Loading...
HomeMy WebLinkAboutFISCHER PROPERTIES - PDP220007 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANSWEST PROSPECT ROAD SOUTH SHIELDS STREET57' RIGHT-OF-WAY RESIDENTIAL LOCAL STREET (WITH PARKWAY)7' PARKING8.5' PARKWAY5' SIDEWALK9' UTILITY EASEMENT DRIVE-OVER CURB & GUTTER ℄ 4:1 MAX 30' - 15' -℄7' PARKING8.5' PARKWAY5' SIDEWALK9' UTILITY EASEMENT DRIVE-OVER CURB & GUTTER 4:1 MAX 15' -℄ 16' TRAVEL LANE C 100COVER SHEET 1 Original Field Survery: Northern Engineering Project No. 1382-001 Date: August 07,2017 AUGUST 2022 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH Project Datum: NAVD88 Benchmark PAULUS On the East edge of a double manhole Type R Inlet, 15 feet South of a concrete multi-use trail tunnel, 7 feet West of top back of curb near the Southwest corner of Shields St. and Elizabeth St. Elevation: 5025.82 Benchmark CSU2 The mark is a standard brass Larimer County geodetic control disk set in 2002, in the campus of Colorado State University approx. 240.8 feet South from the center line of North Drive, 46.6 feet Northeast from the edge of CSU Lagoon, 33 feet Southwest from the center of the delivery road to the University Club and 1.1 feet Southwest from the edge of the sidewalk. Elevation: 5006.29 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (Prior City of Fort Collins datum) for their vertical datums. If NGVD29 unadjusted datum (Prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 = NAVD88 - 3.17' Basis of Bearings The East line of the Northeast Quarter of the Southeast Quarter of Section 15, Township 7 North, Range 69 West of the 6th P.M. as bearing South 00° 29' 40" West (assumed). PROJECT BENCHMARKS: FISCHER PROPERTIES PROJECT TEAM: OWNER/APPLICANT SHEET INDEX A TRACT OF LAND LOCATED IN THE SOUTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO FIELD SURVEY BY: TYPICAL SECTIONS 1 C 100 COVER SHEET 2 C 101 GENERAL & CONSTRUCTION NOTES 3 C 200 EXISTING CONDITIONS & DEMOLITION PLAN 4 C 300 CIVIL SITE PLAN UTILITY SHEETS 5 C 400 OVERALL UTILITY PLAN 6-7 C 401-C 402 UTILITY PLAN GRADING SHEETS 8 C 500 OVERALL GRADING PLAN 9-10 C 501-C 502 GRADING PLAN ROADWAY SHEETS 11 C 600 LAKEWOOD DRIVE PLAN & PROFILE 12 C 601 WESTWARD DRIVE RIGHT FLOWLINE - PLAN & PROFILE 13 C 602 DEL MAR STREET RIGHT FLOWLINE - PLAN & PROFILE 14 C 603 DEL MAR STREET & LAKEWOOD DRIVE INTERSECTION DETAIL DRAINAGE SHEETS 15 C 700 HISTORIC DRAINAGE EXHIBIT 16 C 701 DRAINAGE EXHIBIT UTILITY PLANS FOR CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 APPROVED: City Engineer:Approved Sheets Date Water & Wastewater Utility Approved Sheets Date Stormwater Utility Approved Sheets Date Park Planning and Development Approved Sheets Date Traffic Operations Approved Sheets Date Environmental Planner Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: PROJECT LOCATION Ripley Design, Inc. Russ Lee, President 419 Canyon Avenue, Suite 200 Fort Collins, CO. 80521 (970) 224-5828 Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N PLANNER/ LANDSCAPE ARCHITECT SITE ENGINEER SURVEYOR ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ Erik Fischer 125 S. Howes Street, Suite 900 Fort Collins, CO 80521 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 Additional Survery: Northern Engineering Project No. 1382-002 Date: March 23, 2022 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R A. GENERAL NOTES 1.All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2.All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3.These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4.The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5.All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6.The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7.The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8.The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9.If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10.The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11.No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12.The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14.A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15.The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18.The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19.All recommendations of the Preliminary Drainage Report for Fischer Properties by Northern Engineering, dated August 24, 2022 by Northern Engineering shall be followed and implemented. 20.Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21.The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22.No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23.The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24.The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25.The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26.All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27.Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28.All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29.Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30.The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31.The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32.Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33.The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34.There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35.The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36.Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37.The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38.If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39.The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40.The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: Project Datum: NAVD88 Benchmark PAULUS On the East edge of a double manhole Type R Inlet, 15 feet South of a concrete multi-use trail tunnel, 7 feet West of top back of curb near the Southwest corner of Shields St. and Elizabeth St. Elevation: 5025.82 Benchmark CSU2 The mark is a standard brass Larimer County geodetic control disk set in 2002, in the campus of Colorado State University approx. 240.8 feet South from the center line of North Drive, 46.6 feet Northeast from the edge of CSU Lagoon, 33 feet Southwest from the center of the delivery road to the University Club and 1.1 feet Southwest from the edge of the sidewalk. Elevation: 5006.29 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 unadjusted datum (Prior City of Fort Collins datum) for their vertical datums. If NGVD29 unadjusted datum (Prior City of Fort Collins datum) is required for any purpose, the following equation should be used: NGVD29 = NAVD88 - 3.17' Basis of Bearings The East line of the Northeast Quarter of the Southeast Quarter of Section 15, Township 7 North, Range 69 West of the 6th P.M. as bearing South 00° 29' 40" West (assumed). 41.All stationing is based on centerline of roadways unless otherwise noted. 42.Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44.Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45.Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46.After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47.The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48.Approved Variances are listed as follows: 1) N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1.The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2.There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3.All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4.At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5.Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6.All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7.In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a.Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b.Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c.Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8.When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9.The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10.All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11.No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12.The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13.City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14.A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15.Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16.For additional information see separate Stormwater Management Plan / Erosion Control Report for Fischer Properties. B. Street Improvement Notes 1.All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2.A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3.Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4.Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5.Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6.When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7.All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8.The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9.Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1.All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2.All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3.All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4.All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5.All lane lines for concrete pavement should be epoxy paint. 6.Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7.Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8.Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9.All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10.All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11.A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12.The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13.Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14.Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15.Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1.The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2.All recommendations of the Preliminary Drainage Report for Fischer Properties by Northern Engineering, dated August 24, 2022 by Northern Engineering shall be followed and implemented. 3.Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1.All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2.The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3.Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4.HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City Water Detail 11A. INFILL AND REDEVELOPMENT NOTE A.Despite everyone's best efforts, it is impossible to fully display subsurface information prior to excavation. This is especially true in areas of infill and redevelopment. Unknown subsurface conditions can have cost and schedule implications. Prior to finalizing contract terms, it is strongly recommended that the Owner and General Contractor have a candid discussion to formulate a strategy for dealing with such circumstances when they arise. The process and procures should be in place prior to excavation. Allowances and contingencies can address the cost implications, but additional measures are required to deal with scheduling and factors impacting sequence of work. The Architect, Engineer(s), and Construction Surveyor should be made aware of the protocol for dealing with such unknown subsurface conditions prior to starting work. C 101CONSTRUCTION NOTES GENERAL &2 /////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XWS OW S OWSOWSOWS O W S OWS OELEC W D D D VAULT ELEC M C VAULT ELEC M M D D D C EC C CCCC VAULT ELEC C C C C HY DV.P. V.P.STS S S S S S X 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS SS SS15" SSSTSTSTSTSTSTSTSTSTSTSTSTS T 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSSTGW XX X X X X X X X XXXXX XXXXXXE W W W W W CTVCTVW CTV CTVCTVCTVCTVGGGCTV CTV G G G G G GGGG E EEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV X X X X X X X X X X XX X X X X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV XXXXXX X X X X X X X X X G G GG G CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRR W VAULT CABLE C VAULT CABLE OHU OHU OHU OHU OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHUXXXXXXXXXXGGE E E 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W CTV CTV CTV CTV CTV CTV CTV CTV CTV 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SSW W W W W WWWWWWWWWWWWW W SSSSSSSSSSSSSSSSSSSSSSSSWEWE E E E E E G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOE EEWWGGGGGGGGW W W W FOEFOG G G E E E E FO FO FO E W WWWWFO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E EES W ELEC WCS W W ELEC VAULT TELE ELEC W W M M M S W F.O. F.O. D D C SCS CABLE FO FO FOEXISTING FENCE TO BE REMOVED (TYP.) EXISTING GATE TO BE REMOVED (TYP.) EXISTING GATE TO BE REMOVED (TYP.) EXISTING TREE TO BE REMOVED (TYP.) EXISTING BUILDINGS TO BE REMOVED (TYP.) EXISTING SHRUB TO BE REMOVED (TYP.) ±400 LF EXISTING HOLLYWOOD CURB, GUTTER, & ATTACHED SIDEWALK TO BE REMOVED EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN EXISTING WATER SPIGOT TO BE REMOVED (TYP.) EXISTING GRAVEL DRIVE TO BE REMOVED (TYP.) EXISTING UTILITY POLE TO BE REMOVED (TYP.) EXISTING NATURAL GAS LINE TO BE REMOVED EXISTING WATER SERVICE TO BE REMOVED (TYP.) EXISTING NATURAL GAS LINE TO BE REMOVED ±279 LF EXISTING HOLLYWOOD CURB, GUTTER, & ATTACHED SIDEWALK TO BE REMOVED SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE EXISTING DRIVEWAY APPROACHES TO BE REMOVED EXISTING UTILITY EASEMENT TO BE VACATED (TYP.) EXISTING UTILITY EASEMENT TO BE VACATED (TYP.) EXISTING LOT LINE TO BE VACATED (TYP.) ±522 LF EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING 8" CLAY SANITARY SEWER TO REMAIN EXISTING 6" CAST IRON WATER MAIN TO REMAIN EXISTING 6" CAST IRON WATER MAIN TO REMAIN EXISTING 15" PVC SANITARY SEWER TO REMAIN EXISTING 21" RCP STORM DRAIN TO REMAIN EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING 10" CLAY SANITARY SEWER EXISTING ELECTRIC EXISTING 6" CAST IRON WATER MAIN TO REMAIN EXISTING GAS LINE EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING STORM DRAIN EXISTING FENCE EXISTING 24" RCP STORM DRAIN TO REMAIN EXISTING 18" RCP STORM DRAIN TO REMAIN EXISTING 40' FL-FL EXISTING 60' ROW EXISTING ±64' FL-FL PROPOSED SAWCUT (TYP.) EXISTING 60' ROW TO BE VACATED PROPOSED SAWCUT (TYP.) EXISTING 6" CAST IRON WATER MAIN TO REMAIN EXISTING 8" CLAY SANITARY SEWER TO REMAIN EXISTING FIRE HYDRANT TO BE REMOVED EXISTING ±39' FL-FL EXISTING 60' ROW EXISTING SECTION LINE EXISTING 3' ATTACHED SIDEWALK EXISTING HOLLYWOOD CURB, GUTTER, & WALK EXISTING 3' ATTACHED SIDEWALK EXISTING 6' ATTACHED SIDEWALK40' FL-FLOWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. LOT 17LOT 18LOT 19LOT 20LOT 21 LOT 39LOT 38LOT 37LOT 36LOT 34 LOT 35 LOT 40LOT 41LOT 42LOT 43 LOT 45 LOT 44 LOT 63LOT 62LOT 61LOT 60LOT 58 LOT 59 EXISTING WATER SERVICE TO BE REMOVED PROTECT EXISTING TREE IN PLACE PROTECT CRITICAL ROOT ZONE AS MUCH AS POSSIBLE. EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN (TYP.) EXISTING WATER SERVICE TO BE REMOVED AND ABANDONED AT MAIN (TYP.) EXISTING SANITARY SEWER MANHOLE RIM=5038.44 INV IN=5030.84 (W) INV OUT=5030.69 (S) EXISTING SANITARY SEWER MANHOLE RIM=5031.59 INV IN=5124.39 (E) INV IN=5124.4 (S) INV OUT=5124.39 (E) EXISTING SANITARY SEWER MANHOLE RIM=5030.94 INV IN=5023.34 (N) INV OUT=5023.31 (S) EXISTING SANITARY SEWER MANHOLE RIM=5035.50 INV IN=5022.45 (N) INV IN=5026.44 (W) DROP INV OUT=5022.29 (E) EXISTING ±50' HALF ROW CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 EXISTING ELECTRIC E LEGEND: G T EXISTING STORM SEWER ST EXISTING TELEPHONE EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: NOTES: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR EXISTING TREES (TO BE REMOVED) EXISTING CABLE CTV EXISTING FIBER OPTIC FO 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3.CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. 4.ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6.ALL WATER AND SEWER SERVICES SHALL BE REMOVED AND ABANDONED AT THE CITY MAIN, PER FORT COLLINS UTILITIES STANDARDS. EXISTING OVERHEAD UTILITY OHE NORTHERN ENGINEERING PROJECT NO. 1382-001 DATE: AUGUST 07,2017 EXISTING SECTION LINE NORTHERN ENGINEERING PROJECT NO. 1382-002 DATE: MARCH 23, 2022 C 200DEMOLITION PLAN EXISTING CONDITIONS &3 X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XCC C C C C C C C C C C C C CCCCCCCCCCCCCCCCCC CCCCCCCC/ / / / / / / /C5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 5' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 6' SIDEWALKSPRING F I E L D D R I V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK5' SIDEWALK18' (TYP.) 8.5' (TYP.) 30' FL-FL57' ROW 12.5' (TYP.) 19' 18' (TYP.) 18' (TYP.) 8.5' (TYP.) 18' (TYP.) 8' (TYP.) 18' 8.5' 7.5' 8' 9' 9' 18' (TYP.) 8.5' (TYP.) 15' (TYP.) 15' (TYP.) 8' (TYP.) 15' (TYP.) 15' (TYP.) 8' (TYP.) 8' (TYP.) 21' (TYP.) 26' FL-FL 24' FL-FL 26' FL-FL 26' FL-FL 24'26' 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 7 LOT 6 LOT 9 LOT 8 LOT 3 LOT 4 LOT 1 LOT 2 LOT 5 TRACT B AE,DE,UE DRAINAGE EASEMENT PROPOSED 2' SIDEWALK CULVERT PROPOSED 2' CONCRETE PAN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND TRANSITION TO DRIVE-OVER CURB & GUTTER 18" VERTICAL CURB & GUTTER 31" DRIVE-OVER CURB & GUTTER 18" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER PROPOSED DETENTION POND DRIVEWAY APPROACHES TO BE REPLACED WITH VERTICAL CURB & GUTTER PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN 31" DRIVE-OVER CURB & GUTTER PROPOSED SAWCUT (TYP.) EXISTING 6" CURB w/ 5' CONCRETE GUTTER PROPOSED 2' CONCRETE PAN 31" DRIVE-OVER CURB & GUTTER PROPOSED TRASH ENCLOSURE DRAINAGE EASEMENT OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. BIKE BARN (RE: LANDSCAPE) BIKE BARN (RE: LANDSCAPE) 6' SIDEWALK 6' SIDEWALK 6' SIDEWALK6' SIDEWALK19' (TYP.) TRACT A AE,DE,UE 5' UTILITY EASEMENT 5' UTILITY EASEMENT9' UTILITY EASEMENT9' UTILITY EASEMENT15' UTILITYEASEMENTSOUTH SHIELDS STREETCALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE / / / / / / / /PROPOSED EDGE OF PAVEMENT DRIVE AISLE ASPHALT PAVING PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: PARKING STALL ASPHALT PAVING PRIVATE CONCRETE PAVING HEAVY DUTY ASPHALT PAVING PUBLIC CONCRETE FLATWORK PRIVATE CONCRETE FLATWORK ASPHALT PATCH RAIN GARDEN BIOMEDIA AREA C 300CIVIL SITE PLAN 4 X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D VAULT ELEC C VAULT ELEC D D D C EC C CCCC VAULT ELEC C C C C STS S S S S S 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS SS SS15" SSSTSTSTSTSTSTSTSTSTSTSTSTS T 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 10" SS 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSSTCTVCTVCTV CTVCTVCTVCTVGGGCTV CTV GGGGEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV VAULT CABLE C VAULT CABLE OHU OHU OHU OHU OHU OHU OHU OHU OHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W CTV CTV CTV CTV CTV CTV CTV CTV CTV 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SSWWWWWWWWWWWWW W SSSSSSSSSSSSSSSSSSSSSSSSWEWE E E E E E G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOE EEWWGGGGGGGGW W W W FOEFOG G G E E E E FO FO FO E W WWWWFO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E EES W ELEC WCS W ELEC VAULT TELE ELEC W W M M M S W F.O. F.O. D D C SCS CABLE FO FO FOFGGGGGGGGT T G G G G E E E E E E E E EEEEEEEEEEE E EEEES FDC EEEEEWNYLOPLASTDO NOT P O L L U T E DRAINS T O WATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UD NYLOPLASTDO NOT P O L L U T E DRAINS TOWATERWA Y S DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOP L AS T DO NOT PO L L UT EDRAINS TO WATERW A YS DO NOT PO L L U TE D RA I N S TO W A TE R W A YS NYLOPLAS T D U C T I LE I R ON / / / / / / / /PROPOSED 8" PVC SANITARY SEWER PROPOSED 8" WATER MAIN CONNECT TO EXISTING 4" WATER MAIN CONNECT TO EXISTING 6" WATER MAIN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 3 4" UNDERDRAIN 30' SANITARY SEWER EASEMENT PROPOSED STORM DRAIN PROPOSED STORM DRAINPROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 PROPOSED FIRE HYDRANT PROPOSED SIDEWALK CULVERT PROPOSED SANITARY SERVICE PROPOSED FIRE SERVICE PROPOSED WATER METER PROPOSED FIRE HYDRANT CONNECT TO EXISTING STORM DRAIN 9' DRAINAGE & UTILITY EASEMENT 5' UTILITY EASEMENT SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW5' SIDEWALK5' SIDEWALK9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED FIRE HYDRANT EXISTING ELECTRIC LINE EXISTING CABLE TV LINE PROPOSED 2' SIDEWALK CULVERT (TYP.) PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN DETENTION POND 1 CONNECT TO REPLACED 8" SANITARY SEWER LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 BLOCK 1 BLOCK 1 TRACT B AE,DE,UE EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING 8" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER EXISTING 6" CAST IRON WATER MAIN EXISTING 15" PVC SANITARY SEWER EXISTING 21" RCP STORM DRAIN EXISTING GAS LINE EXISTING 10" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER MAIN EXISTING GAS LINE EXISTING ELECTRIC LINE EXISTING 24" RCP STORM DRAIN EXISTING 18" RCP STORM DRAIN EXISTING 4" CAST IRON WATER MAIN EXISTING 8" CLAY SANITARY SEWER EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE PROPOSED 2' CONCRETE PAN PROPOSED ROOF DRAIN (TYP.) OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. APPROXIMATE LOCATION CONNECT TO EXISTING 3-PHASE POWER PROPOSED TRANSFORMER PROPOSED TRANSFORMER CONNECT TO EXISTING STORM DRAIN 6' SIDEWALK 6' SIDEWALK6' SIDEWALK30' SANITARY SEWER EASEMENT TRACT A AE,DE,UE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 C 400OVERALL UTILITY PLAN 5 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 X X X X X X X XXX X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXX CCCC VAULT ELEC C C C C CTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHUOHUOHUOHU OHU 8" SS 8" SS 8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SS8" SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSE E EEEEWWWWWGGGGGGGGGGGGGGGGGGW W W WWWWWWWWWFO FO FO S S / / / / / / / // / / / / / / // / / / / / / /GGGGGGGGGGEEEEEEEEEUDUDUDUDUDUDUDUDPROPOSED 8" PVC SANITARY SEWER PROPOSED 8" PVC WATER MAIN CONNECT TO EXISTING 4" WATER MAIN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 1 PROPOSED UNDERDRAIN 30' SANITARY SEWER EASEMENT CONNECT TO REPLACED 8" SANITARY SEWER PROPOSED FIRE HYDRANT 5' UTILITY EASEMENT 5' UTILITY EASEMENT DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW PROPOSED FIRE HYDRANT LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT RAINGARDEN ABLOCK 1 BLOCK 1 PROPOSED 2' CONCRETE PAN EXISTING 4" CAST IRON WATER LINE RAIN GARDEN BIOMEDIA AREA 3' DRAINAGE EASEMENT (TYP.) PROPOSED 2' SIDEWALK CULVERT PROPOSED 2' SIDEWALK CULVERT PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE EXISTING ELECTRIC LINE EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING GAS LINE EXISTING 4" CAST IRON WATER MAIN EXISTING 8" CLAY SANITARY SEWER EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. ±39' FL-FL 60' ROW 5' SLOPE EASEMENT PROPOSED 2' SIDEWALK CULVERT TRACT A AE,DE,UE 30' SANITARY SEWER EASEMENT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 402C 401UTILITY PLAN 6 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 X X X X XXXXXX X X XXXXXXXXXXXXXXD D VAULT ELEC C VAULT ELEC D D C EC C C C S S8" SS 8" SS 8" SS SS SS STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T 15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SS15" SSCTVCTVCTVCTVCTVCTV CTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV GGGGGGGEEEEEEEEEEEEEEECTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTVCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTVVAULT CABLE C VAULT CABLE OHU OHU OHU OHUOHUOHUOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU E E E E E E E E 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV C T V CTV CTV CTV CTV CTV C T V W W WSSSSSS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSWWWEEWWE E E E E E E E E E E G G G G G G G G G G G G G G G G G FOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOFOCTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E E E E E E EEES ELEC WCS ELEC VAULT TELE ELEC W W M M M C SCS FO FO FO FO FOFOFGGGGGGGGGGGGGGG G G GTT GG G G G G G G G E E E E E E E E E E E E E E E E E EEEEEEEEEEEEEEEEEEEE E E E E EEEEEE E E ESFDC EEEEEEEEEEWNYLOPLASTDO NOT POLLUTEDRAINS TOWATERWAYSDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUD UD UD UD UD UD UD UD UD UD UD NYLOPLASTDO NO T P O L L U T E DRAI N S T O WATE R W A Y S DO NOT P O L L U T E D R A I N S T O W A T E R W A Y S NYLOPL A S T D U C T I L E I R O NUDUDUDUDUD DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOPLAS TDO NO T P OL LU TEDRAIN S TOWATER WA YS DO NO T P OL L UT E D RA I NS TO W A TE RW AY S NYLO P LA ST DU C TI L E I RO N CONNECT TO EXISTING 6" WATER MAIN RAIN GARDEN BIOMEDIA AREA PROPOSED DETENTION POND 1 PROPOSED DETENTION POND 1 30' SANITARY SEWER EASEMENT CONNECT TO REPLACED 8" SANITARY SEWER PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH CHAMBERS PROPOSED SANITARY SERVICE PROPOSED FIRE SERVICE PROPOSED WATER METER PROPOSED FIRE HYDRANT CONNECT TO EXISTING STORM DRAIN SOUTH SHIELDS STREETWESTWARD DRIVE 6' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALKLOT 1 PROPOSED 2' SIDEWALK CULVERT PROPOSED STORM DRAIN PROPOSED UNDERDRAIN PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE DRAINAGE EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT EXISTING 8" CLAY SANITARY SEWER TO BE REPLACED IN PLACE EXISTING 8" CLAY SANITARY SEWER EXISTING 6" CAST IRON WATER EXISTING 15" PVC SANITARY SEWER EXISTING 21" RCP STORM DRAIN EXISTING GAS LINEEXISTING ELECTRIC LINE EXISTING 18" RCP STORM DRAIN OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. 26' EMERGENCY ACCESS EASEMENT PROPOSED ROOF DRAIN ±37' FL-FL 60' ROW PROPOSED TRANSFORMER PROPOSED TRANSFORMER APPROXIMATE LOCATION CONNECTION TO 3-PHASE POWER AT CORNER OF SPRINGFIELD DRIVE & SHIELDS STREET PROPOSED FDC PROPOSED 2' SIDEWALK CULVERT DRAINAGE EASEMENT DRAIN BASIN w/ 100-YR WEIR DRAIN BASIN w/ WQ WEIR CONNECT TO EXISTING STORM DRAIN PROPOSED CULVERT PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN ISOLATOR ROWS 30' SANITARY SEWER EASEMENT PROPOSED UNDERGROUND DETENTION POND 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 MATCH LINE - SEE SHEET C 401 C 402UTILITY PLAN 7 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.ALL WATER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS, LATEST EDITION, EXCEPT THAT NO MECHANICAL JOINT RESTRAINTS ARE REQUIRED BETWEEN FITTINGS UNLESS SPECIFICALLY SHOWN ON THE PLAN OR AS REQUIRED FOR ABNORMAL DEFLECTIONS. 3.ALL SEWER CONSTRUCTION SHALL BE PER CITY OF FORT COLLINS UTILITY SPECIFICATIONS SANITARY SEWER DESIGN TECHNICAL CRITERIA MANUAL, LATEST EDITION. 4.ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5.ALL WATERLINES SHALL HAVE A 4.5'-5' FROM FINISHED GRADE TO TOP OF PIPE. 6.UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 8.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 10.ALL MANHOLE RIM ELEVATIONS (EXISTING & PROPOSED) ARE TO BE ADJUSTED TO 14" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 11.ALL WATER SERVICES SHALL BE 3 4" UNLESS OTHERWISE NOTED. EXISTING LOT LINE EASEMENT LINE SPROPOSED SEWER SERVICE WPROPOSED WATER SERVICE EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: G T EXISTING STORM SEWER EXISTING TELEPHONE EXISTING GAS EXISTING SANITARY SEWER PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPERTY BOUNDARY EXISTING TELEPHONE PEDESTAL PROPOSED STREET LIGHT W SS PROPOSED LOT LINE PROPOSED ROW EXISTING ROW EXISTING CABLE CTV RAIN GARDEN BIOMEDIA AREA C 402 C 401 NYLOPLASTDO NOT P O L L U T E DRAINS T O WATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UD NYLOPLASTDO NOT P O L L U T E DRAINS TOWATERWA Y S DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOP L AS T DO NOT PO L L UT EDRAINS TO WATERW A YS DO NOT PO L L U TE D RA I N S TO W A TE R W A YS NYLOPLAS T D U C T I LE I R ON X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D D D D STSTSTSTSTSTSTSTSTSTSTSTSTS T STD D / / / / / / / /SOUTH SHIELDS STREETSPRIN G F I E L D D R I V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 6' SIDEWALK6' SIDEWALK6' SIDEWALK 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW RAIN GARDEN BIOMEDIA AREA DETENTION POND 3 DETENTION POND 1 5' SIDEWALK5' SIDEWALKPROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED AREA DRAIN PROPOSED STORM INLET PROPOSED CURB INLET 9' UTILITY EASEMENT 9' UTILITY EASEMENT LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 TRACT B AE,DE,UE EXISTING 18" STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' SIDEWALK CULVERT PROPOSED 2' SIDEWALK CULVERT PROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 FFE=32.92 OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. ± 37' FL-FL EXISTING 60' ROW EXISTING ±64' FL-FL ±40' FL-FL 60' ROW 40' FL-FLEXISTING ±50' HALF ROW PROPOSED MULTI-FAMILY BUILDING PROPOSED CURB INLET PROPOSED CURB INLET NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 500OVERALL GRADING PLAN 8 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE C 502 C 501 X X X X X X X XXX X X X X X X X X XXXXXXXXXXXXXXXXXXXXXXXXXXX/ / / / / / / // / / / / / / // / / / / / / /UDUDUDUDUDUDUDUD3 2 . 4 036.6130.28 31.6630.8930.9031.0931.2131.673 2 . 4 231.6731.79 31.6431.800.6% 3.2%2.5%0.5%0.2%2.9%DEL MAR STREETLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 5' SIDEWALK1.3% LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED DETENTION POND 3 RAINGARDEN A(35.22)(3 4 . 3 9 )(33.70)32.90 33.9134.30 35.63 35.6434.3033.91 32.92 (35.24)(35.85)(3 6 . 5 9 )(37.66)(3 8 . 8 5 ) 31.26 31.23 31.43 BLOCK 1 BLOCK 1 RAIN GARDEN BIOMEDIA AREA PROPOSED 2' CONCRETE PAN 30' FL-FL57' ROW 30' SANITARY SEWER EASEMENT 5' UTILITY EASEMENT 5' UTILITY EASEMENT 3' DRAINAGE EASEMENT (TYP.) PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE PROPOSED 2' SIDEWALK CULVERT 6" RIBBON CURB RAIN GARDEN BIOMEDIA AREA(36.33)(3 5 . 7 8 ) (4 0 . 8 2 ) (35 . 0 1 )(33.39)(33.90)31.9331.1331.603 0 . 9 7 31.4631.3931.2431.2931.45(33.35)(36.90)37.0138.1637.5936.0735.593 3 . 3 0 33.9232.54 32.44 32.4733.3033.9338.0039. 0 9 30. 2 8 30.28 3 1 . 1 7 26.8326.9927.2732.1932.1631.56 30.2830.3130.31 30.3131.8530.3130.31RAINGARDEN A31.12OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. ±39' FL-FL 60' ROW 31. 0 8 32.3226.98 3 2 . 1 7 32.59 31.68 27.380.5%0.5% 26.88 0.6% PROPOSED 2' SIDEWALK CULVERT 1.0%3.5%0.5%0.5%0.5%2.0% 2.0%0.5%2.0%2.1%1.6%1.0%30.3131.7231.6231.9032.0032.0732.0331. 4 131.5031.88 3 1 . 7 9 31.71 31.76 2.2%0.5% 0.5 % 2.6%0.6%31.500.5%31.59PROPOSED 2' SIDEWALK CULVERT 31.1131.02 30.9832.1731.96 32.04 30.8731.21 31. 3 1 30. 2 8 30.2831.3131.16 27.51 27.51 32.80 32.76 33.26 29.20 28.64 27.59 27.7927.17 34.14 35.17 35.33 34.19 34.12 34.0433.75 27.62 27.15 26.85 27.65 SLOPE EASEMENT 31.813 2 . 0 132.1032.0032.0231.9731.853 1 . 2 3 2.7%2.0%2.6%2.8%2.1% 2.1% 1.9%2.1%2.3%2.3% 2.0% 2.2%2. 8% 2.5%4.8%2.8 %5.6%4 :1 6:1 4:16 : 15:15:1 4:1 4:1 4:1 4:1 4:1 4:1 4:18:16:11.0%6' SI D E W A L K 6' SIDEWALK TRACT A AE,DE,UE TRACT A AE,DE,UE 0.8% 0 . 6%0.5%2.4%2.1%1.1%3 1 . 4 6 PROPOSED SIDEWALK CULVERT NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R MATCH LINE - SEE SHEET C 502C 501GRADING PLAN 9 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA C 502 C 501 X X X X XXXXXX X X XXXXXXXXXXXXXXD D D D STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTS T S T FDC NYLOPLASTDO NOT POLLUTEDRAINS TOWATERWAYSDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUD UD UD UD UD UD UD UD UD UD UD NYLOPLASTDO NO T P O L L U T E DRAI N S T O WATE R W A Y S DO NOT P O L L U T E D R A I N S T O W A T E R W A Y S NYLOPL A S T D U C T I L E I R O NUDUDUDUDUD DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOPLAS TDO NO T P OL LU TEDRAIN S TOWATER WA YS DO NO T P OL L UT E D RA I NS TO W A TE RW AY S NYLO P LA ST DU C TI L E I RO N 31.6630.8930.9031.0931.2131.6731.4731.0031.39 31.06 31.1731.633 2 . 4 231.6731.79 31.6431.8031.4928.210.6% 3.2%2.5%0.6%2.9%0.5%0.5%0.5%0.2%1.0%2.1%2.4%2.1%2.9%SOUTH SHIELDS STREETWESTWARD DRIVE 5' SIDEWALK6' SIDEWALK6' SIDEWALK 7' SIDEWALK 5' SIDEWALK 6' SIDEWALK27.87(27.62)(31.13)30.350.8%1.4%1.3% 0.6%0.5%PROPOSED DETENTION POND 1 3 1 . 0 4 31.04 31.10 31.1030.55 30.55 30.80 30.85 31.26 31.23 31.43 31.23 31.23 31.51 31.48 30. 9 031.763 0 . 9 6 3 0 . 9 8 TRACT B AE,DE,UERAIN GARDEN BIOMEDIA AREA PROPOSED 4' CONCRETE PAN PROPOSED 2' CONCRETE PAN PROPOSED STORM INLET PROPOSED CURB INLETPROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORMTECH CHAMBERS UNDERGROUND DETENTION POND 2 DRAINAGE EASEMENT 26' EMERGENCY ACCESS EASEMENT 26' EMERGENCY ACCESS EASEMENT 30' SANITARY SEWER EASEMENT 26' EMERGENCY ACCESS EASEMENT PROPOSED 2' CONCRETE PAN PROPOSED POND OUTLET STRUCTURE RAIN GARDEN BIOMEDIA AREA PROPOSED POND OUTLET STRUCTURE 26' EMERGENCY ACCESS EASEMENT CONNECT TO EXISTING STORM DRAIN EXISTING 21" RCP STORM DRAIN EXISTING 18" RCP STORM DRAIN PROPOSED TRASH ENCLOSURE FFE=32.92 26' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT (33.39)(3 3 . 9 0 )(30.65)(30.53)27.71 27.90 28.09 (28.12)(28.60)(29.00)(29.50)(30.43)30.74 3 0 . 7 330.6831.3031.4231.9331.1331.603 0 . 9 7 31.4631.2531.3931.2431.2931.4531. 2 431.4131.6431.8531.9931.6530.89 30. 9 8 31.37 32.14(3 3 . 3 5 ) 30.28 3 1 . 1 7 26.8332.1932.1630.66 30.6331.56 30.2830.3131.8530.3110.3%0.5%29.7632.7332.3732.9231.040.5%OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. ±37' FL-FL 60' ROW PROPOSED ROOF DRAIN (TYP.) BIKE BARN (RE: LANDSCAPE) BIKE BARN (RE: LANDSCAPE)31.4031.6529.8131.8631.8431.4431.3830.7632.2532.25 32.2532.2532.0532.2531.5231.0629.1629.4330.5931.3431.9232.1227.520.5%31.7532.0831.2531.322 7 . 7 030.4730.9430.4530.6431.2332.2532.0432.9231.7932.2231.5232.2531.4132.2531.2832.2431.3432.0331.5631.1431.0831.1231. 0 8 31.05 31. 4 0 31. 3 1 31.1031.783 1 . 9 731.9231.7232.9232.2531.8331.0031.6431.4631.1231.9631.7631.6431.3531.4631.4831. 5 331.2731.3232.3226.98 32.1732.59 31.68 27.3826.88 0.6% PROPOSED 2' SIDEWALK CULVERT 1.0%3.5%0.5%0.5%0.5%2.0% 2.0%0.5%2.0%2.1%1.6%1.0%30.3131.7231.6231.9032.0032.0732.0331. 4 131.5031.88 3 1 . 7 9 31.71 31.76 2.2%0.5% 0.5 % 2.6%0.6%31.50 30.26 30.83 0.8%0.5%31.0331.3630.62 30.700.5%PROPOSED 2' SIDEWALK CULVERT 31.1130.6330.3630.2031.1631.6631.1631.3431.0230.10 29.1129.1127.9928.2328. 2 3 28. 4 8 28.4830.9130.91 2 8 . 2 4 28.0830.8631.0530.7731.0530.8429.5228.8230.6727.97 28. 1 4 31.3430.9130.590.8%30.9130.7531.1331.1331.4431.3631.89 32.25 3 1 . 6 631.250.5%1.5%1.5% 31.02 3 0 . 9 8 32.04 30.8730.2831.3131.16 34.19 34.12 34.0433.75 27.62 27.15 26.85 27.65 31.813 2 . 0 1 3 2 . 1 0 32.0032.0231.9731.853 1 . 2 3 2.7%2.0%2.6%2.8%2.1% 2.1% 1.9%2.1%2.3%2.3% 2.0% 2.2%2.8%2.5%2.8% 1 . 6%1.6%1.8%2.2%2.1%1.6%3.4 % 2.4%2.0%2.1%5.6%6 : 15:15:1 4:1 4:1 4:1 6:14:14:18:14:1 4:1 4:1 4:1 5:1 5:1 10:1 9:1 8:14:1 6:1 5:1 4:1 4:1 7:1 6:15:16:17.9%6:1 3 1 . 7 431.453 1 . 6 531.9931.58 3 1 . 2 91.0%1.0%6' SIDEWALK 0.8% 0 . 6%0.5%2.4%2.1%1.1%3 1 . 4 6 PROPOSED CURB INLET PROPOSED CURB INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET PROPOSED AREA INLET 31.25PROPOSED AREA INLET PROPOSED 2' CONCRETE PAN 32.92 1.0%0.7%31.5732.252.0%2.3%32.8232.3432.331.5%1.5%3.2% 2.0% KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 NORTH ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R C 502GRADING PLAN 10MATCH LINE - SEE SHEET C 501 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3.ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD 88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4.ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 5.LOT GRADING IS DESIGNED FOR TYPICAL RECTANGULAR FOOTPRINT WITH DIMENSIONS AS SHOWN HEREON. SHOULD BUILDING FOOTPRINT CHANGE, GRADING SHALL BE ADJUSTED BY PLOT PLAN FOR THE SPECIFIC FOOTPRINT. ALL MINIMUM OPENINGS SHALL BE A MINIMUM OF 18" ABOVE FRONT LOT ELEVATIONS AND PLOT PLAN DESIGN SHALL MEET FHA GRADING GUIDELINES AND BUILDING CODE REQUIREMENTS. NOTES: PROPOSED STORM INLET 2.0% (47.45 ) EXISTING SPOT ELEVATION EXISTING LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) 33.43 EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPOSED RIGHT OF WAY ALOT TYPE LEGEND: PROPOSED GRADE BREAK RAIN GARDEN BIOMEDIA AREA C 502 C 501 UDUDUDUDCCC/ / / / / / / /CLAKEWOOD DRIVE 5' SIDEWALK 5' SIDEWALK 30' FL-FL57' ROWDEL MAR STREET9' UTILITY EASEMENT 9' UTILITY EASEMENT 31" DRIVE OVER CURB & GUTTER LOT 3 LOT 7 LOT 4 LOT 1 LOT 2 LOT 6 LOT 9 LOT 8 LOT 5 RAINGARDEN ADETENTION POND 3 3' DRAINAGE EASEMENT (TYP.) PROPOSED 2' SIDEWALK CULVERT ±40' FL-FL 60' ROW PROPOSED SAWCUT DEL MAR STREET FLOWLINE (SEE SHEET C 602) 5025 5030 5035 5040 5045 5050 5025 5030 5035 5040 5045 5050 9+50 10+00 11+00 12+00 13+00 13+505037.855036.985036.105035.265034.605034.155033.905033.785033.655033.535033.40-0.50% -3.50 %PVI STA = 10+15.77PVI ELEV = 5038.18PVI STA = 12+90.05PVI ELEV = 5033.3390.0' VC PVI STA = 11+31.64 PVI ELEV = 5034.12 BCVS: 10+86.64BVCE: 5035.70ECVS: 11+76.64EVCE: 5033.90A.D. = 3.00 K = 30.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND (-3.39 % ) KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH CENTERLINE LAKEWOOD DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET C 600PLAN & PROFILELAKEWOOD DRIVE11 LAKEWOOD DRIVE 5015 5020 5025 5030 5035 5040 5015 5020 5025 5030 5035 5040 9+50 10+00 11+00 12+00 13+00 14+005030.935030.685030.435030.185029.935029.685029.435029.185028.995028.875028.745028.625028.495028.375028.245028.12-0.50% -1.00%PVI STA = 10+00.00PVI ELEV = 5030.93PVI STA = 11+88.65PVI ELEV = 5029.05PVI STA = 13+80.82PVI ELEV = 5028.09PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND(-1.5%) X X XFDC DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS SOUTH SHIELDS STREETWESTWARD DRIVE 5' SIDEWALK 9' UTILITY EASEMENT 17' CL-FL 30" VERTICAL CURB & GUTTER TRACT B AE,DE,UE PROPOSED 2' CONCRETE PAN PROPOSED STORM DRAIN 26' EMERGENCY ACCESS EASEMENT EXISTING DRIVE-OVER CURB & GUTTER W/ ATTACHED 3' SIDEWALK ±20' CL-FL ±30' HALF ROW PROPOSED DRIVEWAY APPROACH PROPOSED SAWCUT OWNER: POPPE, DAVID A. 1205 WESTWARD DR. KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE NORTH RIGHT FLOWLINE WESTWARD DRIVE SCALE : 1" = 40' (H) 1" = 5' (V) SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET C 601RIGHT FLOWLINE - PLAN & PROFILEWESTWARD DRIVE12 ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R WESTWARD DRIVE 5025 5030 5035 5040 5045 5050 5025 5030 5035 5040 5045 5050 9+50 10+00 11+00 12+00 13+00 13+505040.255039.845039.405038.955038.505038.145037.795037.455037.135036.845036.615036.37-1.40% -1.25% -0.95% -1.65% -1.65% -1.80%PVI STA = 10+00.00PVI ELEV = 5040.25PVI STA = 10+05.97PVI ELEV = 5040.15PVI STA = 10+29.77PVI ELEV = 5039.76PVI STA = 11+01.33PVI ELEV = 5038.47PVI STA = 11+71.33PVI ELEV = 5037.49PVI STA = 12+17.90PVI ELEV = 5036.91PVI STA = 12+78.65PVI ELEV = 5036.33PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE (1.46%) (-0.91%)/ / / / / / / /XXXXXOHUFODEL MAR STREET LAKEWOOD DRIVE 5' SIDEWALK 9' UTILITY EASEMENT 5' SIDEWALK 9' UTILITY EASEMENT 20' CL-FL 31" DRIVE-OVER CURB & GUTTER LOT 1 LOT 2 LOT 9 LOT 8 LAKEWOOD DRIVE (SEE SHEET C 600) 60' ROW 40' FL-FL EXISTING HOLLYWOOD CURB, GUTTER, & SIDEWALK OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. PROPOSED SAWCUT EXISTING HOLLYWOOD CURB, GUTTER, & SIDEWALK EXISTING HOLLYWOOD CURB, GUTTER, & SIDEWALK KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE NORTH RIGHT FLOWLINE DEL MAR STREET SCALE : 1" = 40' (H) 1" = 5' (V) SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED EDGE OF ASPHALT PROPOSED STORM MANHOLE / / / / / / / / PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1.THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 4.SEE INTERSECTION DETAIL SHEETS FOR INTERSECTION DESIGNS. 5.EXISTING AND PROPOSED MANHOLE RIMS AND VALVE BOX LIDS TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE PROPOSED STORM INLET ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 C 602RIGHT FLOWLINE - PLAN & PROFILEDEL MAR STREET13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R DEL MAR STREET / / / / / / / // / / / / / / // / / / / / / /5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 30' FL-FL57' ROW R20' R20'DEL MAR STREET36.863 7 . 3 6 38.473 7 . 4 9 35.383 5 . 3 8 35.80LOT 1 LOT 2 LOT 9 LOT 8 9' UTILITY EASEMENT 9' UTILITY EASEMENT LAKEWOOD DRIVE 31" DRIVE OVER CURB & GUTTER 3' DRAINAGE EASEMENT (TYP.)37.9337.193 8 . 0 7(38.71)(38.28)(39.28)1.8%1.2%2.0% 2.0% 3.4%3.5%2.2%2.2%3.6%3.6%5.0%3.5% 65' CROWN TRANSITION 35.9336.614.5%4.0% SAWCUT LINE (3.9%) (3.4%) (3.7%)(0.8%)(1.3%)(1.9%)(2.0%)UDUDUDUDUDUDUDPROPOSED 2' SIDEWALK CULVERT 31" DRIVE OVER CURB & GUTTER R50' R50' R50' LAKEWOOD DRIVE 3 2 . 2 332.663 2 . 6 7 3 2 . 2 3 33.333 3 . 2 9 33.2933.71LOT 3 LOT 4 LOT 5 LOT 7 LOT 6 RAINGARDEN A5' SIDEWALK 5' SIDEWALK 8.5' PARKWAY 8.5' PARKWAY 9' UTILITY EASEMENT 9' UTILITY EASEMENT 30' FL-FL 57' ROW 3' DRAINAGE EASEMENT (TYP.)2.2%2.2%2.0%2.0%3.3%0.8%0.9%0.8% 1.0 % 1.4 % 0.5% 0.5% 0.5% 1.4% 1.0% 0.8 % 0.5%31.583.0% 3.0 % NORTH C 603INTERSECTION DETAIL DEL MAR STREET & LAKEWOOD DRIVE14 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 KEYMAP SOUTH SHIELDS STREETSPRINGFIELD DRIVE WESTWARD DRIVE / / / / / / / / NOTES: 1.SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 2.EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS\TRAILS AT MAXIMUM SPACING OF 50 FEET. 3.SEE ROADWAY PLAN & PROFILE SHEETS FOR ADDITIONAL INFORMATION. LEGEND: EXISTING LIGHT POLE PROPOSED LIGHT POLE EXISTING LOT LINE SAWCUT LINE EASEMENT LINE PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED STORM INLET PROPOSED RIGHT-OF-WAY PROPOSED CONCRETE CROSSPAN (TYP.) PEDESTRIAN ACCESS RAMPS PROPOSED CENTERLINE PROPOSED CURB & GUTTER PROPOSED STORM MANHOLE PROPOSED EDGE OF ASPHALT EXISTING STORM SEWER PROPOSED STORM SEWER EXISTING RIGHT-OF-WAY CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R ( IN FEET ) 1 inch = ft. Feet02020 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R 1 INTERSECTION DETAIL DEL MAR STREET & LAKEWOOD DRIVE DEL MAR STREET & LAKEWOOD DRIVE 2 INTERSECTION DETAIL LAKEWOOD DRIVE CUL-DE-SAC LAKEWOOD DRIVE CUL-DE-SAC X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XELEC D D D D D D STX STSTSTSTSTSTSTSTSTSTSTSTS T STXX X X X X X X X XXXXX XXXXXXE E X X X X X X X X X X XX X X X XXXXXXXXXXXXXXXX CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRR CONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRRCONTROL IRR XXXXXXXXXX D D 2.74 ac. H1 2.65 ac. H2 0.52 ac. OS-2 0.93 ac. OS-4 0.13 ac. OS-1 h1 h2 0.40 ac. OS-3 os-2 os-3 os-1 os-4 SOUTH SHIELDS STREETSPRIN G F I E L D D R I V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 C 700HISTORIC DRAINAGE EXHIBIT 15 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE PRELIMINARY DRAINAGE REPORT FOR FISCHER PROPERTIES BY NORTHERN ENGINEERING, DATED AUGUST 24, 2022 FOR ADDITIONAL INFORMATION. A LEGEND: FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION X X X XXXXX XXXXXXXXXXX XXXXXXXXX X X XD D D D D D STSTSTSTSTSTSTSTSTSTSTSTSTS T STF.O. F.O. D D / / / / / / / /0.52 ac. OS-2 GGGGGGGGT T G G G G E E E E E E E E EEEEEEEEEEE E EEEE FDC EEEEENYLOPLASTDO NOT P O L L U T E DRAINS T O WATERWA Y S DO NOT POLL U T E D R A I N S T O W A T E R W A Y S NYLOPLAST D U C T I L E I R O N UDUD UD UD UD UD NYLOPLASTDO NOT P O L L U T E DRAINS TOWATERWA Y S DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLAST DUCTILE IRONUDUDUDUDDS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DS DSDS DS NYLOP L AS T DO NOT PO L L UT EDRAINS TO WATERW A YS DO NOT PO L L U TE D RA I N S TO W A TE R W A YS NYLOPLAS T D U C T I LE I R ON / / / / / / / /2.24 ac. 200 100 2.31 ac. 300 0.40 ac. OS-3 0.93 ac. OS-4 0.13 ac. OS-1 200 300 STORMTECH CHAMBERS 2 PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED 2' CONCRETE PAN PROPOSED 2' CONCRETE PAN OS-2 OS-1 OS-3 OS-4 PROPOSED UNDERDRAIN PROPOSED SIDEWALK CULVERT PROPOSED UNDERDRAIN 5' SIDEWALK 5' SIDEWALK SOUTH SHIELDS STREETSPRIN G F I E L D D R I V E WESTWARD DRIVE DEL MAR STREETLAKEWOOD DRIVE EXISTING STORM DRAIN EXISTING STORM DRAIN 9' UTILITY EASEMENT 9' UTILITY EASEMENT DETENTION POND 3 EXISTING 24" STORM DRAIN LOT 3 LOT 4 LOT 1 LOT 2 LOT 5 LOT 7 LOT 6 LOT 9 LOT 8 BLOCK 1 BLOCK 1 TRACT B AE,DE,UE 6' SIDEWALK 5' SIDEWALK 6' SIDEWALK30' FL-FL57' ROW OWNER: POPPE, DAVID A. 1205 WESTWARD DR. OWNER: MARX, NICHOLAS J./ JILL B. JARVIS 1209 WESTWARD DR. OWNER: GRIFFITHS, THOMAS 1213 WESTWARD DR. OWNER: WAYFARE HOME RENTAL, LLC. 1217 WESTWARD DR. OWNER: BOWEN, ZACHARY H. 1200 DEL MAR ST. OWNER: LAJEUNESSE, ROBERT M./ IRINA V. 1220 SPRINGFIELD DR. OWNER: MIRANDA, JOHN E./ YVONNE C. 1212 SPRINGFIELD DR. OWNER: MARTINO, MARY K. 1208 SPRINGFIELD DR. OWNER: RIEUX SYLVIA MARIANNE TRUST 1204 SPRINGFIELD DR. OWNER: JRB HOLDINGS, LLC. 1200 SPRINGFIELD DR. OWNER: CARLSON, BEVERLY A. 1301 S. SHIELDS ST. 100-YR WSEL 100-YR WSEL 0.84 ac. 100 PROPOSED 2' CONCRETE PAN 0.04 ac. OF-2 0.23 ac. OF-1 DETENTION POND 1 UNDERGROUND DETENTION POND 2. RAIN GARDEN A LID VOL. = 2,152 CU.FT. LID WSEL = 5031.31 OF CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 SheetFISCHER PROPERTIESThese drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETof 16 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET A DESIGN POINT FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 11 NOTES: 1.REFER TO THE PRELIMINARY DRAINAGE REPORT FOR FISCHER PROPERTIES BY NORTHERN ENGINEERING, DATED AUGUST 24, 2022 FOR ADDITIONAL INFORMATION. A LEGEND: C 701DRAINAGE EXHIBIT 16 FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION Rational Flow Summary | Developed Basin Flow Rates BASIN TOTAL AREA (acres) Tc2 (min) Tc100 (min) C2 C100 Q2 (cfs) Q100 (cfs) 100 0.60 6.9 6.9 0.63 0.69 0.99 3.76 200 1.83 5.0 5.0 0.83 0.89 4.33 16.20 300 2.64 6.5 6.5 0.61 0.70 4.18 16.74 OF-1 0.23 7.4 7.4 0.33 0.39 0.19 0.77 OF-2 0.04 5.0 5.0 0.70 0.75 0.08 0.31 OS-1 0.13 5.0 5.0 0.81 0.86 0.31 1.13 OS-2 0.52 10.8 10.8 0.44 0.50 0.49 1.96 OS-3 0.40 8.8 8.8 0.43 0.49 0.40 1.60 OS-4 0.93 10.4 10.4 0.33 0.39 0.68 2.79 POND SUMMARY TABLE Pond ID Extended Detention WQCV (CF)LID WQCV (CF) 100-Yr. Detention Vol. (CF) Total Volume (CF) 100-Yr. Detention WSEL(Ft) Peak Release (cfs) Pond 1 546.00 N/A 2,832.00 3,378.00 5,030.03 0.40 Pond 2 N/A 2,209.00 9,843.00 12,052.00 5,029.40 1.99 Pond 3 N/A 2,213.00 16,562.00 18,775.00 5,031.27 1.10 LID Site Summary - New Impervious Area Total Area of Current Development 232,598 ft2 Total On-site Impervious Area 143,631 ft2 75% Required Minimum Area to be Treated by LID 107,723 ft2 Total On-site Impervious Area Treated by LID 127,813 ft2 Percent On-site Impervious Treated by LID 88.99% Additional Off-site Impervious Area Treated by LID 9,176 ft2 Percent Total Impervious Area Treated by LID 95.38% Total Impervious Area Treated by Traditional WQ 13,385 ft2 Percent Impervious Treated by Traditional Water Quality 9.32% Percent Impervious Area Treated by Traditional WQ or LID 104.70%