HomeMy WebLinkAboutAPEX-HAVEN - FDP210012 - SUBMITTAL DOCUMENTS - ROUND 3 - RESPONSE TO STAFF REVIEW COMMENTS Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6689 970.224.6134  fax fcgov.com/developmentreview June 30, 2021 Shelley La Mastra Russell + Mills Studios 506 S College Ave Unit A Fort Collins, CO 80524 RE: Apex  Haven Apartments, FDP210012, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of Apex  Haven Apartments. If you have questions about any comments, you may contact the individual commenter or direct your questions through your Development Review Coordinator, Brandy Bethurem Harras via phone at 9704162744 or via email at bbethuremharras@fcgov.com. Comment Summary: Department: Development Review Coordinator Contact: Brandy Bethurem Harras, 9704162744, bbethuremharras@fcgov.com Topic: General Comment Number: 1 05/04/2021: INFORMATION: I will be your primary point of contact throughout the development review and permitting process. If you have any questions, need additional meetings with the project reviewers, or need assistance throughout the process, please let me know and I can assist you and your team. Please include me in all email correspondence with other reviewers and keep me informed of any phone conversations. Thank you! RMS Response: Thank you. Comment Number: 7 05/04/2021: FOR FINAL APPROVAL: All "For Final Approval / For Approval" comments need to be addressed and resolved prior to moving forward with the final documents and recording of this project. I will provide a recording checklist and process information when we are closer to this step. RMS Response: Thank you, we will cc you on emails so you are aware when we have final sign off from all departments. Comment Number: 6 05/04/2021: INFORMATION: LUC 2.211 Lapse, Term of Vested Right: Within a maximum of three (3) years following the approval of a final plan or other site specific development plan, the applicant must undertake, install and complete all engineering improvements (water, sewer, streets, curb, gutter, street lights, fire hydrants and storm drainage) in accordance with city codes, rules and regulations. The period of time shall constitute the "term of the vested property right." Failure to undertake and complete such engineering improvements within the term of the vested property right shall cause a forfeiture of the vested property right and shall require resubmission of all materials and reapproval of the same to be processed as required by this Code. All dedications as contained on the final plat shall remain valid unless vacated in accordance with law. RMS Response: Noted, thank you. Department: Planning Services Contact: Pete Wray, 9702216754, pwray@fcgov.com Topic: General Comment Number: 2 06/16/2021: FOR APPROVAL: Ready for Recording RMS Response: Noted, thank you. Department: Historic Preservation Contact: Maren Bzdek, 9702216206, mbzdek@fcgov.com Topic: General Comment Number: 1 05/25/2021: Please submit a finalized plan of protection document for review at your earliest convenience. ALM2s Response: The plan of protection was submitted on November 15, 2021 and approved by Maren Bzdek on 12/9/21 via email. Department: Forestry Contact: Nils Saha, , nsaha@fcgov.com Topic: General Comment Number: 3 6/29/2021: FOR FINAL APPROVAL: The symbols for shade trees on LP100 and LP101 do not match (the gingko and the discovery elm symbols are switched). Please make sure they are consistent. RMS Response: Symbols have been corrected. Department: Engineering Development Review Contact: Spencer Smith, 9702216603, smsmith@fcgov.com Topic: General Comment Number: 1 06/29/2021: DEVELOPMENT AGREEMENT  UPDATED: Thank you for submitting the DA information form. The DA draft will be sent to our City Attorney for review in the next couple of days. I will provide a draft for review by the applicant team once it is ready. RMS Response: Noted, thank you. 05/24/2021: DEVELOPMENT AGREEMENT: A development agreement (DA) will be required for this project. Please complete and submit a development agreement information form (included in the comments/redlines for this submittal). I will need this in order to prepare the draft agreement. I will try and get a draft DA ready for review by our City Attorney by the time we issue comments on your next submittal. Once our attorney has reviewed the agreement, the draft will be provided to you for review. The DA will need to be completed prior to final approval. For more information on development agreements, please visit the City Development Review Engineering website: https://www.fcgov.com/engineering/devrev.php RMS Response: Previous comment. Comment Number: 2 06/29/2021: DEVELOPMENT CONSTRUCTION PERMIT  UPDATED: Thank you for submitting the cost estimate. It has been routed to our Chief Engineering Inspector for review. I will coordinate with you if there are any questions or revisions required. United Civil Response: Noted, thank you. 05/24/2021: DEVELOPMENT CONSTRUCTION PERMIT: A development construction permit (DCP) will be required prior to commencing construction of any public improvements. Once the plans are close to approval, we will need an engineer's opinion of cost submitted by the consulting engineer (licensed in CO). This cost estimate will be reviewed by Engineering and Engineering Inspections staff. Once approved, it will serve as the basis for Engineering inspection fees as well as public improvement surety that will be required prior to DCP issuance. For more information on the DCP process, requirements and cost estimate template, visit the City Development Review Engineering website: https://www.fcgov.com/engineering/devrev.php United Civil Response: Previous comment. Comment Number: 5 06/29/2021: FOR FINAL APPROVAL  UPDATED: You added a note on the plan about the connection but didn't see the detail that was referenced. United Civil Response: The construction joint detail is shown in the CDOT concrete pavement joint detail on sheet C6.03. The note on sheet C4.02 has been further clarified noting to use a construction joint with doweled connection. 05/24/2021: FOR FINAL APPROVAL: How is the proposed concrete being tied into the existing concrete of the emergency access drive on the north side of the site? Please ensure that you are providing the necessary detail for the installation. I assume you would dowel the sections together, similar to a connection to an existing section of sidewalk. United Civil Response: Previous comment. Department: Light And Power Contact: Cody Snowdon, 9704162306, csnowdon@fcgov.com Topic: General Comment Number: 1 06/29/2021: FOR FINAL APPROVAL: Please work with Light and Power on the grading of the transformer pad to avoid exceed 4:1 side slopes. United Civil Response: Grading has been revised. 05/13/2021: FOR APPROVAL: The proposed transformer will need to be installed on a level surface. Please show the revised grading around the proposed location. This may require a wall to ensure detention volume is achieved. United Civil Response: Previous comment. Comment Number: 2 05/13/2021: FOR DCP: A commercial service information form (C1 form) and a oneline diagram for all commercial meters will need to be completed and submitted to Light & Power Engineering for review prior to Final Plan. A link to the C1 form is below: http://zeus.fcgov.com/utilsprocedures/files/EngWiki/WikiPdfs/C/C1Form.pdf ALM2s Response: A C-1 form will be issued once the project is submittal for permit review. Comment Number: 3 05/13/2021: FOR DCP: On the oneline diagram, please show the main disconnect size and meter sequencing. A copy of our meter sequencing can be found in our electric policies practices and procedures below. http://www.fcgov.com/utilities/business/buildersanddevelopers/developmentfo rmsguidelinesregulations ALM2s Response: The final one-line diagram will be submitted when the project is submitted for permit review. Department: Technical Services Contact: Jeff County, 9702216588, jcounty@fcgov.com Topic: Construction Drawings Comment Number: 5 06/29/2021: FOR FINAL APPROVALUNRESOLVED: The Benchmark Statement on sheet C0.01 does not match the cover sheet. All Benchmark Statements must match on all sheets. United Civil Response: Addressed. 05/25/2021: FOR FINAL APPROVAL: Please provide the following information for the Benchmark Statement in the EXACT format shown below. PROJECT DATUM: NAVD88 BENCHMARK # w/ DESCRIPTION ELEVATION: BENCHMARK # w/ DESCRIPTION ELEVATION: PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 DATUM  X.XX’. United Civil Response: Previous comment. Topic: Plat Comment Number: 1 06/29/2021: FOR FINAL APPROVALUPDATED: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. Washburn Response: Changes made. Department: Outside Agencies Contact: Megan Harrity, Larimer County Office of the Assessor, mharrity@larimer.org, 9704987065, , Topic: General Comment Number: 1 06/29/2021: FOR FINAL APPROVAL  UNRESOLVED: No change was shown on the resubmittal, no response to this comment was provided. Washburn Response: Titles matched. 05/17/2021: FOR FINAL APPROVAL: The title and the statement do not match. The Statement of Subdivision description is stated as: to be known as Apex/Haven Property. The Plat Title is ApexHaven Apartments. These should be the same. Department: Water Conservation Contact: Eric Olson, 9702216704, eolson@fcgov.com Topic: General Comment Number: 1 05/24/2021: BUILDING PERMIT: Irrigation plans are required no later than at the time of building permit. The irrigation plans must comply with the provisions outlined in Section 3.2.1(J) of the Land Use Code. Direct questions concerning irrigation requirements to Eric Olson, at 2216704 or eolson@fcgov.com RMS Response: Irrigation plans have been sent. Additional water meter has been added per new code requirement. Department: Building Services Contact: Russell Hovland, 9704162341, rhovland@fcgov.com Topic: Building Insp Plan Review Comment Number: 1 05/21/2021: BUILDING PERMIT: The multifamily building is closer than 10ft to the north property line and will require a 1hour wall and limited openings. all buildings should have a fire separation distance of 20ft between them. ALM2s Response: The north wall is designed to be 1-hour rated and includes limited openings. Comment Number: 2 05/21/2021: BUILDING PERMIT: Construction shall comply with adopted codes as amended. Current adopted codes are: 2018 International Building Code (IBC) with local amendments 2018 International Existing Building Code (IEBC) with local amendments 2018 International Energy Conservation Code (IECC) with local amendments 2018 International Mechanical Code (IMC) with local amendments 2018 International Fuel Gas Code (IFGC) with local amendments 2018 International Swimming Pool and Spa Code (ISPSC) with local amendments 2018 International Plumbing Code (IPC) as amended by the State of Colorado 2020 National Electrical Code (NEC) as amended by the State of Colorado Copies of current City of Fort Collins code amendments can be found at fcgov.com/building. Accessibility: State Law CRS 95 & ICC/ANSI A117.12017. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Loads: Risk Category II (most structures): · 140mph (Ultimate) exposure B or · Front Range Gust Map published by The Structural Engineer's Association of   Seismic Design: Category B. Climate Zone: Zone 5 Energy Code: · Multifamily and Condominiums 3 stories max: 2018 IECC residential chapter. · Commercial and Multifamily 4 stories and taller: 2018 IECC commercial chapter.  INFORMATIONAL ITEMS: · 10% of all parking spaces must be EV ready (conduit in place) · This building is located within 250ft of a 4 lane road or 1000 ft of an active railway, must provide exterior composite sound transmission of 39 STC min. · R2 occupancies must provide 10ft setback from property line and 20 feet between other buildings or provide fire rated walls and openings per chapter 6 and 7 of the IBC. · City of Fort Collins amendments to the 2018 IBC require a full NFPA13 sprinkler system in multifamily units with an exception to allow NFPA 13R systems in buildings with no more than 6 dwelling units (or no more than 12 dwelling units where the building is divided by a 2 hour fire barrier with no more than 6 dwelling units on each side). · Bedroom egress windows required below 4th floor regardless of firesprinkler. All egress windows above the 1st floor require minimum sill height of 24”. · Prescriptive energy compliance with increased insulation values is required for buildings using electric heat. · A City licensed commercial general contractor is required to construct any new multifamily structure. ALM2s Response: Comments Acknowledged. The project will be submitted per permit under the currently adopted 2021 I-Codes. Additional comments: Since the last round of review the lighting and irrigation requirements have changed. The plans have been updated to reflect new code requirements. 2