Loading...
HomeMy WebLinkAboutFISCHER PROPERTIES - PDP220007 - SUBMITTAL DOCUMENTS - ROUND 2 - PHOTOMETRIC PLANPHOTOMETRICPLAN419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710www.VFLA.comDRAWING NUMBER:PROJECT NUMBER:SEAL:IN ASSOCIATION WITH:Strength in design. Strength in partnership.Strength in community.VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC.THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED ORCOPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA.COPYRIGHT:SHEET ISSUANCESDESCRIPTIONDATENOT FOR CONSTRUCTIONFOR REFERENCE ONLYA R C H I T E C T U R E + I N T E R I O R SCIVIL ENGINEER: NORTHERN ENGINEERINGLANDSCAPE ARCHITECT:RIPLEY DEISGN, INC.STRUCTURAL ENGINEER:RAKER PHODES ENGINEERINGMECHANICAL & PLUMBING ENGINEER:INTERGRATED MECHANICALELECTRICAL ENGINEER: APS, INC.1215 S. SHIELDS1215 S. Shields StreetFort Collins, COPDP SUBMITTAL - ROUND 2APS..608.22SCHEMATIC DESIGN04-26-2022PDP SUBMITTAL - ROUND 208-24-2022PM.1 ScheduleSymbolLabelImageQuantityManufacturerCatalog NumberDescriptionNumber LampsLumens Per LampLight Loss FactorWattagePlotBB5Lithonia LightingDSXW1 LED 10C 530 30K T3M MVOLTDSXW1 LED WITH (1) 10 LED LIGHT ENGINES, TYPE T3M OPTIC, 3000K, @ 530mA.12010119.1AA17Lithonia LightingDSX0 LED P1 30K T3M MVOLTDSX0 LED P1 30K T3M MVOLT14248138AA1 HS6Lithonia LightingDSX0 LED P1 30K T3M MVOLT HSDSX0 LED P1 30K T3M MVOLT with houseside shield13442138AA1Lithonia LightingDSX0 LED P1 30K T2M MVOLTDSX0 LED P1 30K T2M MVOLT14364138AA HS1Lithonia LightingDSX0 LED P1 30K T2M MVOLT HSDSX0 LED P1 30K T2M MVOLT with houseside shield13576138DD2Lithonia LightingRADPT P2 30K PATH HSRADEAN Post-Top with P2 3000K Pathway distribution with house-side shield13509138.0107CC8Lithonia LightingWF6 LED 27K30K35K MVOLT 90CRI 3000K6" LED Wafer Selectable White MVOLT 27K30K35K _ 3000K11221113.35BUGRATINGB1-U0-G1B1-U0-G1B1-U0-G1B1-U0-G1B1-U0-G1B1-U0-G2B1-U0-G0StatisticsDescriptionSymbolAvgMaxMinMax/MinAvg/MinCalc Zone #40.3 fc8.7 fc0.0 fcN/AN/ALuminaire LocationsNo.LabelXYZLocationMHOrientationTiltXYAimZ1AA1 HS169.16101.0125.0025.0090.000.00170.91101.010.002AA1 HS87.2272.3525.0025.0090.440.0088.9772.340.003AA1 HS86.99-12.6125.0025.0089.740.0088.74-12.600.008AA1 HS114.76-99.6125.0025.0044.080.00115.98-98.360.009AA1 HS195.42-101.9525.0025.000.000.00195.42-100.200.0010AA1 HS392.11-94.7425.0025.000.000.00392.11-92.990.002AA292.92-64.0525.0025.00180.000.00292.92-65.800.001AA1154.2230.0325.0025.00270.000.00152.4730.030.002AA1154.2230.0325.0025.0090.090.00155.9730.020.004AA1217.55-8.1625.0025.00180.560.00217.53-9.910.005AA1293.02-37.4425.0025.000.000.00293.02-35.690.006AA1396.67-11.8325.0025.00227.060.00395.39-13.020.008AA1152.99-39.1325.0025.0090.210.00154.74-39.140.0011AA1357.70-37.0825.0025.000.000.00357.70-35.330.001AA HS199.46174.9525.0025.00270.000.00197.71174.950.001BB229.1833.9920.0020.00269.330.00229.1833.990.002BB251.5727.038.008.00180.000.00251.5727.030.003BB333.9515.578.008.00180.000.00333.9515.570.004BB433.20-63.9620.0020.00180.000.00433.20-63.960.005BB277.3426.5216.0016.00180.000.00277.3426.520.001CC439.88-65.538.008.000.000.00439.88-65.530.002CC448.07-65.538.008.000.000.00448.07-65.530.003CC343.0713.168.008.00135.000.00343.0713.160.004CC350.9413.168.008.000.000.00350.9413.160.005CC298.23171.1910.0010.0094.690.00298.23171.190.006CC305.25171.1910.0010.000.000.00305.25171.190.007CC297.46125.0910.0010.0090.000.00297.46125.090.008CC305.43124.9310.0010.00180.000.00305.43124.930.001DD280.0942.6012.0012.0091.040.00280.0942.600.002DD319.3840.8712.0012.00270.000.00319.3840.870.00419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710www.VFLA.comDRAWING NUMBER:PROJECT NUMBER:SEAL:IN ASSOCIATION WITH:Strength in design. Strength in partnership.Strength in community.VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC.THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED ORCOPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA.COPYRIGHT:SHEET ISSUANCESDESCRIPTIONDATENOT FOR CONSTRUCTIONFOR REFERENCE ONLYA R C H I T E C T U R E + I N T E R I O R SCIVIL ENGINEER: NORTHERN ENGINEERINGLANDSCAPE ARCHITECT:RIPLEY DEISGN, INC.STRUCTURAL ENGINEER:RAKER PHODES ENGINEERINGMECHANICAL & PLUMBING ENGINEER:INTERGRATED MECHANICALELECTRICAL ENGINEER: APS, INC.1215 S. SHIELDS1215 S. Shields StreetFort Collins, COPDP SUBMITTAL - ROUND 2APS..608.22SCHEMATIC DESIGN04-26-2022PDP SUBMITTAL - ROUND 208-24-20223.2.4 - EXTERIOR LIGHTING SUMMARY TABLELighting Context Area : LC1REQUIREMENTSITEMTOTAL SITE LUMENS ALLOWEDPROVIDEDITEMB3U0G1PHOTOMETRICSCHEDULESPM.2419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710www.VFLA.comDRAWING NUMBER:PROJECT NUMBER:SEAL:IN ASSOCIATION WITH:Strength in design. Strength in partnership.Strength in community.VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC.THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED ORCOPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA.COPYRIGHT:SHEET ISSUANCESDESCRIPTIONDATENOT FOR CONSTRUCTIONFOR REFERENCE ONLYA R C H I T E C T U R E + I N T E R I O R SCIVIL ENGINEER: NORTHERN ENGINEERINGLANDSCAPE ARCHITECT:RIPLEY DEISGN, INC.STRUCTURAL ENGINEER:RAKER PHODES ENGINEERINGMECHANICAL & PLUMBING ENGINEER:INTERGRATED MECHANICALELECTRICAL ENGINEER: APS, INC.1215 S. SHIELDS1215 S. Shields StreetFort Collins, COPDP SUBMITTAL - ROUND 2APS..608.22SCHEMATIC DESIGN04-26-2022PDP SUBMITTAL - ROUND 208-24-2022 PHOTOMETRICCUT SHEETSPM.3419 Canyon Ave Suite 200, Fort Collins, CO 80521 | 970.224.1191108 East Lincolnway, Cheyenne, WY 82001 | 307.635.5710www.VFLA.comDRAWING NUMBER:PROJECT NUMBER:SEAL:IN ASSOCIATION WITH:Strength in design. Strength in partnership.Strength in community.VAUGHT FRYE LARSON ARONSON ARCHITECTURE + INTERIORS, INC.THIS DRAWING MAY NOT BE PHOTOGRAPHED, SCANNED, TRACED ORCOPIED IN ANY MANNER WITHOUT THE WRITTEN PERMISSION OF VFLA.COPYRIGHT:SHEET ISSUANCESDESCRIPTIONDATENOT FOR CONSTRUCTIONFOR REFERENCE ONLYA R C H I T E C T U R E + I N T E R I O R SCIVIL ENGINEER: NORTHERN ENGINEERINGLANDSCAPE ARCHITECT:RIPLEY DEISGN, INC.STRUCTURAL ENGINEER:RAKER PHODES ENGINEERINGMECHANICAL & PLUMBING ENGINEER:INTERGRATED MECHANICALELECTRICAL ENGINEER: APS, INC.1215 S. SHIELDS1215 S. Shields StreetFort Collins, COPDP SUBMITTAL - ROUND 2APS..608.22SCHEMATIC DESIGN04-26-2022PDP SUBMITTAL - ROUND 208-24-2022FIXTURE TYPE 'BB' (WALL LIGHT )FIXTURE TYPE 'AA' SERIES (POLE LIGHT )FIXTURE TYPE 'CC' (DOWNLIGHT )FIXTURE TYPE 'DD' (POST TOP LIGHT )