Loading...
HomeMy WebLinkAboutFORT COLLINS NISSAN-KIA - FDP220011 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANSCOLLEGE AVE (HWY 287)VENUS AVENUEMILKY WAY MARS DRIVEEXISTING BUILDING TO REMAIN #5822EXISTING#5828EXISTING#5834EXISTING#200 EXISTING #206 EXISTING #214 EXISTING #218 EXISTING #201 EXISTING#5836EXISTING#5835EXISTING#5817 EXISTING #224 EXISTING#230 EXISTING PROPOSED 8" WATER SEE SHEET C3.21 NISSAN DEALERSHIP BUILDING KIA DEALERSHIP BUILDING PROPOSED 4" SANITARY SERVICE PROPOSED 6" FIRE SERVICE PROPOSED 4" SANITARY SERVICE PROPOSED 2" WATER SERVICE EXISTING 24" IRRIGATION CONNECT TO EXISTING 24" IRRIGATION LATERAL CONNECT TO EXISTING 6" WATER PROPOSED 8" WATER SEE SHEET C3.22 STORM LINE H3 SEE SHEET C3.36 PROPOSED 8" SANITARY SEE SHEET C3.10 CONNECT TO EXISTING SANITARY MANHOLE EXISTING HYDRANT CONNECT TO EXISTING 6" WATER EXISTING FIBER OPTIC TO REMAIN STORM LINE D SEE SHEET C3.33 STORM LINE B SEE SHEET C3.33 STORM LINE C SEE SHEET C3.33 STORM LINE F SEE SHEET C3.34 PROPOSED 24" IRRIGATION LINE SEE SHEET C3.40 STORM LINE H SEE SHEET C3.35 EXISTING GAS MAIN TO RELOCATED (SEE NOTE 12 AND DRY UTILITY NOTES) PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT EXISTING NATURAL HABITAT BUFFER ZONE EXISTING SANITARY EXISTING 8" SANITARY BIORETENTION POND A2 DETENTION POND A1 CONNECT TO EXISTING 24" IRRIGATION LATERAL LOT 2 BLOCK 1 TRACT A (INCLUDES BLANKET DRAINAGE EASEMENT TRACT B LOT 1 BLOCK 2 LOT 1 BLOCK 1 RELOCATED GAS LINE EXISTING XCEL GAS TO BE MOVED WITH GRADING (SEE NOTE 12 AND DRY UTILITY NOTES) EXISTING ELECTRIC TO BE LOWERED AND RELOCATED WITH HWY 287 WIDENING (SEE NOTE 12 AND DRY UTILITY NOTES) RELOCATED GAS AND UNDERGROUND ELECTRIC (SEE NOTE 12 AND DRY UTILITY NOTES) PROPOSED TRANSFORMER PROPOSED 6" FIRE SERVICE FIRE DEPARTMENT CONNECTION FIRE DEPARTMENT CONNECTION BIORETENTION POND A3 DETENTION POND A1 9' UTILITY EASEMENT 9' UTILITY EASEMENT 30' UTILITY EASEMENT 30' UTILITY EASEMENT 30' UTILITY EASEMENT 20' UTILITY EASEMENT 15' UTILITY EASEMENT 20' IRRIGATION EASEMENT UTILITY EASEMENT (WIDTH VARIES) PROPOSED FIRE HYDRANT EXISTING SANITARY STUB TO BE ABANDONED PROPOSED SAND-OIL INTERCEPTOR PROPOSED SAND-OIL INTERCEPTOR PROPOSED 2" WATER SERVICE PRIMARY ELECTRIC PER CITY OF FORT COLLINS 20' DRAINAGE EASEMENT 60' UTILITY & DRAINAGE EASEMENT 15' UTILITY EASEMENT 20' IRRIGATION EASEMENT 20' UTILITY EASEMENT PROPOSED ROOF DRAIN SEE SHEET C3.36 VENUS AVENUERELOCATED FIBER-OPTIC RELOCATED FIBER-OPTIC VAULT 10' UTILITY EASEMENT PROPOSED TRANSFORMER STORM LINE H4.2 SEE SHEET C3.37 PUBLIC ROW OVERHEAD LIGHT PER CITY OF FORT COLLINS (TYP.) PUBLIC ROW OVERHEAD LIGHT PER CITY OF FORT COLLINS (TYP.) ONSITE OVERHEAD LIGHT (SEE ELEC. PLANS, TYP.) STORM LINE E SEE SHEET C3.33 PROPOSED 8" SANITARY SEE SHEET C3.10 STORM LINE G SEE SHEET C3.34 STORM LINE H SEE SHEET C3.35 STORM LINE H SEE SHEET C3.35 STORM LINE H4.3 SEE SHEET C3.37 PROPOSED 24" IRRIGATION LINE SEE SHEET C3.40 PROPOSED 24" IRRIGATION LINE SEE SHEET C3.40 STORM LINE H4.2 SEE SHEET C3.37 STORM LINE H4.2-1 SEE SHEET C3.37 PROPOSED 8" WATER SEE SHEET C3.21 PROPOSED ROOF DRAIN SEE SHEET C3.36 PROPOSED ROOF DRAIN SEE SHEET C3.36 PROPOSED ROOF DRAIN SEE SHEET C3.36 PROPOSED ROOF DRAIN SEE SHEET C3.35 PROPOSED ROOF DRAIN SEE SHEET C3.32 SANITARY SERVICE CONNECTION SEE SHEET C3.10 SANITARY SERVICE CONNECTION SEE SHEET C3.10 PREPARED FOR:JOB NUMBER SHEET NUMBER SHEETSOF DATE SUBMITTED:VERTICAL: HORIZONTAL: SCALEPRELIMINARYPLANSNOT FOR CONSTRUCTIONPROJ. MGR:DRAWING NAME:PATH:DESIGNER:DATE:TIME:The engineer preparing these plans will not be responsible for, or liable for, unauthorizedchanges to or uses of these plans. All changes to the plans must be in writing and mustbe approved by the preparer of these plans.NO.BYDATECAUTIONREVISIONS:CIVIL ENGINEERING & CONSULTING UNITED CIVIL Design Group 19 OLD TOWN SQUARE #238FORT COLLINS, CO 80524 (970) 530-4044 www.unitedcivil.com TCC CORPORATIONFORT COLLINS NISSAN-KIA8/3/2022U21004 1" = 40' 1" = N/A 8/3/202210:10:36 AME:\UNITED CIVIL DROPBOX\PROJECTS\U21004 - NISSAN DEALERSHIP\CADD\CP\C3.0X - DETAILED UTILITY PLANS.DWGC3.0X - DETAILED UTILITY PLANS####C3.02 88DETAILED UTILITY PLAN - SOUTH20 NORTH0 40'80' SCALE: 1" = 40' 20' LEGEND COLLEGE AVE (HWY 287)VENUS AVENUEMILKY WAY N KEYMAP 1. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL CONTACT THE ENGINEER. 2. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 3. THE PROPOSED CONSTRUCTION WILL BE IN CLOSE PROXIMITY TO SEVERAL UNDERGROUND UTILITIES. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY PROVIDERS PRIOR TO AND DURING CONSTRUCTION TO MINIMIZE SERVICE INTERRUPTIONS TO SURROUNDING BUILDINGS OR PROPERTIES. 4. THE PLUMBING CONTRACTOR SHALL TERMINATE UTILITY LATERALS 5' OUTSIDE OF BUILDING UNLESS NOTED OTHERWISE. EXACT LOCATIONS (HORIZONTAL AND VERTICAL) OF ALL UTILITY CONNECTIONS INTO THE PROPOSED BUILDING SHALL BE COORDINATED WITH APPROVED ARCHITECTURAL DRAWINGS. 5. REFER TO APPROVED SITE ELECTRICAL PLANS FOR ALL CONDUITS AND POWER LINE ROUTING FOR SITE LIGHTING. 6. WATER AND SEWER SERVICE PROVIDED BY THE FORT COLLINS-LOVELAND WATER AND SOUTH FORT COLLINS SANITATION DISTRICTS. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER EACH DISTRICT'S STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 7. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5'. MAXIMUM COVER SHALL BE 6'. 8. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER & WATER MAINS & SERVICES. 9. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 10. SANITARY SEWER SERVICES SHALL BE SDR-35 PVC. 11. WATER MAINS AND FIRE SERVICES SHALL BE AWWA C-900 DR18 PVC. WATER SERVICES UP TO 2" SHALL BE TYPE K COPPER. 12. CONTRACTOR SHALL COORDINATE ALL UTILITY DEMOLITION AND/OR RELOCATION ITEMS WITH THE APPROPRIATE UTILITY PROVIDER PRIOR TO BEGINNING ANY ONSITE DEMOLITION. CABLE TV LINE ELECTRIC LINE OVERHEAD ELECTRIC LINE FIBER OPTIC LINE GAS LINE ABANDONED GAS LINE G GAS METER IRRIGATION LINE SANITARY MANHOLE SANITARY MAIN SANITARY SERVICE SANITARY SERVICE CLEANOUT DOWNSPOUT FLARED END SECTION STORM INLET STORM MANHOLE STORM OUTLET STRUCTURE STORM PIPE RIP RAP TELEPHONE LINE OVERHEAD TELEPHONE LINE UTILITY POLE AND GUY WIRES FIRE DEPARTMENT CONNECTION FIRE HYDRANT FIRELINE WATER FITTINGS WATER MAIN WATER SERVICE WATER METER DRY UTILITY CONDUIT DS THRUST BLOCK GATE VALVE FIBER, GAS, ELECTRIC, TELEPHONE PEDESTAL NOTES 1. THE LOCATION OF PROPOSED DRY UTILITIES AS SHOWN ON THIS DRAWING ARE SHOWN FOR HORIZONTAL ALIGNMENTS ONLY AND ARE APPROXIMATE. FINAL DESIGNS OF DRY UTILITIES WILL BE PERFORMED BY THE APPROPRIATE UTILITY COMPANY. 2. GAS SERVICE TO BE PROVIDED BY XCEL ENERGY. XCEL SHALL INSTALL GAS MAINS, SERVICES AND METERS. THE COST OF ALL SERVICE INSTALLATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. THE SERVICE LOCATIONS AS SHOWN ON THIS DRAWING ARE APPROXIMATE ONLY. FINAL LOCATION TO BE DETERMINED BY XCEL, BUT SHALL MAINTAIN SPECIFIED CLEARANCES FROM OTHER UTILITIES. 3. ELECTRIC SERVICE TO BE PROVIDED BY CITY OF FORT COLLINS. THE CITY SHALL INSTALL SERVICE AND THE TRANSFORMER. THE COST OF ALL SERVICE INSTALLATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. THE SERVICE LOCATION AS SHOWN ON THIS DRAWING IS APPROXIMATE ONLY. FINAL LOCATION TO BE DETERMINED BY THE CITY, BUT SHALL MAINTAIN SPECIFIED CLEARANCES FROM OTHER UTILITIES. 4. ALL CONDUIT PLACED BY THE CONTRACTOR FOR CABLE, PHONE AND INTERNET SHALL BE EQUIPPED WITH PULL TAPE AND LOCATE WIRE PER THE SPECIFICATIONS OF EACH UTILITY COMPANY. DRY UTILITY NOTES