT 5' UTILITY EASEMENT EXISTING 20' SEWER LINE EASEMENT EXISTING 20' SEWER LINE EASEMENT EXISTING 15' DRAINAGE EASEMENT EXISTING 30' UTILITY EASEMENT TRACT B AD&UE TRACT A AD&UE TRACT B AD&UE SheetJEROME STREET STATIONThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 14 U2 UTILITY PLAN7 NORTH ( IN FEET ) 1 inch = ft. Feet03030 30 60 90 E. VINE DRIVEN. COLLEGE AVENUEKEYMAP JEROME STREETCAJETA N S T . NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES WATER AND WASTEWATER DESIGN CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A MINIMUM OF 4.5' AND MAXIMUM OF 5' WATER LINE COVER FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH LARIMER COUNTY URBAN AREA STREET STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. 12.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NHBZ. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV FPROPOSED FIRE SERVICE UDPROPOSED UNDERDRAIN U1 U2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R VAULT ELEC VAULT CABLE VAULT ELEC VAULT ELEC VAULT CABLE TRAFFICVAULT VAULT ELEC VAULT CABLE VAULT ELEC VAULT ELEC VAULT CABLE VAULT ELEC VAULT CABLE VAULT ELEC VAULT CABLE VAULT ELEC VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR S S D D S S S D D D / / / / / / / // / / / / / / // / / / / / / // / / / / / / /X/ / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /XXXXXXST ST ST ST STVAULT ELEC D S CONTROL IRR CONTROL IRR GASFOFO FOFOFOS S SOHUOHUOHUFESLID MH / / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / // / / / / / / /FE SFE SFE SST STST GAS S D ST ST ST ST STSTUD UD UD ALL KINDS INVESTMENTS, 910 N COLLEGE AVE NORTH COLLEGE AVENUE(PUBLIC R.O.W. VARIES)BOWL FORT COLLINS LLC 830 N COLLEGE AVE LAND W PROPERTIES 742 N COLLEGE AVE PROPOSED POND PROPOSED POND EXISTING 18" STORM LINE (RCP) PROPOSED TOP OF POND PROPOSED TOP OF POND PROPOSED SIDEWALK CHASE (TYP.) PROPOSED CURB CUT PROPOSED RAIN GARDEN AND UNDERDRAIN PROPOSED RAIN GARDEN AND UNDERDRAIN PROPOSED RAIN GARDEN AND UNDERDRAIN PROPOSED CHASE 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE)100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 500 YR FLOODPLAIN (CURRENT EFFECTIVE) 100 YR FLOODPLAIN (CURRENT EFFECTIVE) TRACT A AD&UE TRACT B AD&UE TRACT A AD&UE TRACT B AD&UE SheetJEROME STREET STATIONThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 14 OG1 OVERALL GRADING PLAN8 NORTH ( IN FEET ) 1 inch = ft. Feet05050 50 100 150 E. VINE DRIVEN. COLLEGE AVENUEKEYMAP JEROME STREETCAJETA N S T . PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL BEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. 6.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA REGULATED, 100 YEAR AND 500 YEAR POUDRE RIVER FLOODPLAIN. ANY DEVELOPMENT WITHIN THE FLOODPLAIN MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE. 7.ANY CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE (E.G. STRUCTURES, SIDEWALK OR CURB & GUTTER INSTALLATION/REPLACEMENT, UTILITY WORK, LANDSCAPING, ETC.) MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT, THE APPROPRIATE PERMIT APPLICATION FEES, AND APPROVED PLANS. 8.CONSTRUCTION OF RESIDENTIAL AND/OR MIXED USE STRUCTURES IS PROHIBITED IN THE POUDRE RIVER 100YEAR FLOODPLAIN. 9.OUTSIDE STORAGE OF EQUIPMENT OR FLOATABLE MATERIALS WHETHER PERMANENT OR TEMPORARY IS PROHIBITED IN THE 100YEAR FLOODPLAIN. 10.AT RISK POPULATIONS, ESSENTIAL SERVICES, HAZARDOUS MATERIALS, AND GOVERNMENT SERVICES CRITICAL FACILITIES ARE PROHIBITED IN THE 100YEAR FLOODPLAIN. 11.THE APPLICANT ACKNOWLEDGES THAT THIS SITE DEVELOPMENT PLAN DOES NOT COMPLY WITH THE CURRENT REGULATORY FLOODPLAIN. PERMITS CANNOT BE ISSUED FOR RESIDENTIAL STRUCTURES IN THE REGULATORY FLOODPLAIN UNTIL A LOMR IS APPROVED THROUGH FEMA. IT IS AT OUR OWN RISK THAT WE CONTINUE THROUGH THE PLANNING PROCESS. 12.THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NHBZ. 13.ADA VISITABLE UNITS INCLUDE ALL UNITS IN BUILDINGS 3, 5, 7, 8, 10, 11, AND 12. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK PROPOSED OVERLAND FLOW CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R