HomeMy WebLinkAboutPOWERHOUSE 2 - PDP220006 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANS (4)E. VINE DRIVEN. COLLEGE AVENUECHERRY STREET
CAC
H
E
L
A
P
O
U
D
R
E
R
I
V
E
R
SheetPOWERHOUSE 2These drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 13
CS1 COVER STEET1
APRIL 2022 CONTACT INFORMATION
PROJECT TEAM:
VICINITY MAP
NORTH
PROJECT DATUM: NAVD88
CITY OF FORT COLLINS BENCHMARK 1-00
ON A CATCH BASIN AT THE SOUTHEAST CORNER OF VINE DR. AND COLLEGE AVE.
ELEV.=4968.74
CITY OF FORT COLLINS BENCHMARK 3-13
APPROX. 40 FT SOUTH OF THE LINDEN ST. BRIDGE OVER THE POUDRE RIVER, ON
THE WEST SIDE OF LINDEN ST. , ON A STORM INLET.
ELEV.=4962.27
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR
VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE
FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.18'
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE WEST LINE LINE OF THE SOUTHWEST QUARTER
OF SECTION 1-7-69 AS BEARING SOUTH 00° 38' 34" WEST (ASSUMED BEARING)
AND MONUMENTED AS SHOWN ON PLAT.
PROJECT BENCHMARKS:
POWERHOUSE 2
PROJECT TEAM:
Roger Sherman
BHA Design Incorporated
1603 Oakridge Drive, Suite 100
Fort Collins, Colorado 80525
(970)223-7577
Colorado State University
Bryan Willson
Executive Director, CSU Energy Institute
450 N College Ave.
Fort Collins, CO 80524
(970)227-5164
Northern Engineering Services, Inc.
Andy Reese
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
PLANNER/
LANDSCAPE ARCHITECT
OWNER/APPLICANT
SITE ENGINEER
SHEET INDEX
A PARCEL OF LAND LOCATED IN THE SOUTHWEST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH,
RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 North Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
SITE SURVEYOR
1 CS1 COVER SHEET
2 CS2 GENERAL & CONSTRUCTION NOTES
4 EX1 EXISTING CONDITIONS & DEMOLITION PLAN
5 PV1 PAVING PLAN
UTILITY SHEETS
6 OU1 OVERALL UTILITY PLAN
GRADING SHEETS
7 OG1 OVERALL GRADING PLAN
8 G1 GRADING PLAN
9 G2 GRADING PLAN
DRAINAGE SHEETS
10 EC1 EROSION CONTROL PLAN
11 EC2 EROSION CONTROL DETAILS
12 DR1 DRAINAGE EXHIBIT
13 FP1 FLOODPLAIN EXHIBIT
PRELIMINARY CONSTRUCTION PLANS FOR
E N G I N E E R N GI
EHTRON R N
E N G I N E E R N GI
EHTRON R N
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
PROJECT
LOCATION
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
GAS-----------------Xcel Energy-----------------------------Pat Kreager (970) 225-7840
ELECTRIC--------City of Fort Collins Light & Power--Cody Snowdon (970) 416-2306
CABLE-------------Comcast----------------------------------Don Kapperman (970) 567-0425
TELECOM.--------CenturyLink-------------------------------William Johnson (970) 377-6401
WATER------------City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854
WASTEWATER--City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854
STORMWATER-City of Fort Collins Utilities-----------Heidi Hansen (970) 221-6854
APPROVED:
City Engineer:Approved Sheets Date
Water & Wastewater Utility Approved Sheets Date
Stormwater Utility Approved Sheets Date
Park Planning and Development Approved Sheets Date
Traffic Operations Approved Sheets Date
Environmental Planner Approved Sheets Date
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
APPROVED:
APPROVED:
APPROVED:
APPROVED:
APPROVED:
Original Field Survery:
Northern Engineering Services, Inc.
Date: December, 2017
FIELD SURVEY BY:
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CTL Thompson, Inc
Geotechnical Investigation Proposed Improvements
Powerhouse 2
Project No. FC10223-125
Date: March 14, 2022
SUBSURFACE EXPLORATION BY:
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
CERTIFICATION STATEMENT:
Travel
69' ROW (min.)
42' Roadway
5'
Walk
(min.)(min.)
Pkwy.
8.5'
Pkwy.
5'
(min.)
8.5'
11'
Util.
Esmt.
9'
Esmt.
Util.
9'
(min.)
Walk
Travel
11'
7'
Lane
Bike
3'7'
Lane
Bike
3'
Bike
Lane
Buffer
Bike
Lane
Buffer
2 LANE ARTERIAL w/ PARELLEL PARKING
(EAST VINE DRIVE)
2 LANE COLLECTOR
(JEROME STREET)
(min.)
Walk
99' ROW (min.)
52' Roadway
7'
Pkwy.
6'
(min.)
9.5'
Esmt.
Util.
9'
Center
10'
Travel
11'
Travel
11'
3'
Lane
Bike
7'3'
Bike
Lane
Buffer
Bike
Lane
Buffer
Lane
Bike
(min.)
Walk
84' ROW (min.)
52' Roadway
7'
Walk
(min.)
(min.)
Pkwy.
10'
Pkwy.
6'
(min.)
10'
Util.
Esmt.
15'
Esmt.
Util.
15'
Center
10'
Travel
11'
Travel
11'
3'
Lane
Bike
7'3'
Bike
Lane
Buffer
6'
Bike
Lane
Buffer
Lane
Bike
8'
Parallel
Parking
(min.)
Walk
Pkwy.
6'
(min.)
9.5'
Esmt.
Util.
9'
8'
Parallel
Parking
2 LANE ARTERIAL
(EAST VINE DRIVE)
T VAULT
F.O.
VAULT
F.O.F.O.
CONTROL
IRR
CONTROL
IRR
GAS
XXXXXXOHUOHU6' SIDEWALK6' SIDEWALK
17'
24'
17'
9'
17'
9'
9'
24'
FL-FL
24'
17'9'
PROPOSED CURB RAMP
12' CITY TRAIL
12' CITY TRAIL
PROPOSED CURB RAMP
PROPOSED CURB RAMPPROPOSED CURB RAMP
PROPOSED 8' CONCRETE PAN
9'17'
17'9'
17'
9'
9'
17'
PROPOSED CURB RAMP
24'5' ADA RAMP
5' ADA RAMP
5' ADA RAMP
5' ADA RAMP
PROPOSED STAIRS
11.75' SIDEWALK26.74' SIDEWALK11.69' SIDEWALK6' SIDEWALKEAST VINE DRIVENORTH COLLEGE AVENUEEXISTING 30' GAS
LINE EASEMENT
PROPERTY BOUNDARY
100 YR FLOOD PLAIN
(CURRENT EFFECTIVE)
EXISTING 10'
UTILITY EASEMENT
EXISTING 10'
UTILITY EASEMENT
EXISTING 30' UTILITY &
DRAINAGE EASEMENT
LAKE CANAL EASEMENT
WIDTH VARIES
UTILITY YARD
EXISTING TREE (TYP.)
PROPOSED JEROME STREET
CONNECTION & BRIDGE
LAKE
C
A
N
A
L
17'9'
24'
PROPOSED 10' CONCRETE PAN
PROPOSED 10' CONCRETE PAN
PROPOSED CURB RAMP
6'
8' SIDEWALK
6' SIDEWALKPROPOSED BUILDING
100 YEAR FLOOD PLAIN
(CURRENT EFFECTIVE)
9'17'
9'
17'
9'
17'
9'
24'JEROME STREETJEROME STREET LLC,
216 E OAK ST FORT
COLLINS
JEROME STREET STATION
LLC, 742 N COLLEGE AVE
FORT COLLINS
LMC VENTURES LLC,
742 N COLLEGE AVE
FORT COLLINS
CITY OF FORT COLLINS
405 N COLLEGE AVE
FORT COLLINS
MORAK KAREN LLC
622 N COLLEGE AVE
FORT COLLINS
20' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS EASEMENT
20' EMERGENCY
ACCESS EASEMENT
50' CITY TRAIL
EASEMENT
50' CITY TRAIL
EASEMENT
PROPOSED 18" VERTICAL
CURB & GUTTER
CITY OF FORT COLLINS,
740 N COLLEGE AVE
FORT COLLINS
PROPOSED 8' CONCRETE PAN
PROPOSED BUS STOP
30' CANAL EASEMENT
PROPOSED 18" VERTICAL
CURB & GUTTER
PROPOSED 18" VERTICAL
CURB & GUTTER
PROPOSED 18" VERTICAL
CURB & GUTTER
PROPOSED 18" VERTICAL
CURB & GUTTER
11
1
1
1
1
1
1
2 2 2
22
22
3
3
3
9' UTILITY EASEMENT
9' UTILITY EASEMENT
LAKE CANAL EASEMENT
WIDTH VARIES
8'
4 4
PROPOSED STAIRS
PROPOSED STAIRS
PROPOSED STAIRS
PROPOSED STAIRS
PROPOSED STAIRS
PROPOSED 30"
CURB & GUTTER
PROPOSED 30"
CURB & GUTTEREXISTING 30"
CURB & GUTTER
EXISTING 30"
CURB & GUTTER
EXISTING 30"
CURB & GUTTER
EXISTING 30"
CURB & GUTTER
PROPOSED OUTDOOR
CLASS ROOM
FLUSH CURB
11
PROPOSED CURB CUT
& RIPRAP RUN DOWN
FLUSH CURB
PROPOSED BIKE RACKS (TYP.)
23'
SheetPOWERHOUSE 2These drawings areinstruments of serviceprovided by NorthernEngineering Services, Inc.and are not to be used forany type of constructionunless signed and sealed bya Professional Engineer inthe employ of NorthernEngineering Services, Inc.NOT FOR CONSTRUCTIONREVIEW SETENGINEERNGIEHTRONRNFORT COLLINS: 301 North Howes Street, Suite 100, 80521GREELEY: 820 8th Street, 80631970.221.4158northernengineering.comof 13
PV1 PAVING PLAN5
NORTH
( IN FEET )
1 inch = ft.
Feet04040
40
80 120
EASEMENTS
NOTES:
1.SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND
PAVEMENT SECTIONS.
2.PAVEMENT MARKINGS SHALL BE PER CITY OF FORT COLLINS STANDARDS AND
PROJECT SPECIFICATION MANUAL.
3.LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY OF FORT COLLINS ENGINEERING INSPECTOR. ALL REPAIRS
TO BE IN ACCORDANCE WITH CITY OF FORT COLLINS STREET REPAIR STANDARDS.
4.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION,
AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED
OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR
RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE
PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE
ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
5.ALL PUBLIC CONCRETE PAVING SHALL BE 6" THICK.
6.REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION
RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES.
PROPOSED VERTICAL CURB & GUTTER
PROPERTY BOUNDARY
EXISTING LOT LINE
ASPHALT PAVING
PROPOSED OUTFALL VERTICAL CURB & GUTTER
LEGEND:
CONCRETE PAVING
GRAVEL PARKING
SITE SIGN LEGEND
1LANE
FIRE
NO
PARKING
RESERVED
PARKING
2
P0TS
3 4
25.06'
CONCRETE FLATWORK
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
before you dig.Call
R
CRUSHER FINES