H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C6.1_Storm B_P&P.dwg - Nate Whitcomb - 8/17/2022Init.# Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
08.17.2022
HFH000022
KEYMAP
Know what's
before you dig.
SCALE: 1"=50'
0 20 5010
ALS
JEP
STORM B2,B3 PLAN & PROFILE
C6.3
SCALE: 1"=50'
0 20 5010
Please add a note to this sheet stating
that at the time of City approval of these
plans, the railroad has not yet given
permission for this storm line to cross
railroad right-of-way. The note should also
state that City approval of these plans
does not constitute approval of any work
within railroad right-of-way. Please call out
this section of storm line as not to be
constructed before permission has been
given by the railroad.
City of Fort Collins
Development Review Engineering
Sophie Buckingham, EI
Date:09/01/2022
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C7.0-C7.2_Waterline 1_P&P_F1.dwg - Matthew Kasch - 8/17/2022Init.# Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
08.17.2022
HFH000022
1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALLBE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK.BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES ANDSHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES.
2.ALL WATER AND SEWER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER DISTRICT AND BOXELDER SANITATION DISTRICTSTANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION.
3.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
4.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVEUTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD.
5.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, STORM SEWER MAINS, WATERMAINS & SERVICES.
6.CONFIRM EXISTING SANITARY SEWER INVERT IN THE FIELD. IF IT DOESN'T MATCH THE ASSUMED INVERT, CONTACT THE DESIGN ENGINEER.
7.CONFIRM EXISTING STORM SEWER INVERT IN THE FIELD. IF IT DOESN'T MATCH THE ASSUMED INVERT, CONTACT THE DESIGN ENGINEER.
8.CONFIRM HORIZONTAL LOCATION OF WATER TO EXISTING LOCATIONS PRIOR TO CONSTRUCTION. CONTACT DESIGN ENGINEER WITH ANYDISCREPANCIES.
9.MINIMUM SEWER SLOPE IS 1.04% (18" / 1') FOR 6" DIAMETER AND 2.08% (14" / 1') FOR 4" DIAMETER.
10.CONTRACTOR TO COORDINATE GAS, ELECTRIC AND TELEPHONE CABLE SERVICES.
11.THE PLUMBING CONTRACTOR SHALL TERMINATE UTILITY LATERALS 5' OUTSIDE OF BUILDING UNLESS OTHERWISE NOTED. EXACT LOCATIONS(HORIZONTAL AND VERTICAL) OF ALL UTILITY CONNECTIONS INTO THE PROPOSED BUILDING SHALL BE COORDINATED WITH THE APPROVEDARCHITECTURAL DRAWINGS.
12.ROOF DRAIN CONNECTIONS TO BE COORDINATED WITH FINAL ARCHITECTURAL PLANS.
KEYMAP
LINEMATCHSTA19+00MATCH LINESEE SHEET:STA:C7.219+00SCALE: 1"=50'
0 20 5010LINEMATCHSTA28+00MATCH LINESEE SHEET:STA:C7.028+00Know what's
before you dig.
ALS
JEP
WATERLINE 1 PLAN & PROFILE
C7.1
Please add a note to this sheet stating that
at the time of City approval of these plans,
the railroad has not yet given permission for
this water line to cross railroad right-of-way.
The note should also state that City
approval of these plans does not constitute
approval of any work within railroad
right-of-way. Please call out this section of
water line as not to be constructed before
permission has been given by the railroad.
City of Fort Collins
Development Review Engineering
Sophie Buckingham, EI
Date:08/31/2022
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C8.0-C8.2_Irrigation P&P_F1.dwg - Jared Licht - 8/17/2022Init.# Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
08.17.2022
HFH000022
KEYMAP
SCALE: 1"=50'
0 20 5010
Know what's
before you dig.
ALS
JEP
IRRIGATION 1 PLAN & PROFILE
C8.0
LEGEND:
NOTES:
1. ALL UTILITY LOCATIONS SHOWN ARE BASED ON MAPS PROVIDED BY THE APPROPRIATE UTILITY COMPANY
AND FIELD SURFACE EVIDENCE AT THE TIME OF SURVEY AND IS TO BE CONSIDERED AN APPROXIMATE
LOCATION ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL
UTILITIES, PUBLIC OR PRIVATE, WHETHER SHOWN ON THE PLANS OR NOT, PRIOR TO CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO CONSTRUCTION.
2. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. LAYING
LENGTH INCLUDES FLARED END SECTIONS.
3. RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC
RIGHTS-OF-WAY SHALL BE GOVERNED BY THE TOWN OF TIMNATH. ALTERNATES (SUCH AS ADS N-12 OR HP
SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL
BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM
F477 / D3212 FOR PLASTIC PIPE).
4. ALL STORM MANHOLES LOCATED IN SIDEWALKS AND TRAILS SHALL HAVE PEDESTRIAN RATED LIDS.
5. MANHOLE DIAMETERS SHOWN ARE PER CITY STANDARDS. CONTRACTOR SHALL VERIFY THAT MANHOLE
DIAMETERS ARE SUFFICIENT FOR INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.) OR 1' FROM
PIPE O.D. TO PIPE O.D. ON MANHOLE INSIDE FACE.
6. PROVIDE WATER TIGHT JOINTS PER ASTM C443 AT ALL CIRCULAR STORM PIPE.
7. MANHOLES SHALL BE SHAPED UNLESS OTHERWISE NOTED. REFER TO PLAN VIEW FOR SHAPED MANHOLES.
8. THE PLUMBING CONTRACTOR SHALL TERMINATE UTILITY LATERALS 5' OUTSIDE OF BUILDING UNLESS
OTHERWISE NOTED. EXACT LOCATIONS (HORIZONTAL AND VERTICAL) OF ALL UTILITY CONNECTIONS INTO
THE PROPOSED BUILDING SHALL BE COORDINATED WITH THE APPROVED ARCHITECTURAL DRAWINGS.
9. CONTRACTOR TO FIELD VERIFY EXISTING INVERT ELEVATIONS AND REPORT ANY DISCREPANCIES TO THE
ENGINEER PRIOR TO CONSTRUCTION.
10. SEE SHEETS C8.3 AND C8.4 FOR IRRIGATION STRUCTURE DETAILS.
11. BOOSTER PUMPS SHALL NOT BE USED FOR IRRIGATION SYSTEMS.
12. IF NOTED AS SINGLE TAP WATER METER SHALL BE 3/4".
13. THE MINIMUM COVER OVER WATER LINES IS 5 FEET AND THE MAXIMUM COVER IS 6 FEET UNLESS OTHERWISE
NOTED IN THE PLANS AND APPROVED BY THE WATER UTILITY.
14. WATER MAINS SHALL BE C900 PVC WITH TRACER WIRE.
15. ALL WATER APPURTENANCES TO BE MECHANICALLY RESTRAINED. SEE NORTH WELD COUNTY WATER
DISTRICT VERTICAL AND HORIZONTAL BEND RESTRAINT DETAILS ON SHEET C8.2.
17. WATER TAPS SHALL BE 1" TO METER PIT AND 3/4" METER PIT TO RESIDENCE, FOR DOUBLE METER
CONDITIONS UNLESS OTHERWISE NOTED.
18. SEE DETAIL SHEET C8.5 FOR DOUBLE METER PIT DETAIL.
19. BACKFLOW PREVENTION DEVICES ARE REQUIRED ON ALL WATER SERVICES, REGARDLESS OF TYPE OR
HAZARD.
PROPOSED STORM INLET
EASEMENT LINE
PROPOSED LOTLINE
PROPOSED RIGHT-OF-WAY
PROPERTY BOUNDARY
PROPOSED CURB & GUTTER
EXISTING STORM SEWER
PROPOSED STORM SEWER
PROPOSED FIRE HYDRANT
EXISTING SANITARY SEWER
PROPOSED SANITARY SEWER
EXISTING WATER MAIN
PROPOSED WATER MAIN 8"W
8"SS
4900PROPOSED MAJOR CONTOUR
16"W
SS
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
44PROPOSED MINOR CONTOUR
4552
4550
PROPOSED MANHOLE
EXISTING IRRIGATION
EXISTING FIBER OPTIC
IRR
FO
EXISTING GAS
EXISTING UNDERGROUND ELECTRIC UE
G
PROPOSED PIPE ENCASEMENT
Please add a note to this sheet stating
that at the time of City approval of these
plans, the railroad has not yet given
permission for this irrigation line to cross
railroad right-of-way. The note should also
state that City approval of these plans
does not constitute approval of any work
within railroad right-of-way. Please call out
this section of irrigation line as not to be
constructed before permission has been
given by the railroad.
City of Fort Collins
Development Review Engineering
Sophie Buckingham, EI
Date:08/31/2022