Loading...
HomeMy WebLinkAboutPOWERHOUSE 2 - PDP220006 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (4)E. VINE DRIVEN. COLLEGE AVENUECHERRY STREET CAC H E L A P O U D R E R I V E R SheetPOWERHOUSE 2These drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 13 CS1 COVER STEET1 APRIL 2022 CONTACT INFORMATION PROJECT TEAM: VICINITY MAP NORTH PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 1-00 ON A CATCH BASIN AT THE SOUTHEAST CORNER OF VINE DR. AND COLLEGE AVE. ELEV.=4968.74 CITY OF FORT COLLINS BENCHMARK 3-13 APPROX. 40 FT SOUTH OF THE LINDEN ST. BRIDGE OVER THE POUDRE RIVER, ON THE WEST SIDE OF LINDEN ST. , ON A STORM INLET. ELEV.=4962.27 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.18' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE WEST LINE LINE OF THE SOUTHWEST QUARTER OF SECTION 1-7-69 AS BEARING SOUTH 00° 38' 34" WEST (ASSUMED BEARING) AND MONUMENTED AS SHOWN ON PLAT. PROJECT BENCHMARKS: POWERHOUSE 2 PROJECT TEAM: Roger Sherman BHA Design Incorporated 1603 Oakridge Drive, Suite 100 Fort Collins, Colorado 80525 (970)223-7577 Colorado State University Bryan Willson Executive Director, CSU Energy Institute 450 N College Ave. Fort Collins, CO 80524 (970)227-5164 Northern Engineering Services, Inc. Andy Reese 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT OWNER/APPLICANT SITE ENGINEER SHEET INDEX A PARCEL OF LAND LOCATED IN THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SITE SURVEYOR 1 CS1 COVER SHEET 2 CS2 GENERAL & CONSTRUCTION NOTES 4 EX1 EXISTING CONDITIONS & DEMOLITION PLAN 5 PV1 PAVING PLAN UTILITY SHEETS 6 OU1 OVERALL UTILITY PLAN GRADING SHEETS 7 OG1 OVERALL GRADING PLAN 8 G1 GRADING PLAN 9 G2 GRADING PLAN DRAINAGE SHEETS 10 EC1 EROSION CONTROL PLAN 11 EC2 EROSION CONTROL DETAILS 12 DR1 DRAINAGE EXHIBIT 13 FP1 FLOODPLAIN EXHIBIT PRELIMINARY CONSTRUCTION PLANS FOR E N G I N E E R N GI EHTRON R N E N G I N E E R N GI EHTRON R N CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R PROJECT LOCATION UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840 ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306 CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401 WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854 APPROVED: City Engineer:Approved Sheets Date Water & Wastewater Utility Approved Sheets Date Stormwater Utility Approved Sheets Date Park Planning and Development Approved Sheets Date Traffic Operations Approved Sheets Date Environmental Planner Approved Sheets Date City of Fort Collins, Colorado UTILITY PLAN APPROVAL APPROVED: APPROVED: APPROVED: APPROVED: APPROVED: Original Field Survery: Northern Engineering Services, Inc. Date: December, 2017 FIELD SURVEY BY: These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CTL Thompson, Inc Geotechnical Investigation Proposed Improvements Powerhouse 2 Project No. FC10223-125 Date: March 14, 2022 SUBSURFACE EXPLORATION BY: I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. CERTIFICATION STATEMENT: Travel 69' ROW (min.) 42' Roadway 5' Walk (min.)(min.) Pkwy. 8.5' Pkwy. 5' (min.) 8.5' 11' Util. Esmt. 9' Esmt. Util. 9' (min.) Walk Travel 11' 7' Lane Bike 3'7' Lane Bike 3' Bike Lane Buffer Bike Lane Buffer 2 LANE ARTERIAL w/ PARELLEL PARKING (EAST VINE DRIVE) 2 LANE COLLECTOR (JEROME STREET) (min.) Walk 99' ROW (min.) 52' Roadway 7' Pkwy. 6' (min.) 9.5' Esmt. Util. 9' Center 10' Travel 11' Travel 11' 3' Lane Bike 7'3' Bike Lane Buffer Bike Lane Buffer Lane Bike (min.) Walk 84' ROW (min.) 52' Roadway 7' Walk (min.) (min.) Pkwy. 10' Pkwy. 6' (min.) 10' Util. Esmt. 15' Esmt. Util. 15' Center 10' Travel 11' Travel 11' 3' Lane Bike 7'3' Bike Lane Buffer 6' Bike Lane Buffer Lane Bike 8' Parallel Parking (min.) Walk Pkwy. 6' (min.) 9.5' Esmt. Util. 9' 8' Parallel Parking 2 LANE ARTERIAL (EAST VINE DRIVE) T VAULT F.O. VAULT F.O.F.O. CONTROL IRR CONTROL IRR GAS XXXXXXOHUOHU6' SIDEWALK6' SIDEWALK 17' 24' 17' 9' 17' 9' 9' 24' FL-FL 24' 17'9' PROPOSED CURB RAMP 12' CITY TRAIL 12' CITY TRAIL PROPOSED CURB RAMP PROPOSED CURB RAMPPROPOSED CURB RAMP PROPOSED 8' CONCRETE PAN 9'17' 17'9' 17' 9' 9' 17' PROPOSED CURB RAMP 24'5' ADA RAMP 5' ADA RAMP 5' ADA RAMP 5' ADA RAMP PROPOSED STAIRS 11.75' SIDEWALK26.74' SIDEWALK11.69' SIDEWALK6' SIDEWALKEAST VINE DRIVENORTH COLLEGE AVENUEEXISTING 30' GAS LINE EASEMENT PROPERTY BOUNDARY 100 YR FLOOD PLAIN (CURRENT EFFECTIVE) EXISTING 10' UTILITY EASEMENT EXISTING 10' UTILITY EASEMENT EXISTING 30' UTILITY & DRAINAGE EASEMENT LAKE CANAL EASEMENT WIDTH VARIES UTILITY YARD EXISTING TREE (TYP.) PROPOSED JEROME STREET CONNECTION & BRIDGE LAKE C A N A L 17'9' 24' PROPOSED 10' CONCRETE PAN PROPOSED 10' CONCRETE PAN PROPOSED CURB RAMP 6' 8' SIDEWALK 6' SIDEWALKPROPOSED BUILDING 100 YEAR FLOOD PLAIN (CURRENT EFFECTIVE) 9'17' 9' 17' 9' 17' 9' 24'JEROME STREETJEROME STREET LLC, 216 E OAK ST FORT COLLINS JEROME STREET STATION LLC, 742 N COLLEGE AVE FORT COLLINS LMC VENTURES LLC, 742 N COLLEGE AVE FORT COLLINS CITY OF FORT COLLINS 405 N COLLEGE AVE FORT COLLINS MORAK KAREN LLC 622 N COLLEGE AVE FORT COLLINS 20' EMERGENCY ACCESS EASEMENT 20' EMERGENCY ACCESS EASEMENT 20' EMERGENCY ACCESS EASEMENT 50' CITY TRAIL EASEMENT 50' CITY TRAIL EASEMENT PROPOSED 18" VERTICAL CURB & GUTTER CITY OF FORT COLLINS, 740 N COLLEGE AVE FORT COLLINS PROPOSED 8' CONCRETE PAN PROPOSED BUS STOP 30' CANAL EASEMENT PROPOSED 18" VERTICAL CURB & GUTTER PROPOSED 18" VERTICAL CURB & GUTTER PROPOSED 18" VERTICAL CURB & GUTTER PROPOSED 18" VERTICAL CURB & GUTTER 11 1 1 1 1 1 1 2 2 2 22 22 3 3 3 9' UTILITY EASEMENT 9' UTILITY EASEMENT LAKE CANAL EASEMENT WIDTH VARIES 8' 4 4 PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS PROPOSED 30" CURB & GUTTER PROPOSED 30" CURB & GUTTEREXISTING 30" CURB & GUTTER EXISTING 30" CURB & GUTTER EXISTING 30" CURB & GUTTER EXISTING 30" CURB & GUTTER PROPOSED OUTDOOR CLASS ROOM FLUSH CURB 11 PROPOSED CURB CUT & RIPRAP RUN DOWN FLUSH CURB PROPOSED BIKE RACKS (TYP.) 23' SheetPOWERHOUSE 2These drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 13 PV1 PAVING PLAN5 NORTH ( IN FEET ) 1 inch = ft. Feet04040 40 80 120 EASEMENTS NOTES: 1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND PROJECT SPECIFICATION MANUAL. 3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS. 4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK. 6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. PROPOSED VERTICAL CURB & GUTTER PROPERTY BOUNDARY EXISTING LOT LINE ASPHALT PAVING PROPOSED OUTFALL VERTICAL CURB & GUTTER LEGEND: CONCRETE PAVING GRAVEL PARKING SITE SIGN LEGEND 1LANE FIRE NO PARKING RESERVED PARKING 2 P0TS 3 4 25.06' CONCRETE FLATWORK CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. before you dig.Call R CRUSHER FINES