HomeMy WebLinkAboutBLOOM FILING ONE - PDP210014 - REPORTS - DRAINAGE REPORTPREPARED FOR:
Hartford Homes, LLC
4801 Goodman St.
Timnath, CO 80547
PREPARED BY:
Galloway & Company, Inc.
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
Contact: James Prelog, PE
DATE:
March 30, 2022
Revised June 1, 2022
Revised July 13, 2022
Revised August 16, 2022
BLOOM FILING 1
Fort Collins, CO
FINAL DRAINAGE REPORT
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 2 of 28
I. Introduction........................................................................................................................................... 3
General Location ......................................................................................................................... 3
Existing Site Info ......................................................................................................................... 3
II. Master Drainage Basin ........................................................................................................................ 4
Overall Basin Description ............................................................................................................ 4
Existing Drainage Facilities ......................................................................................................... 4
Floodplain ................................................................................................................................... 5
III. Project Description .............................................................................................................................. 5
Existing Conditions...................................................................................................................... 6
Proposed Conditions ................................................................................................................... 6
IV. Proposed Drainage Facilities .............................................................................................................. 7
General Concept ......................................................................................................................... 7
Proposed Drainage Basins .......................................................................................................... 8
Detention Pond ........................................................................................................................... 9
Water Quality ............................................................................................................................ 10
LID ............................................................................................................................................ 10
V. Drainage Design Criteria ................................................................................................................... 11
Directly Connected Impervious Area (DCIA) .............................................................................. 11
Development Criteria Reference and Constraints ...................................................................... 12
Hydrological Criteria .................................................................................................................. 13
Hydraulic Criteria ...................................................................................................................... 14
VI.EROSION AND SEDIMENT CONTROL MEASURES.................................................................. 16
Construction Material & Equipment ........................................................................................... 16
Maintenance ............................................................................................................................. 16
VII. Conclusions .................................................................................................................................... 17
Compliance with Standards ....................................................................................................... 17
Variances .................................................................................................................................. 17
Summary of Concepts ............................................................................................................... 17
VIII. References ..................................................................................................................................... 18
Appendices:
A. Exhibits and Figures
B. Excerpts from Reference Materials
C. Hydrologic Computations
D. Hydraulic Computations
E. SWMM Model
F. Drainage Maps
TABLE OF CONTENTS
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 3 of 28
I. Introduction
General Location
The proposed Bloom subdivision is located directly south of East Vine Drive and north of East Mulberry
Street, just west of I-25, to the east of the Mosaic Subdivision in Fort Collins, Colorado. The overall Bloom
development is bordered to the north by East Vine Drive; to the east by the Imu-Tek Animal Health Clinic
and undeveloped land; to the south by East Mulberry Street; and to the west by East Ridge Second
Filing, also referred to as the Mosaic Subdivision. The project site is located in the Northwest Quarter of
Section 9, Township 7 N., Range 66 W. of the 6th P.M., City of Fort Collins, County of Larimer, State of
Colorado. A vicinity map is included in Appendix A for reference.
Existing Site Info
The project site consists of approximately 260 acres of vacant and undeveloped tract of land that is
currently being used for farming. Existing grades across the site vary from 0.5 to 3 percent. The site
generally drains from north to south. There are existing train tracks across the northern portion of the site
that run diagonal from the northwest to the southeast. The project site is located within the Cooper
Slough/Boxelder Basin and the Cooper Slough channel is located just to the east of the project site. The
Lake Canal also cuts across the southwest corner of the site.
According to the Natural Resources Conservation (NRCS) Web Soil Survey, the project site consists of a
mix of soil types and Hydrologic Soil Groups (HSG) including:
- Ascalon Sandy Loam (33%), HSG ‘B’
- Fort Collins Loam (27%), HSG ‘C’
- Garrett Loam (23%), HSG ‘B’
And smaller percentages of various other soil types as shown on the soil map included in Appendix A.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 4 of 28
II. Master Drainage Basin
Overall Basin Description
The project site is located in the lower portion of the Cooper Slough Watershed. The master plan for this
drainage basin is currently being updated but we were able to review a copy of the plan dated February
2021. This report is titled “City of Fort Collins Upper Cooper Slough Basin Selected Plan of
Improvements” prepared by Icon Engineering, Inc. (Master Plan). The Cooper Slough drainage basin
resides in northeast Fort Collins and unincorporated Larimer County, Colorado. The Master Plan
describes it as a long and slender watershed, flowing from north to south, comprising 28 square miles
which are tributary to Box Elder Creek and the Cache la Poudre River. The watershed begins at the
confluence with Box Elder Creek (about one-half mile south of Mulberry Street and slightly west of I-25)
and proceeds north for 20-miles to Larimer County Road 80 at a location northwest of the Town of
Wellington. The basin has a maximum width of 3.9-miles at a location just south of Wellington.
Predominant land uses are characterized by farmland and open space, with development occurring
mainly in the southern portion of the watershed, near northeast Fort Collins.
The Cooper Slough watershed has been divided into upper and lower portions by the Larimer & Weld
Canal. The project site is located in the lower portion of the watershed.
The Master Plan discusses improvements to the Cooper Slough and Lake Canals including culverts
installed in Vine and Mulberry, but these improvements lie outside of the boundaries of this project and
therefore are not a part of this project. There will be no changes to the Cooper Slough or Lake Canals as
part of this project.
The proposed development to the southeast of the project site, Peakview, has included a portion of a box
culvert that will eventually divert water from the Lake Canal to the Cooper Slough. The box culvert will be
designed, constructed, plugged, and buried until future master plan culvert improvements are
constructed.
Relevant excerpts from the Master Plan have been included in Appendix B.
Existing Drainage Facilities
A historic/existing basin map was developed with this drainage report, reference Appendix D, in order to
calculate the historic runoff from the site. A SWMM model was used to determine the existing runoff and
the 2-year and 100-year runoff values from the models are included in the basin descriptions below.
According to the Master Plan, future development with the area of the site is to “Limit the release (both
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 5 of 28
peak discharge and volume) associated with future development within the Upper Cooper Slough Basin
to the 100-year existing condition release rates into the lower Cooper Slough area.”
Basin H-1 (±72 acres, Q2 = 4.0 cfs, Q100 = 26.0 cfs) is associated with the northeastern portion of the
site to the north of the Burlington Northern Railroad tracks. Runoff generally runs south toward the
railroad tracks and then is conveyed east into the Cooper Slough.
Basin H-2 (±22 acres, Q2 = 1.3 cfs, Q100 = 15.5 cfs) is associated with the northeastern portion of the
site on the south side of the Burlington Northern Railroad tracks. Runoff generally runs south into
undeveloped land.
Basin H-3 (±162 acres, Q2 = 8.7 cfs, Q100 = 52.0 cfs) is associated with the western portion of the site.
Runoff currently sheet flows south into the Lake Canal.
Basin H-4 (±6.5 acres, Q2 = 0.4 cfs, Q100 = 8.7 cfs) is associated with the southwest portion of the site.
Runoff currently sheet flows east into the adjacent property and then to the Lake Canal.
Floodplain
The Cooper Slough runs along the eastern boundary of the Bloom Filing 1 Development. According to
the Federal Emergency Management Agency (FEMA) Flood Insurance Rate Map Panels 982 (FIRM
Number 08069C0982F) effective date December 19, 2006 and Panel 984 (FIRM Number 08069C0984H)
effective date May 2, 2012 included in Appendix A, a portion of the site lies within Zone AE of the Cooper
Slough, an area subject to inundation by the 1% annual chance 100-YR flood. In Zone AE, the base flood
elevations (BFEs) have been determined.
However, a LOMR (FEMA Case No.: 17-08-1354P) became effective February 21, 2019. The LOMR was
submitted as a part of a restudy of the Boxelder and Cooper Slough prepared for the Boxelder
Stormwater Authority by Ayres Associates. The effective 100-YR floodplain encroaches on planned Pond
B and part of Pond C, as well as in a significant portion of the Bloom Development’s southern end south
of the planned Donella Drive. No development activities are planned to encroach on the effective
floodway. All elevations provided are in reference to the NAVD 1988, with Cooper Slough effective 100-
YR floodplain water surface elevations ranging between 4930.5 ft and 4960.2 ft adjacent to the Bloom
Filing 1 Development.
The development shall follow floodplain regulations stated in Chapter 10 of the City Code. All structures
shall have the elevation of the lowest floor be above regulatory flood protection elevations. It is
anticipated that no work shall commence within the floodway.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 6 of 28
This drainage report is prepared as an addendum to the floodplain use permit application that is
submitted to the City of Fort Collins, allowing for the site to be built upon approval. A separate LOMR will
be prepared that will analyze the impact of the as-built development on the effective 100-YR floodplain
and associated water surface elevations, but the LOMR is not a requirement of the City of Fort Collins.
III. Project Description
The entire Bloom development encompasses approximately 260 acres and will include the development
of both single and multi-family homes, commercial use, and associated streets, utilities, and open space.
The project site is bordered to the west by East Ridge Second Filing, also referred to as the Mosaic
Subdivision, which is a single and multi-family development; to the north by the Trail Head Subdivision,
another single-family development; to the southeast by the proposed Peakview development; and to the
south (south of Bloom) and southwest by various commercial developments.
This report summarizes the drainage facilities for Filing 1 including any channel improvements, limited
impact development best management practices and proposed water quality/detention.
Existing Conditions
Filing 1 is 66.8 acres of vacant undeveloped farming land. Existing grades of the Site generally slope from
0.5 to 3 percent.
Proposed Conditions
Filing 1 of Bloom encompasses ±66.8 acres in the northwest area of the overall development. It will
include the development of 130 single family homes, 138 town homes, associated streets, utilities, and
open space. The area of Filing 1 drains from north to south to two detention/irrigation ponds at grades of
0.5 to 4.0 percent. These two onsite ponds will outfall into another offsite pond downstream where it will
eventually outfall into the Cooper Slough. Filing 1 will also include the storm infrastructure for Greenfields
Drive and main trunk lines for the future development along with their associated ponds.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 7 of 28
IV. Proposed Drainage Facilities
General Concept
Runoff from the developed site will be conveyed via overland flow, bioretention, and curb and gutter to a
proposed storm drain system that will convey the major and minor event stormwater runoff to onsite
detention ponds. There will be (2) two ponds in Filing 1 that will provide detention and water quality for the
Site and one (1) detention pond directly east that will control release into the Cooper Slough. Pond D will
outfall into the pond off site which outfall directly into the Cooper Slough. Releases from Pond E will travel
south eventually outfalling into the Lake Canal Overflow Channel.
The ODP has divided the project site into eight large basins, one for each detention pond. Filing 1
analyzes developed Basin D and Basin E. The runoff from the basins and the sizing and release rates for
the proposed ponds have been calculated using 0.2 cfs/acre criteria. A variance is to be provided to allow
for this change instead of using the historic 2-year flow (FCSCM Criteria) as the release rate or using the
Master Drainage Plan’s 100 year historic release.
Pond D will release flows into Pond C. Pond C’s release rate will be controlled to be less than the
allowable release that was calculated. Pond C will release at or less than 25.8 cfs combined into the
Cooper Slough. Pond C will release at 21.6 cfs, less than allowable. The release rates were analyzed
using EPA SWMM 5.1. A summary of the pond volumes and release rates from the SWMM model is
included in Appendix C. Water rights are to be provided for the ponds that are storing permanent irrigation
pools (Pond D and Pond E) per State of Colorado.
Additional future ponds Pond A, Pond B, Pond G and Pond H, have been sized for their anticipated
tributary land use. These ponds are to be provide 100 Year detention and release at the site’s allowable
rate. Due to the releasing less than allowable on the upstream side, Pond C, more flow is being released
for the downstream release rate. Chart provided in Detention Pond section of this report. Water Quality
plate may be revised once the future use has been finalized with that specific filing.
Water Quality will be provided onsite through Low Impact Development (LID) practices and also within the
detention ponds. City of Fort Collins requires at least 50% of newly added impervious areas are treated
with LID’s practices.
There are no offsite basins that impact the project site.
There are no proposed improvements to the Cooper Slough associated with the development of Filing 1.
A floodplain permit is to be submitted prior to any work being done within the floodplain.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 8 of 28
Proposed Drainage Basins
Basin D
Basin D comprises of approximately 35.6 acres. This area includes single family detached and town
homes. The developed runoff within these basins will drain into separate LID features throughout the site
until eventually outfalling into the water quality detention pond. These LID features will provide the water
quality for the minor storm events and any storm event greater will be conveyed into the proposed storm
system via overflow structures.
Basin E
Basin E comprises of approximately 33.7 acres. This area includes town homes and future multi-family
development. The developed runoff within these basins will drain into separate LID features throughout
the site until eventually outfalling into the water quality detention pond. The future multi-family area which
includes sub basin, E14.1, E15.1, E19, and E26, E26.1, will need to follow LID criteria. In particular, no
less than 50% of any newly added impervious area must be treated using one or a combination of LID
techniques, and no less than 25% of any newly added pavement areas must be treated using a
permeable pavement technology.
Basin G
Basin G comprises of approximately 40.3 acres. This area includes future developed residential property
and the interior roadways of the development. This basin also includes the development of Greenfields
Drive. All of Basin G is tributary to Pond G and will be treated for water quality and store the 100-year
storm.
Basin H
Basin H comprises of approximately 16.7 acres. This area includes future developed residential property
and the interior roadways of the development. This basin also includes the development of Greenfields
Drive. All of Basin H is tributary to Pond H and will be treated for water quality and store the 100-year
storm.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 9 of 28
Detention Pond
Each pond will provide both water quality and detention. It was determined that a more appropriate
historic release rate calculation would be the 0.2 cfs / acre instead of the 2-year historic. For the 160.3
acre development releasing into the northern part of the Cooper Slough, this yields an allowable release
of 32.06 cfs. The Site’s tributary detention ponds are modeled with a 100 year volume of 4.6 ac-ft for
Pond C, 6.6 ac-ft for Pond D, and 5.1 ac-ft for Pond E. SWMM was used to route flows from each pond to
determine the sizing and release rates from each pond. The final design for the water quality detention
pond has a 40-hr drain time to allow for stormwater treatment to occur. Each pond shall completely drain
for any event that is greater than the 5-year storm within 120 hours. The flows from Pond D’s outlet
structures will connect to a future offsite pond (Pond C) and eventually outfall to the Cooper Slough.
Ponds A, B, C, G and H have been designed in its final state and will provide water quality. In future
filings, the water quality plate will be resized for the actual imperviousness that is tributary to those ponds.
The table below shows release rates and volumes.
Sizing of spillway, water quality orifice plates, water surface elevations, etc. has all been included in
Appendix D of this report.
* 0.2 cfs/acre (Pond C Release = 129 acres * 0.2 & South Release = 93 acres * 0.2)
**Total allowable release into Cooper Slough = 44.4 cfs
**Total Anticipated release into Cooper Slough = 44.0 cfs
Detention
Pond
100-year Volume
Required (From SWMM
Model)
Site
Allowable
Release Rate
Proposed Release
Rate (From SWMM
Model)
A 10.5 ac-ft / 460,000 cf 12.1 cfs
B 6.6 ac-ft / 290,000 cf 25.8 cfs*8.7 cfs 22.1 cfs**
C 4.6 ac-ft / 200,000 cf 13.6 cfs
D 6.4 ac-ft / 280,000 cf 0.75 cfs
E 5.1 ac-ft / 220,000 cf 8.8 cfs
G 9.5 ac-ft / 412,000 cf 18.6 cfs*17.6 cfs 21.9 cfs**
H 1.7 ac-ft / 74,000 cf 0.34 cfs
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 10 of 28
Water Quality
The ODP has determined that water quality and detention will be required for the development of the Site.
Required “Water Quality Capture Volume (“WQCV”) was calculated using equation 7-1 and Equation 7-2
from FCSCM.
Basin D will require 0.317 ac-ft for WQCV and Basin E will require 0.442 ac-ft respectively. The final
design for the water quality detention pond has a 40-hr drain time to allow for stormwater treatment to
occur. Flow from the outlet structure of Detention Pond D connects to a future offsite pond and eventually
outfall to the Cooper Slough. Pond E will flow south and eventually outfall into the Peakview storm
infrastructure.
LID
Permanent BMP’s are being considered in helping to allow for runoff reduction throughout the site. The
usage of bioretention is the primary BMP to be placed in landscaping areas to provide both infiltration and
filtration for the minor storm events. All LID’s will act as bioretention. For LID 1 & 2 a sand filter will be
used. This will require additional scheduled maintenance which can be found in the SWMP report with
this submittal. All other LID’s will be bioretention. The implementation of permanent BMP’s throughout the
site has met the treatment at least 50% of added impervious area, refer to Appendix D.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 11 of 28
V. Drainage Design Criteria
Directly Connected Impervious Area (DCIA)
At this final stage of the design process, we’ve developed a strategy for implementing ‘The Four-Step
Process’ for stormwater quality management. Each step is listed below and includes a brief narrative
describing the implementation strategy.
Step 1 -Employ runoff reduction practices
Developed runoff from the D & E series of basins will drain through multiple bio-retention facilities prior
to entering the on-site detention facilities. The proposed bio-retention facilities are to provide enough
depth to capture WQCV of their respective basins. They are designed to allow infiltration of the 2-year
storm event and will provide bypass in larger storm events. The design encourages settling of
sediments, filtering, and infiltration. The MHFD defines bio-retention is an
“engineered, depressed landscape area designed to capture and filter or infiltrate the water quality
capture volume (WQCV).”
Basin’s E19 and E26 consists of Future Multi-Family development and Basin E14.1, E15.1, and E26
and E26.1 will need to provide its own on-site LID at the time of its development and submittal process.
The following table is the anticipated amount of the newly added impervious area and a breakdown of
the total area treated by an EDB or an LID feature.
Description Area, acres Final Proposed
Imperviousness, %
Newly added Impervious
Area, acres
Total Site Area:69.4
Basin D Developed Area:35.7 ~51%18.2
Basin E Developed
Area(excluding Basin
E14.1, E15.1, E19 & E26):33.7 ~47%11.8
Future Residential
Basin E14.1 & E15.1
Future Multi-Family
Basin E19 & Basin E26
Area:7.56 ~70%
Treated Total:69.4 Total: 30.0 acres
39% to EDB 12.8 acres
61% to LID 18.4 acres
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 12 of 28
Step 2 -Implement BMPs that provide a Water Quality Capture Volume (WQCV)
The developed runoff from the D and E basins will drain into an Extended Detention Basin (EDB). The
MHFD defines an Extended Detention Basin as “An engineered basin with an outlet structure designed
to slowly release urban runoff over an extended time period to provide water quality benefits and control
peak flows for frequently occurring storm events. The basins are sometimes called "dry ponds" because
they are designed not to have a significant permanent pool of water remaining between storm runoff
events. Outlet structures for extended detention basins are sized to control more frequently occurring
storm events.” Note, these ponds are also to be irrigation ponds and shall have standing water.
Step 3 -Stabilize drainageways
Measures will be implemented to protect the Cooper Slough from the on-site detention pond outflows.
Step 4 -Implement site specific and other source control BMPS
Site specific considerations such as material storage and other site operations are addressed in the
Stormwater Management Plan (SWMP).
The City Rainfall Intensity-Duration-Frequency Curves as depicted in the FCSCM are utilized as the
source for all hydrologic computations associated with the development of the Site.
The Rational Method has been utilized to calculate stormwater runoff for the proposed condition sub-
basins within the Site. The coefficients tables along with frequency adjustment factors from FCSCM have
been utilized in support of these calculations.
Development Criteria Reference and Constraints
The project must release at historic rates for each drainage basin, however due to the site being located
on flat, farmland it has been determined that 0.2 cfs/acre would be a more appropriate release into the
Cooper Slough. The 2 year historic release rate from the proposed basin delineation which includes Basin
A, B, C, D, and E is 9.69 cfs. Instead of using the calculated 2 year historic, 0.2 cfs/acre is the methodology
in determining maximum allowable release rate. This was calculated to be 25.8 cfs for the northern portion
of the site and 44.4 cfs for total site. Pond D (Filing 1) and Future Pond A and Future Pond B will connect
into Pond C which will release at a controlled rate of 21.6 cfs. Pond E (Filing 1) will flow south into the
Peakview storm infrastructure that flows into the Cooper Slough at a rate of 20.8 cfs.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 13 of 28
Hydrological Criteria
For urban catchments that are not complex and are generally 160 acres or less in size, it is acceptable that
the design storm runoff be analyzed using the Rational Method. The Rational Method is often used when
only the peak flow rate or total volume of runoff is needed (e.g., storm sewer sizing or simple detention
basin sizing). The Rational Method was used to estimate the peak flow at each design point. For preliminary
design, no routing (i.e., time attenuation) calculations were completed; this work will occur at Final Design.
When a total flow is reported within this preliminary drainage report, assume it is simply a summation of all
upstream flows.
The Rational Method is based on the Rational Formula:
Q = CiA
Where:
Q = the maximum rate of runoff, cfs
C = a runoff coefficient that is the ratio between the runoff volume from an area and the average
rate of rainfall depth over a given duration for that area
i = average intensity of rainfall in inches per hour for a duration equal to the Time of Concentration
(Tc)
A = area, acres
The one-hour rainfall Intensity-Duration-Frequency tables for use with the Rational Method of runoff
analysis are provided in Table 3.4-1 and Figure 3.4-1 (refer to Appendix B).
The 2-year and 100-year storm events are the basis for the preliminary drainage system design. The 2-
year storm is considered the minor storm event. It has a fifty percent probability of exceedance during any
given year. The 100-year storm is considered the major storm event. It has a one percent probability of
exceedance during any given year.
The 2-year drainage system, at a minimum, must be designed to transport runoff from the 2-year recurrence
interval storm event with minimal disruption to the urban environment. The 100-year drainage system, as a
minimum, must be designed to convey runoff from the 100-year recurrence interval flood to minimize life
hazards and health, damage to structures, and interruption to traffic and services.
The final detention storage was estimated with EPA SWMM 5.1. Various input parameters were provided
by Table 4.1-1 and Table 4.1.4. The total detention discharge of the site is 44.1 cfs.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 14 of 28
Hydraulic Criteria
The on-site excess developed runoff within each tributary area begins as overland flow from residential lot
areas to stormwater quality features. Runoff then flows from lots to the adjoining street section. The storm
water combines with runoff in a downstream basin or is intercepted by a sump Type ‘R’ curb inlet. These
inlets discharge to one of the onsite storm drain systems.
There are two on site storm drain systems. Portions of Storm Line D will enter a Sand Filter for water
quality treatment. Other portions will outfall into Detention Pond D and another bioretention LID to provide
water quality treatment. Segments of Storm Line E will be treated with bioretention while other portions
will outfall into Detention Pond E and provide water quality treatment.
Street Capacity Analysis
The maximum encroachment for gutter flow, within the respective street sections and during the minor
storm (Q2) event was, used to establish the street capacity for. The maximum pavement encroachment
standards presented below in Table ST-2. For example, the minor storm flows within local streets cannot
overtop the curb (dmax=0.5’) or the crown of the street. During the major storm event (Q100), the street
capacities were estimated based on the maximum street encroachment standards presented below in
Table ST-3. As an example, the depth of water, for local streets, cannot six-(6) inches at the street crown.
Street capacity calculations for two-(2) different proposed ½ street sections and a range of longitudinal
grades are presented in Appendix C.
· Vertical C&G 15’ CL to FL (Local)
· Vertical C&G 27’ CL to FL (Collector)
Table ST-2 - Pavement Encroachment Standards for the Minor Storm
Street Classification Maximum Encroachment
Local No curb overtopping. Flow may spread to crown
of street.
Collector No curb overtopping. Flow spread must leave at
least one lane free of water.
Table ST-3 - Street Inundation Standards for the Major (i.e., 100-Year) Storm
Street Classification Maximum Depth and Inundated Area
Local and Collector
The depth of water must not exceed the bottom of
the gutter at the median to allow operation of
emergency vehicles, the depth of water over the
gutter flow line shall not exceed twelve-(12)
inches, and the flow must be contained within the
right-of-way or easements paralleling the right-of-
way. The most restrictive of the three criteria shall
govern.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 15 of 28
Table ST-4 – Allowable Cross-Street Flow
Street Classification Initial Storm Flow Major (100-Year) Storm Flow
Local 6 inches of depth in cross pan.18 inches of depth above gutter
flow line.
Collector
Where cross pans allowed,
depth of flow should not exceed
6 inches.
12 inches of depth above gutter
flow line.
The minor storm event street capacity calculations were estimated with the Modified Manning Equation
and Excel. The major storm event street capacity calculations were completed using Bentley FlowMaster.
Refer to Appendix D for street capacity calculations.
Inlet Capacity Analysis
CDOT Type ‘R’ inlets are proposed throughout the project for removing excess developed runoff from the
right-of-way. The majority of these inlets are in sump. The minor and major storm event inlet capacities
were estimated with MHFD-Inlet_v5.01. The street section geometry and storm event encroachment limits
(i.e., street classification) established the maximum allowable ponding depth. We determined the inlet
length using the rational method flows at the respective design point and the maximum allowable ponding
depth. Appendix D includes capacity calculations for proposed Type ‘R’ curb inlets, which range in length
from 5’ to 20’.
Storm Drain Capacity Analysis
The storm drain system hydraulic analysis was completed using Bentley StormCAD V8i. This software
routes flows through each system by looking at the longest upstream tc at the manhole, calculating the
intensity and multiplying it by the upstream CA. Detailed output for each storm drain system analysis is
included in Appendix D.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 16 of 28
VI. EROSION AND SEDIMENT CONTROL MEASURES
A General Permit for Stormwater Discharge Associated with Construction Activities issued by the
Colorado Department of Public Health and Environment (CDPHE), Water Quality Control Division
(WQCD), will be acquired for the site. A Stormwater Management Plan (SWMP) should be prepared to
identity the Best Management Practices (BMPs) which, when implemented, will meet the requirements of
said General Permit. Below is a summary of SWMP requirements which may be implemented on-site.
The following temporary BMPs may be installed and maintained to control on-site erosion and prevent
sediment from traveling off-site during construction:
· Silt Fence – a woven synthetic fabric that filters runoff. The silt fence is a temporary barrier that is
placed at the base of a disturbed area.
· Vehicle Tracking Control – a stabilized stone pad located at points of ingress and egress on a
construction site. The stone pad is designed to reduce the amount of mud transported onto public
roads by construction traffic.
· Straw Wattles – wattles act as a sediment filter. They are a temporary BMP and require proper
installation and maintenance to ensure their performance.
· Inlet protection – Inlet protection will be used on all existing and proposed storm inlets to help prevent
debris from entering the storm sewer system. Inlet protection generally consists of straw wattles or
block and gravel filters.
Construction Material & Equipment
The contractor shall store all construction materials and equipment and shall provide maintenance and
fueling of equipment in confined areas on-site from which runoff will be contained and filtered.
Maintenance
The temporary BMPs will be inspected by the contractor at a minimum of once every two weeks and after
each significant storm event.
The property owner will be responsible for routine and non-routine maintenance of the temporary BMPs.
Routine maintenance includes:
· Remove sediment from the bottom of the temporary sediment basin when accumulated sediment
occupies about 20% of the design volume or when sediment accumulation results in poor
drainage.
· Lawn mowing-maintain height of grass depending on aesthetic requirements.
· Debris and litter removal-remove debris and litter to minimize outlet clogging and improve
aesthetics as necessary.
· Inspection of the facility-inspect the facility annually to ensure that it functions as initially intended.
· Cleaning and repair of BMP’s is required when sediment has built up or the BMP is not working
properly.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 17 of 28
VII. Conclusions
Compliance with Standards
The design presented in this drainage report for the Bloom development has been prepared in
accordance with the design standards and guidelines presented in the Fort Collins Stormwater Criteria
Manual.
Variances
1) Ch.6.1.1 Typical Release Rates: Allowable release rates during the 100-year storm event are limited
to the 2-year historic release rate, or less, as specially prescribed in the applicable Master Drainage
Plan.
Due to the site being existing farmland and relatively flat, the 2-year historic flow rates produce an
allowable flow rate of nearly 3.5 times less than the 0.2 cfs / acre criteria. Per the Master Drainage Plan, it
is stated to limit release into the lower Cooper Slough Area at the 100-year existing condition rate. The
adjacent development outfalling into the Cooper Slough is releasing in accordance with the 0.2 cfs / acre
criteria. It was also suggested per City Stormwater Engineering that flows outfalling further upstream will
help promote the hydraulic health of the Cooper Slough.
Summary of Concepts
The proposed storm drainage improvements should provide adequate protection for the developed site.
The proposed drainage system for the site should not negatively impact the existing downstream storm
drainage system.
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.Page 18 of 28
VIII. References
1.Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, January 2016
(with current revisions).
2.Fort Collins Stormwater Criteria Manual (Addendum to the Urban Drainage Storm Drainage
Criteria Manuals Volumes 1, 2, and 3),prepared by City of Fort Collins, Revised December 2018
3. Soil Map – Larimer County Area, Colorado as available through the Natural Resources
Conservation Service National Cooperative Soil Survey web site via Web Soil Survey 2.0.
4. Flood Insurance Rate Map – Larimer County, Colorado and Incorporated Areas Community
Panel No. 08069C0982F, Effective December 19, 2006 and 08069C0984H, Effective May 2,
2012.
5.City of Fort Collins Upper Cooper Slough Basin Selected Plan of Improvements, Icon
Engineering, Inc., February 2021.
6.Final Drainage Report for Peakview,United Civil Design Group, December 21, 2020.
7.Master Drainage Report for Mulberry, Galloway & Company, Inc., August 8, 2021
Bloom Filing 1
Final Drainage Report
Galloway & Company, Inc.
APPENDIX A
Exhibits and Figures
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300 •GallowayUS.com
VICINITY MAP
MULBERRY DEVELOPMENT
NOT TO SCALE
Hydrologic Soil Group—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
3/18/2021
Page 1 of 444922004492400449260044928004493000449320044934004493600449380044940004492200449240044926004492800449300044932004493400449360044938004494000498000498200498400498600498800499000499200499400
498000 498200 498400 498600 498800 499000 499200 499400
40° 35' 50'' N 105° 1' 26'' W40° 35' 50'' N105° 0' 24'' W40° 34' 47'' N
105° 1' 26'' W40° 34' 47'' N
105° 0' 24'' WN
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84
0 450 900 1800 2700
Feet
0 100 200 400 600
Meters
Map Scale: 1:9,430 if printed on A portrait (8.5" x 11") sheet.
Soil Map may not be valid at this scale.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)
Area of Interest (AOI)
Soils
Soil Rating Polygons
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Lines
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Soil Rating Points
A
A/D
B
B/D
C
C/D
D
Not rated or not available
Water Features
Streams and Canals
Transportation
Rails
Interstate Highways
US Routes
Major Roads
Local Roads
Background
Aerial Photography
The soil surveys that comprise your AOI were mapped at
1:24,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can cause
misunderstanding of the detail of mapping and accuracy of soil
line placement. The maps do not show the small areas of
contrasting soils that could have been shown at a more detailed
scale.
Please rely on the bar scale on each map sheet for map
measurements.
Source of Map: Natural Resources Conservation Service
Web Soil Survey URL:
Coordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercator
projection, which preserves direction and shape but distorts
distance and area. A projection that preserves area, such as the
Albers equal-area conic projection, should be used if more
accurate calculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as
of the version date(s) listed below.
Soil Survey Area: Larimer County Area, Colorado
Survey Area Data: Version 15, Jun 9, 2020
Soil map units are labeled (as space allows) for map scales
1:50,000 or larger.
Date(s) aerial images were photographed: Jul 19, 2018—Aug
12, 2018
The orthophoto or other base map on which the soil lines were
compiled and digitized probably differs from the background
imagery displayed on these maps. As a result, some minor
shifting of map unit boundaries may be evident.
Hydrologic Soil Group—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
3/18/2021
Page 2 of 4
Hydrologic Soil Group
Map unit symbol Map unit name Rating Acres in AOI Percent of AOI
7 Ascalon sandy loam, 0
to 3 percent slopes
B 79.5 32.7%
8 Ascalon sandy loam, 3
to 5 percent slopes
B 6.1 2.5%
22 Caruso clay loam, 0 to 1
percent slope
D 0.5 0.2%
35 Fort Collins loam, 0 to 3
percent slopes
C 66.7 27.4%
36 Fort Collins loam, 3 to 5
percent slopes
C 7.4 3.0%
37 Fort Collins loam, 5 to 9
percent slopes
C 2.9 1.2%
40 Garrett loam, 0 to 1
percent slopes
B 56.2 23.1%
42 Gravel pits A 0.0 0.0%
53 Kim loam, 1 to 3 percent
slopes
B 11.7 4.8%
76 Nunn clay loam, wet, 1
to 3 percent slopes
C 0.4 0.1%
77 Otero sandy loam, 0 to 3
percent slopes
A 9.7 4.0%
81 Paoli fine sandy loam, 0
to 1 percent slopes
A 1.0 0.4%
94 Satanta loam, 0 to 1
percent slopes
C 0.1 0.1%
103 Stoneham loam, 5 to 9
percent slopes
B 1.3 0.5%
Totals for Area of Interest 243.5 100.0%
Hydrologic Soil Group—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
3/18/2021
Page 3 of 4
Description
Hydrologic soil groups are based on estimates of runoff potential. Soils are
assigned to one of four groups according to the rate of water infiltration when the
soils are not protected by vegetation, are thoroughly wet, and receive
precipitation from long-duration storms.
The soils in the United States are assigned to four groups (A, B, C, and D) and
three dual classes (A/D, B/D, and C/D). The groups are defined as follows:
Group A. Soils having a high infiltration rate (low runoff potential) when
thoroughly wet. These consist mainly of deep, well drained to excessively
drained sands or gravelly sands. These soils have a high rate of water
transmission.
Group B. Soils having a moderate infiltration rate when thoroughly wet. These
consist chiefly of moderately deep or deep, moderately well drained or well
drained soils that have moderately fine texture to moderately coarse texture.
These soils have a moderate rate of water transmission.
Group C. Soils having a slow infiltration rate when thoroughly wet. These consist
chiefly of soils having a layer that impedes the downward movement of water or
soils of moderately fine texture or fine texture. These soils have a slow rate of
water transmission.
Group D. Soils having a very slow infiltration rate (high runoff potential) when
thoroughly wet. These consist chiefly of clays that have a high shrink-swell
potential, soils that have a high water table, soils that have a claypan or clay
layer at or near the surface, and soils that are shallow over nearly impervious
material. These soils have a very slow rate of water transmission.
If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is
for drained areas and the second is for undrained areas. Only the soils that in
their natural condition are in group D are assigned to dual classes.
Rating Options
Aggregation Method: Dominant Condition
Component Percent Cutoff: None Specified
Tie-break Rule: Higher
Hydrologic Soil Group—Larimer County Area, Colorado
Natural Resources
Conservation Service
Web Soil Survey
National Cooperative Soil Survey
3/18/2021
Page 4 of 4
FLOOD HAZARD INFORMATION
NATIONAL FLOOD INSURANCE PROGRAMFLOOD INSURANCE RATE MAP
LARIMER COUNT Y, COLORADOand Incorporated Areas
Panel Contains:
COMMUNITY NUMBER PANEL SUFFIX
09840984 JJLARIMER COUNTYFORT COLLINS, CITY OF 080101080102
MAP NUMBER08069C0984J
VERSION NUMBER2.6.4.6
SCALE
0983 1003
0992
0982
1011
0981 1001
1000*
0984
0 1,000 2,000500feet
1 inch = 500 feet 1:6,000
Map Projection:
LARIMER COUNTY
0 250 500125meters
PANEL LOCATOR
* PANEL NOT PRINTED
NOTES TO USERS))))))))))))))))
ÑÑÑ ÑÑÑ ÑÑÑ ÑÑÑ
Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ
Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ
Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ
Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑ Ñ
Ñ
ÑÑÑÑÑÑ
Larimer CountyUnincorporated Areas080101
Larimer County Unincorporated Areas 080101
Larimer County Unincorporated Areas 080101
City of Fort Collins 080102
City of Fort Collins 080102
City of Fort Collins 080102
City of Fort Collins 080102
City of Fort Collins 080102
City of Fort Collins 080102
4 9 0 349034905
4 8 9 2
48814 8 9 3
4900.5
4 8 9 9 .3
4930.7
4898.1
,D
4917.5
,E
4897.14893.04888.04883.5
,B
,X
4913.0
4945.6
4902.5
,C B
,A A
,P
,A4896.1
4923.1
,A
4913.6
4894.44919.9
4 8 9 3 .2
4900.3
,K
,D
4903.7
,O
4918.9
4920.7
4892.84928.3
,C
,B
4 9 2 0 .5
4
8
9
2.94894.0,C4892.3,H
,Y4909.14945.7
4902.7,Q
4895.7
4930.5
,A,N
4924.8
4909.04905.2
4 9 4 2 .0
,W
4937.7
4930.5
4 9 2 3 .0
4 8 9 8 .6
4920.6
4893.1,C
4886.0
,Z
,S
4894.4
4949.2
,V
4 8 9 8 .5
,R
,B
,E
4889.7
,B
4923.6
,F,CC
,J
,D
,B4896.74
9
0
9.7
,D
4900.0 4916.94916.9
,M
4902.3
4887.0
,C4902.1 4895.6,B ,T
,I4914.3
,F
,E
,C
4 8 9 8 .44892.7,C4895.7
4923.1
4900.9,A 4909.04883.3
4939.1
4916.9
4894.7
4892.3,U4894.3
Control Structure
Bridge
Bridge
Bridge
Bridge1 PCT AnnualChance Flood Discharge Contained in Structure
1 PCT Annual Chance Flood Discharge Contained in Structure
1 PCT Annual Chance Flood Discharge Contained in Structure
Culvert
Culvert
Cache La Poudre River- RProspect SFP
Cache LaPoudre River
Cache LaPoudre River- LPATH SFP
Cache La Poudre River Cooper SloughCooper Slough
Boxelder Creek
Boxelder Creek
Lake Canal
Cache La Poudre Reservoir Inlet
Lake CanalBox-elder Creek
Cache La Poudre River Reservoir Inlet
Cache La Poudre River Split - R Path
Box-elder Creek
Cooper Slough Overflow
Sherry Drive Overflow
Spring Creek
15
22
8
16
20
9
17
21
10
MAP AREA SHOW NON THIS PANEL ISLOCATED W ITHINTOWNSHIP 7 NORTH,RANGE 68 W EST.N TIMBERLINE RDGREENFIELDS CTE L I N C O L N A V E
JOHN DEERE DR
DONELLA CT ZEPPELINWAYSTIMBERLINERDSEFRONTAGERDINTERNATIONAL BLVD
E LOCUST ST
S W F R O N T A G E R DHORIZON AVEJENNIE DR
COUNTRY-SIDE DR
COUNTRY-SIDE CT
CRUSADER ST
RELIANT ST
VERDE AVEE MULBERRY ST EB
T
R
A
C
E
Y
P
K
WY
SE FRON-TAGE RDNEFRONTAGERDHARVESTER CT
P
L
E
A
S
A
N
T
A
C
R
E
S
D
R
E LINCOLN AVE
GREENBRIAR DR
¦25
WEICKER DR
DARREN CT
COMET ST
DASSAULT STCOLLINS AIRE LN
CLIFFORD CTTIGERCATWAY REDMAN DR
GREENBRIAR DRNWFRONTAGERDCOUNTRYSIDE DR
ANNABEL AVE SUPERCUB LN
DELOZIER RDLAKE CANAL CT
RIVERBENDDRCRUSADER ST
CONQUESTST
RIVERBEND CT S SUMMIT VIEW DRTANA DR
CENTRO WAYCHERLY ST
LAURA LN
FRONTAGE RD N
RENE DRMAX ST
KIMBERLY DRCOLEMAN ST
FRONTAGE RD S
¦25
BOXELDER DR
E PROSPECT RD
S
S
U
M
MIT
VIE
W
D
RSUNRISE AVE¦25
STEVEN DR
GREENFIELDS CTRAILROADQUINBY STMARQUISE ST
JOHN DEERE DRCANAL DR
FRONTAGE RD S
KENWOOD DR
BUCKEYE ST
E MULBERRY ST WB
TERRY DR
DARREN ST
SURREY LNDAWN AVESYKESDR
COMET ST
SW FRONTAGE RD
A
L
A
N S
T
SMITHFIELD DRVICOTWAYJAY DR
MARCH CTANDREASTSHARP POINT DR CLIFFORD DRJOANNE STSUMMIT CTFAIRCHILD STDELOZIER DRCONQ-UEST WAY
STOCKTON AVE
COUN-TRYS-IDE CIR
SW FRONTAGE RDSHERRY DRZONE AE
ZONE AE
ZONEAE
ZONE AE
ZONE AE(EL 4891)ZONE AE
ZONE AE
ZONE AE
ZONE AO(DEPTH 2)
ZONE AO(DEPTH 1)
ZONE AE
ZONE AE
ZONE AE
ZONE AE
ZONE AE
ZONE AE
ZONE AO (DEPTH 2)
ZONE AE
ZONE AE
ZONE AE
ZONE AE
LIMIT OF STUDY
105° 00' 00''40° 33' 45''40° 33' 45''
40° 35' 38''105° 01' 52''
105° 01' 52''
40° 35' 38''105° 00' 00''
1450000 FT
1455000 FT
3135000 FT
1450000 FT
1455000 FT
4493000m N
4492000m N
4491000m N
499000m E498000m E
PANEL 984 OF 1420
1/26/2021
Universal Transverse Mercator (UTM) Zone 13N; North American Datum 1983;Western Hemisphere; Vertical Datum: NAVD 88
SPECIAL FLOODHAZARD AREAS
OTHER AREAS OFFLOOD HAZARD
OTHERAREAS
GENERALSTRUCTURES
Without Base Flood Elevation (BFE)
With BFE or Depth
Regulator y Floodway
Area of Undetermined Flood Hazard
Area of Minimal Flood Hazard
Zone A,V, A99 Zone AE, AO, AH, VE, AR
Zone X
Zone D
HTTPS://MSC.FEMA.GOV
THE INFORMATION DEPICTED ON THIS MAP AND SUPPORTINGDOCUMENTATION ARE ALSO AVAILABLE IN DIGITAL FORMAT AT
SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT
Cross Sections with 1% Annual ChanceWater Sur face Elevation
Coastal Transect
OTHERFEATURES
Prof ile BaselineHydrographic FeatureBase Flood Elevation Line (BFE)Limit of StudyJurisdiction Boundary
Coastal Tr ansect Baseline
17.5
0.2% Annual Chance Flood Hazard, Areas of 1% annual chance f lood with average depth less than one foot or with drainage areas of less than one square mileFuture Conditions 1% Annual Chance Flood HazardArea with Reduced Flood Risk due to LeveeSee Notes.
Zone X
Zone X
Zone X
!(8
%,E 18.2
NO SCREEN
Levee, Dike, or Floodwall
Channel, Culver t, or Storm Sewer
Area with Flood Risk due to Levee Zone D
For information and questions about this Flood Insurance Rate Map (FIRM), available products associated withthis FIRM, including historic versions, the current map date for each FIRM panel, how to order products, or theNational Flood Insurance Program (NFIP) in general, please call the FEMA Mapping and Insurance eXchange at1-877-FEMA-MAP (1-877-336-2627) or visit the FEMA Flood Map Service Center website athttps://msc.fema.gov. Available products may include previously issued Letters of Map Change, a FloodInsurance Study Report, and/or digital versions of this map. Many of these products can be ordered or obtaineddirectly from the website.
Communities annexing land on adjacent FIRM panels must obtain a current copy of the adjacent panel as well asthe current FIRM Index. These may be ordered directly from the Flood Map Service Center at the number listedabove.
For community and countywide map dates refer to the Flood Insurance Study Report for this jurisdiction.
To determine if flood insurance is available in this community, contact your Insurance agent or call the NationalFlood Insurance Program at 1-800-638-6620.
Base map information shown on this FIRM was derived from the National Flood Hazard Layer (NFHL), dated2013 and digital data provided by Larimer County GIS Department, dated 2018.
PRELIMINARY1/26/2021
MAP REVISED
Bloom Filing 1
Final Drainage Report
APPENDIX B
Excerpts from Reference Materials
ANHEUSER BUSCH (AB)
PLANT
Sod Farm Diversion
Q diverted = 752 cfs
Proposed Sod Farm Pond
S = 164 AF
Max WSE = 5033.2 ft
Berm along southern end at 5037.0 ft
Sod Farm Pond Outlet Pipe
into No. 8 Outlet Ditch
36" RCP with a 33.6" Orifice
Q = 54 cfs
Mountain Vista Diversion
From No8 Outlet Ditch
Q = 250 cfsQ
=
8
9
c
f
s
Assume Full Development
of AB Lands with 100yr ->
2yr Detention (On-Site)
Mountain Vista Diversion
May Be Conveyed In
Open Channel or Pipe through
Montava Development
Proposed C&S/ Crumb
Detention Pond (426)
S = 193 AF
WSE = 4987.0 ft
Qin = 903 cfs
New AB Pond Outfall
Overflow Flume
Discharges into Cooper Slough
Q = 304 cfs
Existing AB 425 Pond Outlet
Remains Connected to L&W Canal
Q = 385 cfs
Existing AB Pond 425
S = 47 AF
Max WSE = 4983.5
Qin = 732 cfs
Remove Existing Flow Spill At CSRR
Provide Open Channel to Convey
Flows on West Side of RR
Combined Outlow From
C&S/ Crumb and L&W Canal Spill
Q = 639 cfs
Proposed E. Vine Dr. Culverts
(3) 8' x 4' RCBC
Q = 678 cfs
Proposed E. Mulberry St. Culverts
(2) 6' x 11' RCBC
Q = 1050 cfsCOOPER SLOUGHCanal Spill to Dry Creek
Q = 0 cfs
Canal Spill
Q = 421 cfsQ = 778 cfsQ = 357 cfsQ
=
2
2
9
c
f
sQ = 339 cfsQ =
1002
c
fs
Q = 374 cfsNO. 8 OUTLET DITCHLARI
M
E
R
&
W
E
L
D
C
A
N
A
LCOLORADO & SOUTHERN RAILROADBOXELDER WATERSHED
DRY CREEK WATERSHED
COOPER SLOUGH WATERSHED
BLACK HOLLOW OUTFALL CHANNEL
IMPROVEMENTS FROM 2006 MASTER
PLAN NOT INCLUDED IN 2021 UPDATE
Q
=
2
5
0
c
f
s
N. Poudre Reservoir No. 6
Add 8-inch Iron Sill Plate to
Spillway
Q = 547 cfs
S = 679 AF
Max WSE = 5163.2'
Proposed (2) 6'x11' RCBC
to Lake Canal
SH-14
Proposed Channel
to Box Elder Creek
Channel and Bank Improvements
along Cooper Slough
Pond A
S = 82 AF
Max WSE = 5019.6 ft
Qout = 778 cfs
Montava Swale
Q = 778 cfs
Q = 149 cfsOverflow Pond
S = 20.3 AF
WSE = 4980.2 ft
Qin = 112 cfs
Proposed C&S/ Crumb Outfalls:
42" RCP to AB Pond = 102 cfs
3ft x 13.5ft RCBC to AB Pond
(3ft above Pond inv) = 331 cfs
Spill to Overflow Pond = 112cfs
Overflow Pond Outfall
into L&W Canal
48" RCP with a 44.4" Orifice
Qout = 103 cfs
Proposed (3) 3'x15' RCBC
under Lake Canal
Proposed Channel
Proposed culverts
for local drainage
MONTAVA
DEVELOPMENT
MT VISTA AND TIMBERLINE ROAD
MIXED-USED DEVELOPMENT
WATER'S EDGE
DEVELOPMENT
COUNTRY CLUB
RESERVE
DEVELOPMENT
Existing 24-in Culvert
Capaity = 21cfs
Culvert Crossing
(3) 10'X3' RCBC
Q = 888cfs
Proposed Channel
Formalize Spill from
Lake Canal
E VINE DR INTERSTATE 25 SBE MULBERRY ST GIDDINGS RDTURNBERRY RDRICHARDS LAKE RD
MOUNTAIN VISTA DR
E L
I
N
C
O
L
N
A
V
E
S TIMB
E
R
LI
N
E
R
D
COUNTRY CLUB RD
E COUNTY ROAD 48
§¨¦25
§¨¦25
Cooper Slough Selected Plan (2021)
Figure 3: Selected Plan Projects $
0 0.5
Miles
Legend
swale
Overflow_Pond
Pond_A
C&S_Pond
AB_Pond
CRUMB_OUTLET
Sod Farm Pond
Proposed_Channel
Proposed Culvert
Montava Dev Boundary
Waters Edge Dev Boundary
Cooper Slough Basin Boundary
MtVista
!! !! !Anheuser Busch Property
SHARED STORM 1 - PROFILESTA: 9+50 TO STA 18+50
4910
4915
4920
4925
4930
4935
4940
4945
4950
4910
4915
4920
4925
4930
4935
4940
4945
4950
9+5010+0010+5011+0011+5012+0012+5013+0013+5014+0014+5015+0015+5016+0016+5017+0017+5018+0018+50 MH DP 1-2STA: 13+19.91RIM 4929.7±INV. IN 4924.03 (N)INV. IN 4922.01 (W)INV. OUT 4921.91 (E)FES DP 1-1STA: 10+00.00RIM 4923.6±INV. IN 4921.27 (W)STUB DP 1-3STA: 17+76.48RIM 4925.3±INV. OUT 4922.94 (E)PROPOSED GRADE EXISTING GROUND
456.6 LF 30" RCP @ 0.20%
319.9 LF 30" RCP @ 0.20%
5'(W) x 8'(L)
TYPE L RIPRAP
100-YR HGLSTART BOX CULVERTSTA: 10+01.55INV. OUT 4922.69 (E)INV. OUT 4922.69 (W)137.3 LF
4'X12' BOX CULVERT @ 0.20%END BOX CULVERTSTA: 9+95.51INV. IN 4922.41 (W)9+7510+0011+0012+0013+0014+0015+0016+0017+0018+00FRONTAGE ROAD LOT 2MULBERRY ST (CO HWY 14)FRONTAGE ROADGREENFIELDS DRIVESTA: 9+75.00N: 4440.56E: 4688.12START ALIGNMENTSTUB DP 1-3STA 9+99.20N: 4469.56E: 3887.42 FES DP 1-1STA 9+84.18N: 4442.19E: 4663.17319.9 LF 30" STORM456.6 LF 30" STORM MH DP 1-2STA 10+00.00N: 4463.10E: 4343.94DP STORM 1(SEE THIS SHEET)STA: 18+00.00N: 4469.89E: 3863.90ENDALIGNMENT GD STORM 1(SEE SHEET C4.11)GD STORM 1-3(SEE SHEET C4.11)FR STORM 1(SEE SHEET C4.13)WQ STORM 1(SEE SHEET C4.13)DP STORM 1(SEE SHEET C4.13)137.3 LF 4'X12' BOX CULVERTSTART BOX CULVERTSTA 10+01.55N: 4471.61E: 3906.00 END BOX CULVERTSTA 9+95.51N: 4463.39E: 4043.05PROPOSED BOX CULVERT(SEE SHEET C7.10 FOR MORE INFO)9+75 10+00 10+50MH DP 1-2STA 10+00.00N: 4463.10E: 4343.94 21.6 LF 12" STORMOUTLET DP 1-2.1STA 10+21.62N: 4484.71E: 4344.28 FRONTAGE ROADSTA: 9+75.00N: 4438.10E: 4343.55START ALIGNMENT STA: 10+50.00N: 4513.09E: 4344.74END ALIGNMENTMULBERRY ST (CO HWY 14)DP STORM 1 - PROFILESTA: 9+50 TO STA 11+00
4910
4915
4920
4925
4930
4935
4940
4945
4950
4910
4915
4920
4925
4930
4935
4940
4945
4950
9+50 10+00 10+50 11+00OUTLET DP 1-2.1STA: 10+21.62INV. OUT 4924.46 (S)MH DP 1-2STA: 10+00.00INV. IN 4924.03 (N)INV. IN 4922.01 (W)INV. OUT 4921.91 (E)PROPOSED GRADE
EXISTING GROUND
100-YR HGL
21.6 LF 12" RCP @ 2.00%VALLEY 14 LLC12/21/2020U18024
1" = 50'
1" = 5'PEAKVIEW PLDNORTH12/23/202011:06:53 AMC:\UNITED CIVIL DROPBOX\PROJECTS\U18024 - PEAKVIEW\CADD\CP\C4.10 - STORM PLAN & PROFILES.DWGC4.10 - STORM PLAN & PROFILESSMEJRSC4.10
67STORM PLAN & PROFILE0 50'100'
SCALE: 1" = 50'
25'PREPARED FOR:JOB NUMBER
SHEET NUMBER
SHEETSOF DATE SUBMITTED:VERTICAL:
HORIZONTAL:
SCALEPRELI
MI
NA
RY
PLANSNOT F
O
R
C
O
NST
R
U
CTI
O
N
PROJ. MGR:DRAWING NAME:PATH:DESIGNER:DATE:TIME:The engineer preparing these plans will not be responsible for, or liable for, unauthorizedchanges to or uses of these plans. All changes to the plans must be in writing and mustbe approved by the preparer of these plans.NO.BYDATECAUTIONREVISIONS:CIVIL ENGINEERING & CONSULTINGUNITED CIVILDesign Group19 OLD TOWN SQUARE #238FORT COLLINS, CO 80524(970) 530-4044www.unitedcivil.com
19
CABLE TV LINEELECTRIC LINEFIBER OPTIC LINEGAS LINEGGAS METERIRRIGATION LINESANITARY MANHOLESANITARY MAINSANITARY SERVICEFLARED END SECTIONSTORM INLETSTORM MANHOLESTORM OUTLETSTRUCTURESTORM PIPERIP RAPTELEPHONE LINEFIRE HYDRANTFIRELINEWATER FITTINGS
WATER MAIN
WATER SERVICE
WATER METER
THRUST BLOCK
GATE VALVE
FIBER, GAS, ELECTRIC, ORTELEPHONE PEDESTALLEGENDNKEYMAP
1.THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE FIELD
CONDITIONS ARE AS SHOWN IN THE DRAWINGS. IF THE
CONTRACTOR FINDS DISCREPANCIES THE CONTRACTOR SHALL
CONTACT THE ENGINEER.
2.EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE
UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST
INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES
NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION.
EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT
LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR
SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC
AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT
UTILITY LOCATION.
3.THE CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS
IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS
PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES.
4.STORM SEWER SHALL BE CONSTRUCTED IN ACCORDANCE WITH
CITY OF FORT COLLINS SPECIFICATIONS AND DETAILS. SEE
ADDITIONAL NOTES ON SHEET C0.03.
5.STORM SEWER MAINS SHOWN ON THESE DRAWINGS AS HIGH
DENSITY POLYETHYLENE (HDPE) SHALL BE WATERTIGHT ADS-N12
OR APPROVED EQUAL.
6.ALL PIPE LENGTHS ARE FROM CENTER TO CENTER OF ADJACENT
STRUCTURES. DESIGN LENGTH OF THE PIPE INCLUDES THE LAYING
LENGTH OF FLARED END SECTIONS.
NOTES
CHECKED BY:CHECKED BY:CHECKED BY:APPROVED:CITY OF GREELEYREVIEWED BY:___________________________________________ LARIMER COUNTY ENGINEERING DATELARIMER COUNTY APPROVAL BLOCK NORTH
Bloom Filing 1
Final Drainage Report
APPENDIX C
Hydrologic Calculations
Tributary Area tc | 2-Year tc | 100-Year Q2 Q100
Sub-basin (acres)(min)(min)(cfs)(cfs)
D1 1.37 0.59 0.73 10.8 8.4 1.7 8.5
D2 3.29 0.59 0.74 15.9 15.9 3.6 15.5
D3 1.11 0.69 0.86 10.2 7.4 1.7 8.5
D3.1 0.71 0.60 0.75 13.2 10.7 1.3 4.0
D4 1.04 0.60 0.75 10.8 8.4 1.3 6.6
D5 1.13 0.62 0.77 12.8 10.3 1.4 6.6
D6 1.32 0.63 0.78 13.8 11.3 1.6 7.7
D7 1.57 0.62 0.78 12.8 10.3 2.0 9.4
D8 1.24 0.60 0.75 6.4 5.4 2.0 9.1
D8.1 0.17 0.79 0.99 8.1 5.0 0.3 1.7
D9 1.56 0.63 0.79 6.9 6.0 2.6 11.8
D10 0.54 0.72 0.91 7.8 5.0 1.0 4.9
D11 1.15 0.65 0.81 9.6 6.9 1.7 8.5
D12 1.48 0.64 0.80 11.6 9.4 2.0 9.4
D13 0.97 0.20 0.26 11.9 11.9 0.4 1.8
D14 0.75 0.70 0.87 6.2 5.0 1.4 6.5
D15 0.70 0.59 0.74 8.3 7.1 1.0 4.7
D15.1 0.93 0.63 0.79 10.7 9.4 1.3 5.9
D16 1.06 0.72 0.91 6.2 5.0 2.1 9.5
D17 1.07 0.72 0.90 6.2 5.0 2.1 9.6
D18 0.37 0.25 0.31 13.1 13.1 0.2 0.8
D19 0.62 0.79 0.99 13.3 11.4 1.0 4.5
D20 0.60 0.82 1.00 9.2 7.5 1.1 5.3
D21 1.60 0.19 0.23 15.1 15.1 0.6 2.4
D22 0.24 0.15 0.19 5.6 5.5 0.1 0.4
D23 0.68 0.43 0.53 9.8 8.7 0.7 3.0
D24 3.02 0.15 0.19 5.0 5.0 1.3 5.6
OS1 0.70 0.44 0.55 9.0 7.8 0.7 3.3
OS2 0.54 0.35 0.44 9.0 8.1 0.4 2.0
OS3 0.85 0.33 0.41 12.4 11.8 0.6 2.6
OS4 0.29 0.46 0.57 5.0 5.0 0.4 1.7
OS5 0.15 0.79 0.99 5.0 5.0 0.3 1.5
OS6 0.43 0.60 0.75 8.2 7.2 0.6 2.9
OS7 0.41 0.57 0.72 8.4 7.4 0.6 2.6
BASIN SUMMARY TABLE
C2 C100
H:\Hartford Homes\HFHLV0001.01 Timberline Vine Dr\3. Permit Const Docs\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-
Info\Hydrology\Rational\HFHLV0001.01_Drainage_Calcs_Template_v2.0-CoFC.xls
E1 1.07 0.72 0.90 6.6 5.0 2.0 9.6
E2 0.96 0.76 0.95 6.0 5.0 2.0 9.1
E3 0.80 0.68 0.85 10.7 9.4 1.2 5.4
E3.1 0.80 0.68 0.85 10.7 9.4 1.2 5.4
E4 0.40 0.22 0.28 10.3 9.8 0.2 0.9
E5 1.07 0.72 0.90 5.0 5.0 2.2 9.5
E6 0.63 0.68 0.85 7.9 6.8 1.1 4.9
E7 1.03 0.74 0.92 5.0 5.0 2.2 9.5
E8 0.35 0.21 0.27 10.4 9.9 0.2 0.7
E9 1.07 0.72 0.90 5.0 5.0 2.2 9.6
E10 1.03 0.74 0.93 5.0 5.0 2.2 9.5
E11 0.40 0.55 0.68 8.8 7.9 0.5 2.3
E11.1 0.34 0.68 0.85 7.9 6.7 0.6 2.7
E12 0.44 0.79 0.99 7.2 5.9 0.9 4.1
E12.1 0.21 0.94 1.00 5.0 5.0 0.6 2.1
E13 0.59 0.15 0.19 10.1 9.8 0.2 0.9
E14 0.30 0.65 0.81 8.8 6.5 0.5 2.2
E14.1 1.30 0.80 1.00 10.0 10.0 2.3 10.0
E15 0.57 0.82 1.00 14.4 12.3 0.9 4.1
E15.1 0.56 0.80 1.00 10.0 10.0 1.0 4.3
E16 1.00 0.15 0.19 14.8 14.8 0.3 1.2
E17 0.59 0.65 0.81 9.2 7.6 0.9 4.2
E17.1 0.40 0.55 0.69 10.1 8.8 0.5 2.3
E18 0.41 0.55 0.69 7.8 6.6 0.6 2.6
E19 2.72 0.80 1.00 10.0 10.0 4.8 21.0
E20 0.74 0.76 0.95 15.7 15.7 1.0 4.5
E20.1 0.23 0.76 0.96 8.5 7.0 0.4 2.0
E21 1.04 0.20 0.26 14.0 14.0 0.4 1.8
E22 0.99 0.76 0.96 5.0 5.0 0.4 9.4
E23 0.99 0.77 0.96 5.0 5.0 2.2 9.4
E24 0.73 0.54 0.67 12.8 11.6 0.8 3.6
E24.1 0.36 0.67 0.84 11.6 9.4 0.5 2.4
E25 0.74 0.78 0.98 14.0 13.3 1.1 5.0
E25.1 0.19 0.62 0.78 9.8 8.5 0.3 1.2
E26 2.39 0.80 1.00 10.0 10.0 0.3 18.5
E26.1 0.72 0.80 1.00 10.0 10.0 1.3 5.5
E27 0.33 0.69 0.86 6.5 5.0 0.6 2.9
E28 0.84 0.76 0.95 14.6 14.6 1.2 3.3
E29 1.77 0.15 0.19 5.0 5.0 0.8 3.3
E30 1.04 0.77 0.97 15.7 15.7 1.5 6.4
G1 1.15 0.79 0.99 17.1 17.1 1.6 7.0
G2 1.15 0.79 0.99 17.1 17.1 1.7 7.0
G3 1.18 0.81 1.00 16.8 16.8 1.7 7.3
G4 1.16 0.81 1.00 16.8 16.8 1.7 7.2
G5 0.34 0.77 0.96 9.0 7.6 0.6 2.9
G6 0.37 0.77 0.96 9.0 7.6 0.7 3.1
G6.1 0.45 0.77 0.96 9.0 7.6 0.8 3.8
G7.1 0.42 0.81 1.00 8.7 7.3 0.8 137.9
G7 0.46 0.78 0.98 6.8 5.4 0.9 4.4
G8 0.48 0.78 0.97 6.9 5.5 1.0 4.5
H1 0.44 0.77 0.97 7.3 5.9 0.0 4.1
H2 0.53 0.77 0.96 7.3 5.9 0.9 4.9
H3 0.92 0.80 1.00 7.3 5.8 38.6 8.8
H4 1.02 0.80 0.99 7.4 5.9 1.9 9.7
H:\Hartford Homes\HFHLV0001.01 Timberline Vine Dr\3. Permit Const Docs\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-
Info\Hydrology\Rational\HFHLV0001.01_Drainage_Calcs_Template_v2.0-CoFC.xls
FUT-A 56.00 0.80 1.00
FUT-B 15.30 0.80 1.00
FUT-C 22.00 0.80 1.00
D BASINS
(TO DETENTION)37.17 --37.3 172.1
E BASINS
(TO DETENTION)26.62 --42.2 211.0
TO LID 1 8.35 --
TO LID 2 15.33 --
TO LID 3 1.06 --
TO LID 4 1.03 --
TO LID 5 1.07 --
TO LID 6 1.07 --
TO LID 7 0.96 --
TO LID 8 1.03 --
TO LID 9 1.07 --
TO LID 10 1.03 --
TO LID 12 0.99 --
TO LID 13 0.99 --
H:\Hartford Homes\HFHLV0001.01 Timberline Vine Dr\3. Permit Const Docs\3.04 Grading-Drainage Studies\3.04.2 Proposed Drainage Reports-
Info\Hydrology\Rational\HFHLV0001.01_Drainage_Calcs_Template_v2.0-CoFC.xls
Subdivision:Mulberry Project Name:Mulberry Filing 1
Location:CO, Fort Collins Project No.:
Calculated By:MJP
Checked By:JP
INPUT User Input Date:8/3/21
OUTPUT Calculated Value Single-Family Alley-Loaded SF Duplex/AttachedMulti-Family
95%5%100%
D1 1.37 95 0.32 23 15 0.62 7 95 0.42 29 0.59
D2 3.29 95 0.64 18 15 1.47 7 95 1.18 34 0.59
D3 1.11 95 0.40 34 15 0.36 5 95 0.35 30 0.69
D3.1 0.71 95 0.19 25 15 0.31 7 95 0.21 28 0.60
D4 1.04 95 0.17 15 15 0.46 7 95 0.42 38 0.60
D5 1.13 95 0.24 20 15 0.47 6 95 0.42 35 0.62
D6 1.32 95 0.30 21 15 0.54 6 95 0.49 35 0.63
D7 1.57 95 0.23 14 15 0.65 6 95 0.70 42 0.62
D8 1.24 95 0.21 16 15 0.54 7 95 0.49 38 0.60
D8.1 0.17 95 0.14 76 15 0.03 3 95 0.00 0 0.79
D9 1.56 95 0.46 28 15 0.62 6 95 0.49 30 0.63
D10 0.54 95 0.11 19 15 0.15 4 95 0.28 49 0.72
D11 1.15 95 0.27 22 15 0.43 6 95 0.45 37 0.65
D12 1.48 95 0.27 17 15 0.58 6 95 0.63 40 0.64
D13 0.97 95 0.07 6 15 0.90 14 95 0.00 0 0.20
D14 0.75 95 0.23 30 15 0.24 5 95 0.28 35 0.70
D15 0.70 95 0.35 47 15 0.31 7 95 0.04 5 0.59
D15.1 0.93 95 0.56 57 15 0.37 6 95 0.00 0 0.63
D16 1.06 95 0.31 28 15 0.30 4 95 0.45 40 0.72
D17 1.07 95 0.31 28 15 0.31 4 95 0.45 40 0.72
D18 0.37 95 0.05 12 15 0.32 13 95 0.00 0 0.25
D18.1 2.22
Area Weighted
COMPOSITE RUNOFF COEFFICIENTS
HFH22
Area (ac)Basin ID Total Area (ac)Runoff
Coefficient
Future Clubhouse
Area
Weighted
C2Runoff
Coefficient Area (ac)
Roofs
Runoff
Coefficient Area (ac)Area
Weighted
Asphalt + Concrete Walks Lawns, Sandy Soil
Page 4 of 17 7/12/2022
95%5%100%
Area Weighted Area (ac)Basin ID Total Area (ac)Runoff
Coefficient
Area
Weighted
C2Runoff
Coefficient Area (ac)
Roofs
Runoff
Coefficient Area (ac)Area
Weighted
Asphalt + Concrete Walks Lawns, Sandy Soil
D19 0.62 95 0.50 76 15 0.12 3 95 0.00 0 0.79
D20 0.60 95 0.50 79 15 0.10 2 95 0.00 0 0.82
D21 1.60 95 0.07 4 15 1.53 14 95 0.00 0 0.19
D21.1 1.04 95 0.07 6 15 0.97 14 95 0.00 0 0.20
D22 0.24 95 0.00 0 15 0.24 15 95 0.00 0 0.15
D23 0.68 95 0.24 33 15 0.45 10 95 0.00 0 0.43
D24 3.02 95 0.00 0 15 3.02 15 95 0.00 0 0.15
OS1 0.70 95 0.25 34 15 0.45 10 95 0.00 0 0.44
OS2 0.54 95 0.13 24 15 0.41 11 95 0.00 0 0.35
OS3 0.85 95 0.19 22 15 0.66 12 95 0.00 0 0.33
OS4 0.29 95 0.11 37 15 0.18 9 95 0.00 0 0.46
OS5 0.15 95 0.12 76 15 0.03 3 95 0.00 0 0.79
OS6 0.43 95 0.24 53 15 0.19 7 95 0.00 0 0.60
OS7 0.41 95 0.22 50 15 0.19 7 95 0.00 0 0.57
EX-1 0.78 95 0.71 86 15 0.07 1 95 0.00 0 0.88
Page 5 of 17 7/12/2022
95%5%100%
Area Weighted Area (ac)Basin ID Total Area (ac)Runoff
Coefficient
Area
Weighted
C2Runoff
Coefficient Area (ac)
Roofs
Runoff
Coefficient Area (ac)Area
Weighted
Asphalt + Concrete Walks Lawns, Sandy Soil
E1 1.07 95 0.31 28 15 0.31 4 95 0.45 40 0.72
E2 0.96 95 0.31 31 15 0.23 4 95 0.42 42 0.76
E3 0.80 95 0.43 51 15 0.27 5 95 0.10 12 0.68
E3.1 0.80 95 0.43 51 15 0.27 5 95 0.10 12 0.68
E4 0.40 95 0.03 8 15 0.36 14 95 0.00 0 0.22
E5 1.07 95 0.33 30 15 0.31 4 95 0.43 38 0.72
E6 0.63 95 0.42 63 15 0.21 5 95 0.00 0 0.68
E7 1.03 95 0.33 31 15 0.27 4 95 0.43 39 0.74
E8 0.35 95 0.03 8 15 0.32 14 95 0.00 0 0.21
E9 1.07 95 0.33 30 15 0.31 4 95 0.43 38 0.72
E10 1.03 95 0.33 31 15 0.27 4 95 0.43 40 0.74
E11 0.40 95 0.20 47 15 0.20 8 95 0.00 0 0.55
E11.1 0.34 95 0.23 63 15 0.11 5 95 0.00 0 0.68
E12 0.44 95 0.35 76 15 0.09 3 95 0.00 0 0.79
E12.1 0.21 95 0.21 93 15 0.00 0 95 0.00 0 0.94
E13 0.59 95 0.00 0 15 0.59 15 95 0.00 0 0.15
E14 0.30 95 0.19 59 15 0.11 6 95 0.00 0 0.65
E14.1 1.30 0.80
E15 0.57 95 0.48 80 15 0.09 2 95 0.00 0 0.82
E15.1 0.56 95 0.47 80 15 0.09 2 95 0.00 0 0.82
E16 1.00 95 0.00 0 15 1.00 15 95 0.00 0 0.15
E17 0.59 95 0.37 59 15 0.22 6 95 0.00 0 0.65
E17.1 0.40 95 0.20 48 15 0.20 7 95 0.00 0 0.55
E18 0.41 95 0.20 48 15 0.20 7 95 0.00 0 0.55
E19 2.72 0.80
E20 0.74 95 0.57 73 15 0.18 4 95 0.00 0 0.76
E20.1 0.23 95 0.18 73 15 0.05 3 95 0.00 0 0.76
E21 1.04 95 0.07 6 15 0.97 14 95 0.00 0 0.20
E22 0.99 95 0.33 32 15 0.23 3 95 0.43 41 0.76
E23 0.99 95 0.33 32 15 0.23 3 95 0.43 41 0.77
E24 0.73 95 0.35 46 15 0.38 8 95 0.00 0 0.54
E24.1 0.36 95 0.14 38 15 0.13 5 95 0.09 24 0.67
E25 0.74 95 0.42 54 15 0.15 3 95 0.17 21 0.78
E25.1 0.19 95 0.11 56 15 0.08 6 95 0.00 0 0.62
E26 2.39 0.80
E26.1 0.72 0.80
E27 0.33 95 0.22 64 15 0.11 5 95 0.00 0 0.69
E28 0.84 95 0.64 72 15 0.20 4 95 0.00 0 0.76
E29 1.77 95 0.00 0 15 1.77 15 95 0.00 0 0.15
E30 1.04 95 0.81 74 15 0.23 3 95 0.00 0 0.77
Future Multi-Family
Future Multi-Family
Future Multi-Family
Future Multi-Family
Page 6 of 17 7/12/2022
95%5%100%
Area Weighted Area (ac)Basin ID Total Area (ac)Runoff
Coefficient
Area
Weighted
C2Runoff
Coefficient Area (ac)
Roofs
Runoff
Coefficient Area (ac)Area
Weighted
Asphalt + Concrete Walks Lawns, Sandy Soil
G1 1.15 95 0.93 76 15 0.23 3 95 0.00 0 0.79
G2 1.15 95 0.93 76 15 0.23 3 95 0.00 0 0.79
G3 1.18 95 0.97 78 15 0.21 3 95 0.00 0 0.81
G4 1.16 95 0.96 78 15 0.20 3 95 0.00 0 0.81
G5 0.34 95 0.26 73 15 0.08 3 95 0.00 0 0.77
G6 0.37 95 0.28 73 15 0.08 3 95 0.00 0 0.77
G6.1 0.45 95 0.34 73 15 0.10 3 95 0.00 0 0.77
G7.1 0.42 95 0.34 78 15 0.07 3 95 0.00 0 0.81
G7 0.46 95 0.36 75 15 0.09 3 95 0.00 0 0.78
G8 0.48 95 0.38 74 15 0.10 3 95 0.00 0 0.78
FUT-G 17.03 95 14.91 83 15 2.12 250 95 0.00 0 3.33
H1 0.44 95 0.35 74 15 0.10 3 95 0.00 0 0.77
H2 0.53 95 0.41 74 15 0.12 3 95 0.00 0 0.77
H3 0.92 95 0.75 77 15 0.17 3 95 0.00 0 0.80
H4 1.02 95 0.83 77 15 0.20 3 95 0.00 0 0.80
FUT-A 56.00 0.80
FUT-B 15.30 0.80
FUT-C 22.00 0.80
%Imp
Future Development
Future Development
Future Development
Page 7 of 17 7/12/2022
95%5%100%
Area Weighted Area (ac)Basin ID Total Area (ac)Runoff
Coefficient
Area
Weighted
C2Runoff
Coefficient Area (ac)
Roofs
Runoff
Coefficient Area (ac)Area
Weighted
Asphalt + Concrete Walks Lawns, Sandy Soil
D BASINS (Detention Tributary)37.17 48%
D Basins Total 34.25 46%
WQCV Pond D 12.34 43%
LID 1 Tributary (D1, D3.1 D3, D4,
D12, D21, D21.1)8.35 44%
LID 2 Tributary (D2, D5, D6, D8, D9,
D11, D15, D18, D22)15.33 57%
LID 3 Tributary (D17)1.06 72%
LID 4 Tributary (D16)1.07 71%
E BASINS (Detention Tributary)26.62 66%
WQCV Pond E 15.81 60%
LID 5 (Tributary E5)1.07 71%
LID 6 (Tributary E1)1.07 71%
LID 7 (Tributary E2)0.96 76%
LID 8 (Tributary E7)1.03 73%
LID 9 (Tributary E9)1.07 71%
LID 10 (Tributary E10)1.03 74%
LID 11 (Tributary E22)0.99 76%
LID 13 (Tributary E23)0.99 76%
Page 8 of 17 7/12/2022
Subdivision:Mulberry Project Name:Mulberry Filing 1
Location:CO, Fort Collins Project No.:
Calculated By:MJP
Checked By:JP
Date:8/3/21
1 2 3 4 5 6 7 8 9 10 13 15 16 17 18 19 20 21 22 23 24
BASIN D.A.Hydrologic C2 C5 C100 L S Ti | 2-Year Ti | 100-Year L S Cv VEL.Tt COMP. Tc | 2-Year COMP. Tc | 100-Year TOTAL Urbanized Tc Tc | 2-Year Tc | 100-Year
ID (AC)Soils Group Cf=1.00 Cf=1.00 Cf=1.25 (FT)(%)(MIN)(MIN)(FT)(%)(FPS)(MIN)(MIN)(MIN)LENGTH(FT)(MIN)(MIN)(MIN)
D1 1.37 B 0.59 0.59 0.73 130 2.00 8.7 6.2 325 0.50 20 2.5 2.1 10.8 8.4 455 12.5 10.8 8.4
D2 3.29 B 0.59 0.59 0.74 100 2.00 7.5 5.3 966 0.50 20 1.2 13.0 20.5 18.3 1066 15.9 15.9 15.9
D3 1.11 B 0.69 0.69 0.86 120 2.00 6.7 3.9 400 0.50 20 1.9 3.6 10.2 7.4 520 12.9 10.2 7.4
D3.1 0.71 B 0.60 0.60 0.75 120 2.00 8.2 5.8 500 0.50 20 1.7 5.0 13.2 10.7 620 13.4 13.2 10.7
D4 1.04 B 0.60 0.60 0.75 120 2.00 8.2 5.7 300 0.87 20 1.9 2.7 10.8 8.4 420 12.3 10.8 8.4
D5 1.13 B 0.62 0.62 0.77 120 2.00 7.9 5.4 480 0.67 20 1.6 4.9 12.8 10.3 600 13.3 12.8 10.3
D6 1.32 B 0.63 0.63 0.78 120 2.00 7.7 5.2 640 0.76 20 1.7 6.1 13.8 11.3 760 14.2 13.8 11.3
D7 1.57 B 0.62 0.62 0.78 120 2.00 7.8 5.3 430 0.51 20 1.4 5.0 12.8 10.3 550 13.1 12.8 10.3
D8 1.24 B 0.60 0.60 0.75 20 2.00 3.3 2.3 360 0.92 20 1.9 3.1 6.4 5.4 380 12.1 6.4 5.4
D8.1 0.17 B 0.79 0.79 0.99 120 2.00 5.0 1.8 360 0.92 20 1.9 3.1 8.1 4.9 480 12.7 8.1 5.0
D9 1.56 B 0.63 0.63 0.79 15 2.00 2.7 1.8 560 1.20 20 2.2 4.3 6.9 6.0 575 13.2 6.9 6.0
D10 0.54 B 0.72 0.72 0.91 120 2.00 6.1 3.2 160 0.63 20 1.6 1.7 7.8 4.9 280 11.6 7.8 5.0
D11 1.15 B 0.65 0.65 0.81 120 2.00 7.3 4.7 210 0.60 20 1.5 2.3 9.6 6.9 330 11.8 9.6 6.9
D12 1.48 B 0.64 0.64 0.80 90 2.00 6.5 4.3 500 0.66 20 1.6 5.1 11.6 9.4 590 13.3 11.6 9.4
D13 0.97 B 0.20 0.20 0.26 90 2.00 12.6 11.9 250 0.68 20 1.6 2.5 15.1 14.4 340 11.9 11.9 11.9
D14 0.75 B 0.70 0.70 0.87 30 2.00 3.3 1.9 250 0.50 20 1.4 2.9 6.2 4.8 280 11.6 6.2 5.0
D15 0.70 B 0.59 0.59 0.74 30 2.00 4.1 2.9 560 1.25 20 2.2 4.2 8.3 7.1 590 13.3 8.3 7.1
D15.1 0.93 B 0.63 0.63 0.79 30 2.00 3.8 2.5 780 0.50 20 1.9 6.9 10.7 9.4 810 14.5 10.7 9.4
D16 1.06 B 0.72 0.72 0.91 80 2.00 5.0 2.6 100 0.50 20 1.4 1.2 6.2 3.8 180 11.0 6.2 5.0
D17 1.07 B 0.72 0.72 0.90 80 2.00 5.0 2.6 100 0.50 20 1.4 1.2 6.2 3.8 180 11.0 6.2 5.0
D18 0.37 B 0.25 0.25 0.31 100 2.00 12.6 11.7 450 0.67 20 1.6 4.6 17.2 16.3 550 13.1 13.1 13.1
D19 0.62 B 0.79 0.79 0.99 40 2.00 2.9 1.0 950 0.58 20 1.5 10.4 13.3 11.4 990 15.5 13.3 11.4
D20 0.60 B 0.82 0.82 1.00 40 2.00 2.6 0.9 700 0.50 20 1.8 6.6 9.2 7.5 740 14.1 9.2 7.5
D21 1.60 B 0.19 0.19 0.23 300 0.50 37.3 35.4 610 0.98 20 2.0 5.1 42.4 40.5 910 15.1 15.1 15.1
D22 0.24 B 0.15 0.15 0.19 10 2.00 4.5 4.3 100 0.51 20 1.4 1.2 5.6 5.5 110 10.6 5.6 5.5
D23 0.68 B 0.43 0.43 0.53 50 2.00 7.1 6.0 300 0.86 20 1.9 2.7 9.8 8.7 350 11.9 9.8 8.7
D24 3.02 B 0.15 0.15 0.19 30 25.00 3.3 3.2 100 0.91 20 1.9 0.9 4.2 4.1 130 10.7 5.0 5.0
OS1 0.70 B 0.44 0.44 0.55 50 2.00 7.0 5.8 180 1.00 20 1.5 2.0 9.0 7.8 230 11.3 9.0 7.8
OS2 0.54 B 0.35 0.35 0.44 50 2.00 7.9 7.0 120 1.00 20 1.8 1.1 9.0 8.1 170 10.9 9.0 8.1
OS3 0.85 B 0.33 0.33 0.41 25 2.00 5.7 5.1 400 1.00 20 1.0 6.7 12.4 11.8 425 12.4 12.4 11.8
OS4 0.29 B 0.46 0.46 0.57 25 2.00 4.8 3.9 45 2.00 20 3.0 0.3 5.0 4.2 70 10.4 5.0 5.0
OS5 0.15 B 0.79 0.79 0.99 50 2.00 3.3 1.2 45 2.00 20 3.0 0.3 3.5 1.4 95 10.5 5.0 5.0
OS6 0.43 B 0.60 0.60 0.75 20 2.00 3.3 2.3 325 1.25 20 1.1 4.9 8.2 7.2 345 11.9 8.2 7.2
OS7 0.41 B 0.57 0.57 0.72 20 2.00 3.5 2.6 325 1.25 20 1.1 4.9 8.4 7.4 345 11.9 8.4 7.4
EX-1 0.78 B 0.88 0.88 1.00 20 2.00 1.5 0.7 870 0.50 20 0.7 21.4 22.9 22.0 890 14.9 14.9 14.9
DATA
STANDARD FORM SF-2
TIME OF CONCENTRATION
SUB-BASIN Tc CHECK
HFH22
FINALINITIAL/OVERLAND
(Ti)
TRAVEL TIME
(URBANIZED BASINS)(Tt)
Page 9 of 17 7/12/2022
Subdivision:Mulberry Project Name:Mulberry Filing 1
Location:CO, Fort Collins Project No.:
Calculated By:MJP
Checked By:JP
Date:8/3/21
1 2 3 4 5 6 7 8 9 10 13 15 16 17 18 19 20 21 22 23 24
BASIN D.A.Hydrologic C2 C5 C100 L S Ti | 2-Year Ti | 100-Year L S Cv VEL.Tt COMP. Tc | 2-Year COMP. Tc | 100-Year TOTAL Urbanized Tc Tc | 2-Year Tc | 100-Year
ID (AC)Soils Group Cf=1.00 Cf=1.00 Cf=1.25 (FT)(%)(MIN)(MIN)(FT)(%)(FPS)(MIN)(MIN)(MIN)LENGTH(FT)(MIN)(MIN)(MIN)
DATA
STANDARD FORM SF-2
TIME OF CONCENTRATION
SUB-BASIN Tc CHECK
HFH22
FINALINITIAL/OVERLAND
(Ti)
TRAVEL TIME
(URBANIZED BASINS)(Tt)
E1 1.07 C 0.72 0.72 0.90 80 2.00 5.1 2.7 150 0.67 20 1.6 1.5 6.6 4.2 230 11.3 6.6 5.0
E2 0.96 C 0.76 0.76 0.95 80 2.00 4.5 2.0 150 0.67 20 1.6 1.5 6.0 3.5 230 11.3 6.0 5.0
E3 0.80 C 0.68 0.68 0.85 30 2.00 3.4 2.0 585 0.44 20 1.3 7.3 10.7 9.4 615 13.4 10.7 9.4
E3.1 0.80 C 0.68 0.68 0.85 30 2.00 3.4 2.0 585 0.44 20 1.3 7.3 10.7 9.4 615 13.4 10.7 9.4
E4 0.40 C 0.22 0.22 0.28 40 2.00 8.3 7.7 250 1.04 20 2.0 2.0 10.3 9.8 290 11.6 10.3 9.8
E5 1.07 C 0.72 0.72 0.90 45 2.00 3.8 2.0 100 2.59 20 3.2 0.5 4.3 2.5 145 10.8 5.0 5.0
E6 0.63 C 0.68 0.68 0.85 20 2.00 2.8 1.7 460 0.56 20 1.5 5.1 7.9 6.8 480 12.7 7.9 6.8
E7 1.03 C 0.74 0.74 0.92 45 2.00 3.6 1.7 100 2.59 20 3.2 0.5 4.1 2.3 145 10.8 5.0 5.0
E8 0.35 C 0.21 0.21 0.27 40 2.00 8.3 7.8 250 1.04 20 2.0 2.0 10.4 9.9 290 11.6 10.4 9.9
E9 1.07 C 0.72 0.72 0.90 45 2.00 3.8 2.0 100 2.59 20 3.2 0.5 4.3 2.5 145 10.8 5.0 5.0
E10 1.03 C 0.74 0.74 0.93 45 2.00 3.6 1.7 100 2.59 20 3.2 0.5 4.1 2.2 145 10.8 5.0 5.0
E11 0.40 C 0.55 0.55 0.68 20 2.00 3.7 2.8 460 0.56 20 1.5 5.1 8.8 7.9 480 12.7 8.8 7.9
E11.1 0.34 C 0.68 0.68 0.85 20 2.00 2.8 1.6 460 0.56 20 1.5 5.1 7.9 6.7 480 12.7 7.9 6.7
E12 0.44 C 0.79 0.79 0.99 20 2.00 2.1 0.8 460 0.56 20 1.5 5.1 7.2 5.9 480 12.7 7.2 5.9
E12.1 0.21 C 0.94 0.94 1.00 20 2.00 1.1 0.7 200 1.30 20 2.3 1.5 2.6 2.1 220 11.2 5.0 5.0
E13 0.59 C 0.15 0.15 0.19 20 2.00 6.3 6.1 375 0.69 20 1.7 3.8 10.1 9.8 395 12.2 10.1 9.8
E14 0.30 C 0.65 0.65 0.81 90 2.00 6.4 4.1 275 0.94 20 1.9 2.4 8.8 6.5 365 12.0 8.8 6.5
E14.1 1.30 C 0.80 0.80 1.00 10.0 10.0 10.0
E15 0.57 C 0.82 0.82 1.00 60 2.00 3.2 1.1 775 0.33 20 1.2 11.2 14.4 12.3 835 14.6 14.4 12.3
E15.1 0.56 C 0.80 0.80 1.00 10.0 10.0 10.0
E16 1.00 C 0.15 0.15 0.19 10 2.00 4.5 4.3 855 0.30 20 1.1 12.9 17.4 17.2 865 14.8 14.8 14.8
E17 0.59 C 0.65 0.65 0.81 40 2.00 4.2 2.7 450 0.58 20 1.5 4.9 9.2 7.6 490 12.7 9.2 7.6
E17.1 0.40 C 0.55 0.55 0.69 40 2.00 5.1 3.8 450 0.58 20 1.5 4.9 10.1 8.8 490 12.7 10.1 8.8
E18 0.41 C 0.55 0.55 0.69 40 2.00 5.2 3.9 300 0.86 20 1.9 2.7 7.8 6.6 340 11.9 7.8 6.6
E19 2.72 C 0.80 0.80 1.00 10.0 10.0 10.0
E20 0.74 C 0.76 0.76 0.95 30 2.00 2.8 1.2 1000 0.26 20 1.0 16.4 19.1 17.6 1030 15.7 15.7 15.7
E20.1 0.23 C 0.76 0.76 0.96 30 2.00 2.7 1.2 500 0.50 20 1.4 5.8 8.5 7.0 530 12.9 8.5 7.0
E21 1.04 C 0.20 0.20 0.26 50 2.00 9.4 8.9 675 2.00 15 0.9 12.1 21.5 21.0 725 14.0 14.0 14.0
E22 0.99 C 0.76 0.76 0.96 45 2.00 3.3 1.4 100 2.59 20 3.2 0.5 3.9 2.0 145 10.8 5.0 5.0
E23 0.99 C 0.77 0.77 0.96 45 2.00 3.3 1.4 100 1.47 20 2.4 0.7 4.0 2.1 145 10.8 5.0 5.0
E24 0.73 C 0.54 0.54 0.67 80 2.00 7.5 5.7 420 0.35 20 1.2 5.9 13.4 11.6 500 12.8 12.8 11.6
E24.1 0.36 C 0.67 0.67 0.84 80 2.00 5.7 3.5 420 0.50 20 1.2 5.9 11.6 9.4 500 12.8 11.6 9.4
E25 0.74 C 0.78 0.78 0.98 50 2.00 3.3 1.3 675 0.22 20 0.9 12.1 15.4 13.3 725 14.0 14.0 13.3
E25.1 0.19 C 0.62 0.62 0.78 30 2.00 3.9 2.6 420 0.50 20 1.2 5.9 9.8 8.5 450 12.5 9.8 8.5
E26 2.39 C 0.80 0.80 1.00 10.0 10.0 10.0
E26.1 0.72 C 0.80 0.80 1.00 10.0 10.0 10.0
E27 0.33 C 0.69 0.69 0.86 100 2.00 6.1 3.5 75 1.96 20 2.8 0.4 6.5 4.0 175 11.0 6.5 5.0
E28 0.84 C 0.76 0.76 0.95 20 2.00 2.3 1.0 800 0.18 20 0.9 15.6 17.8 16.6 820 14.6 14.6 14.6
E29 1.77 C 0.15 0.15 0.19 10 2.00 4.5 4.3 75 1.96 20 2.8 0.4 4.9 4.7 85 10.5 5.0 5.0
E30 1.04 C 0.77 0.77 0.97 25 2.00 2.4 1.0 1000 0.50 20 0.8 21.7 24.2 22.7 1025 15.7 15.7 15.7
G1 1.15 C 0.79 0.79 0.99 25 2.00 2.3 0.8 1250 0.75 20 0.7 30.4 32.7 31.2 1275 17.1 17.1 17.1
G2 1.15 C 0.79 0.79 0.99 25 2.00 2.3 0.8 1250 0.75 20 0.7 30.4 32.7 31.2 1275 17.1 17.1 17.1
G3 1.18 C 0.81 0.81 1.00 25 2.00 2.2 0.7 1200 0.75 20 0.7 28.6 30.7 29.3 1225 16.8 16.8 16.8
G4 1.16 C 0.81 0.81 1.00 25 2.00 2.2 0.7 1200 0.75 20 0.7 28.6 30.7 29.3 1225 16.8 16.8 16.8
G5 0.34 C 0.77 0.77 0.96 25 2.00 2.5 1.1 450 1.50 20 1.1 6.6 9.0 7.6 475 12.6 9.0 7.6
G6 0.37 C 0.77 0.77 0.96 25 2.00 2.5 1.1 450 1.50 20 1.1 6.6 9.0 7.6 475 12.6 9.0 7.6
G6.1 0.45 C 0.77 0.77 0.96 25 2.00 2.5 1.0 450 1.50 20 1.1 6.6 9.0 7.6 475 12.6 9.0 7.6
G7.1 0.42 C 0.81 0.81 1.00 25 2.00 2.2 0.7 450 1.50 20 1.1 6.6 8.7 7.3 475 12.6 8.7 7.3
G7 0.46 C 0.78 0.78 0.98 25 2.00 2.3 0.9 350 0.60 20 1.3 4.5 6.8 5.4 375 12.1 6.8 5.4
G8 0.48 C 0.78 0.78 0.97 25 2.00 2.4 1.0 350 0.60 20 1.3 4.5 6.9 5.5 375 12.1 6.9 5.5
FUT-G 17.03 C 3.33 3.33 1.00 100 93.00 -9.2 0.4 500 0.05 20 1.1 7.7 -1.5 8.1 600 13.3 5.0 8.1
H1 0.44 C 0.77 0.77 0.97 25 2.00 2.4 1.0 370 0.50 20 1.3 4.9 7.3 5.9 395 12.2 7.3 5.9
H2 0.53 C 0.77 0.77 0.96 25 2.00 2.4 1.0 370 0.50 20 1.3 4.9 7.3 5.9 395 12.2 7.3 5.9
H3 0.92 C 0.80 0.80 1.00 25 2.00 2.2 0.7 380 0.50 20 1.2 5.1 7.3 5.8 405 12.3 7.3 5.8
H4 1.02 C 0.80 0.80 0.99 25 2.00 2.3 0.8 380 0.50 20 1.2 5.1 7.4 5.9 405 12.3 7.4 5.9
FUT-A 56.00 C 0.80 0.80 1.00 10.0 10.0 10.0
FUT-B 15.30 C 0.80 0.80 1.00 10.0 10.0 10.0
FUT-C 22.00 C 0.80 0.80 1.00 10.0 10.0 10.0
NOTES:
Future Developed Area | Multi-Family
Future Developed Area | Multi-Family
Future Developed Area
Future Developed Area
Future Developed Area
Future Developed Area | Multi-Family
Future Developed Area | Multi-Family
Future Developed Area | Multi-Family
Page 10 of 17 7/12/2022
Subdivision:Mulberry Project Name:Mulberry Filing 1
Location:CO, Fort Collins Project No.:
Calculated By:MJP
Checked By:JP
Date:8/3/21
1 2 3 4 5 6 7 8 9 10 13 15 16 17 18 19 20 21 22 23 24
BASIN D.A.Hydrologic C2 C5 C100 L S Ti | 2-Year Ti | 100-Year L S Cv VEL.Tt COMP. Tc | 2-Year COMP. Tc | 100-Year TOTAL Urbanized Tc Tc | 2-Year Tc | 100-Year
ID (AC)Soils Group Cf=1.00 Cf=1.00 Cf=1.25 (FT)(%)(MIN)(MIN)(FT)(%)(FPS)(MIN)(MIN)(MIN)LENGTH(FT)(MIN)(MIN)(MIN)
DATA
STANDARD FORM SF-2
TIME OF CONCENTRATION
SUB-BASIN Tc CHECK
HFH22
FINALINITIAL/OVERLAND
(Ti)
TRAVEL TIME
(URBANIZED BASINS)(Tt)
Ti = (1.87*(1.1 - CCf)*(L)^0.5)/((S)^0.33), S in %Cv
Tt=L/60V 2.5
Velocity V=Cv*S^0.5, S in ft/ft 5
Tc Check = 10+L/180 7
For urbanized basins a minimum Tc of 5.0 minutes is required.10
For non-urbanized basins a minimum Tc of 10.0 minutes is required 15
20Paved Areas and Shallow Paved Swales
Type of Land Surface
Heavy Meadow
Tillage/Field
Short Pasture and Lawns
Nearly Bare Ground
Grassed Waterway
Page 11 of 17 7/12/2022
Project Name:Mulberry Filing 1
Subdivision:Mulberry Project No.:HFH22
Location:CO, Fort Collins Calculated By:MJP
Design Storm:Checked By:JP
Date:
TRAVEL TIME
STREET
DesignPointBasinIDArea(Ac)RunoffCoeff.|C2Tc|2-Year(min)C*A(Ac)I(in/hr)Q(cfs)Tc(min)C*A(Ac)I(in/hr)Q(cfs)Slope(%)StreetFlow(cfs)DesignFlow(cfs)Slope(%)PipeSize(inches)Length(ft)Velocity(fps)Tt(min)REMARKS
D1 D1 1.37 0.59 10.8 0.80 2.15 1.7
D2 D2 3.29 0.59 15.9 1.95 1.82 3.6
D3 D3 1.11 0.69 10.2 0.76 2.19 1.7
D3.1 D3.1 0.71 0.60 13.2 0.42 2.00 0.8
D4 D4 1.04 0.60 10.8 0.63 2.15 1.3
D5 D5 1.13 0.62 12.8 0.69 2.02 1.4
D6 D6 1.32 0.63 13.8 0.83 1.95 1.6
13.8 1.52 1.95 3.0
D7 D7 1.57 0.62 12.8 0.98 2.02 2.0
D8 D8 1.24 0.60 6.4 0.74 2.67 2.0
D8.1 D8.1 0.17 0.79 8.1 0.14 2.45 0.3
D9 D9 1.56 0.63 6.9 0.99 2.60 2.6
D10 D10 0.54 0.72 7.8 0.39 2.49 1.0
D11 D11 1.15 0.65 9.6 0.75 2.27 1.7
D12 D12 1.48 0.64 11.6 0.94 2.10 2.0
D13 D13 0.97 0.20 11.9 0.20 2.08 0.4
D14 D14 0.75 0.70 6.2 0.52 2.69 1.4
D15 D15 0.70 0.59 8.3 0.42 2.43 1.0
D15.1 D15.1 0.93 0.63 10.7 0.59 2.16 1.3
D16 D16 1.06 0.72 6.2 0.77 2.70 2.1
D17 D17 1.07 0.72 6.2 0.77 2.69 2.1
D18 D18 0.37 0.25 13.1 0.09 2.00 0.2
D19 D19 0.62 0.79 13.3 0.49 1.99 1.0
D20 D20 0.60 0.82 9.2 0.49 2.31 1.1
D21 D21 1.60 0.19 15.1 0.30 1.87 0.6
D22 D22 0.24 0.15 5.6 0.04 2.77 0.1
D23 D23 0.68 0.43 9.8 0.29 2.24 0.7
D24 D24 3.02 0.15 5.0 0.45 2.85 1.3
OS1 OS1 0.70 0.44 9.0 0.31 2.34 0.7
OS2 OS2 0.54 0.35 9.0 0.19 2.34 0.4
OS3 OS3 0.85 0.33 12.4 0.28 2.05 0.6
OS4 OS4 0.29 0.46 5.0 0.13 2.85 0.4
OS5 OS5 0.15 0.79 5.0 0.12 2.85 0.3
OS6 OS6 0.43 0.60 8.2 0.26 2.44 0.6
OS7 OS7 0.41 0.57 8.4 0.23 2.42 0.6
DIRECT RUNOFF TOTAL RUNOFF STREET PIPE
STANDARD FORM SF-3
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
2-Year
8/3/21
Page 12 of 17 7/12/2022
Project Name:Mulberry Filing 1
Subdivision:Mulberry Project No.:HFH22
Location:CO, Fort Collins Calculated By:MJP
Design Storm:Checked By:JP
Date:
TRAVEL TIME
STREET
DesignPointBasinIDArea(Ac)RunoffCoeff.|C2Tc|2-Year(min)C*A(Ac)I(in/hr)Q(cfs)Tc(min)C*A(Ac)I(in/hr)Q(cfs)Slope(%)StreetFlow(cfs)DesignFlow(cfs)Slope(%)PipeSize(inches)Length(ft)Velocity(fps)Tt(min)REMARKS
DIRECT RUNOFF TOTAL RUNOFF STREET PIPE
STANDARD FORM SF-3
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
2-Year
8/3/21
E1 E1 1.07 0.72 6.6 0.77 2.65 2.0
E2 E2 0.96 0.76 6.0 0.73 2.72 2.0
E3 E3 0.80 0.68 10.7 0.54 2.16 1.2
E3.1 E3.1 0.80 0.68 10.7 0.54 2.16 1.2
E4 E4 0.40 0.22 10.3 0.09 2.19 0.2
E5 E5 1.07 0.72 5.0 0.77 2.85 2.2
E6 E6 0.63 0.68 7.9 0.43 2.48 1.1
E7 E7 1.03 0.74 5.0 0.76 2.85 2.2
E8 E8 0.35 0.21 10.4 0.07 2.18 0.2
E9 E9 1.07 0.72 5.0 0.77 2.85 2.2
E10 E10 1.03 0.74 5.0 0.76 2.85 2.2
E11 E11 0.40 0.55 8.8 0.22 2.37 0.5
E11.1 E11.1 0.34 0.68 7.9 0.23 2.48 0.6
E12 E12 0.44 0.79 7.2 0.34 2.57 0.9
E12.1 E12.1 0.21 0.94 5.0 0.20 2.85 0.6
E13 E13 0.59 0.15 10.1 0.09 2.21 0.2
E14 E14 0.30 0.65 8.8 0.19 2.37 0.5
E14.1 E14.1 1.30 0.80 10.0 1.04 2.21 2.3
E15 E15 0.57 0.82 14.4 0.47 1.91 0.9
E15.1 E15.1 0.56 0.80 10.0 0.45 2.21 1.0
E16 E16 1.00 0.15 14.8 0.15 1.88 0.3
E17 E17 0.59 0.65 9.2 0.38 2.32 0.9
E17.1 E17.1 0.40 0.55 10.1 0.22 2.21 0.5
E18 E18 0.41 0.55 7.8 0.22 2.49 0.6
E19 E19 2.72 0.80 10.0 2.18 2.21 4.8
E20 E20 0.74 0.76 15.7 0.57 1.83 1.0
E20.1 E20.1 0.23 0.76 8.5 0.18 2.40 0.4
E21 E21 1.04 0.20 14.0 0.21 1.94 0.4
E22 E22 0.99 0.76 5.0 0.76 2.85 2.2
E23 E23 0.99 0.77 5.0 0.76 2.85 2.2
E24 E24 0.73 0.54 12.8 0.39 2.02 0.8
E24.1 E24.1 0.36 0.67 11.6 0.24 2.10 0.5
E25 E25 0.74 0.78 14.0 0.58 1.94 1.1
E25.1 E25.1 0.19 0.62 9.8 0.12 2.24 0.3
E26 E26 2.39 0.80 10.0 1.91 2.21 4.2
E26.1 E26.1 0.72 0.80 10.0 0.57 2.21 1.3
E27 E27 0.33 0.69 6.5 0.23 2.66 0.6
E28 E28 0.84 0.76 14.6 0.64 1.90 1.2
E29 E29 1.77 0.15 5.0 0.27 2.85 0.8
E30 E30 1.04 0.77 15.7 0.80 1.83 1.5
Page 13 of 17 7/12/2022
Project Name:Mulberry Filing 1
Subdivision:Mulberry Project No.:HFH22
Location:CO, Fort Collins Calculated By:MJP
Design Storm:Checked By:JP
Date:
TRAVEL TIME
STREET
DesignPointBasinIDArea(Ac)RunoffCoeff.|C2Tc|2-Year(min)C*A(Ac)I(in/hr)Q(cfs)Tc(min)C*A(Ac)I(in/hr)Q(cfs)Slope(%)StreetFlow(cfs)DesignFlow(cfs)Slope(%)PipeSize(inches)Length(ft)Velocity(fps)Tt(min)REMARKS
DIRECT RUNOFF TOTAL RUNOFF STREET PIPE
STANDARD FORM SF-3
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
2-Year
8/3/21
G1 G1 1.15 0.79 17.1 0.92 1.76 1.6
G3 G3 1.18 0.81 16.8 0.95 1.78 1.7
G4 G4 1.16 0.81 16.8 0.94 1.78 1.7
G5 G5 0.34 0.77 9.0 0.26 2.33 0.6
G6 G6 0.37 0.77 9.0 0.28 2.33 0.7
G6.1 G6.1 0.45 0.77 9.0 0.34 2.33 0.8
G7.1 G7.1 0.42 0.81 8.7 0.34 2.37 0.8
G7 G7 0.46 0.78 6.8 0.36 2.61 0.9
G8 G8 0.48 0.78 6.9 0.37 2.61 1.0
H1 H1 0.44 0.77 7.3 0.34 2.55 0.9
H2 H2 0.53 0.77 7.3 0.41 94.46 38.6
H3 H3 0.92 0.80 7.3 0.73 2.55 1.9
H4 H4 1.02 0.80 7.4 0.81 2.55 2.1
Page 14 of 17 7/12/2022
STANDARD FORM SF-3
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
Project Name:Mulberry Filing 1
Subdivision:Mulberry Project No.:HFH22
Location:CO, Fort Collins Calculated By:MJP
Design Storm:Checked By:JP
Date:
TRAVEL TIME
STREET
DesignPointBasinIDArea(Ac)RunoffCoeff.|C100Tc|100-Year(min)C*A(Ac)I(in/hr)Q(cfs)Tc(min)C*A(Ac)I(in/hr)Q(cfs)Slope(%)StreetFlow(cfs)DesignFlow(cfs)Slope(%)PipeSize(inches)Length(ft)Velocity(fps)Tt(min)REMARKS
D1 D1 1.37 0.73 8.4 1.00 8.45 8.5 0.5 3.7 734 14.1 0.9
D2 D2 3.29 0.74 15.9 2.44 6.35 15.5
D3 D3 1.11 0.86 7.4 0.96 8.86 8.5 0.5 8.5 400 14.1 0.5
8.8 1.96 8.24 16.1
D3.1 D3.1 0.71 0.75 10.7 0.53 7.54 4.0 10.7 2.48 7.54 18.7 Total Flow at D3
D4 D4 1.04 0.75 8.4 0.78 8.43 6.6
D5 D5 1.13 0.77 10.3 0.87 7.66 6.6
D6 D6 1.32 0.78 11.3 1.03 7.41 7.7
11.3 1.90 7.41 14.1
D7 D7 1.57 0.78 10.3 1.22 7.65 9.4
D8 D8 1.24 0.75 5.4 0.93 9.75 9.1
D8.1 D8.1 0.17 0.99 5.0 0.17 9.95 1.7
D9 D9 1.56 0.79 6.0 1.24 9.49 11.8
D10 D10 0.54 0.91 5.0 0.49 9.95 4.9
D11 D11 1.15 0.81 6.9 0.94 9.09 8.5
D12 D12 1.48 0.80 9.4 1.18 7.99 9.4
D13 D13 0.97 0.26 11.9 0.25 7.27 1.8
D14 D14 0.75 0.87 5.0 0.66 9.95 6.5
D15 D15 0.70 0.74 7.1 0.52 9.01 4.7
D15.1 D15.1 0.93 0.79 9.4 0.73 8.00 5.9
D16 D16 1.06 0.91 5.0 0.96 9.95 9.5
D17 D17 1.07 0.90 5.0 0.96 9.95 9.6
D18 D18 0.37 0.31 13.1 0.11 6.99 0.8
D19 D19 0.62 0.99 11.4 0.61 7.38 4.5
11.4 0.94 7.38 7.0 Combined with D23
D20 D20 0.60 1.00 7.5 0.60 8.83 5.3
D21 D21 1.60 0.23 15.1 0.37 6.51 2.4
D22 D22 0.24 0.19 5.5 0.05 9.75 0.4
D23 D23 0.68 0.53 8.7 0.36 8.32 3.0
D24 D24 3.02 0.19 5.0 0.57 9.95 5.6
OS1 OS1 0.70 0.55 7.8 0.38 8.69 3.3
OS2 OS2 0.54 0.44 8.1 0.24 8.58 2.0
OS3 OS3 0.85 0.41 11.8 0.35 7.30 2.6
OS4 OS4 0.29 0.57 5.0 0.17 9.95 1.7
OS5 OS5 0.15 0.99 5.0 0.15 9.95 1.5
OS6 OS6 0.43 0.75 7.2 0.32 8.96 2.9
OS7 OS7 0.41 0.72 7.4 0.29 8.87 2.6
EX-1 EX-1 0.78 1.00 14.9 0.78 6.53 5.1 14.9 2.68 6.53 17.5 Total Flow to Existing Inlet
100-Year
DIRECT RUNOFF TOTAL RUNOFF STREET
6/2/21
PIPE
Page 15 of 17 7/12/2022
STANDARD FORM SF-3
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
Project Name:Mulberry Filing 1
Subdivision:Mulberry Project No.:HFH22
Location:CO, Fort Collins Calculated By:MJP
Design Storm:Checked By:JP
Date:
TRAVEL TIME
STREET
DesignPointBasinIDArea(Ac)RunoffCoeff.|C100Tc|100-Year(min)C*A(Ac)I(in/hr)Q(cfs)Tc(min)C*A(Ac)I(in/hr)Q(cfs)Slope(%)StreetFlow(cfs)DesignFlow(cfs)Slope(%)PipeSize(inches)Length(ft)Velocity(fps)Tt(min)REMARKS
100-Year
DIRECT RUNOFF TOTAL RUNOFF STREET
6/2/21
PIPE
E1 E1 1.07 0.90 5.0 0.96 9.95 9.6
E2 E2 0.96 0.95 5.0 0.91 9.95 9.1
E3 E3 0.80 0.85 9.4 0.68 8.01 5.4
E3.1 E3.1 0.80 0.85 9.4 0.68 8.01 5.4
E4 E4 0.40 0.28 9.8 0.11 7.81 0.9
E5 E5 1.07 0.90 5.0 0.96 9.95 9.5
E6 E6 0.63 0.85 6.8 0.54 9.16 4.9
E7 E7 1.03 0.92 5.0 0.95 9.95 9.5
E8 E8 0.35 0.27 9.9 0.09 7.78 0.7
E9 E9 1.07 0.90 5.0 0.96 9.95 9.6
E10 E10 1.03 0.93 5.0 0.95 9.95 9.5
E11 E11 0.40 0.68 7.9 0.27 8.66 2.3
E11.1 E11.1 0.34 0.85 6.7 0.29 9.18 2.7
E12 E12 0.44 0.99 5.9 0.43 9.56 4.1
E12.1 E12.1 0.21 1.00 5.0 0.21 9.95 2.1
E13 E13 0.59 0.19 9.8 0.11 7.80 0.9
E14 E14 0.30 0.81 6.5 0.24 9.29 2.2
E14.1 E14.1 1.30 1.00 10.0 1.30 7.72 10.0
E15 E15 0.57 1.00 12.3 0.57 7.16 4.1
E15.1 E15.1 0.56 1.00 10.0 0.56 7.72 4.3
E16 E16 1.00 0.19 14.8 0.19 6.57 1.2
E17 E17 0.59 0.81 7.6 0.48 8.78 4.2
E17.1 E17.1 0.40 0.69 8.8 0.28 8.27 2.3
E18 E18 0.41 0.69 6.6 0.28 9.26 2.6
E19 E19 2.72 1.00 10.0 2.72 7.72 21.0
E20 E20 0.74 0.95 15.7 0.71 6.39 4.5
E21 E20.1 0.23 0.96 7.0 0.22 9.08 2.0
E21 E21 1.04 0.26 14.0 0.27 6.75 1.8
E22 E22 0.99 0.96 5.0 0.95 9.95 9.4
E23 E23 0.99 0.96 5.0 0.94 9.95 9.4
E24 E24 0.73 0.67 11.6 0.49 7.33 3.6
E24.1 E24.1 0.36 0.84 9.4 0.30 7.97 2.4
E25 E25 0.74 0.98 13.3 0.73 6.93 5.0
E25.1 E25.1 0.19 0.78 8.5 0.15 8.37 1.2
E26 E26 2.39 1.00 10.0 2.39 7.72 18.5
E26.1 E26.1 0.72 1.00 10.0 0.72 7.72 5.5
E27 E27 0.33 0.86 5.0 0.29 9.95 2.9
E29 E29 1.77 0.19 5.0 0.33 9.95 3.3
E30 E30 1.04 0.97 15.7 1.00 6.39 6.4
Page 16 of 17 7/12/2022
STANDARD FORM SF-3
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
Project Name:Mulberry Filing 1
Subdivision:Mulberry Project No.:HFH22
Location:CO, Fort Collins Calculated By:MJP
Design Storm:Checked By:JP
Date:
TRAVEL TIME
STREET
DesignPointBasinIDArea(Ac)RunoffCoeff.|C100Tc|100-Year(min)C*A(Ac)I(in/hr)Q(cfs)Tc(min)C*A(Ac)I(in/hr)Q(cfs)Slope(%)StreetFlow(cfs)DesignFlow(cfs)Slope(%)PipeSize(inches)Length(ft)Velocity(fps)Tt(min)REMARKS
100-Year
DIRECT RUNOFF TOTAL RUNOFF STREET
6/2/21
PIPE
G1 G1 1.15 0.99 17.1 1.14 6.14 7.0
G2 G2 1.15 0.99 17.1 1.14 6.14 7.0
G3 G3 1.18 1.00 16.8 1.18 6.19 7.3
G4 G4 1.16 1.00 16.8 1.16 6.19 7.2
G5 G5 0.34 0.96 7.6 0.33 8.78 2.9
G6 G6 0.37 0.96 7.6 0.35 8.78 3.1
G6.1 G6.1 0.45 0.96 7.6 0.43 8.79 3.8
G7.1 G7.1 0.42 1.00 7.3 0.42 330.28 137.9
G7 G7 0.46 0.98 5.4 0.45 9.78 4.4
G8 G8 0.48 0.97 5.5 0.47 9.74 4.5
FUT-G FUT-G 17.03 1.00 8.1 17.03 8.57 145.9
H1 H1 0.44 0.97 5.9 0.43 9.56 4.1
H2 H2 0.53 0.96 5.9 0.51 9.55 4.9
H3 H3 0.92 1.00 5.8 0.92 9.58 8.8
H4 H4 1.02 0.99 5.9 1.02 9.56 9.7
Page 17 of 17 7/12/2022
Bloom Filing 1
Final Drainage Report
APPENDIX D
Hydraulic Calculations
Project:Bloom F1
Calculations By:M. Pepin
Date:6/1/2022
Manning's Formula for flow in shallow triangular channels:
Q = 0.56(Z/n)S01/2y8/3
Where:
Q Theoretical Gutter Capacity, cfs
y Depth of Flow at Face of Gutter, ft
n Roughness Coefficient,see below
S0 Longitudinal Channel Slope, ft/ft
Sa Cross-Slope of Gutter Pan, ft/ft
Sb Cross-Slope of Gutter Pan, ft/ft
Sc Cross-Slope of Asphalt, ft/ft
Z Reciprocal of Cross-Slope, ft/ft
n 0.016
Sa 0.00%Za = 1/Sa 0.00 Za/n 0
Sb 8.33%Zb = 1/Sb 12.00 Zb/n 750
Sc 2.00%Zc = 1/Sc 50.00 Zc/n 3125
FL to FL Distance 15' CL to FL (Vert.)Select
y 0.43 water depth at flowline, ft 5.64
y' 0.26 water depth at EOP, ft
S0 =See Below longitudinal slope of street, %
a b b'c 100-year
0.56(Z/n)y8/3 =79.95 0.00 43.33 11.57 48.19 Depth 99.95
Street Name Determination
D1 Aria Way 15 Local 1.7 8.5 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D14 Aria Way 15 Local 0.4 1.8 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D15 Conquest Street 15 Local 1.4 6.5 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D15.1 Aria Way 15 Local 1.0 4.7 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D2 Parkland Street 15 Local 3.6 15.5 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D3 Tourmaline Place 15 Local 1.7 8.5 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D4 Tourmaline Place 15 Local 0.8 4.0 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D6 Parkland Street 15 Local 1.6 6.6 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D7 Whisperwind Lane 15 Local 2.0 7.7 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D8 Parkland Street 15 Local 2.0 9.4 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
D9 Conquest Street 15 Local 0.3 1.7 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E11 Crusader Street 15 Local 1.2 5.4 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E12 Aria Way 15 Local 2.2 9.5 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E12.1 Aria Way 15 Local 1.1 4.9 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E14 Crusader Street 15 Local 0.2 0.7 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E20 Flourish Lane 15 Local 2.3 10.0 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E24 Aria Way 15 Local 0.9 4.2 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E24.1 Crusader Street 15 Local 0.5 2.3 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E25 Flourish Lane 15 Local 0.6 2.6 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E25.1 Crusader Street 15 Local 4.8 21.0 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Problem
E27 Aria Way 15 Local 0.4 9.4 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E3 Aria Way 15 Local 0.6 2.6 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E6 Roselyn 15 Local 0.6 2.9 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
E8 Comet Street 15 Local 2.0 9.6 0.45%5.4 1.00 5.4 Okay 18.0 1.00 18.0 Okay
Notes:
1. Capacity shown is for half-section with flow depth at right-of-way.
Minor Storm
Reduction Factor
(UDFCD Figure 7-4)
Allowable
Capacity
cfs
Calculated Capacity
(FlowMaster)1
cfs
Major Storm
Reduction Factor
(UDFCD Figure 7-4)
Determination
(see below for
notes )
Allowable
Capacity
cfs
Street Capacity Calculations
Vertical Curb & Gutter - 15' CL to FL
Inputs
Results
Minor Storm Event Major Storm Event
Longitudinal
Grade, S0
%
Calculated
Capacity
cfs
Design Point
Width
FL to CL
ft
Street Classification
Developed
Q2
cfs
Developed
Q100
cfs
Sc
Project:Bloom F1
Calculations By:M. Pepin
Date:6/1/2022
Manning's Formula for flow in shallow triangular channels:
Q = 0.56(Z/n)S0
1/2y8/3
Where:
Q Theoretical Gutter Capacity, cfs
y Depth of Flow at Face of Gutter, ft
n Roughness Coefficient,see below
S0 Longitudinal Channel Slope, ft/ft
Sa Cross-Slope of Gutter Pan, ft/ft
Sb Cross-Slope of Gutter Pan, ft/ft
Sc Cross-Slope of Asphalt, ft/ft
Z Reciprocal of Cross-Slope, ft/ft
n 0.016
Sa 0.00%Za = 1/Sa 0.00 Za/n 0
Sb 8.33%Zb = 1/Sb 12.00 Zb/n 750
Sc 2.00%Zc = 1/Sc 50.00 Zc/n 3125
FL to FL Distance 27' CL to FL (Vert.)Select
y 0.5000 water depth at flowline, ft
y' 0.5000 water depth at EOP, ft
S0 =See Below longitudinal slope of street, %
a b b'c 100-year
0.56(Z/n)y8/3 =275.61 0.00 66.17 66.17 275.61 Depth 99.90
Street Name Determination
D19 Sykes Drive 27 0.2 0.8 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
D20 Sykes Drive 27 1.0 4.5 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E12 Aria Way 27 2.2 9.5 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E12.1 Aria Way 27 1.1 4.9 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E24 Aria Way 27 0.5 4.2 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E27 Aria Way 27 0.4 9.4 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E15 International Blvd 27 2.2 9.5 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E17 International Blvd 27 0.9 4.1 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E28 Greenfields Drive 27 2.2 9.4 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
E30 Greenfields Drive 27 0.5 2.4 0.50%19.5 1.00 19.5 Okay 31.7 1.00 31.7 Okay
Notes:
1. Capacity shown is for half-section with flow depth at right-of-way.
Calculated
Capacity
cfs
Minor Storm
Reduction Factor
(UDFCD Figure 7-4)
Allowable
Capacity
cfs
Calculated Capacity
(FlowMaster)1
cfs
Major Storm
Reduction Factor
(UDFCD Figure 7-4)
Allowable
Capacity
cfs
Longitudinal
Grade, S0
%
Street Capacity Calculations
Vertical Curb & Gutter - 27' CL to FL
Inputs
Results
Minor Storm Event Major Storm Event
Design Point Width FL to CL
ft Street Classification
Developed
Q2
cfs
Developed
Q100
cfs
Determination
(see below for
notes )
Sc
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME DP D1 | SD Inlet H4 DP D2 | SD Inlet E3.1 DP D3 | SD Inlet H5.1
Site Type (Urban or Rural)URBAN URBAN URBAN
Inlet Application (Street or Area)STREET STREET STREET
Hydraulic Condition On Grade In Sump In Sump
Inlet Type CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)2.4 3.6 1.7
Major QKnown (cfs)11.3 15.5 8.5
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
Minor Bypass Flow Received, Qb (cfs)0.0 0.0 0.0
Major Bypass Flow Received, Qb (cfs)0.0 0.0 0.0
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)2.4 3.6 1.7
Major Total Design Peak Flow, Q (cfs)11.3 15.5 8.5
Minor Flow Bypassed Downstream, Qb (cfs)0.0 N/A N/A
Major Flow Bypassed Downstream, Qb (cfs)3.7 N/A N/A
INLET MANAGEMENT
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP D4 | SD Inlet H5.1A DP D5&D6 | SD Inlet E6 DP D7 | SD Inlet Z5.1
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
1.3 3.0 2.0
6.6 14.3 9.4
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
1.3 3.0 2.0
6.6 14.3 9.4
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP D8 | SD Inlet E5.1 DP 9 | STM Inlet Z3.1 DP10 | STM Inlet Z6
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
2.0 2.6 1.0
9.1 11.8 4.9
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
2.0 2.6 1.0
9.1 11.8 4.9
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP D11 | SD Inlet E3.1A DP D12 | SD Inlet H9 DP D14 | SD Inlet Z2.2
URBAN URBAN URBAN
STREET STREET STREET
In Sump On Grade In Sump
CDOT Type R Curb Opening CDOT/Denver 13 Combination CDOT Type R Curb Opening
1.7 2.0 1.4
8.5 9.4 6.5
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0
0.0 0.0
1.7 2.0 1.4
8.5 9.4 6.5
N/A 0.0 N/A
N/A 1.5 N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP D15 | SD Inlet Z3-A DP D19 | SD Inlet F1 DP D20 | SD Inlet F2.1
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
1.0 1.0 1.1
4.7 4.5 5.3
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
1.0 1.0 1.1
4.7 4.5 5.3
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP E3 | SD S217 DP E11 | SD Inlet I4.1-A.1 DP E14 | SD Inlet i4.1-A
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
1.2 0.5 0.5
5.3 2.3 2.2
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
1.2 0.5 0.5
5.3 2.3 2.2
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP E15 | SD Inlet J5-A DP E17 | SD Inlet J5.1 DP E20 | SD S-205
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
0.9 0.9 1.5
4.1 4.2 6.5
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
0.9 0.9 1.5
4.1 4.2 6.5
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP E12.1 | SD Inlet J4.1-A DP E28 | SD Inlet D1 DP E30 | SD Inlet D2
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
0.6 1.0 0.8
2.1 5.3 6.4
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
0.6 1.0 0.8
2.1 5.3 6.4
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP G1 SD Inlet L2 DP G2 | SD Inlet L1 DP G3 | SD Inlet K1
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
1.6 1.6 1.7
7.0 7.0 7.3
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
1.6 1.6 1.7
7.0 7.0 7.3
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP G4 | SD Inlet K2.1 DP G5 | SD Inlet C3.1A DP G6 | SD Inlet C3.1
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
1.7 1.1 1.1
7.2 5.0 5.0
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
1.7 1.1 1.1
7.2 5.0 5.0
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP G7 | SD Inlet M8 DP G8 | SD Inlet M7.1 DP H1 | SD Inlet M4
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
0.9 1.0 0.9
4.4 4.5 4.1
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0
0.0 0.0
0.9 1.0 0.9
4.4 4.5 4.1
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP H2 | SD Inlet M4.1 DP H3 | SD Inlet M4.1.1 DP D8.1| SD Inlet Z2.1-A
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
1.0 1.9 0.3
4.9 8.8 1.7
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
1.0 1.9 0.3
4.9 8.8 1.7
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP E11.1|SD Inlet I4.3-1 DP E15.1|Inlet J1 DP E17.1 | SD Inlet S-98
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
0.6 2.0 0.5
2.7 8.9 2.3
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
0.6 2.0 0.5
2.7 8.9 2.3
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP E20.1 | SD Inlet F3-B DP E24.1 | SD 210 DP E24 | Inlet I4-A.2
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
0.4 0.8 0.8
2.0 2.4 3.6
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
0.4 0.8 0.8
2.0 2.4 3.6
N/A N/A N/A
N/A N/A N/A
MHFD-Inlet, Version 5.01 (April 2021)
Worksheet Protected
INLET NAME
Site Type (Urban or Rural)
Inlet Application (Street or Area)
Hydraulic Condition
Inlet Type
USER-DEFINED INPUT
User-Defined Design Flows
Minor QKnown (cfs)
Major QKnown (cfs)
Bypass (Carry-Over) Flow from Upstream
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Watershed Characteristics
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Watershed Profile
Overland Slope (ft/ft)
Overland Length (ft)
Channel Slope (ft/ft)
Channel Length (ft)
Minor Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Major Storm Rainfall Input
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
CALCULATED OUTPUT
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
INLET MANAGEMENT
DP E25 | Inlet S202 DP E25.1 | Inlet S205User-Defined
URBAN URBAN
STREET STREET
In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening
0.5 0.3
2.4 1.2
No Bypass Flow Received No Bypass Flow Received
0.0 0.0
0.0 0.0
0.5 0.3
2.4 1.2
N/A N/A
N/A N/A
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.006 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Allow Flow Depth at Street Crown (check box for yes, leave blank for no)
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =6.2 37.4 cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D1 | SD Inlet H4
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D1 | SD Inlet H4 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a')aLOCAL =3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening)No =2 2
Length of a Single Unit Inlet (Grate or Curb Opening)Lo =5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width)Wo =N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR
Total Inlet Interception Capacity Q =2.4 7.6 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 3.7 cfs
Capture Percentage = Qa/Qo =C% =100 67 %
INLET ON A CONTINUOUS GRADE
MHFD-Inlet, Version 5.01 (April 2021)
CDOT Type R Curb OpeningCDOT Type R Curb Opening
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D1 | SD Inlet H4 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D2 | SD Inlet E3.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D2 | SD Inlet E3.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =3 3
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.73 0.94
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =8.6 34.0 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =3.6 15.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D2 | SD Inlet E3.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.013
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D3 | SD Inlet H5.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D3 | SD Inlet H5.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.7 8.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D3 | SD Inlet H5.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =21.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D4 | SD Inlet H5.1A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D4 | SD Inlet H5.1A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.3 6.6 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D4 | SD Inlet H5.1A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =21.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D5&D6 | SD Inlet E6
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D5&D6 | SD Inlet E6 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =3.0 14.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D5&D6 | SD Inlet E6 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D7 | SD Inlet Z5.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D7 | SD Inlet Z5.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =2.0 9.4 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D7 | SD Inlet Z5.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D8 | SD Inlet E5.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D8 | SD Inlet E5.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =2.0 9.1 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D8 | SD Inlet E5.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP 9 | STM Inlet Z3.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP 9 | STM Inlet Z3.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =2.6 11.8 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP 9 | STM Inlet Z3.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP10 | STM Inlet Z6
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP10 | STM Inlet Z6 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.0 4.9 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP10 | STM Inlet Z6 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.3 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D11 | SD Inlet E3.1A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D11 | SD Inlet E3.1A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.7 8.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D11 | SD Inlet E3.1A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.005 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Allow Flow Depth at Street Crown (check box for yes, leave blank for no)
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =5.7 34.1 cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D12 | SD Inlet H9
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D12 | SD Inlet H9 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a')aLOCAL =2.0 2.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening)No =3 3
Length of a Single Unit Inlet (Grate or Curb Opening)Lo =3.00 3.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width)Wo =1.73 1.73 ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5)Cf-G =0.50 0.50
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1)Cf-C =0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity'MINOR MAJOR
Total Inlet Interception Capacity Q =2.1 7.9 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet)Qb =0.0 1.5 cfs
Capture Percentage = Qa/Qo =C% =100 84 %
INLET ON A CONTINUOUS GRADE
MHFD-Inlet, Version 5.01 (April 2021)
CDOT/Denver 13 CombinationCDOT/Denver 13 Combination
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D12 | SD Inlet H9 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =18.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =13.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =13.0 13.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 10.4 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D14 | SD Inlet Z2.2
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D14 | SD Inlet Z2.2 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =4.6 10.4 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.22 0.70 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.59 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =2.9 11.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.4 6.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D14 | SD Inlet Z2.2 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D15 | SD Inlet Z3-A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D15 | SD Inlet Z3-A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.0 4.7 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D15 | SD Inlet Z3-A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D19 | SD Inlet F1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D19 | SD Inlet F1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.0 4.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D19 | SD Inlet F1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D20 | SD Inlet F2.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D20 | SD Inlet F2.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.1 5.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D20 | SD Inlet F2.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E3 | SD S217
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E3 | SD S217 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.2 5.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E3 | SD S217 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E11 | SD Inlet I4.1-A.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E11 | SD Inlet I4.1-A.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.5 2.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E11 | SD Inlet I4.1-A.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E14 | SD Inlet i4.1-A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E14 | SD Inlet i4.1-A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.5 2.2 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E14 | SD Inlet i4.1-A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E15 | SD Inlet J5-A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E15 | SD Inlet J5-A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.9 4.1 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E15 | SD Inlet J5-A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E17 | SD Inlet J5.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E17 | SD Inlet J5.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.9 4.2 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E17 | SD Inlet J5.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E20 | SD S-205
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E20 | SD S-205 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.5 6.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E20 | SD S-205 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E12.1 | SD Inlet J4.1-A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E12.1 | SD Inlet J4.1-A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.6 2.1 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E12.1 | SD Inlet J4.1-A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E28 | SD Inlet D1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E28 | SD Inlet D1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.0 5.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E28 | SD Inlet D1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =20.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 10.8 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E30 | SD Inlet D2
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E30 | SD Inlet D2 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 8.0 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.50 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 9.3 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.8 6.4 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E30 | SD Inlet D2 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G1 SD Inlet L2
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G1 SD Inlet L2 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.6 7.0 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G1 SD Inlet L2 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G2 | SD Inlet L1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G2 | SD Inlet L1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.6 7.0 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G2 | SD Inlet L1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.016
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G3 | SD Inlet K1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G3 | SD Inlet K1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.7 7.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G3 | SD Inlet K1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G4 | SD Inlet K2.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G4 | SD Inlet K2.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.7 7.2 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G4 | SD Inlet K2.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.016
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 6.0 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G5 | SD Inlet C3.1A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G5 | SD Inlet C3.1A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.1 5.0 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G5 | SD Inlet C3.1A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.016
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 6.0 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G6 | SD Inlet C3.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G6 | SD Inlet C3.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.1 5.0 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G6 | SD Inlet C3.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G7 | SD Inlet M8
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G7 | SD Inlet M8 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.9 4.4 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G7 | SD Inlet M8 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP G8 | SD Inlet M7.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G8 | SD Inlet M7.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.0 4.5 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP G8 | SD Inlet M7.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP H1 | SD Inlet M4
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP H1 | SD Inlet M4 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.9 4.1 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP H1 | SD Inlet M4 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP H2 | SD Inlet M4.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP H2 | SD Inlet M4.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.0 4.9 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP H2 | SD Inlet M4.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.016
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =27.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =27.0 27.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 6.0 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP H3 | SD Inlet M4.1.1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP H3 | SD Inlet M4.1.1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.77 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =5.4 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =1.9 8.8 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP H3 | SD Inlet M4.1.1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP D8.1| SD Inlet Z2.1-A
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D8.1| SD Inlet Z2.1-A 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.3 1.7 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP D8.1| SD Inlet Z2.1-A 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E11.1|SD Inlet I4.3-1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E11.1|SD Inlet I4.3-1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.6 2.7 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E11.1|SD Inlet I4.3-1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =16.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =26.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =26.0 26.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.8 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E15.1|Inlet J1
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E15.1|Inlet J1 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.8 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.65 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.57 0.92
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.93 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =10.5 23.1 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =2.0 8.9 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E15.1|Inlet J1 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =16.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =26.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =26.0 26.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.8 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E17.1 | SD Inlet S-98
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E17.1 | SD Inlet S-98 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.8 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.65 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.57 0.92
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.93 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =10.5 23.1 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.5 2.3 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E17.1 | SD Inlet S-98 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =16.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.016
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =26.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =26.0 26.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.8 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E20.1 | SD Inlet F3-B
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E20.1 | SD Inlet F3-B 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =6.0 9.8 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.33 0.65 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.57 0.92
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.93 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =10.5 23.1 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.4 2.0 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E20.1 | SD Inlet F3-B 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E24.1 | SD 210
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E24.1 | SD 210 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.8 2.4 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E24.1 | SD 210 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E24 | Inlet I4-A.2
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E24 | Inlet I4-A.2 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.8 3.6 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E24 | Inlet I4-A.2 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E25 | Inlet S202
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E25 | Inlet S202 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =2 2
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.48 0.87
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =0.88 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =6.8 22.4 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.5 2.4 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E25 | Inlet S202 6/1/2022, 8:37 AM
Project:
Inlet ID:
Gutter Geometry:
Maximum Allowable Width for Spread Behind Curb TBACK =13.5 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb)SBACK =0.020 ft/ft
Warning 01 Manning's Roughness Behind Curb (typically between 0.012 and 0.020)nBACK =0.025
Height of Curb at Gutter Flow Line HCURB =6.00 inches
Distance from Curb Face to Street Crown TCROWN =15.0 ft
Gutter Width W =2.00 ft
Street Transverse Slope SX =0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft)SW =0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO =0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020)nSTREET =0.016
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX =15.0 15.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX =6.0 9.2 inches
Check boxes are not applicable in SUMP conditions
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow =SUMP SUMP cfs
Warning 01: Manning's n-value does not meet the USDCM recommended design range.
MHFD-Inlet, Version 5.01 (April 2021)
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
DP E25.1 | Inlet S205
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E25.1 | Inlet S205 6/1/2022, 8:37 AM
Design Information (Input)MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above)alocal =3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening)No =1 1
Water Depth at Flowline (outside of local depression)Ponding Depth =5.1 9.2 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) =N/A N/A feet
Width of a Unit Grate Wo =N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90)Aratio =N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70)Cf (G) =N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60)Cw (G) =N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80)Co (G) =N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) =5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert =6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat =6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5)Theta =63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet)Wp =2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10)Cf (C) =0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7)Cw (C) =3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70)Co (C) =0.67 0.67
Low Head Performance Reduction (Calculated)MINOR MAJOR
Depth for Grate Midwidth dGrate =N/A N/A ft
Depth for Curb Opening Weir Equation dCurb =0.26 0.60 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination =0.66 1.00
Curb Opening Performance Reduction Factor for Long Inlets RFCurb =1.00 1.00
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate =N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition)Qa =3.7 10.8 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK)Q PEAK REQUIRED =0.3 1.2 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
MHFD-Inlet, Version 5.01 (April 2021)
H-VertH-Curb
W
Lo (C)
Lo (G)
Wo
WP
CDOT Type R Curb Opening
Override Depths
HFH022_MHFD-Inlet_v5.01_F1.xlsm, DP E25.1 | Inlet S205 6/1/2022, 8:37 AM
Scenario: 2 Year
GU-1P-112(StormE)P-111(StormE)P-26(StormE)C
O-7
CO-10CO-1C
O-6
P -4 5 (S to rm H )P-1
2
2(Storm
H)
P-7
9
(Storm
H)P-44(Storm H )P-43(Storm H )P-42(StormH)P-41(Storm H)P-4
0(Stor
m
H)P-
3
9
(St
o
r
mH)P-35(StormG)P-36(StormG)P-37
(Stor
m
G)P-94(Storm B)P-93
(Stor
m
B)P-29(StormF)P-118(StormF)P-28(StormF)P-81(StormF)P-116(StormF)P-120(StormF)P-33(StormF)C
O-13
P-114(StormE)P-115(StormE)P-20(Storm E)P-110(StormE)P-109(StormE)Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-16667/12/2022
Bentley StormCAD V8i (SELECTseries 4)
[08.11.04.54]Bentley Systems, Inc. Haestad Methods Solution CenterHFH022_Storm D_Eastern Pipes.stsw
Scenario: 2 Year
P-90(St
ormB)P-103(StormB)P-91(Storm
B)P-104(Storm B)P-9
2
(Storm
B)
P-1
60
(Storm
B)
P-16
1(Stor
m
B)
P-1
6
2(Stor
m
B)P-94(Storm B)P-9
3(Storm
B)P-1(StormA)P-
3
(St
o
r
mA)P-2(StormA)Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-16667/12/2022
Bentley StormCAD V8i (SELECTseries 4)
[08.11.04.54]Bentley Systems, Inc. Haestad Methods Solution CenterHFH022_Storm D_Eastern Pipes.stsw
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
P-2 (Storm A)SDMH A2 (Storm A)SDMH A1 (Storm A)4,941.97 4,941.49 395.4 0.001 24.0 0.013 9.52 3.03 7.87 4,943.94 4,943.32 4,944.09 4,943.47 0.63
P-1 (Storm A)SDMH A1 (Storm A)SD FES A (Storm A)4,941.49 4,941.01 395.4 0.001 24.0 0.013 9.52 3.03 7.87 4,943.22 4,942.11 4,943.39 4,942.56 1.11
P-3 (Storm A)SD OUTLET STRUCTURE A3 (Storm A)SDMH A2 (Storm A)4,942.01 4,941.97 35.9 0.001 24.0 0.013 9.52 3.03 7.87 4,944.09 4,944.03 4,944.24 4,944.17 0.06
P-93 (Storm B)SDMH B7 (Storm B)SDMH B6 (Storm B)4,941.90 4,941.61 296.7 0.001 18.0 0.013 0.16 0.96 3.28 4,942.59 4,942.59 4,942.59 4,942.59 0.00
P-162 (Storm B)SDMH B6 (Storm B)SDMH B5 (Storm B)4,941.61 4,941.22 400.0 0.001 18.0 0.013 0.16 0.96 3.28 4,942.59 4,942.59 4,942.59 4,942.59 0.00
P-161 (Storm B)SDMH B5 (Storm B)SDMH B4 (Storm B)4,941.22 4,940.84 400.0 0.001 18.0 0.013 0.16 0.95 3.24 4,942.59 4,942.59 4,942.59 4,942.59 0.00
P-160 (Storm B)SDMH B4 (Storm B)SDMH B3 (Storm B)4,940.84 4,940.45 400.0 0.001 18.0 0.013 0.16 0.09 3.28 4,942.59 4,942.59 4,942.59 4,942.59 0.00
P-94 (Storm B)SD OUTLET STRUCTURE B8 (Storm B)SDMH B7 (Storm B)4,942.00 4,941.90 103.0 0.001 18.0 0.013 0.16 0.96 3.27 4,942.59 4,942.59 4,942.60 4,942.59 0.00
P-92 (Storm B)SDMH B3 (Storm B)SDMH B2 (Storm B)4,940.45 4,940.30 149.0 0.001 24.0 0.013 6.48 2.06 7.18 4,942.55 4,942.42 4,942.61 4,942.49 0.12
P-91 (Storm B)SDMH B2 (Storm B)SDMH B1 (Storm B)4,940.30 4,940.17 136.5 0.001 30.0 0.013 14.08 2.87 12.66 4,942.33 4,942.15 4,942.50 4,942.33 0.17
P-90 (Storm B)SDMH B1 (Storm B)SD FES B (Storm B)4,940.17 4,940.01 176.5 0.001 30.0 0.013 14.08 2.87 12.35 4,941.95 4,941.27 4,942.17 4,941.77 0.68
P-103 (Storm B)SD AREA INLET B2.1 (Storm B)SDMH B2 (Storm B)4,941.48 4,940.88 150.6 0.004 24.0 0.013 7.60 4.62 14.31 4,942.60 4,942.45 4,942.88 4,942.58 0.15
P-104 (Storm B)SD OUTLET STRUCTURE B3.1 (Storm B)SDMH B3 (Storm B)4,941.01 4,940.56 80.1 0.006 24.0 0.013 6.32 5.02 17.02 4,942.65 4,942.61 4,942.73 4,942.68 0.04
P-25 (Storm E)SDMH E7 (Storm E)SDMH E6 (Storm E)4,945.48 4,943.81 423.0 0.004 -0.013 3.57 3.44 25.57 4,946.00 4,945.13 4,946.19 4,945.15 0.87
P-26 (Storm E)SDMH E8 (Storm E)SDMH E7 (Storm E)4,945.91 4,945.48 107.0 0.004 30.0 0.013 3.63 3.73 26.00 4,946.68 4,946.67 4,946.80 4,946.71 0.01
CO-4 SDMH E5 (Storm E)MH-4 4,943.57 4,942.57 225.4 0.004 -0.013 8.93 4.59 60.53 4,944.36 4,943.46 4,944.64 4,943.66 0.90
P-27 (Storm E)SD Inlet Z6 SDMH E8 (Storm E)4,946.02 4,945.91 26.0 0.004 18.0 0.013 1.04 2.79 6.83 4,946.78 4,946.78 4,946.80 4,946.79 0.00
P-24 (Storm E)SDMH E6 (Storm E)SDMH E5 (Storm E)4,943.81 4,943.47 78.0 0.004 -0.013 7.70 4.40 43.35 4,944.66 4,944.69 4,944.84 4,944.76 -0.03
P-22 (Storm E)SDMH E4 (Storm E)SDMH E3 (Storm E)4,944.50 4,943.89 186.5 0.003 -0.013 4.77 3.44 37.55 4,945.13 4,945.09 4,945.29 4,945.11 0.04
P-21 (Storm E)SDMH E3 (Storm E)SDMH E2 (Storm E)4,943.89 4,943.18 141.6 0.005 -0.013 9.03 4.84 47.26 4,944.69 4,944.54 4,944.98 4,944.61 0.15
P-110 (Storm E)SDMH E3 (Storm E)SD INLET E3.1A (Storm E)4,943.92 4,943.89 6.4 0.005 18.0 0.013 1.91 1.08 7.18 4,945.09 4,945.08 4,945.11 4,945.11 0.00
P-20 (Storm E)SDMH E2 (Storm E)SDMH E1 (Storm E)4,943.18 4,942.92 66.0 0.004 42.0 0.013 8.90 4.64 63.15 4,944.46 4,944.47 4,944.58 4,944.54 0.00
CO-6 SDMH E1 (Storm E)MH-5 4,942.92 4,942.32 148.9 0.004 42.0 0.013 8.84 4.66 63.86 4,943.82 4,943.59 4,944.14 4,943.71 0.23
P-112 (Storm E)SD Inlet Z3.1 SDMH E6 (Storm E)4,943.92 4,943.81 29.4 0.004 24.0 0.013 2.70 3.41 13.83 4,945.14 4,945.13 4,945.16 4,945.16 0.00
P-111 (Storm E)SD Inlet Z3-A SDMH E6 (Storm E)4,943.81 4,943.84 8.5 -0.004 18.0 0.013 2.29 1.29 6.24 4,945.14 4,945.14 4,945.17 4,945.17 0.00
P-114 (Storm E)SD INLET E4.2 (Storm E)SDMH E4.1 (Storm E)4,944.92 4,944.81 26.4 0.004 24.0 0.013 3.26 3.74 14.60 4,945.65 4,945.64 4,945.80 4,945.75 0.01
P-113 (Storm E)SDMH E4.1 (Storm E)SDMH E4 (Storm E)4,944.81 4,944.48 76.0 0.004 -0.013 4.82 3.81 43.01 4,945.39 4,945.31 4,945.60 4,945.39 0.08
P-115 (Storm E)SDMH E4.1 (Storm E)SD INLET E4.1-1 (Storm E)4,944.84 4,944.81 6.4 0.005 18.0 0.013 1.64 0.93 7.18 4,945.63 4,945.61 4,945.67 4,945.66 0.01
P-109 (Storm E)SD INLET E3.1 (Storm E)SDMH E3 (Storm E)4,944.00 4,943.89 26.4 0.004 24.0 0.013 3.54 3.83 14.60 4,945.10 4,945.10 4,945.16 4,945.15 0.00
P-34 (Storm F)SD AREA INLET F8 (Storm F)SD AREA INLET F7 (Storm F)4,946.75 4,946.55 40.1 0.005 18.0 0.013 2.16 3.64 7.43 4,947.68 4,947.67 4,947.73 4,947.70 0.01
P-32 (1) (Storm F)SDMH F6 (Storm F)SDMH F5 (Storm F)4,945.65 4,945.58 17.0 0.004 18.0 0.013 2.08 3.36 6.74 4,946.71 4,946.70 4,946.75 4,946.74 0.00
P-32 (Storm F)SDMH F5 (Storm F)SDMH F4 (Storm F)4,945.58 4,944.89 174.0 0.004 24.0 0.013 4.11 3.93 14.28 4,946.32 4,946.20 4,946.56 4,946.25 0.12
P-121 (Storm F)SD AREA INLET F5.2 (Storm F)SD AREA INLET F5.1 (Storm F)4,947.03 4,946.81 43.0 0.005 18.0 0.013 2.16 3.64 7.43 4,947.82 4,947.81 4,947.90 4,947.86 0.01
P-120 (Storm F)SD AREA INLET F5.1 (Storm F)SDMH F5 (Storm F)4,946.61 4,945.78 165.6 0.005 18.0 0.013 2.14 3.63 7.43 4,947.16 4,946.71 4,947.37 4,946.77 0.45
P-33 (Storm F)SD AREA INLET F7 (Storm F)SDMH F6 (Storm F)4,946.55 4,946.06 120.8 0.004 18.0 0.013 2.14 3.35 6.64 4,947.13 4,946.78 4,947.30 4,946.88 0.35
P-31 (Storm F)SDMH F4 (Storm F)SDMH F3 (Storm F)4,944.89 4,944.07 203.0 0.004 36.0 0.013 7.82 4.58 42.39 4,945.77 4,945.22 4,946.09 4,945.37 0.55
P-116 (Storm F)SD AREA INLET F4.1 (Storm F)SDMH F4 (Storm F)4,945.54 4,944.71 165.6 0.005 24.0 0.013 2.02 3.49 16.00 4,946.18 4,946.18 4,946.26 4,946.19 0.00
P-117 (Storm F)SD AREA INLET F4.2 (Storm F)SD AREA INLET F4.1 (Storm F)4,945.96 4,945.74 43.0 0.005 18.0 0.013 2.05 3.59 7.43 4,946.50 4,946.34 4,946.69 4,946.49 0.16
P-118 (Storm F)SD AREA INLET F4-A.1 (Storm F)SDMH F4 (Storm F)4,945.32 4,944.71 120.9 0.005 24.0 0.013 2.11 3.53 16.00 4,946.18 4,946.18 4,946.22 4,946.19 0.00
P-119 (Storm F)SD AREA INLET F4-A.2 (Storm F)SD AREA INLET F4-A.1 (Storm F)4,945.78 4,945.52 51.6 0.005 18.0 0.013 2.14 3.63 7.43 4,946.33 4,946.25 4,946.53 4,946.35 0.07
CO-8 SDMH F3 (Storm F)MH-6 4,944.07 4,942.60 415.1 0.004 42.0 0.013 8.28 4.37 59.87 4,944.95 4,943.75 4,945.25 4,943.89 1.20
P-81 (Storm F)SD INLET F2.1 (Storm F)SDMH F2 (Storm F)4,942.64 4,942.41 45.6 0.005 24.0 0.013 1.22 3.01 16.06 4,943.72 4,943.72 4,943.73 4,943.72 0.00
P-28 (Storm F)SD INLET F1 (Storm F)SD FES F (Storm F)4,942.38 4,942.00 81.0 0.005 42.0 0.013 10.27 5.14 68.91 4,943.35 4,942.91 4,943.70 4,943.32 0.44
P-29 (Storm F)SDMH F2 (Storm F)SD INLET F1 (Storm F)4,942.41 4,942.38 11.3 0.003 42.0 0.013 8.73 4.01 51.84 4,943.64 4,943.64 4,943.77 4,943.76 0.00
P-37 (Storm G)SDMH G3 (Storm G)SDMH G2 (Storm G)4,946.37 4,943.40 302.4 0.010 24.0 0.013 6.00 6.05 22.42 4,947.24 4,945.00 4,947.57 4,945.08 2.24
P-36 (Storm G)SDMH G2 (Storm G)SD AREA INLET G1 (Storm G)4,943.40 4,939.44 120.8 0.033 -0.013 6.00 8.71 39.36 4,944.13 4,942.06 4,944.42 4,942.12 2.07
P-38 (Storm G)SD AREA INLET G4 (Storm G)SDMH G3 (Storm G)4,947.00 4,946.37 64.3 0.010 24.0 0.013 6.00 6.04 22.39 4,947.87 4,947.91 4,948.20 4,948.00 -0.05
P-35 (Storm G)SD AREA INLET G1 (Storm G)SD FES G (Storm G)4,939.44 4,939.00 22.1 0.020 -0.013 6.00 1.79 30.67 4,942.03 4,942.01 4,942.08 4,942.07 0.02
P-39 (Storm H)SDMH H1 (Storm H)SD FES H (Storm H)4,943.80 4,943.00 160.4 0.005 30.0 0.013 6.39 4.74 28.97 4,944.64 4,943.80 4,944.94 4,944.15 0.84
P-40 (Storm H)SDMH H2 (Storm H)SDMH H1 (Storm H)4,944.56 4,943.80 151.8 0.005 30.0 0.013 6.53 4.77 29.02 4,945.41 4,944.96 4,945.72 4,945.09 0.45
P-41 (Storm H)SDMH H3 (Storm H)SDMH H2 (Storm H)4,945.11 4,944.56 137.6 0.004 30.0 0.013 6.67 4.43 25.93 4,946.34 4,946.31 4,946.46 4,946.37 0.02
P-43 (Storm H)SDMH H5 (Storm H)SDMH H4 (Storm H)4,945.58 4,945.23 88.7 0.004 30.0 0.013 6.79 4.43 25.76 4,946.52 4,946.49 4,946.77 4,946.61 0.03
P-122 (Storm H)SDMH H5 (Storm H)SD INLET H5.1A (Storm H)4,945.62 4,945.58 6.5 0.006 18.0 0.013 1.49 0.84 8.24 4,946.73 4,946.73 4,946.75 4,946.75 0.00
P-42 (Storm H)SDMH H4 (Storm H)SDMH H3 (Storm H)4,945.23 4,945.11 29.5 0.004 30.0 0.013 6.70 4.46 26.15 4,946.41 4,946.41 4,946.54 4,946.51 0.00
P-46 (Storm H)SDMH H8 (Storm H)SDMH H7 (Storm H)4,946.17 4,945.96 52.8 0.004 18.0 0.013 1.77 3.17 6.63 4,946.82 4,946.80 4,946.91 4,946.85 0.02
P-45 (Storm H)SDMH H7 (Storm H)SDMH H6 (Storm H)4,945.96 4,945.71 61.8 0.004 18.0 0.013 1.74 3.18 6.68 4,946.77 4,946.75 4,946.82 4,946.78 0.01
P-44 (Storm H)SDMH H6 (Storm H)SDMH H5 (Storm H)4,945.71 4,945.58 31.6 0.004 18.0 0.013 1.72 3.19 6.74 4,946.74 4,946.73 4,946.77 4,946.75 0.01
P-79 (Storm H)SD INLET H5.1 (Storm H)SDMH H5 (Storm H)4,945.72 4,945.58 26.4 0.005 24.0 0.013 3.82 4.27 16.47 4,946.75 4,946.75 4,946.83 4,946.81 0.00
P-67 (Storm E)SD Inlet Z5.1 SDMH E8 (Storm E)4,945.94 4,945.91 6.6 0.005 24.0 0.013 2.78 3.68 15.20 4,946.80 4,946.80 4,946.87 4,946.87 0.00
P-47 (Storm H)SD Inlet H9 SDMH H8 (Storm H)4,946.93 4,946.17 190.2 0.004 18.0 0.013 1.86 3.22 6.64 4,947.47 4,946.88 4,947.63 4,946.96 0.60
CO-1 SDMH Z2.1 SDMH E5 (Storm E)4,943.80 4,943.47 -0.006 18.0 0.013 1.81 3.61 7.84 4,944.67 4,944.67 4,944.72 4,944.69 0.01
CO-3 SDMH Z2.1 SD Inlet Z2.1-A 4,943.80 4,943.83 --0.001 18.0 0.013 0.38 1.26 3.37 4,944.68 4,944.68 4,944.69 4,944.69 0.00
CO-2 SD Inlet Z2.2 SDMH Z2.1 4,943.91 4,943.80 28.6 0.004 18.0 0.013 1.47 2.98 6.52 4,944.70 4,944.69 4,944.74 4,944.72 0.01
CO-5 O-1 MH-4 4,942.00 4,942.57 143.0 -0.004 42.0 0.013 8.69 4.62 63.52 4,943.46 4,942.87 4,943.78 4,943.21 0.59
Page 1 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/zhwsiosb.xml
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm D_Eastern Pipes.stsw
CO-7 MH-5 SD FES E (Storm E)4,942.32 4,942.00 80.8 0.004 42.0 0.013 8.70 4.61 63.31 4,943.21 4,942.88 4,943.53 4,943.21 0.33
CO-9 MH-6 SDMH F2 (Storm F)4,942.60 4,942.41 48.0 0.004 42.0 0.013 7.89 4.49 63.30 4,943.75 4,943.75 4,943.88 4,943.84 0.00
CO-10 MH-7 SDMH F3 (Storm F)4,944.94 4,943.87 212.8 0.005 24.0 0.013 2.65 3.78 16.04 4,945.51 4,945.16 4,945.71 4,945.18 0.35
CO-11 SD Inlet F3-B MH-7 4,945.32 4,945.13 37.5 0.005 18.0 0.013 0.54 2.46 7.48 4,946.04 4,946.04 4,946.05 4,946.04 0.00
CO-12 MH-9 MH-7 4,945.22 4,945.13 -0.006 18.0 0.013 2.49 3.97 7.91 4,946.07 4,946.07 4,946.16 4,946.14 0.00
CO-13 MH-10 O-2 4,951.61 4,951.41 -0.005 12.0 0.013 0.40 1.71 7.65 4,951.77 4,951.56 4,951.81 4,951.61 0.21
Page 2 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/zhwsiosb.xml
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
P-95 (Storm C)SDMH C4 (Storm C)SDMH C3 (Storm C)4,937.66 4,933.56 413.3 0.010 18.0 0.013 3.70 5.41 10.47 4,938.40 4,934.59 4,938.68 4,934.72 3.80
P-10 (Storm C)SD OUTLET STRUCTURE C5 (Storm C)SDMH C4 (Storm C)4,939.01 4,937.66 136.0 0.010 18.0 0.013 3.70 5.41 10.46 4,939.74 4,939.20 4,940.03 4,939.27 0.54
P-71 (Storm C)SD INLET C3.1 (Storm C)SDMH C3 (Storm C)4,933.79 4,933.56 47.0 0.005 36.0 0.013 0.70 2.42 47.16 4,934.53 4,934.53 4,934.54 4,934.54 0.00
P-107 (Storm C)SDMH C3 (Storm C)SD INLET C3.1A (Storm C)4,933.59 4,933.56 6.0 0.005 36.0 0.013 0.65 0.09 47.16 4,934.53 4,934.53 4,934.54 4,934.54 0.00
P-70 (Storm C)SDMH C3 (Storm C)SDMH C2 (Storm C)4,933.56 4,931.78 356.0 0.005 -0.013 4.99 4.05 46.61 4,934.15 4,932.93 4,934.36 4,932.96 1.22
P-105 (Storm C)SDMH C2 (Storm C)SD INLET C2.1A (Storm C)4,933.34 4,933.28 6.0 0.010 18.0 0.013 0.86 0.48 10.50 4,933.77 4,933.68 4,933.82 4,933.80 0.09
P-69 (Storm C)SDMH C2 (Storm C)SDMH C1 (Storm C)4,931.78 4,929.84 388.1 0.005 36.0 0.013 6.44 4.67 47.16 4,932.58 4,931.38 4,932.86 4,931.43 1.19
P-68 (Storm C)SDMH C1 (Storm C)STORM FES C (Storm C)4,929.84 4,929.39 63.5 0.007 36.0 0.013 6.30 5.26 56.17 4,930.63 4,930.07 4,930.91 4,930.50 0.56
P-99 (Storm K)SDMH K4 (Storm K)SDMH K3 (Storm K)4,932.89 4,932.17 180.9 0.004 54.0 0.013 15.00 5.28 124.36 4,933.99 4,933.58 4,934.38 4,933.77 0.41
P-187 (1) (Storm K)SDMH K5 (Storm K)SDMH K4 (Storm K)4,934.40 4,932.89 377.1 0.004 42.0 0.013 5.00 3.94 63.63 4,935.07 4,934.65 4,935.30 4,934.67 0.42
P-98 (Storm K)SDMH K3 (Storm K)SDMH K2 (Storm K)4,932.17 4,931.41 186.6 0.004 54.0 0.013 15.00 5.32 125.62 4,933.26 4,933.01 4,933.65 4,933.14 0.26
P-97 (Storm K)SDMH K2 (Storm K)SD INLET K1 (Storm K)4,931.41 4,931.25 38.4 0.004 54.0 0.013 16.61 5.42 123.79 4,932.81 4,932.83 4,933.05 4,933.00 -0.01
P-147 (Storm K)SD INLET K2.1 (Storm K)SDMH K2 (Storm K)4,932.99 4,932.91 16.6 0.005 36.0 0.013 1.67 0.24 47.66 4,936.87 4,936.87 4,936.87 4,936.87 0.00
P-96 (Storm K)SD INLET K1 (Storm K)FES K (Storm K)4,931.25 4,931.01 61.8 0.004 54.0 0.013 18.25 5.56 123.36 4,932.47 4,932.18 4,932.90 4,932.66 0.29
P-100 (Storm L)SD INLET L1 (Storm L)SD FES L (Storm L)4,932.23 4,932.01 55.3 0.004 -0.013 3.17 3.27 41.44 4,932.70 4,932.48 4,932.86 4,932.65 0.22
P-101 (Storm L)SD INLET L2 (Storm L)SD INLET L1 (Storm L)4,932.45 4,932.23 55.0 0.004 18.0 0.013 1.60 3.09 6.64 4,932.95 4,932.87 4,933.10 4,932.95 0.08
P-76 (Storm M)SDMH M6 (Storm M)SDMH M5 (Storm M)4,928.35 4,927.72 183.2 0.003 24.0 0.013 0.00 0.00 13.26 4,928.35 4,927.72 4,928.35 4,927.72 0.63
CO-43 SDMH M6 (Storm M)MH-45 4,928.35 4,928.75 119.6 -0.003 24.0 0.013 0.00 0.00 13.02 4,928.75 4,928.35 4,928.75 4,928.35 0.40
P-150 (Storm M)SD INLET M8 (Storm M)SDMH M7 (Storm M)4,928.76 4,928.79 6.0 -0.003 18.0 0.013 1.01 2.58 6.18 4,929.79 4,929.79 4,929.80 4,929.80 0.00
P-75 (Storm M)SDMH M5 (Storm M)SD INLET M4 (Storm M)4,927.72 4,927.06 193.1 0.003 24.0 0.013 0.00 0.00 13.26 4,927.72 4,927.60 4,927.72 4,927.60 0.13
P-102 (Storm M)SD INLET M4 (Storm M)SDMH M3 (Storm M)4,927.06 4,926.35 207.1 0.003 36.0 0.013 1.97 2.89 39.09 4,927.52 4,926.87 4,927.65 4,926.96 0.65
P-74 (Storm M)SDMH M3 (Storm M)SDMH M2 (Storm M)4,926.35 4,924.98 400.0 0.003 36.0 0.013 1.86 2.84 39.08 4,926.80 4,925.48 4,926.92 4,925.57 1.32
P-73 (Storm M)SDMH M2 (Storm M)SDMH M1 (Storm M)4,924.98 4,924.62 103.7 0.003 36.0 0.013 1.69 2.76 39.10 4,925.40 4,925.11 4,925.52 4,925.19 0.29
P-72 (Storm M)SDMH M1 (Storm M)O-6 4,924.62 4,924.21 125.7 0.003 36.0 0.013 1.65 2.69 38.13 4,925.05 4,924.61 4,925.16 4,924.74 0.44
CO-42 SDMH M-A1 (Storm M)O-7 4,924.68 4,924.40 133.4 0.002 48.0 0.013 0.00 0.00 196.23 4,924.68 4,924.40 4,924.68 4,924.40 0.28
P-186 (2) (Storm M)SD INLET M-A2 (Storm M)SDMH M-A1 (Storm M)4,925.57 4,924.68 444.2 0.002 48.0 0.013 0.00 0.00 192.71 4,925.57 4,924.68 4,925.57 4,924.68 0.89
P-148 (Storm M)SD OUTLET STRUCTURE M1.1 (Storm M)SDMH M1 (Storm M)4,925.01 4,924.62 30.1 0.013 18.0 0.013 0.00 0.00 11.95 4,925.07 4,925.07 4,925.07 4,925.07 0.00
P-187 (2) (Storm K)MH-39 SDMH K5 (Storm K)4,934.60 4,934.40 50.5 0.004 36.0 0.013 5.00 4.01 42.18 4,935.41 4,935.41 4,935.57 4,935.50 0.00
P-166 (Storm K)MH-40 SDMH K4 (Storm K)4,933.74 4,933.54 50.5 0.004 36.0 0.013 10.00 4.89 42.18 4,934.74 4,934.76 4,935.11 4,934.97 -0.01
P-106 (Storm C)MH-41 SDMH C2 (Storm C)4,933.75 4,933.28 47.2 0.010 18.0 0.013 0.85 3.58 10.50 4,934.09 4,933.57 4,934.21 4,933.77 0.53
P-151 (Storm M)MH-42 SDMH M7 (Storm M)4,930.50 4,930.26 46.5 0.005 18.0 0.013 1.02 2.95 7.43 4,930.87 4,930.64 4,931.01 4,930.78 0.23
P-149 (Storm M)MH-43 SD INLET M4 (Storm M)4,929.82 4,929.56 52.5 0.005 18.0 0.013 1.09 3.01 7.43 4,930.21 4,929.95 4,930.35 4,930.09 0.26
P-78 (Storm M)O-8 SD INLET M8 (Storm M)4,929.01 4,928.79 65.5 0.003 18.0 0.013 1.97 1.12 6.15 4,929.78 4,929.54 4,929.82 4,929.73 0.24
CO-44 MH-45 MH-46 4,928.75 4,929.00 --0.004 24.0 0.013 0.00 0.00 13.70 4,929.00 4,928.75 4,929.00 4,928.75 0.25
Page 1 of 1
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/fqmo52yf.xml
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm E_Split.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
P-137 (Storm I)SD AREA INLET I6.3 (Storm I)SD AREA INLET I6.2 (Storm I)4,944.91 4,944.71 40.1 0.005 18.0 0.013 2.16 3.64 7.43 4,945.49 4,945.49 4,945.67 4,945.57 0.01
P-136 (Storm I)SD AREA INLET I6.2 (Storm I)SD AREA INLET I6.1 (Storm I)4,944.50 4,942.98 304.0 0.005 24.0 0.013 2.14 3.54 16.00 4,945.01 4,944.11 4,945.19 4,944.13 0.90
P-143 (Storm I)SDMH I2-A.6 (Storm I)SDMH I2-A.5 (Storm I)4,942.10 4,941.60 134.8 0.004 24.0 0.013 2.40 3.29 13.78 4,943.08 4,943.07 4,943.12 4,943.08 0.01
P-159 (Storm I)SD AREA INLET I6.1-A (Storm I)SD AREA INLET I6.1 (Storm I)4,942.99 4,942.79 40.1 0.005 18.0 0.013 2.16 3.64 7.43 4,944.12 4,944.11 4,944.16 4,944.14 0.01
P-135 (Storm I)SD AREA INLET I6.1 (Storm I)SDMH I6 (Storm I)4,942.79 4,942.03 151.0 0.005 24.0 0.013 3.99 4.23 16.00 4,943.49 4,942.71 4,943.75 4,942.99 0.78
P-129 (Storm I)SD AREA INLET I5-A.2 (Storm I)SD AREA INLET I5-A.1 (Storm I)4,943.47 4,942.25 304.0 0.004 24.0 0.013 2.11 3.26 14.31 4,943.99 4,943.07 4,944.15 4,943.11 0.92
P-134 (Storm I)SD AREA INLET I6-A.2 (Storm I)SD AREA INLET I6-A.1 (Storm I)4,943.41 4,943.21 39.9 0.005 18.0 0.013 2.11 3.62 7.43 4,943.98 4,943.97 4,944.16 4,944.06 0.01
P-142 (Storm I)SDMH I2-A.5 (Storm I)SDMH I2-A.4 (Storm I)4,941.60 4,941.20 99.8 0.004 24.0 0.013 4.80 4.11 14.32 4,942.52 4,942.48 4,942.70 4,942.56 0.04
P-130 (Storm I)SD AREA INLET I5-A.3 (Storm I)SD AREA INLET I5-A.2 (Storm I)4,943.63 4,943.47 40.1 0.004 24.0 0.013 2.14 3.27 14.31 4,944.38 4,944.37 4,944.44 4,944.41 0.00
P-133 (Storm I)SD AREA INLET I6-A.1 (Storm I)SDMH I6 (Storm I)4,943.01 4,942.03 194.5 0.005 24.0 0.013 2.09 3.52 16.00 4,943.51 4,942.52 4,943.69 4,942.71 0.99
P-141 (Storm I)SDMH I2-A.4 (Storm I)SDMH I2-A.3 (Storm I)4,941.20 4,940.60 141.4 0.004 30.0 0.013 6.20 4.43 26.71 4,942.02 4,941.85 4,942.32 4,941.95 0.17
P-128 (Storm I)SD AREA INLET I5-A.1 (Storm I)SDMH I5 (Storm I)4,942.25 4,941.65 151.0 0.004 30.0 0.013 3.92 3.81 25.94 4,942.91 4,942.30 4,943.14 4,942.53 0.61
P-158 (Storm I)SD AREA INLET I5-A.1 (Storm I)SD AREA INLET I5-A.1-A (Storm I)4,942.45 4,942.25 40.1 0.005 24.0 0.013 2.14 0.68 16.00 4,943.19 4,943.09 4,943.22 4,943.19 0.10
P-53 (Storm I)SDMH I6 (Storm I)SDMH I5 (Storm I)4,940.07 4,939.68 96.0 0.004 36.0 0.013 5.77 4.20 42.51 4,941.36 4,941.35 4,941.42 4,941.39 0.00
P-50 (Storm I)SDMH I3 (Storm I)SDMH I2 (Storm I)4,937.56 4,937.45 24.8 0.004 54.0 0.013 15.75 5.56 130.92 4,939.07 4,939.08 4,939.25 4,939.22 -0.01
CO-36 SDMH I2 (Storm I)SD FES I (Storm I)4,937.39 4,937.00 -0.005 54.0 0.013 15.71 5.76 137.74 4,938.99 4,939.01 4,939.14 4,939.09 -0.02
P-131 (Storm I)SD AREA INLET I5.1 (Storm I)SDMH I5 (Storm I)4,942.62 4,941.65 194.5 0.005 30.0 0.013 2.12 3.44 29.00 4,943.10 4,942.11 4,943.26 4,942.29 0.99
P-132 (Storm I)SD AREA INLET I5.2 (Storm I)SD AREA INLET I5.1 (Storm I)4,943.02 4,942.82 39.9 0.005 24.0 0.013 2.14 3.54 16.00 4,943.53 4,943.39 4,943.71 4,943.52 0.14
P-124 (Storm I)SDMH I4.2 (Storm I)SDMH I4.1 (Storm I)4,940.22 4,939.30 235.0 0.004 36.0 0.013 4.00 3.73 41.73 4,940.85 4,940.71 4,941.06 4,940.74 0.13
P-140 (Storm I)SDMH I2-A.3 (Storm I)SDMH I2-A.2 (Storm I)4,940.60 4,940.40 51.0 0.004 36.0 0.013 7.60 4.49 41.78 4,941.77 4,941.76 4,941.91 4,941.86 0.00
CO-41 SDMH I2-A.1 (Storm I)O-4 4,939.70 4,939.50 -0.004 42.0 0.013 12.00 5.22 66.07 4,940.75 4,940.51 4,941.13 4,940.93 0.24
CO-26 SDMH I5 (Storm I)MH-28 4,939.68 4,939.20 120.4 0.004 42.0 0.013 11.33 4.99 63.52 4,940.76 4,940.78 4,941.07 4,940.90 -0.02
CO-32 SDMH I2-A.2 (Storm I)MH-33 4,940.40 4,939.95 108.0 0.004 36.0 0.013 9.00 4.82 43.05 4,941.68 4,941.68 4,941.83 4,941.75 0.00
CO-24 SDMH I4 (Storm I)MH-27 4,938.83 4,938.49 86.8 0.004 54.0 0.013 15.56 5.30 123.09 4,939.95 4,939.95 4,940.34 4,940.14 0.00
P-123 (Storm I)SDMH I4.1 (Storm I)SDMH I4 (Storm I)4,939.14 4,938.83 76.0 0.004 42.0 0.013 4.76 3.91 64.25 4,940.70 4,940.70 4,940.72 4,940.71 0.00
P-127 (Storm I)SD INLET I4.1-A.1 (Storm I)SDMH I4.1 (Storm I)4,940.42 4,940.30 28.5 0.004 24.0 0.013 0.54 2.22 14.68 4,940.72 4,940.71 4,940.77 4,940.73 0.01
P-126 (Storm I)SD INLET I4.1-A (Storm I)SDMH I4.1 (Storm I)4,940.80 4,940.85 8.5 -0.006 18.0 0.013 0.53 0.30 8.06 4,941.20 4,941.12 4,941.23 4,941.21 0.08
P-156 (Storm I)MH-1 SDMH I2-A.6 (Storm I)4,942.30 4,942.10 50.5 0.004 24.0 0.013 2.40 3.37 14.23 4,943.13 4,943.12 4,943.19 4,943.16 0.01
P-155 (Storm I)MH-2 SDMH I2-A.5 (Storm I)4,941.72 4,940.83 29.3 0.030 24.0 0.013 2.40 6.94 39.43 4,943.06 4,943.06 4,943.08 4,943.07 -0.01
P-154 (Storm I)MH-3 SDMH I2-A.4 (Storm I)4,941.68 4,941.53 30.5 0.005 18.0 0.013 1.40 3.21 7.36 4,942.46 4,942.45 4,942.49 4,942.48 0.00
P-153 (Storm I)MH-4 SDMH I2-A.3 (Storm I)4,941.11 4,940.96 30.5 0.005 18.0 0.013 1.40 3.21 7.37 4,941.82 4,941.82 4,941.87 4,941.85 0.00
P-152 (Storm I)MH-5 SDMH I2-A.2 (Storm I)4,940.41 4,940.26 31.2 0.005 24.0 0.013 1.40 3.09 15.70 4,941.73 4,941.73 4,941.73 4,941.73 0.00
P-125 (Storm I)MH-6 SDMH I4.2 (Storm I)4,943.44 4,943.33 21.5 0.005 24.0 0.013 2.33 3.63 16.00 4,943.97 4,943.85 4,944.16 4,944.05 0.12
CO-3 MH-8 SDMH J7 4,941.69 4,941.47 -0.009 18.0 0.013 1.00 3.54 9.70 4,942.06 4,941.99 4,942.20 4,942.04 0.08
CO-4 SDMH J7 SDMH J6 4,941.47 4,940.41 279.3 0.004 -0.013 1.00 2.40 13.39 4,941.77 4,941.11 4,941.86 4,941.12 0.66
CO-5 SDMH J6 MH-11 4,940.41 4,940.68 45.8 -0.006 18.0 0.013 1.00 3.11 8.07 4,941.11 4,941.12 4,941.20 4,941.14 -0.01
CO-6 SDMH J6 SDMH J5 4,940.41 4,939.98 93.2 0.005 -0.013 2.00 3.15 14.77 4,940.82 4,940.77 4,940.97 4,940.80 0.05
CO-9 SDMH J5 SDMH J4 4,939.98 4,939.69 74.8 0.004 -0.013 3.74 3.40 40.88 4,940.49 4,940.43 4,940.67 4,940.49 0.06
CO-7 SD Inlet J5-A SDMH J5 4,940.08 4,939.98 23.5 0.004 18.0 0.013 0.96 2.73 6.85 4,940.77 4,940.77 4,940.79 4,940.78 0.00
CO-8 SD Inlet J5.1 SDMH J5 4,941.02 4,940.90 -0.005 18.0 0.013 0.95 2.78 7.06 4,941.39 4,941.26 4,941.51 4,941.39 0.13
CO-13 SDMH J4 SDMH J3 4,939.69 4,938.85 210.6 0.004 -0.013 4.86 3.64 63.76 4,940.25 4,939.67 4,940.44 4,939.74 0.58
CO-10 SDMH J4.1 SDMH J4 4,940.01 4,939.69 79.8 0.004 36.0 0.013 1.30 2.69 42.23 4,940.41 4,940.40 4,940.49 4,940.42 0.01
CO-11 SDMH J4.1 SD Inlet J4.2 4,940.01 4,940.16 37.5 -0.004 18.0 0.013 0.79 2.53 6.64 4,940.51 4,940.45 4,940.61 4,940.50 0.06
CO-12 SDMH J4.1 SD Inlet J4.1 4,940.07 4,940.10 17.5 -0.002 24.0 0.013 0.61 1.68 9.37 4,940.46 4,940.44 4,940.50 4,940.48 0.02
CO-15 SDMH J3 SDMH J2 4,938.85 4,937.46 346.9 0.004 -0.013 5.82 3.84 63.90 4,939.46 4,939.03 4,939.68 4,939.05 0.43
CO-14 MH-20 SDMH J3 4,939.12 4,938.85 54.0 0.005 18.0 0.013 1.29 3.15 7.43 4,939.66 4,939.66 4,939.74 4,939.68 0.00
CO-17 SDMH J2 SD Inlet J1 4,937.46 4,937.37 23.5 0.004 -0.013 6.20 3.85 62.48 4,939.01 4,939.01 4,939.03 4,939.03 0.00
CO-16 SD Inlet J2.1 SDMH J2 4,940.50 4,940.30 29.5 0.007 -0.013 0.75 2.63 54.06 4,940.73 4,940.50 4,940.80 4,940.61 0.22
CO-18 SD Inlet J1 SD FES J 4,937.37 4,937.00 83.0 0.004 -0.013 7.78 4.34 66.38 4,939.00 4,939.00 4,939.03 4,939.02 0.00
CO-19 MH-24 SDMH I4.2 (Storm I)4,940.85 4,940.42 86.0 0.005 24.0 0.013 1.86 3.40 16.00 4,941.32 4,941.25 4,941.49 4,941.28 0.07
CO-20 MH-24 MH-25 4,941.05 4,941.20 --0.009 18.0 0.013 0.60 3.16 10.19 4,941.49 4,941.43 4,941.59 4,941.48 0.06
CO-21 MH-26 MH-24 4,941.10 4,941.05 10.6 0.005 18.0 0.013 1.29 3.09 7.21 4,941.53 4,941.51 4,941.68 4,941.63 0.02
CO-25 MH-27 SDMH I3 (Storm I)4,938.49 4,937.56 232.1 0.004 54.0 0.013 16.15 5.40 124.47 4,939.63 4,939.22 4,940.03 4,939.36 0.41
CO-31 MH-27 MH-32 4,938.69 4,938.73 8.5 -0.005 18.0 0.013 0.27 1.94 7.21 4,939.86 4,939.86 4,939.86 4,939.86 0.00
CO-27 MH-28 SDMH I4 (Storm I)4,939.20 4,938.83 93.3 0.004 48.0 0.013 11.10 4.89 90.45 4,940.72 4,940.72 4,940.82 4,940.78 0.00
CO-29 MH-28 MH-30 4,939.20 4,939.29 --0.006 18.0 0.013 0.93 3.04 8.05 4,940.74 4,940.74 4,940.74 4,940.74 0.00
CO-28 MH-29 MH-28 4,939.39 4,939.20 -0.005 18.0 0.013 0.83 2.72 7.23 4,940.74 4,940.74 4,940.74 4,940.74 0.00
CO-30 MH-31 MH-27 4,938.83 4,938.69 28.5 0.005 18.0 0.013 0.51 2.39 7.36 4,939.86 4,939.86 4,939.87 4,939.87 0.00
CO-33 MH-33 SDMH I2-A.1 (Storm I)4,939.95 4,939.70 70.7 0.004 42.0 0.013 12.02 4.86 59.82 4,941.62 4,941.62 4,941.73 4,941.70 0.01
CO-34 MH-33 SD INLET I2.1 (Storm I)4,937.85 4,937.99 28.5 -0.005 18.0 0.013 1.61 0.91 7.36 4,941.66 4,941.65 4,941.67 4,941.66 0.01
CO-35 MH-33 MH-35 4,937.85 4,937.90 9.3 -0.005 18.0 0.013 1.51 0.85 7.70 4,941.65 4,941.65 4,941.66 4,941.66 0.00
CO-37 SD FES D SD INLET D1 4,939.00 4,939.27 68.3 -0.004 24.0 0.013 2.62 3.45 14.22 4,939.85 4,939.56 4,940.04 4,939.77 0.29
CO-40 SD INLET D2 SD INLET D1 4,939.49 4,939.27 53.0 0.004 18.0 0.013 1.47 3.06 6.77 4,940.02 4,939.99 4,940.13 4,940.04 0.03
Page 1 of 1
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/v4krpam0.xml
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-4 4,951.40 HEC-22 Energy (Third Edition)0.00 4,943.46 4,943.46 4,943.66 4,943.78
MH-5 4,952.86 HEC-22 Energy (Third Edition)0.33 4,943.54 4,943.21 4,943.66 4,943.53
MH-6 4,948.88 HEC-22 Energy (Third Edition)0.00 4,943.75 4,943.75 4,943.89 4,943.88
MH-7 4,949.41 HEC-22 Energy (Third Edition)0.53 4,946.04 4,945.51 4,946.04 4,945.71
MH-9 4,949.30 HEC-22 Energy (Third Edition)0.00 4,946.07 4,946.07 4,946.16 4,946.16
MH-10 4,954.00 HEC-22 Energy (Third Edition)0.00 4,951.77 4,951.77 4,951.81 4,951.81
SD AREA INLET B2.1 (Storm B)4,943.19 HEC-22 Energy (Third Edition)0.00 4,942.60 4,942.60 4,942.88 4,942.88
SD AREA INLET F4-A.1 (Storm F)4,951.15 HEC-22 Energy (Third Edition)0.03 4,946.21 4,946.18 4,946.30 4,946.22
SD AREA INLET F4-A.2 (Storm F)4,950.68 HEC-22 Energy (Third Edition)0.00 4,946.33 4,946.33 4,946.53 4,946.53
SD AREA INLET F4.1 (Storm F)4,952.12 HEC-22 Energy (Third Edition)0.06 4,946.23 4,946.18 4,946.39 4,946.26
SD AREA INLET F4.2 (Storm F)4,951.77 HEC-22 Energy (Third Edition)0.00 4,946.50 4,946.50 4,946.69 4,946.69
SD AREA INLET F5.1 (Storm F)4,953.11 HEC-22 Energy (Third Edition)0.63 4,947.79 4,947.16 4,947.84 4,947.37
SD AREA INLET F5.2 (Storm F)4,953.32 HEC-22 Energy (Third Edition)0.00 4,947.82 4,947.82 4,947.90 4,947.90
SD AREA INLET F7 (Storm F)4,953.05 HEC-22 Energy (Third Edition)0.52 4,947.65 4,947.13 4,947.69 4,947.30
SD AREA INLET F8 (Storm F)4,953.45 HEC-22 Energy (Third Edition)0.00 4,947.68 4,947.68 4,947.73 4,947.73
SD AREA INLET G1 (Storm G)4,944.60 HEC-22 Energy (Third Edition)0.01 4,942.04 4,942.03 4,942.10 4,942.08
SD AREA INLET G4 (Storm G)4,951.82 HEC-22 Energy (Third Edition)0.00 4,947.87 4,947.87 4,948.20 4,948.20
SD INLET E3.1 (Storm E)4,948.61 HEC-22 Energy (Third Edition)0.00 4,945.10 4,945.10 4,945.16 4,945.16
SD INLET E3.1A (Storm E)4,948.61 HEC-22 Energy (Third Edition)0.00 4,945.09 4,945.09 4,945.11 4,945.11
SD INLET E4.1-1 (Storm E)4,948.96 HEC-22 Energy (Third Edition)0.00 4,945.63 4,945.63 4,945.67 4,945.67
SD INLET E4.2 (Storm E)4,948.96 HEC-22 Energy (Third Edition)0.00 4,945.65 4,945.65 4,945.80 4,945.80
SD INLET F1 (Storm F)4,948.85 HEC-22 Energy (Third Edition)0.23 4,943.58 4,943.35 4,943.70 4,943.70
SD INLET F2.1 (Storm F)4,948.85 HEC-22 Energy (Third Edition)0.00 4,943.72 4,943.72 4,943.73 4,943.73
SD INLET H5.1 (Storm H)4,951.61 HEC-22 Energy (Third Edition)0.00 4,946.75 4,946.75 4,946.83 4,946.83
SD INLET H5.1A (Storm H)4,951.61 HEC-22 Energy (Third Edition)0.00 4,946.73 4,946.73 4,946.75 4,946.75
SD Inlet F3-B 4,949.30 HEC-22 Energy (Third Edition)0.00 4,946.04 4,946.04 4,946.05 4,946.05
SD Inlet Z2.1-A 4,947.98 HEC-22 Energy (Third Edition)0.00 4,944.68 4,944.68 4,944.69 4,944.69
SD Inlet Z2.2 4,948.02 HEC-22 Energy (Third Edition)0.00 4,944.70 4,944.70 4,944.74 4,944.74
SD Inlet Z3-A 4,947.92 HEC-22 Energy (Third Edition)0.00 4,945.14 4,945.14 4,945.17 4,945.17
SD Inlet Z3.1 4,947.84 HEC-22 Energy (Third Edition)0.00 4,945.14 4,945.14 4,945.16 4,945.16
SD Inlet Z6 4,952.36 HEC-22 Energy (Third Edition)0.00 4,946.78 4,946.78 4,946.80 4,946.80
SD OUTLET STRUCTURE A3 (Storm A)4,946.01 HEC-22 Energy (Third Edition)0.00 4,944.09 4,944.09 4,944.24 4,944.24
SD OUTLET STRUCTURE B3.1 (Storm B)4,942.72 HEC-22 Energy (Third Edition)0.00 4,942.65 4,942.65 4,942.74 4,942.74
SD OUTLET STRUCTURE B8 (Storm B)4,944.76 HEC-22 Energy (Third Edition)0.00 4,942.59 4,942.59 4,942.60 4,942.60
SDMH A1 (Storm A)4,951.55 HEC-22 Energy (Third Edition)0.03 4,943.25 4,943.22 4,943.41 4,943.39
SDMH A2 (Storm A)4,952.98 HEC-22 Energy (Third Edition)0.03 4,943.97 4,943.94 4,944.12 4,944.09
SDMH B1 (Storm B)4,943.51 HEC-22 Energy (Third Edition)0.13 4,942.08 4,941.95 4,942.25 4,942.17
SDMH B2 (Storm B)4,944.17 HEC-22 Energy (Third Edition)0.07 4,942.40 4,942.33 4,942.46 4,942.50
SDMH B3 (Storm B)4,944.38 HEC-22 Energy (Third Edition)0.04 4,942.59 4,942.55 4,942.59 4,942.61
SDMH B4 (Storm B)4,946.10 HEC-22 Energy (Third Edition)0.00 4,942.59 4,942.59 4,942.59 4,942.59
SDMH B5 (Storm B)4,949.18 HEC-22 Energy (Third Edition)0.00 4,942.59 4,942.59 4,942.59 4,942.59
SDMH B6 (Storm B)4,952.02 HEC-22 Energy (Third Edition)0.00 4,942.59 4,942.59 4,942.59 4,942.59
SDMH B7 (Storm B)4,952.60 HEC-22 Energy (Third Edition)0.00 4,942.59 4,942.59 4,942.59 4,942.59
SDMH E1 (Storm E)4,949.96 HEC-22 Energy (Third Edition)0.62 4,944.43 4,943.82 4,944.51 4,944.14
SDMH E2 (Storm E)4,949.19 HEC-22 Energy (Third Edition)0.04 4,944.51 4,944.46 4,944.58 4,944.58
SDMH E3 (Storm E)4,948.52 HEC-22 Energy (Third Edition)0.38 4,945.07 4,944.69 4,945.10 4,944.98
SDMH E4 (Storm E)4,951.75 HEC-22 Energy (Third Edition)0.15 4,945.28 4,945.13 4,945.35 4,945.29
SDMH E4.1 (Storm E)4,948.76 HEC-22 Energy (Third Edition)0.20 4,945.59 4,945.39 4,945.64 4,945.60
SDMH E5 (Storm E)4,948.45 HEC-22 Energy (Third Edition)0.30 4,944.66 4,944.36 4,944.68 4,944.64
SDMH E6 (Storm E)4,947.77 HEC-22 Energy (Third Edition)0.46 4,945.12 4,944.66 4,945.14 4,944.84
SDMH E7 (Storm E)4,953.23 HEC-22 Energy (Third Edition)0.65 4,946.66 4,946.00 4,946.69 4,946.19
SDMH E8 (Storm E)4,952.16 HEC-22 Energy (Third Edition)0.09 4,946.77 4,946.68 4,946.79 4,946.80
SDMH F2 (Storm F)4,948.67 HEC-22 Energy (Third Edition)0.07 4,943.72 4,943.64 4,943.72 4,943.77
SDMH F3 (Storm F)4,950.56 HEC-22 Energy (Third Edition)0.20 4,945.15 4,944.95 4,945.17 4,945.25
SDMH F4 (Storm F)4,952.29 HEC-22 Energy (Third Edition)0.40 4,946.17 4,945.77 4,946.18 4,946.09
SDMH F5 (Storm F)4,953.34 HEC-22 Energy (Third Edition)0.37 4,946.69 4,946.32 4,946.72 4,946.56
SDMH F6 (Storm F)4,953.44 HEC-22 Energy (Third Edition)0.03 4,946.73 4,946.71 4,946.83 4,946.74
SDMH G2 (Storm G)4,953.56 HEC-22 Energy (Third Edition)0.84 4,944.97 4,944.13 4,945.05 4,944.41
SDMH G3 (Storm G)4,953.59 HEC-22 Energy (Third Edition)0.64 4,947.88 4,947.24 4,947.96 4,947.57
SDMH H1 (Storm H)4,956.30 HEC-22 Energy (Third Edition)0.26 4,944.90 4,944.64 4,945.03 4,944.94
SDMH H2 (Storm H)4,955.20 HEC-22 Energy (Third Edition)0.89 4,946.29 4,945.41 4,946.34 4,945.72
SDMH H3 (Storm H)4,952.64 HEC-22 Energy (Third Edition)0.02 4,946.36 4,946.34 4,946.47 4,946.46
SDMH H4 (Storm H)4,952.06 HEC-22 Energy (Third Edition)0.03 4,946.44 4,946.41 4,946.55 4,946.54
Page 1 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/gvrsnikj.xml
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm D_Eastern Pipes.stsw
SDMH H5 (Storm H)4,951.43 HEC-22 Energy (Third Edition)0.21 4,946.72 4,946.52 4,946.74 4,946.77
SDMH H6 (Storm H)4,951.56 HEC-22 Energy (Third Edition)0.01 4,946.74 4,946.74 4,946.77 4,946.77
SDMH H7 (Storm H)4,951.89 HEC-22 Energy (Third Edition)0.01 4,946.78 4,946.77 4,946.83 4,946.82
SDMH H8 (Storm H)4,952.23 HEC-22 Energy (Third Edition)0.02 4,946.84 4,946.82 4,946.92 4,946.91
SDMH Z2.1 4,948.14 HEC-22 Energy (Third Edition)0.01 4,944.68 4,944.67 4,944.68 4,944.72
Page 2 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/gvrsnikj.xml
Scenario: 100 Year
CO-27CO-14P-127(StormI)P-126(StormI)CO-16P-140(StormI)P-132(StormI)P-50(StormI)P-53(StormI)P-158(StormI)P-141(StormI)P-142(StormI)P-134(StormI)P-130(StormI)P-159(StormI)P-137(StormI)CO-17P-156(StormI)P-125(StormI)C
O
-3
6
CO-10CO-8CO-7CO-5CO-3CO-33CO-26CO-19CO-32CO-31CO-30CO-
1
8
C
O-41
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-16667/12/2022
Bentley StormCAD V8i (SELECTseries 4)
[08.11.04.54]Bentley Systems, Inc. Haestad Methods Solution CenterHFH022_Storm E_Split.stsw
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-1 4,948.00 HEC-22 Energy (Third Edition)0.00 4,943.13 4,943.13 4,943.19 4,943.19
MH-2 4,947.00 HEC-22 Energy (Third Edition)0.00 4,943.06 4,943.06 4,943.08 4,943.08
MH-3 4,947.00 HEC-22 Energy (Third Edition)0.00 4,942.46 4,942.46 4,942.49 4,942.49
MH-4 4,946.00 HEC-22 Energy (Third Edition)0.00 4,941.82 4,941.82 4,941.87 4,941.87
MH-5 4,945.00 HEC-22 Energy (Third Edition)0.00 4,941.73 4,941.73 4,941.73 4,941.73
MH-6 4,948.00 HEC-22 Energy (Third Edition)0.00 4,943.97 4,943.97 4,944.16 4,944.16
MH-8 4,946.51 HEC-22 Energy (Third Edition)0.00 4,942.06 4,942.06 4,942.20 4,942.20
MH-11 4,946.00 HEC-22 Energy (Third Edition)0.00 4,941.11 4,941.11 4,941.20 4,941.20
MH-20 4,945.56 HEC-22 Energy (Third Edition)0.00 4,939.66 4,939.66 4,939.74 4,939.74
MH-24 4,946.28 HEC-22 Energy (Third Edition)0.09 4,941.41 4,941.32 4,941.45 4,941.49
MH-25 4,946.49 HEC-22 Energy (Third Edition)0.00 4,941.49 4,941.49 4,941.59 4,941.59
MH-26 4,946.49 HEC-22 Energy (Third Edition)0.00 4,941.53 4,941.53 4,941.68 4,941.68
MH-27 4,945.76 HEC-22 Energy (Third Edition)0.23 4,939.86 4,939.63 4,939.86 4,940.03
MH-28 4,945.85 HEC-22 Energy (Third Edition)0.02 4,940.74 4,940.72 4,940.74 4,940.82
MH-29 4,946.49 HEC-22 Energy (Third Edition)0.00 4,940.74 4,940.74 4,940.74 4,940.74
MH-30 4,946.49 HEC-22 Energy (Third Edition)0.00 4,940.74 4,940.74 4,940.74 4,940.74
MH-31 4,945.93 HEC-22 Energy (Third Edition)0.00 4,939.86 4,939.86 4,939.87 4,939.87
MH-32 4,945.93 HEC-22 Energy (Third Edition)0.00 4,939.86 4,939.86 4,939.86 4,939.86
MH-33 4,946.64 HEC-22 Energy (Third Edition)0.02 4,941.65 4,941.62 4,941.66 4,941.73
MH-35 4,946.21 HEC-22 Energy (Third Edition)0.00 4,941.65 4,941.65 4,941.66 4,941.66
SD AREA INLET I5-A.1 (Storm I)4,947.29 HEC-22 Energy (Third Edition)0.13 4,943.04 4,942.91 4,943.09 4,943.14
SD AREA INLET I5-A.1-A (Storm I)4,947.01 HEC-22 Energy (Third Edition)0.00 4,943.19 4,943.19 4,943.22 4,943.22
SD AREA INLET I5-A.2 (Storm I)4,947.92 HEC-22 Energy (Third Edition)0.37 4,944.36 4,943.99 4,944.40 4,944.15
SD AREA INLET I5-A.3 (Storm I)4,947.66 HEC-22 Energy (Third Edition)0.00 4,944.38 4,944.38 4,944.44 4,944.44
SD AREA INLET I5.1 (Storm I)4,947.00 HEC-22 Energy (Third Edition)0.20 4,943.30 4,943.10 4,943.43 4,943.26
SD AREA INLET I5.2 (Storm I)4,946.88 HEC-22 Energy (Third Edition)0.00 4,943.53 4,943.53 4,943.71 4,943.71
SD AREA INLET I6-A.1 (Storm I)4,947.56 HEC-22 Energy (Third Edition)0.42 4,943.93 4,943.51 4,944.02 4,943.69
SD AREA INLET I6-A.2 (Storm I)4,947.91 HEC-22 Energy (Third Edition)0.00 4,943.98 4,943.98 4,944.16 4,944.16
SD AREA INLET I6.1 (Storm I)4,948.28 HEC-22 Energy (Third Edition)0.61 4,944.10 4,943.49 4,944.12 4,943.75
SD AREA INLET I6.1-A (Storm I)4,948.84 HEC-22 Energy (Third Edition)0.00 4,944.12 4,944.12 4,944.16 4,944.16
SD AREA INLET I6.2 (Storm I)4,949.07 HEC-22 Energy (Third Edition)0.44 4,945.45 4,945.01 4,945.53 4,945.19
SD AREA INLET I6.3 (Storm I)4,949.76 HEC-22 Energy (Third Edition)0.00 4,945.49 4,945.49 4,945.67 4,945.67
SD INLET D1 4,945.86 HEC-22 Energy (Third Edition)0.12 4,939.97 4,939.85 4,940.02 4,940.04
SD INLET D2 4,945.86 HEC-22 Energy (Third Edition)0.00 4,940.02 4,940.02 4,940.13 4,940.13
SD INLET I2.1 (Storm I)4,946.38 HEC-22 Energy (Third Edition)0.00 4,941.66 4,941.66 4,941.67 4,941.67
SD INLET I4.1-A (Storm I)4,945.81 HEC-22 Energy (Third Edition)0.00 4,941.20 4,941.20 4,941.23 4,941.23
SD INLET I4.1-A.1 (Storm I)4,945.81 HEC-22 Energy (Third Edition)0.00 4,940.72 4,940.72 4,940.77 4,940.77
SD Inlet J1 4,945.36 HEC-22 Energy (Third Edition)0.01 4,939.00 4,939.00 4,939.02 4,939.03
SD Inlet J2.1 4,945.36 HEC-22 Energy (Third Edition)0.00 4,940.73 4,940.73 4,940.80 4,940.80
SD Inlet J4.1 4,945.04 HEC-22 Energy (Third Edition)0.00 4,940.46 4,940.46 4,940.50 4,940.50
SD Inlet J4.2 4,945.07 HEC-22 Energy (Third Edition)0.00 4,940.51 4,940.51 4,940.61 4,940.61
SD Inlet J5-A 4,945.42 HEC-22 Energy (Third Edition)0.00 4,940.77 4,940.77 4,940.79 4,940.79
SD Inlet J5.1 4,945.42 HEC-22 Energy (Third Edition)0.00 4,941.39 4,941.39 4,941.51 4,941.51
SDMH I2 (Storm I)4,947.01 HEC-22 Energy (Third Edition)0.03 4,939.02 4,938.99 4,939.16 4,939.14
SDMH I2-A.1 (Storm I)4,946.69 HEC-22 Energy (Third Edition)0.84 4,941.59 4,940.75 4,941.66 4,941.13
SDMH I2-A.2 (Storm I)4,946.46 HEC-22 Energy (Third Edition)0.05 4,941.72 4,941.68 4,941.73 4,941.83
SDMH I2-A.3 (Storm I)4,946.72 HEC-22 Energy (Third Edition)0.04 4,941.81 4,941.77 4,941.84 4,941.91
SDMH I2-A.4 (Storm I)4,947.44 HEC-22 Energy (Third Edition)0.42 4,942.44 4,942.02 4,942.47 4,942.32
SDMH I2-A.5 (Storm I)4,947.84 HEC-22 Energy (Third Edition)0.54 4,943.06 4,942.52 4,943.07 4,942.70
SDMH I2-A.6 (Storm I)4,948.96 HEC-22 Energy (Third Edition)0.03 4,943.11 4,943.08 4,943.14 4,943.12
SDMH I3 (Storm I)4,947.08 HEC-22 Energy (Third Edition)0.08 4,939.15 4,939.07 4,939.30 4,939.25
SDMH I4 (Storm I)4,946.20 HEC-22 Energy (Third Edition)0.75 4,940.70 4,939.95 4,940.71 4,940.34
SDMH I4.1 (Storm I)4,946.10 HEC-22 Energy (Third Edition)0.00 4,940.71 4,940.70 4,940.73 4,940.72
SDMH I4.2 (Storm I)4,946.81 HEC-22 Energy (Third Edition)0.39 4,941.23 4,940.85 4,941.27 4,941.06
SDMH I5 (Storm I)4,946.55 HEC-22 Energy (Third Edition)0.58 4,941.34 4,940.76 4,941.37 4,941.07
SDMH I6 (Storm I)4,947.16 HEC-22 Energy (Third Edition)0.06 4,941.41 4,941.36 4,941.61 4,941.42
SDMH J2 4,945.50 HEC-22 Energy (Third Edition)0.01 4,939.02 4,939.01 4,939.04 4,939.03
SDMH J3 4,946.84 HEC-22 Energy (Third Edition)0.18 4,939.64 4,939.46 4,939.67 4,939.68
SDMH J4 4,945.86 HEC-22 Energy (Third Edition)0.15 4,940.40 4,940.25 4,940.41 4,940.44
SDMH J4.1 4,945.10 HEC-22 Energy (Third Edition)0.02 4,940.43 4,940.41 4,940.46 4,940.49
Page 1 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/irynyql4.xml
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm E_Split.stsw
SDMH J5 4,945.56 HEC-22 Energy (Third Edition)0.27 4,940.76 4,940.49 4,940.78 4,940.67
SDMH J6 4,945.90 HEC-22 Energy (Third Edition)0.29 4,941.11 4,940.82 4,941.12 4,940.97
SDMH J7 4,946.58 HEC-22 Energy (Third Edition)0.19 4,941.96 4,941.77 4,942.01 4,941.86
Page 2 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/irynyql4.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm D_Eastern Pipes.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
P-2 (Storm A)SDMH A2 (Storm A)SDMH A1 (Storm A)4,941.97 4,941.49 395.4 0.001 24.0 0.013 17.20 5.47 7.87 4,947.59 4,945.30 4,948.06 4,945.77 2.29
P-1 (Storm A)SDMH A1 (Storm A)SD FES A (Storm A)4,941.49 4,941.01 395.4 0.001 24.0 0.013 17.20 5.47 7.87 4,945.03 4,942.50 4,945.49 4,943.23 2.52
P-3 (Storm A)SD OUTLET STRUCTURE A3 (Storm A)SDMH A2 (Storm A)4,942.01 4,941.97 35.9 0.001 24.0 0.013 17.20 5.47 7.87 4,948.08 4,947.87 4,948.55 4,948.34 0.21
P-93 (Storm B)SDMH B7 (Storm B)SDMH B6 (Storm B)4,941.90 4,941.61 296.7 0.001 18.0 0.013 0.34 0.19 3.28 4,944.15 4,944.14 4,944.15 4,944.15 0.00
P-162 (Storm B)SDMH B6 (Storm B)SDMH B5 (Storm B)4,941.61 4,941.22 400.0 0.001 18.0 0.013 0.34 0.19 3.28 4,944.14 4,944.14 4,944.15 4,944.14 0.00
P-161 (Storm B)SDMH B5 (Storm B)SDMH B4 (Storm B)4,941.22 4,940.84 400.0 0.001 18.0 0.013 0.34 0.19 3.24 4,944.14 4,944.14 4,944.14 4,944.14 0.00
P-160 (Storm B)SDMH B4 (Storm B)SDMH B3 (Storm B)4,940.84 4,940.45 400.0 0.001 18.0 0.013 0.34 0.19 3.28 4,944.14 4,944.13 4,944.14 4,944.13 0.00
P-94 (Storm B)SD OUTLET STRUCTURE B8 (Storm B)SDMH B7 (Storm B)4,942.00 4,941.90 103.0 0.001 18.0 0.013 0.34 0.19 3.27 4,944.15 4,944.15 4,944.15 4,944.15 0.00
P-92 (Storm B)SDMH B3 (Storm B)SDMH B2 (Storm B)4,940.45 4,940.30 149.0 0.001 24.0 0.013 11.11 3.54 7.18 4,944.01 4,943.65 4,944.20 4,943.84 0.36
P-91 (Storm B)SDMH B2 (Storm B)SDMH B1 (Storm B)4,940.30 4,940.17 136.5 0.001 30.0 0.013 23.03 4.69 12.66 4,943.44 4,943.01 4,943.78 4,943.35 0.43
P-90 (Storm B)SDMH B1 (Storm B)SD FES B (Storm B)4,940.17 4,940.01 176.5 0.001 30.0 0.013 23.03 4.69 12.35 4,942.55 4,941.64 4,942.91 4,942.36 0.91
P-103 (Storm B)SD AREA INLET B2.1 (Storm B)SDMH B2 (Storm B)4,941.48 4,940.88 150.6 0.004 24.0 0.013 11.92 3.79 14.31 4,944.08 4,943.66 4,944.30 4,943.88 0.42
P-104 (Storm B)SD OUTLET STRUCTURE B3.1 (Storm B)SDMH B3 (Storm B)4,941.01 4,940.56 80.1 0.006 24.0 0.013 10.77 3.43 17.02 4,944.39 4,944.20 4,944.57 4,944.39 0.18
P-25 (Storm E)SDMH E7 (Storm E)SDMH E6 (Storm E)4,945.48 4,943.81 423.0 0.004 -0.013 15.62 2.91 25.57 4,948.34 4,947.71 4,948.49 4,947.87 0.63
P-26 (Storm E)SDMH E8 (Storm E)SDMH E7 (Storm E)4,945.91 4,945.48 107.0 0.004 30.0 0.013 15.95 3.25 26.00 4,948.67 4,948.51 4,948.83 4,948.67 0.16
CO-4 SDMH E5 (Storm E)MH-4 4,943.57 4,942.57 225.4 0.004 -0.013 38.55 3.95 60.53 4,947.11 4,946.70 4,947.39 4,946.99 0.41
P-27 (Storm E)SD Inlet Z6 SDMH E8 (Storm E)4,946.02 4,945.91 26.0 0.004 18.0 0.013 4.57 2.58 6.83 4,948.88 4,948.83 4,948.98 4,948.94 0.05
P-24 (Storm E)SDMH E6 (Storm E)SDMH E5 (Storm E)4,943.81 4,943.47 78.0 0.004 -0.013 33.26 4.33 43.35 4,947.50 4,947.30 4,947.85 4,947.64 0.20
P-22 (Storm E)SDMH E4 (Storm E)SDMH E3 (Storm E)4,944.50 4,943.89 186.5 0.003 -0.013 20.85 2.71 37.55 4,948.33 4,948.14 4,948.46 4,948.27 0.19
P-21 (Storm E)SDMH E3 (Storm E)SDMH E2 (Storm E)4,943.89 4,943.18 141.6 0.005 -0.013 39.57 5.08 47.26 4,947.99 4,947.49 4,948.46 4,947.96 0.50
P-110 (Storm E)SDMH E3 (Storm E)SD INLET E3.1A (Storm E)4,943.92 4,943.89 6.4 0.005 18.0 0.013 8.29 4.69 7.18 4,948.26 4,948.22 4,948.60 4,948.56 0.04
P-20 (Storm E)SDMH E2 (Storm E)SDMH E1 (Storm E)4,943.18 4,942.92 66.0 0.004 42.0 0.013 39.02 4.06 63.15 4,947.21 4,947.11 4,947.46 4,947.36 0.10
CO-6 SDMH E1 (Storm E)MH-5 4,942.92 4,942.32 148.9 0.004 42.0 0.013 38.71 4.02 63.86 4,946.84 4,946.62 4,947.09 4,946.87 0.22
P-112 (Storm E)SD Inlet Z3.1 SDMH E6 (Storm E)4,943.92 4,943.81 29.4 0.004 24.0 0.013 11.86 3.78 13.83 4,947.82 4,947.74 4,948.04 4,947.96 0.08
P-111 (Storm E)SD Inlet Z3-A SDMH E6 (Storm E)4,943.81 4,943.84 8.5 -0.004 18.0 0.013 10.01 5.66 6.24 4,947.85 4,947.77 4,948.35 4,948.27 0.08
P-114 (Storm E)SD INLET E4.2 (Storm E)SDMH E4.1 (Storm E)4,944.92 4,944.81 26.4 0.004 24.0 0.013 14.10 4.49 14.60 4,948.74 4,948.64 4,949.06 4,948.95 0.10
P-113 (Storm E)SDMH E4.1 (Storm E)SDMH E4 (Storm E)4,944.81 4,944.48 76.0 0.004 -0.013 21.20 2.77 43.01 4,948.49 4,948.41 4,948.63 4,948.55 0.08
P-115 (Storm E)SDMH E4.1 (Storm E)SD INLET E4.1-1 (Storm E)4,944.84 4,944.81 6.4 0.005 18.0 0.013 7.46 4.22 7.18 4,948.66 4,948.63 4,948.94 4,948.90 0.03
P-109 (Storm E)SD INLET E3.1 (Storm E)SDMH E3 (Storm E)4,944.00 4,943.89 26.4 0.004 24.0 0.013 15.50 4.93 14.60 4,948.36 4,948.23 4,948.74 4,948.61 0.12
P-34 (Storm F)SD AREA INLET F8 (Storm F)SD AREA INLET F7 (Storm F)4,946.75 4,946.55 40.1 0.005 18.0 0.013 9.42 5.33 7.43 4,952.48 4,952.15 4,952.92 4,952.60 0.32
P-32 (1) (Storm F)SDMH F6 (Storm F)SDMH F5 (Storm F)4,945.65 4,945.58 17.0 0.004 18.0 0.013 9.17 5.19 6.74 4,950.28 4,950.15 4,950.70 4,950.57 0.13
P-32 (Storm F)SDMH F5 (Storm F)SDMH F4 (Storm F)4,945.58 4,944.89 174.0 0.004 24.0 0.013 18.21 5.80 14.28 4,949.81 4,948.68 4,950.33 4,949.20 1.13
P-121 (Storm F)SD AREA INLET F5.2 (Storm F)SD AREA INLET F5.1 (Storm F)4,947.03 4,946.81 43.0 0.005 18.0 0.013 9.42 5.33 7.43 4,952.28 4,951.93 4,952.72 4,952.38 0.35
P-120 (Storm F)SD AREA INLET F5.1 (Storm F)SDMH F5 (Storm F)4,946.61 4,945.78 165.6 0.005 18.0 0.013 9.35 5.29 7.43 4,951.47 4,950.16 4,951.91 4,950.60 1.31
P-33 (Storm F)SD AREA INLET F7 (Storm F)SDMH F6 (Storm F)4,946.55 4,946.06 120.8 0.004 18.0 0.013 9.36 5.29 6.64 4,951.69 4,950.73 4,952.13 4,951.17 0.96
P-31 (Storm F)SDMH F4 (Storm F)SDMH F3 (Storm F)4,944.89 4,944.07 203.0 0.004 36.0 0.013 35.07 4.96 42.39 4,948.34 4,947.78 4,948.72 4,948.16 0.56
P-116 (Storm F)SD AREA INLET F4.1 (Storm F)SDMH F4 (Storm F)4,945.54 4,944.71 165.6 0.005 24.0 0.013 8.85 2.82 16.00 4,948.77 4,948.52 4,948.90 4,948.64 0.25
P-117 (Storm F)SD AREA INLET F4.2 (Storm F)SD AREA INLET F4.1 (Storm F)4,945.96 4,945.74 43.0 0.005 18.0 0.013 8.92 5.05 7.43 4,949.32 4,949.01 4,949.72 4,949.41 0.31
P-118 (Storm F)SD AREA INLET F4-A.1 (Storm F)SDMH F4 (Storm F)4,945.32 4,944.71 120.9 0.005 24.0 0.013 9.35 2.98 16.00 4,948.73 4,948.53 4,948.87 4,948.66 0.21
P-119 (Storm F)SD AREA INLET F4-A.2 (Storm F)SD AREA INLET F4-A.1 (Storm F)4,945.78 4,945.52 51.6 0.005 18.0 0.013 9.43 5.34 7.43 4,949.42 4,949.00 4,949.86 4,949.44 0.42
CO-8 SDMH F3 (Storm F)MH-6 4,944.07 4,942.60 415.1 0.004 42.0 0.013 35.91 3.73 59.87 4,947.57 4,947.04 4,947.79 4,947.26 0.53
P-81 (Storm F)SD INLET F2.1 (Storm F)SDMH F2 (Storm F)4,942.64 4,942.41 45.6 0.005 24.0 0.013 5.20 1.65 16.06 4,946.83 4,946.80 4,946.87 4,946.84 0.02
P-28 (Storm F)SD INLET F1 (Storm F)SD FES F (Storm F)4,942.38 4,942.00 81.0 0.005 42.0 0.013 44.01 4.57 68.91 4,946.48 4,946.32 4,946.80 4,946.65 0.16
P-29 (Storm F)SDMH F2 (Storm F)SD INLET F1 (Storm F)4,942.41 4,942.38 11.3 0.003 42.0 0.013 37.41 3.89 51.84 4,946.65 4,946.63 4,946.88 4,946.87 0.02
P-37 (Storm G)SDMH G3 (Storm G)SDMH G2 (Storm G)4,946.37 4,943.40 302.4 0.010 24.0 0.013 18.00 5.73 22.42 4,949.93 4,948.01 4,950.44 4,948.52 1.92
P-36 (Storm G)SDMH G2 (Storm G)SD AREA INLET G1 (Storm G)4,943.40 4,939.44 120.8 0.033 -0.013 18.00 5.36 39.36 4,947.62 4,946.79 4,948.14 4,947.31 0.83
P-38 (Storm G)SD AREA INLET G4 (Storm G)SDMH G3 (Storm G)4,947.00 4,946.37 64.3 0.010 24.0 0.013 18.00 5.73 22.39 4,950.72 4,950.31 4,951.23 4,950.82 0.41
P-35 (Storm G)SD AREA INLET G1 (Storm G)SD FES G (Storm G)4,939.44 4,939.00 22.1 0.020 -0.013 18.00 5.36 30.67 4,946.47 4,946.32 4,947.00 4,946.84 0.15
P-39 (Storm H)SDMH H1 (Storm H)SD FES H (Storm H)4,943.80 4,943.00 160.4 0.005 30.0 0.013 28.27 5.76 28.97 4,947.08 4,946.32 4,947.60 4,946.84 0.76
P-40 (Storm H)SDMH H2 (Storm H)SDMH H1 (Storm H)4,944.56 4,943.80 151.8 0.005 30.0 0.013 28.77 5.86 29.02 4,948.15 4,947.40 4,948.68 4,947.93 0.75
P-41 (Storm H)SDMH H3 (Storm H)SDMH H2 (Storm H)4,945.11 4,944.56 137.6 0.004 30.0 0.013 29.23 5.95 25.93 4,949.42 4,948.72 4,949.97 4,949.27 0.70
P-43 (Storm H)SDMH H5 (Storm H)SDMH H4 (Storm H)4,945.58 4,945.23 88.7 0.004 30.0 0.013 29.64 6.04 25.76 4,950.70 4,950.24 4,951.27 4,950.80 0.46
P-122 (Storm H)SDMH H5 (Storm H)SD INLET H5.1A (Storm H)4,945.62 4,945.58 6.5 0.006 18.0 0.013 6.50 3.68 8.24 4,950.92 4,950.90 4,951.13 4,951.11 0.02
P-42 (Storm H)SDMH H4 (Storm H)SDMH H3 (Storm H)4,945.23 4,945.11 29.5 0.004 30.0 0.013 29.33 5.98 26.15 4,949.90 4,949.75 4,950.46 4,950.30 0.15
P-46 (Storm H)SDMH H8 (Storm H)SDMH H7 (Storm H)4,946.17 4,945.96 52.8 0.004 18.0 0.013 7.82 4.43 6.63 4,952.09 4,951.79 4,952.39 4,952.10 0.29
P-45 (Storm H)SDMH H7 (Storm H)SDMH H6 (Storm H)4,945.96 4,945.71 61.8 0.004 18.0 0.013 7.75 4.38 6.68 4,951.61 4,951.28 4,951.91 4,951.58 0.34
P-44 (Storm H)SDMH H6 (Storm H)SDMH H5 (Storm H)4,945.71 4,945.58 31.6 0.004 18.0 0.013 7.66 4.33 6.74 4,951.10 4,950.93 4,951.39 4,951.22 0.17
P-79 (Storm H)SD INLET H5.1 (Storm H)SDMH H5 (Storm H)4,945.72 4,945.58 26.4 0.005 24.0 0.013 16.56 5.27 16.47 4,951.13 4,950.99 4,951.56 4,951.42 0.14
P-67 (Storm E)SD Inlet Z5.1 SDMH E8 (Storm E)4,945.94 4,945.91 6.6 0.005 24.0 0.013 12.18 3.88 15.20 4,948.90 4,948.88 4,949.14 4,949.12 0.02
P-47 (Storm H)SD Inlet H9 SDMH H8 (Storm H)4,946.93 4,946.17 190.2 0.004 18.0 0.013 8.10 4.59 6.64 4,953.36 4,952.23 4,953.69 4,952.56 1.13
CO-1 SDMH Z2.1 SDMH E5 (Storm E)4,943.80 4,943.47 -0.006 18.0 0.013 7.81 4.42 7.84 4,947.62 4,947.29 4,947.92 4,947.59 0.33
CO-3 SDMH Z2.1 SD Inlet Z2.1-A 4,943.80 4,943.83 --0.001 18.0 0.013 1.65 0.93 3.37 4,947.69 4,947.68 4,947.70 4,947.70 0.01
CO-2 SD Inlet Z2.2 SDMH Z2.1 4,943.91 4,943.80 28.6 0.004 18.0 0.013 6.38 3.61 6.52 4,947.86 4,947.76 4,948.07 4,947.96 0.11
CO-5 O-1 MH-4 4,942.00 4,942.57 143.0 -0.004 42.0 0.013 37.37 3.88 63.52 4,946.52 4,946.32 4,946.75 4,946.55 0.20
CO-7 MH-5 SD FES E (Storm E)4,942.32 4,942.00 80.8 0.004 42.0 0.013 38.02 3.95 63.31 4,946.44 4,946.32 4,946.68 4,946.56 0.12
CO-9 MH-6 SDMH F2 (Storm F)4,942.60 4,942.41 48.0 0.004 42.0 0.013 33.96 3.53 63.30 4,946.92 4,946.86 4,947.11 4,947.06 0.05
CO-10 MH-7 SDMH F3 (Storm F)4,944.94 4,943.87 212.8 0.005 24.0 0.013 11.48 3.65 16.04 4,948.26 4,947.71 4,948.46 4,947.92 0.55
CO-11 SD Inlet F3-B MH-7 4,945.32 4,945.13 37.5 0.005 18.0 0.013 2.37 1.34 7.48 4,948.44 4,948.43 4,948.47 4,948.45 0.02
CO-12 MH-9 MH-7 4,945.22 4,945.13 -0.006 18.0 0.013 10.86 6.15 7.91 4,948.82 4,948.65 4,949.41 4,949.24 0.17
CO-13 MH-10 O-2 4,951.61 4,951.41 -0.005 12.0 0.013 2.40 2.87 7.65 4,952.00 4,951.78 4,952.12 4,951.92 0.21
Page 1 of 1
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/y5tgsiqi.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
P-95 (Storm C)SDMH C4 (Storm C)SDMH C3 (Storm C)4,937.66 4,933.56 413.3 0.010 18.0 0.013 11.20 6.34 10.47 4,941.27 4,936.57 4,941.89 4,937.19 4.70
P-10 (Storm C)SD OUTLET STRUCTURE C5 (Storm C)SDMH C4 (Storm C)4,939.01 4,937.66 136.0 0.010 18.0 0.013 11.20 6.34 10.46 4,943.35 4,941.81 4,943.98 4,942.43 1.55
P-71 (Storm C)SD INLET C3.1 (Storm C)SDMH C3 (Storm C)4,933.79 4,933.56 47.0 0.005 36.0 0.013 3.06 3.76 47.16 4,936.32 4,936.32 4,936.33 4,936.33 0.00
P-107 (Storm C)SDMH C3 (Storm C)SD INLET C3.1A (Storm C)4,933.59 4,933.56 6.0 0.005 36.0 0.013 2.81 0.40 47.16 4,936.32 4,936.32 4,936.32 4,936.32 0.00
P-70 (Storm C)SDMH C3 (Storm C)SDMH C2 (Storm C)4,933.56 4,931.78 356.0 0.005 -0.013 17.01 2.21 46.61 4,936.28 4,936.05 4,936.37 4,936.13 0.24
P-105 (Storm C)SDMH C2 (Storm C)SD INLET C2.1A (Storm C)4,933.34 4,933.28 6.0 0.010 18.0 0.013 3.73 2.11 10.50 4,936.04 4,936.04 4,936.11 4,936.11 0.01
P-69 (Storm C)SDMH C2 (Storm C)SDMH C1 (Storm C)4,931.78 4,929.84 388.1 0.005 36.0 0.013 22.91 3.24 47.16 4,935.94 4,935.49 4,936.11 4,935.65 0.46
P-68 (Storm C)SDMH C1 (Storm C)STORM FES C (Storm C)4,929.84 4,929.39 63.5 0.007 36.0 0.013 22.09 3.13 56.17 4,935.29 4,935.22 4,935.44 4,935.37 0.07
P-99 (Storm K)SDMH K4 (Storm K)SDMH K3 (Storm K)4,932.89 4,932.17 180.9 0.004 54.0 0.013 85.00 5.34 124.36 4,937.62 4,937.28 4,938.07 4,937.73 0.34
P-187 (1) (Storm K)SDMH K5 (Storm K)SDMH K4 (Storm K)4,934.40 4,932.89 377.1 0.004 42.0 0.013 25.00 2.60 63.63 4,938.18 4,937.95 4,938.29 4,938.06 0.23
P-98 (Storm K)SDMH K3 (Storm K)SDMH K2 (Storm K)4,932.17 4,931.41 186.6 0.004 54.0 0.013 85.00 5.34 125.62 4,937.01 4,936.66 4,937.46 4,937.11 0.35
P-97 (Storm K)SDMH K2 (Storm K)SD INLET K1 (Storm K)4,931.41 4,931.25 38.4 0.004 54.0 0.013 92.13 5.79 123.79 4,936.19 4,936.10 4,936.71 4,936.62 0.08
P-147 (Storm K)SD INLET K2.1 (Storm K)SDMH K2 (Storm K)4,932.99 4,932.91 16.6 0.005 36.0 0.013 7.19 1.02 47.66 4,936.49 4,936.49 4,936.51 4,936.51 0.00
P-96 (Storm K)SD INLET K1 (Storm K)FES K (Storm K)4,931.25 4,931.01 61.8 0.004 54.0 0.013 99.34 8.63 123.36 4,935.33 4,935.22 4,936.00 4,935.86 0.11
P-100 (Storm L)SD INLET L1 (Storm L)SD FES L (Storm L)4,932.23 4,932.01 55.3 0.004 -0.013 13.89 1.80 41.44 4,935.24 4,935.22 4,935.30 4,935.28 0.02
P-101 (Storm L)SD INLET L2 (Storm L)SD INLET L1 (Storm L)4,932.45 4,932.23 55.0 0.004 18.0 0.013 6.99 3.96 6.64 4,935.60 4,935.36 4,935.84 4,935.60 0.24
P-76 (Storm M)SDMH M6 (Storm M)SDMH M5 (Storm M)4,928.35 4,927.72 183.2 0.003 24.0 0.013 21.50 6.84 13.26 4,934.07 4,932.41 4,934.80 4,933.14 1.65
CO-43 SDMH M6 (Storm M)MH-45 4,928.35 4,928.75 119.6 -0.003 24.0 0.013 21.50 6.84 13.02 4,935.58 4,934.50 4,936.31 4,935.23 1.08
P-150 (Storm M)SD INLET M8 (Storm M)SDMH M7 (Storm M)4,928.76 4,928.79 6.0 -0.003 18.0 0.013 4.40 2.49 6.18 4,930.90 4,930.89 4,930.99 4,930.98 0.01
P-75 (Storm M)SDMH M5 (Storm M)SD INLET M4 (Storm M)4,927.72 4,927.06 193.1 0.003 24.0 0.013 21.50 6.84 13.26 4,931.97 4,930.22 4,932.69 4,930.95 1.74
P-102 (Storm M)SD INLET M4 (Storm M)SDMH M3 (Storm M)4,927.06 4,926.35 207.1 0.003 36.0 0.013 30.16 6.10 39.09 4,929.60 4,929.28 4,929.94 4,929.57 0.32
P-74 (Storm M)SDMH M3 (Storm M)SDMH M2 (Storm M)4,926.35 4,924.98 400.0 0.003 36.0 0.013 29.92 6.09 39.08 4,929.09 4,928.33 4,929.39 4,928.61 0.76
P-73 (Storm M)SDMH M2 (Storm M)SDMH M1 (Storm M)4,924.98 4,924.62 103.7 0.003 36.0 0.013 29.51 4.18 39.10 4,928.16 4,927.96 4,928.43 4,928.23 0.20
P-72 (Storm M)SDMH M1 (Storm M)O-6 4,924.62 4,924.21 125.7 0.003 36.0 0.013 31.37 4.44 38.13 4,927.78 4,927.50 4,928.08 4,927.81 0.28
CO-42 SDMH M-A1 (Storm M)O-7 4,924.68 4,924.40 133.4 0.002 48.0 0.013 217.00 5.76 196.23 4,928.74 4,928.40 4,929.25 4,928.92 0.34
P-186 (2) (Storm M)SD INLET M-A2 (Storm M)SDMH M-A1 (Storm M)4,925.57 4,924.68 444.2 0.002 48.0 0.013 217.00 5.76 192.71 4,930.35 4,929.22 4,930.86 4,929.74 1.13
P-148 (Storm M)SD OUTLET STRUCTURE M1.1 (Storm M)SDMH M1 (Storm M)4,925.01 4,924.62 30.1 0.013 18.0 0.013 2.00 1.13 11.95 4,927.87 4,927.86 4,927.89 4,927.88 0.01
P-187 (2) (Storm K)MH-39 SDMH K5 (Storm K)4,934.60 4,934.40 50.5 0.004 36.0 0.013 25.00 3.54 42.18 4,938.03 4,937.96 4,938.22 4,938.15 0.07
P-166 (Storm K)MH-40 SDMH K4 (Storm K)4,933.74 4,933.54 50.5 0.004 36.0 0.013 60.00 8.49 42.18 4,938.77 4,938.36 4,939.89 4,939.48 0.41
P-106 (Storm C)MH-41 SDMH C2 (Storm C)4,933.75 4,933.28 47.2 0.010 18.0 0.013 3.67 2.08 10.50 4,936.09 4,936.04 4,936.16 4,936.10 0.06
P-151 (Storm M)MH-42 SDMH M7 (Storm M)4,930.50 4,930.26 46.5 0.005 18.0 0.013 4.44 4.39 7.43 4,931.33 4,931.16 4,931.63 4,931.41 0.18
P-149 (Storm M)MH-43 SD INLET M4 (Storm M)4,929.82 4,929.56 52.5 0.005 18.0 0.013 4.75 4.46 7.43 4,931.27 4,931.17 4,931.38 4,931.28 0.10
P-78 (Storm M)O-8 SD INLET M8 (Storm M)4,929.01 4,928.79 65.5 0.003 18.0 0.013 8.64 4.89 6.15 4,930.77 4,930.15 4,931.14 4,930.71 0.62
CO-44 MH-45 MH-46 4,928.75 4,929.00 --0.004 24.0 0.013 21.50 6.84 13.70 4,936.64 4,936.02 4,937.36 4,936.75 0.62
Page 1 of 1
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/1pazrkjg.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm E_Split.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
P-137 (Storm I)SD AREA INLET I6.3 (Storm I)SD AREA INLET I6.2 (Storm I)4,944.91 4,944.71 40.1 0.005 18.0 0.013 9.42 5.33 7.43 4,949.19 4,948.86 4,949.63 4,949.31 0.32
P-136 (Storm I)SD AREA INLET I6.2 (Storm I)SD AREA INLET I6.1 (Storm I)4,944.50 4,942.98 304.0 0.005 24.0 0.013 9.36 2.98 16.00 4,948.57 4,948.05 4,948.71 4,948.19 0.52
P-143 (Storm I)SDMH I2-A.6 (Storm I)SDMH I2-A.5 (Storm I)4,942.10 4,941.60 134.8 0.004 24.0 0.013 7.00 2.23 13.78 4,947.97 4,947.84 4,948.05 4,947.92 0.13
P-159 (Storm I)SD AREA INLET I6.1-A (Storm I)SD AREA INLET I6.1 (Storm I)4,942.99 4,942.79 40.1 0.005 18.0 0.013 9.42 5.33 7.43 4,948.50 4,948.17 4,948.94 4,948.62 0.32
P-135 (Storm I)SD AREA INLET I6.1 (Storm I)SDMH I6 (Storm I)4,942.79 4,942.03 151.0 0.005 24.0 0.013 17.21 5.48 16.00 4,947.75 4,946.87 4,948.21 4,947.34 0.87
P-129 (Storm I)SD AREA INLET I5-A.2 (Storm I)SD AREA INLET I5-A.1 (Storm I)4,943.47 4,942.25 304.0 0.004 24.0 0.013 9.16 2.91 14.31 4,947.22 4,946.72 4,947.35 4,946.86 0.50
P-134 (Storm I)SD AREA INLET I6-A.2 (Storm I)SD AREA INLET I6-A.1 (Storm I)4,943.41 4,943.21 39.9 0.005 18.0 0.013 9.29 5.26 7.43 4,947.66 4,947.35 4,948.09 4,947.78 0.31
P-142 (Storm I)SDMH I2-A.5 (Storm I)SDMH I2-A.4 (Storm I)4,941.60 4,941.20 99.8 0.004 24.0 0.013 14.00 4.46 14.32 4,947.62 4,947.24 4,947.93 4,947.54 0.38
P-130 (Storm I)SD AREA INLET I5-A.3 (Storm I)SD AREA INLET I5-A.2 (Storm I)4,943.63 4,943.47 40.1 0.004 24.0 0.013 9.27 2.95 14.31 4,947.45 4,947.39 4,947.59 4,947.52 0.07
P-133 (Storm I)SD AREA INLET I6-A.1 (Storm I)SDMH I6 (Storm I)4,943.01 4,942.03 194.5 0.005 24.0 0.013 9.23 2.94 16.00 4,947.06 4,946.74 4,947.20 4,946.88 0.32
P-141 (Storm I)SDMH I2-A.4 (Storm I)SDMH I2-A.3 (Storm I)4,941.20 4,940.60 141.4 0.004 30.0 0.013 21.00 4.28 26.71 4,947.00 4,946.63 4,947.28 4,946.91 0.37
P-128 (Storm I)SD AREA INLET I5-A.1 (Storm I)SDMH I5 (Storm I)4,942.25 4,941.65 151.0 0.004 30.0 0.013 16.91 3.45 25.94 4,946.63 4,946.38 4,946.82 4,946.56 0.26
P-158 (Storm I)SD AREA INLET I5-A.1 (Storm I)SD AREA INLET I5-A.1-A (Storm I)4,942.45 4,942.25 40.1 0.005 24.0 0.013 9.37 2.98 16.00 4,946.79 4,946.73 4,946.93 4,946.86 0.07
P-53 (Storm I)SDMH I6 (Storm I)SDMH I5 (Storm I)4,940.07 4,939.68 96.0 0.004 36.0 0.013 25.16 3.56 42.51 4,946.52 4,946.38 4,946.72 4,946.58 0.14
P-50 (Storm I)SDMH I3 (Storm I)SDMH I2 (Storm I)4,937.56 4,937.45 24.8 0.004 54.0 0.013 67.15 4.22 130.92 4,944.40 4,944.37 4,944.67 4,944.65 0.03
CO-36 SDMH I2 (Storm I)SD FES I (Storm I)4,937.39 4,937.00 -0.005 54.0 0.013 66.93 4.21 137.74 4,944.20 4,944.11 4,944.48 4,944.39 0.09
P-131 (Storm I)SD AREA INLET I5.1 (Storm I)SDMH I5 (Storm I)4,942.62 4,941.65 194.5 0.005 30.0 0.013 9.19 1.87 29.00 4,946.42 4,946.32 4,946.48 4,946.38 0.10
P-132 (Storm I)SD AREA INLET I5.2 (Storm I)SD AREA INLET I5.1 (Storm I)4,943.02 4,942.82 39.9 0.005 24.0 0.013 9.29 2.96 16.00 4,946.59 4,946.52 4,946.73 4,946.66 0.07
P-124 (Storm I)SDMH I4.2 (Storm I)SDMH I4.1 (Storm I)4,940.22 4,939.30 235.0 0.004 36.0 0.013 16.70 2.36 41.73 4,945.63 4,945.49 4,945.72 4,945.57 0.15
P-140 (Storm I)SDMH I2-A.3 (Storm I)SDMH I2-A.2 (Storm I)4,940.60 4,940.40 51.0 0.004 36.0 0.013 30.25 4.28 41.78 4,946.40 4,946.30 4,946.69 4,946.58 0.10
CO-41 SDMH I2-A.1 (Storm I)O-4 4,939.70 4,939.50 -0.004 42.0 0.013 54.51 5.67 66.07 4,944.64 4,944.50 4,945.14 4,945.00 0.14
CO-26 SDMH I5 (Storm I)MH-28 4,939.68 4,939.20 120.4 0.004 42.0 0.013 49.14 5.11 63.52 4,946.08 4,945.79 4,946.48 4,946.20 0.29
CO-32 SDMH I2-A.2 (Storm I)MH-33 4,940.40 4,939.95 108.0 0.004 36.0 0.013 39.50 5.59 43.05 4,946.01 4,945.63 4,946.50 4,946.12 0.38
CO-24 SDMH I4 (Storm I)MH-27 4,938.83 4,938.49 86.8 0.004 54.0 0.013 66.53 4.18 123.09 4,945.20 4,945.10 4,945.47 4,945.37 0.10
P-123 (Storm I)SDMH I4.1 (Storm I)SDMH I4 (Storm I)4,939.14 4,938.83 76.0 0.004 42.0 0.013 19.46 2.02 64.25 4,945.44 4,945.41 4,945.50 4,945.47 0.03
P-127 (Storm I)SD INLET I4.1-A.1 (Storm I)SDMH I4.1 (Storm I)4,940.42 4,940.30 28.5 0.004 24.0 0.013 2.31 0.74 14.68 4,945.46 4,945.45 4,945.47 4,945.46 0.00
P-126 (Storm I)SD INLET I4.1-A (Storm I)SDMH I4.1 (Storm I)4,940.80 4,940.85 8.5 -0.006 18.0 0.013 2.15 1.21 8.06 4,945.46 4,945.46 4,945.49 4,945.48 0.00
P-156 (Storm I)MH-1 SDMH I2-A.6 (Storm I)4,942.30 4,942.10 50.5 0.004 24.0 0.013 7.00 2.23 14.23 4,948.12 4,948.07 4,948.19 4,948.15 0.05
P-155 (Storm I)MH-2 SDMH I2-A.5 (Storm I)4,941.72 4,940.83 29.3 0.030 24.0 0.013 7.00 2.23 39.43 4,947.87 4,947.84 4,947.95 4,947.92 0.03
P-154 (Storm I)MH-3 SDMH I2-A.4 (Storm I)4,941.68 4,941.53 30.5 0.005 18.0 0.013 7.00 3.96 7.36 4,947.34 4,947.21 4,947.59 4,947.45 0.14
P-153 (Storm I)MH-4 SDMH I2-A.3 (Storm I)4,941.11 4,940.96 30.5 0.005 18.0 0.013 9.25 5.23 7.37 4,946.92 4,946.68 4,947.35 4,947.11 0.24
P-152 (Storm I)MH-5 SDMH I2-A.2 (Storm I)4,940.41 4,940.26 31.2 0.005 24.0 0.013 9.25 2.94 15.70 4,946.29 4,946.24 4,946.43 4,946.37 0.05
P-125 (Storm I)MH-6 SDMH I4.2 (Storm I)4,943.44 4,943.33 21.5 0.005 24.0 0.013 10.14 3.23 16.00 4,945.82 4,945.77 4,945.98 4,945.93 0.04
CO-3 MH-8 SDMH J7 4,941.69 4,941.47 -0.009 18.0 0.013 4.50 2.55 9.70 4,945.35 4,945.30 4,945.45 4,945.40 0.05
CO-4 SDMH J7 SDMH J6 4,941.47 4,940.41 279.3 0.004 -0.013 4.50 1.34 13.39 4,945.24 4,945.12 4,945.27 4,945.15 0.12
CO-5 SDMH J6 MH-11 4,940.41 4,940.68 45.8 -0.006 18.0 0.013 4.50 2.55 8.07 4,945.23 4,945.14 4,945.33 4,945.24 0.08
CO-6 SDMH J6 SDMH J5 4,940.41 4,939.98 93.2 0.005 -0.013 9.00 2.68 14.77 4,945.06 4,944.90 4,945.19 4,945.03 0.16
CO-9 SDMH J5 SDMH J4 4,939.98 4,939.69 74.8 0.004 -0.013 16.46 2.14 40.88 4,944.81 4,944.77 4,944.90 4,944.85 0.05
CO-7 SD Inlet J5-A SDMH J5 4,940.08 4,939.98 23.5 0.004 18.0 0.013 4.08 2.31 6.85 4,944.91 4,944.88 4,944.99 4,944.96 0.04
CO-8 SD Inlet J5.1 SDMH J5 4,941.02 4,940.90 -0.005 18.0 0.013 4.12 2.33 7.06 4,944.92 4,944.88 4,945.00 4,944.96 0.04
CO-13 SDMH J4 SDMH J3 4,939.69 4,938.85 210.6 0.004 -0.013 20.69 1.95 63.76 4,944.72 4,944.63 4,944.79 4,944.70 0.09
CO-10 SDMH J4.1 SDMH J4 4,940.01 4,939.69 79.8 0.004 36.0 0.013 5.44 0.77 42.23 4,944.74 4,944.74 4,944.75 4,944.75 0.01
CO-11 SDMH J4.1 SD Inlet J4.2 4,940.01 4,940.16 37.5 -0.004 18.0 0.013 3.48 1.97 6.64 4,944.81 4,944.77 4,944.87 4,944.83 0.04
CO-12 SDMH J4.1 SD Inlet J4.1 4,940.07 4,940.10 17.5 -0.002 24.0 0.013 2.38 0.76 9.37 4,944.75 4,944.75 4,944.76 4,944.76 0.00
CO-15 SDMH J3 SDMH J2 4,938.85 4,937.46 346.9 0.004 -0.013 24.36 2.30 63.90 4,944.58 4,944.38 4,944.68 4,944.48 0.20
CO-14 MH-20 SDMH J3 4,939.12 4,938.85 54.0 0.005 18.0 0.013 5.62 3.18 7.43 4,944.82 4,944.67 4,944.98 4,944.82 0.15
CO-17 SDMH J2 SD Inlet J1 4,937.46 4,937.37 23.5 0.004 -0.013 24.90 2.35 62.48 4,944.28 4,944.26 4,944.38 4,944.36 0.01
CO-16 SD Inlet J2.1 SDMH J2 4,940.50 4,940.30 29.5 0.007 -0.013 2.26 0.29 54.06 4,944.34 4,944.34 4,944.34 4,944.34 0.00
CO-18 SD Inlet J1 SD FES J 4,937.37 4,937.00 83.0 0.004 -0.013 30.97 2.95 66.38 4,944.19 4,944.11 4,944.35 4,944.27 0.08
CO-19 MH-24 SDMH I4.2 (Storm I)4,940.85 4,940.42 86.0 0.005 24.0 0.013 7.32 2.33 16.00 4,945.83 4,945.74 4,945.92 4,945.83 0.09
CO-20 MH-24 MH-25 4,941.05 4,941.20 --0.009 18.0 0.013 2.62 1.48 10.19 4,945.87 4,945.86 4,945.91 4,945.90 0.01
CO-21 MH-26 MH-24 4,941.10 4,941.05 10.6 0.005 18.0 0.013 4.85 2.74 7.21 4,945.92 4,945.90 4,946.03 4,946.01 0.02
CO-25 MH-27 SDMH I3 (Storm I)4,938.49 4,937.56 232.1 0.004 54.0 0.013 69.21 4.35 124.47 4,944.93 4,944.65 4,945.23 4,944.94 0.29
CO-31 MH-27 MH-32 4,938.69 4,938.73 8.5 -0.005 18.0 0.013 1.49 0.85 7.21 4,945.00 4,945.00 4,945.01 4,945.01 0.00
CO-27 MH-28 SDMH I4 (Storm I)4,939.20 4,938.83 93.3 0.004 48.0 0.013 48.30 3.84 90.45 4,945.58 4,945.48 4,945.81 4,945.71 0.11
CO-29 MH-28 MH-30 4,939.20 4,939.29 --0.006 18.0 0.013 4.07 2.30 8.05 4,945.68 4,945.66 4,945.77 4,945.74 0.02
CO-28 MH-29 MH-28 4,939.39 4,939.20 -0.005 18.0 0.013 3.59 2.03 7.23 4,945.70 4,945.65 4,945.76 4,945.72 0.05
CO-30 MH-31 MH-27 4,938.83 4,938.69 28.5 0.005 18.0 0.013 2.22 1.26 7.36 4,945.01 4,945.00 4,945.04 4,945.03 0.01
CO-33 MH-33 SDMH I2-A.1 (Storm I)4,939.95 4,939.70 70.7 0.004 42.0 0.013 54.61 5.68 59.82 4,945.34 4,945.13 4,945.84 4,945.63 0.21
CO-34 MH-33 SD INLET I2.1 (Storm I)4,937.85 4,937.99 28.5 -0.005 18.0 0.013 6.23 3.52 7.36 4,945.62 4,945.52 4,945.81 4,945.71 0.10
CO-35 MH-33 MH-35 4,937.85 4,937.90 9.3 -0.005 18.0 0.013 9.22 5.22 7.70 4,945.68 4,945.61 4,946.10 4,946.03 0.07
CO-37 SD FES D SD INLET D1 4,939.00 4,939.27 68.3 -0.004 24.0 0.013 11.49 3.66 14.22 4,944.29 4,944.11 4,944.49 4,944.32 0.18
CO-40 SD INLET D2 SD INLET D1 4,939.49 4,939.27 53.0 0.004 18.0 0.013 6.46 3.66 6.77 4,944.61 4,944.41 4,944.82 4,944.62 0.20
Page 1 of 1
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/3hx2yamj.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-4 4,951.40 HEC-22 Energy (Third Edition)0.07 4,946.59 4,946.52 4,946.87 4,946.75
MH-5 4,952.86 HEC-22 Energy (Third Edition)0.09 4,946.52 4,946.44 4,946.77 4,946.68
MH-6 4,948.88 HEC-22 Energy (Third Edition)0.04 4,946.96 4,946.92 4,947.17 4,947.11
MH-7 4,949.41 HEC-22 Energy (Third Edition)0.16 4,948.41 4,948.26 4,948.44 4,948.46
MH-9 4,949.30 HEC-22 Energy (Third Edition)0.00 4,948.82 4,948.82 4,949.41 4,949.41
MH-10 4,954.00 HEC-22 Energy (Third Edition)0.00 4,952.00 4,952.00 4,952.12 4,952.12
SD AREA INLET B2.1 (Storm B)4,943.19 HEC-22 Energy (Third Edition)0.00 4,943.19 4,943.19 4,943.41 4,943.41
SD AREA INLET F4-A.1 (Storm F)4,951.15 HEC-22 Energy (Third Edition)0.09 4,948.82 4,948.73 4,949.27 4,948.87
SD AREA INLET F4-A.2 (Storm F)4,950.68 HEC-22 Energy (Third Edition)0.00 4,949.42 4,949.42 4,949.86 4,949.86
SD AREA INLET F4.1 (Storm F)4,952.12 HEC-22 Energy (Third Edition)0.08 4,948.85 4,948.77 4,949.25 4,948.90
SD AREA INLET F4.2 (Storm F)4,951.77 HEC-22 Energy (Third Edition)0.00 4,949.32 4,949.32 4,949.72 4,949.72
SD AREA INLET F5.1 (Storm F)4,953.11 HEC-22 Energy (Third Edition)0.28 4,951.76 4,951.47 4,952.20 4,951.91
SD AREA INLET F5.2 (Storm F)4,953.32 HEC-22 Energy (Third Edition)0.00 4,952.28 4,952.28 4,952.72 4,952.72
SD AREA INLET F7 (Storm F)4,953.05 HEC-22 Energy (Third Edition)0.29 4,951.98 4,951.69 4,952.42 4,952.13
SD AREA INLET F8 (Storm F)4,953.45 HEC-22 Energy (Third Edition)0.00 4,952.48 4,952.48 4,952.92 4,952.92
SD AREA INLET G1 (Storm G)4,944.60 HEC-22 Energy (Third Edition)0.10 4,946.58 4,946.47 4,947.10 4,947.00
SD AREA INLET G4 (Storm G)4,951.82 HEC-22 Energy (Third Edition)0.00 4,950.72 4,950.72 4,951.23 4,951.23
SD INLET E3.1 (Storm E)4,948.61 HEC-22 Energy (Third Edition)0.00 4,948.36 4,948.36 4,948.74 4,948.74
SD INLET E3.1A (Storm E)4,948.61 HEC-22 Energy (Third Edition)0.00 4,948.26 4,948.26 4,948.60 4,948.60
SD INLET E4.1-1 (Storm E)4,948.96 HEC-22 Energy (Third Edition)0.00 4,948.66 4,948.66 4,948.94 4,948.94
SD INLET E4.2 (Storm E)4,948.96 HEC-22 Energy (Third Edition)0.00 4,948.74 4,948.74 4,949.06 4,949.06
SD INLET F1 (Storm F)4,948.85 HEC-22 Energy (Third Edition)0.07 4,946.54 4,946.48 4,946.77 4,946.80
SD INLET F2.1 (Storm F)4,948.85 HEC-22 Energy (Third Edition)0.00 4,946.83 4,946.83 4,946.87 4,946.87
SD INLET H5.1 (Storm H)4,951.61 HEC-22 Energy (Third Edition)0.00 4,951.13 4,951.13 4,951.56 4,951.56
SD INLET H5.1A (Storm H)4,951.61 HEC-22 Energy (Third Edition)0.00 4,950.92 4,950.92 4,951.13 4,951.13
SD Inlet F3-B 4,949.30 HEC-22 Energy (Third Edition)0.00 4,948.44 4,948.44 4,948.47 4,948.47
SD Inlet Z2.1-A 4,947.98 HEC-22 Energy (Third Edition)0.00 4,947.69 4,947.69 4,947.70 4,947.70
SD Inlet Z2.2 4,948.02 HEC-22 Energy (Third Edition)0.00 4,947.86 4,947.86 4,948.07 4,948.07
SD Inlet Z3-A 4,947.92 HEC-22 Energy (Third Edition)0.00 4,947.85 4,947.85 4,948.35 4,948.35
SD Inlet Z3.1 4,947.84 HEC-22 Energy (Third Edition)0.00 4,947.82 4,947.82 4,948.04 4,948.04
SD Inlet Z6 4,952.36 HEC-22 Energy (Third Edition)0.00 4,948.88 4,948.88 4,948.98 4,948.98
SD OUTLET STRUCTURE A3 (Storm A)4,946.01 HEC-22 Energy (Third Edition)0.00 4,946.01 4,946.01 4,946.48 4,946.48
SD OUTLET STRUCTURE B3.1 (Storm B)4,942.72 HEC-22 Energy (Third Edition)0.00 4,942.72 4,942.72 4,942.90 4,942.90
SD OUTLET STRUCTURE B8 (Storm B)4,944.76 HEC-22 Energy (Third Edition)0.00 4,944.15 4,944.15 4,944.15 4,944.15
SDMH A1 (Storm A)4,951.55 HEC-22 Energy (Third Edition)0.09 4,945.12 4,945.03 4,945.58 4,945.49
SDMH A2 (Storm A)4,952.98 HEC-22 Energy (Third Edition)0.10 4,947.69 4,947.59 4,948.15 4,948.06
SDMH B1 (Storm B)4,943.51 HEC-22 Energy (Third Edition)0.32 4,942.87 4,942.55 4,943.21 4,942.91
SDMH B2 (Storm B)4,944.17 HEC-22 Energy (Third Edition)0.13 4,943.57 4,943.44 4,943.77 4,943.78
SDMH B3 (Storm B)4,944.38 HEC-22 Energy (Third Edition)0.12 4,944.13 4,944.01 4,944.13 4,944.20
SDMH B4 (Storm B)4,946.10 HEC-22 Energy (Third Edition)0.00 4,944.14 4,944.14 4,944.14 4,944.14
SDMH B5 (Storm B)4,949.18 HEC-22 Energy (Third Edition)0.00 4,944.14 4,944.14 4,944.14 4,944.14
SDMH B6 (Storm B)4,952.02 HEC-22 Energy (Third Edition)0.00 4,944.14 4,944.14 4,944.15 4,944.14
SDMH B7 (Storm B)4,952.60 HEC-22 Energy (Third Edition)0.00 4,944.15 4,944.15 4,944.15 4,944.15
SDMH E1 (Storm E)4,949.96 HEC-22 Energy (Third Edition)0.16 4,947.01 4,946.84 4,947.26 4,947.09
SDMH E2 (Storm E)4,949.19 HEC-22 Energy (Third Edition)0.09 4,947.30 4,947.21 4,947.77 4,947.46
SDMH E3 (Storm E)4,948.52 HEC-22 Energy (Third Edition)0.09 4,948.08 4,947.99 4,948.22 4,948.46
SDMH E4 (Storm E)4,951.75 HEC-22 Energy (Third Edition)0.03 4,948.35 4,948.33 4,948.49 4,948.46
SDMH E4.1 (Storm E)4,948.76 HEC-22 Energy (Third Edition)0.03 4,948.52 4,948.49 4,948.79 4,948.63
SDMH E5 (Storm E)4,948.45 HEC-22 Energy (Third Edition)0.06 4,947.17 4,947.11 4,947.47 4,947.39
SDMH E6 (Storm E)4,947.77 HEC-22 Energy (Third Edition)0.15 4,947.65 4,947.50 4,947.81 4,947.85
SDMH E7 (Storm E)4,953.23 HEC-22 Energy (Third Edition)0.10 4,948.44 4,948.34 4,948.61 4,948.49
SDMH E8 (Storm E)4,952.16 HEC-22 Energy (Third Edition)0.12 4,948.79 4,948.67 4,948.89 4,948.83
SDMH F2 (Storm F)4,948.67 HEC-22 Energy (Third Edition)0.14 4,946.78 4,946.65 4,946.83 4,946.88
SDMH F3 (Storm F)4,950.56 HEC-22 Energy (Third Edition)0.05 4,947.63 4,947.57 4,947.83 4,947.79
SDMH F4 (Storm F)4,952.29 HEC-22 Energy (Third Edition)0.13 4,948.47 4,948.34 4,948.60 4,948.72
SDMH F5 (Storm F)4,953.34 HEC-22 Energy (Third Edition)0.18 4,949.99 4,949.81 4,950.41 4,950.33
SDMH F6 (Storm F)4,953.44 HEC-22 Energy (Third Edition)0.28 4,950.56 4,950.28 4,951.00 4,950.70
SDMH G2 (Storm G)4,953.56 HEC-22 Energy (Third Edition)0.19 4,947.81 4,947.62 4,948.32 4,948.14
SDMH G3 (Storm G)4,953.59 HEC-22 Energy (Third Edition)0.18 4,950.11 4,949.93 4,950.62 4,950.44
SDMH H1 (Storm H)4,956.30 HEC-22 Energy (Third Edition)0.10 4,947.18 4,947.08 4,947.72 4,947.60
SDMH H2 (Storm H)4,955.20 HEC-22 Energy (Third Edition)0.35 4,948.50 4,948.15 4,949.05 4,948.68
SDMH H3 (Storm H)4,952.64 HEC-22 Energy (Third Edition)0.11 4,949.53 4,949.42 4,950.08 4,949.97
SDMH H4 (Storm H)4,952.06 HEC-22 Energy (Third Edition)0.11 4,950.01 4,949.90 4,950.58 4,950.45
Page 1 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/2103v3wa.xml
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm D_Eastern Pipes.stsw
SDMH H5 (Storm H)4,951.43 HEC-22 Energy (Third Edition)0.11 4,950.81 4,950.70 4,951.02 4,951.27
SDMH H6 (Storm H)4,951.56 HEC-22 Energy (Third Edition)0.06 4,951.16 4,951.10 4,951.46 4,951.39
SDMH H7 (Storm H)4,951.89 HEC-22 Energy (Third Edition)0.06 4,951.67 4,951.61 4,951.98 4,951.91
SDMH H8 (Storm H)4,952.23 HEC-22 Energy (Third Edition)0.06 4,952.15 4,952.09 4,952.47 4,952.39
SDMH Z2.1 4,948.14 HEC-22 Energy (Third Edition)0.06 4,947.68 4,947.62 4,947.69 4,947.92
Page 2 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/2103v3wa.xml
Scenario: 100 Year
P-97(StormK)P-187(2)(StormK)P-166(StormK)P-96(StormK)P-147(StormK)54.0in36.0in36.0in54.0in36.0inPage 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-16667/12/2022
Bentley StormCAD V8i (SELECTseries 4)
[08.11.04.54]Bentley Systems, Inc. Haestad Methods Solution CenterHFH022_Storm South Storm.stsw
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-39 4,938.12 HEC-22 Energy (Third Edition)0.00 4,938.03 4,938.03 4,938.22 4,938.22
MH-40 4,937.26 HEC-22 Energy (Third Edition)0.00 4,937.26 4,937.26 4,938.38 4,938.38
MH-41 4,938.75 HEC-22 Energy (Third Edition)0.00 4,936.09 4,936.09 4,936.16 4,936.16
MH-42 4,937.20 HEC-22 Energy (Third Edition)0.00 4,931.33 4,931.33 4,931.63 4,931.63
MH-43 4,935.42 HEC-22 Energy (Third Edition)0.00 4,931.27 4,931.27 4,931.38 4,931.38
MH-45 4,936.97 HEC-22 Energy (Third Edition)0.15 4,935.73 4,935.58 4,936.46 4,936.31
MH-46 4,933.00 HEC-22 Energy (Third Edition)0.00 4,933.00 4,933.00 4,933.73 4,933.73
SD INLET C2.1A (Storm C)4,938.75 HEC-22 Energy (Third Edition)0.00 4,936.04 4,936.04 4,936.11 4,936.11
SD INLET C3.1 (Storm C)4,940.53 HEC-22 Energy (Third Edition)0.00 4,936.32 4,936.32 4,936.33 4,936.33
SD INLET C3.1A (Storm C)4,940.53 HEC-22 Energy (Third Edition)0.00 4,936.32 4,936.32 4,936.32 4,936.32
SD INLET K1 (Storm K)4,936.80 HEC-22 Energy (Third Edition)0.56 4,935.89 4,935.33 4,936.42 4,936.00
SD INLET K2.1 (Storm K)4,936.80 HEC-22 Energy (Third Edition)0.00 4,936.49 4,936.49 4,936.51 4,936.51
SD INLET L1 (Storm L)4,936.17 HEC-22 Energy (Third Edition)0.01 4,935.26 4,935.24 4,935.50 4,935.30
SD INLET L2 (Storm L)4,936.17 HEC-22 Energy (Third Edition)0.00 4,935.60 4,935.60 4,935.84 4,935.84
SD INLET M-A2 (Storm M)4,929.98 HEC-22 Energy (Third Edition)0.00 4,929.98 4,929.98 4,930.50 4,930.50
SD INLET M4 (Storm M)4,935.42 HEC-22 Energy (Third Edition)0.33 4,929.93 4,929.60 4,930.66 4,929.94
SD INLET M8 (Storm M)4,937.20 HEC-22 Energy (Third Edition)0.07 4,930.85 4,930.77 4,930.94 4,931.14
SD OUTLET STRUCTURE C5 (Storm C)4,940.72 HEC-22 Energy (Third Edition)0.00 4,940.72 4,940.72 4,941.34 4,941.34
SD OUTLET STRUCTURE M1.1 (Storm M)4,926.72 HEC-22 Energy (Third Edition)0.00 4,926.72 4,926.72 4,926.74 4,926.74
SDMH C1 (Storm C)4,937.28 HEC-22 Energy (Third Edition)0.13 4,935.42 4,935.29 4,935.58 4,935.44
SDMH C2 (Storm C)4,938.52 HEC-22 Energy (Third Edition)0.07 4,936.01 4,935.94 4,936.08 4,936.11
SDMH C3 (Storm C)4,940.27 HEC-22 Energy (Third Edition)0.04 4,936.32 4,936.28 4,936.32 4,936.37
SDMH C4 (Storm C)4,945.68 HEC-22 Energy (Third Edition)0.29 4,941.56 4,941.27 4,942.18 4,941.89
SDMH K2 (Storm K)4,936.87 HEC-22 Energy (Third Edition)0.30 4,936.49 4,936.19 4,936.50 4,936.71
SDMH K3 (Storm K)4,937.76 HEC-22 Energy (Third Edition)0.09 4,937.11 4,937.01 4,937.55 4,937.46
SDMH K4 (Storm K)4,938.70 HEC-22 Energy (Third Edition)0.29 4,937.91 4,937.62 4,938.01 4,938.07
SDMH K5 (Storm K)4,937.96 HEC-22 Energy (Third Edition)0.00 4,937.96 4,937.96 4,938.15 4,938.06
SDMH M-A1 (Storm M)4,931.90 HEC-22 Energy (Third Edition)0.28 4,929.02 4,928.74 4,929.53 4,929.25
SDMH M1 (Storm M)4,932.51 HEC-22 Energy (Third Edition)0.07 4,927.85 4,927.78 4,927.87 4,928.08
SDMH M2 (Storm M)4,932.66 HEC-22 Energy (Third Edition)0.06 4,928.22 4,928.16 4,928.50 4,928.43
SDMH M3 (Storm M)4,933.09 HEC-22 Energy (Third Edition)0.07 4,929.16 4,929.09 4,929.45 4,929.39
SDMH M5 (Storm M)4,936.30 HEC-22 Energy (Third Edition)0.16 4,932.12 4,931.97 4,932.85 4,932.69
SDMH M6 (Storm M)4,937.38 HEC-22 Energy (Third Edition)0.15 4,934.21 4,934.07 4,934.94 4,934.80
SDMH M7 (Storm M)4,936.98 HEC-22 Energy (Third Edition)0.08 4,930.98 4,930.90 4,931.23 4,930.99
Page 1 of 1
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/nu1tqmzr.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-1 4,948.00 HEC-22 Energy (Third Edition)0.00 4,948.00 4,948.00 4,948.08 4,948.08
MH-2 4,947.00 HEC-22 Energy (Third Edition)0.00 4,947.00 4,947.00 4,947.08 4,947.08
MH-3 4,947.00 HEC-22 Energy (Third Edition)0.00 4,947.00 4,947.00 4,947.24 4,947.24
MH-4 4,946.00 HEC-22 Energy (Third Edition)0.00 4,946.00 4,946.00 4,946.43 4,946.43
MH-5 4,945.00 HEC-22 Energy (Third Edition)0.00 4,945.00 4,945.00 4,945.13 4,945.13
MH-6 4,948.00 HEC-22 Energy (Third Edition)0.00 4,945.82 4,945.82 4,945.98 4,945.98
MH-8 4,946.51 HEC-22 Energy (Third Edition)0.00 4,945.35 4,945.35 4,945.45 4,945.45
MH-11 4,946.00 HEC-22 Energy (Third Edition)0.00 4,945.23 4,945.23 4,945.33 4,945.33
MH-20 4,945.56 HEC-22 Energy (Third Edition)0.00 4,944.82 4,944.82 4,944.98 4,944.98
MH-24 4,946.28 HEC-22 Energy (Third Edition)0.02 4,945.85 4,945.83 4,945.88 4,945.92
MH-25 4,946.49 HEC-22 Energy (Third Edition)0.00 4,945.87 4,945.87 4,945.91 4,945.91
MH-26 4,946.49 HEC-22 Energy (Third Edition)0.00 4,945.92 4,945.92 4,946.03 4,946.03
MH-27 4,945.76 HEC-22 Energy (Third Edition)0.06 4,944.99 4,944.93 4,945.00 4,945.23
MH-28 4,945.85 HEC-22 Energy (Third Edition)0.05 4,945.63 4,945.58 4,945.69 4,945.81
MH-29 4,946.49 HEC-22 Energy (Third Edition)0.00 4,945.70 4,945.70 4,945.76 4,945.76
MH-30 4,946.49 HEC-22 Energy (Third Edition)0.00 4,945.68 4,945.68 4,945.77 4,945.77
MH-31 4,945.93 HEC-22 Energy (Third Edition)0.00 4,945.01 4,945.01 4,945.04 4,945.04
MH-32 4,945.93 HEC-22 Energy (Third Edition)0.00 4,945.00 4,945.00 4,945.01 4,945.01
MH-33 4,946.64 HEC-22 Energy (Third Edition)0.10 4,945.44 4,945.34 4,945.63 4,945.84
MH-35 4,946.21 HEC-22 Energy (Third Edition)0.00 4,945.68 4,945.68 4,946.10 4,946.10
SD AREA INLET I5-A.1 (Storm I)4,947.29 HEC-22 Energy (Third Edition)0.04 4,946.67 4,946.63 4,946.80 4,946.82
SD AREA INLET I5-A.1-A (Storm I)4,947.01 HEC-22 Energy (Third Edition)0.00 4,946.79 4,946.79 4,946.93 4,946.93
SD AREA INLET I5-A.2 (Storm I)4,947.92 HEC-22 Energy (Third Edition)0.11 4,947.33 4,947.22 4,947.47 4,947.35
SD AREA INLET I5-A.3 (Storm I)4,947.66 HEC-22 Energy (Third Edition)0.00 4,947.45 4,947.45 4,947.59 4,947.59
SD AREA INLET I5.1 (Storm I)4,947.00 HEC-22 Energy (Third Edition)0.05 4,946.47 4,946.42 4,946.60 4,946.48
SD AREA INLET I5.2 (Storm I)4,946.88 HEC-22 Energy (Third Edition)0.00 4,946.59 4,946.59 4,946.73 4,946.73
SD AREA INLET I6-A.1 (Storm I)4,947.56 HEC-22 Energy (Third Edition)0.11 4,947.18 4,947.06 4,947.61 4,947.20
SD AREA INLET I6-A.2 (Storm I)4,947.91 HEC-22 Energy (Third Edition)0.00 4,947.66 4,947.66 4,948.09 4,948.09
SD AREA INLET I6.1 (Storm I)4,948.28 HEC-22 Energy (Third Edition)0.25 4,948.00 4,947.75 4,948.14 4,948.21
SD AREA INLET I6.1-A (Storm I)4,948.84 HEC-22 Energy (Third Edition)0.00 4,948.50 4,948.50 4,948.94 4,948.94
SD AREA INLET I6.2 (Storm I)4,949.07 HEC-22 Energy (Third Edition)0.11 4,948.69 4,948.57 4,949.13 4,948.71
SD AREA INLET I6.3 (Storm I)4,949.76 HEC-22 Energy (Third Edition)0.00 4,949.19 4,949.19 4,949.63 4,949.63
SD INLET D1 4,945.86 HEC-22 Energy (Third Edition)0.04 4,944.33 4,944.29 4,944.54 4,944.49
SD INLET D2 4,945.86 HEC-22 Energy (Third Edition)0.00 4,944.61 4,944.61 4,944.82 4,944.82
SD INLET I2.1 (Storm I)4,946.38 HEC-22 Energy (Third Edition)0.00 4,945.62 4,945.62 4,945.81 4,945.81
SD INLET I4.1-A (Storm I)4,945.81 HEC-22 Energy (Third Edition)0.00 4,945.46 4,945.46 4,945.49 4,945.49
SD INLET I4.1-A.1 (Storm I)4,945.81 HEC-22 Energy (Third Edition)0.00 4,945.46 4,945.46 4,945.47 4,945.47
SD Inlet J1 4,945.36 HEC-22 Energy (Third Edition)0.03 4,944.22 4,944.19 4,944.32 4,944.35
SD Inlet J2.1 4,945.36 HEC-22 Energy (Third Edition)0.00 4,944.34 4,944.34 4,944.34 4,944.34
SD Inlet J4.1 4,945.04 HEC-22 Energy (Third Edition)0.00 4,944.75 4,944.75 4,944.76 4,944.76
SD Inlet J4.2 4,945.07 HEC-22 Energy (Third Edition)0.00 4,944.81 4,944.81 4,944.87 4,944.87
SD Inlet J5-A 4,945.42 HEC-22 Energy (Third Edition)0.00 4,944.91 4,944.91 4,944.99 4,944.99
SD Inlet J5.1 4,945.42 HEC-22 Energy (Third Edition)0.00 4,944.92 4,944.92 4,945.00 4,945.00
SDMH I2 (Storm I)4,947.01 HEC-22 Energy (Third Edition)0.06 4,944.26 4,944.20 4,944.53 4,944.48
SDMH I2-A.1 (Storm I)4,946.69 HEC-22 Energy (Third Edition)0.29 4,944.93 4,944.64 4,945.43 4,945.14
SDMH I2-A.2 (Storm I)4,946.46 HEC-22 Energy (Third Edition)0.17 4,946.18 4,946.01 4,946.32 4,946.50
SDMH I2-A.3 (Storm I)4,946.72 HEC-22 Energy (Third Edition)0.11 4,946.51 4,946.40 4,946.80 4,946.69
SDMH I2-A.4 (Storm I)4,947.44 HEC-22 Energy (Third Edition)0.11 4,947.11 4,947.00 4,947.36 4,947.28
SDMH I2-A.5 (Storm I)4,947.84 HEC-22 Energy (Third Edition)0.23 4,947.84 4,947.62 4,947.92 4,947.93
SDMH I2-A.6 (Storm I)4,948.96 HEC-22 Energy (Third Edition)0.06 4,948.04 4,947.97 4,948.11 4,948.05
SDMH I3 (Storm I)4,947.08 HEC-22 Energy (Third Edition)0.13 4,944.53 4,944.40 4,944.82 4,944.67
SDMH I4 (Storm I)4,946.20 HEC-22 Energy (Third Edition)0.19 4,945.38 4,945.20 4,945.45 4,945.47
SDMH I4.1 (Storm I)4,946.10 HEC-22 Energy (Third Edition)0.01 4,945.45 4,945.44 4,945.46 4,945.50
SDMH I4.2 (Storm I)4,946.81 HEC-22 Energy (Third Edition)0.07 4,945.71 4,945.63 4,945.79 4,945.72
SDMH I5 (Storm I)4,946.55 HEC-22 Energy (Third Edition)0.23 4,946.30 4,946.08 4,946.36 4,946.48
SDMH I6 (Storm I)4,947.16 HEC-22 Energy (Third Edition)0.17 4,946.69 4,946.52 4,946.82 4,946.72
SDMH J2 4,945.50 HEC-22 Energy (Third Edition)0.06 4,944.34 4,944.28 4,944.34 4,944.38
SDMH J3 4,946.84 HEC-22 Energy (Third Edition)0.02 4,944.60 4,944.58 4,944.67 4,944.68
SDMH J4 4,945.86 HEC-22 Energy (Third Edition)0.01 4,944.73 4,944.72 4,944.74 4,944.79
SDMH J4.1 4,945.10 HEC-22 Energy (Third Edition)0.00 4,944.74 4,944.74 4,944.75 4,944.75
Page 1 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/x1dmznuc.xml
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm E_Split.stsw
SDMH J5 4,945.56 HEC-22 Energy (Third Edition)0.03 4,944.84 4,944.81 4,944.93 4,944.90
SDMH J6 4,945.90 HEC-22 Energy (Third Edition)0.05 4,945.10 4,945.06 4,945.14 4,945.19
SDMH J7 4,946.58 HEC-22 Energy (Third Edition)0.02 4,945.26 4,945.24 4,945.36 4,945.27
Page 2 of 2
6/1/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/x1dmznuc.xml
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-39 4,938.12 HEC-22 Energy (Third Edition)0.00 4,933.70 4,933.70 4,933.76 4,933.76
MH-40 4,937.26 HEC-22 Energy (Third Edition)0.00 4,937.26 4,937.26 4,937.38 4,937.38
MH-41 4,938.75 HEC-22 Energy (Third Edition)0.00 4,934.09 4,934.09 4,934.21 4,934.21
MH-42 4,937.20 HEC-22 Energy (Third Edition)0.00 4,931.64 4,931.64 4,931.64 4,931.64
MH-43 4,935.42 HEC-22 Energy (Third Edition)0.00 4,930.21 4,930.21 4,930.35 4,930.35
MH-47 4,943.36 HEC-22 Energy (Third Edition)0.32 4,939.12 4,938.79 4,939.32 4,939.14
SD INLET C2.1A (Storm C)4,938.75 HEC-22 Energy (Third Edition)0.00 4,933.78 4,933.78 4,933.82 4,933.82
SD INLET C3.1 (Storm C)4,940.53 HEC-22 Energy (Third Edition)0.00 4,935.07 4,935.07 4,935.07 4,935.07
SD INLET C3.1A (Storm C)4,940.53 HEC-22 Energy (Third Edition)0.00 4,935.07 4,935.07 4,935.07 4,935.07
SD INLET K1 (Storm K)4,936.80 HEC-22 Energy (Third Edition)0.47 4,933.03 4,932.57 4,933.21 4,932.97
SD INLET K2.1 (Storm K)4,936.80 HEC-22 Energy (Third Edition)0.00 4,933.39 4,933.39 4,933.53 4,933.53
SD INLET L1 (Storm L)4,936.17 HEC-22 Energy (Third Edition)0.14 4,932.84 4,932.70 4,932.91 4,932.86
SD INLET L2 (Storm L)4,936.17 HEC-22 Energy (Third Edition)0.00 4,932.95 4,932.95 4,933.10 4,933.10
SD INLET M-A2 (Storm M)4,929.98 HEC-22 Energy (Third Edition)0.00 4,925.57 4,925.57 4,925.57 4,925.57
SD INLET M4 (Storm M)4,935.42 HEC-22 Energy (Third Edition)0.62 4,928.15 4,927.53 4,928.29 4,927.97
SD INLET M8 (Storm M)4,937.20 HEC-22 Energy (Third Edition)0.04 4,931.76 4,931.72 4,931.92 4,931.91
SD OUTLET STRUCTURE C5 (Storm C)4,940.72 HEC-22 Energy (Third Edition)0.00 4,940.72 4,940.72 4,940.77 4,940.77
SD OUTLET STRUCTURE M1.1 (Storm M)4,926.72 HEC-22 Energy (Third Edition)0.00 4,925.09 4,925.09 4,925.09 4,925.09
SD Outlet Structure O1 4,930.72 HEC-22 Energy (Third Edition)0.00 4,930.72 4,930.72 4,930.88 4,930.88
SDMH C1 (Storm C)4,937.28 HEC-22 Energy (Third Edition)1.29 4,932.11 4,930.82 4,932.17 4,931.18
SDMH C2 (Storm C)4,938.52 HEC-22 Energy (Third Edition)0.48 4,933.57 4,933.09 4,933.66 4,933.46
SDMH C3 (Storm C)4,940.27 HEC-22 Energy (Third Edition)0.26 4,935.07 4,934.80 4,935.07 4,935.14
SDMH C4 (Storm C)4,945.68 HEC-22 Energy (Third Edition)1.04 4,941.00 4,939.96 4,941.03 4,940.28
SDMH K2 (Storm K)4,936.87 HEC-22 Energy (Third Edition)0.11 4,933.24 4,933.13 4,933.32 4,933.31
SDMH K3 (Storm K)4,937.76 HEC-22 Energy (Third Edition)0.02 4,933.33 4,933.30 4,933.43 4,933.42
SDMH K4 (Storm K)4,938.70 HEC-22 Energy (Third Edition)0.15 4,933.57 4,933.42 4,933.58 4,933.58
SDMH K5 (Storm K)4,937.96 HEC-22 Energy (Third Edition)0.04 4,933.67 4,933.63 4,933.71 4,933.68
SDMH M-A1 (Storm M)4,931.90 HEC-22 Energy (Third Edition)0.00 4,924.68 4,924.68 4,924.68 4,924.68
SDMH M1 (Storm M)4,932.51 HEC-22 Energy (Third Edition)0.42 4,925.09 4,924.67 4,925.09 4,925.10
SDMH M2 (Storm M)4,932.66 HEC-22 Energy (Third Edition)0.37 4,925.55 4,925.18 4,925.71 4,925.53
SDMH M3 (Storm M)4,933.09 HEC-22 Energy (Third Edition)0.50 4,927.19 4,926.70 4,927.35 4,927.13
SDMH M5 (Storm M)4,936.30 HEC-22 Energy (Third Edition)0.46 4,928.82 4,928.35 4,928.98 4,928.73
SDMH M6 (Storm M)4,937.38 HEC-22 Energy (Third Edition)0.46 4,929.52 4,929.06 4,929.69 4,929.46
SDMH M7 (Storm M)4,936.98 HEC-22 Energy (Third Edition)1.71 4,931.63 4,929.92 4,931.64 4,930.37
Page 1 of 1
7/12/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/3tmzblbr.xml
Scenario: 2 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
CO-48 SDMH C4 (Storm C)MH-47 4,939.00 4,938.07 242.8 0.004 30.0 0.013 7.93 4.57 25.38 4,939.96 4,939.22 4,940.28 4,939.42 0.74
CO-45 SD OUTLET STRUCTURE C5 (Storm C)CB-1 4,939.50 4,939.03 68.3 0.007 18.0 0.013 3.21 1.82 8.71 4,941.08 4,941.02 4,941.13 4,941.07 0.06
P-71 (Storm C)SD INLET C3.1 (Storm C)SDMH C3 (Storm C)4,933.79 4,933.56 47.0 0.005 36.0 0.013 0.70 2.42 47.16 4,935.07 4,935.07 4,935.07 4,935.07 0.00
P-107 (Storm C)SDMH C3 (Storm C)SD INLET C3.1A (Storm C)4,933.59 4,933.56 6.0 0.005 36.0 0.013 0.65 0.09 47.16 4,935.07 4,935.07 4,935.07 4,935.07 0.00
P-70 (Storm C)SDMH C3 (Storm C)SDMH C2 (Storm C)4,933.87 4,932.09 356.0 0.005 36.0 0.013 8.76 5.10 47.16 4,934.80 4,933.61 4,935.14 4,933.70 1.19
P-105 (Storm C)SDMH C2 (Storm C)SD INLET C2.1A (Storm C)4,933.34 4,933.28 6.0 0.010 18.0 0.013 0.86 0.48 10.50 4,933.78 4,933.72 4,933.82 4,933.81 0.06
P-69 (Storm C)SDMH C2 (Storm C)SDMH C1 (Storm C)4,932.09 4,930.15 388.1 0.005 36.0 0.013 10.05 5.30 47.16 4,933.09 4,932.14 4,933.46 4,932.20 0.96
P-68 (Storm C)SDMH C1 (Storm C)STORM FES C (Storm C)4,929.84 4,929.39 63.5 0.007 36.0 0.013 9.73 5.96 56.17 4,930.82 4,930.23 4,931.18 4,930.78 0.59
P-99 (Storm K)SDMH K4 (Storm K)SDMH K3 (Storm K)4,931.68 4,931.31 180.9 0.002 -0.013 25.00 4.57 86.98 4,933.42 4,933.37 4,933.58 4,933.48 0.04
P-187 (1) (Storm K)SDMH K5 (Storm K)SDMH K4 (Storm K)4,932.43 4,931.68 377.1 0.002 36.0 0.013 5.00 3.13 29.74 4,933.63 4,933.57 4,933.68 4,933.59 0.05
P-98 (Storm K)SDMH K3 (Storm K)SDMH K2 (Storm K)4,931.31 4,930.94 186.6 0.002 -0.013 25.00 4.52 85.65 4,933.30 4,933.27 4,933.42 4,933.35 0.03
P-97 (Storm K)SDMH K2 (Storm K)SD INLET K1 (Storm K)4,930.94 4,930.86 38.4 0.002 54.0 0.013 26.67 4.92 89.80 4,933.13 4,933.11 4,933.31 4,933.29 0.02
P-147 (Storm K)SD INLET K2.1 (Storm K)SDMH K2 (Storm K)4,932.99 4,932.91 16.6 0.005 36.0 0.013 1.67 3.16 47.66 4,933.39 4,933.33 4,933.53 4,933.45 0.06
P-96 (Storm K)SD INLET K1 (Storm K)FES K (Storm K)4,930.86 4,930.74 61.8 0.002 54.0 0.013 28.35 4.88 86.63 4,932.57 4,932.26 4,932.97 4,932.82 0.30
P-100 (Storm L)SD INLET L1 (Storm L)SD FES L (Storm L)4,932.23 4,932.01 55.3 0.004 -0.013 3.17 3.27 41.44 4,932.70 4,932.48 4,932.86 4,932.65 0.22
P-101 (Storm L)SD INLET L2 (Storm L)SD INLET L1 (Storm L)4,932.45 4,932.23 55.0 0.004 18.0 0.013 1.60 3.09 6.64 4,932.95 4,932.87 4,933.10 4,932.95 0.08
P-76 (Storm M)SDMH M6 (Storm M)SDMH M5 (Storm M)4,927.86 4,927.13 183.2 0.004 30.0 0.013 11.85 5.16 25.89 4,929.06 4,928.89 4,929.46 4,929.05 0.17
CO-50 SDMH M6 (Storm M)SDMH M7 (Storm M)4,927.86 4,928.76 --0.008 30.0 0.013 11.88 6.53 35.67 4,929.92 4,929.59 4,930.37 4,929.76 0.33
P-150 (Storm M)SD INLET M8 (Storm M)SDMH M7 (Storm M)4,928.34 4,928.36 6.0 -0.003 24.0 0.013 10.99 3.50 13.05 4,931.72 4,931.71 4,931.91 4,931.90 0.01
P-75 (Storm M)SDMH M5 (Storm M)SD INLET M4 (Storm M)4,927.13 4,926.36 193.1 0.004 30.0 0.013 11.80 5.16 25.90 4,928.35 4,928.21 4,928.73 4,928.35 0.14
P-102 (Storm M)SD INLET M4 (Storm M)SDMH M3 (Storm M)4,926.36 4,925.53 207.1 0.004 36.0 0.013 13.54 5.32 42.22 4,927.53 4,927.26 4,927.97 4,927.42 0.27
P-74 (Storm M)SDMH M3 (Storm M)SDMH M2 (Storm M)4,925.53 4,923.93 400.0 0.004 36.0 0.013 13.44 5.30 42.18 4,926.70 4,925.62 4,927.13 4,925.79 1.08
P-73 (Storm M)SDMH M2 (Storm M)SDMH M1 (Storm M)4,923.93 4,923.51 103.7 0.004 36.0 0.013 13.28 5.31 42.45 4,925.18 4,925.17 4,925.53 4,925.34 0.01
P-72 (Storm M)SDMH M1 (Storm M)O-6 4,923.51 4,923.00 125.7 0.004 36.0 0.013 13.23 5.31 42.49 4,924.67 4,924.21 4,925.10 4,924.59 0.46
CO-42 SDMH M-A1 (Storm M)O-7 4,924.68 4,924.40 133.4 0.002 48.0 0.013 0.00 0.00 196.23 4,924.68 4,924.40 4,924.68 4,924.40 0.28
P-186 (2) (Storm M)SD INLET M-A2 (Storm M)SDMH M-A1 (Storm M)4,925.57 4,924.68 444.2 0.002 48.0 0.013 0.00 0.00 192.71 4,925.57 4,924.68 4,925.57 4,924.68 0.89
P-148 (Storm M)SD OUTLET STRUCTURE M1.1 (Storm M)SDMH M1 (Storm M)4,923.66 4,923.51 30.1 0.005 18.0 0.013 0.00 0.00 7.41 4,925.09 4,925.09 4,925.09 4,925.09 0.00
P-187 (2) (Storm K)MH-39 SDMH K5 (Storm K)4,932.53 4,932.43 50.5 0.002 36.0 0.013 5.00 3.12 29.68 4,933.70 4,933.69 4,933.76 4,933.73 0.01
P-166 (Storm K)MH-40 SDMH K4 (Storm K)4,933.74 4,933.54 50.5 0.004 36.0 0.013 20.00 2.83 42.18 4,938.75 4,938.70 4,938.87 4,938.83 0.05
P-106 (Storm C)MH-41 SDMH C2 (Storm C)4,933.75 4,933.28 47.2 0.010 18.0 0.013 0.85 3.58 10.50 4,934.09 4,933.65 4,934.21 4,933.75 0.45
P-151 (Storm M)MH-42 SDMH M7 (Storm M)4,928.53 4,928.34 46.5 0.004 18.0 0.013 1.02 0.58 6.71 4,931.64 4,931.63 4,931.64 4,931.64 0.00
P-149 (Storm M)MH-43 SD INLET M4 (Storm M)4,929.82 4,929.56 52.5 0.005 18.0 0.013 1.09 3.01 7.43 4,930.21 4,929.95 4,930.35 4,930.09 0.26
CO-46 CB-1 SDMH C4 (Storm C)4,939.03 4,939.00 6.0 0.005 24.0 0.013 5.35 4.58 16.00 4,941.02 4,941.02 4,941.06 4,941.06 0.00
CO-47 CB-2 SDMH C4 (Storm C)4,939.49 4,939.00 47.0 0.010 18.0 0.013 2.70 1.53 10.72 4,941.04 4,941.01 4,941.08 4,941.05 0.03
CO-49 MH-47 SDMH C3 (Storm C)4,937.87 4,934.70 413.2 0.008 30.0 0.013 7.74 5.84 35.92 4,938.79 4,936.90 4,939.14 4,936.94 1.90
P-78 (Storm M)SD Outlet Structure O1 SD INLET M8 (Storm M)4,928.58 4,928.36 54.0 0.004 24.0 0.013 10.00 3.18 14.44 4,931.93 4,931.82 4,932.08 4,931.98 0.11
Page 1 of 1
7/12/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/lnbp1thi.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Manhole Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Elevation
(Rim) (ft)
Headloss
Method
Headloss
(ft)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
MH-39 4,938.12 HEC-22 Energy (Third Edition)0.00 4,937.85 4,937.85 4,937.92 4,937.92
MH-40 4,937.26 HEC-22 Energy (Third Edition)0.00 4,937.26 4,937.26 4,938.20 4,938.20
MH-41 4,938.75 HEC-22 Energy (Third Edition)0.00 4,937.02 4,937.02 4,937.09 4,937.09
MH-42 4,937.20 HEC-22 Energy (Third Edition)0.00 4,933.54 4,933.54 4,933.64 4,933.64
MH-43 4,935.42 HEC-22 Energy (Third Edition)0.00 4,930.70 4,930.70 4,931.01 4,931.01
MH-47 4,943.36 HEC-22 Energy (Third Edition)1.03 4,940.61 4,939.57 4,941.03 4,940.34
SD INLET C2.1A (Storm C)4,938.75 HEC-22 Energy (Third Edition)0.00 4,936.98 4,936.98 4,937.04 4,937.04
SD INLET C3.1 (Storm C)4,940.53 HEC-22 Energy (Third Edition)0.00 4,937.79 4,937.79 4,937.80 4,937.80
SD INLET C3.1A (Storm C)4,940.53 HEC-22 Energy (Third Edition)0.00 4,937.79 4,937.79 4,937.79 4,937.79
SD INLET K1 (Storm K)4,936.80 HEC-22 Energy (Third Edition)0.14 4,936.17 4,936.03 4,936.54 4,936.47
SD INLET K2.1 (Storm K)4,936.80 HEC-22 Energy (Third Edition)0.00 4,936.60 4,936.60 4,936.61 4,936.61
SD INLET L1 (Storm L)4,936.17 HEC-22 Energy (Third Edition)0.01 4,935.26 4,935.24 4,935.50 4,935.30
SD INLET L2 (Storm L)4,936.17 HEC-22 Energy (Third Edition)0.00 4,935.60 4,935.60 4,935.84 4,935.84
SD INLET M-A2 (Storm M)4,929.98 HEC-22 Energy (Third Edition)0.00 4,929.98 4,929.98 4,930.50 4,930.50
SD INLET M4 (Storm M)4,935.42 HEC-22 Energy (Third Edition)0.11 4,930.35 4,930.24 4,930.60 4,930.59
SD INLET M8 (Storm M)4,937.20 HEC-22 Energy (Third Edition)0.15 4,933.93 4,933.78 4,934.41 4,934.53
SD OUTLET STRUCTURE C5 (Storm C)4,940.72 HEC-22 Energy (Third Edition)0.00 4,940.72 4,940.72 4,941.11 4,941.11
SD OUTLET STRUCTURE M1.1 (Storm M)4,926.72 HEC-22 Energy (Third Edition)0.00 4,926.72 4,926.72 4,926.74 4,926.74
SD Outlet Structure O1 4,930.72 HEC-22 Energy (Third Edition)0.00 4,930.72 4,930.72 4,931.21 4,931.21
SDMH C1 (Storm C)4,937.28 HEC-22 Energy (Third Edition)0.29 4,935.66 4,935.37 4,936.02 4,935.71
SDMH C2 (Storm C)4,938.52 HEC-22 Energy (Third Edition)0.12 4,936.94 4,936.82 4,937.01 4,937.18
SDMH C3 (Storm C)4,940.27 HEC-22 Energy (Third Edition)0.09 4,937.79 4,937.70 4,937.79 4,937.96
SDMH C4 (Storm C)4,945.68 HEC-22 Energy (Third Edition)0.28 4,942.00 4,941.72 4,942.42 4,942.15
SDMH K2 (Storm K)4,936.87 HEC-22 Energy (Third Edition)0.21 4,936.59 4,936.38 4,936.60 4,936.74
SDMH K3 (Storm K)4,937.76 HEC-22 Energy (Third Edition)0.06 4,937.02 4,936.96 4,937.32 4,937.26
SDMH K4 (Storm K)4,938.70 HEC-22 Energy (Third Edition)0.16 4,937.54 4,937.38 4,937.61 4,937.68
SDMH K5 (Storm K)4,937.96 HEC-22 Energy (Third Edition)0.05 4,937.80 4,937.75 4,937.87 4,937.82
SDMH M-A1 (Storm M)4,931.90 HEC-22 Energy (Third Edition)0.28 4,929.02 4,928.74 4,929.53 4,929.25
SDMH M1 (Storm M)4,932.51 HEC-22 Energy (Third Edition)0.09 4,927.91 4,927.83 4,927.93 4,928.19
SDMH M2 (Storm M)4,932.66 HEC-22 Energy (Third Edition)0.07 4,928.36 4,928.29 4,928.70 4,928.61
SDMH M3 (Storm M)4,933.09 HEC-22 Energy (Third Edition)0.08 4,929.57 4,929.49 4,929.92 4,929.83
SDMH M5 (Storm M)4,936.30 HEC-22 Energy (Third Edition)0.09 4,931.38 4,931.29 4,931.82 4,931.72
SDMH M6 (Storm M)4,937.38 HEC-22 Energy (Third Edition)0.09 4,932.38 4,932.29 4,932.82 4,932.73
SDMH M7 (Storm M)4,936.98 HEC-22 Energy (Third Edition)0.37 4,933.42 4,933.04 4,933.51 4,933.49
Page 1 of 1
7/12/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/svymxc1w.xml
Scenario: 100 Year
Current Time Step: 0.000Hr
FlexTable: GAL Conduit Table
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain Reports\Prop\Hydraulics\FDP_F1\StormCAD\HFH022_Storm South Storm.stsw
Label Start Node Stop Node
Invert
(Start)
(ft)
Invert
(Stop)
(ft)
Length
(User
Defined)
(ft)
Slope
(Calculated)
(ft/ft)
Diameter
(in)
Manning's
n
Flow
(cfs)
Velocity
(ft/s)
Capacity
(Full
Flow)
(cfs)
Hydraulic
Grade
Line (In)
(ft)
Hydraulic
Grade
Line
(Out) (ft)
Energy
Grade
Line (In)
(ft)
Energy
Grade
Line
(Out) (ft)
Headloss
(ft)
CO-48 SDMH C4 (Storm C)MH-47 4,939.00 4,938.07 242.8 0.004 30.0 0.013 25.60 5.22 25.38 4,941.72 4,940.78 4,942.15 4,941.20 0.95
CO-45 SD OUTLET STRUCTURE C5 (Storm C)CB-1 4,939.50 4,939.03 68.3 0.007 18.0 0.013 8.85 5.01 8.71 4,942.69 4,942.20 4,943.08 4,942.59 0.48
P-71 (Storm C)SD INLET C3.1 (Storm C)SDMH C3 (Storm C)4,933.79 4,933.56 47.0 0.005 36.0 0.013 3.06 0.43 47.16 4,937.79 4,937.79 4,937.80 4,937.79 0.00
P-107 (Storm C)SDMH C3 (Storm C)SD INLET C3.1A (Storm C)4,933.59 4,933.56 6.0 0.005 36.0 0.013 2.81 0.40 47.16 4,937.79 4,937.79 4,937.79 4,937.79 0.00
P-70 (Storm C)SDMH C3 (Storm C)SDMH C2 (Storm C)4,933.87 4,932.09 356.0 0.005 36.0 0.013 28.72 4.06 47.16 4,937.70 4,937.04 4,937.96 4,937.30 0.66
P-105 (Storm C)SDMH C2 (Storm C)SD INLET C2.1A (Storm C)4,933.34 4,933.28 6.0 0.010 18.0 0.013 3.73 2.11 10.50 4,936.98 4,936.97 4,937.04 4,937.04 0.01
P-69 (Storm C)SDMH C2 (Storm C)SDMH C1 (Storm C)4,932.09 4,930.15 388.1 0.005 36.0 0.013 34.05 4.82 47.16 4,936.82 4,935.81 4,937.18 4,936.17 1.01
P-68 (Storm C)SDMH C1 (Storm C)STORM FES C (Storm C)4,929.84 4,929.39 63.5 0.007 36.0 0.013 32.84 4.65 56.17 4,935.37 4,935.22 4,935.71 4,935.56 0.15
P-99 (Storm K)SDMH K4 (Storm K)SDMH K3 (Storm K)4,931.68 4,931.31 180.9 0.002 -0.013 70.00 4.06 86.98 4,937.38 4,937.14 4,937.68 4,937.44 0.24
P-187 (1) (Storm K)SDMH K5 (Storm K)SDMH K4 (Storm K)4,932.43 4,931.68 377.1 0.002 36.0 0.013 15.00 2.12 29.74 4,937.75 4,937.56 4,937.82 4,937.63 0.19
P-98 (Storm K)SDMH K3 (Storm K)SDMH K2 (Storm K)4,931.31 4,930.94 186.6 0.002 -0.013 70.00 4.06 85.65 4,936.96 4,936.71 4,937.26 4,937.01 0.25
P-97 (Storm K)SDMH K2 (Storm K)SD INLET K1 (Storm K)4,930.94 4,930.86 38.4 0.002 54.0 0.013 77.13 4.85 89.80 4,936.38 4,936.32 4,936.74 4,936.68 0.06
P-147 (Storm K)SD INLET K2.1 (Storm K)SDMH K2 (Storm K)4,932.99 4,932.91 16.6 0.005 36.0 0.013 7.19 1.02 47.66 4,936.60 4,936.59 4,936.61 4,936.61 0.00
P-96 (Storm K)SD INLET K1 (Storm K)FES K (Storm K)4,930.86 4,930.74 61.8 0.002 54.0 0.013 84.33 5.30 86.63 4,936.03 4,935.92 4,936.47 4,936.36 0.11
P-100 (Storm L)SD INLET L1 (Storm L)SD FES L (Storm L)4,932.23 4,932.01 55.3 0.004 -0.013 13.89 1.80 41.44 4,935.24 4,935.22 4,935.30 4,935.28 0.02
P-101 (Storm L)SD INLET L2 (Storm L)SD INLET L1 (Storm L)4,932.45 4,932.23 55.0 0.004 18.0 0.013 6.99 3.96 6.64 4,935.60 4,935.36 4,935.84 4,935.60 0.24
P-76 (Storm M)SDMH M6 (Storm M)SDMH M5 (Storm M)4,927.86 4,927.13 183.2 0.004 30.0 0.013 26.04 5.31 25.89 4,932.29 4,931.55 4,932.73 4,931.99 0.74
CO-50 SDMH M6 (Storm M)SDMH M7 (Storm M)4,927.86 4,928.76 --0.008 30.0 0.013 26.20 5.34 35.67 4,933.04 4,932.56 4,933.49 4,933.00 0.49
P-150 (Storm M)SD INLET M8 (Storm M)SDMH M7 (Storm M)4,928.34 4,928.36 6.0 -0.003 24.0 0.013 21.92 6.98 13.05 4,933.78 4,933.72 4,934.53 4,934.48 0.06
P-75 (Storm M)SDMH M5 (Storm M)SD INLET M4 (Storm M)4,927.13 4,926.36 193.1 0.004 30.0 0.013 25.81 5.26 25.90 4,931.29 4,930.52 4,931.72 4,930.95 0.76
P-102 (Storm M)SD INLET M4 (Storm M)SDMH M3 (Storm M)4,926.36 4,925.53 207.1 0.004 36.0 0.013 33.74 4.77 42.22 4,930.24 4,929.71 4,930.59 4,930.06 0.53
P-74 (Storm M)SDMH M3 (Storm M)SDMH M2 (Storm M)4,925.53 4,923.93 400.0 0.004 36.0 0.013 33.23 4.70 42.18 4,929.49 4,928.50 4,929.83 4,928.84 0.99
P-73 (Storm M)SDMH M2 (Storm M)SDMH M1 (Storm M)4,923.93 4,923.51 103.7 0.004 36.0 0.013 32.33 4.57 42.45 4,928.29 4,928.04 4,928.61 4,928.37 0.24
P-72 (Storm M)SDMH M1 (Storm M)O-6 4,923.51 4,923.00 125.7 0.004 36.0 0.013 34.11 4.83 42.49 4,927.83 4,927.50 4,928.19 4,927.86 0.33
CO-42 SDMH M-A1 (Storm M)O-7 4,924.68 4,924.40 133.4 0.002 48.0 0.013 217.00 5.76 196.23 4,928.74 4,928.40 4,929.25 4,928.92 0.34
P-186 (2) (Storm M)SD INLET M-A2 (Storm M)SDMH M-A1 (Storm M)4,925.57 4,924.68 444.2 0.002 48.0 0.013 217.00 5.76 192.71 4,930.35 4,929.22 4,930.86 4,929.74 1.13
P-148 (Storm M)SD OUTLET STRUCTURE M1.1 (Storm M)SDMH M1 (Storm M)4,923.66 4,923.51 30.1 0.005 18.0 0.013 2.00 1.13 7.41 4,927.93 4,927.92 4,927.95 4,927.94 0.01
P-187 (2) (Storm K)MH-39 SDMH K5 (Storm K)4,932.53 4,932.43 50.5 0.002 36.0 0.013 15.00 2.12 29.68 4,937.85 4,937.83 4,937.92 4,937.90 0.03
P-166 (Storm K)MH-40 SDMH K4 (Storm K)4,933.74 4,933.54 50.5 0.004 36.0 0.013 55.00 7.78 42.18 4,938.26 4,937.91 4,939.20 4,938.85 0.34
P-106 (Storm C)MH-41 SDMH C2 (Storm C)4,933.75 4,933.28 47.2 0.010 18.0 0.013 3.67 2.08 10.50 4,937.02 4,936.97 4,937.09 4,937.03 0.06
P-151 (Storm M)MH-42 SDMH M7 (Storm M)4,928.53 4,928.34 46.5 0.004 18.0 0.013 4.44 2.51 6.71 4,933.54 4,933.46 4,933.64 4,933.55 0.08
P-149 (Storm M)MH-43 SD INLET M4 (Storm M)4,929.82 4,929.56 52.5 0.005 18.0 0.013 4.75 4.46 7.43 4,930.70 4,930.51 4,931.01 4,930.76 0.19
CO-46 CB-1 SDMH C4 (Storm C)4,939.03 4,939.00 6.0 0.005 24.0 0.013 16.30 5.19 16.00 4,942.20 4,942.17 4,942.62 4,942.59 0.03
CO-47 CB-2 SDMH C4 (Storm C)4,939.49 4,939.00 47.0 0.010 18.0 0.013 9.42 5.33 10.72 4,942.56 4,942.18 4,943.00 4,942.62 0.38
CO-49 MH-47 SDMH C3 (Storm C)4,937.87 4,934.70 413.2 0.008 30.0 0.013 24.99 7.55 35.92 4,939.57 4,937.95 4,940.34 4,938.35 1.62
P-78 (Storm M)SD Outlet Structure O1 SD INLET M8 (Storm M)4,928.58 4,928.36 54.0 0.004 24.0 0.013 17.60 5.60 14.44 4,934.45 4,934.12 4,934.94 4,934.61 0.33
Page 1 of 1
7/12/2022file:///C:/Users/Matthew_pepin/AppData/Local/Temp/Bentley/StormCAD/f1w1qlv3.xml
Bloom Filing 1
Final Drainage Report
Detention
Stormwater Facility Name:
Facility Location & Jurisdiction:
User Input: Watershed Characteristics User Defined User Defined User Defined User Defined
Selected BMP Type =EDB Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs]
Watershed Area =37.17 acres 0.00 0 0.00 0.00
Watershed Length =1,750 ft 0.50 66,092 0.50 0.70
Watershed Length to Centroid =850 ft 1.00 69,992 1.00 0.71
Watershed Slope =0.010 ft/ft 2.00 79,798 2.00 0.72
Watershed Imperviousness =48.0%percent 3.00 87,017 3.00 0.73
Percentage Hydrologic Soil Group A =0.0%percent 4.00 94,197 4.00 0.74
Percentage Hydrologic Soil Group B =50.0%percent 5.00 102,909 5.00 0.75
Percentage Hydrologic Soil Groups C/D =50.0%percent
Target WQCV Drain Time =40.0 hours
User Input
After completing and printing this worksheet to a pdf, go to:
https://maperture.digitaldataservices.com/gvh/?viewer=cswdif
Create a new stormwater facility, and attach the PDF of this
worksheet to that record.
Routed Hydrograph Results
Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year
One-Hour Rainfall Depth =N/A 0.82 1.14 1.40 2.35 2.86 in
CUHP Runoff Volume =0.622 1.075 1.715 2.395 5.505 7.279 acre-ft
Inflow Hydrograph Volume =N/A 1.075 1.715 2.395 5.505 7.279 acre-ft
Time to Drain 97% of Inflow Volume =14.4 21.7 31.5 42.1 91.0 118.8 hours
Time to Drain 99% of Inflow Volume =15.7 23.3 33.6 44.5 94.7 0.0 hours
Maximum Ponding Depth =0.66 0.87 1.26 1.65 3.28 4.12 ft
Maximum Ponded Area =1.55 1.58 1.66 1.75 2.04 2.18 acres
Maximum Volume Stored =0.624 0.944 1.573 2.243 5.349 7.115 acre-ft
Once CUHP has been run and the Stage-Area-Discharge
information has been provided, click 'Process Data' to
interpolate the Stage-Area-Volume-Discharge data and
generate summary results in the table below. Once this
is complete, click 'Print to PDF'.
Stormwater Detention and Infiltration Design Data Sheet
Pond D
Mulberry
SDI-Design Data v2.00, Released January 2020
Location for 1-hr Rainfall Depths (use dropdown):
After providing required inputs above including 1-hour
rainfall depths, click 'Run CUHP' to generate runoff
hydrographs using the embedded Colorado Urban
Hydrograph Procedure.
SDI_Design_Data_v2.00_Pond D.xlsm, Design Data 7/7/2022, 2:51 PM
Booleans for Message Booleans for CUHP
Watershed L:W 1 CUHP Inputs Complete
Watershed Lc:L 1 CUHP Results Calculated
Watershed Slope FALSE Time Interval
RunOnce 1
CountA 1
Draintime Coeff 1.0
User Precip 1
Equal SA Inputs 1
Equal SD Inputs 1
Stormwater Detention and Infiltration Design Data Sheet
0
20
40
60
80
100
120
0.1 1 10FLOW[cfs]TIME [hr]
100YR IN
100YR OUT
50YR IN
50YR OUT
10YR IN
10YR OUT
5YR IN
5YR OUT
2YR IN
2YR OUT
WQCV IN
WQCV OUT
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
0.1 1 10 100PONDINGDEPTH[ft]DRAIN TIME [hr]
100YR
50YR
10YR
5YR
2YR
WQCV
SDI_Design_Data_v2.00_Pond D.xlsm, Design Data 7/7/2022, 2:51 PM
Stormwater Facility Name:
Facility Location & Jurisdiction:
User Input: Watershed Characteristics User Defined User Defined User Defined User Defined
Selected BMP Type =EDB Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs]
Watershed Area =14.80 acres 0.00 0 0.00 0.00
Watershed Length =1,750 ft 0.50 77,785 0.50 0.20
Watershed Length to Centroid =850 ft 1.00 80,653 1.00 0.40
Watershed Slope =0.010 ft/ft 2.00 86,235 2.00 1.36
Watershed Imperviousness =66.0%percent 3.00 91,973 3.00 1.70
Percentage Hydrologic Soil Group A =0.0%percent 4.00 97,871 4.00 1.88
Percentage Hydrologic Soil Group B =50.0%percent 5.00 103,927 5.00 1.89
Percentage Hydrologic Soil Groups C/D =50.0%percent 6.00 110,139 6.00 1.90
Target WQCV Drain Time =40.0 hours 6.50 113,306 6.50 1.91
User Input
After completing and printing this worksheet to a pdf, go to:
https://maperture.digitaldataservices.com/gvh/?viewer=cswdif
Create a new stormwater facility, and attach the PDF of this
worksheet to that record.
Routed Hydrograph Results
Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year
One-Hour Rainfall Depth =N/A 0.82 1.14 1.40 2.35 2.86 in
CUHP Runoff Volume =0.318 0.618 0.937 1.237 2.492 3.193 acre-ft
Inflow Hydrograph Volume =N/A 0.618 0.937 1.237 2.492 3.193 acre-ft
Time to Drain 97% of Inflow Volume =37.9 53.5 65.3 73.9 92.6 97.1 hours
Time to Drain 99% of Inflow Volume =41.3 58.2 71.0 80.5 101.9 107.7 hours
Maximum Ponding Depth =0.43 0.57 0.74 0.90 1.53 1.87 ft
Maximum Ponded Area =1.51 1.79 1.82 1.84 1.92 1.96 acres
Maximum Volume Stored =0.323 0.570 0.880 1.164 2.352 3.008 acre-ft
Once CUHP has been run and the Stage-Area-Discharge
information has been provided, click 'Process Data' to
interpolate the Stage-Area-Volume-Discharge data and
generate summary results in the table below. Once this
is complete, click 'Print to PDF'.
Stormwater Detention and Infiltration Design Data Sheet
Pond D - WQCV Drain Time Only
Mulberry
SDI-Design Data v2.00, Released January 2020
Location for 1-hr Rainfall Depths (use dropdown):
After providing required inputs above including 1-hour
rainfall depths, click 'Run CUHP' to generate runoff
hydrographs using the embedded Colorado Urban
Hydrograph Procedure.
SDI_Design_Data_v2.00_Pond D - WQCV Only.xlsm, Design Data 8/17/2021, 4:28 PM
Booleans for Message Booleans for CUHP
Watershed L:W 1 CUHP Inputs Complete
Watershed Lc:L 1 CUHP Results Calculated
Watershed Slope FALSE Time Interval
RunOnce 1
CountA 1
Draintime Coeff 1.0
User Precip 1
Equal SA Inputs 1
Equal SD Inputs 1
Stormwater Detention and Infiltration Design Data Sheet
0
5
10
15
20
25
30
35
40
45
0.1 1 10FLOW [cfs]TIME [hr]
100YR IN
100YR OUT
50YR IN
50YR OUT
10YR IN
10YR OUT
5YR IN
5YR OUT
2YR IN
2YR OUT
WQCV IN
WQCV OUT
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
0.1 1 10 100PONDING DEPTH [ft]DRAIN TIME [hr]
100YR
50YR
10YR
5YR
2YR
WQCV
SDI_Design_Data_v2.00_Pond D - WQCV Only.xlsm, Design Data 8/17/2021, 4:28 PM
Stormwater Facility Name:
Facility Location & Jurisdiction:
User Input: Watershed Characteristics User Defined User Defined User Defined User Defined
Selected BMP Type =EDB Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs]
Watershed Area =31.32 acres 0.00 0 0.00 0.00
Watershed Length =1,750 ft 0.50 22,617 0.50 1.06
Watershed Length to Centroid =850 ft 1.00 28,204 1.00 2.65
Watershed Slope =0.010 ft/ft 2.00 32,998 2.00 5.02
Watershed Imperviousness =54.0%percent 3.00 38,019 3.00 6.30
Percentage Hydrologic Soil Group A =0.0%percent 4.00 43,264 4.00 7.55
Percentage Hydrologic Soil Group B =30.0%percent 5.00 48,736 5.00 8.77
Percentage Hydrologic Soil Groups C/D =70.0%percent 6.00 54,433 6.00 10.20
Target WQCV Drain Time =40.0 hours 6.50 56,800 6.50 12.42
User Input
After completing and printing this worksheet to a pdf, go to:
https://maperture.digitaldataservices.com/gvh/?viewer=cswdif
Create a new stormwater facility, and attach the PDF of this
worksheet to that record.
Routed Hydrograph Results
Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year
One-Hour Rainfall Depth =N/A 0.82 1.14 1.40 2.35 2.86 in
CUHP Runoff Volume =0.568 1.043 1.647 2.249 4.894 6.385 acre-ft
Inflow Hydrograph Volume =N/A 1.043 1.647 2.249 4.894 6.385 acre-ft
Time to Drain 97% of Inflow Volume =4.5 6.5 7.4 8.2 11.0 12.3 hours
Time to Drain 99% of Inflow Volume =5.0 7.1 8.2 9.1 12.3 13.8 hours
Maximum Ponding Depth =1.23 1.30 1.90 2.48 4.87 6.00 ft
Maximum Ponded Area =0.67 0.68 0.75 0.81 1.10 1.25 acres
Maximum Volume Stored =0.569 0.617 1.044 1.493 3.774 5.110 acre-ft
Once CUHP has been run and the Stage-Area-Discharge
information has been provided, click 'Process Data' to
interpolate the Stage-Area-Volume-Discharge data and
generate summary results in the table below. Once this
is complete, click 'Print to PDF'.
Stormwater Detention and Infiltration Design Data Sheet
Pond E
Mulberry
SDI-Design Data v2.00, Released January 2020
Location for 1-hr Rainfall Depths (use dropdown):
After providing required inputs above including 1-hour
rainfall depths, click 'Run CUHP' to generate runoff
hydrographs using the embedded Colorado Urban
Hydrograph Procedure.
SDI_Design_Data_v2.00_Pond E.xlsm, Design Data 8/17/2021, 5:18 PM
Booleans for Message Booleans for CUHP
Watershed L:W 1 CUHP Inputs Complete
Watershed Lc:L 1 CUHP Results Calculated
Watershed Slope FALSE Time Interval
RunOnce 1
CountA 1
Draintime Coeff 1.0
User Precip 1
Equal SA Inputs 1
Equal SD Inputs 1
Stormwater Detention and Infiltration Design Data Sheet
0
10
20
30
40
50
60
70
80
90
100
0.1 1 10FLOW[cfs]TIME [hr]
100YR IN
100YR OUT
50YR IN
50YR OUT
10YR IN
10YR OUT
5YR IN
5YR OUT
2YR IN
2YR OUT
WQCV IN
WQCV OUT
0
1
2
3
4
5
6
7
0.1 1 10 100PONDINGDEPTH[ft]DRAIN TIME [hr]
100YR
50YR
10YR
5YR
2YR
WQCV
SDI_Design_Data_v2.00_Pond E.xlsm, Design Data 8/17/2021, 5:18 PM
Stormwater Facility Name:
Facility Location & Jurisdiction:
User Input: Watershed Characteristics User Defined User Defined User Defined User Defined
Selected BMP Type =EDB Stage [ft]Area [ft^2]Stage [ft]Discharge [cfs]
Watershed Area =21.18 acres 0.00 0 0.00 0.00
Watershed Length =1,750 ft 0.50 22,617 0.50 1.06
Watershed Length to Centroid =850 ft 1.00 28,204 1.00 2.65
Watershed Slope =0.010 ft/ft 2.00 32,998 2.00 5.02
Watershed Imperviousness =65.2%percent 3.00 38,019 3.00 6.30
Percentage Hydrologic Soil Group A =0.0%percent 4.00 43,264 4.00 7.55
Percentage Hydrologic Soil Group B =30.0%percent 5.00 48,736 5.00 8.77
Percentage Hydrologic Soil Groups C/D =70.0%percent 6.00 54,433 6.00 10.20
Target WQCV Drain Time =40.0 hours 7.00 56,800 7.00 12.42
User Input
After completing and printing this worksheet to a pdf, go to:
https://maperture.digitaldataservices.com/gvh/?viewer=cswdif
Create a new stormwater facility, and attach the PDF of this
worksheet to that record.
Routed Hydrograph Results
Design Storm Return Period =WQCV 2 Year 5 Year 10 Year 50 Year 100 Year
One-Hour Rainfall Depth =N/A 0.82 1.14 1.40 2.35 2.86 in
CUHP Runoff Volume =0.450 0.871 1.331 1.763 3.558 4.558 acre-ft
Inflow Hydrograph Volume =N/A 0.871 1.331 1.763 3.558 4.558 acre-ft
Time to Drain 97% of Inflow Volume =4.2 6.2 6.9 7.6 9.8 10.8 hours
Time to Drain 99% of Inflow Volume =4.6 6.7 7.7 8.3 10.8 12.0 hours
Maximum Ponding Depth =1.05 1.12 1.59 1.99 3.74 4.61 ft
Maximum Ponded Area =0.65 0.66 0.71 0.76 0.96 1.07 acres
Maximum Volume Stored =0.450 0.497 0.817 1.115 2.615 3.494 acre-ft
Once CUHP has been run and the Stage-Area-Discharge
information has been provided, click 'Process Data' to
interpolate the Stage-Area-Volume-Discharge data and
generate summary results in the table below. Once this
is complete, click 'Print to PDF'.
Stormwater Detention and Infiltration Design Data Sheet
Pond E WQCV Drain Time Only
Mulberry
SDI-Design Data v2.00, Released January 2020
Location for 1-hr Rainfall Depths (use dropdown):
After providing required inputs above including 1-hour
rainfall depths, click 'Run CUHP' to generate runoff
hydrographs using the embedded Colorado Urban
Hydrograph Procedure.
SDI_Design_Data_v2.00_Pond E - WQCV Only.xlsm, Design Data 8/17/2021, 5:25 PM
Booleans for Message Booleans for CUHP
Watershed L:W 1 CUHP Inputs Complete
Watershed Lc:L 1 CUHP Results Calculated
Watershed Slope FALSE Time Interval
RunOnce 1
CountA 1
Draintime Coeff 1.0
User Precip 1
Equal SA Inputs 1
Equal SD Inputs 1
Stormwater Detention and Infiltration Design Data Sheet
0
10
20
30
40
50
60
70
0.1 1 10FLOW[cfs]TIME [hr]
100YR IN
100YR OUT
50YR IN
50YR OUT
10YR IN
10YR OUT
5YR IN
5YR OUT
2YR IN
2YR OUT
WQCV IN
WQCV OUT
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0.1 1 10 100PONDINGDEPTH[ft]DRAIN TIME [hr]
100YR
50YR
10YR
5YR
2YR
WQCV
SDI_Design_Data_v2.00_Pond E - WQCV Only.xlsm, Design Data 8/17/2021, 5:25 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =70.0 percent
Catchment Area, A =56.00 acres Diameter of holes, D =1.418 inches
Depth at WQCV outlet above lowest perforation, H =2.25 feet Number of holes per row, N =2
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =6.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):2.25
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.339 watershed inches
Water Quality Capture Volume (WQCV) =1.582 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =1.899 acre-feet
Outlet area per row, Ao =3.16 square inches
Total opening area at each row based on user-input above, Ao =3.16 square inches
Total opening area at each row based on user-input above, Ao =0.022 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4947.00 4947.33 4947.67 4948.00 4948.33 4948.67 Flow
4947.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4947.50 0.0809 0.0472 0.0000 0.0000 0.0000 0.0000 0.13
4948.00 0.1144 0.0936 0.0657 0.0000 0.0000 0.0000 0.27
4948.50 0.1401 0.1237 0.1042 0.0809 0.0472 0.0000 0.50
4949.00 0.1618 0.1478 0.1319 0.1144 0.0936 0.0657 0.72
4949.50 0.1809 0.1685 0.1547 0.1401 0.1237 0.1042 0.87
4950.00 0.1981 0.1869 0.1746 0.1618 0.1478 0.1319 1.00
4950.50 0.2140 0.2037 0.1924 0.1809 0.1685 0.1547 1.11
4951.00 0.2288 0.2191 0.2087 0.1981 0.1869 0.1746 1.22
4951.50 0.2427 0.2336 0.2239 0.2140 0.2037 0.1924 1.31
4952.00 0.2558 0.2472 0.2380 0.2288 0.2191 0.2087 1.40
4952.50 0.2683 0.2601 0.2514 0.2427 0.2336 0.2239 1.48
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond A
HFH22_Pond A WQCV.xls, WQCV 3/29/2022, 5:53 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond A
4946.00
4947.00
4948.00
4949.00
4950.00
4951.00
4952.00
4953.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond A WQCV.xls, WQCV 3/29/2022, 5:53 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =6.53
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =12.10
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =22.2
Percent of Design Flow =183%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =1.62
Flow area Ao =0.94
Top width of Orifice (inches)To =17.98
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.79
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.79
Resultant Peak Flow Through Orifice at Design Depth Qo =12.1
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =1.19
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.40
Bloom Filing 1
Pond A Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond A WQCV.xls, Restrictor Plate 7/12/2022, 2:49 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =70.0 percent
Catchment Area, A =15.30 acres Diameter of holes, D =1.002 inches
Depth at WQCV outlet above lowest perforation, H =3.50 feet Number of holes per row, N =1
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =10.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):3.5
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.339 watershed inches
Water Quality Capture Volume (WQCV) =0.432 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =0.519 acre-feet
Outlet area per row, Ao =0.79 square inches
Total opening area at each row based on user-input above, Ao =0.79 square inches
Total opening area at each row based on user-input above, Ao =0.005 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4941.00 4941.33 4941.67 4942.00 4942.33 4942.67 4943.00 4943.33 4943.67 4944.00 Flow
4941.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4941.50 0.0202 0.0118 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.03
4942.00 0.0286 0.0234 0.0164 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.07
4942.50 0.0350 0.0309 0.0260 0.0202 0.0118 0.0000 0.0000 0.0000 0.0000 0.0000 0.12
4943.00 0.0404 0.0369 0.0330 0.0286 0.0234 0.0164 0.0000 0.0000 0.0000 0.0000 0.18
4943.50 0.0452 0.0421 0.0387 0.0350 0.0309 0.0260 0.0202 0.0118 0.0000 0.0000 0.25
4944.00 0.0495 0.0467 0.0436 0.0404 0.0369 0.0330 0.0286 0.0234 0.0164 0.0000 0.32
4944.50 0.0535 0.0509 0.0481 0.0452 0.0421 0.0387 0.0350 0.0309 0.0260 0.0202 0.39
4945.00 0.0571 0.0547 0.0521 0.0495 0.0467 0.0436 0.0404 0.0369 0.0330 0.0286 0.44
4945.50 0.0606 0.0584 0.0559 0.0535 0.0509 0.0481 0.0452 0.0421 0.0387 0.0350 0.49
4946.00 0.0639 0.0618 0.0595 0.0571 0.0547 0.0521 0.0495 0.0467 0.0436 0.0404 0.53
4946.50 0.0670 0.0650 0.0628 0.0606 0.0584 0.0559 0.0535 0.0509 0.0481 0.0452 0.57
4947.00 0.0700 0.0680 0.0660 0.0639 0.0618 0.0595 0.0571 0.0547 0.0521 0.0495 0.60
4947.50 0.0729 0.0710 0.0690 0.0670 0.0650 0.0628 0.0606 0.0584 0.0559 0.0535 0.64
4948.00 0.0756 0.0738 0.0719 0.0700 0.0680 0.0660 0.0639 0.0618 0.0595 0.0571 0.67
4948.50 0.0783 0.0765 0.0747 0.0729 0.0710 0.0690 0.0670 0.0650 0.0628 0.0606 0.70
4949.00 0.0808 0.0791 0.0774 0.0756 0.0738 0.0719 0.0700 0.0680 0.0660 0.0639 0.73
4949.50 0.0833 0.0817 0.0800 0.0783 0.0765 0.0747 0.0729 0.0710 0.0690 0.0670 0.75
4950.00 0.0857 0.0841 0.0825 0.0808 0.0791 0.0774 0.0756 0.0738 0.0719 0.0700 0.78
4950.50 0.0881 0.0865 0.0849 0.0833 0.0817 0.0800 0.0783 0.0765 0.0747 0.0729 0.81
4951.00 0.0904 0.0889 0.0873 0.0857 0.0841 0.0825 0.0808 0.0791 0.0774 0.0756 0.83
4951.50 0.0926 0.0911 0.0896 0.0881 0.0865 0.0849 0.0833 0.0817 0.0800 0.0783 0.86
4952.00 0.0948 0.0933 0.0918 0.0904 0.0889 0.0873 0.0857 0.0841 0.0825 0.0808 0.88
4952.50 0.0969 0.0955 0.0940 0.0926 0.0911 0.0896 0.0881 0.0865 0.0849 0.0833 0.90
4953.00 0.0990 0.0976 0.0962 0.0948 0.0933 0.0918 0.0904 0.0889 0.0873 0.0857 0.92
4953.50 0.1010 0.0997 0.0983 0.0969 0.0955 0.0940 0.0926 0.0911 0.0896 0.0881 0.95
4954.00 0.1030 0.1017 0.1003 0.0990 0.0976 0.0962 0.0948 0.0933 0.0918 0.0904 0.97
4954.50 0.1050 0.1037 0.1024 0.1010 0.0997 0.0983 0.0969 0.0955 0.0940 0.0926 0.99
4955.00 0.1069 0.1056 0.1043 0.1030 0.1017 0.1003 0.0990 0.0976 0.0962 0.0948 1.01
4955.50 0.1088 0.1076 0.1063 0.1050 0.1037 0.1024 0.1010 0.0997 0.0983 0.0969 1.03
4956.00 0.1107 0.1094 0.1082 0.1069 0.1056 0.1043 0.1030 0.1017 0.1003 0.0990 1.05
4956.50 0.1125 0.1113 0.1100 0.1088 0.1076 0.1063 0.1050 0.1037 0.1024 0.1010 1.07
4957.00 0.1143 0.1131 0.1119 0.1107 0.1094 0.1082 0.1069 0.1056 0.1043 0.1030 1.09
4957.50 0.1161 0.1149 0.1137 0.1125 0.1113 0.1100 0.1088 0.1076 0.1063 0.1050 1.11
4958.00 0.1178 0.1167 0.1155 0.1143 0.1131 0.1119 0.1107 0.1094 0.1082 0.1069 1.12
4958.50 0.1195 0.1184 0.1172 0.1161 0.1149 0.1137 0.1125 0.1113 0.1100 0.1088 1.14
4959.00 0.1212 0.1201 0.1190 0.1178 0.1167 0.1155 0.1143 0.1131 0.1119 0.1107 1.16
4959.50 0.1229 0.1218 0.1207 0.1195 0.1184 0.1172 0.1161 0.1149 0.1137 0.1125 1.18
4960.00 0.1246 0.1235 0.1223 0.1212 0.1201 0.1190 0.1178 0.1167 0.1155 0.1143 1.19
4960.50 0.1262 0.1251 0.1240 0.1229 0.1218 0.1207 0.1195 0.1184 0.1172 0.1161 1.21
4961.00 0.1278 0.1267 0.1256 0.1246 0.1235 0.1223 0.1212 0.1201 0.1190 0.1178 1.23
4961.50 0.1294 0.1283 0.1272 0.1262 0.1251 0.1240 0.1229 0.1218 0.1207 0.1195 1.25
4962.00 0.1309 0.1299 0.1288 0.1278 0.1267 0.1256 0.1246 0.1235 0.1223 0.1212 1.26
4962.50 0.1325 0.1315 0.1304 0.1294 0.1283 0.1272 0.1262 0.1251 0.1240 0.1229 1.28
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond B
HFH22_Pond B WQCV.xls, WQCV 3/29/2022, 5:47 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond B
4935.00
4940.00
4945.00
4950.00
4955.00
4960.00
4965.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond B WQCV.xls, WQCV 3/29/2022, 5:47 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =7.11
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =8.60
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =23.3
Percent of Design Flow =270%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =1.34
Flow area Ao =0.63
Top width of Orifice (inches)To =17.53
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.58
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.58
Resultant Peak Flow Through Orifice at Design Depth Qo =8.6
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =1.09
Bloom Filing 1
Pond B Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond B WQCV.xls, Restrictor Plate 7/12/2022, 2:46 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =90.0 percent
Catchment Area, A =22.00 acres Diameter of holes, D =1.284 inches
Depth at WQCV outlet above lowest perforation, H =3.25 feet Number of holes per row, N =1
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =9.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):3.25
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.401 watershed inches
Water Quality Capture Volume (WQCV) =0.736 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =0.883 acre-feet
Outlet area per row, Ao =1.30 square inches
Total opening area at each row based on user-input above, Ao =1.30 square inches
Total opening area at each row based on user-input above, Ao =0.009 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4939.00 4939.33 4939.67 4940.00 4940.33 4940.67 4941.00 4941.33 4941.67 Flow
4939.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4939.50 0.0332 0.0194 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.05
4940.00 0.0469 0.0384 0.0270 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.11
4940.50 0.0575 0.0508 0.0428 0.0332 0.0194 0.0000 0.0000 0.0000 0.0000 0.20
4941.00 0.0664 0.0607 0.0541 0.0469 0.0384 0.0270 0.0000 0.0000 0.0000 0.29
4941.50 0.0742 0.0691 0.0635 0.0575 0.0508 0.0428 0.0332 0.0194 0.0000 0.41
4942.00 0.0813 0.0767 0.0716 0.0664 0.0607 0.0541 0.0469 0.0384 0.0270 0.52
4942.50 0.0878 0.0836 0.0790 0.0742 0.0691 0.0635 0.0575 0.0508 0.0428 0.61
4943.00 0.0939 0.0899 0.0857 0.0813 0.0767 0.0716 0.0664 0.0607 0.0541 0.68
4943.50 0.0996 0.0958 0.0919 0.0878 0.0836 0.0790 0.0742 0.0691 0.0635 0.74
4944.00 0.1050 0.1014 0.0977 0.0939 0.0899 0.0857 0.0813 0.0767 0.0716 0.80
4944.50 0.1101 0.1067 0.1032 0.0996 0.0958 0.0919 0.0878 0.0836 0.0790 0.86
4945.00 0.1150 0.1118 0.1084 0.1050 0.1014 0.0977 0.0939 0.0899 0.0857 0.91
4945.50 0.1197 0.1166 0.1133 0.1101 0.1067 0.1032 0.0996 0.0958 0.0919 0.96
4946.00 0.1242 0.1212 0.1181 0.1150 0.1118 0.1084 0.1050 0.1014 0.0977 1.00
4946.50 0.1285 0.1257 0.1227 0.1197 0.1166 0.1133 0.1101 0.1067 0.1032 1.05
4947.00 0.1328 0.1300 0.1271 0.1242 0.1212 0.1181 0.1150 0.1118 0.1084 1.09
4947.50 0.1368 0.1342 0.1313 0.1285 0.1257 0.1227 0.1197 0.1166 0.1133 1.13
4948.00 0.1408 0.1382 0.1355 0.1328 0.1300 0.1271 0.1242 0.1212 0.1181 1.17
4948.50 0.1447 0.1421 0.1395 0.1368 0.1342 0.1313 0.1285 0.1257 0.1227 1.21
4949.00 0.1484 0.1460 0.1434 0.1408 0.1382 0.1355 0.1328 0.1300 0.1271 1.24
4949.50 0.1521 0.1497 0.1472 0.1447 0.1421 0.1395 0.1368 0.1342 0.1313 1.28
4950.00 0.1557 0.1533 0.1509 0.1484 0.1460 0.1434 0.1408 0.1382 0.1355 1.31
4950.50 0.1592 0.1569 0.1545 0.1521 0.1497 0.1472 0.1447 0.1421 0.1395 1.35
4951.00 0.1626 0.1603 0.1580 0.1557 0.1533 0.1509 0.1484 0.1460 0.1434 1.38
4951.50 0.1659 0.1637 0.1614 0.1592 0.1569 0.1545 0.1521 0.1497 0.1472 1.41
4952.00 0.1692 0.1671 0.1648 0.1626 0.1603 0.1580 0.1557 0.1533 0.1509 1.44
4952.50 0.1725 0.1703 0.1681 0.1659 0.1637 0.1614 0.1592 0.1569 0.1545 1.47
4953.00 0.1756 0.1735 0.1714 0.1692 0.1671 0.1648 0.1626 0.1603 0.1580 1.50
4953.50 0.1787 0.1767 0.1745 0.1725 0.1703 0.1681 0.1659 0.1637 0.1614 1.53
4954.00 0.1818 0.1798 0.1777 0.1756 0.1735 0.1714 0.1692 0.1671 0.1648 1.56
4954.50 0.1848 0.1828 0.1807 0.1787 0.1767 0.1745 0.1725 0.1703 0.1681 1.59
4955.00 0.1877 0.1858 0.1838 0.1818 0.1798 0.1777 0.1756 0.1735 0.1714 1.62
4955.50 0.1907 0.1887 0.1867 0.1848 0.1828 0.1807 0.1787 0.1767 0.1745 1.64
4956.00 0.1935 0.1916 0.1897 0.1877 0.1858 0.1838 0.1818 0.1798 0.1777 1.67
4956.50 0.1963 0.1945 0.1926 0.1907 0.1887 0.1867 0.1848 0.1828 0.1807 1.70
4957.00 0.1991 0.1973 0.1954 0.1935 0.1916 0.1897 0.1877 0.1858 0.1838 1.72
4957.50 0.2019 0.2001 0.1982 0.1963 0.1945 0.1926 0.1907 0.1887 0.1867 1.75
4958.00 0.2046 0.2028 0.2010 0.1991 0.1973 0.1954 0.1935 0.1916 0.1897 1.77
4958.50 0.2073 0.2055 0.2037 0.2019 0.2001 0.1982 0.1963 0.1945 0.1926 1.80
4959.00 0.2099 0.2082 0.2064 0.2046 0.2028 0.2010 0.1991 0.1973 0.1954 1.82
4959.50 0.2125 0.2108 0.2090 0.2073 0.2055 0.2037 0.2019 0.2001 0.1982 1.85
4960.00 0.2151 0.2134 0.2116 0.2099 0.2082 0.2064 0.2046 0.2028 0.2010 1.87
4960.50 0.2176 0.2160 0.2142 0.2125 0.2108 0.2090 0.2073 0.2055 0.2037 1.90
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond C
HFH22_Pond C WQCV.xls, WQCV 3/29/2022, 5:21 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond C
4935.00
4940.00
4945.00
4950.00
4955.00
4960.00
4965.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond C WQCV.xls, WQCV 3/29/2022, 5:21 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =5.93
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =13.64
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =21.0
Percent of Design Flow =154%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =1.78
Flow area Ao =1.12
Top width of Orifice (inches)To =17.60
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.91
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.91
Resultant Peak Flow Through Orifice at Design Depth Qo =13.6
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =1.23
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.46
Bloom Filing 1
Pond C Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond C WQCV.xls, Restrictor Plate 7/12/2022, 2:45 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =51.0 percent
Catchment Area, A =35.68 acres Diameter of holes, D =1.495 inches
Depth at WQCV outlet above lowest perforation, H =2.50 feet Number of holes per row, N =2
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =7.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):2.5
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.274 watershed inches
Water Quality Capture Volume (WQCV) =0.815 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =0.979 acre-feet
Outlet area per row, Ao =1.65 square inches
Total opening area at each row based on user-input above, Ao =3.51 square inches
Total opening area at each row based on user-input above, Ao =0.024 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4944.50 4944.83 4945.17 4945.50 4945.83 4946.17 4946.50 Flow
4944.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
49.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4677.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4677.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4678.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4678.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4679.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4679.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4680.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4680.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4681.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4681.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4682.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4682.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4683.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4683.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4684.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4684.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4685.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4685.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4686.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4686.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4687.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4687.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4688.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4688.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4689.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4689.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4690.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4690.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4691.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4691.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4692.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4692.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4693.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4693.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4694.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4694.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4695.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4695.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4696.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4696.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4697.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4697.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond D
HFH22_Pond D WQCV.xls, WQCV 3/29/2022, 5:39 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond D
0.00
1000.00
2000.00
3000.00
4000.00
5000.00
6000.00
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond D WQCV.xls, WQCV 3/29/2022, 5:39 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =4.04
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =0.73
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =16.7
Percent of Design Flow =2290%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =0.59
Flow area Ao =0.07
Top width of Orifice (inches)To =9.95
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.13
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.13
Resultant Peak Flow Through Orifice at Design Depth Qo =0.7
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =0.54
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.07
Bloom Filing 1
Pond D Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond D WQCV.xls, Restrictor Plate 7/12/2022, 1:45 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =52.0 percent
Catchment Area, A =33.00 acres Diameter of holes, D =1.452 inches
Depth at WQCV outlet above lowest perforation, H =2.25 feet Number of holes per row, N =1
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =6.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):2.25
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.278 watershed inches
Water Quality Capture Volume (WQCV) =0.764 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =0.917 acre-feet
Outlet area per row, Ao =1.66 square inches
Total opening area at each row based on user-input above, Ao =1.66 square inches
Total opening area at each row based on user-input above, Ao =0.011 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4941.50 4941.83 4942.17 4942.50 4942.83 4943.17 Flow
4941.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4942.00 0.0424 0.0247 0.0000 0.0000 0.0000 0.0000 0.07
4942.50 0.0600 0.0491 0.0345 0.0000 0.0000 0.0000 0.14
4943.00 0.0735 0.0649 0.0546 0.0424 0.0247 0.0000 0.26
4943.50 0.0848 0.0775 0.0692 0.0600 0.0491 0.0345 0.38
4944.00 0.0948 0.0884 0.0811 0.0735 0.0649 0.0546 0.46
4944.50 0.1039 0.0980 0.0916 0.0848 0.0775 0.0692 0.52
4945.00 0.1122 0.1068 0.1009 0.0948 0.0884 0.0811 0.58
4945.50 0.1200 0.1149 0.1095 0.1039 0.0980 0.0916 0.64
4946.00 0.1272 0.1225 0.1174 0.1122 0.1068 0.1009 0.69
4946.50 0.1341 0.1296 0.1248 0.1200 0.1149 0.1095 0.73
4947.00 0.1407 0.1364 0.1318 0.1272 0.1225 0.1174 0.78
4947.50 0.1469 0.1428 0.1385 0.1341 0.1296 0.1248 0.82
4948.00 0.1529 0.1490 0.1448 0.1407 0.1364 0.1318 0.86
4948.50 0.1587 0.1549 0.1509 0.1469 0.1428 0.1385 0.89
4949.00 0.1643 0.1606 0.1568 0.1529 0.1490 0.1448 0.93
4949.50 0.1697 0.1661 0.1624 0.1587 0.1549 0.1509 0.96
4950.00 0.1749 0.1714 0.1678 0.1643 0.1606 0.1568 1.00
4950.50 0.1799 0.1766 0.1731 0.1697 0.1661 0.1624 1.03
4951.00 0.1849 0.1816 0.1782 0.1749 0.1714 0.1678 1.06
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
#N/A #N/A #N/A #N/A #N/A #N/A #N/A
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond E
HFH22_Pond E WQCV.xls, WQCV 3/29/2022, 5:43 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond E
4940.00
4942.00
4944.00
4946.00
4948.00
4950.00
4952.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond E WQCV.xls, WQCV 3/29/2022, 5:43 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =5.16
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =8.85
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =19.4
Percent of Design Flow =219%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =1.47
Flow area Ao =0.77
Top width of Orifice (inches)To =17.91
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.68
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.68
Resultant Peak Flow Through Orifice at Design Depth Qo =8.9
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =1.13
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.34
Bloom Filing 1
Pond E Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond E WQCV.xls, Restrictor Plate 7/12/2022, 1:44 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =90.0 percent
Catchment Area, A =40.30 acres Diameter of holes, D =1.593 inches
Depth at WQCV outlet above lowest perforation, H =3.75 feet Number of holes per row, N =1
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =11.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):3.75
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.401 watershed inches
Water Quality Capture Volume (WQCV) =1.348 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =1.617 acre-feet
Outlet area per row, Ao =1.99 square inches
Total opening area at each row based on user-input above, Ao =1.99 square inches
Total opening area at each row based on user-input above, Ao =0.014 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4929.00 4929.33 4929.67 4930.00 4930.33 4930.67 4931.00 4931.33 4931.67 4932.00 4932.33 Flow
4929.00 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4929.50 0.0511 0.0298 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.08
4930.00 0.0722 0.0591 0.0415 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.17
4930.50 0.0885 0.0781 0.0658 0.0511 0.0298 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.31
4931.00 0.1022 0.0933 0.0833 0.0722 0.0591 0.0415 0.0000 0.0000 0.0000 0.0000 0.0000 0.45
4931.50 0.1142 0.1064 0.0977 0.0885 0.0781 0.0658 0.0511 0.0298 0.0000 0.0000 0.0000 0.63
4932.00 0.1251 0.1180 0.1103 0.1022 0.0933 0.0833 0.0722 0.0591 0.0415 0.0000 0.0000 0.81
4932.50 0.1351 0.1286 0.1215 0.1142 0.1064 0.0977 0.0885 0.0781 0.0658 0.0511 0.0298 1.02
4933.00 0.1445 0.1384 0.1318 0.1251 0.1180 0.1103 0.1022 0.0933 0.0833 0.0722 0.0591 1.18
4933.50 0.1532 0.1475 0.1414 0.1351 0.1286 0.1215 0.1142 0.1064 0.0977 0.0885 0.0781 1.31
4934.00 0.1615 0.1561 0.1503 0.1445 0.1384 0.1318 0.1251 0.1180 0.1103 0.1022 0.0933 1.43
4934.50 0.1694 0.1642 0.1588 0.1532 0.1475 0.1414 0.1351 0.1286 0.1215 0.1142 0.1064 1.54
4935.00 0.1769 0.1720 0.1668 0.1615 0.1561 0.1503 0.1445 0.1384 0.1318 0.1251 0.1180 1.64
4935.50 0.1842 0.1794 0.1744 0.1694 0.1642 0.1588 0.1532 0.1475 0.1414 0.1351 0.1286 1.74
4936.00 0.1911 0.1866 0.1817 0.1769 0.1720 0.1668 0.1615 0.1561 0.1503 0.1445 0.1384 1.83
4936.50 0.1978 0.1934 0.1888 0.1842 0.1794 0.1744 0.1694 0.1642 0.1588 0.1532 0.1475 1.91
4937.00 0.2043 0.2001 0.1956 0.1911 0.1866 0.1817 0.1769 0.1720 0.1668 0.1615 0.1561 1.99
4937.50 0.2106 0.2065 0.2021 0.1978 0.1934 0.1888 0.1842 0.1794 0.1744 0.1694 0.1642 2.07
4938.00 0.2167 0.2127 0.2085 0.2043 0.2001 0.1956 0.1911 0.1866 0.1817 0.1769 0.1720 2.15
4938.50 0.2226 0.2187 0.2147 0.2106 0.2065 0.2021 0.1978 0.1934 0.1888 0.1842 0.1794 2.22
4939.00 0.2284 0.2246 0.2206 0.2167 0.2127 0.2085 0.2043 0.2001 0.1956 0.1911 0.1866 2.29
4939.50 0.2341 0.2304 0.2265 0.2226 0.2187 0.2147 0.2106 0.2065 0.2021 0.1978 0.1934 2.36
4940.00 0.2396 0.2360 0.2322 0.2284 0.2246 0.2206 0.2167 0.2127 0.2085 0.2043 0.2001 2.42
4940.50 0.2450 0.2414 0.2377 0.2341 0.2304 0.2265 0.2226 0.2187 0.2147 0.2106 0.2065 2.49
4941.00 0.2502 0.2468 0.2431 0.2396 0.2360 0.2322 0.2284 0.2246 0.2206 0.2167 0.2127 2.55
4941.50 0.2554 0.2520 0.2485 0.2450 0.2414 0.2377 0.2341 0.2304 0.2265 0.2226 0.2187 2.61
4942.00 0.2604 0.2571 0.2536 0.2502 0.2468 0.2431 0.2396 0.2360 0.2322 0.2284 0.2246 2.67
4942.50 0.2654 0.2621 0.2587 0.2554 0.2520 0.2485 0.2450 0.2414 0.2377 0.2341 0.2304 2.73
4943.00 0.2703 0.2671 0.2637 0.2604 0.2571 0.2536 0.2502 0.2468 0.2431 0.2396 0.2360 2.79
4943.50 0.2751 0.2719 0.2686 0.2654 0.2621 0.2587 0.2554 0.2520 0.2485 0.2450 0.2414 2.84
4944.00 0.2798 0.2767 0.2734 0.2703 0.2671 0.2637 0.2604 0.2571 0.2536 0.2502 0.2468 2.90
4944.50 0.2844 0.2813 0.2782 0.2751 0.2719 0.2686 0.2654 0.2621 0.2587 0.2554 0.2520 2.95
4945.00 0.2889 0.2859 0.2828 0.2798 0.2767 0.2734 0.2703 0.2671 0.2637 0.2604 0.2571 3.01
4945.50 0.2934 0.2905 0.2874 0.2844 0.2813 0.2782 0.2751 0.2719 0.2686 0.2654 0.2621 3.06
4946.00 0.2978 0.2949 0.2919 0.2889 0.2859 0.2828 0.2798 0.2767 0.2734 0.2703 0.2671 3.11
4946.50 0.3022 0.2993 0.2963 0.2934 0.2905 0.2874 0.2844 0.2813 0.2782 0.2751 0.2719 3.16
4947.00 0.3065 0.3036 0.3007 0.2978 0.2949 0.2919 0.2889 0.2859 0.2828 0.2798 0.2767 3.21
4947.50 0.3107 0.3079 0.3050 0.3022 0.2993 0.2963 0.2934 0.2905 0.2874 0.2844 0.2813 3.26
4948.00 0.3149 0.3121 0.3093 0.3065 0.3036 0.3007 0.2978 0.2949 0.2919 0.2889 0.2859 3.31
4948.50 0.3190 0.3163 0.3135 0.3107 0.3079 0.3050 0.3022 0.2993 0.2963 0.2934 0.2905 3.35
4949.00 0.3230 0.3204 0.3176 0.3149 0.3121 0.3093 0.3065 0.3036 0.3007 0.2978 0.2949 3.40
4949.50 0.3271 0.3244 0.3217 0.3190 0.3163 0.3135 0.3107 0.3079 0.3050 0.3022 0.2993 3.45
4950.00 0.3310 0.3284 0.3257 0.3230 0.3204 0.3176 0.3149 0.3121 0.3093 0.3065 0.3036 3.49
4950.50 0.3349 0.3324 0.3297 0.3271 0.3244 0.3217 0.3190 0.3163 0.3135 0.3107 0.3079 3.54
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond G
HFH22_Pond G WQCV.xls, WQCV 3/29/2022, 5:51 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond G
4925.00
4930.00
4935.00
4940.00
4945.00
4950.00
4955.00
0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond G WQCV.xls, WQCV 3/29/2022, 5:51 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =7.52
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =17.60
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =24.0
Percent of Design Flow =136%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =1.94
Flow area Ao =1.27
Top width of Orifice (inches)To =16.83
Height from Invert of Orifice to Bottom of Plate (feet)Yo =1.02
Elevation of Bottom of Plate Elev Plate Bottom Edge =1.02
Resultant Peak Flow Through Orifice at Design Depth Qo =17.6
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =1.25
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.51
Bloom Filing 1
Pond G Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond G WQCV.xls, Restrictor Plate 7/12/2022, 1:44 PM
Project:
Basin ID:
WQCV Design Volume (Input):
Catchment Imperviousness, Ia =80.0 percent
Catchment Area, A =16.65 acres Diameter of holes, D =1.126 inches
Depth at WQCV outlet above lowest perforation, H =3.00 feet Number of holes per row, N =1
Vertical distance between rows, h =4.00 inches OR
Number of rows, NL =9.00
Orifice discharge coefficient, Co =0.65 Height of slot, H =inches
Slope of Basin Trickle Channel, S =0.008 ft / ft Width of slot, W =inches
Time to Drain the Pond =40 hours
Watershed Design Information (Input):3
Percent Soil Type A =0 %
Percent Soil Type B =0 %
Percent Soil Type C/D =100 %
Outlet Design Information (Output):
Water Quality Capture Volume, WQCV =0.371 watershed inches
Water Quality Capture Volume (WQCV) =0.514 acre-feet 0.00
Design Volume (WQCV / 12 * Area * 1.2) Vol =0.617 acre-feet
Outlet area per row, Ao =1.00 square inches
Total opening area at each row based on user-input above, Ao =1.00 square inches
Total opening area at each row based on user-input above, Ao =0.007 square feet
3
Row 1 Row 2 Row 3 Row 4 Row 5 Row 6 Row 7 Row 8 Row 9 Row 10 Row 11 Row 12 Row 13 Row 14 Row 15 Row 16 Row 17 Row 18 Row 19 Row 20 Row 21 Row 22 Row 23 Row 23 S
4923.50 4923.83 4924.17 4924.50 4924.83 4925.17 4925.50 4925.83 4926.17 Flow
4923.50 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.00
4924.00 0.0255 0.0149 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.04
4924.50 0.0361 0.0295 0.0207 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.09
4925.00 0.0442 0.0390 0.0329 0.0255 0.0149 0.0000 0.0000 0.0000 0.0000 0.16
4925.50 0.0510 0.0466 0.0416 0.0361 0.0295 0.0207 0.0000 0.0000 0.0000 0.23
4926.00 0.0570 0.0531 0.0488 0.0442 0.0390 0.0329 0.0255 0.0149 0.0000 0.32
4926.50 0.0625 0.0589 0.0551 0.0510 0.0466 0.0416 0.0361 0.0295 0.0207 0.40
4927.00 0.0675 0.0642 0.0607 0.0570 0.0531 0.0488 0.0442 0.0390 0.0329 0.47
4927.50 0.0721 0.0691 0.0658 0.0625 0.0589 0.0551 0.0510 0.0466 0.0416 0.52
4928.00 0.0765 0.0737 0.0706 0.0675 0.0642 0.0607 0.0570 0.0531 0.0488 0.57
4928.50 0.0807 0.0779 0.0751 0.0721 0.0691 0.0658 0.0625 0.0589 0.0551 0.62
4929.00 0.0846 0.0820 0.0793 0.0765 0.0737 0.0706 0.0675 0.0642 0.0607 0.66
4929.50 0.0884 0.0859 0.0833 0.0807 0.0779 0.0751 0.0721 0.0691 0.0658 0.70
4930.00 0.0920 0.0896 0.0871 0.0846 0.0820 0.0793 0.0765 0.0737 0.0706 0.74
4930.50 0.0954 0.0932 0.0908 0.0884 0.0859 0.0833 0.0807 0.0779 0.0751 0.77
4931.00 0.0988 0.0966 0.0943 0.0920 0.0896 0.0871 0.0846 0.0820 0.0793 0.80
4931.50 0.1020 0.0999 0.0977 0.0954 0.0932 0.0908 0.0884 0.0859 0.0833 0.84
4932.00 0.1052 0.1031 0.1009 0.0988 0.0966 0.0943 0.0920 0.0896 0.0871 0.87
4932.50 0.1082 0.1062 0.1041 0.1020 0.0999 0.0977 0.0954 0.0932 0.0908 0.90
4933.00 0.1112 0.1092 0.1072 0.1052 0.1031 0.1009 0.0988 0.0966 0.0943 0.93
4933.50 0.1141 0.1122 0.1102 0.1082 0.1062 0.1041 0.1020 0.0999 0.0977 0.95
4934.00 0.1169 0.1150 0.1131 0.1112 0.1092 0.1072 0.1052 0.1031 0.1009 0.98
4934.50 0.1196 0.1178 0.1159 0.1141 0.1122 0.1102 0.1082 0.1062 0.1041 1.01
4935.00 0.1223 0.1206 0.1187 0.1169 0.1150 0.1131 0.1112 0.1092 0.1072 1.03
4935.50 0.1250 0.1232 0.1214 0.1196 0.1178 0.1159 0.1141 0.1122 0.1102 1.06
4936.00 0.1275 0.1258 0.1241 0.1223 0.1206 0.1187 0.1169 0.1150 0.1131 1.08
4936.50 0.1301 0.1284 0.1267 0.1250 0.1232 0.1214 0.1196 0.1178 0.1159 1.11
4937.00 0.1325 0.1309 0.1292 0.1275 0.1258 0.1241 0.1223 0.1206 0.1187 1.13
4937.50 0.1350 0.1334 0.1317 0.1301 0.1284 0.1267 0.1250 0.1232 0.1214 1.15
4938.00 0.1374 0.1358 0.1341 0.1325 0.1309 0.1292 0.1275 0.1258 0.1241 1.18
4938.50 0.1397 0.1382 0.1365 0.1350 0.1334 0.1317 0.1301 0.1284 0.1267 1.20
4939.00 0.1420 0.1405 0.1389 0.1374 0.1358 0.1341 0.1325 0.1309 0.1292 1.22
4939.50 0.1443 0.1428 0.1412 0.1397 0.1382 0.1365 0.1350 0.1334 0.1317 1.24
4940.00 0.1465 0.1450 0.1435 0.1420 0.1405 0.1389 0.1374 0.1358 0.1341 1.26
4940.50 0.1487 0.1473 0.1458 0.1443 0.1428 0.1412 0.1397 0.1382 0.1365 1.28
4941.00 0.1509 0.1495 0.1480 0.1465 0.1450 0.1435 0.1420 0.1405 0.1389 1.30
4941.50 0.1530 0.1516 0.1502 0.1487 0.1473 0.1458 0.1443 0.1428 0.1412 1.32
4942.00 0.1551 0.1538 0.1523 0.1509 0.1495 0.1480 0.1465 0.1450 0.1435 1.34
4942.50 0.1572 0.1559 0.1544 0.1530 0.1516 0.1502 0.1487 0.1473 0.1458 1.36
4943.00 0.1593 0.1579 0.1565 0.1551 0.1538 0.1523 0.1509 0.1495 0.1480 1.38
4943.50 0.1613 0.1600 0.1586 0.1572 0.1559 0.1544 0.1530 0.1516 0.1502 1.40
4944.00 0.1633 0.1620 0.1606 0.1593 0.1579 0.1565 0.1551 0.1538 0.1523 1.42
4944.50 0.1653 0.1640 0.1626 0.1613 0.1600 0.1586 0.1572 0.1559 0.1544 1.44
4945.00 0.1673 0.1660 0.1646 0.1633 0.1620 0.1606 0.1593 0.1579 0.1565 1.46
Override
Area
Row 1
Override
Area
Row 2
Override
Area
Row 3
Override
Area
Row 4
Override
Area
Row 5
Override
Area
Row 6
Override
Area
Row 7
Override
Area
Row 8
Override
Area
Row 9
Override
Area
Row 10
Override
Area
Row 11
Override
Area
Row 12
Override
Area
Row 13
Override
Area
Row 14
Override
Area
Row 15
Override
Area
Row 16
Override
Area
Row 17
Override
Area
Row 18
Override
Area
Row 19
Override
Area
Row 20
Override
Area
Row 21
Override
Area
Row 22
Override
Area
Row 23
Override
Area
Row 24
Central Elevations of Rows of Holes in feet
Collection Capacity for Each Row of Holes in cfs
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond H
HFH22_Pond H WQCV.xls, WQCV 3/29/2022, 5:52 PM
Worksheet Protected
Project:
Basin ID:
STAGE-DISCHARGE SIZING OF THE WATER QUALITY CAPTURE VOLUME (WQCV) OUTLET
Bloom Filing 1
Pond H
4920.00
4925.00
4930.00
4935.00
4940.00
4945.00
4950.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60
Stage(feet,elev.)Discharge (cfs)
STAGE-DISCHARGE CURVE FOR THE WQCV OUTLET STRUCTURE
HFH22_Pond H WQCV.xls, WQCV 3/29/2022, 5:52 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =8.00
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =4.23
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =24.8
Percent of Design Flow =587%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =0.98
Flow area Ao =0.29
Top width of Orifice (inches)To =14.94
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.33
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.33
Resultant Peak Flow Through Orifice at Design Depth Qo =4.2
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =0.88
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.17
Bloom Filing 1
Pond H Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond H WQCV.xls, Restrictor Plate 7/12/2022, 2:50 PM
Project:
Basin ID:
X
1
#1 Vertical #2 Vertical
Sizing the Restrictor Plate for Circular Vertical Orifices or Pipes (Input)Orifice Orifice
Water Surface Elevation at Design Depth Elev: WS =5.54
Pipe/Vertical Orifice Entrance Invert Elevation Elev: Invert =0.00
Required Peak Flow through Orifice at Design Depth Q =0.35
Pipe/Vertical Orifice Diameter (inches)Dia =18.0
Orifice Coefficient Co =0.65
Full-flow Capacity (Calculated)
Full-flow area Af =1.77
Half Central Angle in Radians Theta =3.14
Full-flow capacity Qf =20.2
Percent of Design Flow =5763%
Calculation of Orifice Flow Condition
Half Central Angle (0<Theta<3.1416)Theta =0.43
Flow area Ao =0.03
Top width of Orifice (inches)To =7.50
Height from Invert of Orifice to Bottom of Plate (feet)Yo =0.07
Elevation of Bottom of Plate Elev Plate Bottom Edge =0.07
Resultant Peak Flow Through Orifice at Design Depth Qo =0.4
Width of Equivalent Rectangular Vertical Orifice Equivalent Width =0.43
Centroid Elevation of Equivalent Rectangular Vertical Orifice Equiv. Centroid El. =0.04
Bloom Filing 1
Pond I Restrictor Plate
RESTRICTOR PLATE SIZING FOR CIRCULAR VERTICAL ORIFICES
HFH22_Pond I WQCV.xls, Restrictor Plate 7/12/2022, 1:43 PM
Bloom Filing 1
Final Drainage Report
LID Calculations
Treated Added
Impervious
Area (acres)
Volume Provided
(cu.ft)
8.75 8500
0.76 10625
0.76 918
0.76 906
11.03
0.76 1142
0.76 900
0.73 893
0.76 1430
0.76 1210
0.76 1210
0.75 1717
0.75 1716
6.03
Min. Treated
Area (acres)Total Percentage
Treated
7.82 71%
4.77 63%
12.60 68%
Volume Req.
(cu.ft)
E1
E2
E7
Tributary
Area (acres)
10083
875
869
625
Tributary Basins
1.06
1.07
0.77
Total Treatment D Basins
Stormwater Quality Strategy
1 - Sand Filter
2 - Sand Filter
3 - Bioretention
4 - Bioretention
E5
E9
11 - Bioretention
10 - Bioretention
6 - Bioretention
7 - Bioretention
8 - Bioretention
9 - Bioretention
5 - Bioretention
37.17
28.49
877
877
Total Treatment E Basins
0.99
0.99
E22
E2313 - Bioretention
D1, D3.1, D3, D4, D12,
D21, D21.1
D2,D5, D6, D7, D8,
D8.1, D9, D10, D11,
D13, D14, D15, D15.1
D17
D16
LID SUMMARY
Basin E Treatment 9.55 6.03
Basin D Treatment 15.65 11.03
Tributary Basin
Total added
Impervious
(acres)
Total Treated
Area (Acres)
869
Site Treatment 25.20 17.07
880
4615
E10
850
865
1.07
0.96
1.03
861
1.07
1.03
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =44.0 %
(100% if all paved and roofed areas upstream of sand filter)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.440
C) Water Quality Capture Volume (WQCV) Based on 12-hour Drain Time WQCV =0.15 watershed inches
WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including sand filter area)Area = 363,726 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =4,615 cu ft
VWQCV = WQCV / 12 * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth DWQCV =3.0 ft
B) Sand Filter Side Slopes (Horizontal distance per unit vertical,Z =4.00 ft / ft
4:1 or flatter preferred). Use "0" if sand filter has vertical walls.
C) Minimum Filter Area (Flat Surface Area)AMin =2000 sq ft
D) Actual Filter Area AActual =2000 sq ft
E) Volume Provided VT =8500 cu ft
3. Filter Material
4. Underdrain System
A) Are underdrains provided?2
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =N/A ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =N/A cu ft
iii) Orifice Diameter, 3/8" Minimum DO =N/A in
Mulberry Filing 1
LID 1 (Basin D1, D3.1, D3, D4,D12 D21)
Design Procedure Form: Sand Filter (SF)
M. Pepin
Galloway
May 25, 2022
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" CDOT Class B or C Filter Material
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_1.xlsm, SF 5/25/2022, 10:46 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Works
A) Describe the type of energy dissipation at inlet points and means of
conveying flows in excess of the WQCV through the outlet
Notes:
Design Procedure Form: Sand Filter (SF)
M. Pepin
Galloway
May 25, 2022
Mulberry Filing 1
LID 1 (Basin D1, D3.1, D3, D4,D12 D21)
Choose One
YES NO
HFH22_UD-BMP_v3.07_LID_1.xlsm, SF 5/25/2022, 10:46 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =57.0 %
(100% if all paved and roofed areas upstream of sand filter)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.570
C) Water Quality Capture Volume (WQCV) Based on 12-hour Drain Time WQCV =0.18 watershed inches
WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including sand filter area)Area = 667,774 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =10,083 cu ft
VWQCV = WQCV / 12 * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth DWQCV =3.0 ft
B) Sand Filter Side Slopes (Horizontal distance per unit vertical,Z =4.00 ft / ft
4:1 or flatter preferred). Use "0" if sand filter has vertical walls.
C) Minimum Filter Area (Flat Surface Area)AMin =4758 sq ft
D) Actual Filter Area AActual =5000 sq ft
E) Volume Provided VT =10625 cu ft
3. Filter Material
4. Underdrain System
A) Are underdrains provided?2
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =N/A ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =N/A cu ft
iii) Orifice Diameter, 3/8" Minimum DO =N/A in
Mulberry Filing 1
LID 2 Tributary (D2, D5, D6, D8, D9, D11, D15, D18, D22)
Design Procedure Form: Sand Filter (SF)
M. Pepin
Galloway
May 25, 2022
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" CDOT Class B or C Filter Material
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_2.xlsm, SF 5/25/2022, 11:01 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Works
A) Describe the type of energy dissipation at inlet points and means of
conveying flows in excess of the WQCV through the outlet
Notes:
Design Procedure Form: Sand Filter (SF)
M. Pepin
Galloway
May 25, 2022
Mulberry Filing 1
LID 2 Tributary (D2, D5, D6, D8, D9, D11, D15, D18, D22)
Choose One
YES NO
HFH22_UD-BMP_v3.07_LID_2.xlsm, SF 5/25/2022, 11:01 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =72.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.720
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.23 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =46,173 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =875 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =9 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =665 sq ft
D) Actual Flat Surface Area AActual =670 sq ft
E) Area at Design Depth (Top Surface Area)ATop =1777 sq ft
F) Rain Garden Total Volume VT=918 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =125.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =875 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =5/16 in LESS THAN MINIMUM. USE DIAMETER OF 3/8"
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 3 (Tributary D17)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_3.xlsm, RG 7/12/2022, 10:22 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 3 (Tributary D17)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_3.xlsm, RG 7/12/2022, 10:22 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =71.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.710
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.22 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =46,609 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =869 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =9 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =662 sq ft
D) Actual Flat Surface Area AActual =675 sq ft
E) Area at Design Depth (Top Surface Area)ATop =1740 sq ft
F) Rain Garden Total Volume VT=906 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =125.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =869 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =5/16 in LESS THAN MINIMUM. USE DIAMETER OF 3/8"
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 4 (Tributary D16)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_4.xlsm, RG 7/12/2022, 10:21 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 4 (Tributary D16)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_4.xlsm, RG 7/12/2022, 10:21 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =71.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.710
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.22 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =33,541 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =625 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =6 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =476 sq ft
D) Actual Flat Surface Area AActual =1559 sq ft
E) Area at Design Depth (Top Surface Area)ATop =3007 sq ft
F) Rain Garden Total Volume VT=1,142 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =335.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =625 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/16 in LESS THAN MINIMUM. USE DIAMETER OF 3/8"
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 5 (Tributary E5)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_5.xlsm, RG 7/12/2022, 10:20 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 5 (Tributary E5)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_5.xlsm, RG 7/12/2022, 10:20 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =71.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.710
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.22 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =46,173 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =861 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =9 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =656 sq ft
D) Actual Flat Surface Area AActual =660 sq ft
E) Area at Design Depth (Top Surface Area)ATop =1740 sq ft
F) Rain Garden Total Volume VT=900 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =335.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =861 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =1/4 in LESS THAN MINIMUM. USE DIAMETER OF 3/8"
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 6 (Tributary E1)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_6.xlsm, RG 7/12/2022, 10:19 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 6 (Tributary E1)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_6.xlsm, RG 7/12/2022, 10:19 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =76.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.760
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.24 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =41,817 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =850 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =9 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =636 sq ft
D) Actual Flat Surface Area AActual =640 sq ft
E) Area at Design Depth (Top Surface Area)ATop =1740 sq ft
F) Rain Garden Total Volume VT=893 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =30.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =850 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/8 in
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 7 (Tributary E2)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_7.xlsm, RG 7/12/2022, 10:19 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 7 (Tributary E2)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_7.xlsm, RG 7/12/2022, 10:19 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =73.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.730
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.23 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =44,866 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =865 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =6 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =655 sq ft
D) Actual Flat Surface Area AActual =1588 sq ft
E) Area at Design Depth (Top Surface Area)ATop =4130 sq ft
F) Rain Garden Total Volume VT=1,430 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =30.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =865 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/8 in
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 8 (Tributary E7)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_8.xlsm, RG 7/12/2022, 10:18 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 8 (Tributary E7)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_8.xlsm, RG 7/12/2022, 10:18 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =71.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.710
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.22 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =46,609 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =869 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =6 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =662 sq ft
D) Actual Flat Surface Area AActual =665 sq ft
E) Area at Design Depth (Top Surface Area)ATop =4175 sq ft
F) Rain Garden Total Volume VT=1,210 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =30.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =869 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/8 in
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 9 (Tributary E9)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_9.xlsm, RG 7/12/2022, 10:17 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 9 (Tributary E9)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_9.xlsm, RG 7/12/2022, 10:17 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =74.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.740
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.24 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =44,866 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =880 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =6 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =664 sq ft
D) Actual Flat Surface Area AActual =665 sq ft
E) Area at Design Depth (Top Surface Area)ATop =4175 sq ft
F) Rain Garden Total Volume VT=1,210 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =30.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =880 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/8 in
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 10 (Tributary E10)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_10.xlsm, RG 7/12/2022, 10:17 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 10 (Tributary E10)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_10.xlsm, RG 7/12/2022, 10:17 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =76.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.760
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.24 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =43,124 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =877 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =6 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =655 sq ft
D) Actual Flat Surface Area AActual =2764 sq ft
E) Area at Design Depth (Top Surface Area)ATop =4102 sq ft
F) Rain Garden Total Volume VT=1,717 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =30.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =877 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/8 in
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 11 (Tributary E22)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_11.xlsm, RG 7/12/2022, 10:15 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 11 (Tributary E22)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_11.xlsm, RG 7/12/2022, 10:15 AM
Sheet 1 of 2
Designer:
Company:
Date:
Project:
Location:
1. Basin Storage Volume
A) Effective Imperviousness of Tributary Area, Ia Ia =76.0 %
(100% if all paved and roofed areas upstream of rain garden)
B) Tributary Area's Imperviousness Ratio (i = Ia/100)i =0.760
C) Water Quality Capture Volume (WQCV) for a 12-hour Drain Time WQCV =0.24 watershed inches
(WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i)
D) Contributing Watershed Area (including rain garden area)Area =43,124 sq ft
E) Water Quality Capture Volume (WQCV) Design Volume VWQCV =877 cu ft
Vol = (WQCV / 12) * Area
F) For Watersheds Outside of the Denver Region, Depth of d6 = in
Average Runoff Producing Storm
G) For Watersheds Outside of the Denver Region,VWQCV OTHER =cu ft
Water Quality Capture Volume (WQCV) Design Volume
H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER =cu ft
(Only if a different WQCV Design Volume is desired)
2. Basin Geometry
A) WQCV Depth (12-inch maximum)DWQCV =6 in
B) Rain Garden Side Slopes (Z = 4 min., horiz. dist per unit vertical)Z =4.00 ft / ft
(Use "0" if rain garden has vertical walls)
C) Mimimum Flat Surface Area AMin =655 sq ft
D) Actual Flat Surface Area AActual =2764 sq ft
E) Area at Design Depth (Top Surface Area)ATop =4100 sq ft
F) Rain Garden Total Volume VT=1,716 cu ft
(VT= ((ATop + AActual) / 2) * Depth)
3. Growing Media
4. Underdrain System
A) Are underdrains provided?1
B) Underdrain system orifice diameter for 12 hour drain time
i) Distance From Lowest Elevation of the Storage y =30.0 ft
Volume to the Center of the Orifice
ii) Volume to Drain in 12 Hours Vol12 =877 cu ft
iii) Orifice Diameter, 3/8" Minimum DO =3/8 in
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 13 (Tributary E23)
UD-BMP (Version 3.07, March 2018)
Choose One
Choose One
18" Rain Garden Growing Media
Other (Explain):
YES
NO
HFH22_UD-BMP_v3.07_LID_13.xlsm, RG 7/12/2022, 10:13 AM
Sheet 2 of 2
Designer:
Company:
Date:
Project:
Location:
5. Impermeable Geomembrane Liner and Geotextile Separator Fabric
A) Is an impermeable liner provided due to proximity
of structures or groundwater contamination?
6. Inlet / Outlet Control
A) Inlet Control
7. Vegetation
8. Irrigation
A) Will the rain garden be irrigated?
Notes:
Design Procedure Form: Rain Garden (RG)
M. Pepin
Galloway
July 12, 2022
Mulberry Filing 1
LID 13 (Tributary E23)
Choose One
Choose One
Choose One
Sheet Flow- No Energy Dissipation Required
Concentrated Flow- Energy Dissipation Provided
Plantings
Seed (Plan for frequent weed control)
Sand Grown or Other High Infiltration Sod
Choose One
YES
NO
YES
NO
HFH22_UD-BMP_v3.07_LID_13.xlsm, RG 7/12/2022, 10:13 AM
Subdivision:0 Project Name:Mulberry Filing 1
Location:CO, Fort Collins Project No.:HFH22
Calculated By:MJP
Checked By:JP
Date:8/3/21
DP-18.1 DP-D22 FUT-B
FUT-C
(Cooper
Slough)
DP-E20 G2 G3 G7
Q100 (cfs)37.2 38.0 17.2 23.0 54.5 13.9 84.3 32.8 Flows are the greater of proposed vs.
future
D or H (in)36 48 24 30 42 28.8 54 36
W (ft)3.8
Slope (%)0.30 0.3 0.4 0.1 0.4 0.4 0.2 0.1
Yn (in)23.16 23.50 18.00 19.60 29.00 12.00 43.20 19.80
Yt (ft)2.00 2.00 1.50 1.50 2.00 1.00 3.60 2.00 If "unknown" Yt/D=0.4
Yt/D, Yt/H 0.67 0.50 0.75 0.60 0.57 0.42 0.80 0.67 Per section 11-3
Supercritical Yes Yes Yes Yes Yes Yes Yes Yes
Q/D^2.5, Q/WH^1.5 2.39 1.19 3.04 2.33 2.38 0.98 1.96 2.10
Q/D^1.5, Q/WH^0.5
Da, Ha (in) *29.58 35.75 21.00 24.80 35.50 20.40 48.60 27.90 Da=0.5(D+Yn), Ha=0.5(H+Yn)
Q/Da^1.5, Q/WHa^0.5 *9.61 7.39 7.43 7.74 10.71 2.81 10.34 9.25
d50 (in), Required 4.50 4.89 3.02 4.12 6.04 1.13 3.89 4.33
Required Riprap Size L L L L L L L L Fig. 8-34
Use Riprap Size L L L L L L L L
d50 (in)9 9 9 9 9 9 9 9 Fig. 8-34
1/(2 tan q)4.30 0.00 2.00 1.00 2.00 0.00 0.00 0.00 Fig. 9-35 OR Fig 9-36
Erosive Soils Yes Yes Yes Yes Yes Yes Yes Yes
At 6.76 6.91 3.13 4.18 9.91 2.53 15.33 5.96 At=Q/5.5
L 1.6 0.0 0.2 0.3 2.9 0.0 0.0 0.0 L=(1/(2 tan q))(At/Yt - D)
Min L 9.0 12.0 6.0 7.5 10.5 7.2 13.5 9.0 Min L=3D or 3H
Max L 30.0 40.0 20.0 25.0 35.0 24.0 45.0 30.0 Max L=10D or 10H
Length (ft)9.0 12.0 6.0 7.5 10.5 7.2 13.5 9.0
Bottom Width (ft)9.0 12.0 6.0 7.5 10.5 7.2 13.5 9.0 Width=3D (Minimum)
Riprap Depth (in)18 18 18 18 18 18 18 18 Depth=2(d50)
Type II Base Depth (in)6 6 6 6 6 6 6 6 Table 8-34 fine grained soils)
Cutoff Wall No No No No No No No No
Cutoff Wall Depth (ft)Depth of Riprap and Base
Cutoff Wall Width (ft)
PIPE OUTFALL RIPRAP SIZING CALCULATIONS
STORM DRAIN SYSTEM
Bloom Filing 1
Final Drainage Report
APPENDIX E
SWMM Models
Bloom Filing 1
Final Drainage Report
Existing Condition SWMM Model
H1
H4
H3
H2
CooperSlough
LakeCanal O1
CityofFortCollins
Mulberry - Existing Conditions
SWMM 5.1 Page 1
Mulberry - Existing SWMM - Input
[TITLE]
;;Project Title/Notes
[OPTIONS]
;;Option Value
FLOW_UNITS CFS
INFILTRATION HORTON
FLOW_ROUTING KINWAVE
LINK_OFFSETS DEPTH
MIN_SLOPE 0
ALLOW_PONDING NO
SKIP_STEADY_STATE NO
START_DATE 03/19/2021
START_TIME 00:00:00
REPORT_START_DATE 03/19/2021
REPORT_START_TIME 00:00:00
END_DATE 03/19/2021
END_TIME 06:00:00
SWEEP_START 01/01
SWEEP_END 12/31
DRY_DAYS 0
REPORT_STEP 00:15:00
WET_STEP 00:05:00
DRY_STEP 01:00:00
ROUTING_STEP 0:00:30
RULE_STEP 00:00:00
INERTIAL_DAMPING PARTIAL
NORMAL_FLOW_LIMITED BOTH
FORCE_MAIN_EQUATION H-W
VARIABLE_STEP 0.75
LENGTHENING_STEP 0
MIN_SURFAREA 12.566
MAX_TRIALS 8
HEAD_TOLERANCE 0.005
SYS_FLOW_TOL 5
LAT_FLOW_TOL 5
MINIMUM_STEP 0.5
THREADS 1
[EVAPORATION]
;;Data Source Parameters
;;-------------- ----------------
CONSTANT 0.0
DRY_ONLY NO
[RAINGAGES]
;;Name Format Interval SCF Source
;;-------------- --------- ------ ------ ----------
CityofFortCollins INTENSITY 0:05 1.0 TIMESERIES FC_2year
[SUBCATCHMENTS]
;;Name Rain Gage Outlet Area %Imperv Width %Slope
CurbLen SnowPack
;;-------------- ---------------- ---------------- -------- -------- -------- --------
Mulberry - Existing SWMM - Input
-------- ----------------
H1 CityofFortCollins CooperSlough 72 2 1000 1.5 0
H4 CityofFortCollins LakeCanal 6.5 2 400 1.0 0
H3 CityofFortCollins O1 162 2 1200 1.0 0
H2 CityofFortCollins CooperSlough 22 2 600 1.0 0
[SUBAREAS]
;;Subcatchment N-Imperv N-Perv S-Imperv S-Perv PctZero RouteTo
PctRouted
;;-------------- ---------- ---------- ---------- ---------- ---------- ----------
----------
H1 0.016 0.25 0.1 0.3 1 OUTLET
H4 0.016 0.25 0.1 0.3 1 OUTLET
H3 0.016 0.25 0.1 0.3 1 OUTLET
H2 0.016 0.25 0.1 0.3 1 OUTLET
[INFILTRATION]
;;Subcatchment Param1 Param2 Param3 Param4 Param5
;;-------------- ---------- ---------- ---------- ---------- ----------
H1 0.51 0.5 6.48 7 0
H4 0.51 0.5 6.48 7 0
H3 0.51 0.5 6.48 7 0
H2 0.51 0.5 6.48 7 0
[OUTFALLS]
;;Name Elevation Type Stage Data Gated Route To
;;-------------- ---------- ---------- ---------------- -------- ----------------
CooperSlough 0 FREE NO
LakeCanal 0 FREE NO
O1 0 FREE NO
[TIMESERIES]
;;Name Date Time Value
;;-------------- ---------- ---------- ----------
FC_2year 0:05 0.29
FC_2year 0:10 0.33
FC_2year 0:15 0.38
FC_2year 0:20 0.64
FC_2year 0:25 0.81
FC_2year 0:30 1.57
FC_2year 0:35 2.85
FC_2year 0:40 1.18
FC_2year 0:45 0.71
FC_2year 0:50 0.42
FC_2year 0:55 0.35
FC_2year 1:00 0.30
FC_2year 1:05 0.20
FC_2year 1:10 0.19
FC_2year 1:15 0.18
FC_2year 1:20 0.17
FC_2year 1:25 0.17
FC_2year 1:30 0.16
Mulberry - Existing SWMM - Input
FC_2year 1:35 0.15
FC_2year 1:40 0.15
FC_2year 1:45 0.14
FC_2year 1:50 0.14
FC_2year 1:55 0.13
FC_2year 2:00 0.13
;
FC_100yr 0:05 1.00
FC_100yr 0:10 1.14
FC_100yr 0:15 1.33
FC_100yr 0:20 2.23
FC_100yr 0:25 2.84
FC_100yr 0:30 5.49
FC_100yr 0:35 9.95
FC_100yr 0:40 4.12
FC_100yr 0:45 2.48
FC_100yr 0:50 1.46
FC_100yr 0:55 1.22
FC_100yr 1:00 1.06
FC_100yr 1:05 1.00
FC_100yr 1:10 0.95
FC_100yr 1:15 0.91
FC_100yr 1:20 0.87
FC_100yr 1:25 0.84
FC_100yr 1:30 0.81
FC_100yr 1:35 0.78
FC_100yr 1:40 0.75
FC_100yr 1:45 0.73
FC_100yr 1:50 0.71
FC_100yr 1:55 0.69
FC_100yr 2:00 0.67
[REPORT]
;;Reporting Options
SUBCATCHMENTS ALL
NODES ALL
LINKS ALL
[TAGS]
[MAP]
DIMENSIONS -2215.333 0.000 12215.333 10000.000
Units None
[COORDINATES]
;;Node X-Coord Y-Coord
;;-------------- ------------------ ------------------
CooperSlough 5799.537 4855.156
LakeCanal 3018.540 1714.948
O1 4327.926 1680.185
[VERTICES]
;;Link X-Coord Y-Coord
;;-------------- ------------------ ------------------
[Polygons]
Mulberry - Existing SWMM - Input
;;Subcatchment X-Coord Y-Coord
;;-------------- ------------------ ------------------
H1 2694.090 8621.089
H1 5938.586 5121.669
H1 5938.586 8574.739
H1 2636.153 8621.089
H4 2439.166 2387.022
H4 2358.053 2479.722
H4 2392.816 1460.023
H4 2949.015 1436.848
H4 2867.903 1958.285
H4 2439.166 2421.784
H3 2427.578 8551.564
H3 2392.816 2595.597
H3 3064.890 1946.698
H3 3227.115 1448.436
H3 4154.114 1448.436
H3 4130.939 5052.144
H3 4154.114 6848.204
H3 2427.578 8551.564
H2 4281.576 6709.154
H2 4281.576 6709.154
H2 4269.988 5098.494
H2 5730.012 5075.319
H2 4293.163 6720.742
[SYMBOLS]
;;Gage X-Coord Y-Coord
;;-------------- ------------------ ------------------
CityofFortCollins 4222.097 8895.152
[BACKDROP]
FILE "H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\Drain
Reports\Prop\Aerial\Aerial.jpg"
DIMENSIONS -2215.333 200.301 12215.333 9799.699
Mulberry - Existing SWMM - 2-yr Results
EPA STORM WATER MANAGEMENT MODEL - VERSION 5.1 (Build 5.1.015)
--------------------------------------------------------------
*********************************************************
NOTE: The summary statistics displayed in this report are
based on results found at every computational time step,
not just on results from each reporting time step.
*********************************************************
****************
Analysis Options
****************
Flow Units ............... CFS
Process Models:
Rainfall/Runoff ........ YES
RDII ................... NO
Snowmelt ............... NO
Groundwater ............ NO
Flow Routing ........... NO
Water Quality .......... NO
Infiltration Method ...... HORTON
Starting Date ............ 03/19/2021 00:00:00
Ending Date .............. 03/19/2021 06:00:00
Antecedent Dry Days ...... 0.0
Report Time Step ......... 00:15:00
Wet Time Step ............ 00:05:00
Dry Time Step ............ 01:00:00
************************** Volume Depth
Runoff Quantity Continuity acre-feet inches
************************** --------- -------
Total Precipitation ...... 21.401 0.978
Evaporation Loss ......... 0.000 0.000
Infiltration Loss ........ 20.956 0.958
Surface Runoff ........... 0.408 0.019
Final Storage ............ 0.043 0.002
Continuity Error (%) ..... -0.027
Mulberry - Existing SWMM - 2-yr Results
************************** Volume Volume
Flow Routing Continuity acre-feet 10^6 gal
************************** --------- ---------
Dry Weather Inflow ....... 0.000 0.000
Wet Weather Inflow ....... 0.408 0.133
Groundwater Inflow ....... 0.000 0.000
RDII Inflow .............. 0.000 0.000
External Inflow .......... 0.000 0.000
External Outflow ......... 0.408 0.133
Flooding Loss ............ 0.000 0.000
Evaporation Loss ......... 0.000 0.000
Exfiltration Loss ........ 0.000 0.000
Initial Stored Volume .... 0.000 0.000
Final Stored Volume ...... 0.000 0.000
Continuity Error (%) ..... 0.000
***************************
Subcatchment Runoff Summary
***************************
------------------------------------------------------------------------------------------------------------------------
------
Total Total Total Total Imperv Perv Total Total Peak
Runoff
Precip Runon Evap Infil Runoff Runoff Runoff Runoff Runoff
Coeff
Subcatchment in in in in in in in 10^6 gal CFS
------------------------------------------------------------------------------------------------------------------------
------
H1 0.98 0.00 0.00 0.96 0.02 0.00 0.02 0.04 4.11
0.019
H4 0.98 0.00 0.00 0.96 0.02 0.00 0.02 0.00 0.38
0.022
H3 0.98 0.00 0.00 0.96 0.02 0.00 0.02 0.08 8.73
0.019
H2 0.98 0.00 0.00 0.96 0.02 0.00 0.02 0.01 1.27
0.020
Mulberry - Existing SWMM - 2-yr Results
Analysis begun on: Mon Apr 5 09:34:48 2021
Analysis ended on: Mon Apr 5 09:34:48 2021
Total elapsed time: < 1 sec
Mulberry - Exist.SWMM - 100-yr Results
EPA STORM WATER MANAGEMENT MODEL - VERSION 5.1 (Build 5.1.015)
--------------------------------------------------------------
*********************************************************
NOTE: The summary statistics displayed in this report are
based on results found at every computational time step,
not just on results from each reporting time step.
*********************************************************
****************
Analysis Options
****************
Flow Units ............... CFS
Process Models:
Rainfall/Runoff ........ YES
RDII ................... NO
Snowmelt ............... NO
Groundwater ............ NO
Flow Routing ........... NO
Water Quality .......... NO
Infiltration Method ...... HORTON
Starting Date ............ 03/19/2021 00:00:00
Ending Date .............. 03/19/2021 06:00:00
Antecedent Dry Days ...... 0.0
Report Time Step ......... 00:15:00
Wet Time Step ............ 00:05:00
Dry Time Step ............ 01:00:00
************************** Volume Depth
Runoff Quantity Continuity acre-feet inches
************************** --------- -------
Total Precipitation ...... 80.263 3.669
Evaporation Loss ......... 0.000 0.000
Infiltration Loss ........ 60.314 2.757
Surface Runoff ........... 18.525 0.847
Final Storage ............ 1.457 0.067
Continuity Error (%) ..... -0.042
Mulberry - Exist.SWMM - 100-yr Results
************************** Volume Volume
Flow Routing Continuity acre-feet 10^6 gal
************************** --------- ---------
Dry Weather Inflow ....... 0.000 0.000
Wet Weather Inflow ....... 18.525 6.037
Groundwater Inflow ....... 0.000 0.000
RDII Inflow .............. 0.000 0.000
External Inflow .......... 0.000 0.000
External Outflow ......... 18.525 6.037
Flooding Loss ............ 0.000 0.000
Evaporation Loss ......... 0.000 0.000
Exfiltration Loss ........ 0.000 0.000
Initial Stored Volume .... 0.000 0.000
Final Stored Volume ...... 0.000 0.000
Continuity Error (%) ..... 0.000
***************************
Subcatchment Runoff Summary
***************************
------------------------------------------------------------------------------------------------------------------------
------
Total Total Total Total Imperv Perv Total Total Peak
Runoff
Precip Runon Evap Infil Runoff Runoff Runoff Runoff Runoff
Coeff
Subcatchment in in in in in in in 10^6 gal CFS
------------------------------------------------------------------------------------------------------------------------
------
H1 3.67 0.00 0.00 2.62 0.07 0.98 1.05 2.05 34.47
0.286
H4 3.67 0.00 0.00 1.98 0.07 1.62 1.69 0.30 8.73
0.460
H3 3.67 0.00 0.00 2.90 0.07 0.59 0.66 2.92 51.96
0.181
H2 3.67 0.00 0.00 2.38 0.07 1.22 1.29 0.77 15.53
0.352
Mulberry - Exist.SWMM - 100-yr Results
Analysis begun on: Mon Apr 5 09:35:43 2021
Analysis ended on: Mon Apr 5 09:35:43 2021
Total elapsed time: < 1 sec
Bloom Filing 1
Final Drainage Report
Proposed SWMM Model
A
D
E C
G
H
B
I
S4
S5
C1
C2
C3
C4Pond_H_Outlet
Pond_D_Outlet
Pond_E_Outlet
Pond_B_Outlet
Pond_C_Outlet
Pond_A_Outlet
6
Pond_I_Outlet C5
J2
J1
J3
J4 Peakview_Storm_Stub
CooperSlough
Lake_Canal
CooperSloughNorth
Pond_A
Pond_B
Pond_C
Pond_D
Pond_E
Pond_G
Pond_HPond_I
Fut_CommercialPond
Cityof FortCollins
CoFC_2yr
03/19/2021 00:15:00
SWMM 5.1 Page 1
***100-Year Storm***
EPA STORM WATER MANAGEMENT MODEL - VERSION 5.1 (Build 5.1.015)
--------------------------------------------------------------
*********************************************************
NOTE: The summary statistics displayed in this report are
based on results found at every computational time step,
not just on results from each reporting time step.
*********************************************************
****************
Analysis Options
****************
Flow Units ............... CFS
Process Models:
Rainfall/Runoff ........ YES
RDII ................... NO
Snowmelt ............... NO
Groundwater ............ NO
Flow Routing ........... YES
Ponding Allowed ........ NO
Water Quality .......... NO
Infiltration Method ...... HORTON
Flow Routing Method ...... KINWAVE
Starting Date ............ 03/19/2021 00:00:00
Ending Date .............. 03/20/2021 00:00:00
Antecedent Dry Days ...... 0.0
Report Time Step ......... 00:15:00
Wet Time Step ............ 00:05:00
Dry Time Step ............ 01:00:00
Routing Time Step ........ 30.00 sec
************************** Volume Depth
Runoff Quantity Continuity acre-feet inches
************************** --------- -------
Total Precipitation ...... 69.411 3.669
Evaporation Loss ......... 0.000 0.000
Infiltration Loss ........ 10.654 0.563
Surface Runoff ........... 57.664 3.048
Final Storage ............ 1.372 0.073
Continuity Error (%) ..... -0.400
************************** Volume Volume
Flow Routing Continuity acre-feet 10^6 gal
************************** --------- ---------
Dry Weather Inflow ....... 0.000 0.000
Wet Weather Inflow ....... 57.664 18.791
Groundwater Inflow ....... 0.000 0.000
RDII Inflow .............. 0.000 0.000
External Inflow .......... 0.000 0.000
External Outflow ......... 47.687 15.539
Flooding Loss ............ 0.000 0.000
Evaporation Loss ......... 0.000 0.000
Exfiltration Loss ........ 0.000 0.000
Initial Stored Volume .... 0.000 0.000
Final Stored Volume ...... 9.965 3.247
Continuity Error (%) ..... 0.020
********************************
Highest Flow Instability Indexes
********************************
All links are stable.
*************************
Routing Time Step Summary
*************************
Minimum Time Step : 30.00 sec
Average Time Step : 30.00 sec
Maximum Time Step : 30.00 sec
Percent in Steady State : 0.00
Average Iterations per Step : 1.00
Percent Not Converging : 0.00
***************************
Subcatchment Runoff Summary
***************************
------------------------------------------------------------------------------------
------------------------------------------
Total Total Total Total Imperv
Perv Total Total Peak Runoff
Precip Runon Evap Infil Runoff
Runoff Runoff Runoff Runoff Coeff
Subcatchment in in in in in
in in 10^6 gal CFS
------------------------------------------------------------------------------------
------------------------------------------
A 3.67 0.00 0.00 0.62 2.51
0.48 2.99 4.55 233.48 0.815
D 3.67 0.00 0.00 1.14 1.72
0.77 2.49 2.52 144.67 0.679
E 3.67 0.00 0.00 0.84 2.19
0.59 2.78 2.01 108.80 0.758
C 3.67 0.00 0.00 0.15 3.23
0.22 3.45 2.06 138.82 0.939
G 3.67 0.00 0.00 0.17 3.22
0.20 3.42 4.08 202.07 0.933
H 3.67 0.00 0.00 0.31 2.87
0.43 3.30 1.49 119.43 0.900
B 3.67 0.00 0.00 0.54 2.51
0.56 3.08 1.28 85.59 0.838
I 3.67 0.00 0.00 0.30 2.88
0.44 3.31 0.58 49.26 0.903
S4 3.67 0.00 0.00 0.29 2.80
0.52 3.32 0.08 8.81 0.906
S5 3.67 0.00 0.00 1.01 0.90
1.77 2.67 0.15 19.35 0.726
******************
Node Depth Summary
******************
---------------------------------------------------------------------------------
Average Maximum Maximum Time of Max Reported
Depth Depth HGL Occurrence Max Depth
Node Type Feet Feet Feet days hr:min Feet
---------------------------------------------------------------------------------
J2 JUNCTION 0.00 0.00 4935.00 0 00:00 0.00
J1 JUNCTION 0.00 0.00 4943.00 0 00:00 0.00
J3 JUNCTION 0.00 0.00 4927.00 0 00:00 0.00
J4 JUNCTION 0.00 0.00 4923.00 0 00:00 0.00
Peakview_Storm_Stub OUTFALL 0.00 0.00 4922.94 0 00:00 0.00
CooperSlough OUTFALL 0.00 0.00 4938.00 0 00:00 0.00
Lake_Canal OUTFALL 0.00 0.00 0.00 0 00:00 0.00
CooperSloughNorth OUTFALL 0.00 0.00 4940.00 0 00:00 0.00
Pond_A STORAGE 3.18 6.54 4952.04 0 02:37 6.53
Pond_B STORAGE 6.13 7.11 4949.61 0 11:55 7.11
Pond_C STORAGE 1.24 5.94 4944.44 0 02:08 5.93
Pond_D STORAGE 3.66 4.04 4948.04 0 03:37 4.04
Pond_E STORAGE 1.54 5.17 4941.17 0 02:23 5.16
Pond_G STORAGE 3.66 7.92 4936.22 0 02:40 7.92
Pond_H STORAGE 3.46 8.00 4931.00 0 02:17 8.00
Pond_I STORAGE 5.02 5.54 4928.04 0 02:41 5.54
Fut_CommercialPond STORAGE 0.90 1.87 4925.87 0 02:08 1.86
*******************
Node Inflow Summary
*******************
------------------------------------------------------------------------------------
-------------
Maximum Maximum Lateral
Total Flow
Lateral Total Time of Max Inflow
Inflow Balance
Inflow Inflow Occurrence Volume
Volume Error
Node Type CFS CFS days hr:min 10^6 gal 10^6
gal Percent
------------------------------------------------------------------------------------
-------------
J2 JUNCTION 0.00 0.73 0 03:37 0
0.441 0.000
J1 JUNCTION 0.00 0.73 0 03:37 0
0.441 0.000
J3 JUNCTION 0.00 18.11 0 02:40 0
6.15 0.000
J4 JUNCTION 0.00 22.66 0 02:33 0
7.78 0.000
Peakview_Storm_Stub OUTFALL 0.00 22.66 0 02:33 0
7.78 0.000
CooperSlough OUTFALL 0.00 21.89 0 02:18 0
7.55 0.000
Lake_Canal OUTFALL 0.00 0.35 0 02:41 0
0.21 0.000
CooperSloughNorth OUTFALL 0.00 0.00 0 00:00 0
0 0.000 gal
Pond_A STORAGE 233.48 233.48 0 00:40 4.55
4.55 0.026
Pond_B STORAGE 85.59 92.50 0 00:40 1.28
5.82 0.001
Pond_C STORAGE 138.82 138.82 0 00:40 2.06
2.06 0.012
Pond_D STORAGE 144.67 144.67 0 00:40 2.52
2.52 -0.001
Pond_E STORAGE 108.80 108.80 0 00:40 2.01
2.01 0.043
Pond_G STORAGE 210.88 214.82 0 00:40 4.16
6.16 0.015
Pond_H STORAGE 119.43 119.43 0 00:40 1.49
1.49 0.029
Pond_I STORAGE 49.26 49.26 0 00:40 0.576
0.576 -0.000
Fut_CommercialPond STORAGE 19.35 19.35 0 00:40 0.153
0.153 0.013
*********************
Node Flooding Summary
*********************
No nodes were flooded.
**********************
Storage Volume Summary
**********************
------------------------------------------------------------------------------------
--------------
Average Avg Evap Exfil Maximum Max Time
of Max Maximum
Volume Pcnt Pcnt Pcnt Volume Pcnt
Occurrence Outflow
Storage Unit 1000 ft3 Full Loss Loss 1000 ft3 Full days
hr:min CFS
------------------------------------------------------------------------------------
--------------
Pond_A 185.367 34 0 0 495.595 90 0
02:36 12.13
Pond_B 219.839 65 0 0 275.040 82 0
11:54 8.57
Pond_C 27.251 15 0 0 177.269 98 0
02:07 13.64
Pond_D 290.160 67 0 0 326.860 76 0
03:36 0.73
Pond_E 52.755 17 0 0 201.158 66 0
02:22 8.85
Pond_G 161.233 35 0 0 454.581 98 0
02:39 18.11
Pond_H 59.818 30 0 0 168.905 84 0
02:17 4.23
Pond_I 59.753 57 0 0 73.530 70 0
02:40 0.35
Fut_CommercialPond 9.018 30 0 0 18.658 62 0
02:08 0.34
***********************
Outfall Loading Summary
***********************
-----------------------------------------------------------
Flow Avg Max Total
Freq Flow Flow Volume
Outfall Node Pcnt CFS CFS 10^6 gal
-----------------------------------------------------------
Peakview_Storm_Stub 99.58 12.09 22.66 7.783
CooperSlough 99.62 11.72 21.89 7.545
Lake_Canal 99.44 0.33 0.35 0.210
CooperSloughNorth 0.00 0.00 0.00 0.000
-----------------------------------------------------------
System 74.66 24.14 44.87 15.538
********************
Link Flow Summary
********************
-----------------------------------------------------------------------------
Maximum Time of Max Maximum Max/ Max/
|Flow| Occurrence |Veloc| Full Full
Link Type CFS days hr:min ft/sec Flow Depth
-----------------------------------------------------------------------------
C1 DUMMY 0.73 0 03:37
C2 DUMMY 0.73 0 03:37
C3 DUMMY 18.11 0 02:40
C4 DUMMY 22.66 0 02:33
Pond_H_Outlet ORIFICE 4.23 0 02:17 0.00
Pond_D_Outlet ORIFICE 0.73 0 03:37 0.00
Pond_E_Outlet ORIFICE 8.85 0 02:23 0.00
Pond_B_Outlet ORIFICE 8.57 0 11:55 0.00
Pond_C_Outlet ORIFICE 13.64 0 02:08 0.00
Pond_A_Outlet ORIFICE 12.13 0 02:37 0.00
6 ORIFICE 18.11 0 02:40 0.00
Pond_I_Outlet ORIFICE 0.35 0 02:41 0.00
C5 ORIFICE 0.34 0 02:08 0.00
*************************
Conduit Surcharge Summary
*************************
No conduits were surcharged.
Analysis begun on: Tue Jul 12 16:47:44 2022
Analysis ended on: Tue Jul 12 16:47:44 2022
Total elapsed time: < 1 sec
***2-Year Storm ***
EPA STORM WATER MANAGEMENT MODEL - VERSION 5.1 (Build 5.1.015)
--------------------------------------------------------------
*********************************************************
NOTE: The summary statistics displayed in this report are
based on results found at every computational time step,
not just on results from each reporting time step.
*********************************************************
****************
Analysis Options
****************
Flow Units ............... CFS
Process Models:
Rainfall/Runoff ........ YES
RDII ................... NO
Snowmelt ............... NO
Groundwater ............ NO
Flow Routing ........... YES
Ponding Allowed ........ NO
Water Quality .......... NO
Infiltration Method ...... HORTON
Flow Routing Method ...... KINWAVE
Starting Date ............ 03/19/2021 00:00:00
Ending Date .............. 03/20/2021 00:00:00
Antecedent Dry Days ...... 0.0
Report Time Step ......... 00:15:00
Wet Time Step ............ 00:05:00
Dry Time Step ............ 01:00:00
Routing Time Step ........ 30.00 sec
************************** Volume Depth
Runoff Quantity Continuity acre-feet inches
************************** --------- -------
Total Precipitation ...... 18.508 0.978
Evaporation Loss ......... 0.000 0.000
Infiltration Loss ........ 5.189 0.274
Surface Runoff ........... 12.002 0.634
Final Storage ............ 1.371 0.072
Continuity Error (%) ..... -0.296
************************** Volume Volume
Flow Routing Continuity acre-feet 10^6 gal
************************** --------- ---------
Dry Weather Inflow ....... 0.000 0.000
Wet Weather Inflow ....... 12.002 3.911
Groundwater Inflow ....... 0.000 0.000
RDII Inflow .............. 0.000 0.000
External Inflow .......... 0.000 0.000
External Outflow ......... 11.252 3.667
Flooding Loss ............ 0.000 0.000
Evaporation Loss ......... 0.000 0.000
Exfiltration Loss ........ 0.000 0.000
Initial Stored Volume .... 0.000 0.000
Final Stored Volume ...... 0.745 0.243
Continuity Error (%) ..... 0.045
********************************
Highest Flow Instability Indexes
********************************
All links are stable.
*************************
Routing Time Step Summary
*************************
Minimum Time Step : 30.00 sec
Average Time Step : 30.00 sec
Maximum Time Step : 30.00 sec
Percent in Steady State : 0.00
Average Iterations per Step : 1.00
Percent Not Converging : 0.00
***************************
Subcatchment Runoff Summary
***************************
------------------------------------------------------------------------------------
------------------------------------------
Total Total Total Total Imperv
Perv Total Total Peak Runoff
Precip Runon Evap Infil Runoff
Runoff Runoff Runoff Runoff Coeff
Subcatchment in in in in in
in in 10^6 gal CFS
------------------------------------------------------------------------------------
------------------------------------------
A 0.98 0.00 0.00 0.29 0.62
0.00 0.62 0.94 35.83 0.631
D 0.98 0.00 0.00 0.51 0.42
0.00 0.43 0.43 23.47 0.435
E 0.98 0.00 0.00 0.38 0.54
0.00 0.54 0.39 16.91 0.551
C 0.98 0.00 0.00 0.10 0.79
0.00 0.80 0.48 22.13 0.813
G 0.98 0.00 0.00 0.10 0.79
0.00 0.79 0.94 30.65 0.809
H 0.98 0.00 0.00 0.19 0.71
0.00 0.71 0.32 21.49 0.727
B 0.98 0.00 0.00 0.29 0.62
0.00 0.62 0.26 13.91 0.634
I 0.98 0.00 0.00 0.19 0.71
0.00 0.71 0.12 9.41 0.728
S4 0.98 0.00 0.00 0.20 0.70
0.02 0.72 0.02 2.01 0.731
S5 0.98 0.00 0.00 0.69 0.22
0.05 0.27 0.02 1.59 0.276
******************
Node Depth Summary
******************
---------------------------------------------------------------------------------
Average Maximum Maximum Time of Max Reported
Depth Depth HGL Occurrence Max Depth
Node Type Feet Feet Feet days hr:min Feet
---------------------------------------------------------------------------------
J2 JUNCTION 0.00 0.00 4935.00 0 00:00 0.00
J1 JUNCTION 0.00 0.00 4943.00 0 00:00 0.00
J3 JUNCTION 0.00 0.00 4927.00 0 00:00 0.00
J4 JUNCTION 0.00 0.00 4923.00 0 00:00 0.00
Peakview_Storm_Stub OUTFALL 0.00 0.00 4922.94 0 00:00 0.00
CooperSlough OUTFALL 0.00 0.00 4938.00 0 00:00 0.00
Lake_Canal OUTFALL 0.00 0.00 0.00 0 00:00 0.00
CooperSloughNorth OUTFALL 0.00 0.00 4940.00 0 00:00 0.00
Pond_A STORAGE 0.51 2.30 4947.80 0 02:11 2.30
Pond_B STORAGE 0.97 2.81 4945.31 0 04:59 2.81
Pond_C STORAGE 0.24 2.49 4940.99 0 01:17 2.49
Pond_D STORAGE 0.86 1.04 4945.04 0 03:24 1.04
Pond_E STORAGE 0.28 1.11 4937.11 0 01:59 1.11
Pond_G STORAGE 0.63 3.09 4931.39 0 02:11 3.09
Pond_H STORAGE 0.48 2.37 4925.37 0 01:58 2.37
Pond_I STORAGE 1.83 2.77 4925.27 0 02:30 2.77
Fut_CommercialPond STORAGE 0.08 0.18 4924.18 0 02:07 0.18
*******************
Node Inflow Summary
*******************
------------------------------------------------------------------------------------
-------------
Maximum Maximum Lateral
Total Flow
Lateral Total Time of Max Inflow
Inflow Balance
Inflow Inflow Occurrence Volume
Volume Error
Node Type CFS CFS days hr:min 10^6 gal 10^6
gal Percent
------------------------------------------------------------------------------------
-------------
J2 JUNCTION 0.00 0.35 0 03:24 0
0.199 0.000
J1 JUNCTION 0.00 0.35 0 03:24 0
0.199 0.000
J3 JUNCTION 0.00 10.50 0 02:11 0
1.34 0.000
J4 JUNCTION 0.00 12.74 0 02:09 0
1.68 0.000
Peakview_Storm_Stub OUTFALL 0.00 12.74 0 02:09 0
1.68 0.000
CooperSlough OUTFALL 0.00 12.70 0 01:30 0
1.87 0.000
Lake_Canal OUTFALL 0.00 0.24 0 02:30 0
0.122 0.000
CooperSloughNorth OUTFALL 0.00 0.00 0 00:00 0
0 0.000 gal
Pond_A STORAGE 35.83 35.83 0 00:45 0.938
0.938 0.062
Pond_B STORAGE 13.91 17.84 0 00:45 0.258
1.2 0.013
Pond_C STORAGE 22.13 22.13 0 00:45 0.475
0.475 0.037
Pond_D STORAGE 23.47 23.47 0 00:40 0.429
0.429 -0.003
Pond_E STORAGE 16.91 16.91 0 00:45 0.389
0.389 0.054
Pond_G STORAGE 31.58 32.24 0 00:45 0.96
1.34 0.034
Pond_H STORAGE 21.49 21.49 0 00:40 0.321
0.321 0.063
Pond_I STORAGE 9.41 9.41 0 00:40 0.124
0.124 0.009
Fut_CommercialPond STORAGE 1.59 1.59 0 00:40 0.0155
0.0155 -0.004
*********************
Node Flooding Summary
*********************
No nodes were flooded.
**********************
Storage Volume Summary
**********************
------------------------------------------------------------------------------------
--------------
Average Avg Evap Exfil Maximum Max Time
of Max Maximum
Volume Pcnt Pcnt Pcnt Volume Pcnt
Occurrence Outflow
Storage Unit 1000 ft3 Full Loss Loss 1000 ft3 Full days
hr:min CFS
------------------------------------------------------------------------------------
--------------
Pond_A 10.713 2 0 0 70.054 13 0
02:11 6.56
Pond_B 14.721 4 0 0 53.492 16 0
04:58 5.09
Pond_C 1.142 1 0 0 19.968 11 0
01:16 8.11
Pond_D 40.931 9 0 0 52.412 12 0
03:23 0.35
Pond_E 7.172 2 0 0 30.568 10 0
01:59 3.21
Pond_G 7.853 2 0 0 61.374 13 0
02:10 10.50
Pond_H 4.595 2 0 0 28.189 14 0
01:58 2.19
Pond_I 6.901 7 0 0 14.313 14 0
02:29 0.24
Fut_CommercialPond 0.848 3 0 0 1.804 6 0
02:06 0.06
***********************
Outfall Loading Summary
***********************
-----------------------------------------------------------
Flow Avg Max Total
Freq Flow Flow Volume
Outfall Node Pcnt CFS CFS 10^6 gal
-----------------------------------------------------------
Peakview_Storm_Stub 99.55 2.60 12.74 1.676
CooperSlough 99.55 2.90 12.70 1.869
Lake_Canal 99.13 0.19 0.24 0.122
CooperSloughNorth 0.00 0.00 0.00 0.000
-----------------------------------------------------------
System 74.56 5.70 25.46 3.666
********************
Link Flow Summary
********************
-----------------------------------------------------------------------------
Maximum Time of Max Maximum Max/ Max/
|Flow| Occurrence |Veloc| Full Full
Link Type CFS days hr:min ft/sec Flow Depth
-----------------------------------------------------------------------------
C1 DUMMY 0.35 0 03:24
C2 DUMMY 0.35 0 03:24
C3 DUMMY 10.50 0 02:11
C4 DUMMY 12.74 0 02:09
Pond_H_Outlet ORIFICE 2.19 0 01:58 0.00
Pond_D_Outlet ORIFICE 0.35 0 03:24 0.00
Pond_E_Outlet ORIFICE 3.21 0 01:59 0.00
Pond_B_Outlet ORIFICE 5.09 0 04:59 0.00
Pond_C_Outlet ORIFICE 8.11 0 01:17 0.00
Pond_A_Outlet ORIFICE 6.56 0 02:11 0.00
6 ORIFICE 10.50 0 02:11 0.00
Pond_I_Outlet ORIFICE 0.24 0 02:30 0.00
C5 ORIFICE 0.06 0 02:07 0.00
*************************
Conduit Surcharge Summary
*************************
No conduits were surcharged.
Analysis begun on: Tue Jul 12 16:48:23 2022
Analysis ended on: Tue Jul 12 16:48:23 2022
Total elapsed time: < 1 sec
Bloom Filing 1
Final Drainage Report
APPENDIX F
Drainage Maps
FAIRCHILD STREETLOT 12 LOT 13 LOT 14
LOT 19
LOT 20
LOT 18
LOT 17
LOT 16
LOT 15
LOT 3
LOT 2
LOT 4
LOT 1
BLOCK 21
BLOCK 22 8''SSS
S
S
S
S
S
M
D5 D2
D3
D12
D1
D6
D4
D21
D21
acres
D1
0.59
0.73
1.37
acres
D21
0.15
0.19
2.84
acres
D2
0.59
0.74
3.29
acres
D3
0.69
0.86
1.11
acres
D5
0.62
0.77
1.13
D11
acres
D4
0.60
0.75
1.04
acres
D6
0.63
0.78
1.32
acres
D12
0.64
0.80
1.48
acres
D13
0.20
0.26
0.97
acres
D7
0.62
0.78
1.57
acres
D3.1
0.60
0.75
0.71
acres
D21.1
0.15
0.19
2.84
Know what's
before you dig.
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
SCALE: 1"=50'
0 20 5010
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF
CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION
ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER
SLOUGH FLOODPLAIN LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN THE FLOODPLAIN ARE SUBJECT TO
THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT
FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY
CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO.MATCHLINE-SEE SHEET C10.3MATCHLINE-SEE SHEET C10.1
KEYMAP
JKD
JEP
DRAINAGE PLAN
C10.0
IRRIGATION POND LIMITS
NOTES CONTINUED:
5.AN APPROVED FEMA ELEVATION CERTIFICATE COMPLETED BY A LICENSED SURVEYOR OR CIVIL
ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS REQUIRED
POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE:
IF ANY PART OF THE BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE
IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE BUILDING ENVELOPE MUST MEET THE
REQUIREMENTS OF ELEVATING TO THE RFPE.
6.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
GFAIRCHILD STREETDELOZIER ROADALLEY A
LOT 4
LOT 5
LOT 6
LOT 7
LOT 8
LOT 6 LOT 7
LOT 10LOT 11 LOT 9
LOT 8
LOT 12 LOT 11
LOT 8LOT 7
LOT 10
LOT 9
LOT 5 LOT 6 LOT 7
LOT 10LOT 11LOT 12 LOT 9
LOT 8
BLOCK 22
BLOCK 24
BLOCK 26
E5
E8
E22E9
E3E1
E2
D16
D17
D15
D10
D9
D7
D13
D8
D2D6
D8.1
D15.1
E3.1
D14
E20.1
D11
0.65
0.81
acres
D8
0.60
0.75
1.24
acres
D18.1
0.80
1.00
2.22
acres
D9
0.63
0.79
1.56
acres
D19
0.79
0.99
0.62
acres
D20
0.82
1.00
0.60
acres
D17
0.72
0.90
1.07
acres
D15
0.61
0.76
0.86
acres
D10
0.72
0.91
0.54
acres
D16
0.72
0.91
1.06
acres
E1
0.72
0.90
1.07
acres
E2
0.76
0.95
0.96 acres
E3
0.48
0.60
1.32
acres
E6
0.68
0.85
0.63
E5
acres
E8
0.21
0.27
0.35
E9 acres
E22
0.76
0.96
0.99
acres
0.62
0.78
1.57
acres
D14
0.70
0.87
0.75
acres
OS1
0.44
0.55
0.70
acres
OS2
0.41
0.51
0.68
acres
EX-1
0.41
0.51
0.68
acres
D18
0.25
0.31
0.37
acres
E20.1
0.67
0.83
1.11
acres
E3.1
0.69
0.86
0.71
acres
D15.1
0.63
0.79
0.93
acres
D8.1
0.79
0.99
0.17
acres
E11.1
0.68
0.85
0.34
acres
E25
0.78
0.98
0.74
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.MATCHLINE-SEE SHEET C10.3MATCHLINE-SEE SHEET C10.0
MATCHLINE-SEE SHEET C10.2
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010MATCHLINE-SEE SHEET C10.4JKD
JEP
DRAINAGE PLAN
C10.1
GDELOZIER ROADLOT 10
LOT 7
LOT 9
LOT 8
LOT 7
LOT 10 LOT 9
LOT 8
BLOCK 28
BLOCK 30
E27
E6
E11
E24
E10
E7
E5 E22
E23
E9
E16
E14
E12
E12.1
E11.1
E24.1
E25.1
E15
E17
acres
0.68
0.85
0.63
acres
E5
0.72
0.90
1.07
acres
OS4
0.46
0.57
0.29
acres
E7
0.74
0.92
1.03
acres
E9
0.72
0.90
1.07
acres
E10
0.74
0.93
1.03
acres
E11
0.55
0.68
0.40
acres
E12
0.79
0.99
0.44
acres
E14
0.65
0.81
0.30
acres
OS3
0.33
0.41
0.85
acres
E15
0.82
1.00
0.57
acres
OS6
0.60
0.75
0.43
acres
E17
0.65
0.81
0.59
acres
OS7
0.60
0.75
0.41
acres
E22
0.76
0.96
0.99
acres
E23
0.77
0.96
0.99
acres
E24
0.54
0.67
0.73
acres
E24.1
0.67
0.84
0.36
acres
E27
0.69
0.86
0.33
acres
FUT-G
0.90
1.00
40.3
acres
OS5
0.79
0.99
0.15
acres
E15.1
0.80
1.0
1.15
acres
E26.1
0.80
1.00
0.72
acres
E14.1
0.80
1.00
1.3
acres
E12.1
0.94
1.00
0.21
acres
E25.1
0.62
0.78
0.19
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.4MATCHLINE-SEE SHEET C10.1
MATCHLINE-SEE SHEET C10.8
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.2
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
D20
D19
D22
D24
D23
D21
acres
D11
0.65
0.81
1.15
acres
D24
0.15
0.19
3.02
acres
D22
0.15
0.19
0.24
acres
D23
0.43
0.53
0.99
acres
E19
0.80
1.00
2.72
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.6MATCHLINE-SEE SHEET C10.0MATCHLINE-SEE SHEET C10.4
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010MATCHLINE-SEE SHEET C10.1JKD
JEP
DRAINAGE PLAN
C10.3
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
G
E20E25
E28
E15.1
E17.1
E26
E19
E30
acres
E19
0.80
1.00
2.72
acres
E20
0.57
0.71
1.44
acres
E22
0.99
acres
E23
0.99
acres
E26
0.80
1.0
2.39
acres
E29
0.15
0.19
1.77
acres
E28
0.76
0.95
0.84
acres
FUT-C
0.80
1.00
22.00
acres
E30
0.77
0.97
1.04
acres
E25.1
0.62
0.78
0.19
E17.1
acres
E15.1
0.80
1.00
0.56
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022
IRRIGATION POND LIMITS
MATCHLINE-SEE SHEET C10.5MATCHLINE-SEE SHEET C10.2MATCHLINE-SEE SHEET C10.3
MATCHLINE-SEE SHEET C10.9
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010MATCHLINE-SEE SHEET C10.1JKD
JEP
DRAINAGE PLAN
C10.4
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
acres
FUT-B
0.80
1.00
15.30
acres
FUT-C
0.80
1.00
22.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.4MATCHLINE-SEE SHEET C10.6
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.5
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
acres
FUT-B
0.80
1.00
15.30
acres
FUT-A
0.80
1.00
56.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.3MATCHLINE-SEE SHEET C10.7
MATCHLINE-SEE SHEET C10.5
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.6
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
acres
FUT-A
0.80
1.00
56.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022
MATCHLINE-SEE SHEET C10.6
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.7
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
E17
acres
E17
0.65
0.81
0.59
acres
0.60
0.75
0.41
acres
FUT-G
0.90
1.00
40.3
acres
G1
0.79
0.99
1.15
acres
G2
0.79
0.99
1.15
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.9MATCHLINE-SEE SHEET C10.2
MATCHLINE-SEE SHEET C10.10
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.8
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
acres
G5
0.77
0.96
0.34
acres
G6
0.77
0.96
0.45
acres
G7
0.78
0.98
0.46
acres
G8
0.78
0.97
0.48
acres
FUT-G
0.90
1.00
40.3
acres
E17.1
0.55
0.69
0.40
acres
G6.1
0.77
0.96
0.45
acres
G7.1
0.81
1.00
0.42
G7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.8MATCHLINE-SEE SHEET C10.4
MATCHLINE-SEE SHEET C10.11
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.9
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
G3
G4
G1
G2
acres
FUT-H
0.80
1.00
33.3
acres
G4
0.81
1.00
1.16
acres
G3
0.81
1.00
1.18
acres
FUT-G
0.90
1.00
40.3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.11MATCHLINE-SEE SHEET C10.8
MATCHLINE-SEE SHEET C10.12
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.
SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.10
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
CITY OF GREELEY
G7 G8
H1 H2
acres
H1
0.77
0.97
0.55
acres
H2
0.77
0.96
0.53
acres
H3
0.80
1.00
0.92
acres
H4
0.80
0.99
1.02
acres
FUT-H
0.80
1.00
33.3
acres
G3
0.81
1.00
1.07
acres
G4
0.81
1.00
1.05
acres
G7
0.78
0.98
0.57
acres
G8
0.78
0.97
0.48
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.10MATCHLINE-SEE SHEET C10.9
MATCHLINE-SEE SHEET C10.13
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.11
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
acres
FUT-I
0.80
1.00
6.4
acres
FUT-H
0.80
1.00
33.3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.13MATCHLINE-SEE SHEET C10.10
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.
SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.12
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
CITY OF GREELEY
MODULAR
HOME
H3
H4
acres
FUT-H
0.80
1.00
33.3
acres
H3
0.80
1.00
0.92
acres
H4
0.80
0.99
1.02
-
-
-
-
-
-
-
-
-
-
-
-
-
-
STAMP
H:\Hartford Homes\CO Fort Collins HFH22 - Mulberry\0CIV\3-CD\FDP_F1\HFH022_C10.0_DRAINAGE.dwg - James Prelog - 9/14/2022Init.#Issue / DescriptionDateFINAL DEVELOPMENT PLANS BLOOM FILING ONEFORT COLLINS, COTHESE PLANS ARE AN INSTRUMENT OF SERVICE
AND ARE THE PROPERTY OF GALLOWAY, AND MAY
NOT BE DUPLICATED, DISCLOSED, OR REPRODUCED
WITHOUT THE WRITTEN CONSENT OF GALLOWAY.
COPYRIGHTS AND INFRINGEMENTS WILL BE
ENFORCED AND PROSECUTED.
COPYRIGHT
GallowayUS.com
5265 Ronald Reagan Blvd., Suite 210
Johnstown, CO 80534
970.800.3300
PRELIMINARYNOT FOR BIDDINGNOT FOR CONSTRUCTIONDate:
Drawn By:
Project No:
Checked By:
09.14.2022
HFH000022MATCHLINE-SEE SHEET C10.12MATCHLINE-SEE SHEET C10.11
DESIGN POINT
DETENTION POND BASIN BOUNDARY
(i.e., MHFD-Detention_v4.03 and/or SWMM)
SUB-BASIN BOUNDARY (i.e., Rational Method)
OVERLAND FLOW DIRECTION
(I.E., LANDSCAPING)
DIRECT FLOW DIRECTION
(I.E., PAVEMENT, CURB AND
GUTTER)
BASIN ID
2-YR RUNOFF
COEFFICIENT
BASIN AREA
(ACRES)
acres
A1
0.05
0.35
2.50
A
APPROXIMATE DETENTION POND
OVERFLOW PATH
100-YR RUNOFF
COEFFICIENT
FEMA CROSS SECTION
IRRIGATION POND LIMITS
KEYMAP
Know what's
before you dig.
SCALE: 1"=50'
0 20 5010
JKD
JEP
DRAINAGE PLAN
C10.13
NOTES:
1.PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATED, 100-YEAR COOPER SLOUGH FLOODPLAIN/FLOODWAY AND MUST
COMPLY WITH THE SAFETY REGULATIONS OF CHAPTER 10 OF CITY MUNICIPAL CODE.
2.THE DEVELOPER SHALL OBTAIN A FLOODPLAIN USE PERMIT FROM THE CITY OF FORT COLLINS AND PAY ALL APPLICABLE FLOODPLAIN USE
PERMIT FEES PRIOR TO COMMENCING ANY CONSTRUCTION ACTIVITY (BUILDING OF STRUCTURES, GRADING, FILL, DETENTION PONDS, BIKE
PATHS, PARKING LOTS, UTILITIES, LANDSCAPED AREAS, FLOOD CONTROL CHANNELS, ETC.) WITHIN THE COOPER SLOUGH FLOODPLAIN
LIMITS--. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS NOT ALLOWED IN THE FLOODWAY. ALL ACTIVITIES WITHIN
THE FLOODPLAIN ARE SUBJECT TO THE REQUIREMENTS OF CHAPTER 10 OF THE FORT COLLINS MUNICIPAL CODE.
3.CRITICAL FACILITIES ARE PROHIBITED IN THE 100-YEAR FLOODPLAIN. CRITICAL FACILITIES INCLUDE ESSENTIAL SERVICES, AT-RISK
POPULATION, HAZARDOUS MATERIALS, AND GOVERNMENT FACILITIES.
4.CONSTRUCTION OF NEW STRUCTURES, HARD SURFACE PATHS, WALKWAYS, DRIVEWAYS, WALLS, AND PARKING AREAS IS PROHIBITED IN THE
FLOODWAY UNLESS NO-RISE CONDITIONS ARE MET. ANY CONSTRUCTION ACTIVITIES IN THE REGULATORY FLOODWAY MUST ALSO INCLUDE A
NO-RISE CERTIFICATION PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN COLORADO. AN APPROVED FEMA ELEVATION CERTIFICATE
COMPLETED BY A LICENSED SURVEYOR OR CIVIL ENGINEER SHOWING THAT THE BUILDING IS CONSTRUCTED TO THE REQUIRED ELEVATION IS
REQUIRED POST-CONSTRUCTION PRIOR TO A CERTIFICATE OF OCCUPANCY (CO) BEING ISSUED. PLEASE NOTE: IF ANY PART OF THE
BUILDING IS WITHIN THE FLOODPLAIN BOUNDARY, THEN THE ENTIRE STRUCTURE IS CONSIDERED IN THE FLOODPLAIN AND THE ENTIRE
BUILDING ENVELOPE MUST MEET THE REQUIREMENTS OF ELEVATING TO THE RFPE.
5.ALL BASE FLOOD ELEVATIONS ARE BASED ON NAVD 1988 DATUM.
CITY OF GREELEY