Loading...
HomeMy WebLinkAboutSUN COMMUNITIES - THE FOOTHILLS - FDP220005 - SUBMITTAL DOCUMENTS - ROUND 2 - ARCHITECTURAL DETAILS (3)287 287 392 SITE LIST OF DRAWINGS SUMMARY TABLE FUSCO, SHAFFER & PAPPAS, INC. ARCHITECTS AND PLANNERS COPYRIGHT 2022-FUSCO, SHAFFER & PAPPAS, INC. DEVELOPMENT TEAM MECHANICAL / ELECTRICAL ENGINEER STRUCTURAL ENGINEER FUSCO, SHAFFER & PAPPAS, INC. 550 EAST NINE MILE ROAD FERNDALE, MICHIGAN 48220 248.543.4100 ARCHITECT OWNER DATE ISSUE DEVELOPER FOOTHILLS CIVIL ENGINEER MAIL BUILDING FORT COLLINS COLORADO SUN COMMUNITIES A.C.001 CODE ANALYSIS A.101 OVERALL BUILDING PLAN, REFLECTED CEILING PLAN, AND INTERIOR ELEVATIONS A.109 ROOF PLAN AND DETAILS A.201 OVERALL BUILDING ELEVATIONS A.701 DOOR AND ROOM FINISH SCHEDULE ARCHITECTURAL SUN COMMUNITIES 27777 FRANKLIN ROAD SUITE 200 SOUTHFIELD, MICHIGAN 48034−8205 227 S.F. MECHANICAL ELECTRICAL ENGINEERING CONSULTANTS, INC. 14496 N. SHELDON ROAD SUITE 260 PLYMOUTH, MICHIGAN 48170 734.454.5516 ATWELL, L.L.C. 2 TOWNE SQUARE #700 SOUTHFIELD, MICHIGAN 48076 LOCATION MAP NO SCALE NORTH ATWELL 143 UNION BLVD, SUITE 700 LAKEWOOD, CO 80226 303.462.1100 IMEG CORP. 33533 TWELVE MILE ROAD, SUITE 200 FARMINGTON HILLS, MI 48331 248.847.3221 STRUCTURAL ELECTRICAL ZONING PROPOSED PUD - PLANNED UNIT DEVELOPMENT TOTAL GROSS BUILDING AREA BUILDING DATA BUILDING CODE: 2021 INTERNATIONAL BUILDING CODE MBC CONSTR. TYPE: 5B (NON SPRINKLED) USE GROUP: U - UTILITY CODE DATA AMENITY SITE AREA 142,214 S.F. 3.26 ACRES SITE DATA E.001 ELECTRICAL GENERAL INFORMATION E.101 MAIL BUILDING - ELECTRICAL PLAN S.001 GENERAL STRUCTURAL NOTES S.002 GENERAL STRUCTURAL NOTES S.003 GENERAL STRUCTURAL NOTES S.004 SPECIAL INSPECTION SCHEDULES S.101 FIRST FLOOR FOUNDATIONS AND ROOF FRAMING PLAN S.300 TYPICAL CONCRETE AND MASONRY DETAILS S.500 TYPICAL STEEL DETAILS S.700 SECTIONS AND DETAILS 02.18.2022 PERMIT 06.15.2022 CITY COMMENTS FIRE RESISTANCE RATING REQUIREMENTS 2021 iBC CONSTRUCTION TYPE - VB N.F.P.A. CONSTRUCTION TYPE V (000) BUILDING ELEMENT FIRE RATINGS (IBC TABLE 601/602) PRIMARY STRUCTURAL FRAME ZER0 HOUR BEARING WALLS: EXTERIOR ZERO HOUR INTERIOR ZERO HOUR NON-BEARING WALLS AND PARTITIONS: EXTERIOR X < 5 ONE HOUR, 5 < X < 10 ONE HOUR, 10 < X < 30 ZERO HOUR, X >30 ZERO HOUR INTERIOR ZERO HOUR FLOOR CONSTRUCTION AND SECONDARY MEMBERS ZERO HOUR WALL REQUIREMENTS FIRE RATING REQUIRMENTS FURNACE ROOMS W/ EQUIPMENT OVER 400,000 BTU/HR ONE HOUR (IBC TABLE 509) BOILER ROOMS W/ EQUIPMENT OVER 15 PSI AND 10 HP ONE HOUR (IBC TABLE 509) LAUNDRY ROOM OVER 100 S.F. ONE HOUR (IBC TABLE 509) CORRIDOR WALLS ZERO HOUR (PER IBC SECTION 407.3/710/TABLE 1020.1) FIREWALLS TWO HOUR (PER IBC SECTION 706) SMOKE BARRIERS ONE HOUR (PER IBC SECTION 407.5/709) SMOKE PARTITIONS ZERO HOUR (PER IBC SECTION IBC 710) SHAFT ENCLOSURES ONE HOUR (PER IBC SECTION 713.4) EXIT ENCLOSURES ONE HOUR (PER IBC SECTION 707.3.3/713.4) EXIT PASSAGEWAYS ONE HOUR (PER IBC SECTION 707.3.4, 1024.3)) HORIZONTAL EXITS TWO HOUR (PER IBC SECTION 707.3.5, 1026.2) INFORMATION TECHNOLOGY ROOMS ONE HOUR RATED WALLS WITHOUT FIRE SUPPRESSION TWO HOUR RATED CEILING (PER IBC SECTION 903.2) CODE DATA BUILDING CODE: NTERNATIONAL BUILDING CODE - 2021 IBC CONSTRUCTION TYPE: VB NFPA 220 CONSTRUCTION TYPE: V (000) USE GROUP: U - (UTILITY) PLUMBING CODE: INTERNATIONAL PLUMBING CODE - 2021 MECHANICAL CODE: INTERNATIONAL MECHANICAL CODE - 2021 INTERNATIONAL FUEL GAS CODE - 2021 ELECTRICAL CODE: NATIONAL ELECTRICAL CODE - 2020 ENERGY CODE: INTERNATIONAL ENERGY CONSERVATION CODE - 2021 ACCESSIBILITY: ICC/ANSI A117.1 - 2009 FIRE SUPPRESSION: NOT REQUIRED HEIGHT AND AREA MODIFICATIONS-IBC ALLOWABLE AREA CALCULATION (PER IBC SECTION 506) Aa = At + (NS x If) x Sa At = 5,500 S.F. (VB/U) If = (F/P - .25) W/30 = .75 Sa = 1 Aa = [5,500 + (5,500x.75 )] x 1 =9,625 S.F. Aa = ALLOWABLE AREA (S.F.) At = TABULAR ALLOWABLE AREA FACTOR NS = TABULAR ALLOWABLE AREA FOR NON SPRINKLERED BUILDINGS If = AREA FACTOR INCREASE DUE TO FRONTAGE Sa = STORIES ABOVE GRADE PLANE, NOT TO EXCEED 3) TYPE OF CONSTRUCTION VB MAXIMUM PERMITTED HEIGHT PER IBC 1 STORY/40' ACTUAL HEIGHT (TO MIDPOINT OF ROOF ) 1 STORY/13' AREA CALCULATION PROPOSED MAIL BUILDING = 227 S.F. MAX. ALLOW. AREA / FLOOR = 9,625 S.F. MAIL BUILDING 100 1 2MAX TRAVEL DISTANCE = 13'-10"MAX TRAVEL DISTANCE = 13'-10" LIFE SAFETY LEGEND EXIT TRAVEL DISTANCE EGRESS PATH ORIGIN 1. EGRESS WIDTH, THE MINIMUM WIDTH, IN INCHES, OF ANY MEANS OF EGRESS COMPONENT SHALL NOT BE LESS THAN SPECIFIED COMPONENT. 105.3.1 STAIRWAYS: 0.3 (NOT APPLICABLE) 105.3.2 OTHER EGRESS COMPONENTS: 0.15 INCHES PER OCCUPANT EGRESS WIDTH CALCULATIONS DOOR #DOOR DESCRIPTION 1 2 3' 0" ALUMINUM & GLASS 3' 0" ALUMINUM & GLASS EGRESS WIDTH FROM BUILDING = 2 OCCUPANTS x 0.15 INCHES PER OCCUPANT = EGRESS WIDTH REQD. EGRESS WIDTH PROVIDED 34" 34" - - 68".3" STANDARD BARRIER FREE MOUNTING HEIGHTS PICTOGRAM MIN 6"x6" OVERALL SIGNAGE 8"60"CL CL18" MIN18" MINCL SIGNAGE SIGNAGE AND CONTROLS SIGNAGE MUST BE MOUNTED ON THE WALL ADJACENT TO LATCH SIDE OF DOOR. WHERE THERE IS NO WALL SPACE TO THE LATCH SIDE OF THE DOOR, SIGNAGE MUST BE PLACED ON THE NEAREST ADJACENT WALL. MOUNTING HEIGHT MUST BE 60" A.F.F. TO THE CENTERLINE OF SIGN. SIGNS CONTAINING TACTILE CHARACTERS MUST HAVE AN 18" MIN. BY 18" MIN. CLEAR FLOOR SPACE, CENTERED ON THE SIGN, BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND A 45 DEGREE OPEN POSITION. TACTILE EXIT SIGNS: A TACTILE SIGN STATING "EXIT" AND COMPLYING WITH ICC/ANSI A117.1 CHAPTER 7 MUST BE PROVIDED ADJACENT TO EACH DOOR TO AN EGRESS STAIRWAY, AN EXIT PASSAGEWAY AND THE EXIT DISCHARGE. ACCESSIBLE SIGNAGE: ALL REQUIRED ACCESSIBLE ELEMENTS MUST BE IDENTIFIED BY THE INTERNATIONAL SYMBOL OF ACCESSIBILITY AT THE FOLLOWING LOCATIONS: 1. ACCESSIBLE PARKING SPACES. 2. ACCESSIBLE PASSENGER LOADING ZONES. 3. ACCESSIBLE UNISEX TOILET AND BATHING ROOMS. 4. ACCESSIBLE ENTRANCES WHERE NOT ALL ENTRANCES ARE ACCESSIBLE. 5. ACCESSIBLE CHECK-OUT AISLES WHERE NOT ALL AISLES ARE ACCESSIBLE. 6. FAMILY OR ASSISTED-USE TOILET AND BATHING ROOMS. 7. ACCESSIBLE DRESSING, FITTING AND LOCKER ROOMS WHERE NOT ALL SUCH ROOMS ARE ACCESSIBLE. 8. ACCESSIBLE AREAS OF REFUGE. 9. EXTERIOR AREAS FOR ASSISTED RESCUE. A TACTILE SIGN MUST BE PROVIDED AT ALL LOCATIONS WHERE PICTORIAL SIGNAGE IS USED TO LABEL PERMANENT ROOMS OR SPACES (I.E. RESTROOMS), COMPLYING WITH ICC/ANSI A117.1 CHAPTER 7 AND MUST BE PROVIDED ADJACENT TO EACH DOOR. OCCUPANT LOAD SIGNAGE: EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY MUST HAVE THE OCCUPANT LOAD OF THE ROOM OR SPACE POSTED NEAR THE MAIN EXIT. DRAWING NUMBER DRAWING TITLE KEY PLAN ARCHITECTS AND PLANNERS 550 E. NINE MILE ROAD FERNDALE, MICHIGAN, 48220 PHONE 248.543.4100 FAX 248.543.4141 FUSCO, SHAFFER & PAPPAS, INC. COPYRIGHT 2021 - FUSCO, SHAFFER & PAPPAS, INC. FSP PROJECT NO. DATE ISSUE SEAL CODE ANALYSIS A.C.001 ATW20.072B COLORADOFOOTHILLSMAIL BUILDINGSUN COMMUNITIESFORT COLLINSSCALE:1/4" = 1'-0"A.C.001 CODE ANALYSIS1 OCCUPANT LOAD CALCULATIONS ROOM NAME AREA AREA PER OCCUPANT OCCUPANT LOAD 100 MAIL BUILDING 180 SF 100 SF 2 TOTAL OCCUPANT LOAD 2 02.18.2022 PERMIT 06.15.2022 CITY COMMENTS A.201 3 7 MAILBOX EACH END - SEE SPECIFICATIONS 2'-0" 5'-10" 2'-0" A.201 1 A.2012 A.201 4 6 A.101 3" 9'-10" 3" ELECTRICAL 1 A B 2 3"2'-0" 24'-6"10'-4"8'-6"201 6 A.701 A.101 7 10'-4"22'-0"EQ 2'-8" 2'-8" EQEQ EQ10'-4"A.101 5 2 3 4 MAILBOX - SEE SPECIFICATIONS 202 WALL LEGEND: CMU WALL **NOTE: WALL LEGEND SHOWN FOR GRAPHICAL REFERENCE ONLY. REFER TO WALL TYPES AND SECTIONS FOR ADDITIONAL DETAILS AND INFORMATION. 1. UTILIZE 8"x8"x16" CONCRETE MASONRY UNITS FOR WALLS. SEE STRUCTURAL FOR GROUTING & REINFORCEMENT REQUIREMENTS. 2. VERIFY SIZE AND LOCATION OF MECHANICAL AND ELECTRICAL EQUIPMENT, PADS, PENETRATIONS AND SUPPORTS WITH MECHANICAL AND ELECTRICAL DRAWINGS. 3. COORDINATE ALL METER LOCATIONS WITH CIVIL, PLUMBING AND ELECTRICAL DRAWINGS. GENERAL PLAN NOTES: BOTT. OF FOUNDATION GRADE FIRST FLOOR8"3'-4"A B A.701 5 2 12 6 A.701 T.O.S - LOW1'-5"9'-0"T.O.S - HIGH 1 B 8X8 STEEL COLUMN ON METAL BASE PLATE- SEE STRUCTURAL 8" CMU WALL W/ HORIZONTAL & VERTICAL STEEL REINFORCING 8 A.101 MANUFACTURED STONE VENEER 9 A.101 1 9 A.101 4"B 8 A.101 THRU WALL MEMBRANE FLASHING MANUFACTURED STONE VENEER ON MORTAR SETTING BED ON MORTAR SCRATCH COAT WITH LATH ON CMU WALL DRIP EDGE 4" LIMESTONE CAP 8"X8" STEEL COLUMN W/ STEEL BASE PLATE & ANCHOR BOLTS INTO BLOCK 4"3/8" BACKER ROD & SEALANT A B6 A.701 201 6 A.1011 2 MAILBOX W/ DEPOT BASE STANDING SEAM METAL ROOF MANUFACTURED STONE ON MASONRY WALL AB STANDING SEAM METAL ROOF MANUFACTURED STONE ON MASONRY WALL ALUMINUM STOREFRONT MAILBOX W/ DEPOT BASE 202 6 A.101 12 MAILBOX W/ DEPOT BASE STANDING SEAM METAL ROOF DRAWING NUMBER DRAWING TITLE KEY PLAN ARCHITECTS AND PLANNERS 550 E. NINE MILE ROAD FERNDALE, MICHIGAN, 48220 PHONE 248.543.4100 FAX 248.543.4141 FUSCO, SHAFFER & PAPPAS, INC. COPYRIGHT 2021 - FUSCO, SHAFFER & PAPPAS, INC. FSP PROJECT NO. DATE ISSUE SEAL OVERALL BUILDING PLAN, REFLECTED CEILING PLAN, AND INTERIOR ELEVATIONS A.101 ATW20.072B COLORADOFOOTHILLSMAIL BUILDINGSUN COMMUNITIESFORT COLLINSSCALE:1/4" = 1'-0"A.101 FIRST FLOOR PLAN1 TRUE NORTH SCALE:1/4" = 1'-0"A.101 INTERIOR ELEVATION6 SCALE:1" = 1'-0"A.101 ENLARGED DETAIL7 SCALE:1" = 1'-0"A.101 SECTION THRU STONE CAP8 SCALE:1" = 1'-0"A.101 SECTION THRU STONE CAP9 SCALE:1/4" = 1'-0"A.101 INTERIOR ELEVATION2 SCALE:1/4" = 1'-0"A.101 INTERIOR ELEVATION3 SCALE:1/4" = 1'-0"A.101 INTERIOR ELEVATION4 SCALE:1/4" = 1'-0"A.101 INTERIOR ELEVATION5 02.18.2022 PERMIT 06.15.2022 CITY COMMENTS ICE AND WATER SHIELD ROOF PLAN LEGEND OUTLINE OF EXTERIOR WALL STANDING SEAM ROOF NOTES 1. 2. ROOF DETAILS ARE SCHEMATIC. PLEASE REFER TO MANUFACTURER'S RECOMMENDATIONS AND SPECIFIC PRODUCT LITERATURE FOR ACCEPTABLE MATERIALS, ACCESSORIES AND INSTALLATION PROCEDURES. INSTALL ICE AND WATER SHIELD OVER ENTIRE ROOF. 1 A B 2 2:12ICE AND WATER SHIELD OVER ENTIRE ROOF 6 A.701 1. THIS PLAN IS INTENDED TO SHOW GENERAL COORDINATION OF OVERHEAD WORK. REFER TO STRUCTURAL, PLUMBING, MECHANICAL & ELECTRICAL DRAWINGS FOR FURTHER INFORMATION. 2. ALL CEILING HEIGHTS ARE APPROXIMATE FINISH DIMENSIONS, FIELD VERIFY. REFLECTED CEILING PLAN NOTES: SYMBOL DESCRIPTION REFLECTED CEILING PLAN SYMBOLS LEGEND WATERPROOF LED DOWNLIGHT SOFFIT VENT 6 A.101 1 A B 2 6 A.701 1'-8"5'-4" 10'-8" 6'-0" 1'-8" 22'-0" 8" 2'-11" ROOM FINISH NOTES GENERAL NOTES: • SEE BUILDING AND WALL SECTIONS FOR ADDITIONAL CEILING HEIGHT INFORMATION. • REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL FINISHES NOT LISTED IN THE ROOM FINISH SCHEDULE. DRAWING NUMBER DRAWING TITLE KEY PLAN ARCHITECTS AND PLANNERS 550 E. NINE MILE ROAD FERNDALE, MICHIGAN, 48220 PHONE 248.543.4100 FAX 248.543.4141 FUSCO, SHAFFER & PAPPAS, INC. COPYRIGHT 2021 - FUSCO, SHAFFER & PAPPAS, INC. FSP PROJECT NO. DATE ISSUE SEAL ROOF PLAN AND DETAILS A.109 ATW20.072B COLORADOFOOTHILLSMAIL BUILDINGSUN COMMUNITIESFORT COLLINSTRUE NORTH SCALE:1/4" = 1'-0"A.109 ROOF PLAN1 SCALE:1/4" = 1'-0"A.109 REFLECTED CEILING PLAN3 TRUE NORTH ROOM FINISH SCHEDULE RM NO. ROOM NAME FLOOR BASE WALL CEILING CEILING PAINT / FINISH NOTESFINISH FINISH MATERIAL MATERIAL HEIGHT WALL CEILING 100 MAIL BUILDING STAINED CONCRETE CMU VARIES (STONE AND CMU) WOOD PANELS VARIES CMU PORCH BOARD 02.18.2022 PERMIT 06.15.2022 CITY COMMENTS BOTT. OF FOUNDATION GRADE FIRST FLOOR STANDING SEAM METAL ROOF 6 A.101 3'-4"8"12 6'-8"MANUFACTURED STONE VENEER 4" STONE CAP ALUMINUM WRAPPED 1X6 FASCIA BOARD T.O.S - LOW 9'-0"T.O.S - HIGH ELECTRIC PANEL AND DISCONNECT BOTT. OF FOUNDATION GRADE FIRST FLOOR 6 A.101 1 2 8"3'-4"1/4" METAL PLATE W/ POWDER COAT FINISH PIN MOUNTED TO MANUFACTURED STONE VENEER WALL6'-8"2'-6"5'-0"3'-3"3'-0"3'-3"5'-0"2'-6" T.O.S - LOW 9'-0"T.O.S - HIGH 22'-0" PIN MOUNTED BULLETIN BOARD & DIRECTORY MANUFACTURED STONE VENEER 4" STONE CAP ALUMINUM WRAPPED 1X6 FASCIA BOARD INSULATED GLAZING IN ALUMINUM STOREFRONT FRAMING VERIFY DESIGN BOTT. OF FOUNDATION GRADE FIRST FLOOR AB 201 MIN.4'-0"2'-0"7'-0"4"DIRECTORY SIGN HSS 8X8X1/4 COLUMN 6 A.701 T.O.S - LOW T.O.S - HIGH ALUMINUM WRAPPED 1X6 FASCIA BOARD STANDING SEAM METAL ROOF ON 3" METAL DECK MANUFACTURED STONE VENEER INSULATED GLAZING IN ALUMINUM STOREFRONT SYSTEM LIGHT FIXTURE PORCH BOARD SOFFIT BOTT. OF FOUNDATION GRADE FIRST FLOOR A B 4'-0"2'-0"4"6'-8"8"3'-4"STANDING SEAM METAL ROOF 2 12 8X8X1/4 COLUMN ALUMINUM WRAPPED 1X6 FASCIA BOARD MANUFACTURED STONE VENEER 6 A.701 8X8X3/8 BEAM (TYP.)T.O.S - LOW 9'-0"T.O.S - HIGH 202 GENERAL ELEVATION NOTES 1. CAULK AND SEAL ALL PENETRATIONS, GAPS, SPACES, JOINTS, OPENINGS, DOORS AND WINDOWS, ETC AT ENTIRE EXTERIOR OF BUILDING, CAULK AND SEALANT TO MATCH ADJACENT SIDING AND/OR BRICK FINISH. DRAWING NUMBER DRAWING TITLE KEY PLAN ARCHITECTS AND PLANNERS 550 E. NINE MILE ROAD FERNDALE, MICHIGAN, 48220 PHONE 248.543.4100 FAX 248.543.4141 FUSCO, SHAFFER & PAPPAS, INC. COPYRIGHT 2021 - FUSCO, SHAFFER & PAPPAS, INC. FSP PROJECT NO. DATE ISSUE SEAL OVERALL BUILDING ELEVATIONS A.201 ATW20.072B COLORADOFOOTHILLSMAIL BUILDINGSUN COMMUNITIESFORT COLLINSSCALE:1/4" = 1'-0"A.201 ELEVATION3 SCALE: 1/4" = 1'-0"A.201 ELEVATION1 SCALE:1/4" = 1'-0"A.201 ELEVATION2 SCALE: 1/4" = 1'-0"A.201 ELEVATION4 02.18.2022 PERMIT 06.15.2022 CITY COMMENTS PPODFWDLO5 1/2"2 3/4"4 1/2" AA WIDTH DOOR ALUMINUM STOREFRONT FRAMING 2"2"DOOR HEIGHT2"ALUMINUM DOOR W/GLAZING A DOOR WIDTH DOOR HEIGHT10"1/2" EXPANSION JOINT MATERIAL W/ SEALANT BARRIER FREE THRESHOLD SET IN MASTIC EXTERIOR ALUMINUM DOOR ALUMINUM FRAME INSULATED GLAZING SLOPE 2% MAX STONE VENEER SEALANT W/ BACKER ROD 5" SUPPORTED CONCRETE SLAB W/ REINFORCEMENT (SEE STRUCTURAL) ON 1" GALV. METAL DECK ON 2" MIN. VOID SPACE VOID SPACE COMPACTED GRANULAR FILL 7 5/8" 4 1/2"SIDELITE - SEE FRAME TYPESD.O. SEE SCHEDULE2"ALUMINUM FRAME INSULATED GLAZING ALUMINUM DOOR WITH INSULATED GLAZING SIDELITE - SEE FRAME TYPESSIDELITE - SEE FRAME TYPES2"ALUMINUM FRAME INSULATED GLAZING INSULATED GLAZING 4 1/2" WINDOW TO DOOR DETAIL WINDOW TO WINDOW DETAIL SILL ANCHORS W/ VERTICAL REINFORCEMENT SEALANT @ENTIRE PERIMETER -BOTH SIDES ALUMINUM FRAME W/ SILL REINFORCEMENT SIDELITE -SEE FRAME TYPESFOUNDATION CONCRETE SLAB 1/2" EXPANSION JOINT MATERIAL W/ SEALANT SLOPE 2% MAX MANUFACTURED STONE VENEER BEYOND 6"4 1/2" INSULATED GLAZING SEALANT W/ BACKER ROD 5" SUPPORTED CONCRETE SLAB W/ REINFORCEMENT (SEE STRUCTURAL) ON 1" GALV. METAL DECK ON 2" MIN. VOID SPACE VOID SPACE COMPACTED GRANULAR FILL BOTT. OF FOUNDATION GRADE FIRST FLOOR A 9'-0"8"3'-4"T.O.S - LOW 4"6'-8"4'-0"MANUFACTURED STONE VENEER ON MORTAR SETTING BED ON MORTAR SCRATCH COAT WITH LATH ON 8" C.M.U WITH HORIZONTAL LADDER REINFORCING 16" OC. VERTICAL - SEE STRUCTURAL HSS 8X8X3/8 STEEL BEAM, SEE STRUCTURAL PAINT EXPOSED CONCRETE BLOCK TO MATCH STONE VENEER FINISH MAILBOX TYP., SEE SPECS FOR MOUNTING HEIGHTS REQUIREMENTSSECURE MAILBOX CABINETS TO BLOCK WALL AS NEEDED GROUT SOLID BELOW FLASHING 5" CONCRETE SLAB WITH WWF STEEL REINFORCING, VAPOR BARRIER AND 4" COMPACTED BASE, SEE STRUCTURAL 1/2" EXPANSION JOINT STAINLESS STEEL METAL SCREED SET IN SEALANT FLASHING ALUMINUM WRAPPED 1x6 FASCIA BOARD METAL STANDING SEAM ROOF CEMENT PORCH BOARD ON 3/4" PLYWOOD ON METAL DECK HSS 8X8X3/8 STRUCTURAL BEAM, SEE STRUCTURAL RECESSED LIGHTING WITH JUNCTION BOX METAL SHIMMING 1 1/2" 1 1/2" DRIP EDGE BOND BEAM -SEE STRUCTURAL BOTT. OF FOUNDATION GRADE FIRST FLOOR 2 3'-4" 8" A.701 1 A.701 2 COMPACTED GRANULAR FILL EXPOSED CONCRETE MASONRY COURSE, PAINT TO MATCH STONE VENEER HSS 8X8X3/8 BEAM, SEE STRUCTURAL MAIL BOX CABINET (TYP.) SEE SPECS FOR MOUNTING REQUIREMENTS MANUFACTURED STONE VENEER ALUMINUM DOOR AND FRAME, SEE SCHEDULE INSULATED GLAZING 4" STONE CAP SLOPE 2% MAX 5" SUPPORTED CONCRETE SLAB W/ STEEL REINFORCEMENT (SEE STRUCTURAL) ON 1" GALV. METAL DECK ON 2" MIN. VOID SPACE 5" CONCRETE SLAB WITH WWF STEEL REINFORCING, VAPOR BARRIER AND 4" COMPACTED BASE, SEE STRUCTURAL L2 1/2X 2 1/2 X 1/4 STIFFENERS (TYP.) STANDING SEAM METAL ROOF ON 3" METAL DECK ALUMINUM WRAPPED 1X6 FASCIA BOARD RECESSED LED WITH 2" JUNCTION BOX CEMENT PORCH BOARD ON 3/4" PLYWOOD ON METAL DECK NOTCH STONE CAP TO FIT AROUND STOREFRONT 1/2" EXPANSION JOINT GLAZING NOTES A. GLAZING AT ALL EXTERIOR DOORS, SIDELITES AND FIXED LITES MUST BE INSULATED SAFETY GLAZING. • ALL MEANS OF EGRESS DOORS SHALL BE READILY OPERABLE FROM EGRESS SIDE WITHOUT KEY OR SPECIAL KNOWLEDGE. • G.C. TO CONFIRM HAND OF ALL DOORS. • WEATHERSTRIPPING ON ALL EXTERIOR DOORS. • GC TO COORDINATE ROUGH OPENING REQUIREMENTS WITH MANUFACTURER PRIOR TO CONSTRUCTION. • EXTERIOR DOORS TO HAVE INSULATED GLAZING. DOOR AND HARDWARE GENERAL NOTES EYE ANCHORS WITH 4" PINS AT JOINTS DRIP EDGE THRU WALL FLASHING S LOP E 4" STONE CAP BOND BEAM - SEE STRUCTURAL MANUFACTURED STONE VENEER ON MORTAR SETTING ON MORTAR SCRATCH COAT WITH METAL LATH ON 8" CMU WALL 1/2" PRESSURE TREATED WOOD SHIM BACKER ROD & SEALANTS ALUMINUM SILL SECTION GLAZING SHIM, BACKER ROD AND SEALANT @ ENTIRE PERIMETER -BOTH SIDES ALUMINUM FRAME MANUFACTURED STONE VENEER ALUMINUM RECEIVER 2 1/2"4 1/2" PRESSURE TREATED 2X4 SECURED TO BLOCK ALUMINUM STOREFRONT 2 1/2"1/2" 8" MASONRY WALL 1/2" MORTAR SCRATCH COAT W/ EXPANDED METAL LATH BACKER ROD & SEALANT HARDWARE SET "A": 1 EA. PULL 1 EA. PUSH PAD 1 EA CLOSER 1 EA GASKETS 1 EA CONTINUOUS HINGE DRAWING NUMBER DRAWING TITLE KEY PLAN ARCHITECTS AND PLANNERS 550 E. NINE MILE ROAD FERNDALE, MICHIGAN, 48220 PHONE 248.543.4100 FAX 248.543.4141 FUSCO, SHAFFER & PAPPAS, INC. COPYRIGHT 2021 - FUSCO, SHAFFER & PAPPAS, INC. FSP PROJECT NO. DATE ISSUE SEAL DOOR AND ROOM FINISH SCHEDULE A.701 ATW20.072B COLORADOFOOTHILLSMAIL BUILDINGSUN COMMUNITIESFORT COLLINSDOOR SCHEDULE DOOR OR LITE NO. DOOR FRAME HARD WARE FIRE RATING NOTES SIZE TYPE MAT'L DETAILS TYPE MAT'L LABEL / HRS.W H T HEAD JAMB SILL SHEET 201 3'-0" 7'-0" 1 3/4" A ALUM. 2 1 A.701 A ALUMINUM 22 - 202 3'-0" 7'-0" 1 3/4" A ALUM. 2 1 A.701 A ALUMINUM 22 - SCALE:1 1/2" = 1'-0"A.701 ALUMINUM DOOR SILL DETAIL1DOOR TYPES1/4" = 1'-0"FRAME TYPES1/4" = 1'-0"SCALE:1 1/2" = 1'-0"A.701 ALUM. STOREFRONT INTERMEDIATE DETAILS2 SCALE:1 1/2" = 1'-0"A.701 SIDELITE ALUMINUM STOREFRONT SILL4 SCALE:1" = 1'-0"A.701 WALL SECTION5 SCALE:1" = 1'-0"A.701 WALL SECTION6 SCALE:1 1/2" = 1'-0"A.701 DETAIL AT STONE SILL9 SCALE:1 1/2" = 1'-0"A.701 ALUM. STOREFRONT JAMB3 02.18.2022 PERMIT 06.15.2022 CITY COMMENTS